第三节 塔体强度校核
- 格式:ppt
- 大小:453.50 KB
- 文档页数:23
上封头校核计算计算单位中航一集团航空动力控制系统研究所计算所依据的标准GB 150.3-2011计算条件椭圆封头简图计算压力P c 0.13 MPa设计温度 t 145.00 ︒ C内径D i 7000.00 mm曲面深度h i 1500.00 mm材料 Q345R (板材)设计温度许用应力[σ]t 183.20 MPa试验温度许用应力[σ] 185.00 MPa钢板负偏差C1 0.30 mm腐蚀裕量C2 2.00 mm焊接接头系数φ 0.85压力试验时应力校核压力试验类型液压试验试验压力值P T = 1.25P ct][][σσ= 0.1650 (或由用户输入)MPa压力试验允许通过的应力[σ]t[σ]T≤ 0.90 σs = 292.50MPa试验压力下封头的应力σT =φδδ.2)5.0.(eeiTKDp+= 37.18MPa校核条件σT≤[σ]T校核结果合格厚度及重量计算形状系数 K =⎥⎥⎦⎤⎢⎢⎣⎡⎪⎪⎭⎫⎝⎛+2ii2261hD = 1.2407计算厚度δh =KP DPc itc205[].σφ- = 3.68mm有效厚度δeh =δnh - C1- C2= 22.70mm 最小厚度δmin = 21.00mm 名义厚度δnh = 25.00mm 结论满足最小厚度要求重量9546.41 Kg压力计算最大允许工作压力[P w]=205[].σφδδtei eKD+= 0.81293MPa结论合格下封头校核计算计算单位中航一集团航空动力控制系统研究所计算所依据的标准GB 150.3-2011计算条件椭圆封头简图计算压力P c 0.15 MPa设计温度 t 145.00 ︒ C内径D i 7000.00 mm曲面深度h i 1500.00 mm材料 Q345R (板材)设计温度许用应力[σ]t 183.20 MPa试验温度许用应力[σ] 185.00 MPa钢板负偏差C1 0.30 mm腐蚀裕量C2 2.00 mm焊接接头系数φ 0.85压力试验时应力校核压力试验类型液压试验试验压力值P T = 1.25P ct][][σσ= 0.7489 (或由用户输入)MPa压力试验允许通过的应力[σ]t[σ]T≤ 0.90 σs = 292.50MPa试验压力下封头的应力σT =φδδ.2)5.0.(eeiTKDp+= 168.78MPa校核条件σT≤[σ]T校核结果合格厚度及重量计算形状系数 K =⎥⎥⎦⎤⎢⎢⎣⎡⎪⎪⎭⎫⎝⎛+2ii2261hD = 1.2407计算厚度δh =KP DPc itc205[].σφ- = 4.20mm有效厚度δeh =δnh - C1- C2= 22.70mm 最小厚度δmin = 21.00mm 名义厚度δnh = 25.00mm 结论满足最小厚度要求重量9546.41 Kg压力计算最大允许工作压力[P w]=205[].σφδδtei eKD+= 0.81293MPa结论合格内压圆筒校核 计算单位 中航一集团航空动力控制系统研究所计算所依据的标准GB 150.3-2011计算条件筒体简图计算压力 P c 0.14 MPa设计温度 t 145.00 ︒ C 内径 D i 7000.00mm 材料Q345R ( 板材 ) 试验温度许用应力 [σ]189.00 MPa 设计温度许用应力 [σ]t189.00 MPa 试验温度下屈服点 σs 345.00 MPa 钢板负偏差 C 1 0.30 mm 腐蚀裕量 C 2 2.00 mm焊接接头系数 φ0.85厚度及重量计算计算厚度 δ = P D P c it c 2[]σφ- = 3.04mm 有效厚度 δe =δn - C 1- C 2= 13.70 mm 名义厚度 δn = 16.00 mm 重量160562.78Kg压力试验时应力校核压力试验类型 液压试验试验压力值 P T = 1.25P [][]σσt = 0.7489 (或由用户输入)MPa 压力试验允许通过 的应力水平 [σ]T [σ]T ≤ 0.90 σs = 310.50MPa试验压力下 圆筒的应力 σT = p D T i e e .().+δδφ2 = 225.54 MPa校核条件 σT ≤ [σ]T 校核结果合格压力及应力计算最大允许工作压力 [P w ]= 2δσφδe t i e []()D += 0.62760MPa 设计温度下计算应力 σt= P D c i e e()+δδ2= 35.66 MPa [σ]tφ 160.65 MPa校核条件 [σ]tφ ≥σt结论 合格。
