P1D系列parker气缸
- 格式:docx
- 大小:498.60 KB
- 文档页数:5
aerospaceclimate control electromechanical filtrationfluid & gas handling hydraulics pneumatics process control sealing & shielding1Safety Information (1)1.1Markings and Symbols (1)2Description (2)2.1Stages of Purification (2)2.2Technical Specification (2)2.2.1Pressure Correction Factors (2)2.3Weights and Dimensions (3)2.4Receiving and Inspecting the Equipment (4)2.4.1Storage (4)2.4.2Unpacking (4)2.4.3Overview of the Equipment (5)3Installation & Commissioning (6)3.1Recommended system layout (6)3.2Locating the Equipment (7)3.2.1Space Requirements (7)3.3Mechanical Installation (7)3.3.1General Requirements (7)3.3.2Securing the Unit (7)4Operating the Equipment (8)4.1Starting the Equipment (8)5Servicing (9)5.1Cleaning (9)5.2Service Intervals (9)5.3Preventative Maintenance Kits (10)5.4Maintenance Procedures (11)5.4.1Cartridge Replacement Procedure (PCO2-400 Models Only) (11)5.4.2OIL-X Element Change Procedure (13)5.4.3Cartridge Replacement Procedure (PCO2-800 to PCO2-4800 Models) (14)5.4.4IP50 Element Change Procedure (16)6Troubleshooting (17)1 Safety InformationDo not operate this equipment until the safety information and instructions in this user guide have been read and understood by all personnel concerned.USER RESPONSIBILITYFAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation, its subsidiaries and authorised distributors provide product or system options for further investigation by users having technical expertise.The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyse all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalogue and in any other materials provided from Parker or its subsidiaries or authorised distributors.To the extent that Parker or its subsidiaries or authorised distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.Only competent personnel trained, qualified, and approved by Parker Hannifin should perform installation, commissioning, service and repair procedures.With the exception of oxygen, any gas can cause asphyxiation in high enough concentrations. Always ensure that the unit is operated in a well ventilated area and all of the vent ports on the rear of the unit are kept clear and free from blockages.Use of the equipment in a manner not specified within this user guide may result in an unplanned release of pressure, which may cause serious personal injury or damage.When handling, installing or operating this equipment, personnel must employ safe engineering practices and observe all related regulations, health & safety procedures, and legal requirements for safety.Ensure that the equipment is depressurised prior to carrying out any of the scheduled maintenance instructions specified within this user guide. Parker Hannifin can not anticipate every possible circumstance which may represent a potential hazard. The warnings in this manual cover the most known potential hazards, but by definition can not be all-inclusive. If the user employs an operating procedure, item of equipment or a method of working which is not specifically recommended by Parker Hannifin the user must ensure that the equipment will not be damaged or become hazardous to persons or property.Most accidents that occur during the operation and maintenance of machinery are the result of failure to observe basic safety rules and procedures. Accidents can be avoided by recognising that any machinery is potentially hazardous.Should you require an extended warranty, tailored service contracts or training on this equipment, or any other equipment within the Parker Hannifin range, please contact your local Parker Hannifin office.Details of your nearest Parker Hannifin sales office can be found at /gsfeRetain this user guide for future reference.Related Documents:• Preventative Maintenance Guide 176070002• 12 Month Service Instructions 1760700031.1 Markings and SymbolsThe following markings and international symbols are used on the equipment or within this manual:2 DescriptionThe Parker domnick hunter PCO2 systems offer a comprehensive solution to preserve and guarantee the quality of gaseous carbon dioxide used in sparkling beverage bottling.Operating as a Quality Incident Protection system against potential carbon dioxide impurities, the system guarantees the gas quality so itremains within industry and company guidelines, preventing detrimental consequences to the finished end beverage, producers reputation and their bottom-line.PCO2 is the beverage industry preferred choice and is installed in over 150 countries worldwide.2.1 Stages of Purification* Optional - Sterilising Grade: consult Parker for operational use.2.2 Technical SpecificationThis specification is valid when the equipment is located, installed, operated, and maintained as specified within this user guide.Stated flow rates are at 24.1 bar g (350 psi g).