水泵安装、使用、维护说明书Type NG slurry PumpINST ALL TION, OPERA TION, MAINTENANCEMANUAL一、水泵的安装Pump installation水泵的安装Pump installation1、水泵安装准备工作1. The preparation work for pump installation.(1)检查水泵和电机,确知在运输和装卸过程中没有损伤。
Check the pump and motor, ensure there were no damage during the transportation and load or unload.(2)检查工具和起重机械,并检查机器的基础。
Check the tools and lifting equipment and also the basement of machine. (3)检查配套提供的压力表及表座。
Check the manometer and gauge stand of affiliated equipments2、水泵安装顺序Pump installation order(1)整套泵运抵现场时,都已装好电机;校平底座时,可不必卸下水泵和电机。
The motor have been installed when a whole set of pump arrived scene. When collate the basement, no need to demount the pump and motor.(2)在水泥基础上安装水泵时,基础平面应用水平找平,待基础水泥凝固后将泵安装在基础上,并用水平仪检查水平情况,如不平,应用垫铁调正,直到水平为止,然后通过灌浆孔由混凝土浇灌底座和地脚螺栓孔眼。
When install pump on the cement base, regulate the foundation flat by the standard. Check the condition of standard by thegradienter, if not flat, regulate it by the parallels until horizontal, use concrete to irrigate basement and foundation bolt hole by the grout hole. (3)水泥干固后,检查底座和地脚螺栓是否松动,合适后拧紧地脚螺栓的螺母,最后再检查一下整台机组的水平度,稍有不平时,可用斜铁找平。
玛尔斯泵工安全操作规程模版工安操作规程模版第一章总则第一条根据《特种设备安全法》、《特种设备安全法实施细则》、《特种设备使用单位安全管理规定》等国家法律法规的规定,结合我公司特种设备使用实际,制定本工安操作规程。
第二条本规程适用于我公司特种设备(包括玛尔斯泵等)的安全管理和操作使用人员。
特种设备操作人员应严格遵守本规程。
第三条特种设备操作管理人员应按照国家法律法规和公司制度规定履职尽责,确保特种设备安全运行。
第四条特种设备操作人员应通过专业培训和资格考核,持有相关特种设备操作证书方可上岗操作。
第五条特种设备操作人员应熟悉特种设备的结构、工作原理和使用方法,严格按照操作规程操作,保证设备安全运行。
第六条特种设备操作人员在操作过程中应注意保持良好的工作状态,不得酗酒、吸烟或服用影响操作安全的药物。
第七条特种设备操作人员应自觉遵守操作纪律,不得擅自修改设备工作参数或进行未经许可的操作。
第八条特种设备操作人员应与配合其他工作人员进行有效的沟通,协作完成各项任务。
第九条特种设备操作人员应熟悉特种设备的应急救援措施,遇到突发情况时应立即采取相应的措施并报告有关部门。
第十条特种设备操作人员应逐年接受安全培训和考核,提高安全意识和操作技能。
第二章特种设备安全管理第十一条玛尔斯泵设备应配备设备管理人员,负责设备的日常维护、检查和故障排除,保证设备的正常运行。
第十二条玛尔斯泵设备在运行前应进行设备检查,确定设备各项指标是否正常,确保设备运行安全。
第十三条玛尔斯泵设备的使用人员应严格按照设备操作手册中的操作规程进行操作,不得擅自更改工作参数或进行未经许可的操作。
第十四条玛尔斯泵设备操作人员应熟悉设备的工作原理和操作方法,能够独立操作设备,并且具备一定的维修技能。
第十五条玛尔斯泵设备操作人员应定期进行设备维修保养工作,保持设备的正常运行。
第十六条玛尔斯泵设备的检修和维护应由经过培训合格的人员进行,确保设备的安全可靠。
第十七条玛尔斯泵设备的维修记录应详细完整,记录设备的检修情况,及时消除设备故障隐患。
玛尔斯泵安全操作规程范本1. 前言本安全操作规程旨在保障使用玛尔斯泵的人员的安全,在操作过程中避免事故和伤害的发生。
所有使用玛尔斯泵的人员都必须严格遵守本规程的要求并参与相应的培训。
2. 泵房准备2.1. 操作人员在进入泵房之前,必须佩戴防护设备,包括耐酸碱手套、防冲击眼镜、防滑鞋等。
2.2. 在操作前,操作人员应确保泵房内通风良好,并检查泵房是否有明火或易燃物品,必要时进行清理。
2.3. 操作人员应检查泵房中的电源和电气设备是否正常运作,确保其无损坏和漏电的情况。
3. 泵的安装和连接3.1. 在安装玛尔斯泵之前,操作人员应仔细阅读产品说明书,并确保泵的安装位置稳定并符合要求。
3.2. 操作人员应使用合适的工具和设备,正确安装玛尔斯泵的进出口连接。
连接过程中要确保连接紧固并无漏水现象。
3.3. 在连接电源之前,操作人员必须确保泵的电气接线正确、牢固。
4. 泵的开启和运行4.1. 操作人员在启动玛尔斯泵之前,应确保泵房内其他设备处于正常关闭状态,并且工作区域无人。
4.2. 启动泵之前,操作人员应检查泵的旋转部件是否润滑良好,并确保无异常声音或振动。
4.3. 操作人员在启动泵时应以低档速度进行试运行,确保泵的运行平稳无异常。
5. 泵的停止和维护5.1. 停止泵运行前,操作人员必须先关闭电源,并确保泵的电源断开,防止意外启动。
5.2. 维护人员在进行玛尔斯泵的维护和保养时,必须戴好防护手套和眼镜,防止化学物品对皮肤和眼睛的损害。
5.3. 维护人员在更换泵的零件时,应使用原厂配件,并按照产品说明进行正确的安装和调试。
6. 应急处理6.1. 在紧急情况下,如发生火灾、漏水等,操作人员必须立即关闭玛尔斯泵的电源,并报告相关负责人。
6.2. 在泵房发生泵的故障时,操作人员应及时通知维修人员,并按照其指示进行应急处理,严禁擅自进行维修。
7. 泵的检查和记录7.1. 泵的定期检查和巡视是确保其安全运行的重要环节,操作人员应遵守规定的检查周期和方式。
玛尔斯泵安全操作规程第一章总则第一条为了保证玛尔斯泵的使用安全,保护操作人员的人身安全和设备的完好性,制定本安全操作规程。
第二条本规程适用于所有使用玛尔斯泵的操作人员。
第三条操作人员必须遵守本规程的规定,严格按照操作流程进行操作,确保泵的安全运行。
第四条管理部门应当定期对操作人员进行安全培训和技术培训,提高操作人员的安全意识和专业技能。
第五条操作人员应当仔细阅读并遵守使用手册中的安全操作规程和注意事项。
第二章安全操作规程第六条操作人员在操作玛尔斯泵前,必须穿戴好安全防护设备,包括防护眼镜、手套、耳塞等。
第七条操作人员在操作玛尔斯泵前,必须熟悉泵的组成结构、工作原理和性能参数,了解各部件的功能和作用。
第八条操作人员在操作玛尔斯泵前,必须检查泵的工作状态,确保泵的运行正常,无任何故障。
第九条操作人员在操作玛尔斯泵过程中,禁止使用过大的力气,防止损坏泵的零部件。
第十条操作人员在操作玛尔斯泵过程中,禁止任意调整泵的工作参数,保持泵的工作稳定。