塔操作质量,kg m 0677532.973塔最大质量,kg m max 687711.773塔最小质量,kg m min 283255.3塔内径,mm D i 90009000塔体高度,mm H 130000烟囱高度,mm H 230000塔总高,mmH6000060000段号 项目代号12塔段长度h i 57008000厚度δe,i 2018壳体质量m 0125358.1832024.29内件质量m 0200保温层质量m 032428.23408平台、扶梯质量m 0426966241操作时塔内介质质量m 054352040液压试验时塔充液质量m w 3626700塔的操作质量m 0465686.3841673.29该段塔的最大质量m max 393152.3841673.29该段塔的最小质量m min30482.3841673.29代号12塔第i段操作质量,kg m i 465686.3841673.29第i段集中质量距地面高度,mmh i28509700一、塔基本参数二、分段质量1第i段当量集中质量49.90848251176.0837343塔顶部至第i段底截面高度,mm H i 6000054300第i计算段截面惯性矩,mm 4I i5.7638E+125.1840E+12第i段产生的挠度 1.9544E-04 1.6106E-04第i-1段产生的挠度1.4486E-04基本自振周期,sT 1代号12塔第i段操作质量,kg m i /m k 465686.3841673.29第i段集中质量距地面高度,mmh i /h k2850970070853421362398121278121.07802E+163.80341E+16基本振型参与系数0.0247540430.155430577地震影响系数曲线下降段的衰减系数γ地震影响系数曲线的阻尼调整系数η2对塔的基本振型自振周期T 1的地震影响系数α1集中质量m k 引起的基本振型水平地震力,NF 1k51927.2058129177.596721327206183404230913αmax取0.24垂直地震影响系数最大值αvmax 计算垂直地震力塔的当量质量m eq塔式容器底截面处垂直地震力任意质量i处所分配到的垂直地震力F vi158106.106948154.82082塔任意计算截面处得垂直地震力780869.2301622763.1232第2截面集中质量高度距截面处高h k -h①基本参数体型系数K 10.70.7基本风压,Pa/m2q 0450450q 0T 284.75516392代号12塔段长度,m0-5.7 5.7-13.757008000脉动增大系数ξ 1.842 1.842保温层厚度,mm δsi 100100笼式扶梯当量宽度,mm K 3400400操作平台当量宽度,mm K 412001200塔顶管线外直径d 0200200管线保温层厚度,mm δps 2018第i段计算长度,mml i 57008000第i段直径D oi 90009000风压高度变化系数f i 1.00 1.1036塔各段有效直径D ei1104011036脉动影响系数υi 0.41040.7459振型系数φzi 0.020.08264塔各计算段的风振系数(H>20m)K 2i 1.0151191361.102884239第i段计算长度,mml i 57008000水平风载荷P20122.0163533849.62446计算截面代号12塔壳有效厚度,mm δei 2018计算截面以上操作质量,kgm 0465686.3841673.29计算截面塔直径D 90009000计算截面横截面积,mm 2565486.668508938.0012计算截面断面模数,mm 312723450031145110503最大弯矩M max ,N·mm2.22472E+101.83749E+10B70461.2B 8455.21.2[σ]t159.6159.6操作时引起的轴向应力,Mpa 22.525M max 引起的轴向应力,Mpa 轴向压应力轴向拉应力30.5256439.01945经对比,明显,在任何截面地震弯矩>风弯矩允许轴向压应力m 0引起的轴向应力,Mpa是否满足条件是否满足条件七、裙座稳定校核由试验压力引起的周向应力,MPa σ69.2285由试验压力引起的轴向应力,Mpa σ128.125由质量引起的轴向应力,Mpa σ2 3.723717455由弯矩引起的轴向应力,Mpaσ35.2455591660.9R el R