贵州省风玫瑰图
- 格式:docx
- 大小:3.57 MB
- 文档页数:14
最不利风向作用下吸收塔风致动力响应宋波;殷炳帅;曹谦【摘要】Taking desulfurizing towers of 660 MW as study objects ,finite element softwares ADINA and FLUENT were used to analyze numerical wind tunnel of desulfurizing towers .The results show that NE wind direction and 180° wind direction are the most unfavorable wind directions while structure is relatively safe at 0° wind direction .As the wind speed increases ,the acceleration response trends to increase from bottom to top and stress trends to decrease .There is stress concentration around opening at the lower part of structure ,and the wind speed has little effect on the structural stresses and displacements .There are strong mutual interference between the multi‐towers ,and structure located at wind downstream has less effect on which located at wind upstream ,while structure located at wind upstream has more effect on structure located at wind dow nstream .%以某电厂660 MW吸收塔结构为研究对象,利用ADINA 及FLUENT 有限元软件对吸收塔结构开展了数值风洞分析。
风玫瑰图识图“风玫瑰”图也叫风向频率玫瑰图,它是根据某一地区多年平均统计的各个方风向和风速的百分数值,并按一定比例绘制,一般多用八个或十六个罗盘方位表示,如图一,由于该图的形状形似玫瑰花朵,故名“风玫瑰”。
玫瑰图上所表示风的吹向(即风的来向),是指从外面吹向地区中心的方向。
风玫瑰图分为风向玫瑰图(图一)和风速玫瑰图(图二)两种,一般多用风向玫瑰图。
风向玫瑰图表示风向和风向的频率。
风向频率是在一定时间内各种风向出现的次数占所有观察次数的百分比。
根据各方向风的出现频率,以相应的比例长度,按风向从外向中心吹,描在用8个或16个方位所表示的图上,然后将各相邻方向的端点用直线连接起来,绘成一个形式宛如玫瑰的闭合折线,就是风玫瑰图。
图中线段最长者,即外面到中心的距离越大,表示风频越大,其为当地主导风向,外面到中心的距离越小,表示风频越小,其为当地最小风频,如图三中甲,①>②,①为主导风向,②为最小风频;外面到中心的距离较大,为当地主导风向,如其主导方向相反,则为季风风向,如图三中乙图,其主导风向为东北——西南方向。
建筑物的位置朝向和当地主导风向有密切关系。
如把清洁的建筑物布置在主导风向的上风向;把污染建筑布置在主导风向的下风向,最小风频的上方向;污染大气的建筑布局在与季风风向垂直的郊外,以免受污染建筑散发的有害物的影响。
风玫瑰图是消防监督部门根据国家有关消防技术规范在开展建审工作时必不可少的工具,一般由当地气象部门提供。
它的作用主要表现在二个方面:一、在城市规划中,可以根据风玫瑰图正确确定大型易燃、可燃气体和液体贮罐、易燃、可燃材料堆场、大型可燃物品仓库以及散发可燃气体、液体蒸气的甲类生产厂房或甲类物品库房及生活区的位置。
由于这类贮罐、危险物品仓库、堆场火灾危害性较大,而且建造过程中的投资也比较大,一旦建好就将成为永久性的建筑物或构筑物,因此,在审核图纸时,一定要根据风玫瑰选择恰当的位置,避开城市市区和居民生活区及重要的工矿企业,防止遗留先天性的重大火险隐患。