SUN主机维护手册
- 格式:pdf
- 大小:246.91 KB
- 文档页数:26
系统操作维护文档1、Cluster的操作l 查看Cluster状态:使用hastat命令来查看# hostnameChina168-1# hastatGetting Information from all the nodes ......HIGH A V AILABILITY CONFIGURATION AND STATUS------------------------------------------LISTOF NODES CONFIGURED IN <China168> CLUSTERChina168-1 China168-2CURRENT MEMBERS OF THE CLUSTERChina168-1 is a cluster memberChina168-2 is a cluster memberCONFIGURATION STATE OF THE CLUSTERConfiguration State on China168-1: StableConfiguration State on China168-2: StableUPTIME OF NODES IN THE CLUSTERuptime of China168-1: 3:17pm up 1 day(s), 2:30, 3 users, load average: 0.13, 0.41, 0.50uptime of China168-2: 3:18pm up 1 day(s), 2:30, 3 users, load average: 0.08, 0.18, 0.24LOGICAL HOSTS MASTERED BY THE CLUSTER MEMBERS Logical Hosts Mastered on China168-1:NoneLogical Hosts for which China168-1 is Backup Node:NoneLogical Hosts Mastered on China168-2:NoneLogical Hosts for which China168-2 is Backup Node:NoneLOGICAL HOSTS IN MAINTENANCE STA TENoneSTA TUS OF PRIV ATE NETS IN THE CLUSTERStatus of Interconnects on China168-1:interconnect0: selectedinterconnect1: upStatus of private nets on China168-1:To China168-1 - UPTo China168-2 - UPStatus of Interconnects on China168-2:interconnect0: selected interconnect1: upStatus of private nets on China168-2:To China168-1 - UPTo China168-2 - UPSTA TUS OF PUBLIC NETS IN THE CLUSTERStatus of Public Network On China168-1:bkggrp r_adp status fo_time live_adpnafo0 hme0:hme1 OK 89755 hme1Status of Public Network On China168-2:bkggrp r_adp status fo_time live_adpnafo0 hme0:hme1 OK NEVER hme0…………………….我们可以看到上面红字的部分,它表示现在两台机器都是Cluster的成员。
SUN硬件系统安装及管理维护手册目录一,Sun X4600服务器安装及维护 (3)1.1 X4600服务器硬件设置及维护管理 (3)1.2在X4600服务器上安装RHEL5.2操作系统 (7)二,Sun STK6140存储阵列安装及维护 (16)2.1 STK6140磁盘阵列硬件安装 (16)2.2 STK6140磁盘阵列管理与维护设置 (17)三,SUN SL48自动磁带库安装及维护 (25)3.1 SL48磁带库安装 (25)3.2 SL48维护管理设定 (27)四,Oracle 10g数据库安装 (28)4.1 安装基本信息 (28)4.2 安装前准备工作 (28)4.3 安装ORACLE 10G (10.2.0.1版本)数据库系统 (31)五,VCS双机热备软件安装及日常维护 (41)5.1 VCS 5.0双机热备软件安装 (41)5.2 VCS软件日常管理 (43)六,NETBACKUP自动备份软件安装及日常维护 (48)6.1 NETBACKUP备份软件安装 (48)6.2 Netbackup软件日常管理 (55)七,系统开关机流程 (57)7.1系统关机流程 (57)7.2 系统开机流程 (57)一Sun X4600服务器安装及维护1.1 X4600服务器硬件设置及维护管理SUN X4600服务器背后示意图:服务器连接方式:SUN X4600服务器有二种人机界面连接方式:➢显示器/键盘/鼠标管理➢ILOM管理(有串行口和网络口两种管理途径)各接口部位如上图所示,对于支持无显示器操作的操作系统,键盘、鼠标和视频显示器是可选件。
安装在机柜中的服务器,可以采用网络管理口进行远程管理。
网络管理IP设置:如上图所示,标注"NET 0" 至"NET 3" 的连接器为10/100/1000 千兆位以太网端口。
标注"NET MGT" (网络管理)的端口为10/100 以太网端口,用于将系统连接到一个管理网络。
Sun T5220服务器维护指南一、配置T5220服务器SC利用PC 终端配置T5220服务器的SC(System Controller)。
设置SC 只需要在第一次安装的时候进行,后续不再需要重新设置。
1 用串口线连接SC 的串口和PC 终端的串口。
串口线一头是RJ-45 接口,插入SC 的串口(Serial Mgt Port)。
Km 带外管理。
图1 SC口位置表1 SC与PC终端的串口线线序标准表2 设置串口的属性值2 在超级终端窗口中,当系统提示以下信息时,输入用户名root。
SUNSP00144F970053 login:3 当系统提示以下信息时,输入root用户的密码changeme。
4 执行以下命令,还原ILOM 设置的默认值。
-> set /SP reset_to_defaults=all5 执行以下命令,重启ILOM。
-> reset /SP当系统提示以下信息时,输入y。
Are you sure you want to reset /SP (y/n)? y6 当系统再次提示以下信息时,输入用户名root。
SUNSP00144F970053 login:7 当系统提示以下信息时,输入root用户的密码changeme。
8执行以下命令,创建admin用户,以启动ALOM。
-> create /SP/users/admin role=Administrator cli_mode=alom9设置admin用户密码。
说明请根据规划输入用户密码admin123。
Creating user...Enter new password: ********Enter new password again: ********Created /SP/users/admin10执行以下命令,检查用户创建是否成功。
-> show /SP/users/SP/usersTargets:rootadmin如果回显信息中有admin用户,则说明用户已成功创建;否则,请执行步骤8和步骤9重新创建admin用户。
华为技术有限公司SUN2000-(70KTL,75KTL)-C1快速指南文档版本:09部件编码:31509024发布日期:2023-03-131指示灯说明机箱正面(1)PV 连接指示灯(2)并网指示灯(3)通信指示灯(4)告警/维护指示灯(5)维护腔门(6)主机面板指示灯状态含义PV 连接指示灯绿灯亮光伏组串中至少一路连接正常,并且对应MPPT 电路的直流输入电压大于等于200V 。
绿灯灭逆变器与所有光伏组串均断连,或所有MPPT 电路的直流输入电压均小于200V 。
并网指示灯绿灯亮逆变器处于并网状态。
绿灯灭逆变器未并网。
通信指示灯绿灯闪(0.2s 亮,0.2s 灭)逆变器正常接收到通信数据。
绿灯灭逆变器持续10s 未接收到通信数据。
1.由于产品版本升级或其他原因,本文档内容会不定期进行更新。
除非另有约定,本文档仅作为使用指导,文档中的所有陈述、信息和建议不构成任何明示或暗示的担保。
2.安装设备前请详细阅读用户手册,了解产品信息及安全注意事项。
3.设备所有操作必须由训练有素的专业电气技术人员进行。
操作人员应充分熟悉整个光伏并网发电系统的构成、工作原理,及项目所在国家/地区的相关标准。
