西门子安全继电器3TK2807
- 格式:pdf
- 大小:340.39 KB
- 文档页数:5
西门子选型手册1 6ES7 212-1AB23-0XB0 CPU(8I/6O)晶体管输出2 6ES7 212-1BB23-0XB0 CPU (8I/6O)继电器输出3 6ES7 212-1AB23-0XB8 CPU(8I/6O)晶体管输出 CN4 6ES7 212-1BB23-0XB8 CPU (8I/6O)继电器输出 CN5 6ES7 214-1AD23-0XB0 CPU(14I/10O)晶体管输出6 6ES7 214-1AD23-0XB8 CPU(14I/10O)晶体管输出 CN7 6ES7 214-1BD23-0XB0 CPU(14I/10O)继电器输出8 6ES7 214-1BD23-0XB8 CPU(14I/10O)继电器输出 CN9 6ES7 214-2AD23-0XB0 CPU224XP(14DI/10DO,2AI,1AO)晶体管输出10 6ES7 214-2BD23-0XB0 CPU224XP (14DI/10DO,2AI,1AO)继电器输出11 6ES7 214-2AD23-0XB8 CPU224XP (14DI/10DO,2AI,1AO)晶体管输出12 6ES7 214-2BD23-0XB8 CPU224XP (14DI/10DO,2AI,1AO)继电器输出13 6ES7 216-2AD23-0XB0 CPU ( 24I/16O ) 晶体管输出14 6ES7 216-2BD23-0XB0 CPU(24I/16O)继电器输出15 6ES7 216-2AD23-0XB8 CPU ( 24I/16O ) 晶体管输出 CN16 6ES7 216-2BD23-0XB8 CPU(24I/16O)继电器输出 CN17 6ES7 221-1BF22-0XA0 8点24VDC输入18 6ES7 221-1BF22-0XA8 8点24VDC输入 CN19 6ES7 221-1BH22-0XA0 16点24VDC输入20 6ES7 221-1BH22-0XA8 16点24VDC输入 CN21 6ES7 222-1HF22-0XA0 8点继电器输出22 6ES7 222-1HF22-0XA8 8点继电器输出 CN23 6ES7 222-1BF22-0XA0 8点24VDC输出24 6ES7 222-1BF22-0XA8 8点24VDC输出 CN25 6ES7 223-1PH22-0XA0 8入8出模块继电器输出26 6ES7 223-1PH22-0XA8 8入8出模块继电器输出 CN27 6ES7 223-1PL22-0XA0 16入16出模块继电器输出28 6ES7 223-1PL22-0XA8 16入16出模块继电器输出 CN29 6ES7 223-1HF22-0XA0 4入4出模块继电器输出30 6ES7 223-1HF22-0XA8 4入4出模块继电器输出 CN31 6ES7 223-1BF22-0XA0 4入4出24VDC32 6ES7 223-1BF22-0XA8 4入4出24VDC CN33 6ES7 223-1BH22-0XA0 8入8出24VDC34 6ES7 223-1BH22-0XA8 8入8出24VDC CN35 6ES7 223-1BL22-0XA0 16入16出24VDC36 6ES7 223-1BL22-0XA8 16入16出24VDC CN37 6ES7 231-0HC22-0XA0 4入模拟量模块38 6ES7 231-0HC22-0XA8 4入模拟量模块 CN39 6ES7 235-0KD22-0XA0 4入1出模拟量模块40 6ES7 235-0KD22-0XA8 4入1出模拟量模块 CN41 6ES7 232-0HB22-0XA0 2出模拟量模块42 6ES7 232-0HB22-0XA8 2出模拟量模块 CN43 6ES7 277-0AA22-0XA0 PROFIBUS-DP模块44 6ES7 272-0AA30-0YA0 TD 200显示设定单元45 6ES7 901-3CB30-0XA0 计算机编程电缆及软件46 6ES7 291-8GF23-0XA0 EEPROM 64K47 6ES7 291-8BA20-0XA0 电池48 6ES7 290-6AA20-0XA0 扩展转接电缆 0.8米49 6ES7 231-7PD22-0XA0 4路热电耦模块50 6ES7 231-7PD22-0XA8 4路热电耦模块 CN51 6ES7 231-7PB22-0XA0 2路热电阻模块52 6ES7 231-7PB22-0XA8 2路热电阻模块 CN53 6GK7243-1EX00-0XE0 以太网通讯卡西门子可编程SIEMENS S7-300系列序号型号描述1 6ES7 312-1AE13-0AB0 CPU312,16KRAM, MAX 256DI/O,64AI/O,MMC2 6ES7 312-5BE03-0AB0 CPU312C,32KRAM, 本机10I/6O,256DI/O,64AI/O,40PIN3 6ES7 313-5BF03-0AB0CPU313C,64KRAM,MAX 1016DI/O,253AI/O,2个40PIN<, /P>4 6ES7 313-6CF03-0AB0 CPU313C-2DP,64KRAM,MAX 8192DI/O,512AI/O,40PIN5 6ES7 314-1AG13-0AB0 CPU314,48KRAM,MAX1024DI/O,256AI/O,MMC6 6ES7 314-6BG03-0AB0 CPU314, 96KRAM,MAX1024DI/O,256AI/O,MMC9 6ES7 314-6CG03-0AB06ES7 315-2AG10-0AB06ES7 307-1BA00-0AA0CPU314C-2DP,96KRAM,MAX8192DI/O,512AI/O,2个40PINCPU315-2DP,128KRAM,MAX16384DI/O,1024AI/O,MMCS7-300电源DC24V,2A10 6ES7 307-1EA00-0AA0 S7-300电源DC24V,5A11 6ES7 307-1KA01-0AA0 S7-300电源DC24V,10A12 6ES7 321-1BL00-0AA0 数字输入模块32点入,DC24V13 6ES7 321-1BH02-0AA0 数字输入模块16点入,DC24V14 6ES7 321-1FF01-0AA0 8点120V/230V AC 输入15 6ES7 