SIEMENS DriveMonitor软件对6SE70变频器参数的上传与下载培训(高端培训)
- 格式:pptx
- 大小:1.43 MB
- 文档页数:16
1.(P060=4)3. (P060=5)4.1. (P060=2)2.(((P060=2)6-1P060=6 060=8)6SE70..P072P073P366)Select "Fixed settings" menuStart parameter reset0: Parameter reset1: No parameter changeSelect desired factory setting0: Standard1: Standard with OP1S2: Cabinet unit with OP1S (BICO1) or terminal strip (BICO2)3: Cabinet unit with PMU (BICO1) or terminal strip (BICO2)4: Cabinet unit with NAMUR terminal strip (SCI)Note:This parameter was correctly set prior todelivery of the unit and only needs to beGrant parameter access6:Parameter changes permitted via PMU and serial interfaceUnit carries out parameterreset and then leaves the"Fixed settings" menu6SCom1(OP1SOP1S(SCI)P366OP1S PMU(SCI)(Src=6-2()11=KKxxxx==(4000 0000h = 100 %)6.2.16-352(P366=0)SIMOVIS3.SIMATIC)SCom2(CBP)Automation unit(e. g. SIMATIC S7)LaptopOP1SOperating modeIndividual operationBus operationType of constructionCompact, chassisCompact, chassisTerminalOperating modeIndividual operationType of constructionCompact, chassisTerminalX300(SCom1)U SSUSS via RS232Operating modeBus operationType of constructionOptional board CBxe. g. CBP for ProfibusTerminale. g. X448for CBPb us-sp ec i f ic,,,X448RS485OP1S6-3P704))SIMOVISP060OP1S SIMOVISP0606CUVCP1096-4)P116, P128, P215, P216, P217, P223, P235, P236, P240, P259,P278, P279, P287, P295, P303, P313, P396, P471, P525, P602,P603.(P060=3)1. ()2.3.(P060=0)BICO1♦♦/(xxxr.m.sDC(VdmaxIEC()11/(v/f+(P130=11)1(f-)4(n-)(P130=11)5P151=1024/(P100=3,4,5).200kW.()IECNEMA Hp%rpm()1246UL1s.(P384.2)100%.(PMU+MOP123MOP4SIMATIC)5)6)7SCom1PMU)USSSIMOLINKPROFIBUSP366=0)1LA50632-6-10-1LA5063480780----1LA5070480600720---1LA5073480600720---1LA5080480600720---1LA5083600600720---1LA5090300540720720--1LA5096360660720840--1LA5106480720720960--1LA5107-720-960--1LA5113840660780720--1LA5130660600780600--1LA5131660600----1LA5133-600840600--1LA5134--960---1LA516390011401200720--1LA5164900-----1LA516690011401200840--1LA518315001800----1LA5186-180024002700--1LA52061800-2700---1LA52071800210027003000--1LA6220-2400-3300--1LA62232100240030003300--1LA62532400270030003600--1LA62802400300033003900--1LA62832400300033003900--1LA63102700330036004500--1LA6313-330036004500--1LA831.2100240027002700300030001LA835.240027003000300033003300 