4.安装设备前请根据《装箱清单》检查交付件是否完整齐备,有无任何明显的外部损坏。
如果缺少任何物件或存在任何损坏,请联系您的经销商。
5.安装设备时必须使用绝缘工具。
为了人身安全,请佩戴个人防护用品。
6.未按照本文档与用户手册的内容存储、搬运、安装和使用设备而导致设备损坏,不在设备质保范围内。
端口说明指示灯状态含义告警/维护指示灯告警状态红灯慢闪(1s 亮,4s 灭)逆变器出现提示告警。
红灯快闪(0.5s 亮,0.5s 灭)逆变器出现次要告警。
红灯常亮逆变器出现重要告警。
近端维护状态绿灯慢闪(1s 亮,1s 灭)近端维护中。
绿灯快闪(0.125s 亮,0.125s 灭)近端维护失败。
绿灯常亮近端维护成功。
机箱尺寸工程安装件尺寸(1)防水接头(COM1/COM2/COM3)(3)直流输入端子(由DC SWITCH 1控制)(5)直流开关2(DC SWITCH 2)(7)防水接头(RESERVE )(2)直流开关1(DC SWITCH 1)(4)直流输入端子(由DC SWITCH 2控制)(6)防水接头(AC OUTPUT )(8)USB 接口(USB)2安装角度2.1安装空间2.2为了便于将逆变器安装到工程安装件上,同时为了便于逆变器底部接线和后续维护,建议600mm ≤ 底部空间≤ 730mm 。
SUN日常维护手册Sun日常维护手册(v 20131108)版本说明目录目录版本说明 (2)一、机房环境检查 (6)1.机房温度 (6)2.机房湿度 (6)3.机房洁净度 (6)二、主机硬件运行情况检查 (7)1.主机状态灯检查 (7)1.1 SUN SPARC Server Front Panel LEDs (7) 1.2 SUN SPARC Server Rear Panel LEDs (8)1.3 SUN SPARC Server Disk Drive LEDs (9)2、主机硬件配置及运行状态检查 (9)2.1 CPU配置检查 (9)2.2 内存配置检查 (10)2.3 内置硬盘配置检查 (12)2.4 网卡配置检查 (13)2.5 风扇情况检查 (15)2.6 系统日志检查 (16)三、存储设备运行情况检查 (17)1.Sun StorEdge A1000系列 (17)2.Sun StorEdge 3510系列 (17) 3.Sun StorageTek 6140系列 (18) 四、Solaris操作系统运行状态检查 (21) 1.操作系统版本 (21)2.文件系统类型 (22)2.1 UFS (Unix File system) (23)2.2 VXFS (Veritas File System) (23) 2.3 ZFS (Zettabyte File System) (24) 3.卷管理和数据镜像 (25)3.1 SVM卷管理 (25)3.2 VXVM卷管理 (27)3.3 ZFS卷管理 (30)4.多路径检查 (30)4.1 多路径配置文件 (30)4.2 多路径状态检查 (31)5.系统性能运行检查 (31)5.1 CPU使用情况检查 (31)5.2 内存使用情况检查 (32)5.3 I/O使用情况检查 (34)五、双机Cluster运行状态检查 (35)1. Sun Cluster (35)2. Veritas Cluster (39)六、故障诊断信息收集 (42) 1.Power-On Self Test (POST) (42) 2.Sun Explorer (43)七、日常维护周期策略 (43)1.日维护内容 (43)1.1 机房环境 (43)1.2 硬件状态 (46)1.3 系统状态 (47)1.4 集群状态 (49)1.5 性能和安全 (49)1.6 磁盘阵列存储状态 (51)2.周维护内容 (52)2.1 机房环境 (52)2.2 硬件状态 (52)2.3 系统状态 (53)2.4 集群状态 (53)2.5 性能和安全 (53)2.6 补丁 (53)2.7 磁盘阵列存储状态 (53)3.月维护内容 (55)3.1 机房环境 (55)3.2 硬件状态 (55)3.3 系统状态 (55)3.4 集群状态 (55)3.5 性能和安全 (55)3.6 补丁 (55)3.7 磁盘阵列存储状态 (56)八、附录 (56)8.1. ILOM巡检指导v1.0 (56)8.2. XSCF 巡检操作指导v1.0 (58)8.2 SC 巡检操作指导v1.0 (64)一、机房环境检查机房的温度,湿度和洁净度是否合理,将会直接影响到设备的正常运作,如果机房的温度过高,湿度过于干燥,灰尘过多的话将会直接影响设备的使用寿命,因此平时对机房的健康和检查也是必不可少的。
SUN系统维护命令大全1、查看机型:SUn的小型机的机型都在面板上写着有,如NETRA T 1125,还有比如utra 5,utra 10等等。
2、查看cpu个数(错误,不正确,因为sun中的top命令不能完全看到所有的cpu情况,与HP用法也不一样)#topCPU states: 99.3% idle, 0.1% user, 0.6% kernel, 0.0% iowait, 0.0% swap表示只有一个cpu正确方法:用dmesg |grep cpu便可以看到正确的cpu个数了。
3、查看内存#dmesg |grep memmem = 2097152K (0x80000000)avail mem = 20877393924、查看磁盘的个数#vxdisk listDEVICE TYPE DISK GROUP STATUSc0t0d0s2 sliced - - errorc0t0d0s7 simple c0t0d0s7 rootdg onlinec1t0d0s2 sliced - - onlinec1t1d0s2 sliced smpdg2 smpdg onlinec1t2d0s2 sliced smpdbdg1 smpdbdg onlinec2t0d0s2 sliced - - onlinec2t1d0s2 sliced smpdg1 smpdg onlinec2t2d0s2 sliced smpdbdg2 smpdbdg online5、如何查看文件系统#df -kFilesystem kbytes used avail capacity Mounted on/dev/dsk/c0t0d0s0 4032142 1050675 2941146 27% //proc 0 0 0 0% /procfd 0 0 0 0% /dev/fd/dev/dsk/c0t0d0s6 7304977 29 7231899 1% /home/dev/dsk/c0t0d0s5 4032142 402929 3588892 11% /optswap 3418392 32 3418360 1% /tmp/vol/dev/dsk/c0t6d0/informix201730 201730 0 100% /cdrom/informix/dev/vx/dsk/smpdg/smpdg-stat1055 9 941 1% /smpwork/dev/vx/dsk/smpdg/lv_smp17336570 128079 17035126 1% /sms6、查看卷组、逻辑卷的位置#cd /dev/vx/dsk/比如smpdg等等都在该目录下了,然后再进入某个卷组目录就可以看到该卷组下面的逻辑卷了。
SUN2000-(50KTL,50KTL-C1)用户手册文档版本 Draft A 发布日期2016-01-30华为技术有限公司版权所有© 华为技术有限公司2016。
保留一切权利。
非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本文档内容的部分或全部,并不得以任何形式传播。
商标声明和其他华为商标均为华为技术有限公司的商标。
本文档提及的其他所有商标或注册商标,由各自的所有人拥有。
注意您购买的产品、服务或特性等应受华为公司商业合同和条款的约束,本文档中描述的全部或部分产品、服务或特性可能不在您的购买或使用范围之内。
除非合同另有约定,华为公司对本文档内容不做任何明示或默示的声明或保证。
由于产品版本升级或其他原因,本文档内容会不定期进行更新。
除非另有约定,本文档仅作为使用指导,本文档中的所有陈述、信息和建议不构成任何明示或暗示的担保。
华为技术有限公司地址:深圳市龙岗区坂田华为总部办公楼邮编:518129网址:客户服务邮箱:support@客户服务电话:4008302118前言概述本文档主要介绍了SUN2000-50KTL/50KTL-C1(后文简称SUN2000)的安装、电气连接、调试、维护和故障处理的方法。
请在安装、使用逆变器之前,认真阅读本手册,了解安全信息并熟悉逆变器的功能和特点。
读者对象本手册适用于光伏电站操作人员及具备相应资质的电气技术人员。
符号约定在本文中可能出现下列标志,它们所代表的含义如下。
修改记录修改记录累积了每次文档更新的说明。
最新版本的文档包含以前所有文档版本的更新内容。