*Systems are installed in duplex / parallel to double the flow rate.All systems are supplied as NPT with stainless steel adapters 'NPT to BSP' as standard.PCO2 CO 2 systems are for gaseous CO 2 only.For flows at other pressures, apply the correction factors shown below.2.2.1 Pressure Correction FactorsStage 10.01 micron particle filtrationRemoval of non-volatile organic residue (NVOR) and other contaminants down to 0.01 ppmStage 2Removal of water vapour and partial removal of hydrocarbonsStage 3Primary removal of aromatic hydrocarbons (Benzene, Toulene etc and Acetaldehyde)Stage 4Removal of sulphur compounds (COS, H2S, DMS etc)Stage 50.01 micron particle filtrationStage 6*Point of use VBACE sterile gas membrane. Hi Flow Tetpor II ParameterUnitsPCO2400PCO2800PCO21600PCO22400PCO23200PCO24000PCO24800PCO23200(Duplex)*PCO24000(Duplex)*PCO24800(Duplex)*Technical DataMinimum Operating Pressure bar g (psi g) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5) 3.0(43.5)Maximum Operating Pressure bar g (psi g)20.7(300)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)24.1(350)Minimum Operating Temperature ºC (ºF)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)-20(-4)Maximum Operating Temperature ºC (ºF)40(104)40(104)40(104)40(104)40(104)40(104)40(104)40(104)40(104)40(104)Inlet CO 2 Quality ISBT beverage grade CO 2FlowrateKg / hr 1813637261089145118142177290336284354Lb / hr40080016002400320040004800640080009600Port Connections CO 2 Inlet in 1” NPT 1-1/2" NPT CO 2 Outletin1” NPT1-1/2" NPTInlet Pressurebar g 345678*********psi g44587387102116130145160174189Correction Factor 0.190.230.280.330.380.420.470.520.570.610.66Inlet Pressurebar g 1415161718192021222324psi g203218232247261275290304319333350Correction Factor0.710.760.800.850.900.95111112.3 Weights and Dimensions*Clearance required for the removal and servicing of the cartridges.Model Height (H)Width (W)Depth (D)(a)(b)(c)Clearance*Weight mm ins mm ins mm ins mm ins mm ins mm ins mm ins kg Ibs PCO2-400103540.7556422.2035013.78189.57.534013.430011.8168026.875165PCO2-800106141.7763224.8845017.72215.58.534013.440015.7568026.884185PCO2-1600106141.7780131.5445017.72215.58.550920.0440015.7568026.8128282PCO2-2400106141.7797038.1945017.72215.58.567826.7040015.7568026.8172379PCO2-3200106141.77113944.8445017.72215.58.584733.3540015.7568026.8217478PCO2-4000106141.77130851.5045017.72215.58.5101640.040015.7568026.8260573PCO2-4800106141.77147758.1545017.72215.58.5118546.740015.7568026.8304670(b)(b)PCO2-400PCO2-800 to PCO2-48002.4 Receiving and Inspecting the EquipmentOn receipt of the equipment carefully inspect the packaging for damage. If the packaging is damaged inform the delivery company immediately and contact your local Parker Hannifin office.2.4.1 StorageIf the equipment is to be stored prior to installation, do not remove it from the packaging. Ensure that it is stored in an upright position as indicated by the arrows on the packaging.Do not attempt to lift the equipment by yourself. It is recommended that the equipment be carried by a minimum of two persons ortransported on a pallet truck.Note. The storage area should be secure and the environmental conditions should fall within those specified in the technical specification.If the equipment is stored in an area where the environmental conditions fall outside of those specified, it is essential that it be moved to its final location (installation site) and left to stabilise prior to unpacking. Failure to do this could cause condensing humidity and potential failure of the equipment.2.4.2 UnpackingRemove the lid and all four sides of the packing crate. Carefully move the unit to its final location using a forklift truck or pallet truck. Once in it’s final location, remove the unit