第十一条操作人员在操作玛尔斯泵过程中,必须定期检查泵的润滑系统和冷却系统,确保其正常运行。
第十二条操作人员在操作玛尔斯泵过程中,禁止将异物投入泵中,防止堵塞泵的管道。
第十三条操作人员在操作玛尔斯泵过程中,禁止随意拆卸泵的零部件,必须由专业人员进行维修和保养。
第十四条操作人员在操作玛尔斯泵过程中,禁止将泵用于非正常用途,防止设备损坏和事故发生。
第十五条操作人员在操作玛尔斯泵过程中,发现任何异常情况,应立即停止操作,并向管理部门报告。
第十六条操作人员在操作玛尔斯泵过程中,应遵守现场安全规定,确保现场整洁,防止意外伤害发生。
第三章应急处置措施第十七条操作人员在操作玛尔斯泵过程中,发生泵的故障或事故时,应立即按照应急预案进行处置。
第十八条操作人员在操作玛尔斯泵过程中,发生火灾、爆炸等紧急情况时,应立即切断电源,并按照应急预案进行处置。
第十九条操作人员在操作玛尔斯泵过程中,发生人身伤害时,应立即停止操作,进行急救,并及时报告管理部门。
operation manual23table of contentsIntroduction 4 Using the Operators ManualProduct Identification 5 Water Pump5 EngineSafety 6 Safety Rules6 Hazard Symbols and MeaningsWater Pump Components 11 Component ChartAssembly 12 Connect Suction Hose to Pump12 Attach Suction Hose to Strainer Basket12 Connect Discharge HoseOperation 14 What is “Head”14 Move Water Pump to Safe Location15 Prime the Water Pump16 Locate Strainer Basket Into Water SourceStarting The Water Pump 17 Starting the Water PumpStopping The Water Pump 19 Stopping the Water Pump19 Drain and Flush Water Pump4Using the Operator’s manual The operating manual is an important part of your water pump and should be read thoroughly before initial use, and referred to often to make sure adequate safety and service concerns are being addressed.Reading the owner’s manual thoroughly will help avoid any personal injury or damage to your machine. By knowing how best to operate this machine you will be better positioned to show others who may also operate the unit.This manual contains information for the complete range of BE water pumps, and is placed in order starting from the safety requirements to the operating functions of your machine. You can refer back to the manual at any time to help troubleshoot any specific operating functions, so store it with the machine at all times.Attention: Read through the complete manual prior to the initial use of your water pumpintroduction5product identificationRecord Identification NumbersWater Pump If you need to contact an Authorized Dealer or Customer Service line (1-866-850-6662) for information on servicing, always provide the product model and identification numbers.You will need to locate the model and serial number for the machine and record the information in the places provided below. Date of Purchase:Dealer Name:Dealer Phone:Product Identification NumbersModel Number:Serial Number:EngineHorse Power:6you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. NOTICE indicates a situation that could result in equipment damage.Follow safety messages to avoid or reduce the risk of injury or death.Hazard Symbols and MeaningsSave these InstructionsSafety Rules safetyThis is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol toavoid possible injury or death.7safety Running engine gives off carbon monoxide, an odorless, 8safety9safety Starter cord kickback (rapid retraction) can result in• NEVER place hands or body parts inside of running pump or hoses.10safety Excessively high operating speeds increase risk of injury and damage 11Read this operator’s manual and safety rules before operating your water pump.water pump components1. Fuel Tank Fill tank with regular unleaded fuel. Always leave room for fuel expansion.2. Priming Plug Fill pump with water here to prime pump before starting.3. Discharge Outlet Connect discharge hose