p0.2φ185.16825液压试验时最大组合拉应力29.64684171液压试验时最大组合压应力σ2+σ38.96927662基础环外径D ob 9300基础环内径D ib 8700基础环抗弯截面系数Z b1.8E+10基础环面积A b84823001.986781.156316181基础环无筋板时的厚度28.852628240.87561地脚螺栓的螺纹小径d 138.86928962地震载荷为控取地脚螺栓为M48,5混凝土基础上的最大应力σbmax地脚螺栓承受的最大拉应力σB取较大值八、立置液压试验时的应力校核九、基础环厚度计算十、地脚螺栓计算900090009000420042004200600006000060000600006000060000 345678 100006300294410000100007056 161414121212 35574.6519606.1717169.8912464.5512464.558795.00 33500129000000 42602683.82357.2000 5486.515001085104310431043 000000 000000 78821.1536689.9720612.0913507.5513507.559838.00 78821.1536689.9720612.0913507.5513507.559838.00 112321.1549589.9720612.09213507.5513507.559838 345678 78821.1536689.9720612.0913507.5513507.559838.00 1870026850314723794447944564722386.2384283287.9596232974.6875023416.2698466891.6882998202.619644463003630030000270561705670564.6049E+124.0266E+121.1241E-04 6.1950E-059.9849E-055.4171E-0534567878821.1536689.9720612.0913507.5513507.559838.001870026850314723794447944564722.0156E+11 1.61422E+11 1.15082E+1199836937667 1.41801E+11 1.32025E+115.15428E+177.10199E+17 6.42533E+177.37914E+17 1.4886E+18 1.77177E+180.416045920.7158059320.9083754151.202523371.7079700662.183376397147720.0019118303.588884341.7705673168.70675103923.103796758.850281473955505985125694.5648703759.4512530477.2647605977.25555715360.9727272731.519480519Tg取0.55αmax取0.240.459183488=⎪⎭⎫⎝⎛∑3H h m i i175587.9151117355.080477278.1405261056.224377147.3650166183.57703574608.3024399020.3873281665.3069204387.1663143330.94266183.577031.32644E+107.76087E+09 5.13160E+09 4.20123E+09 1.82857E+09 3.41365E+080.70.70.70.70.70.745045045045045045034567813.7-23.723.7-3030-32.94432.944-42.94442.944-52.94452.944-601000063002944100001000070561.842 1.842 1.842 1.842 1.842 1.8421001001001001001004004004004004004001200120012001200120012002002002002002002001614141212121000063002944100001000070569000900066004200420042001.3129 1.42 1.4752 1.592 1.6994 