35米箱梁伸长值计算
- 格式:xls
- 大小:23.00 KB
- 文档页数:1
N1钢绞线k=0.0015A=139mmμ=0.25σ=P/A△X=σ*L/E局部张拉段孔道长度X(m)孔道夹角θ(rad)(kx+μθ)e-(kx+μθ)张拉端张拉力P(N)平均张拉力Pp(N)张拉应力σ(MPa)伸长值△X(mm)ab4.82300.00723450.992791606194396.226194396.2261398.5343.45904076bc3.9990.05796440.02048960.979718886192994.9414191031.18191374.325052.818423525cd8.500.012750.987330937189080.7889189080.78891360.2934455.929484249合计12.20694853N2钢绞线局部张拉段孔道长度X(m)孔道夹角θ(rad)(kx+μθ)e-(kx+μθ)张拉端张拉力P(N)平均张拉力Pp(N)张拉应力σ(MPa)伸长值△X(mm)ab5.82600.0087390.991299074194396.226194396.2261398.5344.178389274bc3.9980.073990960.024494740.975802822192704.7988190363.82461369.5239182.807875192cd7.500.011250.988813045188041.8864188041.88641352.8193275.203151258合计12.18941572N3钢绞线局部张拉段孔道长度X(m)孔道夹角θ(rad)(kx+μθ)e-(kx+μθ)张拉端张拉力P(N)平均张拉力Pp(N)张拉应力σ(MPa)伸长值△X(mm)ab6.82700.01024050.989811755194396.226194396.2261398.5344.896303394bc3.9980.08591040.02747460.972899394192415.6697189796.44011365.4420152.799506245cd6.500.009750.990297377187201.0884187201.08841346.770424.489234734合计12.1850443735m预应力箱梁钢绞线伸长值计算σ=1398.534MPa