文档版本Draft A (2016-01-30)试验局版本。
目录前言 (ii)1 安全注意事项 (1)2 产品介绍 (3)2.1 产品简介 (3)2.2 外观说明 (4)2.3 标签说明 (8)2.4 工作原理 (10)3 逆变器存储 (12)4 系统安装 (13)4.1 安装前检查 (13)4.2 准备安装工具 (13)4.3 挂墙安装 (17)4.3.1 选择安装位置 (17)4.3.2 搬运逆变器 (22)4.3.3 安装工程安装件 (23)4.3.4 安装逆变器 (26)4.4 支架安装 (29)4.4.1 选择安装位置 (29)4.4.2 搬运逆变器 (32)4.4.3 安装工程安装件 (32)4.4.4 安装逆变器 (34)5 电气连接 (35)5.1 开维护腔门 (35)5.2 连接保护地线(PE) (36)5.3 连接交流输出线 (38)5.4 连接直流输入线 (42)5.5 连接通信线 (48)5.5.1 通信方式说明 (48)5.5.2 连接RS485通信线 (49)5.6 关维护腔门 (55)6 系统调试 (57)6.1 上电前检查 (57)6.2 系统上电 (57)6.3 系统下电 (58)7 系统维护 (59)7.1 日常维护 (59)7.2 故障处理 (60)8 逆变器处置 (65)8.1 拆卸逆变器 (65)8.2 包装逆变器 (65)8.3 报废逆变器 (65)9 技术数据 (66)A 缩略语 (69)1 安全注意事项人员要求●所有针对SUN2000的操作必须由训练有素的专业电气技术人员进行。
Sun StorEdge 3000 系列安装、操作和维护手册Sun StorEdge 3510 FC 阵列Sun Microsystems, Inc.4150 Network CircleSanta Clara, CA 95054 U.S.A.650-960-1300部件号 817-2760-102003 年 3 月,修订版 A请将对本文档的意见发送到:*******************版权所有 © 2002-2003 Dot Hill Systems Corporation, 6305 El Camino Real, Carlsbad, California 92009, USA.保留所有权利。
Sun Microsystems, Inc. 和 Dot Hill Corporation 可能拥有与本产品或文档中涉及的技术相关的知识产权。
具体来说(且不仅限于此),这些知识产权包括 /patents 所列出的美国专利中的一项或多项,以及在美国或其他国家(地区)申请的一项或多项补充专利或未决专利。
本产品或文档按照限制其使用、复制、分发和反编译的许可证进行分发。
本产品或文档的任何部分,未经 Sun 及其许可方(如果有)的事先书面授权,不得以任何形式或任何手段加以复制。
第三方软件由 Sun 供应商提供版权及许可授权。
本产品的某些部分来源于 Berkeley BSD 系统,已获得 University of California 的许可。
UNIX 是在美国和其他国家(地区)的注册商标,已通过 X/Open Company, Ltd. 获得独家许可。
Sun、Sun Microsystems、Sun 标志、Sun StorEdge、AnswerBook2、, 和 Solaris 是 Sun Microsystems, Inc. 在美国和其他国家(地区)的商标或注册商标。
美国政府权利 ó 商业使用。
技术文档(v 101010)作者王卫锋审核分类Sun 子类Cluster更新时间2010-10-10关键字Solaris 10,Sun Cluster 3.2摘要Sun Cluster 3.2 日常维护主要适Solaris 10,Sun Cluster 3.2用环境版本说明拟制/修改责任人拟制/修改日期修改内容/理由版本号V101010 王卫锋2010-10-10 新建目录版本说明 (2)1 系统和软硬件环境说明 (3)2 Cluster状态查看命令 (3)3 Cluster各节点状态查看 (7)4 Cluster 资源组详细信息 (8)5 Cluster资源详细信息 (10)6 Cluster did设备信息 (12)7 Cluster资源组切换命令 (13)8 Cluster devicegroup信息查看 (13)1 系统和软硬件环境说明硬件环境:Sun SPARC主机软件环境:Solaris 10,Sun Cluster 3.22 Cluster状态查看命令root@M5000-1A # scstat (cluster状态查看命令)-------------------------------------------------------------------- Cluster Nodes --Node name Status--------- ------Cluster node: M5000-1B OnlineCluster node: M5000-1A Online-------------------------------------------------------------------- Cluster Transport Paths --Endpoint Endpoint Status-------- -------- ------ Transport path: M5000-1B:bge3 M5000-1A:bge3 Path online Transport path: M5000-1B:bge1 M5000-1A:bge1 Path online-------------------------------------------------------------------- Quorum Summary from latest node reconfiguration --Quorum votes possible: 3Quorum votes needed: 2Quorum votes present: 3-- Quorum Votes by Node (current status) --Node Name Present Possible Status--------- ------- -------- ------Node votes: M5000-1B 1 1 OnlineNode votes: M5000-1A 1 1 Online-- Quorum Votes by Device (current status) --Device Name Present Possible Status----------- ------- -------- ------Device votes: /dev/did/rdsk/d19s2 1 1 Online-------------------------------------------------------------------- Device Group Servers --Device Group Primary Secondary------------ ------- ---------Device group servers: sybiqdb M5000-1B M5000-1A Device group servers: sybfs M5000-1B M5000-1A Device group servers: syb1bak M5000-1A M5000-1B-- Device Group Status --Device Group Status------------ ------Device group status: sybiqdb OnlineDevice group status: sybfs OnlineDevice group status: syb1bak Online-- Multi-owner Device Groups --Device Group Online Status------------ --------------------------------------------------------------------------------- Resource Groups and Resources --Group Name Resources---------- ---------Resources: sybiq-rg sybiq-lh-rs sybiq-hastp-rs sybfs-hastp-rs sybaseiq Resources: t2kfs-rg t2kfs-lh-rs zxt2000-- Resource Groups --Group Name Node Name State Suspended---------- --------- ----- --------- Group: sybiq-rg M5000-1B Online NoGroup: sybiq-rg