here.4. Choke Lever Prepares a cold engine for starting.5. Air Cleaner Protects engine by filtering dust and debris out of intake air.6. Recoil Starter Used for starting the engine manually.7. Engine Speed Lever Used to adjust engine speed to control pump output.8. On/Off Switch Set this switch to “On” before using recoil starter. Set switch to “Off” to stop a running engine.9. Oil Drain Drain engine oil here.10. Oil Fill Check and add engine oil here.11. Suction Inlet Connect reinforced suction hose here.12. Water Drain Plug Remove to drain water from pump and flush internal components with clean water.13. Pump Chamber Be sure to fill with water before starting.14. Fuel Shutoff Valve Used to turn fuel supply on and off to engine.Item Not Shown:Strainer Basket Used to limit passage of abrasive materials into the pump.1.4.6.8.9.10.11.12.13.14.7.5.2. 3.assemblyYour water pump requires some set up and is ready for use after it has been properly serviced with the recommended oil and fuel.ewdriver.hose with an inside diameter smaller than the pump’s discharge port size.1.Slide barb cuff over hose barb. Insert rubber seal into end of barb cuff as shown earler.2.Screw hose barb assembly onto pump in clockwise rotation until hose barb assembly is tightened securely.assembly discharge port size.1.Slide barb cuff over hose barb. Insert rubber seal into 2.Screw hose barb assembly onto pump in clockwise rotation until hose barb assembly is tightened securely.14What is “Head”Head refers to the height of a column of water that can be delivered by the discharge of the pump.Suction Head is the vertical distance between the center of the pump and the surface of the liquid on the suction side of the pump. May also be referred to as “suction lift”. The atmospheric pressure of 14.7 psi at sea level limits suction head lift to less than approximately 26 feet for any pump.Discharge Head is the vertical distance between the pump’s discharge port and the point of discharge, which is the liquid surface if the hose is submerged or pumping into the bottom of a tank.Total Head is the sum of the suction head value plus the discharge head value.As water pumping height increases, pump output decreases. The length, type, and size of the suction and discharge hoses can also significantly affect pump output. It is important for the suction operation to be the shorter part of the total pumping action. This will decrease the priming time and improve pump performance by increasing the discharge head.Suction head is a maximum of 25 feet and discharge head should be a maximum of 81 feet. Total head can not be more than 106 feet as shown on next page.Move Water Pump to Safe Operating Location For best pump performance, locate the pump on a flat, level surface as close as possible to the water to be pumped. Secure water pump to avoid tipover. Use hoses that are no longer than necessary.IMPORTANT: Direct open end of discharge hose away from home, electrical devices or anything not desired to get wet.operation15Prime the Water Pump 1. Remove priming plug from top of pump.2. Fill pump with clean, clear water up to top of discharge outlet.3. Replace priming plug.operation16Locate Strainer Basket Into Water Source Place strainer basket into water to be pumped. Basket