LANDesk产品手册2010上海联阳
- 格式:doc
- 大小:3.15 MB
- 文档页数:42
CARD DATA STRINGTRACK 11. SS is the start sentinel ( % ).2. ES is the end sentinel ( ? ).3. Card Id up to 76 alphanumeric data characters.TRACK 21. SS is the start sentinel ( ; ).2. ES is the end sentinel ( ? ).3. Card Id up to 37 numeric data characters.TRACK 31. SS is the start sentinel ( + ).2. ES is the end sentinel ( ? ).3. Card Id up to 104 numeric data characters.Note: Track 3 can read both ISO TK3 format and ISO TK1 format.iBUTTON DATA STRING:OptionSTEP 1 : Run MSR ConfigureSTEP 2 : Choose PS/2 or COM port and press “Scan” ,connect theMSR220/250 reader.START MSRCONFIGURE SOFTWAREApply the bundled disk no. 5296 to begin with the demo software.STEP3 : Click “Read” ,scan the MSR220/250 reader parameter.General :Interface : MSR Interface is being detected. Buzzer : Choose buzzer enable or disable.Feed Back : Set MSR output data ,waiting for feedback from the terminal. Show `Error 'message if no reaction from MSRRS232(UART): Setting MSR communication parameter ,when RS232 and serial USB enable .Package :Setting MSR & iButton data output package .MSR Data Package :iButton Data Package :Data Format :Keyboard : Setting MSR language ,when keybpard enable .FE1 : Package ending character.FS :Package leading character.FE0 : Package ending character.check : Bit check up.iButton: Set iButton data format .Data format :Present ID format : Set present iButton output ID format .Release ID format : Set release iButton output ID format .Family Code : Terms for iButton series.PS : iButton present prompt character.RS : iButton Release prompt character.SS : Start Sentinel ES : End SentinelFF : To set up direct side cardswipe prompt character.RR : To set up reverse side cardswipe prompt character.Swipe Card Direction : To set up prompt character for direct/reverse side card swipe prompt character.Decode Standard : To decode magstripe format.Mark Code :Leading character to set up output data.Decode Mode : To decode magstripe data.Magnetic Card: Set MSR data format and data output parameter .SS : Start Sentinel ES : End SentinelTK ES0 :Ending prompt character .TK ES1 : Ending prompt character .Track Output Order : To set up track data in turn.Track Length : To set up track data length.Head Compatible : To set up the decoding work for IBM or JIS2 data output at one time only.MSR package :JIS2 :JIS2 data format.AAMVA :AAMVA data format .IBM :IBM data format .7Bit : 7 Bits Per Character data.ABA :5 Bits Per Character data .STEP4 : Click “Write” ,write the parameter to MSR220/250 reader .Click “Open or Save” open or save your choose parameter to file. PS.Same as to when MSR220/250 reader is in RS232 interface mode,Keyboard function will be in disable mode .When MSR220/250 reader is in Keyboard function, RS232 interface will be in disable mode.STEP5 : Click “Test Mode” can test the MSR220/250 .STEP6 : Click “Default” can reset MSR220/250 parameter.。
1008146 Rev. A©2010 Spyker Spreaders/A Brinly-Hardy Co.Model P30/S30 SeriesSpyker SpreadersContact Us at 800.972.6130This manual contains information for the safetyof persons and property. Read it carefully before assembly and operation of the equipment!IMPORTANT Operator's Manual1008146 Rev. A2Spinner/Axle Explosion1008146 Rev. A3No.Part Number Qty Description105-94-00646Nylon Washer2SS-91-0004131/4-20 Nylon Locknut,SS31007745-011Towtube, Polished1007744-101Towtube, Painted 41007746-011Control Handle, Polished 1007740-101Control Handle, Painted 510078282Handle Knob61008023-011Frame, Polished1008026-101Frame, Painted705-90-0080111/4-20 x 1-3/4" HexBolt SS8SS-94-00071Hopper Bottom Bearing 905-44-22101Accuway Screw Assembly 1005-71-22051Hopper Bottom Plate 1105-94-00422Rate Gate/AccuwayGuide1205-94-00431Accuway Diffuser1399-10-020551/4-20 x 1/2" Bolt, SS 1405-94-00681Rate Gate1505-94-00691Dial Mount16SS-94-00061Plastic Dial1705-94-00781Pine Tree Clip1805-24-11021Rate Gate Link, Polished 1910081281Hopper, 12520 Series 10081321Hopper, 17520 Series 2005-93-00751Spyker Accuway Label 2110080671Spyker Decal 2210081651Flow Control Decal23SS-90-00021Roll Pin 1/8 x 7/8"24SS-92-00022Felt Washer2505-125-00701Spinner Shaft26SS-90-00011Roll Pin 1/8 x 3/4" 2705-90-009325/8" Gearbox Bushing 2805-90-009423/8" Spinner ShaftBushing2905-90-009613/16 x 1" Dowel Pin, SS 3005-94-00331Bevel Gear3105-94-00341Pinion Gear No.Part Number Qty Description3205-288-10271Nylon Pin Retainer3305-90-00978#10-24 x 5/8" FlangeHead Bolt, SS3405-91-00088#10-24 Nylon Locknut,SS3505-94-00371Gear Box Cover Front 3605-94-00381Gear Box Cover Rear 3705-98-01111Grease Zerk 3810081251Axle3905-95-0016-JD2Wheel40SS-94-0012-11Spinner4110081041Screen42SS-96-00031Agitator Wire4305-179-0040 2Tow Bar Brace, SS 1000566-102Tow Bar Brace, Painted 4405-90-003811/4-20 x 2" Hex Bolt, SS 4505-90-006513/16 x 1-3/4" Clevis Pin 4605-90-00891Hairpin Cotter, Large 4705-92-00041Wheel Washer, SS 481001693-012Hitch Plate, Polished 1001147-102Hitch Plate, Painted49SS-90-00061Clevis Pin5005-92-00141Nylon Spacer5105-90-00401Rue Ring Locking Pin 521007739-011Control Bracket, Polished 1007709-101Control Bracket, Painted 5310077421Control Link54SS-90-001111/4-20 x 1-1/4" HexBolt, SS5545M0909SS10Washer, SS5645M2121P45/8" Flat Washer57B-6978-012Spacer58D-146P1Hairpin Cotter, Small59F-2832Axle Bearing60F-5751Special Thick Washer 6110081461Operation Manual1008146 Rev. A41. Install spinner to spinner shaft. Press down onspinner until it snaps into place on the roll pin,Figure 1.2. Install axle/transmission assembly into frameas shown, Figure 1. IMPORTANT! Note theorientation of the axle/transmission assembly is critical. See the hole locations in Figure 1. One side has hole near the end of the axle, the other next to the frame.3. Slide the axle bearings over the axle andinto place in the frame, Figure 1.4. Install a 5/8" metal washer, axle spacer, and asecond 5/8" metal washer onto axle, Figure 2.Slide wheel onto axle. Repeat on other side.5. On the drive side of the axle, insert the small clevispin through the holes in the wheel and axle, Figure3. Install Small Cotter Pin.Axle Bearing1008146 Rev. A 51008146 Rev. A66.On the other side of the axle install a wheel washer and rue ring locking pin, Figure 4.7.Place hopper onto frame. IMPORTANT! Note orientation of rate dial. Be sure to slide spinner shaft into hopper , Figure 5.8.Insert 1/4" Nylon Washer onto 1/4-20 x 1-3/4" Bolt. Insert through hopper and frame. Attach finger tight only with 1/4" Nylon Insert Locknut, Figure 5. Repeat for remaining 3 bolts, washers,and nuts. Tighten fully.9.Slide felt washer over spinner shaft, Figure 6. Insert Agitator wire by sliding through the hole in the spinner shaft as shown. IMPORTANT: Note orientation of agitator wire when installing.Figure 61008146 Rev. A710. Install Hitch Tow Bar onto frame, Figure 7. Attachwith 1/4-20 x 1-3/4" Bolt and 1/4" Nylon Insert Locknut.11. Install Hitch Plates to end of Tow Bar using 1/4-20x 1-3/4" Bolts and 1/4" Nylon Insert Locknuts, Figure 8. Install Hitch Pin and Large Cotter Pin, Figure 8.12. Slide Control Lever into U shaped bracket asshown, Figure 9. The label on the U shaped bracket faces the hopper .13. Install Control Linkage into Control Lever . NOTEorientation of on-off label on U shaped bracket. The shorter section of linkage should face upward and away from lever as shown, Figure 9.Longer Section of LinkageShorter Section of LinkageLabel14. Install 1/4-20 x 1-1/4" Bolt and 1/4" Washerthrough the U shaped bracket, Figure 10.15. From inside the bracket install Nylon Spacer , ThickNylon Washer then through Control Lever. Install second 1/4" Washer and 1/4" Nylon Insert Locknut. Tighten.SpacerThick Nylon Washer 1/4” Washer1/4” Nylon Insert Locknut 1/4-20 x 1-1/4” Bolt1/4” WasherFigure 9Figure 1016. Turn Control Bracket assembly sideways as shown,Figure 11. Install end of linkage into rate gatebracket.17. Install front of control lever assembly onto Tow Barwith 1/4-20 x 1-3/4" Bolt, 1/4" Washer (oneon each side of tow bar) and 1/4" Nylon InsertLocknut, Figure 12. Do not fully tighten at thispoint.1008146 Rev. A818. Install Frame Braces to Frame using 1/4-20 x1-3/4" Bolt, 1/4" Washer (one on each side) and1/4" Nylon Insert Locknut, Figure 13.19. Attach Frame Braces to Tow Tube/Control LeverAssembly using 1/4-20 x 2" Bolt, 1/4" Washers(one on each side), and 1/4" Nylon Insert Locknut.20. With rate gate dial set to 0, move control leverback and forth and ensure rate gate opens andcloses fully, Figure 14. If necessary adjust ControlLever Bracket assembly forward or necessary. Fully tighten hardware from steps 17 and 19 that holdControl Lever Bracket in place.21.Install Screen into Spreader.Rate GateFigure 141008146 Rev. A9READ BEFORE USING OPERATE SAFEL YKeep bystanders away when you operate this machine. Use this machine for intended purpose only.Do not let children or an untrained person operate machine.Keep all parts in good condition and properly installed. Fix damaged parts immediately. Replace worn or broken parts.Do not modify the machine or safety devices. Unauthorized modifications to the machine may impair its function and safety, and void the warranty.Do not let anyone sit or ride on equipment during operation. Keep riders off attachment.Wear substantial footwear and long trousers. Do not operate the equipment when barefoot or wearing open sandals.Do not wear loose fitting clothing that can get caught in moving parts.Always wear eye protection when operating the equipment.Stay alert for holes in the terrain and other hidden hazards.Watch out for traffic when crossing or near roadways. Before you operate any feature of this machine, observe your surroundings and look for bystanders.Always wash hands after contact with fertilizers and pesticides.Keep all nuts, bolts and screws tight to be sure the equipment is in safe working condition.1008146 Rev. A10Become Familiar With The Operation Of The Spreader BeforeYou Put Material In The Hopper• Practice walking with the spreader, opening and closing the rate gate at the appropriate times.• Travel at a constant speed and operate the spreader lever position. Remember: Open the rate gate after the spreader is in motion at operating speed (about3 mph, or at a brisk walking pace).• Close the rate gate while spreader is still at operational speed.Dial Setting InformationThe RATE DIAL has 9 numbers with 10 stops between each number. This allows for accurate control of the spreading rate. The dial is set with only a turn, it will automatically lock into the set position. LINE UP THE DIAL NUMBER WITH THE DIAL INDICATOR.• The spread width ranges from 4 - 12 ft. wide depending on the volume/density, particle size of the material, and rate of travel.• The spread thins or feathers at the outer edges, eliminating sharp, "Edge Of Spread" lines whichcause stripes and streaks. Extra coverage can begiven under trees and other heavy feeding areaswithout showing "Edge Of Spread" lines.• Gaps and double overlaps are less likely. Small errors in travel are forgiven and do not show.WARNING: When spreading products containing herbicides, exercise extreme caution with respect to careless spreading and to wind-drift.Contact Of Some Products On Some Plants Can Be FatalIf a dial setting is not found, use the size and weight comparison table found in this manual. Determine a dial setting on the low side. If the setting proves tobe too low, cover the area more than one time. A higher setting can be used when a proven dial setting is established.Remember: Published dial settings are approximate only. The operation of the spreader, the condition of the material (damp or dry or over-pulverized) and weather conditions, are all contributing factors.For these reasons, it is often a good idea to spread the area 2 times - or one-half rate - in cross directions (SEE INFORMATION ON ONE-HALF RATE DIAL SETTINGS). One-half rate dial settings are highly recommended under damp and humid conditions.Rotary AgitatorUse the rotary agitator only if needed. Free-flowing, lump-free materials will not require the agitator. The rotary agitator is easily installed or removed. Note the clockwise rotation and sweep. Place felt washer aroundspinner shaft before inserting agitator.Now You Are Ready To Put Material In The Hopper WARNING: Avoid Injury! Chemicals can be dangerous. Avoid injury to operators or bystanders.• Make sure the rate gate is in the closed position.• Read chemical container label for handlinginstructions. A Material Safety Data Sheet (MSDS)should be supplied by the chemical dealer andprovides proper safety information.1008146 Rev. A11• Wear proper clothing and safety equipment while handling or applying chemicals.• Prohibit all smoking, drinking, and eating around chemicals.• When spreading products containing herbicides, exercise extreme caution with respect to carelessspreading and to wind-drift. Contact Of SomeProducts On Some Plants Can Be Fatal.• Fill the spreader on a flat, level surface only. Fill on sidewalk, driveway, cardboard, etc. to avoid material loss.• When filling hopper with material, always use screen to help break up clumps.Now You Are Ready To Spread• Keep spinner blade clean. Excess material build-up can cause an uneven spread pattern.• Keep the impeller level when spreading.• DO NOT overload. Maximum capacity of 12520 Series is 125 lbs. Maximum capacity of 17520Series is 175 lbs.• DO NOT use on windy days.• Spread header strips at the ends of the area OPPOSITE of the direction of spreading. This willprovide a "turn-around" area, an area to re-align the spreader for the return spread.• Example shown is for 6 ft. wide spread. Make the first spread pass at one-half the spread width from the edge of the spreading area or in this case,approximately 3 feet (or one big step).• Additional spreading passes will be at the full spread width or approximately 6 ft. apart.• TAKE A SIGHTING AT THE FAR END. Keep your eye on the sighting as you spread. You will not needto wonder where you are or where you have been.Continue until spreading is completed.