from the pallet via the 4x bolts.Note: Suitable slings and an overhead crane maybe required depending on the product size.2.4.3 Overview of the EquipmentKey:Item Description1System Inlet2System Outlet3AA020P OIL-X Filter (PCO2-400 Models only) IP50-AA-0465GPCO2 Filter4Manual Filter Drain5Manifold Lifting Handle6Manifold Hinge (PCO2-800 to PCO2-4800 Models) 7Desiccant Cartridge8PCO2 Column9Pressure Gauge10Lifting Eye Bolt7 8PCO2-400PCO2-800 to PCO2-4800 73 Installation & Commissioning3.1 Recommended system layoutOnly competent personnel trained, qualified, and approved by Parker Hannifin should perform commissioning and service procedures.1Liquid CO2 storage tank 2Vaporiser3Stainless steel piping4Pre filtration - Stage One 5PCO2 Unit6Post filtration - Stage five 7Isolation valves8Sterile Filter (Optional)54678 2313.2 Locating the Equipment3.2.1 Space RequirementsThe equipment should be mounted on a flat surface capable of supporting its own weight plus the weight of all ancillary parts. The minimum footprint requirements are specified below, however there must be adequate space around the equipment to allow airflow and access for maintenance purposes and lifting equipment. A minimum spacing of approximately 500mm (20 ins) is recommended around all sides of the unit and 750mm (30 ins) above it.Do Not position the equipment so that it is difficult to operate.3.3 Mechanical Installation3.3.1 General RequirementsEnsure that all piping materials are suitably rated for the application, clean and debris free. The diameter of the pipes must be sufficient to allow unrestricted inlet air supply to the equipment.Apply approximately 8 - 12 turns of P .T.F.E tape to the high quality stainless steel piping.Fit the piping along with the relevant pre and post filtration onto the inlet and outlet. Isolation valves must be installed before the inlet filtration and after the outlet filtration.When routing pipes ensure that they are adequately supported to prevent damage or leaks in the system.All components used within the system must be rated to at least the maximum operating pressure of the equipment. It is recommended that the system is protected with suitably rated pressure relief valves.3.3.2 Securing the UnitMounting holes are provided in the feet of the unit. Once the unit has been positioned in its final location ensure that it is securely fixed in place.500mm (20ins)(20ins)500mm(20ins)4 Operating the Equipment4.1 Starting the EquipmentNote: On start-Up it is normal for the outlet temperature to increase for a limited period of time.1 Open the inlet valve slowly to gradually pressurise the PCO2 unit.2 Open the outlet valve slowly to re-pressurise the downstream piping.Do not open the inlet or outlet valves rapidly or subject the PCO2 unit to excessive pressure differential as damage may occur.5 Servicing5.1 CleaningClean the equipment with a damp cloth only. If required you may use a mild detergent, however do not use abrasives or solvents as they may damage the warning labels on the equipment.5.2 Service IntervalsParker recommend that the adsorbent cartridges and filter elements are exchanged within the recommended 12-month period or before the recorded cumulative mass of the unit has been exceeded or after a quality incident has occurred, whichever comes first. Please refer to the below table for the maximum mass flow of each model.Service12 M o n t h s24 M o n t h s36 M o n t h s48 M o n t h s60 M o n t h s72 M o n t h sAPCO2 Model Number Max Operating Pressure Bar/PSI Flow kg/hr @ Max OperatingPressureMax Mass over 12 Months:kgFlow lb/hr@ Max OperatingPressureMax Mass over 12 Months:IbMax Mass over 12 Months: Tonne (Metric Ton)PCO2-40020 Barg / 300 PSIG 181158121640034944001581PCO2-80024 Barg / 350 PSIG 363317116880069888003170PCO2-160024 Barg / 350 PSIG 72663423361600139776006340PCO2-240024 Barg / 350 PSIG 108995135042400209664009510PCO2-320024 Barg / 350 PSIG 14511267593632002795520012680PCO2-400024 Barg / 350 PSIG 18141584710440003494400015850PCO2-480024 Barg / 350 PSIG 21771901827248004193280019020PCO2-3200 (Duplex)24 Barg / 350 PSIG 29032536060864005591040025361PCO2-4000 (Duplex)24 Barg / 350 PSIG 36283169420880006988800031701PCO2-4800 (Duplex)24 Barg / 350 PSIG435438036544960083865600380415.3 Preventative Maintenance KitsRequired