must be fully immersed.operation17Starting the Water Pump Use the following start instructions:1. Make sure unit is on a flat, level surface and pump chamber is primed.2. Turn fuel valve (1) to “On” position. The fuel valve handle will be starting the water pump18IMPORTANT: If excessive fuel is present in the air/fuel mixture causing a “flooded” condition, move choke lever to “Run” position and pull handle repeatedly until engine starts.7. Move choke lever to “Run” position a short distance at a time over several seconds in warm weather or minutes in cold weather. Let engine run smoothly before each change. Operate with choke in “Run” position.IMPORTANT: It may take a few minutes for water pump to begin pumping water.Pump output is controlled by adjusting engine speed. Moving the engine speed lever in the “Fast” direction will increase pump output, and moving the engine speed lever in the “Slow” direction will decrease pump output.starting the water pump19stopping the water pumpStopping the Water Pump 1. Move engine speed lever to “Slow” position.2. Push on/off switch to “Off” position.3. Turn fuel valve to “Off” position.Drain and Flush Water Pump 1. Disconnect and drain suction and discharge hoses.2. Remove drain plug at bottom of pump.3. Remove primer plug from top of pump and flush internal components of pump with clean water.If you need assistance with the assembly or operation of this Water Pump please call 1-866-850-6662。
微量泵竖泵的操作流程及注意事项1.打开微量泵的电源开关。
Turn on the power switch of the micro pump.2.确保微量泵处于停止状态。
Make sure the micro pump is in the stopped state.3.察看微量泵的液体储存容器是否已安装并装满液体。
Check if the liquid storage container of the micro pump is installed and filled with liquid.4.按下启动按钮,启动微量泵。
Press the start button to start the micro pump.5.调节微量泵的流量大小和速度。
Adjust the flow rate and speed of the micro pump.6.监视微量泵的运行状态,确保其正常工作。
Monitor the operation of the micro pump to ensure it is working properly.7.当需要停止时,按下停止按钮。
Press the stop button when it is necessary to stop.8.关闭微量泵的电源开关。
Turn off the power switch of the micro pump.9.保持微量泵的清洁,定期清洗泵头和管路。
Keep the micro pump clean and clean the pump head and pipes regularly.10.注意不要让微量泵运行过载,避免损坏设备。
Be careful not to overload the micro pump to avoid damaging the equipment.11.定期检查微量泵的零部件,及时更换损坏的部分。
Regularly check the components of the micro pump and replace damaged parts in time.12.在操作微量泵时,注意安全防护,避免触电或者溢液事故。
泵类操作说明离心泵和自吸泵1、使用与保养(1)新泵使用前,应先拨动电机后面风叶或(联轴器),检查转动是否均匀、灵活、无异声。
(2)新泵首次使用,应先点动检查电机转向,正确的转向为从电机风叶看为顺时针旋转。
(3)开机前,应全部打开进口阀,使泵体及进口管路内充满液体。
(4)用出口调节阀调节泵的流量和扬程,使泵在设计的工况下运行,以获得最大节能效果,进口阀必须全部打开。
(5)在运行中应检查泵进出口压力是否符合泵的性能范围,电机功率有无超载,机封是否泄漏,电机的温升是否超标等。
2、注意事项(1)泵严禁缺液空转,必须充满液体后启动,以免损坏机封。
(2)泵严禁反转。
(3)泵严禁通过调节进口阀来调整使用性能参数,以免产生汽蚀而造成损坏。
(4)停机前,应先关闭出口调节阀,后断电源停机。
(5)如发现泵有殿堂声音、电机温长过高,电流过大等特殊情况,应立即停机检查。
齿轮泵1、泵工作时的维护(1)泵的压力及真空表的读数应符合该泵所规定的技术规范。
(2)当泵在动转中出现不正常的噪音或温升进高时,应立即停止泵的工作,进行拆检。
(3)一般情况下,不得调整安全阀,如需调整时,要用仪器校正。
2、泵工作的停止(1)切断电源;(2)关闭进出管道的阀门。
水环真空泵1、起动和停车起动:起动前,特别是长期停车的泵必须用手转动联轴器数转,确认转子能自由转动才行。
起动前应将泵体内的水全部放掉,方可起动。
起动顺序:a、关闭进气管路上的闸阀;b、打开供水管路上的闸阀,供水量逐渐增加,至供水量符合规定要求为止;c、开动电动机(此时应注意电机的正反转,在向泵体供水后应立即开动电机);d、当泵达到极限真空时,打开进气管路上的闸阀,泵开始正常工作;e、调整填料压盖,使水成滴往外滴为好,真空泵在极限真空下工作时,由于泵内产生物理作用而发生爆炸声,但功率消耗并不增大,如发现随着功率增加而产生的爆炸声,说明泵已发生故障,此时应立即停车检查。
停车:停车顺序:a、关闭进气管路上的闸阀;b、关闭供水管路上的闸阀,停水后,不应立即停泵,应使泵继续运转1-2分钟,排出部分工作液;c、关闭电动机。