• Left over fertilizer can be spread under trees and other high feeding areas without showing "edge ofspread" lines.Cleaning The Spreader Is Part Of The Spreading JobClean and oil spreader immediately after each use. Method #1 - Wipe spreader thoroughly with an oily cloth. Oil all bearings and bearing areas.Method #2 - Wash, rinse, and dry the spreader. Note: Drying takes time. Moisture trapped in bearing areas is slow to go. Immediately after drying - oil all bearings and moving parts. Make certain all operations are thorough. NOTE: Good "Dry Cleaning" is preferable to poor "Wet Cleaning".• It is virtually impossible to have rust and corrosion ona clean, dry, oiled surface.• Again - just before using - oil all bearings and moving parts.• In storage, ideally the spreader should be hung by the handle. In any case, do not pile weight on thespreader, as excess weight over a period of time can distort the tires.Oil Bearings And All Moving PartsMake sure the spreader is running freely!1008146 Rev. A12ACCUWA Y - What It DoesThe Accuway Spread Pattern Equalizer Balances the spread pattern - Bulls Eye - Dead to the Center of the Spreader.All products. All spreading conditions.Skewing is eliminated. Does not change the spread width.ACCUWA Y - How It WorksAccuway shifts the material placement on the spreader spinner fan. This in turn, balances the pattern heavier to the right or heavier to the left.Spread pattern can be affected by many variables such as humidity, temperature, wind, spreader condition, speed of travel, material size and weight. Because of these variables, the diffuser must be adjusted for each type of application. Proper adjustment will minimize skewing and uneven coverage.Adjustment is very sensitive. Turning the Accuway Diffuser Knob just a little will result in a drastic change to the spread pattern.The Accuway Diffuser Plate has a front and a rear ramp. Never adjust so that the diffuser plate splits the material flow to both the front and rear ramp at the same time.If the spreader is spreading to the left of center, turn the diffuser knob counterclockwise fully. Then adjust clockwise until the edge of the diffuser plate centers the spread.If the spreader is spreading to the right of center, turn the diffuser knob clockwise fully. Adjust counterclockwise until the edge of the diffuse plate centers the spread. NEVER USE ACCUWAY FRONT AND REAR RAMPS TO SPLIT THE PRODUCT FLOW. Use only the front side or the back side. With proper adjustment you should beable to achieve a balanced spread pattern.1008146 Rev. A131008146 Rev. A14Spreader does not sit flat The "feet" or the flattenedportion of the spreader hoppersupport tubes are not benting a hammer or pliers, bend the feet to be equal with each other.Deflector shut off is binding and will not open/close properlyShut off plate is jammed withdebris.Thoroughly wash out hopperand shut off plates with water.Ensure debris is not stuckbetween shut off plate andrate gate plate. TROUBLESHOOTING1008146 Rev. A 151008146 Rev. A。
B r a s s V a l v e s : V i s u a l I n d e xTable of ContentsVisual Index ............................................................................................................................H2Ball Valves ..............................................................................................................................H6 Wide range of brass, carbon steel and stainless steel ball valves. For use as fuel shut-off lines and other general purpose applications that require shut-off capability.Note: Please refer to Catalog 3501-E for special working pressures and other technical data.Drain Cocks ..........................................................................................................................H11 System temperature and the type of tubing should be considered. Ground plug shutoffs are designed to withstand 30 psi working pressure. Drain cocks are designed to withstand up to 150 psi working pressure, unless otherwise noted.Needle Valves .......................................................................................................................H12 Up to 150 psi working pressure, unless otherwise noted.Truck Valves ..........................................................................................................................H14 Up to 150 psi working pressure, unless otherwise noted.“How to Order” Information .....................................................................................................18Chemical Compatibility Guide..................................................................O10, Visual IndexIndustrial ValvesXV500PFemale-Female page H6XV500HP-XFemale-Female (Large)page H6XV502PPanel Mount page H7XV520PEconomy Series page H9XV533P3 Way Diversionpage H9XV540P4 Waypage H9XV600P6 Port Diversionpage H9XV633P6 Port Diversion page H9XV500CSCarbon Steelpage H6XV502CSPanel Mount Carbon Steel page H7XV502SSPanel Mount Stainlesspage H8MV709Micro Valvepage H6MV609Mini Valvepage H6XV501P Male-Female page H7XV590P90° Valve page H9XV590P-X-0490° Valve page H9XV501SSStainless Steelpage H7MV708Micro Valvepage H6MV608Mini Valve page H6XV509PSolder - Solder page H8Female PortsMale- Female PortsSolder PortsB r a s s V a l v e s : V i s u a l I n d e xIndustrial Valves (Continued)XV591P90° Valve page H9XV591P-X-0490° Valve page H9XV506P Female - Female page H8XV506PFemale - Female (Large)page H8XV510PMale - Female page H8XV506CSCarbon Steel page H8XV506HP Straight Thread page H8XV506HP-XStraight Thread (Large)page H8XV500HP-XFemale Portspage H6XV500HP-XFemale Ports (Large)page H6XVP500HP-X Female Ports-Padlockingpage H9XVP500HP-XFemale Ports-Padlocking (Large)page H10XVP500PFemale Ports page H10XVP501PMale - Female page H10XVP502PPanel Mount page H10XVP510PStraight Thread page H10XVP500CSCarbon Steel page H9XVP502CSPanel Mountpage H10XVP502SSStainless Steel page H10XVP506HP-XStraight Thread page H10XVP506HP-XStraight Thread (Large)page H10XVV500PFemale Ports page H10XVV501PMale-Female page H11XVV502PPanel Mount page H11XVVP500PFemale Ports page H11XVVP501PMale-Female page H11XVVP502PPanel Mount page H11XV500P-X-04Female Ports page H6XV501P-X-04Male - Female page H7XV502P-X-04Panel Mount page H7XV510P-X-04Straight Thread page H9XV500CS-X-04Carbon Steelpage H6XV500P-X-21Female Ports page H6XV500P-X-21Female Ports page H6XV502P-X-21Panel Mountpage H7Male-Male PortsStraight Thread PortsStraight ThreadPorts-High PressureFemale Ports-High PressureFemale Ports-Padlocking- High PressurePadlockingVentedStraight Thread Ports-Padlocking-High PressureVented-PadlockingTee HandleOval HandleB r a s s V a l v e s : V i s u a l I n d e xIndustrial Valves (Continued)XV500CS-X-21Carbon Steelpage H6XV502CS-X-21Panel Mount - Carbon Steelpage H7XV502SS-X-21Oval Handlepage H8XV502SS-X-20Panel Mount page H8NV101F Female - Malepage H12NV102FFlarepage H12NV103FFlare - Male Pipepage H13NV104C-NV104CACompression - Pipepage H13NV105C-NV105CACompressionpage H13NV106C-NV106CACompression - Pipepage H13NV107PPipepage H13NV108PFemale - Malepage H13NV109PFemalepage H13NV311PPoly-Titepage H13NV312PPoly-Titepage H13V203F Flarepage H11V204FFlare - Pipepage H12V303C-V303CACompressionpage H12V304C-V304CACompression - Pipepage H12V401PPipepage H12V402PFemale - Pipepage H12V403PFemalepage H12V406P3 Waypage H12V407P4 Waypage H12DC601Pipepage H11DCR601Internal Sealpage H11DC602Internal Sealpage H11DC603Internal Sealpage H11DC604External Sealpage H11DC606External Sealpage H11DC607Bib Drainpage H11XV502P-X-ACTActuatorpage H7XV502P-X-SUBSub-Assemblypage H7HV104C-KITHumidifier Valve Kit page H12SPV104C-KITSelf Piercing Kit page H13HV104CHumidifier Valvepage H12Short HandleNeedle ValvesShutoff ValvesDrain CocksAuxiliaryB r a s s V a l v e s : V i s u a l I n d e xTransportation: Compression Style ValvesV408NTAT ube - Pipe page I16V410NTAT ube - Pipe page I16V412FTube - Flarepage H14V404PHose - Pipepage H14V404PHHose - Pipepage H14SV404PHose - Pipepage H14V409F Flare - Pipe page H14V405PFemale - Malepage H14Tube to Male PipeHose to Male PipeFemale Pipe to Male PipeFlare to Male PipeB r a s s V a l v e s : B a l l V a l v e sMV608Male-Female Pipe Ends,Compact Handle, Mini Ball ValvePart Number Pipe Thread MV608-21/8MV608-41/4MV608-63/8MV608-81/2MV609Female Pipe Ends, Compact Handle, Mini Ball ValvePart Number Pipe Thread MV609-21/8MV609-41/4MV609-63/8MV609-81/2MV609-6-43/8x1/4MV708Male-Female Pipe Ends, Mini Ball ValvePart Number Pipe Thread MV708-21/8MV708-41/4MV709Female Pipe Ends, Mini Ball ValvePart Number Pipe Thread MV709-21/8MV709-41/4XV500CSFemale-Female Pipe EndsPart Number Pipe Thread XV500CS-41/4XV500CS-63/8XV500CS-81/2XV500CS-123/4XV500CS-161Ball Valves XV500CS-X-21Oval Handle, Female Pipe EndsPart Number Pipe Thread XV500CS-4-211/4XV500CS-6-213/8XV500CS-8-211/2XV500CS-12-213/4XV500CS-16-211XV500CS-X-04Tee Handle,Female Pipe EndsPart Number Pipe Thread XV500CS-4-041/4XV500CS-6-043/8XV500CS-8-041/2XV500CS-12-043/4XV500CS-16-041XV500HP-X6000 PSIFemale-Female Pipe EndsPart Number Pipe Thread (NPT)XV500HP-41/4-18XV500HP-63/8-18XV500HP-81/2-14XV500HP-123/4-14XV500HP-161-11.5XV500PFemale-Female Pipe EndsPart Number Pipe Thread XV500P-41/4XV500P-63/8XV500P-81/2*XV500P-123/4**XV500P-161*** PTF Special Short.** PTF Special Extra ShortXV500P-X-04Tee Handle,Female Pipe EndsPart Number Pipe Thread XV500P-4-041/4XV500P-6-043/8XV500P-8-041/2*XV500P-12-043/4**XV500P-16-041*** PTF Special Short.** PTF Special Extra ShortXV500P-X-21Oval Handle, Female Pipe EndsPart Number Pipe Thread XV500P-4-211/4XV500P-6-213/8XV500P-8-211/2*XV500P-12-213/4**XV500P-16-211*** PTF Special Short.** PTF Special Extra ShortXV500HP-X (LARGE)6000 PSIFemale-Female Pipe EndsPart Number Pipe Thread (NPT)XV500HP-20 1 1/4-11.5XV500HP-24 1 1/2-11.5XV500HP-322-11.5XV500P-20, XV500P-24, XV500P-32Female-Female Pipe EndsPart Number Pipe Thread (NPT)XV500P-201-1/4XV500P-241-1/2XV500P-322B r a s s V a l v e s : B a l l V a l v esXV501SS Male-Female Pipe EndsPartNumber Pipe Thread (NPT)XV501SS-41/4XV501SS-63/8XV501SS-81/2XV501SS-123/4XV501SS-161XV502CS-X-21Oval Handle,Female Pipe Ends, Panel MountPart NumberPipe Thread XV502CS-20-211-1/4XV502CS-24-211-1/2XV502CS-32-212XV502CSFemale-Female Pipe Ends, Panel MountPart Number Pipe Thread XV502CS-201-1/4XV502CS-241-1/2XV502CS-322XV502P-X-21Oval Handle,Female Pipe Ends, Panel MountPart Number Pipe Thread XV502P-4-211/4XV502P-6-213/8XV502P-8-211/2*XV502P-12-213/4**XV502P-16-211*** PTF Special Short.** PTF Special Extra ShortXV502P-X-04Tee Handle, Female Pipe Ends, Panel MountPart Number Pipe Thread XV502P-4-041/4XV502P-6-043/8XV502P-8-041/2*XV502P-12-043/4**XV502P-16-041*** PTF Special Short.** PTF Special Extra ShortXV502PFemale-Female Pipe Ends, Panel MountPart Number Pipe Thread XV502P-41/4XV502P-63/8XV502P-81/2*XV502P-123/4**XV502P-161*** PTF Special Short.** PTF Special Extra ShortXV502P-X-ACTRotary Actuator, Female Pipe EndsPart Number Size Mounting Holes XV502P-4-ACT 1/41/4-20 UNC XV502P-6-ACT 3/81/4-20 UNC XV502P-8-ACT 1/21/4-20 UNC XV502P-12-ACT 3/41/4-20 UNC XV502P-16-ACT11/4-20 UNCXV502P-X-SUBActuatorSub-AssemblyPart Number Size UNCXV502P-4-SUB 1/410-24XV502P-6-SUB 3/810-24XV502P-8-SUB 1/210-24XV502P-12-SUB 3/410-24XV502P-16-SUB110-24XV501P Male-Female Pipe Ends Part Number Female Pipe Thread (PTF)Male Pipe Thread (NPTF)XV501P-41/41/4XV501P-63/83/8XV501P-81/2*1/2XV501P-123/4**3/4*XV501P-161**1** PTF Special Short.** PTF Special Extra ShortXV501P-X-04Tee Handle,Male-Female Pipe EndsPartNumber Female Pipe Thread (PTF)Male Pipe Thread (NPTF)XV501P-4-041/41/4XV501P-6-043/83/8XV501P-8-041/2*1/2XV501P-12-043/4**3/4XV501P-16-041**1* PTF Special Short.** PTF Special Extra ShortXV501P-X-21Oval Handle, Male-Female Pipe EndsPartNumberFemale Pipe Thread (PTF)Male Pipe Thread (NPTF)XV501P-4-211/41/4XV501P-6-213/83/8XV501P-8-211/2*1/2XV501P-12-213/4**3/4XV501P-16-211**1* PTF Special Short.** PTF Special Extra ShortB r a s s V a l v e s : B a l l V a l v e sXV502SSFemale Pipe Ends, Panel MountPart Number Pipe Thread (NPT)XV502SS-41/4XV502SS-63/8XV502SS-81/2XV502SS-123/4XV502SS-161XV502SS-201-1/4XV502SS-241-1/2XV502SS-322XV502SS-X-20Short Handle, Female Pipe Ends, Panel MountPart Number Pipe Thread (NPT)XV502SS-4-201/4XV502SS-6-203/8XV502SS-8-201/2XV502SS-X-21Oval Handle,Female Pipe Ends, Panel MountPart Number Pipe Thread (NPT)XV502SS-4-211/4 XV502SS-6-213/8 XV502SS-8-211/2 XV502SS-12-213/4 XV502SS-16-211XV502SS-20-211-1/4 XV502SS-24-211-1/2 XV502SS-32-212XV506PFemale/Female, Straight Thread O-Ring PortPart Number Straight Thread XV506P-47/16-20XV506P-69/16-18XV506P-83/4-16XV506P-121-1/16-12XV506P-161-5/16-12XV506P-20, XV506P-24, XV506P-32Female/Female, Straight Thread O-Ring PortPart Number Straight Thread XV506P-20 1 5/8-12XV506P-24 1 7/8-12XV506P-322 1/2-12XV509PSolder Cup Number Tube Size XV509P-81/2 XV509P-123/4 XV509P-161XV509P-20 1 1/4 XV509P-24 1 1/2 XV509P-322XV510PMale-Female, Straight Thread O-Ring PortPart Number Straight Thread XV510P-47/16-20XV510P-69/16-18XV510P-83/4-16XV510P-107/8-14XV510P-121-1/16-12XV510P-161-5/16-12XV506CSFemale-Female SAE Straight Thread Ports Part Number Straight Thread XV506CS-47/16-20XV506CS-69/16-18XV506CS-83/4-16XV506CS-121-1/16-12XV506CS-161-5/16-12XV506HP-X (LARGE)6000 PSI Female-Female Straight Thread EndsPart Number SAE J1926-1Thread XV506HP-20 1 5/8-12 UNF XV506HP-24 1 7/8-12 UNF XV506HP-32 2 1/2-12 UNFXV506HP-X6000 PSIFemale-Female Straight Thread EndsPart Number SAE J1926-1Thread XV506HP-47/16-20 UNF XV506HP-69/16-18 UNF XV506HP-83/4-16 UNF XV506HP-12 1 1/16-12 UNF XV506HP-161 5/16-12 UNFB r a s s V a l v e s : B a l l V a l v e sXV520PBrass Ball ValveNumber Pipe Thread XV520P-41/4-18XV520P-63/8-18XV520P-81/2-14XV520P-123/4-14XV520P-161-11.5XV520P-201-1/4XV520P-241-1/2XV520P-322XV520P-402-1/2XV520P-483XV533PFemale-Female- Female Pipe EndsPart Number Pipe Thread(PTF)XV533P-41/4 XV533P-63/8 XV533P-81/2 XV533P-123/4 XV533P-161XV540PFemale-Female-Female-Female Pipe EndsPart Number Pipe Thread (PTF)XV540P-41/4XV590P 90° Flow, Male-Female Pipe EndsPart Number Pipe Thread(PTF)XV590P-41/4XV590P-63/8XV590P-81/2*XV590P-161*** PTF