横河DLM3000混合信号示波器
- 格式:pdf
- 大小:2.80 MB
- 文档页数:16
横河CS3000功能块说明<Toc> <Ind> <D1. Regulatory Control> D1-1IM 33S01B30-01ED1. Regulatory Control调整控制The regulatory control performs control computation processing using analog process values for process monitor and process control. The function blocks that provide the regulatory control function are referred as “regulatory control blocks.”调整控制是利用过程监控及过程控制中的模拟过程量来进行控制计算处理的。
This chapter presents a detailed description of the function of each of the regulatory control blocks, excluding the Foundation Fieldbus faceplate block. 这章将逐个介绍每个调整控制块的功能,包括基金会现场总线的面板功能块。
SEE ALSO参阅For details on the Foundation Fieldbus faceplate blocks, see chapter A2, “Overview of FF Faceplate Blocks” in the Foundation Fieldbus Reference (IM33Y05P10-01E).想了解基金会现场总线面板功能块的详细情况,请参照关于FF部分的A2章节“FF面板功能块的概述”■Regulatory Control Positioning ¡调整控制的配置The regulatory control is one of the basic controls in the FCS and performs control computation processing to monitor and control processes. The function blocks that perform the this regulatory control are referred as “regulatory control blocks.”调整控制是FCS的一个基本控制单元,执行过程监控的控制计算处理。
精确控制快速灵活DLM2000系列混合信号示波器DLM2000系列12357648910精确控制方便操作的立式设计DLM2000系列示波器的大屏幕显示器位于仪器操作面板的上方。
这种立式机身设计,既可以使显示器与用户视线齐平,又可以节省桌面或测试台的空间。
操作面板布局直观,通道和功能的操作状态一目了然,可以迅速展开所需测量。
方便设置的8.4英寸显示器可以自动或手动分别显示各独立通道的波形,同时保持充分的分辨率和动态范围。
这样无论使用多少通道,都可以轻松查看所有信号的细节。
12345678910水平轴位置/量程旋钮缩放专用旋钮四方向选择按键可上/下/左/右四方向移动光标旋转飞梭逻辑输入接口触发控制键及触发电平旋钮垂直轴位置/量程旋钮紧凑机身搭载大屏幕液晶显示器可在屏幕保留波形迹线的快照键图形化在线帮助按键:内含操作手册3通道模拟 + 8位逻辑ScopeCORE 内部处理器快速灵活灵活MSO 输入捕捉模拟和更多数字信号的混合信号。
只需按下一个按钮,DLM2000就可将通道4转换为8通道数字输入,从而成为一台混合信号示波器。
这不仅可以同时观测3通道模拟+8通道数字信号以及更多的控制信号、逻辑信号,还可以将数字通道用于分析I 2C 、SPI 及UART 串行总线,使模拟通道可用于其他信号的测量。
ScopeCORE 高速数据处理DLM2000采用硬件优化结构和横河专有ScopeCORE 高速数据处理IC ,可执行实时测量与信号处理。
这意味着即使打开很多通道,也不会影响波形采集速率,从而为高速测量提供保障。
DLM2000系列异常信号历史存储与高速采集可捕捉和回放多达50,000屏历史波形通过历史存储功能,DLM2000系列可以捕捉或回放多达50,000屏历史波形。
显示方式既可以选择单屏,也可以选择全部。
使用搜索和测量功能,能快速分离出异常信号并对其进行分析及准确归类,免去使用触发捕捉偶发事件的麻烦。
DLM2000系列的最大连续波形更新率是每秒20,000屏波形,在N 单次模式下则达到450,000屏波形。
Precise control and flexibilityDLM2000系列混合信号示波器12357648910方便操作的立式设计DLM2000的大屏幕显示器位于仪器操作面板的上方。
这种立式机身设计,既可以使显示器与用户视线齐平,又可以节省桌面或测试台的空间。
操作面板布局直观,通道和功能的操作状态一目了然,可以迅速展开所需测量。
方便设置的8.4英寸显示器可以自动或手动分别显示各独立通道的波形,同时保持充分的分辨率和动态范围。
这样无论使用多少通道,都可以轻松查看所有信号的细节。
精确控制1 水平轴位置/量程旋钮2 缩放专用旋钮3四方向选择按键可上/下/左/右四方向移动光标4 旋转飞梭5 逻辑输入接口6 触发控制键及触发电平旋钮7 垂直轴位置/量程旋钮8 紧凑机身搭载大屏幕液晶显示器 9 可在屏幕保留波形迹线的快照键10图形化在线帮助按键内含操作手册灵活MSO 输入捕捉模拟和更多数字信号的混合信号。
只需按下一个按钮,DLM2000就可将通道4转换为8通道数字输入,从而成为一台混合信号示波器。
这不仅可以同时观测3通道模拟+8通道数字信号以及更多的控制信号、逻辑信号,还可以将数字通道用于分析I 2C 、SPI 及UART 串行总线,使模拟通道可用于其他信号的测量。
ScopeCORE 高速数据处理DLM2000采用硬件优化结构和横河专有ScopeCORE 高速数据处理IC ,可执行实时测量与信号处理。
这意味着即使打开很多通道,也不会影响波形采集速率,从而为高速测量提供保障。
DLM2000系列产品3通道模拟 + 8位逻辑ScopeCORE 内部处理器历史波形异常信号超大采集内存最大250M 点超大采集内存成就两大优势,既可执行长时间捕捉,又可保持高速采样率。
因此,所有基于时间设置的测量带宽变得更加有效。
在单次触发模式下,通过增加最大内存选件(/M3)可以对10kHz 信号持续捕捉1小时以上。