322-1BL00-0AA0 数字输出模块32点出,DC24V,0.5A16 6ES7 322-1HF01-0AA0 数字输出模块8点继电器出,AC220V,2A17 6ES7 322-1BH01-0AA0 数字输出模块16点出,DC24V,0.5A18 6ES7 322-1HH01-0AA0 数字输出模块16点继电器输出2A19 6ES7 322-1FH00-0AA0 数字输出模块16点输出0.5A20 6ES7 323-1BH01-0AA0 数字输入/输出模块,8入/8出,DC24V,0.5A21 6ES7 323-1BL00-0AA0 数字输入/输出模块,16入/16出,DC24V,0.5A22 6ES7 331-7KF02-0AB0 模拟量输入模板,8通道,0~10V,4~20MA23 6ES7 331-7KB02-0AB0 模拟量输入模板,2通道24 6ES7 332-5HD01-0AB0 模拟量输出模板,4通道,0~10V,4~20mA25 6ES7 332-5HB01-0AB0 模拟量输出模板,2通道26 6ES7 340-1AH02-0AE0 点对点通讯模板,CP340-1A,带RS232C口27 6ES7 340-1AH01-7BA0 CP340软件手册28 6ES7 340-1CH02-0AE0 点对点通讯模板,CP340-1C,带RS485口29 6ES7 350-1AH03-0AE0 单通道计数模块(FM350-1)30 6ES7 350-1AH00-7BG0 FM350-1组态软件手册31 6ES7 350-2AH00-0AE0 8通道计数模块(FM350-2)37 6ES7953-8LF20-0AA06ES7953-8LG11-0AA06ES7953-8LJ20-0AA06ES7953-8LL20-0AA06ES7953-8LM20-0AA06ES7 971-1AA00-0AA0 MMC 64KMMC 128KMMC 512KMMC 2MMMC 4M后备电池,3.4V,1Ah(CPU313,314用)38 6ES7 392-1AJ00-0AA0 前连接器,20针39 6ES7 392-1AM00-0AA0 前连接器,40针40 6ES7 390-1AE80-0AA0 导轨,480mm41 6ES7 390-1AF30-0AA0 导轨,530mm42 6ES7 390-1AJ30-0AA0 导轨,830mm43 6ES7 360-3AA01-0AA0 中央模板接口模板44 6ES7 361-3CA01-0AA0 扩展模板接口模板45 6ES7 365-0BA01-0AA0 接口模板(一对),带1M电缆46 6ES7 368-3BB01-0AA0 接口模板连接电缆,1M47 6ES7 368-3BC51-0AA0 接口模板连接电缆,2.5M48 6ES7 972-0CB20-0XA0 PC MPI电缆49 6ES7 972-0BA41-0XA0 L2网接口不带编程口50 6ES7 972-0BB41-0XA0 L2网接口带编程口51 6ES7 972-0AA01-0XA0 RC485 L2/MPI中继器52 6GK1 561-1AA01 CP5611 PCI通讯卡53 6GK1 561-3AA01 CP5613 PCI通讯卡54 6GK7 342-5DA02-0XE0 CP342-5通讯模块55 6A V6642-0DA01-1AX0 OP177B 5.7寸用户内存2048K 分辨率320×240 25656 6A V6642-0DC01-1AX0 OP177B 5.7寸用户内存2048K 分辨率320×240 蓝色57 6A V6 642-0AA01-0AX0 TP177A 触摸屏 5.7寸分辨率320×240 蓝色替代TP170A58 6A V6 642-0BA01-1AX0 TP177B 触摸屏 256色替代TP170B59 6A V6 641-0DD01-1AX0MP277 替代TP270-10 10.4寸用户内存6M 分辨率640×480 按键60 6ES7 354-1AH01-0AE0 FM354 伺服电机定位模块61 6ES7 355-0VH10-0AE0 带4个模拟输出的四通道闭环控制模块 FM355C62 6ES7 355-1VH10-0AE0 用于4个步进或脉冲控制器的闭环控制模块FM355S西门子可编程SIEMENS S7-400系列序号型号描述1 6ES7400-1TA01-0AA0 底板2 6ES7400-1JA01-0AA0 底板3 6ES7412-2XJ05-0AA0 CPU4124 6ES7414-2XK05-0AB0 CPU4145 6ES7407-0KA01-0AA0 10A电源6 6ES7952-1KK00-0AA0 1M存储器7 6ES7952-1KL00-0AA0 2M存储器8 6ES7971-0BA00 后备电池9 6ES7421-1BL01-0AA0 32点数字输入,24VDC10 6ES7421-7BH01-0AB0 16点数字输出,24VDC11 6ES7422-1BL00-0AA0 32点数字输出,24VDC12 6ES7422-1BH11-0AA0 16点数字输出,24VDC13 6ES7422-1HH00-0AA0 16点继电器输出14 6ES7431-7QH00-0AB0 16点模拟量输入15 6ES7431-1KF00-0AB0 8点模拟量输入16 6ES7431-7KF00-0AB0 8点模拟量输入17 6ES7431-7KF10-0AB0 8点模拟量输出18 6ES7432-1HF00-0AB0 8点模拟量输出19 6ES7460-0AA01-0AB0 扩展模块20 6ES7461-0AA01-0AA0 扩展模块21 6ES7461-0AA00-7AA0 终端电阻22 6ES7468-1BB50-0AA0 扩展电缆23 6ES7492-1AL00-0AA0 接线端子。
交流接触器3TF30,3TF31Q/SMS 003,GB14048.4,DIN VDE0660,IEC 60947-4-1XK06-201 0025 使用说明书编号: 4NEB 502 0815-10 d5中 文A001253注 意危险电压会引起触电和燃烧。
调整、维修前请先切断电源。
防止触及限定保护的带电部分保护等级 IP 20 按 IEC 60529! 触指安全性符合 DIN VDE 0106 第100部分。
调整、维修应由专业人员才能担任,并严格按照使用说明书。
