SWAN在线硅表瑞士SWAN水质分析仪、SWAN变送器、SWAN温度传感器、(询,价—13—77-48—16—120 –吴-工)SWAN流量计、SWAN钠离子分析仪、SWAN在线硅表、SWAN电导率表pH / ORP MeasurementSignal inputs galvanically separated.Input resistance: > 1013pH measurementMeasuring range: 0.00 to 14.00 pHResolution: 0.01 pHReference temperature: 25 °CORP measurementMeasuring range: -500 to +1500 mVResolution: 1 mVTemperature compensationsautomatic, according to:- Nernst (for potable water and wastewater)- Nernst with non-linear solution compensation (for high purity water) - Nernst with linear compensation with selectable coefficient (for highpurity water)Calibration solutions tableProgrammable table for pH buffers and ORP calibration solution.Sensor monitoringIndication of glass breakage and line disconnection.Temperature measurementwith SWAN Pt1000 sensor.Measuring range: -30 to +130 °CResolution: 0.1 °CSample flow measurementwith digital sample flow meter.Transmitter Specifications and FunctionalityElectronics case: Cast aluminumProtection degree: IP 66 / NEMA 4XDisplay: backlit LCD, 75 x 45 mmElectrical connectors: screw clampsDimensions: 180 x 140 x 70 mmWeight: 1.5 kgAmbient temperature: -10 to +50 °CHumidity: 10 - 90 % rel., non cond.Power supplyVoltage: 100 - 240 VAC ( 10 %), 50/60 Hz ( 5 %)or 24 VDC, ( 10 %)Power consumption: max. 30 VAOperationEasy operation based on separate menus for “Messages”, “Diagnostics”, “Maintenance”, “Operation” and “Instal-lation”.User menus in English, German, French and Spanish.Separate menu specific password pro-tection.Display of process value, sample flow, alarm status and time duringoperation.Storage of event log, alarm log and cal-ibration history. Storage of the last 1’500 data records in logger with selectable timeinterval.Real-time clock with calendarFor action time stamp and preprogram-med actions.Safety featuresNo data loss after power failure, all data is saved in non-volatilememory.Overvoltage protection of in- and out-puts. Galvanic separation ofmeasuring inputs and signal outputs.Transmitter