every 8000Hrs (12 months)PCO2-400PCO2-800 to PCO2-4800AAAModelPM Kit NumberKit ContentsOrder QuantityPCO2 400MK-PCO2-4001x Desiccant cartridges 2x Outlet block o-rings 2x P020AA Filter element 2x Filter bowl o-rings 1PCO2 800MK-PCO2-8002x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 1600MK-PCO2-16004x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 2400MK-PCO2-24006x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 3200MK-PCO2-32008x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 4000MK-PCO2-400010x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 4800MK-PCO2-480012x Desiccant cartridges 2x Outlet block o-rings 2x IP50-AA Filter element 2x Filter bowl o-rings 1PCO2 3200 (Duplex)MK-PCO2-640016x Desiccant cartridges 4x Outlet block o-rings 4x IP50-AA Filter element 4x Filter bowl o-rings 1PCO2 4000 (Duplex)MK-PCO2-800020x Desiccant cartridges 4x Outlet block o-rings 4x IP50-AA Filter element 4x Filter bowl o-rings 1PCO2 4800 (Duplex)MK-PCO2-960024x Desiccant cartridges 4x Outlet block o-rings 4x IP50-AA Filter element 4x Filter bowl o-rings1With OIL-X IP50 filter elements (PCO2-800 to PCO2-4800)With OIL-X filter elements (PCO2-400 Models only)5.4 Maintenance Procedures5.4.1 Cartridge Replacement Procedure (PCO2-400 Models Only)Ensure that the system is fully depressurised before carrying out the below maintenance procedures.A Remove the M12 nuts from one side of the manifold.B Using the handle, carefully lift and remove the manifold from the unit and store in a safe place.Ensure that the inlet and outlet piping is adequately supported before removing the manifold from the unit.C Remove the old desiccant cartridges and dispose in accordance with local regulations.D Remove the o-ring from the outlet manifold block and replace with the one provided within the 12 month Preventative Maintenance kits.Note: Apply a light coating of Molykote III grease to the o-rings.E Insert the replacement desiccant cartridges into the columns.F Refit the manifold and secure the M12 nuts in sequence, starting with the centre nuts and working outwards. The nuts should be secured intwo stages. Stage 1: 27Nm (20 ft.lb) and Stage 2: 40Nm (30 ft.lb).A5.4.2 OIL-X Element Change ProcedureA Ensure that the filters are fully depressurised by opening the manual drain.B Unscrew the filter bowl and remove the used element.C Replace the o-ring located on the filter bowl with the new one provided within the 12month Preventative Maintenance kits.D Insert the new element into the filter bowl ensuring that the lugs are correctly seated inthe grooves.E Refit the filter bowl to the head ensuring that the threads are fully engaged and thelocking details are aligned.F Close the manual drain and re-pressurise the system.We recommend the use of gloves when touching contaminated elements.Ensure to lubricate the o-ring and threads with Molykote III grease.Item Description Item Description1Filter head4Filter bowl o-ring2Filter bowl5Manual Drain3Element5.4.3 Cartridge Replacement Procedure (PCO2-800 to PCO2-4800 Models)The top manifold has been split into two sections in order to simplify the removal of the desiccant cartridges.Ensure that the system is fully depressurised before carrying out the below maintenance procedures.A Remove the M12 nuts from one side of the manifold.B Using the handles, carefully lift the manifold until the M8 hex bolt has travelled to the top of the manifold hinge. Gently pull the manifoldtowards yourself until it has locked into position.C Carefully rotate the manifold 180o as shown. Once opened, place an M10 locking bolt through the holes in the two halves of the hinges toprevent the manifold falling onto the operator during service.Take care not to trap fingers/hands on the handles when rotating the manifold.D Remove the old desiccant cartridges and dispose in accordance with local regulations.Note: The cartridges should only be lifted using the handles and directly upwards to prevent clashing with the hinged manifold.E Remove the o-ring from the outlet manifold block and replace with the one provided within the 12 month Preventative Maintenance kits.Note: Apply a light coating of Molykote III grease to the o-rings.F Insert the replacement desiccant cartridges into the columns.Refit the manifold and secure the M12 