安装外形尺寸见图Ⅰ(单位:mm ) 图Ⅰa 交流操作 图Ⅰb 直流操作接触器可借助接触器底上滑鞍扣装在35mm 宽的标准安装导轨(DIN EN 50 022)上。
或用2只M4螺钉安装,用螺钉安装时,一定要装平垫圈和弹簧垫圈。
在安装时要防止外来颗粒,例如防止细铁屑进入里面。
如果接触器暴露于灰砂、粉尘及腐蚀性环境中,应加装防护罩。
允许的安装位置见图Ⅱ。
图Ⅱ a 交流操作 图Ⅱ b 直流操作接线紧固螺钉可用电动螺丝刀旋紧。
螺丝刀刀口宽度:5~6mm允许的接触器导线截面积(主、辅触头) 实心导线 2×0.5~1 mm 2 2×1~2.5 mm 21×4 mm 2具有套筒端的多股导线 2×0.75~2.5 mm 2 AWG 制导线 2×AWG18~12 紧固力矩 0.8~1.4Nm/7~12lb.in 辅助触头组紧固力矩 0.8~1.1Nm/7~10lb.in 仅采用75℃铜线接线端子的电路图及位置见图Ⅲ。
图Ⅲ a 1NO 图Ⅲ b 1NC图Ⅲ c 无辅助触头组操作遵守控制电压(见线圈标牌)接触器通断状态由接触器支架显示:见图Ⅳ。
当系统电压施加且负载连接时,不要靠压下接触器支架来操作接触器。
维修保养下列零件可以更换:线圈、单极辅助触头组 3TX40。
订货号见产品样本。
只有用本来的备用件才能保证接触器的安全可靠。
20…40 mm行程∙SBX31、SBV31工作电压 AC 230 V,三位控制信号∙SBX81、SBV81工作电压 AC 24 V,三位控制信号∙SBX61、SBV61工作电压 AC 24 V, DC 0…10 V控制信号∙SBX61、SBV61可选4…20 mA控制信号功能,由AZX420功能模块来实现,断信号时执行器回到全关位∙SBX151.00、SBV151.00工作电压AC 24 V,4…20 mA控制信号,断信号时保持阀位∙直接安装在阀门上,无需调节∙手动调节扳手和阀杆行程指示用于西门子二通阀 VVF47..、VVI47和三通阀VXF47.. VXI47..系列型号的阀门执行器,驱动行程为 20 mm和 40 mm,在暖通空调系统中作为控制阀使用。
产品型号物料编号定位信号行程驱动力工作电压 [V]运行时间[s]手动操作SBX61S55160-A100DC 0…10 V20 mm 700 N AC 24 V120手动调节扳手SBX81S55160-A101三位SBX31S55160-A102AC 230 V SBX151.00S55160-A1084…20 mA AC 24 VSBV61S55160-A103DC 0…10 V40 mm 1600 N AC 24 V180手动调节扳手SBV81S55160-A104三位SBV31S55160-A105AC 230 VSBV151.00S55160-A1094…20 mA AC 24 V 附件产品型号物料编号说明SBX31SBV31SBX81SBV81SBX61SBV61SBX151.00SBV151.00AZX420 S55845-Z120功能模块--最多1个-示例产品型号订货号说明数量SBX61S55160-A100执行器1AZX420S55845-Z120功能模块1交付执行器、阀门和附件分开包装和供货。
2二通阀关于执行器的详细信息,请参阅“电动执行器 SBX..、SBV..”的用户手册,该文档的编号是CB1P4519en。
页 次1 of 6通报主题: 3TK2828安全继电器技术知识通报内容:一、概述紧急停止模块实质为安全继电器,是紧急停止电路的核心部分,其内部由数个继电器与电路组合而成 ,具有低失误率、低失效率的特点。
连铸常用的急停模块是西门子的3TK2828以及3TK2824,两者都是24V DC 供电,且都为双通道,其中3TK2828有断电延时触点,以下以3TK2828为例进行简单介绍。
二、功能描述及面板结构图页次 2 of 61.工作时Y10、Y11、Y12串联构成回路1,Y21、Y22串联构成回路2,两回路都与急停按钮串联,Y33、Y34短接激活急停模块,短接后会自保持。
(K1 、K2)2.急停模块主要通过接触器或继电器的触点和设备电气回路或PLC的DI、DO模块串联,以实现设备的停止和互锁。
急停产生时,急停模块切断动力电路中的主动力开关(主要是接触器)电路,使主电源断开实现停止,同时将急停信息反馈给PLC。
设备急停页次 3 of 6单元之间的互锁信息可以在HMI上的”Emergency Stops”上查看。
三、紧急停止模块复位方法说明:Y10、Y11与Y12组成通道1,Y21与Y22组成通道2,通道1对应急停模块的K1,通道2对应急停模块的K2。
Y33与Y34时通过接触器常闭触点自动复位。
)在保证通道1和通道2都是通路的情况下(如果不通则需短接),按以下方法复位:1.当紧急停止模块只有一个通道回路正常,另一个通道不通时,需将两个通道短接(即将Y11与Y21短接),触发导通后即可。
(模块导通后会自保持,不必一直短接)2.当紧急停止模块两个通道都不通时,需将Y33与Y34短接,触发导通后即可。
(模块导通后会自保持,不必一直短接)四、炼钢厂紧急停止设计概述(1) MCC紧急停止设计MCC即马达控制中心,由电气室集中控制现场马达,现场可实现紧急停止。
下面以MCC类型二分析马达的启动和紧急停止的实现。
页 次4 of 6马达M 运转启动过程:MCB 主断路器闭合 → 引自MCB 下游的Y01得电(有些Y01控制电取自其它)→ K4,K6线圈得电→K4,K6常开触点闭合,ready 状太灯亮,K2动作,满足马达启动条件→当Y10的启动信号输入时(来自按钮,PLC 或HMI )→K31动作→K21线圈得电→K1主接触器闭合→电机运行,此时线路(K6K4紧停开关K31K21K2)必须全通状态。