M5000-1A Offline NoGroup: t2kfs-rg M5000-1A Online NoGroup: t2kfs-rg M5000-1B Offline No-- Resources --Resource Name Node Name State Status Message------------- --------- ----- --------------Resource: sybiq-lh-rs M5000-1B Online Online - LogicalHostname online. Resource: sybiq-lh-rs M5000-1A Offline Offline - LogicalHostname offline.Resource: sybiq-hastp-rs M5000-1B Online OnlineResource: sybiq-hastp-rs M5000-1A Offline OfflineResource: sybfs-hastp-rs M5000-1B Online OnlineResource: sybfs-hastp-rs M5000-1A Offline OfflineResource: sybaseiq M5000-1B Online OnlineResource: sybaseiq M5000-1A Offline OfflineResource: t2kfs-lh-rs M5000-1A Online Online - LogicalHostname online. Resource: t2kfs-lh-rs M5000-1B Offline Offline - LogicalHostname offline.Resource: zxt2000 M5000-1A Online OnlineResource: zxt2000 M5000-1B Offline Offline-------------------------------------------------------------------- IPMP Groups --Node Name Group Status Adapter Status--------- ----- ------ ------- ------IPMP Group: M5000-1B ipmp Online bge2 OnlineIPMP Group: M5000-1B ipmp Online bge0 OnlineIPMP Group: M5000-1A ipmp Online bge2 OnlineIPMP Group: M5000-1A ipmp Online bge0 Online-- IPMP Groups in Zones --Zone Name Group Status Adapter Status--------- ----- ------ ------- ------------------------------------------------------------------------root@M5000-1A #Quorum devices查看root@M5000-1A # scstat –q (cluster Quorum devices查看)-- Quorum Summary from latest node reconfiguration --(两节点的cluster的Quorum devices一定要是3)Quorum votes possible: 3Quorum votes needed: 2Quorum votes present: 3-- Quorum Votes by Node (current status) --Node Name Present Possible Status--------- ------- -------- ------Node votes: M5000-1B 1 1 OnlineNode votes: M5000-1A 1 1 Online-- Quorum Votes by Device (current status) --Device Name Present Possible Status----------- ------- -------- ------Device votes: /dev/did/rdsk/d19s2 1 1 Online3 Cluster各节点状态查看root@M5000-1A # clnode show (cluster各节点状态查看)=== Cluster Nodes ===Node Name: M5000-1BNode ID: 1Enabled: yesprivatehostname: clusternode1-privreboot_on_path_failure: disabledglobalzoneshares: 1defaultpsetmin: 1quorum_vote: 1quorum_defaultvote: 1quorum_resv_key: 0x4B877D3700000001Transport Adapter List: bge1, bge3Node Name: M5000-1ANode ID: 2Enabled: yesprivatehostname: clusternode2-privreboot_on_path_failure: disabledglobalzoneshares: 1defaultpsetmin: 1quorum_vote: 1quorum_defaultvote: 1quorum_resv_key: 0x4B877D3700000002 Transport Adapter List: bge1, bge34 Cluster 资源组详细信息root@M5000-1A # clrg show=== Resource Groups and Resources ===Resource Group: sybiq-rgRG_description: <NULL>RG_mode: FailoverRG_state: ManagedFailback: FalseNodelist: M5000-1B M5000-1A--- Resources for Group sybiq-rg ---Resource: sybiq-lh-rsType: SUNW.LogicalHostname:2Type_version: 2Group: sybiq-rgR_description:Resource_project_name: defaultEnabled{M5000-1B}: TrueEnabled{M5000-1A}: TrueMonitored{M5000-1B}: TrueMonitored{M5000-1A}: TrueResource: sybiq-hastp-rsType: SUNW.HAStoragePlus:8Type_version: 8Group: sybiq-rgR_description:Resource_project_name: defaultEnabled{M5000-1B}: TrueEnabled{M5000-1A}: TrueMonitored{M5000-1B}: TrueMonitored{M5000-1A}: TrueResource: sybfs-hastp-rsType: SUNW.HAStoragePlus:8 Type_version: 8Group: sybiq-rgR_description:Resource_project_name: defaultEnabled{M5000-1B}: TrueEnabled{M5000-1A}: TrueMonitored{M5000-1B}: TrueMonitored{M5000-1A}: TrueResource: sybaseiqType: Sybase.IQ:1.0Type_version: 1.0Group: sybiq-rgR_description:Resource_project_name: defaultEnabled{M5000-1B}: TrueEnabled{M5000-1A}: TrueMonitored{M5000-1B}: TrueMonitored{M5000-1A}: TrueResource Group: t2kfs-rgRG_description: <NULL>RG_mode: FailoverRG_state: ManagedFailback: FalseNodelist: M5000-1A M5000-1B--- Resources for Group t2kfs-rg ---Resource: t2kfs-lh-rsType: SUNW.LogicalHostname:2 Type_version: 2Group: