ZDR 电阻真空计
- 格式:pdf
- 大小:379.20 KB
- 文档页数:1
◆ZDZ-52T/1B2型电阻真空计◆ZDZ-52T/1B3型电阻真空计技术参数:●测量路数:1路●规管型号:ZJ-52T电阻规●测量范围:1.0×105Pa~ 1.0×10-1Pa●控制范围:2.5×103Pa~ 5.0×10-1Pa●控制路数:2路●控制精度:±1%●控制方式:继电器触点通断、负载能力AC220V/3A DC28V/10A(无感负载)点动或区域控制/带掉电记忆●显示方式:五位LED数字显示,采用科学计数法,例:1.2E-1表示为1.2×10-1Pa ●模拟输出:(0~5)V;(4~20)mA●通讯接口: RS-485●采样时间: 1S●电源:AC 220V±10% 50Hz●功耗:30W●重量:约3.5Kg●机箱尺寸:ZDZ-52T/1B2型 88×280×260 mm (高×宽×深)ZDZ-52T/1B3型 96×96×160mm (高×宽×深)●使用环境温度:0℃~45℃湿度:≦85%◆ZDZ-51A1型双电阻真空计技术参数:●测量路数:2路(电阻规2路)●规管型号:ZJ-52T电阻规●测量范围:1.0×105Pa~ 1.0×10-1Pa●控制范围:2.5×103Pa~ 5.0×10-1Pa●控制路数:4路●控制精度:±1%●控制方式:继电器触点通断、负载能力AC220V/3A DC28V/10A(无感负载)点动或区域控制/带掉电记忆●显示方式:五位LED数字显示,采用科学计数法例:1.2E-1表示为1.2×10-1Pa●通讯接口:RS-232/RS-485●采样时间: 1S●电源: AC 220V±10% 50Hz●功耗:30W●重量:约6Kg●机箱尺寸:88×480×280 mm (高×宽×深)●使用环境温度:0℃~45℃湿度:≦85%◆ZDO-54/1B2型定流式热偶真空计◆ZDO-54/1B3型定流式热偶真空计技术参数:●测量路数:1路●规管型号:ZJ-53B/玻璃、ZJ-54D/金属直插(选配)●测量范围:1.0×103Pa~ 1.0×10-1Pa●控制范围:3.0×102Pa~ 1.0×100Pa●控制路数:2路●控制精度:±1%●控制方式:继电器触点通断、负载能力AC220V/3A DC28V/10A(无感负载)点动或区域控制/带掉电记忆●显示方式:五位LED数字显示,采用科学计数法例:1.2E-1表示为1.2×10-1Pa●通讯接口:RS-485●采样时间: 1S●电源: AC 220V±10% 50Hz●功耗:小于20W●重量:约3Kg●机箱尺寸:ZDO-54/1B2型 88×280×260 mm (高×宽×深)ZDO-54/1B3型 96×96×120 mm (高×宽×深)●使用环境温度:0℃~45℃湿度:≦85%◆ZDF-11A2复合真空计技术参数:●测量路数:2路(电阻规、电离规各1路)●规管型号:ZJ-52T电阻规 ZJ-27电离规●测量范围:1.0×105Pa~ 1.0×10-5Pa●控制范围:2.5×103Pa~ 5.0×10-5Pa●控制路数:4路●控制精度:±1%●控制方式:继电器触点通断、负载能力AC220V/3A DC28V/10A(无感负载)点动或区域控制/带掉电记忆●显示方式:五位LED数字显示,采用科学计数法例:1.2E-1表示为1.2×10-1Pa●通讯接口:MODBUS/RTU(标配,自定义协议,地址可以设定,带CRC校验) ●电离规外控:PLC●采样时间: 1S●电源: AC 220V±10% 50Hz●功耗:50W●重量:约6Kg●机箱尺寸:88×480×280 mm (高×宽×深)●使用环境温度:0℃~45℃湿度:≦85%◆ZDF-91B2复合真空计技术参数:●测量路数:3路(电阻规2路、电离规1路)●规管型号:ZJ-52T电阻规2个 ZJ-27电离规1个●测量范围:独立电阻单元1.0×105Pa~ 1.0×10-1Pa复合单元1.0×105Pa~ 1.0×10-5Pa●控制范围:电阻单元 2.5×103Pa~ 5.0×10-1Pa复合单元 