nuts in sequence, starting with the centre nuts and working outwards. The nuts should be secured in two stages. Stage 1: 27Nm (20 ft.lb) and Stage 2: 40Nm (30 ft.lb).Replace the desiccant cartridges on the opposite side following the same procedure as above.5.4.4 IP50 Element Change ProcedureA Ensure that the filters are fully depressurised by opening the 1/4” BSPT ball valves.B Unscrew the filter bowl and then the used element from the tie rod.C Replace the o-ring located on the filter bowl with the new one provided within the 12month Preventative Maintenance kits.D Fit the new element onto the tie rod and tighten.E Refit the filter bowl to the head ensuring that the threads are fully engaged.F Close the 1/4” BSPT ball valves and re-pressurise the system.We recommend the use of gloves when touching contaminated elements.Ensure to lubricate the o-ring and threads with Molykote III grease.Item Description Item Description1Filter head4Element2Filter bowl5Filter bowl o-ring3Tie rod61/4” BSPT ball valve6 TroubleshootingProblem Indication Possible Cause Action RequiredPoor dewpoint Condensed water downstream ofthe system Bulk water carried over into thePCO2 unitCheck pre-filtration elements anddrainsOverflow of the PCO2 unitCompare flow through the PCO2unit to rated flowCheck for modifications to thecompressed air systemInlet pressure too low Check functioning of thecompressorInlet temperature too highCheck functioning of thecompressorCheck ventilation around the dryer Contaminated desiccantLocate and eliminate source ofcontamination and replace thedesiccantHigh pressure drop through filter / system package Pressure gauges fitted tocompressor / trainBlocked filters Replace any blocked filtersOverflow of the PCO2 unit Eliminate conditions leading toover flowOutlet air flow stops Indicated downstream pressuredrops to zero Compressor failure Investigate problem with the compressor and correctEU /-EC Type-examination Certificate:COV0912556/1Notified body for PED:Notified Body for ATEX:----B + DPED Assessment Route:29 April 2019Steven RohanDate:Signature:Parker Hannifin Manufacturing Limited GSFEDeclaration Number:00308Authorised Representative29.4.19--Lloyd's Register Verification 71 Fenchurch Street,London, EC3M 4BS-Standards used----Parker Hannifin Manufacturing Limited GSFEDukesway,Team Valley Trading Estate,Gateshead, Tyne & Wear,NE11 0PZ, UK PCO2 Carbon Dioxide Quality Incident Protection SystemGenerally in accordance with ASME VIII Div 1:2017and AS1210:2010PED----ENDeclaration of Conformity-Division Engineering Manager,This declaration of conformity issued under the sole responsibility of the manufacturer.DeclarationDirectives2014/68/EU -------PEDPCO2-400, PCO2-800, PCO2-1600, PCO2-2400, PCO2-3200, PCO2-4000, PCO2-4800Parker Hannifin Manufacturing Limited Gas Separation and Filtration Division EMEA Dukesway, Team Valley Trading Est Gateshead, Tyne and Wear England NE11 0PZTel: +44 (0) 191 402 9000Fax: +44 (0) 191 482 /gsfe© Parker Hannifin Corporation. All rights reserved.Catalogue: 176********/20 Rev: AEurope, Mi dd le East, AfricaAE – Unite d Arab Emirates, DubaiTel: +971 4 8127100********************AT – Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0*************************AT – Eastern Europe, Wiener NeustadtTel: +43 (0)2622 23501 900****************************AZ – Azerbaijan, Baku Tel: +994 50 2233 458****************************BE/LU – Bel g ium, Nivelles Tel: +32 (0)67 280 900*************************BY – Belarus, Minsk Tel: +375 17 209 9399*************************CH – Switzerlan d , Etoy Tel: +41 (0)21 821 87 00*****************************CZ – Czech Republic, Klecany Tel: +420 284 083 111*******************************DE – Germany, Kaarst Tel: +49 (0)2131 4016 0*************************DK – Denmark, Ballerup Tel: +45 43 56 04 00*************************ES – Spain, Madrid Tel: +34 902 330 001***********************FI – Finlan d , Vantaa Tel: +358 (0)20 753 2500parker.fi ****************FR – France, Contamine s/Arve Tel: +33 (0)4 50 25 80 25************************GR – Greece, Athens Tel: +30 210 933 6450************************HU – Hun g ary, Budapest Tel: +36 1 220 4155*************************IE – Irelan d , Dublin Tel: +353 (0)1 466 6370*************************IT – Italy, Corsico (MI)Tel: +39 02 45 19 