1.77110321102886286224622462240.156510251.9865780869.23010.80480.830.8360.8560.872940.880.22550.340.3990.621460.85176811.254619987 1.36606507 1.416502771 1.615507725 1.805934461 1.91579661100006300294410000100007056 57241.1904442452.922416719.6363850423.4132160169.6848846909.561876.43093E+09 3.97798E+09 2.74665E+09 2.25835E+099.35441E+08 1.65497E+081.32644E+107.76087E+09 5.13160E+09 4.20123E+09 1.82857E+09 3.41365E+086.43093E+09 3.97798E+09 2.74665E+09 2.25835E+099.35441E+08 1.65497E+08风弯矩,故该塔稳定及强度校核以地震弯矩控制345678161414121212 78821.1536689.9720612.0913507.5513507.559838.00 900090009000420042004200 452389.3344395840.6676395840.6676158336.267158336.267158336.267 1017876002890641502.1890641502.1166253080.4166253080.4166253080.41.32644E+107.76087E+09 5.13160E+09 4.20123E+09 1.82857E+09 3.41365E+084543433535355451.651.6424242159.6159.6159.6159.6159.6159.628.12532.1428571432.1428571417.517.517.52.97938895 1.917309299 1.222385593 2.127726251 1.742115137 1.0275242690.439062471-0.098756355-0.200739062-0.453958541-0.0683474280.1915366813.031488.71380 5.7616925.2701010.99871 2.0532916.0108710.63111 6.9840827.3978312.74082 3.0808138.1770938.9393436.6821640.6423826.7565918.52576校验合格(橙色的两行纵向对比)校验合格本塔无裙座,该项略合格取2.0MPa荷为控制载荷,故不需计算48,50个680335.98备注27385.45556材质弹性模量1917509.62393E+115.91526E+186554930045备注∑。
3MW 塔架强度校核一、塔架总体参数:见图纸二、机组载荷分析暴风51m/s 时,风向横向吹,风机停车工况载荷载荷计算按blade 软件提供的载荷进行。
根据报告可知:对应各段法兰接合面的最大弯矩M XY 如下:第一节底部:95382KNM 第一节顶部:77236KNM 第二节顶部:56819KNM 第三节顶部:32762KNM 第四节顶部:9780KNM第一部分:塔壁强度校核(一)受力分析1、如图剪力Q=P 风阻弯矩:Mxy 扭矩Mn压力P=机舱全重+风轮全重+分析截面上部分自重,2、工作应力:为复杂应力状态A :弯曲应力σw =Mxy/WB :剪应力:由二部分组成,一是纯剪力Q 产生的,另一个是纯扭矩Mn 产生的,最大时为二者的迭加,即τ=τ1+τ2=2Q/A 环+Mn/Wn C:压应力σ=P/A环综合:最大剪应力为τmax =τ1+τ2,发生位置为4;最大压应力为σmax =σ+σw发生位置为1。
综合上述应用第四强度理论:当量应力σdl =≤[σ]223τσ+由于以上应力最大时不同时发生在相同位置,因此计算时按不同工况及部位进行简化。
对于筒壁这里以弯矩Mxy 引起的应力σw 进行筒壁最大安全抗弯能力计算,以简化计算,计算公式:Mmax=W 弯[σ]这里:W 弯为塔筒抗弯截面模量,,D 为⎟⎠⎞⎜⎝⎛−−=⎟⎠⎞⎜⎝⎛−4343)2(132)(132D e D D D d D ππ塔筒外径,e 为塔架壁厚,[σ]为塔壁材料的安全许用应力,等于σs /n,n 为安全系数。