2.5×103Pa~ 5.0×10-5Pa●控制路数:6路●控制精度:±1%●控制方式:继电器触点通断、负载能力AC220V/3A DC28V/10A(无感负载)点动或区域控制/带掉电记忆●显示方式:五位LED数字显示,采用科学计数法,例:1.2E-1表示为1.2×10-1Pa ●模拟输出:(0~5)V,(4~20)mA [注:只有独立电阻单元有模拟输出]●通讯接口:MODBUS/RTU(标配,自定义协议,地址可以设定,带CRC校验)●电离规外控:PLC●采样时间: 1S●电源: AC 220V±10% 50Hz●功耗:80W●重量:约7Kg●机箱尺寸:88×480×280 mm (高×宽×深)●使用环境温度:0℃~45℃湿度:≦85%◆ZDR-27/1C2型热阴极电离真空计技术参数:●测量路数:1路(电离规1路)●规管型号:ZJ-27电离规●测量范围:1.0×10-1Pa~ 1.0×10-5 Pa●控制范围:1.0 Pa~ 5.0×10-5Pa●控制路数:无●控制精度:±1%●显示方式:五位LED数字显示,采用科学计数法,例:1.2E-1表示为1.2×10-1Pa ●电离规外控:PLC●采样时间: 1S●电源: AC 220V±10% 50Hz●功耗:30W●重量:约3Kg●机箱尺寸:280×88×260 mm (宽×高×深)●使用环境温度:0℃~45℃湿度:≦85%◆ZDR-121/A1型超高热阴极电离真空计技术参数:●测量范围: 1.0×10-1Pa~6.0×10-8Pa●配备规管: ZJ-12电离规●测量路数: 1路●显示方式:五位LED数码显示●通讯接口: MODBUS/RTU(选配,需提前说明)●采样时间: 1S●电源: AC 220V±10% 50Hz●功耗: 22W●重量:约5Kg●机箱尺寸:89×480×200 mm (高×宽×深)●使用环境温度:0℃~45℃湿度:≦85%。
电阻真空计检定规程嘿,朋友们!今天咱来聊聊电阻真空计检定规程这档子事儿。
电阻真空计啊,就像是一个特别会“看”压力的小机灵鬼。
它能告诉我们真空环境到底是啥情况。
那这检定规程呢,就好比是给这个小机灵鬼立的规矩,告诉它该怎么好好表现,怎么准确地给我们汇报情况。
你想啊,要是没有这些规矩,那它还不得乱了套呀!它要是随随便便给出个不准确的数值,那我们可就抓瞎啦!就好比你要去一个地方,没有地图给你指引方向,那你不得晕头转向呀!这检定规程可细致啦!从怎么安装电阻真空计,到怎么去检测它,每一步都规定得明明白白。
这就像是我们做饭,得先准备好食材,再按照步骤一步一步来,最后才能做出美味的菜肴。
比如说,它会要求我们用特定的标准器具去校准电阻真空计,这就好像是给它找了个好老师,教它怎么变得更厉害。
而且还规定了检测的环境条件呢,温度啊、湿度啊都得合适,不然它也会闹脾气,给出不准确的结果哦。
我们在实际操作的时候可得认真对待这些规程呀!不能马马虎虎的。
就像你对待自己最喜欢的宝贝一样,小心翼翼地呵护着。
要是不按照规程来,那可不行哦,就好像你不遵守交通规则,那肯定得出乱子呀!每次进行检定的时候,我都感觉自己像是个侦探,在仔细寻找每一个可能影响结果的小细节。
这可不是开玩笑的,一个小小的疏忽都可能让整个检定结果变得不准确。
咱再想想,如果没有严格的电阻真空计检定规程,那会怎么样呢?工厂里生产的产品质量可能就没法保证啦,科研实验的数据也可能不准确呀!那可真是不得了啦!所以呀,大家可别小瞧了这电阻真空计检定规程哦!它虽然看起来不起眼,但作用可大着呢!我们一定要好好遵守它,让我们的真空测量工作顺顺利利的,为我们的生产和科研提供准确可靠的数据。
这不就是我们一直追求的嘛!怎么样,现在知道它的重要性了吧!原创不易,请尊重原创,谢谢!。