t2kfs-rgR_description:Resource_project_name: defaultEnabled{M5000-1A}: TrueEnabled{M5000-1B}: TrueMonitored{M5000-1A}: TrueMonitored{M5000-1B}: TrueResource: zxt2000Type: ZTE.Zxt2000:1.0Type_version: 1.0Group: t2kfs-rgR_description:Resource_project_name: defaultEnabled{M5000-1A}: TrueEnabled{M5000-1B}: TrueMonitored{M5000-1A}: TrueMonitored{M5000-1B}: Trueroot@M5000-1A # clrg list (cluster 资源组列表)sybiq-rgt2kfs-rg5 Cluster资源详细信息root@M5000-1A # clrs list (cluster 资源列表)sybiq-lh-rssybiq-hastp-rssybfs-hastp-rssybaseiqt2kfs-lh-rszxt2000root@M5000-1A # clrs show (cluster 资源详细信息)=== Resources ===Resource: sybiq-lh-rsType: SUNW.LogicalHostname:2Type_version: 2Group: sybiq-rgR_description:Resource_project_name: defaultEnabled{M5000-1B}: TrueEnabled{M5000-1A}: TrueMonitored{M5000-1B}: TrueMonitored{M5000-1A}: TrueResource: sybiq-hastp-rsType: SUNW.HAStoragePlus:8 Type_version: 8Group: sybiq-rgR_description:Resource_project_name: defaultEnabled{M5000-1B}: TrueEnabled{M5000-1A}: TrueMonitored{M5000-1B}: TrueMonitored{M5000-1A}: TrueResource: sybfs-hastp-rsType: SUNW.HAStoragePlus:8 Type_version: 8Group: sybiq-rgR_description:Resource_project_name: defaultEnabled{M5000-1B}: TrueEnabled{M5000-1A}: TrueMonitored{M5000-1B}: TrueMonitored{M5000-1A}: TrueResource: sybaseiqType: Sybase.IQ:1.0Type_version: 1.0Group: sybiq-rgR_description:Resource_project_name: defaultEnabled{M5000-1B}: TrueEnabled{M5000-1A}: TrueMonitored{M5000-1B}: TrueMonitored{M5000-1A}: TrueResource: t2kfs-lh-rsType: SUNW.LogicalHostname:2 Type_version: 2Group: t2kfs-rgR_description:Resource_project_name: defaultEnabled{M5000-1A}: TrueEnabled{M5000-1B}: TrueMonitored{M5000-1A}: TrueMonitored{M5000-1B}: TrueResource: zxt2000Type: ZTE.Zxt2000:1.0Type_version: 1.0Group: t2kfs-rgR_description:Resource_project_name: defaultEnabled{M5000-1A}: TrueEnabled{M5000-1B}: TrueMonitored{M5000-1A}: TrueMonitored{M5000-1B}: True6 Cluster did设备信息root@M5000-1A # scdidadm –L (cluster did设备列表)1 M5000-1B:/dev/rdsk/c0t0d0 /dev/did/rdsk/d12 M5000-1B:/dev/rdsk/c0t1d0 /dev/did/rdsk/d23 M5000-1B:/dev/rdsk/c0t3d0 /dev/did/rdsk/d34 M5000-1B:/dev/rdsk/c1t0d0 /dev/did/rdsk/d45 M5000-1B:/dev/rdsk/c1t1d0 /dev/did/rdsk/d56 M5000-1B:/dev/rdsk/c2t201400A0B8485330d31 /dev/did/rdsk/d66 M5000-1A:/dev/rdsk/c2t201400A0B8485330d31 /dev/did/rdsk/d67 M5000-1B:/dev/rdsk/c4t201500A0B8485330d31 /dev/did/rdsk/d77 M5000-1A:/dev/rdsk/c4t201500A0B8485330d31 /dev/did/rdsk/d78 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA0000033Fd0 /dev/did/rdsk/d89 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA0000023Cd0 /dev/did/rdsk/d910 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA00000233d0 /dev/did/rdsk/d1011 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA0000022Ad0 /dev/did/rdsk/d1112 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA00000042d0 /dev/did/rdsk/d1212 M5000-1A:/dev/rdsk/c6t60060E800571FA00000071FA00000042d0 /dev/did/rdsk/d1213 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA0000003Bd0 /dev/did/rdsk/d1313 M5000-1A:/dev/rdsk/c6t60060E800571FA00000071FA0000003Bd0 /dev/did/rdsk/d1314 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA00000033d0 /dev/did/rdsk/d1414 M5000-1A:/dev/rdsk/c6t60060E800571FA00000071FA00000033d0 /dev/did/rdsk/d1415 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA0000002Bd0 /dev/did/rdsk/d1515 M5000-1A:/dev/rdsk/c6t60060E800571FA00000071FA0000002Bd0 /dev/did/rdsk/d1516 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA00000023d0 /dev/did/rdsk/d1616 M5000-1A:/dev/rdsk/c6t60060E800571FA00000071FA00000023d0 /dev/did/rdsk/d1617 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA0000001Cd0 /dev/did/rdsk/d1717 M5000-1A:/dev/rdsk/c6t60060E800571FA00000071FA0000001Cd0 /dev/did/rdsk/d1718 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA00000014d0 /dev/did/rdsk/d1818 M5000-1A:/dev/rdsk/c6t60060E800571FA00000071FA00000014d0 /dev/did/rdsk/d1819 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA0000000Ad0 /dev/did/rdsk/d1919 M5000-1A:/dev/rdsk/c6t60060E800571FA00000071FA0000000Ad0 /dev/did/rdsk/d1920 M5000-1B:/dev/rdsk/c6t60060E800571FA00000071FA00000000d0 /dev/did/rdsk/d2020 M5000-1A:/dev/rdsk/c6t60060E800571FA00000071FA00000000d0 /dev/did/rdsk/d2021 M5000-1A:/dev/rdsk/c0t0d0 /dev/did/rdsk/d2122 M5000-1A:/dev/rdsk/c0t1d0 /dev/did/rdsk/d2223 M5000-1A:/dev/rdsk/c1t0d0 /dev/did/rdsk/d2324 M5000-1A:/dev/rdsk/c1t1d0 /dev/did/rdsk/d247 Cluster资源组切换命令root@M5000-1A # scswitch -z -g t2kfs-rg -h M5000-1B (cluster 资源组切换命令,示例为将资源组t2kfs-rg切换至M5000-1B上运行)8 Cluster devicegroup信息查看root@M5000-1A # cldg list (cluster device group 列表)syb1baksybfssybiqdbroot@M5000-1A # cldg show (cluster device group 详细信息)=== Device Groups ===Device Group Name: syb1bakType: SVMfailback: falseNode List: M5000-1A, M5000-1Bpreferenced: truenumsecondaries: 1diskset name: syb1bakDevice Group Name: sybfsType: SVMfailback: falseNode List: M5000-1A, M5000-1B preferenced: true numsecondaries: 1diskset name: sybfsDevice Group Name: sybiqdbType: SVMfailback: falseNode List: M5000-1A, M5000-1B preferenced: true numsecondaries: 1diskset name: sybiqdb。
一、主机加电通电前确认主机、磁阵的主、备电源均已插好。
主机加电的时候,需要打开前面板,按蓝色的On/Standby开关,通电后主机会进行自检,引导solaris操作系统。
二、启动VCS软件1、先检查HACMP状态:#ps –ef|grep had查看vcs守护进程#hastatus -summ查看VCS服务组和资源#hagui &图形管理界面2、查看网络及diskgroup状态#vxdg list查看diskgroup是否被激活,正常状态下diskgroup应该由HA来进行激活#ifconfig –a 查看IP是否正常3、启动HA软件在主机启动过程中,会自动启动VCS进程tail –f /var/VRTSvcs/log/engine_A.log打开HA启动日志#hagui 图示HA状态(只有在主控端才能显示图形界面)#ifconfig -a查看服务IP是否已经生效#vxdg list查看VG是否被HA激活#df –k 查看文件系统是否已经被挂接4、关闭(切换)HAhastop -local停止当前节点HAhastop –all 停止所有接点HA三、日常维护操作oslevel –r查看当前AIX版本及补丁级别df –k检查文件系统状态,是否有使用率在80%以上的文件系统smitty chjfs2改变文件系统大小(慎用)/var/adm/messages查看错误日志errpt –a|more查看错误日志详细信息errpt –a >/tmp/2005-04-05errpt.out将当前错误日志详细信息保存至指定位置mail查看有无系统报错通知lppchk –v查看是否少文件包,如无输出则为正常vxprint -ht查看物理卷磁盘信息format查看逻辑磁盘信息四、对7133-D40的操作在有的情况下,会在共享VG上添加新的逻辑卷,这时需要做以下的同步操作。
1、假设无双机情况下,在node1上给共享VG添加了lv,此时共享Vg的状态是激活的(可用lsvg –o查看)。
Sun M4000/M5000服务器维护指南一、配置M4000/M5000服务器XSCF1、串口线一头是RJ-45 接口,插入XSCF 的串行端口。
图1 串行端口位置表1 串行端口线缆线序表2设置串口的属性值2、将操作面板上的钥匙设置到“维修”位置。
3、在超级终端窗口中,当系统提示以下信息时,输入用户名default。
login:4、当系统提示以下信息时,将操作面板上的钥匙设置到“锁定”位置,然后按“Enter”。
Change the panel mode switch to Locked and press return...5、当系统提示以下信息时,将操作面板上的钥匙设置到“维修”位置,等待5秒以上,然后按“Enter”。
Leave it in that position for at least 5 seconds. Change the panel mode switch to Service, and press return...6、执行以下命令,还原XSCF 设置的默认值。
还原出厂设置过程中,当系统提示输入[yes/no]的时候,一律输入yes。
XSCF> restoredefaults -c factory7、当系统提示以下信息时,XSCF 将会自动重启。
Please stand by while rebooting the system.(15)Restarting system8、当系统再次提示以下信息时,输入用户名default。
login:9、当系统提示以下信息时,将操作面板上的钥匙设置到“锁定”位置,然后按“Enter”。
Change the panel mode switch to Locked and press return...10、当系统提示以下信息时,将操作面板上的钥匙设置到“维修”位置,等待5秒以上,然后按“Enter”。
Leave it in that position for at least 5 seconds. Change the panel mode switch toService, and press return...11、执行以下命令,创建adminuser用户。
切换办法:平台shell 进入非活动域:SC 主机名:SC> console -d a注:如果OpenBoot PROM 处于ok 提示符状态下,或者Solaris 操作环境处于login: 提示符状态下,请按Enter 键查看提示。
否则,将需要等待POST、OpenBoot PROM 或Solaris 操作环境生成的输出。
如果域被挂起,则将没有输出。
但是,当域没有显示输出时,不一定意味着域被挂起。
域切换到平台:disconnect;从域控制台进入域Shell:#.从域shell进入域控制台:resume如果域处于非活动状态,请在域shell 中键入以下命令来激活和初始化域:SC 主机名:A> setkeyswitch on处理方案:1、对备机,连接SC板;前面板SC板;SC0或者SC1;2、键入showboards 命令及-a 选项,查找可在域中使用的板。
3、关机:root# init 0okok CTRL ]telnet> send breakSC 主机名:A>SC 主机名:A> setkeyswitch offSC 主机名:A> disconnect4、从sc平台中删除需要移走的板子:SC 主机名:SC> deleteboard sbx5、SC 主机名:SC> addboard -d a sb x6、进入域:SC 主机名:SC> console -d a键入showboards 命令及-a 选项,查找可在域中使用的板。
7、启动域:SC 主机名:C> setkeyswitch on▼查找包含域永久内存的系统板●识别包含永久内存的板# cfgadm -val | grep permanent▼取消配置包含永久内存的系统板1. 识别包含永久内存的板。