Operation permissible in switchgear cabinet with degree of protection IP 54 only!You can use the safety combinations 3TK2827/28 in EMERGENCY STOP devices as per EN 418, in safety circuits as per VDE 0113 Part 1 (06.93) and/orEN 60 204-1 (12.97), such as for monitoring safety guards, or in circuits with controlled standstill requirement (STOP Category 1).Depending on the external circuitry, you can use this device to install Safety Category 4 instantaneous release circuits and Safety Category 3 delayed release circuits according to DIN EN 954-1.The 3TK2827/28 safety combinations possesses two delayed and two instanta-neous release circuits as NO circuits and one instantaneous signal circuit as NC circuit. Five LEDs indicate the operating status and the functions.The redundant safety relays, the electronics and the operated motor contactors are tested for proper functioning when the EMERGENCY STOP button or the limit switch button is unlatched, and when ON circuit Y33, Y34 is closed.On the 3TK2827 (monitored start), the ON circuit Y33, 34 is checked for short-cir-cuit. This means that a fault ist detected when Y33, 34 is closed before the EMERGENCY STOP button is closed.WARNING:HAZARDOUS VOLTAGECAN CAUSE ELECTRICAL SHOCKAND BURNS.DISCONNECT POWER BEFORE PROCEEDING WITH ANY WORK ON THIS EQUIPMENT.ApplicationFunctions and connectionsTerminal assignmentsOperating voltage A1A2L/+N/-Output13, 1423, 2431, 32Release circuit 1, instantaneous Release circuit 2, instantaneous Signal circuit, instantaneous 47, 4857, 58Release circuit 1, delayed (t)Release circuit 2, delayed (t)Function 3TK28273TK2827 / 3TK28283TK28281-channelON pushbutton at Y33, 34Jumper from Y11 to Y12Jumper from Y21 to Y22EMERGENCY STOP circuits at Y10, Y11Feedback circuit or Jumper to Y33, Y34.Important:Y21, 22 must close before or at the same time as Y11, 122-channelJumper from Y10 to Y11EMERGENCY STOP circuits at Y11, 12 and Y21, 22Cable lengthsfor 2 x 1.5 mm 2150 nF/km max. 1000 m (total cable length for sensors and power supply lines)FiguresFig. I: Dimension drawings (dimensions in mm)Fig. II:Installation / Cage ClampFig. III:Internal circuit: ¿ power pack, À PTC fuse,Á control logic, Â Channel 1, Ã Channel 2Ä Channel 1 (t), Å Channel 2 (t)3TK2827, Monitored start for EMERGENCY STOP Fig. IV: Safety category 2Fig. V: Safety category 33TK2828, Autostart for Guard door monitoring Fig. VI: Safety category 2Fig. VII: Safety category 3Be sure to fit the specified fuses. Otherwise safe interruption in the event of a fault cannot be guaranteed.For further data and accessories see Catalog NS K.OperationLEDs Operation POWERCh1Ch2Ch1(t)Ch2(t)PS EMERGENCY STOP ON Release circuits ONnot activatedactivatedclosed activated, delay time elapsed not activated open not activatednotactivatedopenactivated, delay time elapsed not activated FK 1 & 2 open, FK 1 (t) & FK2 (t) closedFaults •Relay fusion-welded•Motor contactor fusion-welded •Defect in electronics •Short-circuit in ON circuitopenCross or ground faults in EMER-GENCY STOP circuit (min. fault current I Kmin = 0.5 A; PTC fuse trips)Faultclearance1.Switch supply voltage off.2.Clear