即使采样率为1.25GS/s ,相同内存条件也可以捕捉200ms 信号。
Agilent DSOX3000 FE演示指南基本介绍和设置目的和说明这个演示指南主要为分销工程师设计,目标是能独立的为客户做10-20分钟演示,把DSOX3000的一些独特的特点、优势和好处介绍给客户。
需要的设备DSOX3000示波器,两根无源探头N28XXA/B.任务一:示波器基本介绍介绍3000X的一些基本概况.包括:1.5合1设备,即是一台综合示波器,逻辑分析仪,协议分析仪,任意波形发生器,电压表和频率计为一体的综合性设备.根据客户应用情况,针对5合1中的子设备功能做重点介绍。
要点:示波器主要型号,带宽,主要采样率指标,带宽可升级,波形捕获率,强大的触发功能等;MSO的基本指标,采样率,存储深度;协议分析仪支持的串行总线种类,硬件协议触发和解码;任意波形发生器,支持的信号类型和最高频率;电压表和频率计的基本指标。
2.对产品的简洁外形做一简单介绍.3. 针对每个子设备功能能熟练的做自动演示。
任务二:100万次/秒的波形捕获率,信号捕获和触发介绍简介中低端示波器日常主要应用为通用信号调试和观察,因此如何演示3000X的调试和捕获功能无疑是非常重要的.此任务演示主要和TEK DPO3000/4000演示对应,需要展示出3000X在调试能力方面全面超越DPO3000/4000的特点.首先请按自动演示介绍DSOX3000 100万次/秒波形捕获率及与其它竞争对手产品指标差异及对比效果。
其次,采用内部信号做模拟实测演示。
设置步骤:1.连接通道1到Demo1端子和地,通道2到Demo2端子和地。
2.按下Default Setup.按下Help,然后按下培训信号软键,旋转多功能旋钮选择带偶发毛刺的时钟信号,按下右下角输出按钮。
可以看到如下波形:3.调节垂直和水平档位及触发到500mV/Div,20ns/Div,边沿触发在1V/Div,得到如下波形:这时可以看到偶发毛刺信号在闪烁,并强调DSOX3000 业界领先的100万次/秒的波形捕获率可以最快看到这一偶发信号。
横河新品混合信号示波器DLM5000的相关介绍!横河示波器一直以设计精巧,质量稳定著称,深受广大用户喜爱。
早在2002年,横河就推出了世界第一台8ch示波器;2012年,推出了DLM4000系列8ch示波器,当时还是世界上唯一的8ch示波器;如今横河继续保持先行者的勇气,经过细心打磨,今年推出了全新的DLM5000系列示波器。
下面是这款新品的相关介绍!更多灵活通道1、8路模拟通道多至32 bit逻i输入、2、2台同步功能“DLMsync”灵活配置通道数3、引进4通道机型,可以实现“8+8=16”,“8+4=12”, “4+4=8”更直观,更顺畅的操作性1、除旋钮与按钮外,新追加采用了触摸屏操作,更加直观2、USB 3.0接口实现高速传输至PC以进一步分析测量性能1、350MHz/500MHz带宽,2.5GS/s2、最大500 Mpoints长存储3、整体性能改善,如低残留噪声,更准确的触发。
其它性能,提高测量效率1、梳理横河原有的“历史功能”、串行总线分析“串行总线自动设置”、“实时带宽滤波器”、“周期参数测量”、灵活的“用户自定义计算”等独特功能。
2、专用操作系统,启动时间短,稳定可靠。
4、占地面积小。
轻巧便携。
前面板外观及触摸屏基于DLM4000的触摸屏,改善了操控性和其他性能。
屏幕升级为大尺寸触摸屏,操作更加方便。
时间轴,量程与缩放可像平板手机电脑一样,两根手指开合控制。
缩放窗口的位置与光标也可以用手指直接进行拖曳。
测量项目文件名等对话框,可以直接用手指点选,非常方便。
菜单与对话框透明显示(透视)功能,在设置条件的同时也能够查看测量的波形现状。
打开运算通道时,会出现一个运算通道设置按钮,无需复杂菜单操作,直接点选即可对运算通道进行设置。
这两个都是全新的功能。
触摸屏操作●直观的波形操作- Time/div 手指捏合/扩开实现- V/div, 垂直位置, V-缩放与位置-光标与缩放位置可拖曳-缩放比例也可手指捏合/扩开实现-触发电平/ 触发位置可拖曳●设置操作更简单-菜单选择/测量项目选择/文件名输入/对话框条件设置-菜单和设置对话框透明显示功能■设置的同时可以查看测量波形-运算通道的快捷设置■当打开运算通道时,专用按钮就会出现,你可以直接点击它进入设置菜单。
目录1.测试回路连接 (2)2.数值模式 (4)2.1.电流/电压量程和模式的选择 (4)2.2.测试回路模式WIRING、公式的设置 (4)2.3.测试项目ITEM的设置 (5)2.4.U/I的谐波界面显示 (5)2.4.1谐波的项目设置 (6)2.4.2谐波的PLL源和谐波次数的设置 (6)波形设置 (6)3.波形模式 (7)3.1测试项目设置 (7)3.2采样频率设置 (8)3.数值模式和波形模式 (8)4. 转速、扭矩信号的设置 (8)5.屏幕保存(JPEG格式) (9)6.WT Viewer软件监控 (9)6.1软件安装准备 (9)6.2软件设置步骤 (9)1.测试回路连接步骤1:单元1的电压通道(上端)与驱动器直流母线(+/-)连接(并联回路)注1:+/-极性步骤2:单元1电流通道(下端)与驱动器直流母线(+/-)连接(串联回路)注1:+/-极性步骤3:单元2/3电压通道(上端)与被测电机动力线的连接(并联回路)步骤4:单元2/3电流通道(下端)与被测电机动力线的连接(串联回路)注1: 电流方向:传感器上箭头指向被测电机动力端。
2.数值模式图示:Numeric 数值模式2.1.电流/电压量程和模式的选择2.2.测试回路模式WIRING 、公式的设置234522.3.测试项目ITEM 的设置2.4.U/I 的谐波界面显示32 1 3:single i tem 谐波显示界面 4:Dual i tem 谐波显示界面2.4.1谐波的项目设置2.4.2谐波的PLL 源和谐波次数的设置波形设置1:谐波显示界面21:谐波显示界面23.波形模式3.1测试项目设置1233.2采样频率设置3.数值模式和波形模式4. 转速、扭矩信号的设置15.屏幕保存(JPEG 格式)USB 盘插入→按键IMAGE SAVE注:屏幕左上角显示磁盘图标,显示保存中,不可拔除USB 盘6.WT Viewer 软件监控6.1软件安装准备默认安装“GPIB_driver ”GPIB 硬件驱动 和“WTViewer ”监控软件6.2软件设置步骤步骤1. WT3000设备开启 步骤2. WT Viewer 软件开启步骤3. 选择off-line 通讯模式并确认OK (见下图3)图表 2传输单元:GPIB 数据 图表 1:WT Viewer 软件 图表 3步骤4. 选择功率计型号WT3000并确认OK. (见下图4)步骤5.