Special Short** PTF Special Extra ShortXV591P90°Flow,Male-Male Pipe EndsPart Number Pipe Thread XV591P-41/4XV591P-63/8XV591P-81/2XV590P-X-04Lever Handle, 90° Flow, Male-Female Pipe EndsPart Number Pipe Thread (PTF)XV590P-4-041/4XV590P-6-043/8XV590P-8-041/2*XV590P-16-041*** PTF Special Short** PTF Special Extra ShortXV510P-X-04 Tee Handle, Straight Thread O-Ring PortPart Number Straight Thread XV510P-4-047/16-20XV510P-6-049/16-18XV510P-8-043/4-16XV510P-10-047/8-14XV510P-12-041-1/16-12XV510P-16-041-5/16-12XV591P-X-04Lever Handle, 90° Flow, Male-Male Pipe EndsPart Number Pipe Thread XV591P-4-041/4XV591P-6-043/8XV591P-8-041/2XV600PSix Port Diversion Brass ValvePart Number Pipe Thread Top Port SPL Short Bottom Port PTF XV600P-8-61/23/8XV633PSix Port DiversionBrass ValvePart NumberPipe Thread Top Port SPL Short BottomPort PTFXV633P-8-61/23/8XVP500CSLocking Handle,Female Pipe EndsPart Number Pipe Thread XVP500CS-41/4XVP500CS-63/8XVP500CS-81/2XVP500CS-123/4XVP500CS-161XVP500HP-X6000 PSI Locking-Female-Female Pipe EndsPart Number Pipe Thread (NPT)XVP500HP-41/4-18XVP500HP-63/8-18XVP500HP-81/2-14XVP500HP-123/4-14XVP500HP-161-11.5B r a s s V a l v e s : B a l l V a l v e sXVP500HP-X (LARGE)6000 PSILocking-Female- Female Pipe EndsPart Number Pipe Thread (NPT)XVP500HP-20 1 1/4-11.5XVP500HP-24 1 1/2-11.5XVP500HP-322-11.5XVP500PLocking Handle, Female Pipe EndsPart Number Pipe Thread For use with 5/16" Ø Shank Lock; .33ØXVP500P-41/4XVP500P-63/8XVP500P-81/2*XVP500P-123/4**XVP500P-161**For use with 9/32" Ø Shank Lock; .31ØXVP500P-201-1/4XVP500P-241-1/2XVP500P-322* PTF Special Short** PTF Special Extra ShortXVP501PLocking Handle, Male-Female Pipe EndsPartNumberFemale Pipe Thread (PTF)Male Pipe Thread (NPTF)XVP501P-41/41/4XVP501P-63/83/8XVP501P-81/2*1/2XVP501P-123/4**3/4*XVP501P-161**1*For use with 5/16" Ø shank lock * PTF Special Short** PTF Special Extra ShortXVP502CSLocking Handle, Female Pipe Ends, Panel MountPart Number Pipe Thread XVP502CS-201-1/4XVP502CS-241-1/2XVP502CS-322XVP502SSLocking Handle, Female Pipe Ends, Panel MountPart Number Pipe Thread (NPT)XVP502SS-41/4 XVP502SS-63/8 XVP502SS-81/2 XVP502SS-123/4 XVP502SS-161XVP502SS-201-1/4 XVP502SS-241-1/2 XVP502SS-322XVP502PLocking Handle, Female Pipe Ends, Panel MountPart Number Pipe Thread XVP502P-41/4XVP502P-63/8XVP502P-81/2*XVP502P-123/4**XVP502P-161**For use with 5/16" Ø shank lock * PTF Special Short** PTF Special Extra ShortXVP506HP-X6000 PSILocking-Female- Female Straight Thread EndsPart Number SAE J1926-1Thread XVP506HP-47/16-20 UNF XVP506HP-69/16-18 UNF XVP506HP-83/4-16 UNF XVP506HP-12 1 1/16-12 UNF XVP506HP-16 1 5/16-12 UNFXVP506HP-X (LARGE)6000 PSILocking-Female- Female Straight Thread EndsPart Number SAE J1926-1Thread XVP506HP-20 1 5/8-12 UNF XVP506HP-24 1 7/8-12 UNF XVP506HP-32 2 1/2-12 UNFXVP510PLocking Handle, Straight Thread O-Ring PortPart Number StraightThread XVP510P-47/16-20XVP510P-69/16-18XVP510P-83/4-16XVP510P-107/8-14XVP510P-121-1/16-12For use with 5/16" Ø shank lockXVV500PVented,Female Pipe EndsPart Number Pipe Thread XVV500P-41/4XVV500P-63/8XVV500P-81/2*XVV500P-123/4**XVV500P-161*** PTF Special Short** PTF Special Extra ShortB r a s s V a l v e s : B a l l V a l v e s , D r a i nC o c k sXVV501P Vented,Male-Female Pipe EndsPartNumberFemale Pipe Thread (PTF)Male Pipe Thread (NPTF)XVV501P-41/41/4XVV501P-63/83/8XVV501P-81/2*1/2XVV501P-123/4**3/4*XVV501P-161**1** PTF Special Short** PTF Special Extra ShortXVV502PVented,Female-Female Pipe Ends, Panel MountPart Number Pipe Thread XVV502P-41/4XVV502P-63/8XVV502P-81/2*XVV502P-123/4**XVV502P-161*** PTF Special Short** PTF Special Extra ShortXVVP502POSHA 29 CFR Part 1910 Vented, Locking Handle, Female Pipe Ends, Panel MountPart Number Pipe Thread XVVP502P-41/4XVVP502P-63/8XVVP502P-81/2*XVVP502P-123/4**XVVP502P-161**For use with 5/16" Ø shank lock * PTF Special Short.** PTF Special Extra ShortXVVP500P OSHA 29 CFR Part 1910 Vented, Locking Handle, Female Pipe EndsPart Number Pipe Thread XVVP500P-41/4XVVP500P-63/8XVVP500P-81/2*XVVP500P-123/4**XVVP500P-161**For use with 5/16" Ø shank lock * PTF Special Short** PTF Special Extra ShortXVVP501POSHA 29 CFR Part 1910 Vented, Locking Handle, Male-Female Pipe EndsPartNumberFemale Pipe Thread (PTF)Male Pipe Thread (NPTF)XVVP501P-41/41/4XVVP501P-63/83/8XVVP501P-81/2*1/2XVVP501P-123/4**3/4XVVP501P-161**1For use with 5/16" Ø shank lock * PTF Special Short** PTF Special Extra ShortDC601Ground Plug Shutoff Temperature Range: +32° to +125°FPart Number Pipe Thread DC601-21/8DC601-41/4DC601-63/8DC601-81/2DC602Internal Seal Drain Cock Temperature Range: -65°F to +250°FPart Number Pipe Thread DC602-21/8DC602-41/4DC603Drain CockTemperature Range: -65°F to +250°FPart Number Pipe Thread DC603-21/8DC603-41/4DC603-63/8DC604External Seal Drain Cock Temperature Range: -65°F to +250°FPart Number Pipe Thread DC604-2*1/8DC604-41/4DC604-6*3/8* When assembled handle wings are down facingDC606External Seal Drain Cock Temperature Range: -65°F to +250°FPart Number Pipe Thread DC606-41/4-18DC607Bib Drain ValveTemperature Range: -65°F to +250°FPart Number Hose Size Pipe Thread DC607-43/81/4DCR601Drain CockTemperature Range: -30°F to +250°FPart Number Pipe Thread DCR601-41/4V203FGround Plug Shutoff Flare to FlareTemperature Range: +32° to +125°FPart Number Tube Size V203F-6-63/8V203F-8-81/2Drain CocksB r a s s V a l v e s : D r a i nC o c k , N e e d l e V a l v e sV204FGround Plug Shutoff Flare to Male Pipe Temperature Range: +32° to +125°FPart Number Tube Size Pipe Thread V204F-4-21/41/8V204F-6-43/81/4V303C / V303CAGround Plug Shutoff Compression to CompressionTemperature Range: +32° to +125°FPart Number Tube Size V303C-4-41/4V303CA-4-41/4V303C-6-63/8V303CA-6-63/8V403PGround PlugShutoff Female Pipe to Female PipeTemperature Range: +32° to +125°FPart Number Female Pipe Thread V403P-2-21/8V403P-4-41/4V403P-6-6*3/8*Made from extruded bar stockV406PThree-way valveFemale Pipe three ends Temperature Range: -40° to +180°FPart Number Pipe Thread V406P-41/4V407PFour-way valveFemale Pipe four ends Temperature Range: -40° to +180°FPart Number Pipe Thread V407P-41/4V401PGround Plug Shutoff Male Pipe to Male Pipe Temperature Range: +32° to +125°FPart Number Pipe Thread V401P-2-21/8V401P-4-41/4Needle Valves NV101FAngle Needle Valve Flare to Male Pipe Temperature Range: -45° to +250°FPart Number Tube Size Pipe Thread NV101F-4-21/41/8NV101F-6-43/81/4NV102FNeedle Valve Flare to FlareTemperature Range: -45° to +250°FPart Number Tube Size NV102F-4*1/4*Provided with Pin HandleHV104CHumidifier ValveTemperature Range: -45° to +250°FPart Number Tube Size Pipe Thread HV104C-4-21/41/8HV104C-kitHumidifier Valve clamp kit Temperature Range: -30°F to +250°FClamp fits 3/8" OD through 1.315" OD tube or pipe. Kit includes 60PT -4 and 63PT -4 for assembly with plastic or nylon tubing. For complete kit, specify entire part number as shown below:Part Number Tube Size Pipe Thread HV104C-4-2 KIT1/41/8V304C / V304CAGround Plug ShutoffCompression to Male Pipe Temperature Range: +32° to +125°FPart Number Tube Size Pipe Thread V304C-4-21/41/8V304CA-4-21/41/8V304C-4-41/41/4V304C-6-43/81/4V304CA-6-43/81/4V402PGround Plug ShutoffFemale Pipe to Male PipeTemperature Range: +32° to +125°FPart Number Female Pipe Thread Pipe Thread V402P-2-21/81/8V402P-4-41/41/4V402P-6-63/83/8B r a s s V a l v e s : N e e d l e V a l v esNV105CA NV105CNV104CNV104CA NV106CANV106C NV103F Needle ValveFlare to Male Pipe Temperature Range: -45° to +250°FPart Number Tube Size Pipe Thread NV103F-4-2*1/41/8*Provided with Pin HandleNV105C-NV105CANeedle ValveCompression to Compression Temperature Range: -45° to +250°FPart Number Tube Size NV105C-4*1/4NV105C-5*5/16NV105C-63/8NV105CA-4*1/4NV105CA-63/8*Provided with Pin HandleNV104C-NV104CAAngle Needle ValveCompression to Male Pipe Temperature Range: -45° to +250°FPart Number Tube Size Pipe Thread NV104C-4-2*1/41/8NV104CA-4-2*1/41/8NV104C-4-41/41/4NV104C-5-2*5/161/8NV104C-6-43/81/4*Provided with Pin HandleNV107PNeedle ValveMale Pipe to Male Pipe Temperature Range: -45° to +250°FPart Number Pipe Thread NV107P-2*1/8NV107P-41/4*Provided with Pin HandleNV108PNeedle ValveFemale Pipe to Male Pipe Temperature Range: -45° to +250°FPart NumberPipe Thread NV108P-2*1/8NV108P-41/4*Provided with Pin HandleNV109PNeedle Valve Female Pipe to Female PipeTemperature Range: -45° to +250°FPart Number Pipe Thread NV109P-2*1/8NV109P-41/4*Provided with Pin HandleNV106C-NV106CA Needle ValveCompression to Male Pipe Temperature Range: -45° to +250°FPart Number Tube Size Pipe Thread NV106C-4-2*1/41/8NV106C-4-4*1/41/4NV106C-5-2*5/161/8NV106C-6-43/81/4NV106CA-4-21/41/8NV106CA-4-4*1/41/4NV106CA-6-43/81/4*Provided with Pin HandleNV311PNeedle ValvePoly-Tite to Male Pipe Temperature Range: 0° to +150°FPart Number Tube Size Pipe ThreadNV311P-4-21/41/8NV311P-4-41/41/4NV311P-6-43/81/4NV312PAngle Needle Valve Poly-Tite to Male Pipe Temperature Range: 0° to +150°FPart Number Tube Size Pipe Thread NV312P-4-21/41/8NV312P-4-41/41/4NV312P-6-43/81/4SPV104C-kitSelf-Piercing Humidifier Valve clamp kitTemperature Range: -30°F to +250°FClamp fits 3/8" OD through 1.315" OD tube or pipe. Kit includes 60PT -4 and 63PT -4 for assembly with plastic or nylon tubing. For complete kit, specify entire part number as shown below:Part Number Tube Size Pipe Thread SPV104C KIT1/41/8B r a s s V a l v e s : T r u c k V a l v esTruck Valves SV404PTruck ValveHose to Male Pipe Temperature Range: -30°F to +250°FPart Number Hose ID Pipe Thread SV404P-10-85/81/2SV404P-12-63/43/8SV404P-12-83/41/2V404PHTruck ValveHose to Male Pipe with Pin HandleTemperature Range: -30°F to +250°FPart Number Hose ID Pipe Thread V404PH-10-65/83/8V404PTruck ValveHose to Male Pipe Temperature Range: -30°F to +250°FPart Number Hose ID Pipe Thread V404P-6-63/83/8V404P-10-65/83/8V405PTruck ValveFemale Pipe to Male Pipe Temperature Range: -30°F to +250°FPart Number Female Pipe Thread Male Pipe Thread V405P-6-63/83/8V405P-6-83/81/2V405P-8-81/21/2V409FTruck ValveFlare to Male Pipe Temperature Range: -30°F to +250°FPart Number Tube Size Pipe Thread V409F-8-61/23/8V409F-8-81/21/2V409F-10-85/81/2V409F-12-83/41/2V412FTruck ValveTube to Male Pipe Temperature Range: -30°F to +250°FPart Number Tube Size Pipe Thread V412F-10-85/81/2。
上海协堡电子有限公司ShangHai ShinePoin Electronics CO.,LTD.地址:上海市闵行区新骏环路115号寰启商务大厦1幢906室TEL:021-********FAX*************上海协堡电子有限公司ShangHai ShinePoin Electronics CO.,LTD.TEL*************FAX*************地址:上海市闵行区新骏环路115号寰启商务大厦1幢906室SLDM-C30/C60激光测距模块产品说明书(中文版)C目录第一章综述....................................................................................................................................1.1 产品简介............................................................................................................................. 第二章工作原理..............................................................................................................................2.1 原理简介............................................................................................................................. 第三章尺寸结构..............................................................................................................................3.1 外形图................................................................................................................................. 第四章技术数据..............................................................................................................................4.1 数据一览表......................................................................................................................... 第五章端口与通讯协议..................................................................................................................5.1 端口一览表......................................................................................................................... 第六章使用方法及步骤..................................................................................................................6.1 使用方法及步骤................................................................................................................. 第七章应用市场..............................................................................................................................7.1 案例场景............................................................................................................................. 第八章应用注意事项......................................................................................................................8.1注意事项.............................................................................................................................. 第九章警告与售后..........................................................................................................................9.1 注意与警告.........................................................................................................................9.2 售后服务............................................................................................................................. 第十章系统拓展与开发..................................................................................................................10.1 说明 ..................................................................................................................................10.2 联系我们...........................................................................................................................第一章综述1.1 产品简介SLDM-C30/C60激光测距模块是新一代测距传感装置,产品集功能强大、性能稳定可靠、安装使用方便、应用范围广等诸多优点于一体,是一种性能优良的经济型实时距离监测产品。