fault or replace device.3.Switch supply voltage back on.Technical dataPermissible ambient temperature T u Operation/storage-25 to +60°C/-40 to +80°C Degree of protection to EN 60 529IP 20Rated insulation voltage U i300 V Rated impulse withstand voltage U imp 4 kVRated control supply voltage U s 24 V DC, 24 V AC, 115 V AC, 230 V AC Rated power5 W/5 VAAC/DC operating range0.85 to 1.1 x U s Shock resistance (half-sine) as per IEC 600688 g /10 ms Weight0.580 kg Recovery time after EMERGENCY STOP min. 200 msRelease time after EMERGENCY STOP 0.05 to 3 s or 0.5 to 30 s adjustable Response time max. 80 msUtilization categoryas per DIN VDE 0660 Part 200, IEC 60947-5-1Rated operational voltage U e(V)Rated operational current I eon loading of instantaneous / delayed release circuits (A)60 °C 70 °C AC-152305/34/3DC-1324 5/24/2115 0.2/0.20.2/0.22300.1/0.10.1/0.1Continuous current I th5/54/4Short-circuit protection Signal circuit and release circuit Fuse links Duty class DIAZED gL(gG) 6 A / quick response 10 A Control supply voltage gL(gG) 2 AThe safety combination is protected by an internal self-healing PTC fuse (multifuse).2Safety Combination3TK2827, 3TK2828DIN EN 60 439 Part 1, VDE 0660 Part 500 (04.94)InstructionsOrder No.: 3ZX1012-0TK28-5CA1Technische Änderungen vorbehalten. Subject to change without prior notice © Siemens AG 1998Bestell-Nr./Order No.: 3ZX1012-0TK28-5CA1 Printed in the Federal Republic of GermanyTechnical Support:Tel: ++49 (0) 9131-7-43833 (8°° - 17°° MEZ)Fax: ++49 (0) 9131-7-42899E-mail: NST.technical-support@erl7.siemens.de Internet: www.ad.siemens.de/support。
2/23RT20 1S003RT20 2S02/3IEC 60947-5-1,EN 60947-5-1(辅助触点)3RT2 接触器经过气候测试,适用于全球任何气候条件。
设备应用的环境与标准的工业环境(EN 60721-3-3 所规定)不同时,需要考虑环境对产品可靠性和使用寿命的影响,并采取相应的防护措施。
如有必要请联系西门子技术支持。
3RT2 接触器具有 EN 50274 中规定的“指触防护”功能。
1 个辅助触点(1NO 或 1NC )。
2 个辅助触点(1NO + 1NC )。
110 V 或者电流不超过 100 mA 的情况下进行切 3RH2 中间继电器具有极高17 V 电压下最小接通电 DC 或者交流 AC 操作的型号。
3RT2 接触器可以提供阻容吸收(RC )、压敏电阻、抑制二极管以及二极管组合(齐纳二极管与二极管组合)四类浪涌抑制器,用于抑制线圈浪涌。
注意:使用浪涌抑制器抑制线圈过电压,会造成接触器常开触点 NO 分断延时以及常闭触点 NC 接通延时(抑制二极管将增加延时 6 到 10 倍,二极管组合将增加延时 2 到 6 倍,压敏电阻将增加延时 2 到 5 ms )。
注意:此处订货号含义解释仅供参考,详见“选型和订货信息”。
2/43 交流操作其它线圈规格参见 2/7 页。
1 )常见使用类别的含义:接触器交流AC-1:无感或微感负载、电阻炉AC-2:绕线式感应电动机的起动、分断AC-3:鼠笼型感应电动机的起动、运转中分断AC-4:鼠笼型感应电动机的起动、反接制动或反向运转、点动直流DC-1:无感或微感负载、电阻炉DC-3:并励电动机的起动、反接制动或反向运转、点动、电动机在动态中分断DC-5:串励电动机的起动、反接制动或反向运转、点动、电动机在动态中分断辅助触点和中间继电器交流AC-11:控制交流电磁铁负载AC-12:控制电阻性负载和光电耦合隔离的固态负载AC-14:控制小型电磁铁负载(≤ 72 VA )AC-15:控制电磁铁负载(> 72 VA )直流DC-12:控制电阻性负载和光电耦合隔离的固态负载DC-13:控制电磁铁负载3RT20 1.-1A. . .3RT20 1.-2A. . .3交流操作3RT20 2.-1A..03RT20 2.-2A..0其他线圈规格参见 2/7 页。
西门子安全继电器的运行规定什么是安全继电器安全继电器是一种用于控制和保护机械设备和生产线的装置,它能够通过多种方式监测机器运行状态并控制机器的关闭或切换。
西门子安全继电器是一款应用广泛的安全继电器,在机器自身保护和人员安全保护方面发挥了重要作用。
运行规定及注意事项1、安全继电器的安装安装安全继电器应遵守国家有关技术标准。
应根据机床的特点、机床的主体结构、执行器和安全继电器本身的特点以及要保护的机器的运行状态选择合适的安装位置和安装方式。