选择测试模式normal Mode 并确认OK. (见下图5) 、图表 5步骤6. 进入off-line 模式下的软件界面(见下图6)步骤7. 设置测试项目数和项目字体大小图表 4图表 6 1 32步骤8. 功率计WT3000上设置相关ITEM 项目(U/I/P 等)步骤9. 连接WT3000背部GPIB 的数据通讯线到PC 的USB 口步骤9. 软件下拉式菜单Communications/communications mode选择on-line步骤10. 选择GPIB 界面步骤11. GPIB 地址:勾选1步骤12. 再次选择on-line模式下的Normal mode步骤13.进入Online模式下的软件界面(WT3000本体进入Remote mode)步骤14. 设置CSV文件存放步骤15. 取消fast mode和auto naming的勾选步骤16. 点击界面中的项目变更设置步骤17. 点击软件中的积算start和stop步骤18. 点击软件中的数据下载start和stop注1:START :软件开始自动采样数据注2:STOP :软件技术采样数据步骤19. CSV格式数据保存。
HMO3000 SeriesMixed Signal Oscilloscopes 300/400/500 MHz BandwidthT e s t & M e a s u r e m e n tP r o d u c t B r o c h u r e | 01.10Intelligent user interfaceTo optimize the screend isplay the instrument shows and hides menusPrecise signal analysis4 Gsamples/s sampling rate 8 Msamples memorySetupIntuitive, multi-lingual user menuFFTSuperb FFT functionalityHelpContext-sensitive helpQuick viewAt the push of a button the 16 most important values of the measured signal are permanently updated and displayedFanMaximum noise reduction by temperature-controlled fanZoomMemory zoom up to 250,000 : 1Analog channelsVertical sensitivity of up to 1 mV/div.Bus signal sourceTo create SPI, I 2C, UART and counter signalsAlways with MSO functionalityAnalyze analog channels plus up to an additional 16 digital channelsMathWide range of programmable math functionsSerial Bus AnalysisHardware-based triggering and decoding (optional)2 HMO3000 SERIES2014Product of the YearHMO3000Winner in category Test & MeasurementAt a glanceThe 2- and 4-channel instruments provide bandwidths of 300, 400 and 500 MHz, a sampling rate of 4 GSa/s and a memory depth of 8 MPts. The instrumentsare rounded off with a standard inclusion of the MSO functionality and several options for serial bus analysis to meet all requirements of modern development designs.HAMEG Instruments is offering the new HMO3000 series exclusively as amixed-signal oscilloscope. It is also unnecessary to initially activate the mixed-signal functions via software options, as is the case with other suppliers. The low capacitance logic probes HO3508 (also available as double pack HO3516) are optional. They allow the analysis of up to 16 logic channels with a sampling rate of 1 GSa/s. HAMEG logic probes are not linked to a specific instrument serial number. This allows their use with all digital HAMEG oscilloscope of the HMO series.For communications between embedded systems and the environment the HMO3000 includes hardware-based signal triggering and decoding for all common protocols (I2C, SPI, UART, CAN and LIN). This option can be activated with an upgrade voucher at any time.The integrated three-digit digital voltmeter enables service technicians to simultaneously perform voltage measurements on all analog channels with four values totalling. The segmented memory option HOO14 enables