temperature monitoringwith programmable high/low alarm lim-its.1 Alarm relayOne potential free contact for summary alarm indication for programmable alarm values and instrument faults.Maximum load: 1A / 250 VAC1 InputOne input for potential-free contact.Programmable hold or remote off func-tion.2 Relay outputsTwo potential-free contacts program-mable as limit switches formeasuring values, controllers or timer for system cleaning withautomatic hold function.Max. load: 1A / 250 VAC2 Signal outputs (3rd optional)Two programmable signal outputs for measured values (freely scaleable, lin-ear or bilinear) or as continuous control output (controlparameters programma-ble).Current loop: 0/4 - 20 mAMaximum burden: 510Control functionsRelays or current outputs programma-ble for 1 or 2 pulse dosing pumps,so-lenoid valves or for one motor valve.Programmable P, PI, PID or PD control parameters.1 Communication interface (option)- RS232 interface for logger download to PC with SWANTerminal - RS485 interface (galvanically sepa-rated) with Fieldbus protocolModbus or Profibus DP- 3rd Signal output- USB interface。
硅酸盐连续测定仪操作手册 COPRA SILICA 96-251011ANALYTICAL INSTRUMENTSSwan Analytical Instruments AG CH-8616 Riedikon / Uster 目录1.1 概述1.2 工作原理1.2.1 测量原理1.2.2 在线操作2 安装2.1 安装要求2.2 样水要求2.3 拆箱2.4 安装2.5 接线2.6 安装压力棒2.7 启动3 显示屏与键盘3.1 显示屏3.2 键盘4 模式设置4.1 串行接口 (RS232)4.2 FIELDBUS/MODEM4.3 打印输出4.4 记录器4.5 校准4.6 测量参数4.7 选项4.8 维护5 用户模式5.1 手工取样5.2 硅表的限位5.3 打印机5.4 记录器5.5 系统5.6 诊断6 维护6.1 维护时间表6.2 更换泵管6.3 配制试剂6.4 清洗试剂过滤器6.5 更换阴离子交换柱6.6 电磁阀的维护6.7 更换通道选择阀6.8 维护之后的启动6.9 测量中断/完全停运及拆卸仪器6.10 错误信息警告仪表符合DIN57411 part 1/VDE 041 part 1、“电子测量仪保护措施”,并且在无故障条件下出厂。
为了保持这种无故障状态和保证无操作错误,用户必须重视所有的警告并且严格按照《操作手册》操作。
严禁不接地。
外部或内部保护地线的断裂或松弛可能会导致危险。
当需要进行电气检修时必需在未通电状态下。
打开仪表或移动其部件时须小心,连接应紧固。
检修须由指定人员进行。
若仪表不能正常运行,就必须切断所有电源,并停止操作。
如有下述情况发生,不能进行安全操作:- 在运输或安装过程中明显损坏。
- 仪表不工作。
- 在不良环境下储存期过长仪表附件的任何连接都必须按照IEC 950/EN 60950,UL1950或UL478标准。
注意:没有试剂仪表不能工作。
试剂可以在Swan公司各地的经销商处购买。
SWAN电导率表瑞士SWAN水质分析仪表公司致力于研究、开发和生产各类水质分析仪表及远程分析系统。