2、正确接线正确接线是安全继电器能否正常运作的重要保证。
安全继电器的接线应符合设备的电气图纸或接线图纸,检查接线时应断电操作,并保证接线稳固可靠,避免接触不良和运行时断电。
3、保持安全继电器的状态安全继电器应控制机床或生产线的损坏或危害人身安全的运动部件。
在使用过程中要保持它的状态稳定、可靠,保证在机器出现异常情况时能够快速切断电源,避免损失扩大、威胁到人身安全。
4、修理保养安全继电器应定期进行检修和保养。
检修和保养时应在设备断电的情况下进行,检查安全继电器的外观是否有损坏和腐蚀,是否有松动和损坏的电线;清理安全继电器,要保证安全继电器的密闭性;检查安全继电器触点,在安全继电器没有断电的情况下,手动旋转安全继电器的“旋把”观察触点是否吸合,如不吸合,应检查触点间距和通路间距。
注意事项1.安全继电器在机器的使用过程中发挥了重要的作用,未经训练的人员不得擅自拆卸、更改和不当使用安全继电器,以免造成人员伤亡和机器损坏。
2.安全继电器应从合法正规途径购买,避免使用伪劣假冒产品,以免出现因供应来源不明、产品质量不佳造成的不良后果。
3.安全继电器在运行过程中应严格执行操作规程,保证电器产品的稳定运行,避免出现意外事故的发生。
结语安全继电器是现代工业生产中不可或缺的电器装置,它发挥着保护人员和设备、防止意外事故的重要作用。
在使用过程中,要严格遵守相关规定和要求,加强安全意识,提高使用技能,确保安全继电器的稳定运行,保护生产和人员安全。
Betrieb nur im Einbauraum mit IP 54 zulässig (z. B. Schaltschrank)!-NOT-AUS-Schaltungen-Schaltungen zur Überwachung von Schutzeinrichtungen (z.B. Schutz-gittern)-Schaltungen, bei denen gesteuertes Stillsetzen gemäß DIN EN 60204-1, VDE 0113 Teil 1: (1998-11) STOP-Kategorie 1 erforderlich ist.Bei Geräten, deren Netzspannung gleich der Steuerspannung ist, ist unbedingt die DIN EN 60204-1, VDE 0113 Teil 1: (1998-11), Punkt 9.1.1 zu beachten!Die interne Steuerung der Schützsicherheitskombination ist nach DIN EN 60204-1, VDE 0113 Teil 1: (1998-11), Absatz 9.4.2.2 ausgeführt, so dass im Falle eines Fehlers in einem Hilfsschütz die Funktion des Sicherheitsstrom-kreises erhalten bleibt. Die Versorgungsspannung muss den Anforderungen der DIN EN 60204-1, VDE 0113 Teil 1: (1998-11) entsprechen (der Anschluss “A2“ muss an die mit dem Schutzleitersystem verbundene Seite des Steuerstromkreises angeschlossen werden). Bei jedem EIN- und AUS-Zyklus der zu schaltenden Maschine werden die Schaltglieder der Hilfs-schütze auf korrektes Öffnen und Schließen überprüft. Dies geschieht z.B. durch:-Ab- und Zuschalten der Steuerspannung durch den Hauptschalter -Betätigen und Entriegeln der NOT-AUS-Einrichtung -Öffnen und Schließen des Schutzgitters.Geräteschaltpläne und Anschlussbeispiele , siehe Bild III :a Innenschaltbild (DC-Ansteuerung), Prinzipdarstellung b Schutztür-Schaltung (2kanalig)c NOT-AUS-Schaltung (2kanalig)d Schutztür-Schaltung (2kanalig)Automatischer Anlauf mit zwangsöffnenden Schaltern.e NOT-AUS-Schaltung (2kanalig mit einem Zusatzbaustein 3TK29...).Hinweis: Eine 1kanalige Ansteuerung der Schützsicherheitskombination ist realisierbar, indem man die Schutzeinrichtung zwischen den Anschluss X1 und den verbundenen Anschlüssen X3; X5 schaltet.Die außenliegende Ansteuerung ist beispielhaft, sie muss durch eine Risi-kobewertung durch den Anwender festgelegt werden.Weitere Applikationen auf Anfrage.Maßbilder (Maße in mm), siehe Bild I .Seitlicher Mindestabstand zu geerdeten Teilen: 3 mm (siehe Bild IIa ).Anschluss, siehe Bild IIb .Plombierabdeckung, siehe Bild IIc .Bei der Montage Schützsicherheitskombination abdecken, wenn Fremdkörper (z.B. Bohrspäne) auf die Geräte gelangen können. Bei Verschmutzungsgefahr, starkem Staubanfall oder aggressiver Atmo-sphäre Schützsicherheitskombination in Gehäuse einbauen.Reinigung: Staubablagerungen entfernen (absaugen!).Die Betriebszustände des Gerätes:“NETZ“ zeigt an, dass das Gerät an Spannung liegt.