you to divide the available memory of your HMO3000 into up to 1000 segments. This procedure allows sampling rates of 200,000 Wfm/s, which makes it possible to capture rare anomalies occurring during many short events in quick succession. For the analysis of the recorded signals, all measurement functions of the HMO are available, including the Pass/Fail function.Thanks to the FFT analysis function with 64 K test points the HMO3000 series keeps pace with significantly larger oscilloscopes also in the frequency domain. The time domain signal, measurement window, FFT analysis result are displayed together on a single screen, which makes it easier to evaluate the input waveform.The HMO3000 series offers time domain, logic, protocol and frequency analysis in a single instrument and is a member of the Rohde & Schwarz family of scope-of-the-art oscilloscopes.Systems that are constantly becoming faster and more complex lead to everhigher demands on the required measurement technology. The new HAMEGoscilloscope series HMO3000 offers the solution for current requirements inregards to bandwidth, sampling rate and memory depth. Its bandwidth of upto 500MHz allows HAMEG Instruments to set a new milestone in the develop-ment of high-performance mixed-signal oscilloscopes at an attractive price.More information | 3500 MHz400 MHz 300 MHz 4 channel HMO3054HMO3044HMO30342 channelHMO3052HMO3042HMO30324 HMO3000 SERIESKey factsSuperior hardware-based acquisition for precise measurement results ❙4 Gsample/s sampling rate, 8 Msample memory depth ❙High vertical sensitivity down to 1 mV/div❙Low-noise measurement due to state-of-the-art A/D converter ❙High acquisition rate to identify signal faults❙Segmented memory and manually adjustable memory depthVersatile measurement functions and fast results ❙Wide selection of automatic measurement functions ❙QuickView: key results at the push of a button❙Mask test: a new mask can be easily created with just a few keystrokes ❙FFT: the easy way to analyze the signal spectrum Logic analysis with the MSO option ❙Mixed signal function as standard ❙Precise triggering on signal events❙Straightforward display of digital signals❙Low test point loading due to active probe solutionSerial bus analysis: hardware-based triggering and decoding ❙Versatile trigger options for isolating specific data packets ❙Color-coded display of decoded bus signals❙Direct export of analyzed data to USB memory drive ❙Simultaneous decoding of two buses in realtimeVoltmeter measurements using an oscilloscope ❙Three-digit display for precise voltage measurements❙Simultaneous measurement on all analog channels of up to four voltage values totalling Future-ready investment and scalability ❙Free firmware updates❙Bandwidth upgrades as required❙Serial bus analysis and segmented memory via optional software licensesMore information | 5300 MHz, 400 MHz, 500 MHzShould your requirements change, then so does the HMO3000, as the 300 MHz models can be extended to 400 MHz and 500 MHz bandwidth via software upgrades whenever required. This is done with option upgrade vouchers available at your dealer.