安全系数的选取:根据通用机械手册关于安全系数选择的要求,考虑塔筒工作的条件,如高低温、静载、周期与极端载荷交互影响,材料结构焊接,底部开门等影响和其严格的安全要求,及以上公式简化,故取安全系数n=3~4,计算中取3.5,由于塔筒材料选用Q345D,可知其σs=500MPa=500(N/mm2),[σ]=143(N/mm2)进行计算。
塔设备机械强度校核(一)已知条件:(1)塔体直径i D =800mm ,塔高H=29.475m 。
(2)设计压力p=2.3Mpa 。
(3)设计温度t=19.25O C ,(4)介质为有机烃类。
(5)腐蚀裕量2C =4mm 。
(6)安装在济南地区(为简化计算,不考虑地震影响)。
(二)设计要求(1)确定塔体和封头的厚度。
(2)确定裙座以及地脚螺栓尺寸。
(三)设计方法步骤A 材料选择设计压力p=2.3Mpa,属于中压分离设备,三类容器,介质腐蚀性不提特殊要求,设计温度19.25O C ,考虑选取Q235-C 作为塔体材料。
B 筒体、封头壁厚确定先按内压容器设计厚度,然后按自重、液重等引起的正应力及风载荷引起的弯曲应力进行强度和稳定性验算。
a 筒体厚度计算按强度条件,筒体所需厚度d δ=[]22it pD C pσ+Φ-= 2.3800420.85125 2.3?+??-=12.75 mm 式中[]t t σ——Q235-C 在19.25O C 时的许用应力。
查《化工设备机械基础》为125MpaΦ——塔体焊缝为双面对接焊,局部无损检测,Φ=0.85。
2C ——腐蚀裕量,取值4mm 。
按刚度要求,筒体所需最小厚度min δ=22800 1.610001000i D mm ?==。
且min δ不小于3mm 。
故按刚度条件,筒体厚度仅需3mm 。
考虑到此塔较高,风载荷较大,而塔的内径不太大,故应适当增加厚度,现假设塔体厚度n δ=20mm ,则假设的塔体有效厚度e δ=12n C C δ--=20-4.8=15.2mm式中1C ——钢板厚度负偏差,估计筒体厚度在8~25mm 范围内,查《化工设备机械基础》的1C =0.8mm 。
b 封头壁厚计算采用标准椭圆形封头,则[]2 2.3800421250.850.5 2.320.5id t pD C p δσ?=+=+??-?Φ- =12.71mm 。
为便于焊接,取封头与筒体等厚,即n δ=20mm 。
塔器强度校核软件开发说明书学校:兰州理工大学学院:石油化工学院开发人:郑运虎指导教师:梁瑞(教授)姜峰(副教授)二零一四年六月十日1. 开发目的为便于大型塔器顺利安装、降低安装成本、提高作业效率,根据GB4710与GB150等相关标准,结合材料在高温650℃热处理条件的强度要求开发出塔器强度校核软件。
2. 开发特点(1)软件开发者在开发软件过程中首先应该考虑的是计算准确、安全并且与计算结果极力靠拢,保证真实性。
(2)其二,软件的便利出了能尽快给出可信的结果,另外要求界面尽量友好、美观,便于操作,尽量体现人性化等操作特点。
(3)为方便用户对输出结果进行查看、打印、另存以及其他粘贴、复制等操作,将VB6. 0与EXCEL等办公软件结合起来,实现程序与EXCEL的无缝连接,并将强度校核报表以E xcel的形式输出。
3、软件设计3.1 功能模块设计对系统功能分析中的各项功能进行集中、分块,按照结构化程序设计的要求,得到系统功能模块图如下:图1 软件系统功能模块图3.2 计算模块计算功能模块是软件的关键部分,为具体说明计算模块的流程,下面对计算功能模块以流程图的形式进行说明。
图2 计算模块流程图4、界面设计好的界面、人性化的操作方式给用户会带来愉快的感觉!下面就该软件的设计的界面以图片格式进行具体列举:图3 登录界面图4 启动界面图5 参数数据界面图6 计算提示界面图7 计算完成提示界面图8 提取结果参数输入界面图9 结果提取提示界面图10 结果提取完成界面图11 结果显示界面图10 其他相关提示界面图11 计算完成自动弹出的结果存储路径界面5、实例应用某长有一丙烯塔,总高65850mm,组装时分三段组装,各段长度从下至上依次为234 40m,21900mm和20510mm,内径为5200mm,材料为Q345R.塔器裙座高度4800mm,第二焊接截面距塔器裙座焊接截面的高度为3200。
裙座名义厚度为30mm,第一焊接截面与第二焊接截面之间材料的名义厚度为30mm,其他各部位壳体的名义厚度均为44mm,焊接系数0.85,校核过程按设防烈度8度,场地土类别为II,地面粗糙粗为B,一阶振型系数0. 01,校核时分别将塔器分为3段校核和16段校核。