其产品涉及高纯水、超纯水、工业净水、饮用水及污水处理系统,应用于世界各地的半导体、电力、石化、制药、自来水、环保等工业领域。
SWAN产品技术领先、测量精度高、可靠性好、操作简便、维护量少、使用寿命长,在国际同类产品中处于领导地位,是高品质的象征,国际知名品牌。
瑞士SWAN公司建立了全球性的销售及技术服务网络,以其优质的产品和最优化的服务赢得了极高声誉。
(询&价&1377 4816 120—吴=工)N300钠测量电极CNA-87.720.010适用于所有型号的钠表支N301钠参比电极CNA-87.840.100适用于所有型号的钠表支N303钠pH电极CNA-87.150.100仅适用于AMI Sodium P/A型钠表支N400钠活化液包CNA-87.729.010含1瓶100ml液体和1瓶少量固体套N401钠电解液CNA-87.892.400用于钠参比电极;100ml瓶N402钠标准液CNA-85.141.400100ml瓶N302钠温度电极CNA-87.027.020适用于所有型号的钠表;FAM/AMI Hydrazine型联氨;FAM/AMI Trides型余氯;带0.8米固定电缆支N410钠空气过滤器CNC-82.880.0102个/套套N419钠气泡探测器CNA-87.932.020仅适用于AMI Sodium P钠表个备品备件 [Monitor AMI Phosphate-II B]S400泵管CNA-86.190.010适用于硅表和磷表;1粗,4细套S408试剂管过滤芯CNA-82.811.021适用于硅表和磷表;12个套S413磷试剂CNA-85.420.200仅适用于磷表;1套/月套S404零点校准阀CNA-82.511.010适用于硅表和磷表个S405电磁阀备件CNA-82.519.020适用于硅表和磷表;包含:垫片、弹簧及玻璃棒套S406通道切换阀CNA-82.541.010适用于硅表和磷表个S411磷标准液CNA-85.143.400仅适用于磷表;1000ppm,100ml瓶S416试剂管CNA-86.190.011适用于硅表和磷表;4根,含试剂管过滤头套S417虹吸管、排气管CNA-86.190.012适用于硅表和磷表;5根套S419通道切换阀管路CNA-86.190.014适用于硅表和磷表;6根套。
swan硅表工作流程下载温馨提示:该文档是我店铺精心编制而成,希望大家下载以后,能够帮助大家解决实际的问题。
文档下载后可定制随意修改,请根据实际需要进行相应的调整和使用,谢谢!并且,本店铺为大家提供各种各样类型的实用资料,如教育随笔、日记赏析、句子摘抄、古诗大全、经典美文、话题作文、工作总结、词语解析、文案摘录、其他资料等等,如想了解不同资料格式和写法,敬请关注!Download tips: This document is carefully compiled by theeditor.I hope that after you download them,they can help yousolve practical problems. The document can be customized andmodified after downloading,please adjust and use it according toactual needs, thank you!In addition, our shop provides you with various types ofpractical materials,such as educational essays, diaryappreciation,sentence excerpts,ancient poems,classic articles,topic composition,work summary,word parsing,copy excerpts,other materials and so on,want to know different data formats andwriting methods,please pay attention!深入解析:SWAN硅表的工作流程SWAN硅表,作为一种先进的科技产品,主要用于水质监测和环境检测,其高效、精准的工作流程是其独特优势的重要体现。
荣成市石岛热电联产项目外供蒸汽凝结水回收处理系统技术规范书需方: 荣成市昊阳热电有限公司设计方: 山东省鑫峰工程设计有限公司2016年6月目录附件1 技术规范书 (1)附件2 供货范围 (13)附件4 技术服务和设计联络 (19)附件5 包装、保管及组装要求 (22)附件6 差异表 (23)附件7 400V配电装置技术要求 (23)附件1 技术规范书1总则1.1本技术规范书适用于荣成市石岛热电联产项目外供蒸汽凝结水回收处理系统设备的招标。