❙For 300 MHz to 400 MHz: HV342 (2 channel) and HV344 (4 channel) ❙For 300 MHz to 500 MHz: HV352 (2 channel) and HV354 (4 channel) ❙For 400 MHz to 500 MHz: HV452 (2 channel) and HV454 (4 channel)Vouchers for bandwidth upgrades or serial bus analysis options are available at your dealer.The individual voucher number and the serial number of the instrument to be upgraded is entered at . The customer immediately receives the respective licence key which can be loaded via USB memory drive into the instrument.Always a MSOno software option being necessary to unlock it.6 HMO3000 SERIESMore information | 7 ❙Logic probe HO3508 fits to all HMO series oscilloscopesHAMEG is offering the new HMO3000 series exclusively as a mixed-signal oscilloscope. The great advantages of these instruments are best illustrated by taking a look at how ADCs (Analog Digital Converter) or DACs (Digital Analog Converter) are integrated.These transformer modules include an analog signal on the one side and a digital signal on the other side. As shown in the image below the latency time of a DAC can be determined with one simple cursor measurement. Therefore a MSO allows developers to devote their full attention to the circuit without having to waste energy on the measurement setup.The active logic probe HO3508 (also available as double pack HO3516) is available separately and is not linked to a specific serial number of an instrument. It can be used with any HMO oscilloscope.14 bit DAC signal change8 HMO3000 SERIESSerial Bus AnalysisI 2C, SPI, CAN or LIN – in terms of interaction with the outside world for embedded systems, it is safe to say that these are the most commonly used communication protocols. The new HMO3000 series by HAMEG Instruments offers you hardware-accelerated signal triggering and decoding for all of these protocols. You can upgrade your instrument via software licence keys with those functions required to develop your application:❙HOO10/HV110: Analysis of I 2C, SPI and UART/RS-232 signals on analog and logic channels ❙HOO11/HV111: Analysis of I 2C, SPI and UART/RS-232 signals on all analog channels ❙HOO12/HV112: Analysis of CAN and LIN signals on analog and logic channelsSerial bus trigger types:❙I 2C: Start, Stop, ACK, nACK, Address/Data❙SPI: Start, End, Serial Pattern (32Bit) ❙UART/RS-232: Startbit, Frame Start, Symbol, Pattern❙LIN: Frame Start, Wake Up, Identifier, Data, Error❙CAN: Frame Start, Frame End, Identifier, Data, ErrorSPI bus signal, MISO / MOSI decodedHEX decoded CAN bus signalI 2C bus signal in zoom viewMore information | 