“KANAL 1“ und “KANAL 2“ leuchten, wenn der EIN-Taster betätigt wurde und die NOT-AUS- bzw. Schutztüreinrichtung geschlossen ist.Warnung:Gefährliche elektrische Spannung!Kann zu elektrischem Schlag und Verbrennungen führen.Vor Beginn der Arbeiten Anlage und Gerät spannungsfrei schalten.AnwendungsbereicheFunktionsbeschreibung und AnschlusshinweiseMontageBetriebBeim Einlegen der Drahtbrücken sind die EGB-Richtlinien zu beachten. Erdungsmanschetten anlegen!Kurzschlußschutz für Freigabekreis und Meldekreis:Schweißfreie Absicherung bei -Sicherungseinsätze Absicherung der Sicherheitskombination:-G-Sicherung -Sicherungsautomat Typ A, B, C -Schutzschalterklemmen Typ 8 WA101110 Befestigungslaschen für Schraubbefestigung (Bestell-Nr.: 3RB 1900-0B).Weitere Daten und Bestell-Nr. für Zubehör siehe Katalog NSK.ZubehörSchützsicherheitskombination 3TK2807DIN EN 60439 Teil 1/ VDE 0660 Teil 500 (04.94)BetriebsanleitungBestell-Nr.: 3ZX1012-0TK28-7AA1Operation permissible in switchgear cabinet with degree of protection IP 54 only!-EMERGENCY OFF circuits-Circuits for monitoring protective devices (e.g. protective screens)-Circuits requiring controlled stopping as defined by DIN EN 60204-1, VDE 0113 Part 1: (1998-11), Stop-Category 1.In the case of equipment whose supply voltage is the same as the control voltage, the instructions given in DIN EN 60204-1, VDE 0113 Part 1: (1998-11), Point 9.1.1, must be followed!The internal control circuit of the contactor safety combination is designed according to DIN EN 60204-1, VDE 0113 Part 1: (1998-11), para. 9.4.2.2, so that in the case of a fault in one of the contactor relays the function of the safety circuit is maintained. The supply voltage must meet the require-ments of the DIN EN 60204-1, VDE 0113 Part 1: (1998-11) (the terminals “A2“ must be connected to that side of the control current circuit which is linked to the protective conductor system). The contacts of the contactor relays are checked for proper opening and closing in every ON and OFF cycle of the machine to be switched. This is, for instance, done by:-connecting and disconnecting the control voltage with the main switch -activating and deactivating the EMERGENCY-OFF unit -opening and closing of the protective screen.For circuit diagrams and connection examples , see Fig. III :a Internal circuit diagram (DC control), schematic diagram b Protective door circuit (2-channel)c EMERGENCY OFF circuit (2-channel)d Protective door