产品名称: 电阻真空计产品型号: ZDZ-52T使用说明书Operation Panel目录1.简介--------------------------------------------------11.1 仪器简介----------------------------------------11.2 包装内容----------------------------------------12. 主要技术参数-----------------------------------------13. 仪器安装---------------------------------------------23.1仪器安装尺寸-------------------------------------------23.2仪器后面板图示及接线说明-----------------------------24. 仪器操作指南------------------------------------------------25. 故障诊断---------------------------------------------36. 注意事项 -------------------------------------- --41.1仪器简介ZDZ-52T型电阻真空计,可测量1路规管信号,控制2路继电器触点输出及0~5V模拟量输出。
在测量范围内,可自由设定点控或区域控制。
适合用于粗、低真空的测控。
ZDZ-52T型电阻真空计采用高档微处理器作主机,压缩外围部件,以提高可靠性。
本机电源采用高档模块电源,硬件采用模块化结构设计及EMI抑制、WATCHDOG电路,软件采用冗余、陷阱、数字滤波等抗干扰技术,进一步提高了仪器的抗干扰能力及整机性能,使仪器具有很高的可靠性,可在恶劣的工业环境下使用。
1.2 包装内容◆ZDZ-52电阻真空计一台◆ZDZ-52使用手册一本◆ZJ-52T电阻规管一支◆5芯电缆线(5M) 一根◆电源线(1.5M) 一根2.主要技术参数1测量路数 1路2 测量范围 1.0×105—1.0×10-1 (Pa)4 配接规管 ZJ-52T/KF165 测量精度 ±30%6 零点漂移 ±1%7 控制范围 1.0×105—1.0×10-1 (Pa)8 控制方式 2路点控或区域控制(本机无)9 控制精度 ±1%10 控制时间 < 1S11 输出容量 3A/220VAC无感负载12 模拟输出 0~5V13 使用电源 AC 220V/50Hz ±10%14 环境温度 -10℃--45℃15 环境湿度 < 85%(25℃)16 额定功耗 10W17 仪器净重 约1.5Kg3.仪器安装3.1仪器安装尺寸:单位(mm)A.外形尺寸:96X96X190(宽X高X深)B.面板尺寸:96X96C.开孔尺寸: 92X923.2 后面板接线说明:A:电源插座:接3芯电源线B:电阻规插座(5PIN):电缆线说明:仪器端←--------→规管端 后面板接线端口 (1,2,3,4) 对应 (1,2,3,4)选配扩展功能:C: 模拟输出接口(DB-9),可输出0-5/10V/10mV 或 0/4-10/20mA等的真空度模拟输出量。
书山有路勤为径,学海无涯苦作舟电阻真空计测量线路的三种模式实用的电阻真空计测量线路常采用惠氏电桥或文氏电桥。
根据测量热丝电阻变化的方法不同,可分为三种模式:(1)定电压法:保持电桥两端电压不变,观察失平衡电流与压力的关系。
(2)定电流法:保持热丝电流(或电桥电流)不变,观察失平衡电压与压力的关系。
(3)定电阻法(即定温度法):在任何压力下都用改变电桥电压的方法,保持电桥于平衡状态。
电桥电压与压力的关系即为校准曲线。
在此方法中,热丝电阻及其温度基本为定值,具有热辐射及边杆导热均为恒定的优点。
在以上三种模式中,常用的是定电压法和定温度法。
定压型电阻真空计的测量线路原理如当规管内的压力变化时,由于被气体传导走的热量不同于开始时的平衡状态,因而热丝的温度发生变化,引起其电阻值改变,电桥失去平衡。
压力的变化由指示仪表CB 读出,CB 指示的电流值与压力的关系,通过校准曲线给出。
规管热丝用半径r1 =0.01mm 的钨丝绕制成圆柱螺旋形,其室温下电阻Rw =200Ω。
由于各种气体的导热系数不同,因此,对不同种类气体的校准曲线是不同的。