它提出了该系统的设计、制造、施工、调试和试验等工程总承包的技术要求。
1.2本技术规范书提出的是最低限度的技术要求,并未规定所有的技术要求和适用的标准,供方应提供一套满足本技术规范书和所列标准要求的高质量产品及其相应服务。
对国家有关安全、环保等强制性标准,必须满足其要求。
1.3如未对本技术规范书提出偏差,需方将认为供方提供的设备符合本技术规范书和标准的要求。
偏差(无论多少)都必须清楚地表示在本技术规范书中的附件8“差异表”中。
1.4供方须执行本技术规范书所列标准。
如有矛盾,按较高标准执行。
供方在设备设计和制造中所涉及的各项规程、规范和标准必须遵循现行最新版本的标准。
1.5 从签订合同之后至供方开始制造之日的这段时期内,需方有权提出因规程、规范和标准发生变化而产生的一些补充修改要求,供方应遵守这些要求,且不发生价格的变更。
1.6 供方对成套系统设备(含辅助系统与设备)负有全责,即包括分包(或采购)的产品。
分包(或采购)的产品制造商应事先征得需方的认可。
1.7设备采用的专利涉及到的全部费用均已包含在设备报价中,供方保证需方不承担有关设备专利的一切责任。
1.8只有需方有权修改本技术规范书。
合同谈判将以本技术规范书为蓝本,并列入需方认可的技术偏差,经修改后最终确定的技术规范书将作为订货合同的技术附件,并与合同正文具有相同的法律效力。
双方共同签署的会议纪要、补充文件等也与合同正文具有相同的法律效力。
精处理系统SWAN在线硅表故障诊断一.常规检查2018年8月7日,化学运行人员监测到#3机组精处理在线硅表数据异常并填写缺陷。
8月7日热工维护人员对该表进行常规检查发现:1.硅表测量值高达30ppb,正常控制值(0—10)ppb,期望值(0—5)ppb.2. 仪表的零点频率低至15万(正常应在20万以上)。
3. 零点标定自动手动都无法完成。
二.处理过程SWAN 硅表采用的是光度法,出现峰值的最大可能是由于气泡或杂质对光度计测量的影响,而有时气泡无法用肉眼识别,或停留在比色皿死角内,并反复对测量产生影响,针对这种情况,8月7日至17日,热工人员进行如下操作逐步判断漏点及故障:1.肉眼排查:首先用肉眼逐一检查各个样水管及试剂管中是否有气泡并排查漏点。
2.杂质排查:5%浓氨水清洗——把所有试剂管从试剂桶中取出,放入5%浓氨水中,标液瓶中置5%浓氨水,程序同时走第五通道冲洗,反复清洗多次,测量值仍高达30ppb,零点频率15万,零点标定仍没通过,排除试剂杂质的可能。
3.气泡排查:1)蠕动泵加速:快速填充第一通道(零点标定默认走第一通道)反复进行若干次,测量值仍高达30ppb,零点频率15万,零点标定仍没通过。
2)更换泵管:更换泵管后,程序走系统填充时蠕动泵停止转动,待运行一天后,程序填充正常进行,测量值仍高达30ppb,零点频率低至15万(正常应在20万以上),零点标定仍没通过。
说明蠕动泵老化,泵速不稳定。
4.试剂排查:1)把所有试剂管从试剂桶中取出,放入纯水中(若气泡或杂质是由试剂引起,此时读值应为0)测量值大概10ppb;2)更换精处理#3#4机高混硅表试剂,#3机高混硅表测量值仍高达30ppb,零点标定仍无法通;#4机高混硅表测量值(0—10)ppb 正常范围内,零点标定正常通过。
排除试剂有问题的可能。
5.样水排查:把样水进样管(6通道转换阀前端)放入纯水中(若气泡或杂质是由样水引起,此时读值应为0)测量值大概20ppb;排除样水有问题的可能。
药品:
SiO2标液100ppb 2L
pH标定液6.86,9.18各2L
PNa4,PNa5各2L
操作
硅表:
一、启动
1.3.2.2.1,确认,填充药剂,完毕。
2.调节左下方流量,至10L/h左右为宜。
二、标定
1.进入菜单3.1.1
2.关闭右上角进液阀门,待进液瓶排空。
3.倒入100ppb标液,确认菜单,等待。
4.待自动标定排液完毕后,完成,此时斜率应为1.
pH表(同电导):
一、启动
1、装入电极,给电极打吊瓶(电极一起的药瓶)。
2、进入菜单5.2.1.40设置量程
3、电极若长期停用,应将盖帽充入除盐水,给电极套上盖帽保护电极。
二、标定
1、进入菜单3.1.2
2、将探头放入6.86标液中,确认,等待标定完毕。
3、冲洗探头,放入9.18标液中,确认,等待。
4、最后确认,退出。
钠表:
标定类似pH
1、进入菜单3.1.2
2、将PNa5倒入标液瓶,将标液瓶装在表中间的旋转口上,拧好后,旋转瓶子倒置,确认开始。
3、完毕后,倒入PNa4,同上。
4、确认,退出,完毕。