circuit (2-channel)Automatic starting with positively opening switches.e EMERGENCY OFF circuit (2-channel with a 3TK29... supplementarymodule).Note: Single-channel control of the contactor safety combination is possi-ble by conneting the protective device between X1 and X3; X5. A link must be inserted between X3; X5.The external control circuit connections are shown for example only; the actual connections must be defined by the user on the basis of a risk assessment.Further applications available upon request.For dimension drawings (dimensions in mm), see Fig. I .Minimum clearances from earthed parts on the sides: 3 mm (see Fig. IIa ).Connection, see Fig. IIb .Sealed cover, see Fig. IIc .Cover the contactor safety combination during installation if foreign particles, such as swarf, can fall onto it. Install contactor safety combinations in a housing if they are exposed to dirt, dust or aggressive atmospheres.Cleaning: Remove dust with a vacuum cleaner.Operating states of the unit:“LINE“ indicates that voltage is applied to the unit.“CHANNEL 1“ and “CHANNEL 2“ light up when the ON button is pressed and the EMERGENCY OFF circuit or protective door circuit is closed.WARNING:HAZARDOUS VOLTAGECAN CAUSE ELECTRICAL SHOCKAND BURNS.DISCONNECT POWER BEFORE PROCEEDING WITH ANY WORK ON THIS EQUIPMENT.ApplicationFunctions and connectionsInstallationOperationthe event of an interference voltage occuring in the supply or signal cables.The guidelines on the handling of electrostatic sensitive devices (ESDs) must be followed. Earthing sleeves must be used!Short-circuit protection for signal circuit and enable circuit:No-weld fuse protection at short-circuit current -Fuse-links Fusing of contactor safety combination:-M.C.B., type G -M.C.B., type A, B, C -Protective circuit-breaker terminals type 8 WA101110 fixing lugs for screw fastening (Order No.: 3RB 1900-0B).For further data and order numbers for accessories see Catalog NSK.AccessoriesContactor Safety Combination3TK2807DIN EN 60439 Part 1/ VDE 0660 Part 500 (04.94)InstructionsOrder No.: 3ZX1012-0TK28-7AA12IIIaIII aIIbIIc2x(1 ... 2,5 mm 2)1x4 mm 2102x(0,75 ... 1,5 mm 2)0,8x5 ... 6 mm0,8 ... 1,2 Nm/7 ... 11 lb.inR1UH1K1K2K3K4K1K3H3K2tH2tK1K3K1K2H4K4K5H5K3K2K1K5K4978777655343332313142434445466788898X5X3X1A1 (+)A2 (-)X2X4K5III bIII cK3K2K1K5K4978777655343332313142434445466788898X5X3X1A1 (+)F1A2 (-)X2X4KM1KM2(MC)KM1KM2NL1/L+N;L-L1L2L3M(MC)KM1KM2F2F3F4F5F6F7III dIII eTechnische Änderungen vorbehalten.Subject to change without prior notice.© Siemens AG 1995Bestell-Nr./ Order No.: 3ZX1012-0TK28-7AA1Printed in the Federal Republic of GermanyTechnical Support:Tel: ++49 (0) 9131-7-43833 (8°° - 17°° MEZ)Fax: ++49 (0) 9131-7-42899E-mail: NST.technical-support@erl7.siemens.de Internet: www.ad.siemens.de/support。