定压型测量线路的优点是结构简单;不足之处是电桥电压是固定的,故在压力高时由于气体导热快,热丝温度降低,导致规管灵敏度下降,测量高于100Pa 的压力就甚为困难。
实际上,定电压型测量线路的测量上限并未达到规管的理论值(即λ≈r1 所对应的压力)。
真空技术网(chvacuum/)认为为了保证高压力时有较高的灵敏度,必须使热丝此时处于足够高的温度,然而在压力变低时它的温度将增高到有可能使热丝氧化或烧毁的程度。
大气压氩气环境下体积介质阻挡放电光谱特性宋飞龙;金迪;贾敏;宋志杰【摘要】通过介质阻挡放电产生的等离子体可与燃料中的烃类分子发生碰撞裂解反应,将燃料分子裂解生成更容易起爆的氢气和小分子烃类,能有效改善液体燃料连续旋转爆震发动机的起爆性能.该研究在真空仓中开展体积介质阻挡放电的丝状放电光谱测试,分析了大气压氩气环境下体积介质阻挡放电的电子激发温度和电子密度随加载电压的变化规律.丝状放电的电子激发温度通过波尔兹曼斜率法计算,电子密度采用斯塔克展宽法计算.发现发射谱线均由氩原子4 p—4s能级跃迁产生;各谱线强度随加载电压的提高均呈上升趋势,且与电压基本呈线性关系;对于大气压丝状放电,加载电压对电子激发温度和电子密度没有明显影响作用,加载电压12.5~14.5 kV范围内,电子激发温度稳定在3400 K附近,电子密度在1025 m-3量级.%Plasma produced through dielectric barrier discharge can react with hydrocarbon molecules in the fuel by collision cracking reaction ,causing fuel molecules to be decomposed into hydrogen and small molecule hydrocarbons that are more prone to detonate ,which will improve the ignition properties of the continuous rotating detonation engine with liquid fuel.In this pa-per ,the spectral test of volume dielectric barrier discharge (DBD) was carried out in vacuum chamber in order to analyze how the electron excitation temperature and electron density of volume DBD change with the applied voltage under atmospheric pressure argon.In addition ,the electron excitation temperature of filamentous discharge was calculated by the Boltzmann slope method , and the electron density was calculated by Stark broadening method.It was found that all of theemission lines arose from elec-tronically excited argon atoms 4 p-4s transitions.The intensities of the lines increased with the increase of the applied voltage and had a linear relationship with the voltage basically.For the atmospheric filamentous discharge ,the load voltage has no obvious effect on the electron excitation temperature and the electron density.When the applied voltage is in the range of 12.5~14.5 kV ,the electron excitation temperature is stabilized around 3400 K ,and the electron density is on the order of 1025 m -3.