BrochureC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e 480 ▪ w w w .c m a f h .c o mBosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operatedSeries 740Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informationPneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to change5/ -way valve, Series 740▶ Qn = 700 - 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 8x1 - Ø 10x1 ▶ Can be assembled into blocks ▶ Manual override: with detent ▶ suitable for ATEX5ATEXfor ATEXFittings - Accessories, Series 74013C o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mBosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operated5/2-way valve, Series 740▶ Qn = 700 - 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 8x1 - Ø 10x1 ▶ Can be assembled into blocks ▶ Manual override: without ▶ suitable for ATEXPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informationPneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to change001 4170Version Diaphragm poppet valve Pilotinternal Sealing principlesoft sealing Mounting on manifold strip PRS stripWorking pressure min./max. 1.5 bar / 10 bar Ambient temperature min./max.-15°C / +60°C Medium temperature min./max.-15°C / +60°C MediumCompressed air Max. particle size50 µmOil content of compressed air0 mg/m³ - 5 mg/m³Materials:Housing Polyoxymethylene; Polyarylamide SealsAcrylonitrile Butadiene RubberD571_740_aa: Min. pilot pressure at port 14 (Z) depending on working pressureC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m4Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operated5/2-way valve, Series 740▶ Qn = 700 - 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 8x1 - Ø 10x1 ▶ Can be assembled into blocks ▶ Manual override: without ▶ suitable for ATEXPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to changeD571_740) flow control screw for exhausts 5 (R) and (S)C o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m5Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operated5/2-way valve, Series 740▶ Qn = 700 - 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 8x1 - Ø 10x1 ▶ Can be assembled into blocks ▶ Manual override: with detent ▶ suitable for ATEXPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informationPneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to change001 4171Version Diaphragm poppet valve Pilotinternal Sealing principlesoft sealing Mounting on manifold strip PRS stripWorking pressure min./max. 1.5 bar / 10 bar Ambient temperature min./max.-15°C / +60°C Medium temperature min./max.-15°C / +60°C MediumCompressed air Max. particle size50 µmOil content of compressed air0 mg/m³ - 5 mg/m³Materials:Housing PolyoxymethyleneSealsAcrylonitrile Butadiene RubberD571_741_aa: maximum control pressure depending on operating pressure b: minimum control pressure depending on operating pressureC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m6Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operated5/2-way valve, Series 740▶ Qn = 700 - 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 8x1 - Ø 10x1 ▶ Can be assembled into blocks ▶ Manual override: with detent ▶ suitable for ATEXPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to changeD571_7461) for pipe Ø 8 x 1) flow control screw for exhausts 5 (R) and (S) ) position indicatorC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m7Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operated5/2-way valve, Series 740 CP▶ Qn = 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 10x1 ▶ Can be assembled into blocks ▶ corrosion-protected ▶ Manual override: without ▶ suitable for ATEXPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informationPneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to change001 4170Version Diaphragm poppet valve Pilotinternal Sealing principlesoft sealing Mounting on manifold strip PRS strip Working pressure min./max. bar / 10 bar Ambient temperature min./max.-15°C / +60°C Medium temperature min./max.-15°C / +60°C MediumCompressed air Max. particle size50 µmOil content of compressed air0 mg/m³ - 5 mg/m³Materials:Housing PolyoxymethyleneSealsAcrylonitrile Butadiene Rubber Front platePolyarylamideD571_740_aa: Min. pilot pressure at port 14 (Z) depending on working pressureC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m8Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operated5/2-way valve, Series 740 CP▶ Qn = 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 10x1 ▶ Can be assembled into blocks ▶ corrosion-protected ▶ Manual override: without ▶ suitable for ATEXPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to changeD571_740) flow control screw for exhausts 5 (R) and (S)C o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m9Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operated5/2-way valve, Series 740 CP▶ Qn = 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 10x1 ▶ Can be assembled into blocks ▶ corrosion-protected ▶ Manual override: with detent ▶ suitable for ATEXPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed informationPneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to change001 4171Version Diaphragm poppet valve Pilotinternal Sealing principlesoft sealing Mounting on manifold strip PRS strip Working pressure min./max. bar / 10 bar Ambient temperature min./max.-15°C / +60°C Medium temperature min./max.-15°C / +60°C MediumCompressed air Max. particle size50 µmOil content of compressed air0 mg/m³ - 5 mg/m³Materials:Housing PolyoxymethyleneSealsAcrylonitrile Butadiene Rubber Front platePolyarylamideD571_746_aa: maximum control pressure depending on operating pressure b: minimum control pressure depending on operating pressureC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m10Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operated5/2-way valve, Series 740 CP▶ Qn = 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 10x1 ▶ Can be assembled into blocks ▶ corrosion-protected ▶ Manual override: with detent ▶ suitable for ATEXPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to changeD571_7461) for pipe Ø 8 x 1) flow control screw for exhausts 5 (R) and (S) ) position indicatorC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m11Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operatedSeries 740AccessoriesPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to changeSubbases and accessories57 7-501Ambient temperature min./max.-15°C / +50°C MediumCompressed air Working pressure min./max.See table belowMaterials:Subbase PolyoxymethyleneSealsAcrylonitrile Butadiene RubberC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m1 Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operatedSeries 740AccessoriesPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to changeDimensionsD898_ 97Tightening torque for all screws max. 5 Nm 1) Inlet plate ) Through plate ) End plate4) Dummy flange5) Adapter for separate air supplyC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m1Bosch Rexroth AG | PneumaticsDirectional valves → Pneumatically operatedSeries 740AccessoriesPart numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 011-05-18, © Bosch Rexroth AG, subject to changeFittings - Accessories, Series 740p89 _900D89 _900C o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mBosch Rexroth AG Pneumatics Ulmer Straße 4D - 30880 LaatzenPhone +49 511 2136 - 0Fax +49 511 2136 - 2 69********************************/pneumaticsThe data speci fi ed above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judg-ment and veri fi cation. It must be remembered that our products are subject to a natural process of wear and aging.© This document, as well as the data, speci fi cations and other informations set forth in it, are the exclusive property of Bosch Rex-roth AG. Without their consent it may not be reproduced or given to third parties.Subject to modi fi cations.Online-PDF Your contact:CanadaBosch Rexroth Canada Corp.3426 Mainway DriveBurlington, Ontario L7M 1A8Tel. +1 905 335-5511Fax +1 905 335-4184AustraliaBosch Rexroth Pty. Ltd.3 Valediction Road Kings Park NSW 2148SydneyTel. +61 2 9831-7788Fax +61 2 9831-5553U.S.A.Bosch Rexroth Corp.1953 Mercer RoadLexington, KY 40511-1021KentuckyTel. +1 859 254-8031Fax +1 859 254-4188Great BritainBosch Rexroth Ltd.Broadway Lane South CerneyCirencester, GL7 5UH GloucestershireTel. +44 1285 86-3000Fax +44 1285 86-3003further contacts:/addresses18-05- 011C o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m。
3The pilot operated proportional directional valves D*1FBare available in 4 sizes:D31FB - NG10 (CETOP 05)D41FB - NG16 (CETOP 07)D91FB - NG25 (CETOP 08)D111FB - NG32 (CETOP 10)The valves are available with and without onboard elec-tronics (OBE).D*1FB OBEThe digital onboard electronics is situated in a robustmetal housing, which allows the usage under rough en-vironmental conditions.The nominal values are factory set. The cable connectionto a serial RS232 interface is available as accessory.D*1FB for external electronicsThe parameters can be saved, changed and duplicated incombination with the digital power amplifier PWD00A-400.The valve parameters can be edited with the commonProPxD software for both versions.The D*1FB valves work with barometric feedback ofthe main stage to the pressure reducing pilot valve. Thepilot control pressure of 25 bar allows high flow rates atmaximum stability.Valves with explosion proof solenoids Ex e mb ll seecatalogue HY11-3343.Download: /euro_hcd - see “Literature”D91FB OBED91FB OBETechnical Features• Progressive flow characteristics for sensitive adjust-ment of flow rate• High flow capacity• Digital onboard electronics optional• Centre position monitoring optionalSeries D*1FB3Ordering CodeD*1FB1) With enlarged connections Ø 32 mm.2)Not for spool type B31 und B32.3)Please order plugs separately. See accessories.4)Please order female connector M12x1 separately (see accessories , female connector M12x1 (order no.: 5004109).Series D*1FB3Series D*1FB OBE D*1FB OBEOrdering Code1) With enlarged connections Ø 32 mm.2)Not for spool type B31 und B32.3)Please order plugs seperately, see accessories .4) For 1 solenoid 0...+10 V respectively 4...20 mA.5) Not for spool position E and K.6) F0, M0 potentiometer supply, W5 command channel & potentiometer supply.7) Please order female connector M12x1 separately (see accessories , female connector M12x1 (order no.: 5004109)Series D*1FB3Technical Data2)Flow rate for different D p per control edge: Q x = Q Nom. · √ D p xD p Nom.1)If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the valveeletronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.Series D*1FB3Technical DataWith electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.Series D*1FB3D*1FB B/E Flow characteristics at D p = 5 bar per metering edge Spool code E01/02Spool codeB31/32*D*1FB B/E OBEFlow characteristics(set to opening point 10 %)at D p = 5 bar per metering edge Characteristic CurvesSpool code E01/02Spool code B31/321)Flow direction depending on ordering code.All characteristic curves measured with HLP46 at 50 °C.Series D*1FB3The neutral position is monitored. The signal changes after less than 10 % of the spool stroke.Monitor SwitchElectrical characteristics of position control M12x1 as per IEC 61076-2-101M12 pin assignment1 + U S 19.2...28.8 V2 Out B: normally open3 0V4Out A: normally closedPlease order female connector M12x1 separately (see accessories, female connector M12x1 (order no.: 5004109).1)Only guaranted with screened cable and female connectorSeries D*1FB3Block DiagramsCode F0, M06 + PE acc. to EN 175201-804Code G0, S06 + PE acc. to EN 175201-804Code W511 + PE acc. to EN 175201-804Series D*1FB3Interface ProgramProPxD interface programThe ProPxD software permits comfortable parameter setting for the module electronics. Via the clearly arranged entry mask the parameters can be noticed and modified. Storage of complete parameter sets is possible as well as printout or record as a text file for further documenta -tion. Stored parameter sets may be loaded anytime and transmitted to other valves. Inside the electronics a non-volatile memory stores the data with the option for recall-ing or modification.The PC software can be downloaded free of charge at /isde – see page “Support" or directly at /propxd.Features• Comfortable editing of all parameters• Depiction and documentation of parameter sets • Storage and loading of optimized parameter adjust -ments• Executable with all actual Windows ® operating systems from Windows ® XP upwards•Plain communication between PC and electronics via serial interface RS232CThe parametrizing cable may be ordered under item no. 40982923.Series D*1FB3Pilot FlowD31FBB/ED41FBB/ED91FBB/ED111FBB/EPilot oil inlet (supply) and outlet (drain)Series D*1FB3DimensionsD31FBD41FBSeries D*1FB3D91FBDimensionsD111FBSeries D*1FB3Dimension with DT04-2P "Deutsch" ConnectorDimensionsSeries D*1FB3Series D*1FB OBEDimensionsD31FB OBED41FB OBESeries D*1FB3Series D*1FB OBE D91FB OBEDimensionsD111FB OBE。