P383T11LA-/1LL4-8-12-1LA51PH6101PH6131PH6161PH6181PH6201PH622T1(s)150018002100240024002400n=1150rpm T1=1200n100132160180225T1(s)15001800210024002400180225T1(s)180018001LA71PH61PA61PL6(P351)(P353)(P060=5)P35350.00 Hz(P353=P352x60/P109)P113P113()A080!(P368)P368=+P368 = 2FSetp +P368 = 3MOP +P368 = 4USS P368 = 7OP1S +FSetpP554.1Src ON/OFF1B0005B0022B0022B0022B2100B2100P555.1Src OFF21B0020B0020B0020B21011P561.1Src InvRelease 1B00161111P565.1Src1 Fault Reset B2107B2107B2107B2107B2107B2107P567.1Src3 Fault Reset 0B0018B0018B001800P568.1Src Jog Bit00000B2108B2108P571.1Src FWD Speed 1111B2111B2111P572.1Src REV Speed 1111B2112B2112P573.1Src MOP Up B000800B001400P574.1Src MOP Down B000900B001600P580.1Src FixSetp Bit000B0014000P581.1Src FixSetp Bit100B0016000P590Src BICO DSet 000000P651.1Src DigOut1B0107B0107B0107B0107B0107B0107P652.1Src DigOut2B0104B0104B0104B0104B0104B0104P653.1Src DigOut30B01150000P654.1Src DigOut4(16-4000h=100%)KKxxxx=(32-4000 000h=100%)6.3.1CUVCSelect "Power section definition" menuReturn to parameter menuInput the code number for the unit concernedThe code number is allocated to the order numbers (MLFB).The order number can be read off the unit's rating plate.The list of units is on the following pages.P071(MLFB)In [A]PWE6SE7016-1EA61 6.136SE7018-0EA618.096SE7021-0EA6110.2116SE7021-3EB6113.2186SE7021-8EB6117.5256SE7022-6EC6125.5356SE7023-4EC6134.0426SE7023-8ED6137.5466SE7024-7ED6147.0526SE7026-0ED6159.0566SE7027-2ED6172.066 230 V3AC 380 V600 VIn [A]PWE6SE7016-1TA61 6.146SE7018-0TA618.0106SE7021-0TA6110.2126SE7021-3TB6113.2196SE7021-8TB6117.5266SE7022-6TC6125.5366SE7023-4TC6134.0436SE7023-8TD6137.5476SE7024-7TD6147.0536SE7026-0TD6159.0576SE7027-2TD6172.067 310 VDC 510 V810 VIn [A]PWE650 VIn [A]PWEIn [A]PWESelect "Board configuration" menuSCB protocol0: SCI1: USS 4-wire2: USS 2-wire3: Peer-to-PeerSCB inserted ?noEnter the CB parameters 1 to 11 necessary for the insertedcommunications boards CBxThe necessary CB parameters and their significance can be CBx inserted ?SCI12311CBCBxms2340 m7.5.SIMOLINK(CBxr8263Br8265Dr8267FT300SCB13901101291391491691()121SCB2131T300134CBX1151EB2(V/f()♦S1(n(M4%♦P103%)P103(P101)(800kW)(22kW)(U=P101n=P108♦P107P109))♦(1-P108 / 60xP109/P107)(800 kW)(22 kW )10%(P115=2)20()100%(±10%)P1078HzP101P108P108=((8Hz-P107old )x60/P109)+P108old0=dv/dtDC10NEMA()12()/v/f2)3(f)4(n)5200 kW(P100A)(%)P103=0(IECNEMA Hp)NEMAHzP107)()1)2)41112132150)1(/(FLM)4-/)V()P353P352T1 (19)T0UL?