【期刊名称】《光谱学与光谱分析》【年(卷),期】2018(038)006【总页数】5页(P1675-1679)【关键词】丝状放电;发射光谱;电子激发温度;电子密度【作者】宋飞龙;金迪;贾敏;宋志杰【作者单位】空军工程大学等离子体动力学重点实验室 ,陕西西安 710038;空军工程大学等离子体动力学重点实验室 ,陕西西安 710038;空军工程大学等离子体动力学重点实验室 ,陕西西安 710038;空军工程大学等离子体动力学重点实验室 ,陕西西安 710038【正文语种】中文【中图分类】O536引言连续旋转爆震发动机(CRDE)对于提高航空推进器性能有着潜在优势[1-2]。
电阻真空计校准
电阻真空计是一种广泛应用于真空技术领域的仪器,主要用于测量低压下的气体压力。
由于其高精度和稳定性,被广泛应用于真空设备的制造和维护中。
然而,在使用电阻真空计时,其精度和正确性需要得到保证,因此需要进行定期的校准。
下面将对电阻真空计校准进行详细介绍。
需要了解电阻真空计的工作原理。
电阻真空计是基于电阻的变化原理进行测量的。
当电阻器中的气体分子数量变化时,其电阻值也会相应地发生变化,从而实现对气体压力的测量。
因此,电阻真空计的校准需要考虑气体的种类和压力范围。
电阻真空计的校准需要使用专业的校准仪器。
一般来说,校准仪器会在一定的气体压力范围内提供标准的电阻值,从而可以对电阻真空计进行校准。
在校准过程中,需要保证校准仪器和电阻真空计的接口紧密连接,并且需要保证气体的流通畅通,以保证校准结果的准确性。
电阻真空计的校准还需要考虑其他因素的影响。
例如,校准环境的温度和湿度会影响校准结果,因此需要进行恰当的调整。
此外,校准前需要对电阻真空计进行清洁和维护,以保证其正常工作。
电阻真空计的校准需要定期进行。
一般来说,校准的频率取决于使用频率和环境条件等因素。
在实际应用中,需要根据具体情况进行
调整。
另外,需要记录每次校准的结果和时间,并及时处理校准结果异常的情况。
电阻真空计的校准是保证其正常工作和准确测量的重要步骤。
在进行校准时,需要使用专业的校准仪器,并且需要考虑多种因素的影响。
通过定期的校准,可以保证电阻真空计的精度和稳定性,从而为真空技术领域的研究和应用提供可靠的支持。
电阻真空规
电阻真空规是一种用于测量真空度的仪器。
它利用电阻的变化来测量真空度。
在真空室内,电极之间的电阻会随着气体分子的减少而增加。
通过测量电阻的变化,可以确定真空度的大小。
电阻真空规的工作原理是利用真空室内的金属电阻片的电阻值随真空度的变化而变化,将电阻值转化为电压信号,经过放大、处理、显示等过程,最终得到真空度的数值。
电阻真空规具有灵敏度高、可靠性好、测量范围广等优点。
它广泛应用于真空技术、半导体制造、物理实验等领域。
- 1 -。
真空计原理及测量范围
真空计是一种用于测量真空度的仪器,根据不同的原理可以分为多种类型,包括气体扩散法真空计、热导法真空计、冷阴极离子化真空计等。
下面将分别介绍这几种常见的真空计的原理及测量范围。
1.气体扩散法真空计
气体扩散法真空计是通过测量气体扩散速率来间接得到真空度的。
工作原理是将样品或测量环境中的气体进入真空计中,利用气体在真空中自由扩散的特性,通过测量扩散流量来计算真空度。
该方法适用于较高真空度的测量范围,通常在10^-1至10^-7帕之间。
2.热导法真空计
热导法真空计主要基于热导率与气体密度之间的关系来测量真空度。
它包含一个加热丝和一个测量电阻,当加热丝加热时,传热受到气体分子碰撞的影响,从而导致电阻的变化,根据电阻的变化可以计算出气体的密度。