Onshore Oil and GFor Mobile ApplicationsGasThe Onshore Oil a The Onshore Oil a Parker offers a wide variety of for the toughest onshore oil a Parker is committed to supplying products that meet the ever increasing demands of onshore reduce labor and operator safety.increasing demands of onshore energy recovery.Today’s onshore Oil & Gas industry is moving toward smarter machine control toCustomers can re provide solution equipment produ following feature •Automation of functionsVP/VPO/VPL Series ValvesParker’s Pulsar Series valves are ll i d f hi h well suited for high pressure applications where EHProportional XP operation isrequired. These directional control valves are used in hazardous environments in oil and gas applications; providing industry-leading performance while being h fi k i l Integrate 4 sec the first to market EH proportional control valves in this market. There is a transition casting that enables both Series to be combined into one assembly. •VPL Series 30 GPM @ 5000 PSI •VP/VPO Series 55 GPM@4000 PSIPipe Han and Gas Marketand Gas Market f leading mobile products and gas applications.•Proportionally control the torque requirements to extend t b lif d improve tube life•Provide electrohydraulic proportional explosion proof operation for fine metering controlely on Parker to s to improve rig uctivity with the es:f pipe loading Coiled Tubing United Manifold with ctional valvesCustom ManifoldsCustom manifold solutions canbe designed around specific customer requirements.Components are combined in an efficient package for use in areas ndler/Catwalksuch as:•Pipe Handling •Refrac Trucks•Automated Torque Wrenches•Drill RigsSeries V10, V20, V90,VA/VG20, VA/VG35Parker has a full line of open-center valves that are used on cranes, stabilizers and some of the less complex functions. These l d fl f V90 Secti valves accommodate flows from 10-110 GPM and pressures to 3500 PSI.Features:•Low pressure drops•Custom metering spools for optimum function control and d VG35EH Sec productivity •Outstanding relief valve performance•Long life and durability •Sectional designs offer easy servicingAvailable spool positioners are •Available spool positioners are manual, hydraulic-remote and electrohydraulicVA20 Sectional ValvePCL Hydrauli PCL Hydraulic Pr Remote Control V the customer wit Proportional SolenoidsParker offers a true digital controlled solenoid thatprovides superior fine metering of directional val design is well sui environments wh conditions dictat control.Both hand and fo options, and mul available provides superior fine metering.•12 & 24 VDC •Hysteresis <3% •Various length cables •20 Year Proven track history •ATEX Approvedavailable.The robust and s construction pro and repeatable p This hydraulic co control up to 4 G up to 1450 PSI.ional ValveV20EH Sectional ValveV20 Sectional Valvectional Valvec Controllerroportional Valves provide th precise control lves. The rugged ited to tough here hazardous te nonelectrical oot operated ltiple levers are Well Service Rigimplevides reliable performance. ontrol unit can PM at pressuresParker Hydraulics Internationa North AmericaHydraulics Group Headquarters 6035 Parkland BoulevardCleveland, OH 44124-4141 USA Tel: 216-896-3000Fax: 216-896-4031Parker Hannifin Canada Division Industrial Sal Central Region 1042 Maple Avenu Unit 331Lisle, IL 60532 USA Tel: 630-964-0796Great Lakes Regi Parker Hannifin Canada Division 160 Chisholm DriveMilton, Ontario, L9T 3G9 Canada Tel: 905-693-3000Fax: 905-876-1958MexicoParker Hannifin de México Industrial Hydraulic Sales Eje Uno Norte No.100Great Lakes Regi 6035 Parkland Ave Cleveland, OH 441Tel: 216-896-3000Fax: 216-896-4031Gulf Region20002 Standing Cy Spring, TX 77379 U Tel: 817-473-4431Eje Uno Norte No. 100Parque Industrial Toluca 2000Toluca, Edo. de Mexico CP 50100Tel: 52 72 2275 4200Fax: 52 72 2279 9308EuropeHydraulics Group Headquarters La Tuilière 6CH 1163Et S it l d Fax: 888-227-9454Southwest Regio 700 S. 4th Avenue Mansfield, TX 7606Tel: 817-473-4431Fax: 888-227-9454Mid Atlantic and S RegionsCH-1163 Etoy, Switzerland Ph: 41 21 821 8500Fax: 41 21 821 8580Latin AmericaParker Hannifin Ind. e Com. Ltda Hydraulics DivisionAv. Frederico Ritter, 110094930000Cachoeirinha RS Brazil 1225 Old Alpharett Suite 290Alpharetta, GA 300Tel: 770-619-9767Fax: 770-619-9806Midwest Region 8145 Lewis Road Minneapolis, MN 5Tel:763513353594930-000 Cachoeirinha RS, Brazil Tel: 55 51 3470 9144Fax: 55 51 3470 9215Parker Hannifin Argentina S.A.I.C.Stephenson 27111667-Tortuguitas-Malvinas Argentinas Pcia. de Buenos Aires, Argentina Tel: 54 3327 44 4129Fax: 54 3327 44 4199Tel: 763-513-3535Fax: 763-544-3418Northeast Region P.O. Box 396Pine Brook, NJ 070Tel: 973-227-2565Fax: 973-227-2467Northwest Region 6458North Basin A Pan American Division7400 NW 19th Street, Suite A Miami, FL 33126 USA Tel: 305-470-8800Fax: 305-470-88086458 North Basin A Portland, OR 9721Tel: 503-283-1020Fax: 866-611-7308Pacific and Plains 8460 Kass Drive Buena Park, CA 90Tel: 714-228-2509Fax: 714-228-2511Parker Hannifin C Hydraulic Valve 520 Ternes Aven Elyria, Ohio 4403Tel: 440-366-51Fax:44036652© 2012 Parker Hannifin Corporation, all rights reservedFax: al Sales Officeslesue A 6Mobile SalesMobile Sales Organizationand Global Sales 850 Arthur AvenueElk Grove Village, IL 60007 USA Tel: 847-258-6200Fax: 847-258-6299on enue 124-4141 USA 01ypress Drive USA 1Asia PacificParker Hannifin Shanghai Ltd.280 Yunqiao Road,Jin Qiao Export Processing Zone Shanghai 201206, China Tel: 86 21 2899 5000Fax: 86 21 5834 8975P k H ifi H K Ltd 4n 63 USA 14Southeast Parker Hannifin Hong Kong Ltd.Suites 01-04, 20/F,Tower 2, The Gateway,Harbour City, Tsimshatsui,Hong KongTel: 852 2428 8008Fax: 852 2480 4256Parker Hannifin Korea Ltd.18F KAMCO Yangjae Tower ta Rd.005 USA 7655427 USA 18F KAMCO Yangjae Tower949-3 Dogok1-dong, Gangnam-gu Seoul, 135-860, Korea Tel: 82 2 559 0408Fax: 82 2 556 8187Parker Hannifin India Pvt Ltd.Plot No. EL-26, MIDC,TTC Industrial AreaMahape, Navi Mumbai, 400 709, India 58n 058 USA 57n Avenue Tel: 91 22 6513 7081Fax: 91 22 2768 6841Parker Hannifin Australia Parker Hannifin Pty Ltd.9 Carrington RoadCastle Hill, NSW 2154, Australia Tel: 612 9634 7777Fax: 612 9842 5111Avenue 7 USA 08s Region 0621 USA 91South AfricaParker Hannifin Africa Pty Ltd 10 Berne Avenue AeroportKempton Park 1620,Republic of South Africa Tel: 19 610 700Fax: 13 927 213Corporation e Division nue 35 USA 00Bulletin HY14-2406/US,2M, 10/12, PressTech253m/hydraulicvalve。
UNDERCOUNTER DISHWASHER MODELS:KDPM704KPS0(Stainless)Illus.No.Part No.Description1Literature PartsW11323304Owners ManualW11404477Energy GuideW11366142Tech Sheet2Arm,HingeW10920232Left HandW10920230Right Hand3W11377160Cross Brace,Door 4W10273971Screw Illus.No.Part No.Description5Access PanelW11108979Black6Panel,Front(IncludesItem11)W11233313Stainless7W10858705Cover,Handle Pocket8W10919858Insulation,Multi-Layer9W11038694Insulation,SingleLayerIllus.No.Part No.Description10W10919859Insulation,Front Panel11W10692757Barrel Nut,Front Panel12W11170267Screw,Black13Toe PanelW11108991Black14W11364953Screw153400000ScrewIllus.No.Part No.Description1Console Assembly(Includes Insert)W11106346Black2W11084876Jumper,Door3W10889948Jumper,UI4W10711884Screw(Long)5W11091934Latch Assembly(Includes Switch) 6W11351659Control,Electronic7W11025634Bezel,Vent(Also Order Gasket)Illus.No.Part No.Description8W11184028Gasket,Vent9W10348409Screw10W11098822Inner Door Assembly11W11454757Seal,Door Bottom12W11330869Wiring Harness,Main(Includes Thermostat&Fuse)13W11084867Wiring Harness,InnerDoor14W11092649Dispenser Assembly15W11265187Seal,Console/DoorIllus.No.Part No.Description16W11088985Hanger,Control17W11038720Vent Assembly(Includes Fan)(Also Order Gasket)18W11038734Duct,Vent19W11258418Screw20W11397505Fuse,In-lineIllus.No.Part No.Description1W11120458Tub Assembly(includes gasket) 2W11226744Base,Terminal Box3W11035860Gasket,Tub4W11036127Nut,Water Inlet5W11090487Strike,Latch6W11296374Screw7W11165091Seal,Cabinet8W11025993Drip Tray9W11025986Funnel,OverfillProtection10W11025988Funnel Extension118269145Bracket,Undercounter 12W11165093Cover,Tub Corner Illus.No.Part No.Description13W11036170Float Switch14W11184083Plug,Tub15W11289893Water Inlet Assembly16W11455395Leg,Leveling173378128Washer,Pronged Cup183400014Screw,Grounding19W10277003Screw20W11226746Cover,Terminal Box21Side Support,TubW10920122Left HandW10920120Right Hand22W11221921Shiled,Tub Sound23W11132441Terminal BlockIllus.No.Part No.Description24W11362501Miscellaneous PartsBag(Contains2Screws,2Clamps,&2Brackets)25W11104729Nut,Heater Terminal26W11047695Heater ElementAssemblyIllus.No.Part No.Description1W11122133Pump Assembly2W11294352Isolator,Front Motor3W10891545Diffuser,Inlet4W11294350Hanger,Front Motor59741232Screw6W10891547Check Valve,Drain7W11048456Wash Arm Assembly8W11108699Filter Assembly9W10380239Ring,Volute10W11345228Motor&SumpAssembly11W11036663Isolator,Rear Motor 12W11250985Hose,Pressure Illus.No.Part No.Description13W10900387Hose,Suction14W11035709Motor,Drain15W11131184Hose,Drain16W10903468Disc,Diverter17W11025963Bracket,Rear Motor18W11418271Fastener19W11126174Indicator,OpticalWash20370445Clamp,Hose21W11163419Bracket,Thermostat22W11193089Thermostat(Includedwith Main WiringHarness)23W11025970Fill Valve AssemblyIllus.No.Part No.Description24W11122851Clamp,Hose25W11036161Hose26W11036143Clip,Hose27W10466656Clamp,Hose28W11036287Hose,Inlet29W11236576Clamp,Hose30W11039864Grate31371505Clamp,Hose32Diverter Valve Motor(Not Serviced)33W11034556Sump34W10753070CapacitorUPPER WASH AND RINSE PARTSUPPER WASH AND RINSE PARTSIllus.No.Part No.Description1W10872558Feed Tube Assembly2W11039888Retainer3W11039869Sprayarm,Third Level Illus.No.Part No.Description4W11174340Upper SprayarmAssembly5W10903465Cover,DiverterIllus.No.Part No.Description6W10892836Retainer,Docking(2nd Level)7W10892835Retainer,Docking(3rdLevel)Illus.No.Part No.Description1W10847876Dishrack,Upper2W11310287Clip,Stemware3W11180178Leveler,Adjuster Arm4W11180605Clip,Adjuster Arm5W11267699Button,Adjuster Arm6Adjustment AssemblyW11268082Left HandW11268078Right Hand Illus.No.Part No.Description7Track,AssemblyW11212732Left HandW11212734Right Hand8W11268682Handle,DishrackFront9W11268681Handle,Dishrack Rear109741232Screw11W11186528Tine Row,Fold Down12W11179753Clip,PivotIllus.No.Part No.Description13W11179755Positioner14W11170270ScrewIllus.No.Part No.Description1W11224324Dishrack,Lower2W11133746Wheel&TransportAssembly3W11291798Silverware BasketAssembly4W11267718Lid,Silverware Basket Illus.No.Part No.Description5W10056272Tine Row,Fold Down6W11268658Retainer,Flex Row7W10554952Tine Row,Sliding8W11268661Retainer,Sliding TineRowIllus.No.Part No.Description9W11392620Handle,DishrackFront10W11268681Handle,Dishrack Rear119741232Screw12W11267721Utensil BasketIllus.No.Part No.Description1W11127727Rack,Third Level2Track Assembly W11047813Left HandW11047815Right Hand3W11184071Hanger,Tube4W11130709Mount,Dishrack Illus.No.Part No.Description5W11392620Handle,DishrackFront6W11268681Handle,Dishrack Rear79741232Screw8W11202101Cup Guard9W11087823Silverware TrayIllus.No.Part No.Description10W10830577Bracket,Front Hanger11W10830523Drive Box Assembly,Manifold12W11101860Cover,Wash Tube13W10831864Tube,Wash14W10920244Nut,TubOPTIONAL PARTS(NOT INCLUDED) Illus.No.Part No.Description4396277Barrier KitW11381654External Drain Hose,12FTW11365011Power Cord Kit(Straight)W11365014Power Cord Kit(RightAngle)4396672Strain Relief,PowerCord(Metallic)W10685193Compression HoseFitting,Water LineW10278635RP..Fill Hose Kit。
LANDesk准入控制系统技术白皮书蓝代斯克(北京)软件有限公司2009年6月目录1LANDesk产品简介 (1)2产品架构 (3)2.1准入策略管理网络拓扑图(二级架构) (3)2.2管理模式介绍 (3)2.3基于角色的管理 (4)2.4本地帐户管理 (4)2.5客户端部署方式 (4)2.6异构客户端支持 (4)3LANDesk准入管理系统解决方案 (6)3.1LANDesk网关准入解决方案 (6)3.2LANDesk 802.1x 解决方案 (9)3.3LANDesk IPSec 解决方案 (13)3.4LANDesk DHCP 解决方案 (16)3.5集成 Cisco NAC 解决方案 (18)4LANDesk准入管理系统功能介绍 (23)4.1安全性扫描客户端 (23)4.2补丁管理 (24)4.3配置警报 (34)4.4网络连接控制器 (34)4.5LANDesk更新 (36)4.6汇总核心服务器 (37)5LANDesk管理结构与支持环境 (38)5.1典型管理结构图 (38)5.2基本术语 (38)5.3LANDesk准入管理系统核心服务器安装条件及建议配置 (39)5.4客户端代理组件构成及说明 (40)6LANDesk准入系统其它功能 (42)6.1准入网关方案提供的功能 (42)6.1.1优化和分配带宽资源 (42)6.1.2控制与阻断 (42)6.1.3内网可靠可用性增强 (43)6.1.4防DOS攻击 (43)6.1.5防ARP欺骗 (43)6.2安全性扫描客户端其它功能 (44)6.2.1间谍软件查杀 (44)6.2.2防病毒更新 (45)6.2.3安全威胁分析器 (46)6.2.4自定义漏洞 (48)6.2.5应用阻隔器 (49)7LANDesk的管理目标 (51)7.1保证安全 (51)7.2实施控制 (51)7.3提高效率 (51)7.4减轻您的痛苦 (51)附录:LANDesk LDAC网关部署模式及型号 (53)1LANDesk产品简介虽然安全技术发展至今已经有了长足的进步,然而,病毒、蠕虫、间谍软件和其他形式的恶意软件仍然是企业面临的主要问题。
MONOXOR II INSTRUCTION 0019-9113Rev. 8 - May 2010Bacharach, Inc.621 Hunt Valley Circle, New Kensington, PA 15068PH: 1-800-736-4666 • FAX: 724-334-5001 • Web: E-mail:********************Printed in U.S.A. ® Registered Trademarks®WARRANTYBacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in mater i al and manufac t ure and will conform substan t ially to Bacharach Inc.’s ap p licable specifi cations. Bacharach’s liability and Buyer’s remedy under this warranty are limited to the repair or replacement, at Bacharach’s option, of this Product or parts thereof returned to Seller at the factory of manufac t ure and shown to Bacharach Inc.’s reasonable satisfaction to have been defective; provided that written notice of the defect shall have been given by Buyer to Bacharach Inc. within one (1) year after the date of delivery of this Product by Bacharach, Inc.Bacharach, Inc. warrants to Buyer that it will convey good title to this Product. Bacharach’s liability and Buyer’s remedy under this warranty of title are limited to the removal of any title defects or, at the election of Bacha r ach, to the replacement of this Product or parts thereof that are defective in title.All expendable items, such as electrochemical sensors, are warranted for a period of six months.THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF (I) ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRAN-TIES OF MERCHAN T ABILITY AND FITNESS FOR A PARTICULAR PURPOSE: AND (II) ANY OBLIGA T ION, LIABILITY, RIGHT, CLAIM OR REMEDY IN CONTRACT OR TORT, WHETHER OR NOT ARISING FROM BACH A R ACH’S NEGLIGENCE, A CTUAL OR IMPLIED. The remedies of the Buyer shall be limited to those provided herein to the exclusion of any and all other remedies includ i ng, without limita t ion incidental or consequen t ial damages. No agree m ent varying or extending the foregoing warranties, remedies or this limitation will be binding upon Bacharach, Inc. unless in writing, signed by a duly authorized offi cer of Bacharach.A Declaration of ConformityManufacturer'sName:Bacharach,Inc. Manufacturer's Address: 621 Hunt Valley CircleNewKensington,PA15068 ProductName: MONOXORIIConforms to the following product specifi cations EMC: EuropeanDirective89/336/EEC EN500081-1(Emissions)EN500082-1(Immunity)Copyright © 1995-2010 Bacharach, Inc.1WARNING!Because this instrument is used to detect and monitor materials and conditions which are listed by OSHA or others as potentially hazardous to personnel and property, the information in this manual must be fully understood and utilized to ensure that the instrument is operating properly and is both used and maintained in the proper manner by quali fi ed personnel. An instrument that is not properly calibrated, operated and maintained by quali fi ed personnel is likely to provide erroneous information, which could prevent user awareness of a potentially hazardous situation for the instrument user, other personnel and property.If, after reading the information in this manual, the user has questions regarding the op-eration, application or maintenance of the instrument, supervisory or training assistance should be obtained before use. Assistance is available by calling your nearest Bacharach Service Center.Figure 1. Monoxor II1 INTRODUCTIONThe Monoxor® II is a commercial-gradeportable instrument designed to displayconcentrations of carbon monoxide (CO)gas between 0 and 2000 ppm. This instru-ment shows the presence of CO in a gassample by drawing the sample into its sen-sor chamber by a built-in motorized pump.Part #0019-7034 comes with a probe. Part#0019-7039 comes without a probe (Allnon-probe related functions remain thesame in this instruction).Other features and accessories of theMonoxor II include: A large, back-litLiquid Crystal Display (LCD), which al-lows the display to be read in any lightingcondition from direct sun-light to totaldarkness; a semi-detachable elastic strapthat permits the instrument to be eitherhand held, or hung on nearby objects; arigid stainless steel probe with handle,connected to a fl exible hose that allowsgas samples to be taken from crampedand con fi ned areas (alternate probes andcondensate traps may be used).2Figure 2. BatteryInstallation2 TECHNICAL CHARACTERISTICSCO Display Range ...............0-1999 ppm COAccuracy ..............................