9Segmented MemoryThe segmented memory option HOO14 enables you to divide the available acquisition memory of your HMO3000 into up to 1000 segments.This procedure allows sampling rates of 200,000 Wfm/s, which makes it possible to capture rare anomalies occurring during many short events in quick succession. For the analysis of the recorded signals, all measurement functions of the HMO are available, including the Pass/Fail function.You can upgrade to option HOO14 at any time with voucher HV114. The individual voucher number and the serial number of the instrument is entered at .10 HMO3000 SERIESDigital Voltmeter (DVM)The three-digit digital voltmeter is also a standard feature which makes the work of service technicians in particular easier. Voltage measurements can be performed simultaneously for all analog channels. Integrated into a single compact device it allows you to keep your workplace tidy.❙Perform measurements simultaneously on all analog channels, with up to four freely definable parameters totalling❙These options are available: DC, DC rms , AC rms , Crest Factor, V pp , V p+, V p- ❙You decide about the position of the values on the screenDVM on two analog channels with four measurement parametersRamp waveform measured by DVMHZ15 probe (sold separately)Frequency AnalysisDue to the outstanding FFT functionality of the HMO seriesoscilloscopes signals can also be analysed inthe frequency domain with up to 65,536 points. Additional practicaltools such as cursor measurement as well as peak-detect functions arealso available. They allow engineers to complete their analysissignificantly faster, also in the frequency domain.Easy analysis in frequency domainIn the time domain quite often the distortion of input s ignals cannot bedetected with the naked eye. For instance, an acquired sine wave signala ppears to be undistorted. Only the frequency spectrum - available withjust one push of a button - clearly displays additional harmonics thatoccur as harmonic oscillations for multiples of the basic frequency.Since FFT is also active for previously stored signals, it is possible tosubsequently analyze any sections of those signals captured in singleshot mode or stop mode with an adjustable window width.More information | 1112HMO3000 SERIESMore information | 1314 HMO3000 SERIESAccessories included:HO730 Ethernet/USB dual-interface card, Line cord, printed operating m anual, 2/4 probes (amount=number of channels), 10:1 with attenuation ID (HZ350 400/300 MHz, HZ355 500MHz), software-CDRecommended AccessoriesHO720USB-device/RS-232 d ual-interface cardHZ99Carrying case forprotection and transportHZO50AC/DC current probe 30 A, DC to 100 kHzHZ355DUUpgrade from2 x HZ350 to 2 x HZ355HZO51AC/DC current probe 100/1000 A, DC to 20 kHzHO740IEEE-488 (GPIB) interface card, galvanically isolatedHZ4619” rackmount kit, 4 RUHZO20High voltage probe 1000:1 (400 MHz, 1000 V rms )HZO301 GHz active probe (0.9 pF , 1 MΩ)HZ115Differential Probe 100:1/1000:1HZO41Active differential probe 800 MHz (10:1, 1 pF , 200 kΩ)HZO40Active differential probe 200 MHz (10:1, 3.5 pF , 1 MΩ)HO35088 channel logic probe (350 MHz, 4 pF)HAMEG Instruments GmbHIndustriestr. 