热导法真空计适用于1至10^5帕的测量范围。
3.冷阴极离子化真空计
冷阴极离子化真空计主要通过测量空间中的电离电流来间接测量真空度。
该方法通过在真空计中放置一个冷阴极,当真空中的气体与冷阴极发生碰撞时,会产生电子,然后利用电子与气体分子碰撞产生离子,通过测量电离电流的大小来计算真空度。
冷阴极离子化真空计适用于10^-4至10^-2帕的测量范围。
以上所述的是一些常见的真空计的原理及测量范围,不同的真空计适用于不同的测量条件和要求。
在实际应用中,还需要根据具体的测量需求选择合适的真空计,以获得准确可靠的测量结果。
电阻真空计的故障诊断及检修方法电阻真空计是一种常用的真空度测量仪器。
它利用电流通过真空中的电阻,根据欧姆定律计算出真空计的阻值,从而推断出真空度。
然而,由于使用环境和使用方法等原因,电阻真空计也会出现故障。
本文将介绍电阻真空计常见的故障及其诊断和检修方法。
首先,需要了解电阻真空计的基本结构。
电阻真空计一般由电阻丝、电源、电流表和压强表等部分组成。
电阻丝是电阻真空计的核心部分,它的电阻值与真空度成正比。
当真空度变化时,电流经过电阻丝的变化程度直接反映了真空度的变化。
接下来,我们将介绍电阻真空计可能出现的故障症状以及对应的故障诊断和检修方法。
1.电阻丝破裂:电阻丝是电阻真空计中最易损坏的部分,常见故障是电阻丝破裂。
这种情况下,电流表无法读数,并且压强表显示为最大值。
电阻丝破裂通常是由于长时间高电流通过或负载过重引起的。
解决方法是更换电阻丝。
2.电压异常:当电源电压异常时,电阻真空计无法正常工作。
可以用电压表检查电源电压是否正常,如果不正常则应调整或更换电源。
3.电流异常:当电流表的读数异常时,可能是电流表损坏或接触不良引起的。
可以用万用表进行测量,如果电流表的读数与万用表测量的值相差较大,则需要更换电流表。
4.压强异常:当压强表的读数异常时,是因为电阻真空计的输出信号异常引起的。
需要检查电阻真空计的输出信号是否正常,如果不正常则可能是电源、电流表或压强表等部分引起的。
可以逐个检查这些部分的工作状态,发现问题后进行修理或更换。
5.清洁不彻底:在使用过程中,电阻真空计表面可能会积累灰尘或杂质,导致其读数不准确。
因此,定期清洗电阻真空计,保持其表面的清洁非常重要。
可以使用无粉尘布擦拭电阻真空计的外表面,并注意避免使用有擦拭剂或腐蚀性液体。
总结起来,电阻真空计的故障诊断和检修方法包括更换破损的电阻丝、调整或更换电源、电流表和压强表,以及定期清洗仪器表面。
应该注意的是,对于更加复杂的故障,最好由专业维修人员来进行检查和修理。
ZDR—II—LED微机型数显电阻真空计使用说明书OPERATION.INSTRUCTION一、简介ZDR—II—LED型数显双路电阻真空计,是目前国内的新型真空计测量仪器。
它采用微机控制、数字显示,具有测量精度高,控制准确方便,显示直观等特点。
本仪器采用当今世界流行的薄膜面板及能触摸按钮,造型美观大方。
二、适用范围ZDR—II—LED型数显双路电阻真空计配ZJ-52T电阻规管,其测量范围为1*105~1*10-1Pa,适用于要求测量范围宽,反映灵敏的粗、低真空的双路测量,并带有双路定值控制功能。
三、技术指标1、ZJ-52T规管电阻值:85Ω2、真空度测量范围:1*105~1*10-1Pa3、定值控制设定范围:1*105~1*10-1Pa4、定值控制负数:AC220V/3A(或DC28V/10A)5、放大器满度误差:≤4%±1个字6、工作电源:220V±10% 50HZ±5%7、功耗:约30W8、使用环境温度:0~45℃9、空气相对湿度:<85%10、仪器外型规格:480*88*280或240*88*320mm11、重量:3KG四、工作原理电阻计的工作原理是基于在低压强时,利用气体分子的热传导,在高压时,利用气体分子的对流传热特性,使得电阻规的电阻随所测系统的压强变化而变化。
电阻规的电阻与压强的变化是一种非线性关系,鉴次本机采用微机对此非线性进行误差修正,从而提高了测量精度。