±10 ppm or ±5% of reading whichever is greater*Response Time .....................90% of fi nal value within 40 sec.Battery Requirements ...........1.5 V , “C” cells, Qty. 4Operating Time** ................14 to 16 hours, alkaline cells Operating Temp. Range .......23 to 104°F (–5 to 40°C)Relative Humidity ................10 to 85% non-condensingWeight (w/o batteries) ..........12 ozs. (341 grams)Dimensions ..........................8.6 x 3.5 x 2.9 in. (218 x 89 x 74 mm)To prepare the instrument for operation, youmust install four “C” size batteries, and (ifdesired) install the hose and probe as describedin the following paragraphs.For your convenience, and to ensure that theinstrument will provide reliable CO indications,the CO sensor is installed and the instrumentcalibrated on 500 ppm of CO at the factory.3.1 Battery InstallationDetach the elastic strap's metal clip at the bottomof the instrument, and slide off the battery coveras shown in Figure 2. Then while observingproper battery polarity, install four “C” sizebatteries into the instrument’s battery compart-ment. (Recommended battery types: DuracellAlkaline or equivalent). After the batteriesare installed, replace the battery cover and theelastic-strap clip.* Tighter accuracy in the lower ranges, up to ±2 ppm, may be attained if lower range calibration gases (eg. 100 ppm) are utilized.** Times are with the backlight turned off. Continuous use of the backlight will decrease battery life.3 PREPARING THE MONOXOR II FOR OPERATIONIf batteries are accidently installed in the wrong polarity, a positive temperature coefficient (PTC) thermistor will protect the instrument’s electronic circuitry. The instrument will operate once batteries are properly installed and the PTC thermistor is allowed to cool.3.2 Probe InstallationInstall the probe by sliding the end of its tubing over the gas inlet port on the top right side of the instrument as shown in Figure 3. The tubing may be diffi cult to slide over the gas inlet port of the unit for the fi rst time. This was done intentionally to allow for a snug fi t. If necessary, use a little dish washing liquid diluted in water or heat the end of the tube with hot tap water to help it slide onto the port.GAS INLET PORTLINEDRYERPROBEHANDLEWhen changingprobe tubes,hand tighten nut,and then use awrench to tighten≈1 fl at to seal.Figure 3. Probe Installation344 OPERATIONTo operate the Monoxor II, you simply . . .• Set its POWER switch to ON,• Wait for the instrument to warm up (approx. 1 minute), • Zero the display (if necessary),• Take a gas sample.Detailed operating procedures are presented below:4.1 Power ON/OFFTurn on the instrument by sliding its POWER switchto ON. Observe that when power is fi rst applied, allnumerical LCD segments are tested for 5–15 sec-onds; after which, the LCD shows the detected CO level. (A minus sign may appear during power up as the sensor stabilizes.) Turn off the instrument by sliding the POWER switch to OFF.Important! When storing the instrument for extended periods of time, remove the batteries and ensure that the POWER switch is OFF . The OFF position places a short across the CO sensor, thus keeping the sensor from being destabilized while not in use.4.2 Zeroing the InstrumentAfter being turned on and warmed up for at least 1 minute, the instru-ment should indicate 000 ±5 ppm in fresh air. If the instrument needs to be zeroed, proceed as follows:1. Ensure that the instrument is sampling air that is free of Carbon Monoxide.NOTE: If the instrument was zeroed in an area where CO was present, a large negative CO display appears.2. Using a 1/8" fl at-blade screwdriver, turn theADJUST potentiometer until the LCD shows0 ppm. The display shows negative numbers forzeroing purposes. An instrument can be considered zeroed with adisplay bounce of up to ±3 ppm.4.3 Backlight ON/OFFThe LCD can be read in low-light areas by setting the front panel LIGHT switch to ON. The backlight stays on until turned off, or until the POWER switch is set to OFF.4.4 Using the StrapThe instrument's elastic strap allows the unit to be either hand-held, or hung on nearby objects.By sliding your hand between the instrument and its elastic strap, you can hold onto the Monoxor II with a minimum of effort. The instrument's front panel slide switches can then be actuated by your thumb for one-handed operation. Or, by releasing the metal clip at the bottom of the instrument's case, you can hang the instrument by its strap on nearby objects such as nails, sheet metal, or valve handles.4.5 Using the ProbeA rigid stainless steel probe with handle is used to draw a gas sample from the room, grilles, diffusers, and furnace flues through a line dryer and fl exible hose into the instrument. A fl exible probe option (see Section 6) is available to give easy access to hot-water heater fl ues and inside furnace heat exchangers.The probe tube is detachable from the handle when sampling with a different probe is desired. See Figure 3.Important! The line-dryer will remove moisture from the gas sample. If the line-dryer becomes saturated, however, condensation may be observed within the hose. If this occurs, stop sampling and replace the line-dryer's fi lter-packing material.4.6 Interpreting the Displayrange from 0 to 1999 ppm. The display on the rightindicates a CO level of 500 ppm.5Overrange When the gas sample exceeds1999 ppm, a “1” is displayed on the LCD. To clearan overrange condition, leave instrument turned onand sample fresh air until the LCD returns to displaying CO.Low Battery Indications W hen the battery voltage Array becomes low, the “LO BAT” indicator appears.Although the instrument will continue to operateand give CO readings under these conditions, the batteries should be replaced as soon as possible.When battery voltage becomes too low for theinstrument to operate, a “-1” is displayed on theLCD. No CO readings are provided under theseconditions.4.7 Long-Term StorageWhen storing the Monoxor II for extended periods of time, set its POWER switch to OFF and remove the batteries. The POWER OFF position places a short across the CO sensor, thus keeping it from being destabilized while not in use.5 MAINTENANCEThe Monoxor II needs to be calibrated at regular intervals to be cer-tain that it still meets its accuracy specifi cation. A regular calibration schedule should be established between you and your nearest Bacha-rach Service Center, unless your facility has the necessary calibration equipment and personnel trained in the maintenance of gas-detection equipment. Detailed calibration , maintenance procedures and re-placement parts lists are provided in the Service Manual (0019-9166). As a quick check of the instrument’s operation, perform a response check by exposing the instrument to a source of CO (e.g., cigarette smoke, smoke from a recently snuffed-out match, bottled CO). If the instrument doesn’t show the presence of CO, or if the reading is obvi-ously in error, DO NOT use the instrument until it has been serviced by an authorized Bacharach Service Center.DO NOT use this simple response check as a sub-NOTE:stitute for ensuring the instrument is properly calibrated.66 PARTS / SERVICE6.1 Parts/Accessories List Item Part No. Battery Cover 0019-3029 Probe/Hose/Line Dryer Assy. 0019-3084 Flexible Probe Tube (optional) 0019-3104 Line Dryer Filter Packing 0011-01226.2 Bacharach Sales / Service Centers 7United StatesBacharach, Inc.621 Hunt Valley CircleNew Kensington, PA 15068Phone: 724-334-5051Fax: 724-334-5723Email:********************Canada Bacharach of Canada, Inc.20 Amber St. Unit #7Markham, Ontario L3R SP4 Canada Phone: 905-470-8985Fax: 905-470-8963Email:*******************7 HAZARDS OF CARBON MONOXIDECarbon monoxide poisoning results in headache, nausea, chronic tired-ness, confusion, dizziness, and sometimes coma or death. It effects people by cutting off the supply of oxygen to their muscles and brain. The harmful effects of carbon monoxide exposure depend on both the concentration of CO in the air and the length of exposure. Concentration Inhalation time and toxicof CO in air symptoms developed50 ppm* (0.005%) Maximum allowable concentration forcontinuous exposure in any 8-hour period. 200 ppm* (0.02%) Slight headache, tiredness, dizziness,nausea after 2–3 hours.400 ppm (0.04%) Frontal headaches within 1–2 hours,life-threatening after 3 hours.800 ppm (0.08%) Dizziness, nausea and convulsions within45 minutes. Unconsciousness within2 hours. Death within 2–3 hours.1,600 ppm (0.16%) Headache, dizziness and nausea within20 minutes. Death within 1 hour.3,200 ppm (0.32%) Headache, dizziness and nausea within5–10 minutes. Death within 30 minutes. 6,400 ppm (0.64%) Headache, dizziness and nausea within1–2 minutes. Death within 10–15 minutes. 12,800 ppm (1.28%) Death within 1–3 minutes.For more information on CO ask about Bacharach'sCO Regional Training Seminars.*Maximum CO concentration for exposure at any time as prescribed by OSHA. Effects can vary signifi cantly based on age, sex, weight and overall state of health.8。
dSPE 2mL High Pigment EN with Carbon S 化学品安全技术说明书GHS product identifier 应急咨询电话(带值班时间)::供应商/ 制造商:安捷伦科技贸易(上海)有限公司中国(上海)外高桥自由贸易试验区英伦路412号(邮编:200131)电话号码: 800-820-3278传真号码: 0086 (21) 5048 2818dSPE 2mL High Pigment EN with Carbon S化学品的推荐用途和限制用途5610-2074, 5610-2075部件号:物质用途:供分析化学实验室使用的试剂和标准管5610-2074 dSPE 2毫升 高色素EN,含碳 S5610-2075 dSPE 2毫升 高色素EN,含碳S,含 CH安全技术说明书根据 GB/ T 16483-2008 和 GB/ T 17519-2013GHS化学品标识:dSPE 2毫升 高色素EN含碳S 有关环境保护措施,请参阅第 12 节。
物质或混合物的分类根据 GB13690-2009 和 GB30000-2013紧急情况概述固体。
[粉末。
]灰色。
无资料。
操作和/或处理此物质可能产生能够导致眼睛,皮肤,鼻腔和喉部机械刺激的粉尘。
物理状态:颜色:气味:GHS危险性类别警示词:无信号词。
危险性说明:没有明显的已知作用或严重危险。
防范说明预防措施:不适用。
事故响应:不适用。
安全储存:不适用。
废弃处置:不适用。
标签要素无法分类。
物理和化学危险没有明显的已知作用或严重危险。
健康危害没有明显的已知作用或严重危险。
::与物理,化学和毒理特性有关的症状眼睛接触:不利症状可能包括如下情况:刺激充血发红皮肤接触食入呼吸道疼痛咳嗽没有具体数据。
没有具体数据。
::延迟和即时影响,以及短期和长期接触引起的慢性影响短期暴露潜在的即时效应:无资料。
潜在的延迟效应:无资料。
潜在的即时效应:无资料。
长期暴露潜在的延迟效应:无资料。
Principle of Operation:Parker Autoclave Engineers’ Wellhead Gauge valves are designed for reliable shut-off service at a maximum working pressure of 30,000 psi (2068 bar). The Wellhead Gauge and Bleed Valves are standard in 316 stainless steel material. Special materials available on request.Wellhead Gauge Features:• One inlet, three outlet ports • Metal-to-metal bubble tight shut-off • Packing below stem threads• Two piece non-rotating stem on standard valvesBleed Valve Features:• One piece hex construction allows easy installation • Vent port tapped for plumbing to safe area • Tee handle for easy operation • Positive blow out prevention on stem • 1/8" NPT outlet connection • O-ring VitonWellhead Gauge Applications:• Sample Lines• Instrumentation CalibrationBleed Valve Applications:• Pressure BleedAll Parker Autoclave Engineers products are designed in accordance with ASME B31.3 Chapter IX High Pressure Piping standards.Needle ValveWellhead Gauge/Bleed ValvePressure to 30,000 psi (2068 bar)2Needle Valves: Wellhead Gauge and Bleed Valves 02-1250SE 0318Wellhead Gauge/Bleed Valve:Pressures to 30,000 psi (2068bar)Bleed Valve 20GV 3/8SM375CX 0.093 (2.36)-20,000 (1379)20GV 9/16SM562CX 0.093 (2.36)-20,000 (1379)30GV9/16M562C0.093 (2.36)-30,000 (2068)*Notes* Rating shown is in closed position.Rating @ 15,000 psi (1034 bar) in open position. Glands and collars includedOrdering Guide:Catalog number is created based on customer selection of product parameters, see below for example.Wellhead Gauge Valve (order individually)3Needle Valves: Wellhead Gauge and Bleed Valves 02-1250SE 0318Material of Construction:Wellhead Gauge Valve Dimensions:All dimensions for reference only and subject to change • For prompt service, Parker Autoclave stocks select products. Consult factory.4Needle Valves: Wellhead Gauge and Bleed Valves 02-1250SE 0318Material of Construction:Ordering Guide:Catalog number is created based on customer selection of product parameters, see below for example.Bleed Valve (order individually)Bleed Valve Dimensions:All dimensions for reference only and subject to change • For prompt service, Parker Autoclave stocks select products. Consult factory.5 Needle Valves: Wellhead Gauge and Bleed Valves 02-1250SE 03186Needle Valves: Wellhead Gauge and Bleed Valves 02-1250SE 0318Electric Valve Actuators :Remotely controlling process flow at high pressure enhances safety and low-ers labor costs. Parker Autoclave Engineers developed a flow control valve available in several models including weatherproof and explosionproof options.The Electrically Actuated Shut-off/Flow Regulating Actuator (FRC Series) is available for most of our Needle Valves through 9/16” tubing size and up to 60,000 psi maximum pressure. They are available in all body patterns except 3-Way / 2-Stem Manifold, and can withstand wide process temperature ranges.Please consult the appropriate needle valve brochure for information on valve options, ratings, flow coefficient, body dimensions, and other specifications.Pneumatic Valve Actuators :The need to control process and vent valves from a remote location makes air operated valves a vital component to many processing operations. All Parker Autoclave Engineers’ valves are available with piston type actuators. Five sizes of air actuators (light, mini-light, medium, heavy duty or extra heavy, single and double stage) are offered to meet the service require-ments of Parker Autoclave Engineers’ Low, Medium and High Pressure needle valves. Both air-to-open (normally closed) and air-to-close (normally open) designs are included in the product line. Optional air to open AND close actuators available upon request. Please see our Pneumatic ValveActuator Brochure to help size the proper actuator for your application.both control and shut-off. While it is not as precise as the control associated with the MicroMetering stem, especially with smaller flows, it does offer substantially better control than the Vee stem.increase service life.7Needle Valves: Wellhead Gauge and Bleed Valves 02-1250SE 0318High/Low Temperature Extension:Not typically needed for 10V/SW Series valves as temperature range does not exceed the barriers below, but option is shown for consideration.