6 | 63533 Mainhausen | Germany | Phone +49 (0) 6182 8000R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KGHAMEG Instruments® is a registered trademark of HAMEG Instruments GmbHTrade names are trademarks of the ownersPD 3607.0146.32 | Version 01.10 | 09/ 2014 | © HAMEG Instruments GmbHData without tolerance limits is not binding | Subject to change3607014632P D 3 6 0 7 . 0 1 4 6 . 3 2 V 0 1 . 1 0 P D P 1 e n。
横河新一代混合信号示波器DLM3000的产品功能
独有先进功能
在DLM3000系列的多通道混合信号功能中,第四通道模拟输入信号可转换为8位逻辑输入,因此该仪器可用作3通道模拟示波器+8位逻辑分析仪。
这意味着该仪器突破了仅有四个通道的限制,不仅可用于同时观测模拟和数字控制信号,也可用于I2C,SPI或其他串行总线的逻辑输入分析。
DLM3000能支持多达500 M点的采集数据(选件),是DLM2000系列的两倍,也是目前示波器领域的世界之最。
在超长存储技术支持下,DLM3000历史记录功能可以保留多达100,000个波形,可以搜索和比较的波形数量加倍,以提高效率。
改进的性能
通过改进硬件设计,将残留噪声降低了50%,测量灵敏度设置范围提升到500μV,最大直接输入电压至300 Vrms。
这些功能使DLM3000能够在更宽的电压范围内准确地观察信号波形。
在较长时间内对信号进行高速测量会产生大量数据。
DLM3000支持USB3.0标准,因此能将大量数据高速转存至PC。
DLM3000用户界面继承了其他横河公司产品中广受欢迎的许多功能,现在还追加了一个电容式触摸屏,可提供与智能手机相似的直观易用性。
3. 卓越的总线分析功能
为了应对EV和ADAS的开发,DLM3000在原有车载总线触发功能基础上,推出了支持具有灵活数据速率(CAN FD)和CXPI车载LAN标准的CAN。
由于使用触发功能捕获的波形数据和信号分析结果可以显示在同一屏幕上,因此用户可以一目了然地识别这两组数据之间的关系。
总结
DLM3000示波器具有独特的外型设计,强大的测量与分析功能,便捷的人机交互界面,
是追求功能与效率的理想选择。
横河电机发布新型混合信号示波器系列
横河电机发布新型混合信号示波器系列
日本横河电机株式会社近期推出新型混合信号示波器DLM6000系列和新型数字示波器DL6000系列。
新产品不仅秉承了前期在市场上获得一致赞誉的DLM2000系列的全部优势,诸如操作直观、外形紧凑以及灵活的MSO输入等,更能满足1.5GHz带宽以及高达32位的逻辑输入需求。
DLM6000/DL6000系列再次彰显了横河电机示波仪器的一贯优势:高速波形处理能力和快速显示计算分析的波形信息两者兼备、更加人性化的操作以及更加多样化的机型。
DLM6000/DL6000将于DLM2000一起,以真正满足工程师切身需求为目标,在中国波形测试仪器市场上撑起自己的天空。
DLM6000/DL6000将广泛惠及数字消费电子、计算机外围设备、半导体、汽车、发动机/变压器、航空等领域,并享有3年保修期。
主要参数:
模拟带宽500MHz/1GHz/1.5GHz(DL6154)
DLM6000提供4通道模拟+16/32位逻辑
操作直观,X/Y轴位置和触发水平旋钮
快速捕捉、历史记忆存储以及多样的触发功能可以轻易获取目标波形
多样计算和分析功能可以快速分析出波形隐藏的信息
串行总线触发和分析(选件:CAN、LIN、UART、I2C、SPI)。
横河混合信号示波器DLM3000的应用领域
从DLM3000的速度、性能和带宽这些参数,您就会发现它是许多实验室开发和研发工程师的理想选择。
带宽可达200、350或500兆赫兹,每秒2.5G 的采样率,精细到每格500微伏量程的信号分辨率,能够满足您速度和精度的双重要求。
大容量内部固态波形存储器,可存储多达5亿点的波形数据,用户能够更好地捕获并观测波形异常。
混合信号示波器DLM3000 可支持FlexRay、CAN、LIN和SENT等系列车载总线,因此备受受汽车工程师欢迎,它也同样适用于电机控制、消费电子、办公设备和电源的测试。
横河混合信号示波器DLM5000系列
作为世界上第一台8通道示波器的创造者,DLM5000
是YOKOGAWA最新推出的产品
系列,拥有超过100年的行业经验,它将带给您超过8个通道的测量体验。
适应性是高性能智能功率半导体技术和机电一体化技术在现代电动汽车、电机控制和节能电子设计中发展的关键要求。
将高响应的大触摸屏和传统的示波器面板相结合,4到8通道DLM5000混合信号示波器让用户通过指尖触控,即可轻松浏览丰富的分析功能。
简单–有了灵敏的触摸屏,用户可以直观地浏览各种菜单、访问缩放功能、搜索和识别波形中的特定事件,同时仍然可以使用传统的示波器控制面板。
DLM5000是一款紧凑的8通道示波器,非常适合您的实验室和设计环境。
适应性强– DLM5000具有多达8个模拟通道和32位逻辑,以及附加的运算通道、车辆串行总线和其他分析功能,为用户提供了多种类、多通道测量所需的灵活性。
此外,DLMsync支持多单元同步,将测量扩展到16个通道,以适应更多应用场合。
可靠– YOKOGAWA多年来致力于测量品质,DLM5000具有低残余噪声、多电压量程和各种实时低通滤波器,能够确保信号的真实度。
历史记录内存允许用户保存和分析捕获的全部触发波形,确保不会丢失任何数据。
专用的嵌入式操作系统使DLM5000稳定可靠。