由压强变化所引起的电阻规电阻的变化,由测量桥路输出电压信号,由放大器放大,经A/D转换换入微机进行非线性处理过算,最后送显示器显示。
其工作原理框图如下五、使用方法:1、将玻璃电阻规或金属电阻规开封与系统妥善密封连接,将仪器电缆线与规管连接。
2、接通仪器电源,数秒后显示“规1”测量值(左边),“规2”真空测量值(右边)。
真空度显示前两位为系数,第三位是底数10,用数字符号E来表示,最后位为指数。
如显示2.8E2时,其真空度P=2.8*102Pa=280Pa3、零点、满度校准由于电阻规制造时材料、工艺、装配等方面的因素,不同电阻规的性能有差异。
电阻真空计的故障诊断及检修方法断路器可能出现的故障有很多,原因也很多,我总结了集中经常会碰见的原因,你先看一下:1、常见的真空断路器不正常运行状态断路器拒合、拒分表现为在断路器得到合闸(分闸)命令后,合闸(分闸)电磁铁动作,铁心顶杆将合闸(分闸)掣子顶开,合闸(分闸)弹簧释放能量,带动断路器合闸(分闸),但断路器灭弧室不能合闸(分闸)。
断路器误分表现为断路器在正常运行状态,在不明原因情况下动作跳闸。
断路器机构储能后,储能电机不停表现为断路器在合闸后,操动机构储能电机开始工作,但弹簧能量储满后,电机仍在不停运转。
断路器直流电阻增大表现为断路器在运行一定时间后,灭弧室触头的接触电阻不断增大。
断路器合闸弹跳时间增大表现为断路器在运行一定时间后,合闸弹跳时间不断增大。
断路器中间箱CT表面对支架放电表现为断路器在运行过程中,电流互感器表面对中间箱支架放电。
断路器灭弧室不能断开表现为断路器在进行分闸操作后,断路器不能断开或非全相断开。
2、故障原因分析断路器拒分、拒合操动机构发生拒动现象时,一般先分析拒动原因,是二次回路故障还是机械部分故障,然后进行处理。
在检查二次回路正常后,发现操动机构主拐臂连接的万向轴头间隙过大,虽然操动机构正常动作,但不能带动断路器分合闸联杆动作,导致断路器不能正常分合闸。
断路器误分断路器在正常运行状态下,在没有外施操作电源及机械分闸动作时,断路器不能分闸。
在确认没有进行误操作的情况下,检查二次回路及操动机构。
发现操动机构箱内辅助开关接点有短路现象,分闸电源通过短路点与分闸线圈接通,造成误分闸。
原因是断路器机构箱顶部漏雨,雨水沿着输出拐臂向下流,正好落在机构辅助开关上,造成接点短路。
断路器机构储能后,储能电机不停断路器在合闸后,操动机构储能电机开始工作,弹簧能量储满后,发出弹簧已储能信号。
储能回路中串有断路器一对常开辅助接点和一对行程开关常闭接点,断路器合闸后,辅助开关的常开接点接通,储能电机开始工作,弹簧储满能量后,机构摇臂将行程开关常闭接点打开,储能回路断电,储能电机停止工作。
电阻真空计测量原理
电阻真空计是一种常用的真空度测量仪器,其测量原理基于电阻的
变化与气体压力的关系。
本文将从原理、结构和使用等方面进行介绍。
一、原理
电阻真空计的测量原理基于电阻的变化与气体压力的关系。
当真空度
提高时,气体分子的数量减少,电阻器内的气体分子碰撞减少,电阻
器的电阻值随之增加。
因此,通过测量电阻器的电阻值变化,可以推
算出真空度的大小。
二、结构
电阻真空计主要由电阻器、电源、指示器和真空室等组成。
其中,电
阻器是测量真空度的核心部件,其内部包含一定量的气体,通过电源
加热电阻器,使气体分子加速运动,从而提高电阻器的电阻值。
指示
器则用于显示电阻器的电阻值,从而推算出真空度的大小。
真空室则
用于保持测量环境的真空度。
三、使用
电阻真空计的使用需要注意以下几点:
1. 在使用前需要对电阻真空计进行校准,以确保测量结果的准确性。
2. 在使用过程中,需要保持真空室的密封性,避免气体泄漏影响测量
结果。
3. 在测量过程中,需要控制加热电阻器的温度,避免过高的温度损坏
电阻器。
4. 在使用后,需要对电阻真空计进行清洁和保养,以延长其使用寿命。
总之,电阻真空计是一种常用的真空度测量仪器,其测量原理基于电
阻的变化与气体压力的关系。
在使用过程中,需要注意保持真空室的
密封性,控制加热电阻器的温度,以及对电阻真空计进行清洁和保养
等方面。