# cfgadm -val | grep permanent2. 取消配置包含永久内存的板。
SUN小型机故障处理指导书目录第1章故障的定义 (1)第1章故障信息的收集 (1)1.1控制台信息 (1)1.2系统故障记录(MESSAGES) (1)1.3主机面板上的LED (2)1.4系统引导的故障记录 (2)1.5MAIL (3)1.6运行故障诊断程序(PRTDIAD -V)对系统硬件进行检查和诊断(3)1.7其他用于收集系统信息的命令 (4)第2章硬件故障定位方法 (1)2.1PROM (1)2.2系统的启动顺序 (1)2.3系统引导的时候,发生停止 (1)2.4系统DUMP (2)第3章软件故障定位方法 (1)3.1文件系统空间不够 (1)3.2检查文件系统的完整性 (2)第4章常用的系统状态查询命令 (1)第5章网络故障定位方法 (1)5.1网络不通的诊断过程 (1)5.2网络配置的基本方法 (1)第6章SUN CLUS TER环境下的排错 (1)6.1了解问题的存在 (1)6.2判断问题的出处 (1)第1章故障的定义根据以下这些方面来考虑故障定位:●弄清楚系统发生了什么问题●系统现在能做什么不能做什么●故障什么时候发生的●有没有做平时不同的操作●故障有没有规律定时还是不定时发生的频率有多高●是一台机器出现故障还是多台机器故障故障现象是否相同●最近有没有做改动如安装了新的硬件软件改变了系统的一些设置第1章故障信息的收集收集故障信息对于判断诊断故障原因修复系统非常重要1.1 控制台信息通过系统控制台来收集系统的信息,系统启动时的硬件自检信息,系统日常运行时的信息。
如:Sun Fire 480R, No KeyboardCopyright 1998-2002 Sun Microsystems, Inc. All rights reserved.OpenBoot 4.7.5, 4096 MB memory installed, Serial #54021334.Ethernet address 0:3:ba:38:4c:d6, Host ID: 83384cd6.Rebooting with command:bootBoot device:/pci@9,600000/SUNW,qlc@2/fp@0,0/disk@w21000004cfd 98e33,0:a Fileand args:SunOS Release 5.8 Version Generic_117350-18 64-bitCopyright 1983-2003 Sun Microsystems, Inc. All rights reserved.Starting VxVM restore daemon...VxVM starting in boot mode.../usr/sbin/prtconf: getexecname() failedvxvm:vxconfigd: NOTICE: atf vendor_info: readlink fails for/dev/rdsk/c2t1d0s2: No such file or directoryNOTICE: vxvm:vxdmp: added disk array OTHER_DISKS, datype =OTHER_DISKSvxvm:vxconfigd: NOTICE: Unable to resolve duplicate diskid.Please refer to release notes and admin guide for possible action/solution.Following are the disks with duplicate diskid:Vendor: SEAGATE Product: ST336607FSUN36G - c1t1d0s2, c1t0d0s2vxvm:vxconfigd: WARNING: Detaching plex rootvol-01 from volumerootvolvxvm:vxconfigd: ERROR: Cannot start rootvol volume, no valid plexesvxvm:vxconfigd: ERROR: System startup failedsyncing file systems... doneProgram terminated1.2 系统故障记录(messages)syslog 进程在系统启动时自动运行。
Sun Microsystems, 將您對此文件的意見傳送到:/hwdocs/feedbackNetra ™ 210 Server 維修手冊文件號碼:819-5939-102006 年 3 月,修訂版 A請回收Copyright 2006 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. 版權所有。
Sun Microsystems, Inc. 對於本文件所述技術擁有智慧財產權。
這些智慧財產權包含 /patents 上所列的一項或多項美國專利,以及在美國與其他國家/地區擁有的一項或多項其他專利或申請中專利,但並不以此為限。
本文件及相關產品在限制其使用、複製、發行及反編譯的授權下發行。
未經 Sun 及其授權人 (如果有) 事先的書面許可,不得使用任何方法、任何形式來複製本產品或文件的任何部分。
協力廠商軟體,包含字型技術,其版權歸 Sun 供應商所有,經授權後使用。
本產品中的某些部分可能源自加州大學授權的 Berkeley BSD 系統的開發成果。
UNIX 是在美國及其他國家/地區的註冊商標,已獲得 X/Open Company, Ltd. 專屬授權。
Sun 、Sun Microsystems 、Sun 標誌、Java 、AnswerBook2、Netra 、 及 Solaris 為 Sun Microsystems, Inc. 在美國及其他國家/地區的商標或註冊商標。
所有 SPARC 商標都是 SPARC International, Inc. 在美國及其他國家/地區的商標或註冊商標,經授權後使用。
凡具有 SPARC 商標的產品都是採用 Sun Microsystems, Inc. 所開發的架構。
OPEN LOOK 與 Sun™ Graphical User Interface (Sun 圖形化使用者介面) 都是由 Sun Microsystems,Inc. 為其使用者與授權者所開發的技術。
目 录1 操作系统维护 (1)1.1 系统启动与关闭 (1)1.2 定期检查系统空间使用情况 (2)1.3 定期检查系统的日志 (3)1.4 定期察看mail (3)1.5 安全管理 (3)1.6 系统运行状态的监控 (4)1.7 设备管理 (9)1.8 软件管理 (11)1.9 进程管理 (14)1.10 磁盘管理 (15)1.10.1 系统目录 (15)1.10.2 逻辑分区操作的常用命令 (15)1.10.3 文件系统管理 (16)1.11 系统备份 (21)2 VCS集群管理 (22)2.1 VCS的启动 (22)2.2 VCS的停止 (22)3 数据库常用操作命令 (23)3.1 数据库启停 (23)3.2 数据库用户管理 (23)3.3 数据库存储管理 (23)3.4 简单的数据库备份操作 (24)4 日常维护注意事项 (25)1操作系统维护1.1 系统启动与关闭a.系统启动开机后,系统将自检所有的设备,一旦系统无法开机,应及时通知工程师进行故障检测及处理。
b.系统关闭系统关闭命令可以使用shutdown、init、halt等命令,但建议使用shutdown 或init命令进行关机操作。
注:尽量不要使用halt命令关闭主机。
z重启主机#shutdown –i init_state(run level 6 for reboot) –g grace_period#init 6z关闭主机#shoutdown –i 0#init 0z关闭主机进入单用户状态#shutdown#init s/Sz查看当前运行级别who -r1.2 定期检查系统空间使用情况a.定时使用df –k命令检查文件系统磁盘空间的使用情况。
# df -kFilesystem kbytes used avail capacity Mounted on /dev/dsk/c0t0d0s0 75204 41148 26536 61% //dev/dsk/c0t0d0s4 1244382 595010 587153 51% /usr/proc 0 0 0 0% /procfd 0 0 0 0% /dev/fdmnttab 0 0 0 0% /etc/mnttab /dev/dsk/c0t0d0s6 121096 10393 98594 10% /varswap 460120 0 460120 0% /var/run swap 539592 79472 460120 15% /tmp/dev/dsk/c0t0d0s3 2060642 954065 1044758 48% /opt/dev/dsk/c0t0d0s5 9450 9 8496 1% /temp/dev/dsk/c0t0d0s7 61484 9 55327 1%/export/homeb.删除Crash Dump文件# cd /var/crash/system# rm *c.删除Core文件# cd /home/jones# find . -name core -exec rm {} \;d.定期清除/tmp文件系统中没用的临时文件# cd /var/tmp# rm -r *e.删除不再用的旧文件# find directory-type f[-atime +nnn] [-mtime +nnn] -print >filename # rm `cat filename`1.3 定期检查系统的日志# more /var/adm/syslog/syslog.log1.4 定期察看mail系统的错误和告警信息会同时发送到控制台和用户的mail中。
由于屏幕刷新,在控制台上的信息可能会漏看,可在用户mail中看到。