(F020s300%%P352P352P4621=P4641=P20 sAT1A080!(°009)%A08020sFxxx(V/fP350(()P88;P155P312P354♦P115=2P115=2• P103P121P127P349P284P316♦4P103n/f P116P235P240(P115=2,3)P095=P100=P101 (109)P339=P340=P357=♦P0680)♦P340 2.5 kHzP34290%f-(P100=3)n-(P100=4)P315 = EMF Reg.Kp 2 x Kp KpP223 = Smooth.n/f(act)≥ 0 ms≥ 4 msP216 = Smooth. n/f(pre)≥ 4.8 ms≥ 0.0 msP222 = Src n/f(act)KK0000KK0000 (KK0091)Tn(P240))。
6SE70系列传动装置参数备份下装DriveMonitor 软件的安装要求WIN95/98/NT/2000/ XP 以上操作系统.首先在PC 机上运行WinMount.exe安装虚拟光驱,虚拟光驱中打开DriveMonitor54.iso: 选择安装文件选择安装语言为英语依此选NEXT , 在安装项目中选择默认或是选择Drivemonitor , Micmaster ,Simovert ,Simoreg 项目. 然后即可顺利安装.注意: 第一次打开Drivemonitor 软件, 界面显示的语言可能是德语. 需要在工具栏(EXTRAS / SPRACHE )进行语言选择英语. 重新打开即可.如图所示:Drivemonitor 与传动装置建立连接MA STERDRIVE 和SIMOVERT (6SE70系列)通讯的RS232 电缆连接图:Drivemonitor 在线设置打开tools , 选中online setting 如图所示:依此设定,如图所示1) USS 通讯2) COM 口选择( COM1 )3) 波特率设定(9600K )在线连接可以选择两种在线方式: RAM / EEPROM 如图所示:建议直接选择“EEPROM”方式进行在线连接。
参数备份新建项目1: 双击Drivemonitor 快捷图标打开画面2: 通过file / new / base on factory setting or empty parameter set 新建一个项目.3: 根据弹出的画面进行设置,如图所示:选FILE / UPLOAD/BASIC DEVICE COMPLETE (如图);在线方式: EEPROM1) 根据实际装置的类型选择UNIT TYPE (本例是Compact plus unit )2) UNIT VERSION 应与装置的实际版本一致, 可以读参数R069得到3) BUS ADDRESS 应与装置一致,可以读参数P918 得到4) PZD 数量设24:逆变装置、整流装置的类型选择,如图所示::装置内部参数设定逆变器:使用装置面板上的插口(X300 端口)连接到COM1P53=6 访问级别)P60=7 (通讯方式)P700.1=0 ( USS 地址)P701.1=6 ( 通讯波特率9600K)P702.1=127整流器:P51=3 访问级别)P52=3 (允许读写)P53=6 (通讯方式)P683.001=0 (通讯接口定义)P684=6 ( 通讯波特率9600K)切记:修改前必须记下原参数,备份或下装完成后必须恢复。
西门子6se70系列变频器参数设置一加减速时间加速时间就是输出频率从0 上升到最大频率所需时间,减速时间是指从最大频率下降到0 所需时间。
通常用频率设定信号上升、下降来确定加减速时间。
在电动机加速时须限制频率设定的上升率以防止过电流,减速时则限制下降率以防止过电压。
加速时间设定要求:将加速电流限制在变频器过电流容量以下,不使过流失速而引起变频器跳闸;减速时间设定要点是:防止平滑电路电压过大,不使再生过压失速而使变频器跳闸。
加减速时间可根据负载计算出来,但在调试中常采取按负载和经验先设定较长加减速时间,通过起、停电动机观察有无过电流、过电压报警;然后将加减速设定时间逐渐缩短,以运转中不发生报警为原则,重复操作几次,便可确定出最佳加减速时间。
二转矩提升转矩提升又叫转矩补偿,是为补偿因电动机定子绕组电阻所引起的低速时转矩降低,而把低频率范围f/V 增大的方法。