-HT High Temperature (over 800°F (427°C))-LTLow Temperature (under -100°F (-73°C))ES Stem Extender:Stem extenders are offered for High and Low temperature operation or to extend through panel or barricade.To order valve with Stem Extender, add “ES-” and length (6”, 12”, 18”, 24”) to beginning of valve part number e.g. ES12-20SM6071. Other lengths to special order.To order Stem Extender only, provide valve model prefix e.g. ES12-20SM6. Handle not included – use same provided with original valve.Needle Valve Clam Shell Handle Lockout:(order separately using part numbers shown below, padlock not included)Clam Shell Handle locks are provided to lockout valves in open or closed position preventing unauthorized personnel from actuating valve during shutdown or emergency situations.This clamshell design is available in four (4) sizes dependent on handle length:P/N AE004855 – 1" to 2.5" handle length P/N 90088 – 2.5" to 5.0" handle length P/N 90194 – 6.5" to 10" handle lengthP/N AE004350 – 8" to 13" handle length! CAUTION !Do not mix or interchange component parts or tubing with those of other manufacturers. Doing so is unsafe and will void warranty.Parker Autoclave Engineers Valves, Fittings, and Tools are not designed to interface with common commercial instrument tubing and are designed to only connect with tubing manufactured toParker Autoclave Engineers AES specifications. Failure to do so is unsafe and will void warranty.Offer of SaleThe items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will begoverned by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).©2018 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation Literature #: 02-1250SE March 2018Parker WorldwideAE – UAE, Dubai Tel: +971 4 8875600********************AR – Argentina, Buenos Aires Tel: +54 3327 44 4129******************AT – Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0*************************AT – Eastern Europe, Wiener NeustadtTel: +43 (0)2622 23501 970****************************AU – Australia, Dandenong Tel: +61 (0)3 9768 5555******************************AZ – Azerbaijan, Baku Tel: +994 50 2233 458****************************BE/LX – Belgium, Nivelles Tel: +32 (0)67 280 900*************************BR – Brazil, Sao Jose dos Campos Tel: +55 12 4009 3504******************BY – Belarus, Minsk Tel: +375 17 209 9399*************************CA – Canada, Grimsby, Ontario Tel +1 905-945-2274*********************CH – Switzerland, Etoy Tel: +41 (0) 21 821 02 30*****************************CL – Chile, Santiago Tel: +56 (0) 2 2303 9640******************CN – China, Shanghai Tel: +86 21 2899 5000*****************************CZ – Czech Republic, Klecany Tel: +420 284 083 111*******************************DE – Germany, Kaarst Tel: +49 (0)2131 4016 0*************************DK – Denmark, Ballerup Tel: +45 43 56 04 00*************************ES – Spain, Madrid Tel: +34 902 33 00 01***********************FI – Finland, VantaaTel: +358 (0)20 753 2500*************************FR – France, Contamine s/Arve Tel: +33 (0)4 50 25 80 25************************GR – Greece, Athens Tel: +30 210 933 6450************************HU – Hungary, Budapest Tel: +36 1 220 4155*************************ID – Indonesia, Tangerang Tel: +62 (0)21 7588 1906********************IE – Ireland, DublinTel: +353 (0)1 466 6370*************************IN – India, MumbaiTel: +91 22 6513 7081-85IT – Italy, Corsico (Ml)Tel: +39 02 45 19 21***********************JP – Japan, Tokyo Tel: +(81) 3 6408 3900******************KR – South Korea, Seoul Tel: +82 2 559 0400*******************KZ – Kazakhstan, Almaty Tel: +7 7272 505 800****************************LV – Latvia, Riga Tel: +371 6 745 2601************************MX – Mexico, Toluca Tel: +52 722 275 4200*******************MY – Malaysia, Selangor Tel: +603 784 90 800*******************NL – The Netherlands, Oldenzaal Tel: +31 (0)541 585 000********************NO – Norway, Stavanger Tel: +47 (0)51 826 300************************NZ – New Zealand, Mt Wellington Tel: +64 9 574 1744PL – Poland, Warsaw Tel: +48 (0)22 573 24 00************************PT – Portugal, Leca da Palmeira Tel: +351 22 999 7360**************************RO – Romania, Bucharest Tel: +40 21 252 1382*************************RU – Russia, Moscow Tel: +7 495 645-2156************************SE – Sweden, Spånga Tel: +46 (0)8 59 79 50 00************************SG – Singapore,Tel: +65 6887 6300*******************SK – Slovakia, Banská Bystrica Tel: +421 484 162 252**************************SL – Slovenia, Novo Mesto Tel: +386 7 337 6650**************************TH – Thailand, Bangkok Tel: +66 2 186 7000*********************TR – Turkey, Istanbul Tel: +90 216 4997081************************TW – Taiwan, Taipei Tel: +886 2 2298 8987*************************UA – Ukraine, Kiev Tel: +380 44 494 2731*************************UK – United Kingdom, Warwick Tel: +44 (0)1926 317878********************USA – IPD, Huntsville Tel: +1 256 881 2040*****************USA – Autoclave Engineers, Erie Tel: +1 814 860 5700*******************VN – Vietnam, Hochi Minh City Tel: +84 (0)8337 546 51**********************ZA – South Africa, Kempton Park Tel: +27 (0)11 961 0700*****************************ISO-9001 CertifiedInstrumentation Products Division Autoclave Engineers Operation 8325 Hessinger Drive Erie, PA 16509-4679Tel: 814 860 5700Fax: 814 860 /ipdusInstrumentation Products Division Autoclave Engineers Operation, Houston15340 Vantage Parkway, East Houston, TX 77032Tel: 281 987 3828Fax: 281 987 2318Parker Hannifin Manufacturing Ltd.Instrumentation Products Division, EuropeRiverside RoadPottington Business ParkBarnstaple, UK, EX31 1NP , UK Tel: 44 1271 313131Fax: 44 1271 373636WARNINGFAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,PERSONAL INJURY AND PROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The prod-ucts described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.Needle Valves: Wellhead Gauge and Bleed Valves 02-1250SE 0318。
1目 录CONTENTS02 06 08 12 15 19 24 28 32 34 38 41 43 4649 56公司简介.......................................................................................................................................................................................................... 频谱分析仪SSA5000A 系列频谱分析仪................................................................................................................................................................... SSA3000X-R 系列实时频谱分析仪.................................................................................................................................................... SSA3000X PLUS 系列频谱分析仪..................................................................................................................................................... SHA850A 系列手持频谱分析仪.......................................................................................................................................................... 频谱&矢量网络分析仪SVA1000X 系列频谱&矢量网络分析仪........................................................................................................................................ 矢量网络分析仪SNA6000A 系列矢量网络分析仪....................................................................................................................................................... SNA5000A 系列矢量网络分析仪....................................................................................................................................................... SNA5000X 系列矢量网络分析仪....................................................................................................................................................... SHN900A 系列手持矢量网络分析仪.............................................................................................................................................. 射频/微波信号发生器SSG6000A 系列微波信号发生器....................................................................................................................................................... SSG5000A 系列微波信号发生器....................................................................................................................................................... SSG5000X 系列射频模拟/矢量信号发生器............................................................................................................................. SSG3000X 系列射频信号发生器....................................................................................................................................................... 探头及附件 其他探头及配件........................................................................................................................................................................................... 售后承诺........................................................................................................................................................................................................... 2通用电子测试测量仪器领域的行业领军企业公司战略Every Bench. Every Engineer. Every Day.深圳市鼎阳科技股份有限公司(简称“鼎阳科技”,股票代码:688112)是通用电子测试测量仪器领域的行业领军企业,A 股上市公司。
The ESDF4In Line Joint is an underground joint suitable for direct burial and underground chamber applications.It is used for the jointing and branching of optical cables,and has a total capacity of 72fibres.The joint is supplied with six splice trays each able to accommodate up to 12fibre splices.Cable Entry Glands,Splice Protectors and Mounting Brackets are ordered separately to suit the application requirements.Prysmian Part Number:XJTSC00083ESDF4In-Line JointNote:Cable entry glands are supplied as separate itemsFeatures and Benefits•Installation in an underground chamber or direct buried.•Six splice trays are each able to accommodate 12spliced fibres.•Maximum spliced fibre capacity is 72fibres.•Between 4and 16cable entries dependant on cable diameter.•Mechanical cable sealing.•Cable anchor system allows cables to be prepared away from the joint.•Continuous addition of branched cables possible for up to 4cables per port.•Reliable sealing of the box using a mechanical gasket allows easy entry.•Suitable for direct buried applications.•Pole and Wall mounting brackets available.•Earth point for cables metallic parts.Kit ContentsThe ESDF4In Line Joint is supplied with 6splice trays.Cable Entry Kits,Mounting Brackets and Splice Protectors must be ordered separately.Note:Four Cable Entry Kits must be ordered per joint.If only two cables are required,blank entry kits must be used to seal the joint.Additional Items•Cable Entry Kits •Wall Mounting Bracket •Pole Mounting Bracket •Splice ProtectorsLogisticsTechnical Data•Number of cable ports:4–16(depending on diameter)•Maximum cable diameter (mm):25•Maximum number of trays:6•Maximum fibre capacity:72•Required space envelope (mm):(l)500x (w)160x (d)90•Operating temperature:-20o C to +50o C (5to 95%RH)•Material:-•Closure:Glass Filled Nylon •Splice trays:FR ABS•Testing:-•Closure Sealing IP68•Optical:Tested at 1310nm,1550nm and 1625nm •Drop:EN 60068-2-32•Salt Mist:NF C 20-711•Vibration:EN 60068-2-6•Shock:EN 50102•Packing Dimensions (mm):(l)580x (w)180x (d)110•Packed Weight (kg): 3.3•Net weight (kg):3.0•Installation Instructions includedILJ Cable Entry Kits are used to install cables into an In Line Joint.One kit contains all of the components required to prepare,install and route the fibres of one cable to the splice trays.Four Cable Entry Kits must be used.If only two cables are required to be installed,then two blank kits must be ordered also.(Kits are available for installing one,two or four cables into a port,depending on the cable diameter).Prysmian Part Numbers:-Blank Entry –XJTSC00084-To seal unused portsSingle Entry –XJTSC00085-For one cable up to 25mmDouble Entry –XJTSC00086-For two cables up to 12.5mm each Quad Entry–XJTSC00087-For four cables up to 9mm eachESDF4ILJ Cable Entry KitsAdditional ItemsThe ILJ Wall Mounting Bracket is used for mounting the In Line Joint to a wall.The bracket is supplied with the appropriate fixings.Prysmian Part No.–XJTSC00088Wall Mounting BracketAdditional Items ContinuedThe ILJ Pole Mounting Bracket is used for mounting the In Line Joint to a Pole.The bracket is supplied with the appropriate fixings.Prysmian Part No.–XJTSC00089Pole Mounting BracketSplice protectors are used to protect the fibre splice.They are 2.2mm in diameter and 45mm in length.Prysmian Part No.-XPESC00053(pack of 50)-XKTSC00050(pack of 12)Heat Shrink Splice ProtectorsThe Crimp Splice Protector Kit is used to convert the splice tray in an In Line Joint to accommodate crimp splice protectors.One kit is required for each splice tray.The kit contains an insert to house the splice protectors and 12crimp splice protectors.Prysmian Part No.–XKTSC00020Crimp Splice ProtectorsPrysmian Group 2012,All Rights Reserved.The information contained within this document must not be copied,reprinted or reproduced in any form,either wholly or in part,without the written consent of Prysmian Group.The information is believed correct at the time of issue.Prysmian Group reserves the right to amend this specification without notice.This specification is not contractually valid unless specifically authorised by Prysmian Group.Please contact your local sales office listed on 。