使用如下命令即可看到出现的一些错误信息或提示信息:# mail1.5 安全管理应由专人管理系统和数据库口令,定期修改root、oracle系统用户和数据库sys、system的口令。
管理用户的telnet和rlogin权限。
用last察看最近用户的登录和退出,该信息记录在/var/adm/wtmp可以使用如下命令查看登录到系统的用户信息:#who1.6 系统运行状态的监控在系统运行过程中,系统管理人员应该定时对系统运行情况和性能进行分析,协助数据库管理员及应用程序开发人员进行应用跟踪分析,提高系统性能。
a.使用vmstat察看CPU,虚拟内存的使用情况。
$ vmstat 5procs memory page disk faults cpur b w swap free re mf pi po fr de sr f0 s3 -- -- in sy cs us sy id0 0 8 28312 668 0 9 2 0 1 0 0 0 1 0 0 10 61 821 2 970 0 3 31940 248 0 10 20 0 26 0 27 0 4 0 0 53 189 191 6 6 880 0 3 32080 288 3 19 49 6 26 0 15 0 9 0 0 75 415 277 6 15 790 0 3 32080 256 0 26 20 6 21 0 12 1 6 0 0 163 110 138 1 3 960 1 3 32060 256 3 45 52 28 61 0 27 5 12 0 0 195 191 223 7 11 820 0 3 32056 260 0 1 0 0 0 0 0 0 0 0 0 4 52 84 0 1 99b.用vmstat –s 显示自上次引导以来发生的系统事件$ vmstat -s0 swap ins0 swap outs0 pages swapped in0 pages swapped out392182 total address trans. faults taken 20419 page ins923 page outs30072 pages paged in9194 pages paged out65167 total reclaims65157 reclaims from free list0 micro (hat) faults392182 minor (as) faults19383 major faults85775 copy-on-write faults66637 zero fill page faults46309 pages examined by the clock daemon 6 revolutions of the clock hand15578 pages freed by the clock daemon4398 forks352 vforks4267 execs12926285 cpu context switches109029866 device interrupts499296 traps22461261 system calls778068 total name lookups (cache hits 97%)18739 user cpu34662 system cpu52051435 idle cpu25252 wait cpuc.用vmstat –S 统计交换的情况$ vmstat -Sprocs memory page disk faults cpur b w swap free si so pi po fr de sr f0 s0 s6 -- in sy csus sy id0 0 0 200968 17936 0 0 0 0 0 0 0 0 0 0 0 109 43 24 00 100d.使用sar察看CPU使用情况$ sar -uSunOS venus 5.8 Generic sun4u 09/07/9900:00:00 %usr %sys %wio %idle01:00:00 0 0 0 10002:00:02 0 0 0 10003:00:00 0 0 0 10004:00:00 0 0 0 10005:00:01 0 0 0 10006:00:00 0 0 0 10007:00:00 0 0 0 10008:00:01 0 0 0 10008:20:00 0 0 0 10008:40:00 0 0 0 10009:00:00 0 0 0 10009:20:00 0 0 0 10009:40:00 0 0 0 10010:00:00 0 0 0 10010:20:00 0 0 0 10010:40:01 0 0 0 10011:00:00 5 2 10 82Average 0 0 0 100如果%idle一直为0或较低的值,那么应该使用其他工具并对应用进行分析。
e.使用iostat察看I/O和CPU的使用情况$ iostat 5tty sd0 sd6 nfs1 nfs49 cputin tout kps tps serv kps tps serv kps tps serv kps tps serv us sy wt id0 0 1 0 49 0 0 0 0 0 0 0 0 150 0 0 1000 47 0 0 0 0 0 0 0 0 0 0 0 00 0 0 1000 16 0 0 0 0 0 0 0 0 0 0 0 00 0 0 1000 16 0 0 0 0 0 0 0 0 0 0 0 00 0 0 1000 16 44 6 132 0 0 0 0 0 0 0 0 00 0 1 990 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1000 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1000 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1000 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1000 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1000 16 3 1 23 0 0 0 0 0 0 0 0 0 0 0 1 990 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1000 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1000 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100$ iostat -xtcextended device statistics tty cpudevice r/s w/s kr/s kw/s wait actv svc_t %w %b tin tout us sy wt idfd0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 00 0 0 0 0 100sd0 0.0 0.0 0.4 0.4 0.0 0.0 49.5 0 0 sd6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 nfs1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0nfs49 0.0 0.0 0.0 0.0 0.0 0.0 15.1 0 0nfs53 0.0 0.0 0.4 0.0 0.0 0.0 24.5 0 0nfs54 0.0 0.0 0.0 0.0 0.0 0.0 6.3 0 0nfs55 0.0 0.0 0.0 0.0 0.0 0.0 4.9 0 0该命令可以检测逻辑卷和物理卷的使用情况,如果iowait太高(超过40%),则可能存在不平衡的磁盘读写、碎片太多或内存不足导致page in/page out。