COPAR SILICA 硅酸盐连续测定仪安装启动步骤检查工作电压是否符合仪表额定值!不要开启电源,按照2.7章节所讲的去做后!安装位置(2.1):选择一个方便调整和方便打开仪表前门的地方,仪表位置必须满足以下连接要求:- 交流电源出口接地,至少100~230VAC,50/60Hz/85 VA。
- 每通道样水管线(4x6 mm)满足至少10 ml/min的流速和0.3 - 3 bar(4 - 43 psi)的气压。
- 废水管线(14x20 mm (1/2"))常压排放,2 - 4通道仪表。
安装(2.4):- 垂直安装仪表。
- 连接样水管路、安全通道、废水线路。
- 安装离子交换柱电气连接(2.5)- 连接所有外设,如限位开关、电流回路和打印机等。
- 连接电源线,不要接通电源。
泵管(2.6)- 安装压力棒,将泵管紧压在泵体上。
样水流(2.7)- 检查样水是否无滴漏,管路是否通畅(样水中不能有污物)。
- 打开样水控制阀。
调整流量大小。
样水最终必须连续地从废水孔排出。
标准(2.7)- 用优质(无硅)水彻底清洗标准瓶。
- 根据你的需要配制标准硅溶液,最好直接在标准瓶内配置。
- 安装试剂瓶。
试剂(2.7)- 根据配方,用有标签的试剂桶配制试剂。
- 根据颜色代码将试管连接到分配器(在泵的正下方)。
- 根据颜色代码将试管放在试剂桶内。
兰色钼酸红色硫酸无色草酸黑色还原剂(硫酸亚铁铵)接通电源(2.7)- 接通电源。
- 试管被自动注满,同时反应试管和光度计被加热到运转温度。
仪表设置(4 & 5)- 设置外接设备的所有参数(界面、打印机、记录器和其它选项)。
- 设置仪表运转参数(自动校准、限位、打印输出和记录器)。
2 安装2.1 安装要求选择一个便于靠近仪表和试剂桶的地方,仪表位置必须满足以下连接要求:电源:100~230VAC+15%,85VA进水口:适配4 x 6 mm FEP管的Serto管2支到4支排水口:1/2" (14 x 20 mm) 软管,它有足够的容量可以在环境大气压下自由排放警告:仪表中所有连接必须遵循章节2.5和附录中提到的最小化系统规范。
硅磷表
一、测量原理
朗伯-比耳定律A=kcb
当一束单色光通过均匀溶液时,其吸光度与溶液的浓度和厚度的乘积成正比。
A 是吸光度,A=lgI0/lgI
k 是比例常数,与入射光波长、物质的性质和溶液的温度有关。
c 是溶液的浓度。
b 是流通池的厚度。
影响硅、磷测量的主要因素:
1.光度计波长
2.反应温度
二、波长的选择
✓物质的颜色是由于对不同波长的光具有选择性吸收作用而产生的。
如图所示,硅钼蓝对波长815nm的吸收最大。
✓SWAN硅表选择波长为815nm的单色半导体冷光源(LED),其特点是测量准确、灵敏度高、稳定性好;光源长寿命。
但需要温度恒定。
SWAN硅表将光度计置于45℃恒温反应室中。
三、温度对化学反应的影响
化学反应速度与温度有关。
在生成硅钼蓝的一系列化学反应中,速度最慢的一步是
生成硅钼黄的反应,常温下,需要10分钟以上的时间。
如图所示,当温度达到45℃时,反应可在2分钟内完成。
SWAN 硅表45℃恒温反应室,确保反应条件恒定,而且每两次测量间隔最小:只
有2.5分钟!
SWAN 硅表构成(一)
2
4 6 8
10
5
10
15 20
Seconds
% of Endvalue
12
27 45
样水进入和多通路系统(2、4、6通道)
——样水溢流,保持新鲜样水。
SWAN硅表构成(一)
样水进入和多通路系统(2、4、6通道)
——样水溢流,保持新鲜样水。
SWAN硅表构成(二)
样水和试剂加入系统——SW AN设计的数控机械式蠕动泵
✓泵管压力恒定,确保长寿命,质保期1年。
✓蠕动泵转速可控,延长泵管寿命。
可达1.5-2年。
✓可加速正转,快速新试剂填充。
✓可加速反转,快速排空试剂。
避免污染。
四、SW AN硅表构成(三)
45℃恒温反应测量室
✓消除外界温度对测量值的影响确保测量准确、稳定;
✓测量快速,每一次测量周期为2.5min。
四、SW AN硅表构成(四)
虹吸排液系统
✓彻底干净,减少交叉污染;
✓无机械易损件。
四、SW AN硅表构成(五)
校准及离线测量系统
✓自动或手动零点校准;
✓自动或手动斜率校准;
✓自动或手动空白校准(选项);
✓离线测量功能。
四、SW AN硅表构成(六)
断样水及断试剂检测系统
✓气泡探测器;
四、SW AN硅表构成(七)
断样水及断试剂检测系统
✓样水和试剂频率检测
✓815nm LED冷光源,长寿命。
✓45℃恒温反应室。
测量快速、稳定。
✓全自动零点、斜率校准。
✓智能型蠕动泵。
长寿命。
功能强。
✓长寿命泵管(1.5—2年)
✓虹吸式排液。
✓离线测量功能
✓断样水和断试剂报警
✓高质量的变送器和完备的信号输出。