ModelCatalog NumberParts Manualc For Technical Assistance call: 800-227-2233, Fax: 888-329-8207To Order Parts call: 888-227-2233, Fax: 888-329-0234Paper Roll Clamp18H 35532cascadecorporationBlank6781235Decals H-Series Roll ClampREF QTY PART NO.DESCRIPTION16665595No Hand Hold Decal23660269Short Arm Rotation Position Decal 34656038Caution Decal 44679150No Step Decal54665677Trapped Pressure Decal 61679059Quick-Change Hook Decal 716038786Visibility Warning Decal 816093628Split Arm Decal – Type 1 u 16096928Split Arm Decal – Type 0 uu See stamp on Revolving Connection for correct Type.PublicationsH-Series Roll Clamp PART NO.DESCRIPTION 6078255Service Manual210135Operators Guide – Fixed Frame 676268Operators Guide – Swing Frame 6077316Installation Instructions – Fixed Frame 6095756Installation Instructions – Swing Frame 679929Tool Catalog673964Literature Index Order FormRotator Group18HREF QTY PART NO.DESCRIPTION REF QTY PART NO.DESCRIPTION 6858653Rotator/Baseplate Group132768518Capscrew6857838Frame Group ★142206323Lockwasher 116857839Frame1516610Plug216858646Baseplate16186055606Capscrew316800068Bearing Assembly♦1736683826Lockwasher417401Grease Fitting181********Capscrew,516803075Bearing Seal1926096905Capscrew616098732Drive Group ●208219444Bushing716805545Tube2146806129Spacer816805544Tube2216805447Relief Valve916827506Valve Assembly ■2326816265Seal1017406Grease Fitting242768792Capscrew 1146064636Capscrew2516858787Tube124680253Lockwasher2616858696Tube●S ee Drive page for parts breakdown.★Includes items 1 and 20-21.■S ee Valve page for parts breakdown.Reference: F astener Kit 6810595-R2♦Includes seals 6816257-includes item 23/Umfasst Dichtungen 6816257/Comprend des joints 6816257.Drive GroupREF QTY PART NO.DESCRIPTION6098732Drive Group (R12) 116098727Housing216098712Cover316098725Motor Flange 426098716Flange Gasket 58761170Capscrew, M6 x 20 63682662Capscrew, M6 x 16 716845226Gasket82678985Bearing916098731Worm1016098728Pinion1116098730Worm Gear 1216038311Key1346059569Capscrew, M6 x 12REF QTY PART NO.DESCRIPTION 142778100Fitting, M16 1516036948Bearing161643369O-Ring1716098720Pinion Seal 1816052850Bearing1916098714Cover203663694Plug, 32116039450Motor2216097882Retaining Ring 2316803094Shim – .127 mm (blue) 2416803095Shim – .254 mm (brown) 2516803096Shim – .381 mm (pink) 2616803097Shim – .508 mm (yellow) 2716069835Relief FittingValve AssemblyREF QTY PART NO.DESCRIPTION6827506Valve Assembly116827508Valve Body u21221722Solenoid Valve Cartridge316031791Service Kit41220627Solenoid Valve Cartridge51221049Service Kit626003173Counterbalance Valve Cartridge 72667516Service Kit82604511Fitting, 6-6926091175Fitting, SAE 6 – 10 mm L-Series 102663694Plug, 31116064346Orifice121220641Orificeu Includes items 10-12.Valve AssemblyREF QTY PART NO.DESCRIPTION6805447Valve Assembly 5 116805407Valve Body22778100Fitting33663694Plug42659058Check Valve 52667516Seal Kit61214405Relief Cartridge 71682170Seal KitHosing GroupPositioned Short ArmOpenCylinder24HREF QTY PART NO.DESCRIPTION6861416Hose Group126806346Hose, 700 mm226806346Hose, 700 mm326806345Hose, 520 mm426806345Hose, 520 mm54673416Segment64200343Cable TieReference: SK-30682.Revolving Connection GroupREF QTY PART NO.DESCRIPTION6823071Revolving Connection Group16820344Revolving Connection Assembly 116823031Valve Body216823058Shaft316821410End Block413138 R etaining Ring517341 R etaining Ring63214649 S haft Seal78777913Fitting, 4-482604511Fitting, 6-692684587 O-RingIncludes items 1 – 15.Included in Service Kit 6026296.REF QTY PART NO.DESCRIPTION 102768797 C apscrew, M8 x 40111220869Check Valve1216025595Seal Kit131214405Crossover Relief Cartridge 141682170Seal Kit1516823039Valve ⏹1626037989Support1746038809Capscrew, M10 x 201816836429Plate192783608Capscrew, M10 x 166026296Service Kit⏹See Valve page for parts breakdown.18HValve AssemblyREF QTY PART NO.DESCRIPTION6823039Valve Assembly 116823040Valve Body 246405512Capscrew, M6 x 100 34206323Lockwasher, M64 526043425Relief Valve Cartridge 16024293Flow Divider CartridgeREF QTY PART NO.DESCRIPTION6807259Cylinder Assembly 116805856Shell216804993Rod Assembly 326802703Bushing416084094u Wear Ring 516084070u Seal 616800393Piston 716084135u O-Ring 816808315u Dual Seal 916802703Bushing H 101221866u Sealu Included in Service Kit 6804211.HIncluded in Rod Assembly.REF QTY PART NO.DESCRIPTION1116800403Retainer 121421356u Wiper1316800463Rod End H1416038929Check Valve – PO 152609234Fitting, 41616803297Fitting, SAE 6 – 14 mm L-Series 171777915Fitting, SAE 6 – 14 mm L-Series 181667516Check Valve Service Kit 191561012Nut2016064310u Seal Loader 6804211Service KitReference: S-24108, S-24193.18H/20HCYLINDER ASSEMBLY PART NUMBERREF QTY PART NO.DESCRIPTION6861379Cylinder Assembly 116861380Shell216861383Rod Assembly 326802703Bushing 416084094 Wear Ring 516084070 Seal 616800393Piston 716084135 O-Ring 816808315 Dual Seal 916802703Bushing 101221866SealIncluded in Service Kit 6804211.Included in Rod Assembly.REF QTY PART NO.DESCRIPTION1116800403Retainer 121421356 Wiper1316800463Rod End1416038929Check Valve – PO152609234Fitting, 41616803297Fitting, SAE 6 – 14 mm L-Series 171777915Fitting, SAE 6 – 14 mm L-Series 181667516Check Valve Service Kit 191561012Nut 2016064310 Seal Loader 6804211Service KitReference: S-24108, S-24193.18H/20HCYLINDER ASSEMBLY PART NUMBERREF QTY PART NO.DESCRIPTION6857844Short Arm Group 116857845Short Arm226816313Pin326816307Pin426816312Pin5126089559Capscrew, M10 x 20646803802Retainer726806146Retainer866803315Dowel Pin94674837Shim1086821872Shim1146081766Pad Spring 126766496Capscrew, M6 x 12 1346071414Spring1426098978Spring Anchor 1516097843Tip Repair Kit Reference: SK-30165REF QTY PART NO.DESCRIPTION6857850Long Arm Group 116861363Long Arm, Split LH216861362Long Arm, Split RH326816313Pin426816307Pin526816312Pin6126089559Capscrew, M10 x 20746803802Retainer826806146Retainer966803315Dowel Pin104660200Shim1186821872Shim1246081766Pad Spring136766496Capscrew, M6 x 12 1446071414Spring1526098978Spring Anchor 1616814103Tip Repair Kit Reference: SK-30170Contact Pad Group – Short ArmREF QTY PART NO.DESCRIPTION6814366Contact Pad Group – Short Arm R1 126814367Contact Pad, RXH226814212Pin346823345Roll Pin426070669Link526821649Clevis Pin626821671Retaining Ring746076106Spring AnchorContact Pad Group – Long ArmREF QTY PART NO.DESCRIPTION6814294Contact Pad Group – Long Arm R1 126814295Contact Pad, RXH226814212Pin346823345Drive Pin426070669Link526821649Clevis Pin626821671Retaining Ring746076106Spring AnchorMounting GroupClass II, 0°REF QTY PART NO.DESCRIPTION6830843Mounting Group 126818731Upper Hook 210211128Capscrew, M16 x 30 31212999Center Key41669344Stop Block Kit 52675514Lower Hook62675515Guide72678832Pin846812734Capscrew, M16 x 35Rotational Control AssemblyRotational Control Assembly(NOT UL CLASSIFIED)Common ComponentsREF QTY PART NO.DESCRIPTION62768784Capscrew, M5 x 3571222256Switch/ Cable Assembly 81222024Switch/ Cable Assembly 91222021Switch Mounting Bracket 1026002668Capscrew, M8 x 20111222021Switch Mounting Plate 1226002501Cable Tie Anchor 1376002451Cable Tie Anchor 1496002479Cable Tie158761170Capscrew, M6 x 20161222023Power Cable172228720Extension Cable Assembly 1836009228Shim, .030 in.1916812325Casting, ERC Ramp 206202346Washer216206323Lockwasher2216048222Switch Assembly2316001641Shrink Tubing. 25 mm dia.2416026934Shrink Tubing, 75 mm dia.Reference: Common Components Group 6812663 & 6811471.NON ULREF QTY DESCRIPTION6812696Rotational Control 116811810Wire Harness1—Fuse, 5 Amp, 12V , UL Classified 216806701Fuse, 2 Amp, 24–48V , UL Classified 1219414Fuse, ATC-10 ■316003164Solenoid/Cable Assembly 416003172Solenoid/Cable Assembly 51227894Relay Enclosure Assembly■Use with non UL Classified kits (older versions)48V PART NO.Do you have questions you need answered right now? Call your nearest Cascade Parts Department.Visit us online at AMERICASCascade CorporationParts Sales2501 Sheridan Ave. Springfield, OH 45505Tel: 888-CASCADE (227-2233) Fax: 888-329-0234Cascade Canada Inc.5570 Timberlea Blvd.Mississauga, OntarioCanada L4W-4M6Tel: 905-629-7777Fax: 905-629-7785Cascade do BrasilRua João Guerra, 134Macuco, Santos - SPBrasil 11015-130Tel: 55-13-2105-8800Fax: 55-13-2105-8899EUROPE-AFRICACascade Italia S.R.L. European Headquarters Via Dell’Artigianato 137030 Vago di Lavagno (VR) ItalyTel: 39-045-8989111Fax: 39-045-8989160Cascade (Africa) Pty. Ltd. PO Box 625, Isando 1600 60A Steel Road Sparton, Kempton Park South AfricaTel: 27-11-975-9240 Fax: 27-11-394-1147ASIA-PACIFICCascade Japan Ltd. 2-23, 2-Chome, Kukuchi Nishimachi Amagasaki, Hyogo Japan, 661-0978 Tel: 81-6-6420-9771 Fax: 81-6-6420-9777Cascade Korea121B 9L Namdong Ind.Complex, 691-8 Gojan-DongNamdong-KuInchon, KoreaTel: +82-32-821-2051Fax: +82-32-821-2055Cascade-XiamenNo. 668 Yangguang Rd.Xinyang Industrial ZoneHaicang, Xiamen CityFujian ProvinceP.R. China 361026Tel: 86-592-651-2500Fax: 86-592-651-2571Cascade India MaterialHandling Private LimitedNo 34, Global Trade Centre1/1 Rambaugh ColonyLal Bahadur Shastri Road,Navi Peth, Pune 411 030(Maharashtra) IndiaPhone: +91 020 2432 5490Fax: +91 020 2433 0881Cascade Australia Pty. Ltd. 1445 Ipswich Road Rocklea, QLD 4107 AustraliaTel: 1-800-227-223Fax: +61 7 3373-7333Cascade New Zealand15 Ra Ora DriveEast Tamaki, AucklandNew ZealandTel: +64-9-273-9136Fax: +64-9-273-9137Sunstream IndustriesPte. Ltd.18 Tuas South Street 5Singapore 637796Tel: +65-6795-7555Fax: +65-6863-1368cCascade Corporation 2013 3-2013。
LANDesk产品手册2010目录一. 桌面管理中遇到的问题 (1)1 桌面为什么需要管理 (1)2 桌面如何管理 (1)二.LANDesk解决方案介绍 (3)1 LANDesk公司简介 (3)2 LANDesk产品列表 (3)3 LANDesk解决方案功能及卖点 (5)3.1 管理解决方案产品简介 (5)资产管理 (5)远程支持 (7)软件分发 (8)软件授权监视 (10)操作系统分发和配置迁移 (11)LANDesk应用程序虚拟器(插件) (14)3.2 安全解决方案产品简介 (16)LANDesk补丁管理器(插件) (16)防病毒软件病毒代码管理 (19)桌面防火墙管理 (19)安全威胁分析 (20)蓝代斯克更新 (20)软件禁用 (20)间谍软件检测和排除 (21)设备外设控制 (21)LANDesk主机入侵防护系统(插件) (22)客户端安全准入 (23)LANDesk 防病毒软件(插件) (24)4 LANDesk管理方案特点 (26)三. LANDesk解决方案案例(部分) (28)附录1 产品价格表 (28)附录2 产品架构 (30)单一服务器部署架构 (30)网络拓扑图 (30)节点说明 (30)管理模式介绍 (31)管理角色划分 (31)系统维护 (32)系统安全 (33)附录3 软件分发技术 (34)有目标的多址广播 (34)对等下载 (36)字节级的断点续传技术 (37)动态带宽调整技术 (37)一.桌面管理中遇到的问题1桌面为什么需要管理现在,随着企业IT应用的不断深入和普及,拥有数百台甚至成千上万台个人电脑、服务器和移动设备的企业越来越多。
如何对它们进行高效率的管理?这已成为令CIO们头痛的事情。
比如,当微软发布了一个新的Windows补丁程序时,如果是有30~40台PC的企业,网管员可以逐一去打补丁,但如果一个公司有1000多台电脑,IT管理人员却非常有限,而且还有外地的分支机构,怎么办?而且这些电脑运行着各种前端企业应用,其稳定性、可靠性、安全性及性能不仅直接影响员工的工作效率,也对整个企业的业务效率和管理成本有着重要影响。
与此同时,由于个人电脑和移动设备的使用自主性大,桌面的内容和应用往往因人而异,不按要求及时升级安全补丁软件、安装未经授权的软件都可能导致桌面端设备和移动设备成为企业IT管理“木桶效应”中的“最短木块”。
对桌面设备、服务器和移动设备管理程度的高低直接决定着IT设备的应用效能和企业整体IT系统成本的控制。
据Gartner对IT系统成本分析报告,在整个企业的IT系统成本中,由于终端用户操作不当而带来的成本增加已高达48.7%。
而这些成本往往都是计划外的支出。
因此,企业级用户的桌面管理已成为一个重要的IT管理问题。
2桌面如何管理何为桌面管理?简单地说,桌面管理就对企业IT系统中的桌面设备进行全面的管理,保证企业IT系统稳定、安全、可靠地运行。
我们先来看一下,一台设备从采购到淘汰需要经过怎样的使用生命周期呢?用户在采购设备之后,首先要登记设备的硬件配置,然后安装并配置操作系统;安装应用软件、配置应用环境,一切OK之后,设备进入使用阶段,需要进行日常维护,解决可能出现的问题;实施必须的管理策略,跟踪用户应用的使用情况;统计设备从硬件到软件的IT资产并形成报告;保障设备系统和应用的安全性;升级设备的硬件和软件环境。
对这个使用生命周期的每一过程进行管理,就是桌面管理所需要涉及的内容。
一般来说,桌面管理涵盖的范围包括IT资产的统计和追踪、软件和操作系统的安装、日常维护、安全监控和管理、应用监控和服务器管理等。
IT资产的统计和追踪“企业到底有多少IT资产?这些资产的实时状态如何?”这是企业IT管理的基础问题。
企业不仅需要了解系统硬件构建的IT资产信息,而且还要包括安装的操作系统和应用名称、版本以及系统的配置信息,比如机器名、用户、IP地址等,这些资产信息都是随时更新的。
软件和操作系统的安装在企业新购设备,或在操作系统崩溃后,第一件要做的事就是安装或恢复操作系统和应用,如果只能在设备本地逐台操作,显然费时费力。
企业需要对网络中客户端的操作系统和应用程序进行统一的安装和配置,提高管理效率,更赢得宝贵的时间。
日常维护很多IT管理员往往疲于应对电话求助和现场服务,工作效率非常低,而且大部分是重复性的简单劳动。
企业需要IT管理员能够远程解决问题,只有在特殊情况下才到现场支持,从而大幅度提高支持效率。
安全监控和管理安全漏洞、恶性病毒、黑客攻击等事件常常给企业来严重的灾难。
企业需要能够统一掌握终端设备的漏洞状况,了解网络终端的平台安全性,包括用户的共享安全性、密码安全性、IE安全性等,并能统一应用安全补丁,实施安全策略并及时反馈效果。
应用监控一些终端用户安装一些业务无关的应用程序,比如聊天工具、游戏等,这些应用的使用不仅影响员工的工作效率,更影响网络的性能。
企业需要实时地对用户的应用使用情况进行详细的跟踪并严格限定某些无关应用的使用。
服务器管理现在,企业中的PC服务器数量逐渐增加,但对服务器的维护和管理主要还是通过每天定时的人工监视和用户的问题反馈来实施。
企业需要对服务器的关键硬件和操作系统资源进行实时监控,当出现安全、功能或性能问题时实时报警、响应并记录日志。
以上的管理工作仅靠简单的手工维护方式已经无法胜任,企业需要更好的桌面和设备管理工具,在IT系统生命周期的每个环节中,掌握IT系统资产信息和监控应用系统的应用效率、可靠性和可扩展性,帮助企业维持稳定的业务和收益,在不添置额外软硬件设备的情况下,最大限度地提升IT架构的应用价值和安全保障。
二. LANDesk解决方案介绍1LANDesk公司简介LANDesk软件公司是业界领先的桌面设备,服务器和移动设备的管理和安全解决方案提供商。
自2002年从Intel拆分出来后,保持了50%以上的高速增长。
其产品线以LANDesk管理套件为核心,扩展了补丁管理器、桌面安全管理套件、系统管理器、服务器管理器、手持设备管理器等多个产品和插件。
在企业网络终端设备的管理和安全防护领域提供了全面的解决方案。
在2006年4月27日,蓝代斯克与美国Avocent公司签署最终协议,Avocent 收购蓝代斯克软件公司。
蓝代斯克将成为Avocent的独立业务部门,充分利用双方合并后在硬软件方面的协力优势,提供业界唯一的“不间断”管理解决方案,蓝代斯克与Avocent联合起来,将能够提供一系列完整的管理解决方案,它们具有无与伦比的端到端应用范围、适用于从数据中心直到终端节点的各个领域。
LANDesk中国分公司于2003年初在北京建立,现在在上海,广州,香港、台北有办事机构。
到目前为止已经发展成为具有研发,测试,销售,市场等完整架构的营运中心,员工共160多人,可以为国内市场的用户提供即时高效的服务和支持。
到目前为止,在银行,电信,移动,联通,交通,石化,传媒、政府等领域拥有众多的用户。
2LANDesk产品列表3LANDesk解决方案功能及卖点我们希望通过使用蓝代斯克产品帮助客户对其桌面系统的整个IT生命周期进行管理,包括设备的购置、安装、日常维护、管理、系统升级、迁移到报废的完整过程;另外通过我们的产品实现对桌面系统日常使用中的安全管理,包括持续更新补丁、间谍软件防护、杀毒软件管理、防火墙管理等等。
3.1 管理解决方案产品简介在现代企业环境下,一个IT的管理部门需要花费大量的人力物力来维护企业的计算机运行环境。
同时,由于计算机设备的更新和变化,财务部门对企业的计算机设备的管理和统计经常处于一种无序及手工统计的状态,当设备更新频繁时,原本的设备管理记录往往由于管理的滞后和对实际情况的掌握程度不够无法及时更新,从而造成设备管理的混乱还会造成时间的迟滞,影响企业的运行效率,给企业带来损失。
如何解决这些痛苦的管理问题?您需要一套高效和易于使用的桌面管理解决方案。
LANDesk管理套件通过以下功能模块实现IT资产全生命周期的管理:资产管理远程支持Q:可以对哪些平台进行远程支持?A:Windows , Mac , Linux。
Q:对慢速网络的客户端怎样进行远程支持?A:远程支持可以根据连接的网络进行调节,支持局域网、宽带甚至拨号。
对于慢速网络,远程支持功能会自动挂起客户端的桌面图片仅使用蓝色的桌面。
并且会通过降低截屏的帧数,减少传输的色彩信息等等,减少传输的数据,保证远程支持的响应速度。
Q:远程支持的安全性怎么保证?A:1、管理员如果要对某台设备进行远程支持需要核心服务器来建立连接,核心服务器会验证登录的管理员的口令是否正确,要管理的客户端是否属于该管理员的管理范围;2、核心服务器发送远程支持指令调用客户端的相关代理,客户端通过证书验证核心服务器发来的指令,如果验证通过则客户端打开代理接受管理员的管理;3、管理员使用的控制台和客户端的远程支持代理根据会话密钥建立连接,开始进行远程支持。
控制台和被控制的客户端直接传输的数据和指令全都通过SSL加密。
4、远程支持技术后,控制台和被控制的客户端之间的连接中断,本次会话密钥作废。
5、建立远程支持连接、传送指令、远程执行等操作,核心服务器都会留下日志记录。
软件分发软件授权监视Q:统计许可证数量,是否区分正版盗版?A:由客户端代理扫描客户端机器上安装的应用程序,只要发现应用程序的特征文件就算是一个安装,不论是正版还是盗版。
而且对于很多企业版软件,安装介质都是相同的,序列号或者注册码也是相同的,只是许可证协议上有安装节点数的规定。
规定数量内的安装就是正版,超过规定数量的安装就是盗版,就有可能被罚款。
使用蓝代斯克管理套件提供许可证监控功能,通过客户端代理核心服务器可以收集客户端上所有安装的软件的列表,统计安装的总数量。
Q:绿色软件能否被发现?A:默认情况下,客户端代理只扫描注册表中的软件安装信息,也就是“添加删除程序”中显示的信息,绿色软件因为不需要安装就可以直接运行所以在注册表中没有记录。
如果采用扩展扫描,则客户端代理可以扫描机器上所有EXE文件的信息。
绿色软件也能被发现和跟踪。
Q:许可证信息是哪里来的?A:由管理员人工输入许可证信息,包括数量、序列号、购买日期、金额等信息。
蓝代斯克提供的是第三方的桌面管理工具,收集的许可证信息仅提供给客户自己使用,绝对不会向外发送,造成泄密。
Q:对离线设备怎样监视软件使用情况?A:客户端代理程序会始终跟踪监视软件的使用情况,并将记录结果存在客户端注册表中,当离线设备重新接入网络时,软件使用情况的数据会随同清单扫描数据一起上传的核心服务器,则离线时软件的使用情况数据也可以传送到核心服务器上。
Q:软件改名之后是否还可以禁用?A:可以。
禁用的软件列表不仅包括软件的文件名,还包括该文件的属性,文件头等信息。