设定为自动时,可使加速时的电压自动提升以补偿起动转矩,使电动机加速顺利进行。
如采用手动补偿时,根据负载特性,尤其是负载的起动特性,通过试验可选出较佳曲线。
对于变转矩负载,如选择不当会出现低速时的输出电压过高,而浪费电能的现象,甚至还会出现电动机带负载起动时电流大,而转速上不去的现象。
三电子热过载保护本功能为保护电动机过热而设置,它是变频器内CPU 根据运转电流值和频率计算出电动机的温升,从而进行过热保护。
本功能只适用于“一拖一”场合,而在“一拖多”时,则应在各台电动机上加装热继电器。
电子热保护设定值(%)=[电动机额定电流(A)/变频器额定输出电流(A)]×100%。
四频率限制即变频器输出频率的上、下限幅值。
频率限制是为防止误操作或外接频率设定信号源出故障,而引起输出频率的过高或过低,以防损坏设备的一种保护功能。
在应用中按实际情况设定即可。
此功能还可作限速使用,如有的皮带输送机,由于输送物料不太多,为减少机械和皮带的磨损,可采用变频器驱动,并将变频器上限频率设定为某一频率值,这样就可使皮带输送机运行在一个固定、较低的工作速度上。
西门子变频器6SE70参数简单设置方法1.1 出厂参数设定P052=1 选定建立工厂设置功能按下“P”键,运行显示“001”,根据P077 对所有参数进行工厂设置。
结束工厂设置后,显示“008”或“009”。
1.2 标准应用设置P051=2 存取级“标准模式”P053=7 参数设置权限使能“CB+PMU+SST1&OP”P052=5 传动系统设置P071=400 电源电压P052=21 选择电路识别功能在PMU 按下“I”键,进行电路识别,约需10s。
如果出现故障,则必须重新识别。
(r947,r949 显示故障码和故障值)P052=0 选定返回功能。
1.3 其他设置P554.1=P555.1=1010 由PMU 输出分闸指令,在分闸前不等待中间回路电压放电至1.35×P071 的20%。
P603.1=1001 端子17/18 故障输出P555.1=1005 端子13 急停P70 设置MLFB2 26SE70 变频装置调试步骤一.内控参数设定1.1 出厂参数设定P053=7 允许CBP+PMU+PC 机修改参数P60=2 固定设置,参数恢复到缺省P366=0 PMU 控制P970=0 启动参数复位执行参数出厂设置,只是对变频器的设定与命令源进行设定,P366 参数选择不同,变频器的设定和命令源可以来自端子,OP1S,PMU。
电机和控制参数未进行设定,不能实施电机调试。
1.2 简单参数设定P60=3 简单应用参数设置,在上述出厂参数设置的基础上,本应用设定电机控制参数P071 进线电压(变频器400V AC / 逆变器540V DC)P95=10 IEC 电机P100=1 V/F 开环控制3 不带编码器的矢量控制4 带编码器的矢量控制P101 电机额定电压P102 电机额定电流P107 电机额定频率HZP108 电机额定速度RPMP114=0P368=0 设定和命令源为PMU+MOPP370=1 启动简单应用参数设置P60=0 结束简单应用参数设置执行上述参数设定后,变频器自动组合功能图连接和参数设定。
西门子6se70系列变频器参数设置一加减速时间加速时间就是输出频率从0 上升到最大频率所需时间,减速时间是指从最大频率下降到0 所需时间。
通常用频率设定信号上升、下降来确定加减速时间。
在电动机加速时须限制频率设定的上升率以防止过电流,减速时则限制下降率以防止过电压。
加速时间设定要求:将加速电流限制在变频器过电流容量以下,不使过流失速而引起变频器跳闸;减速时间设定要点是:防止平滑电路电压过大,不使再生过压失速而使变频器跳闸。
加减速时间可根据负载计算出来,但在调试中常采取按负载和经验先设定较长加减速时间,通过起、停电动机观察有无过电流、过电压报警;然后将加减速设定时间逐渐缩短,以运转中不发生报警为原则,重复操作几次,便可确定出最佳加减速时间。
二转矩提升转矩提升又叫转矩补偿,是为补偿因电动机定子绕组电阻所引起的低速时转矩降低,而把低频率范围f/V 增大的方法。
设定为自动时,可使加速时的电压自动提升以补偿起动转矩,使电动机加速顺利进行。
如采用手动补偿时,根据负载特性,尤其是负载的起动特性,通过试验可选出较佳曲线。
对于变转矩负载,如选择不当会出现低速时的输出电压过高,而浪费电能的现象,甚至还会出现电动机带负载起动时电流大,而转速上不去的现象。
三电子热过载保护本功能为保护电动机过热而设置,它是变频器内CPU 根据运转电流值和频率计算出电动机的温升,从而进行过热保护。
本功能只适用于“一拖一”场合,而在“一拖多”时,则应在各台电动机上加装热继电器。
电子热保护设定值(%)=[电动机额定电流(A)/变频器额定输出电流(A)]×100%。
四频率限制即变频器输出频率的上、下限幅值。
频率限制是为防止误操作或外接频率设定信号源出故障,而引起输出频率的过高或过低,以防损坏设备的一种保护功能。
在应用中按实际情况设定即可。
此功能还可作限速使用,如有的皮带输送机,由于输送物料不太多,为减少机械和皮带的磨损,可采用变频器驱动,并将变频器上限频率设定为某一频率值,这样就可使皮带输送机运行在一个固定、较低的工作速度上。