21***********************KZ – Kazakhstan, Almaty Tel: +7 7272 505 800****************************NL – The Netherlan d s, Oldenzaal Tel: +31 (0)541 585 000********************NO – Norway, Asker Tel: +47 66 75 34 00************************PL – Polan d , Warsaw Tel: +48 (0)22 573 24 00************************PT – Portu g al, Leca da Palmeira Tel: +351 22 999 7360**************************RO – Romania, Bucharest Tel: +40 21 252 1382*************************RU – Russia, Moscow Tel: +7 495 645-2156************************SE – Swe d en, Spånga Tel: +46 (0)8 59 79 50 00************************SK – Slovakia, Banská Bystrica Tel: +421 484 162 252**************************SL – Slovenia, Novo Mesto Tel: +386 7 337 6650**************************TR – Turkey, Istanbul Tel: +90 216 4997081************************UA – Ukraine, Kiev Tel +380 44 494 2731*************************UK – Unite d Kin gd om, Warwick Tel: +44 (0)1926 317 878********************ZA – South Africa, Kempton Park Tel: +27 (0)11 961 0700*****************************North AmericaCA – Cana d a, Milton, Ontario Tel: +1 905 693 3000US – USA, Cleveland Tel: +1 216 896 3000Asia Pacifi cAU – Australia, Castle Hill Tel: +61 (0)2-9634 7777CN – China, Shanghai Tel: +86 21 2899 5000HK – Hon g Kon g Tel: +852 2428 8008IN – In d ia, MumbaiTel: +91 22 6513 7081-85JP – Japan, Tokyo Tel: +81 (0)3 6408 3901KR – South Korea, Seoul Tel: +82 2 559 0400MY – Malaysia, Shah Alam Tel: +60 3 7849 0800NZ – New Zealan d , Mt Wellington Tel: +64 9 574 1744SG – Sin g apore Tel: +65 6887 6300TH – Thailan d , Bangkok Tel: +662 186 7000-99TW – Taiwan, Taipei Tel: +886 2 2298 8987South AmericaAR – Ar g entina, Buenos Aires Tel: +54 3327 44 4129BR – Brazil, Sao Jose dos Campos Tel: +55 800 727 5374 CL – Chile, Santiago Tel: +56 2 623 1216MX – Mexico, Apodaca Tel: +52 81 8156 6000Parker WorldwideEuropean Pro d uct Information Centre Free phone: 00 800 27 27 5374(from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA)。
航空航天仪器仪表机电过滤流体与气体处理液压气动过程控制密封与屏蔽2Parker Hannifin Corporation Pneumatic Division - EuropePHCPNE0005P1A 气缸特点气缸 液压缸 电动缸负载安全 *** *** *负载大小 *** *** *速度变化 *** *** *速度 *** ** **可靠性 *** *** ***坚固 *** *** *安装成本 *** * **维修成本*** ** *潮湿环境下的安全性 *** *** *爆炸环境下的安全性 *** *** *电气装置的安全风险 *** *** *抗漏油的风险 *** * ***清洁卫生 *** ** *尺寸标准化 *** *** *使用寿命*** *** *需要液压系统配合 *** * ***重量 ** ** **采购价格 *** ** *功率密度 ** *** *产生噪音 ** *** **推力尺寸比 ** *** *定位 * *** ***能量消耗 * ** ***保养周期 * ** ***需要压缩机 * *** **** = 好,**=中等,***=优秀3Parker Hannifin Corporation Pneumatic Division - EuropePHCPNE0005P1A 气缸内容 页码ISO 气缸系列,P1A ........................................................................................4-5气缸作用力 .........................................................................................................6主要参数.............................................................................................................7工作介质,空气质量 ..........................................................................................7材料参数.............................................................................................................8缓冲性能.............................................................................................................8尺寸 ....................................................................................................................9选择合适的管路..........................................................................................10-11订购代码...........................................................................................................12标准行程...........................................................................................................12P1A 单作用气缸订购指南..................................................................................13P1A 双作用气缸订购指南............................................................................14-15P1A 气缸导杆 ..............................................................................................16-18气缸附件.....................................................................................................19-22传感器 ........................................................................................................23-26带一个插头的电缆 ............................................................................................27电缆连接的公接头 .. (27)4Parker Hannifin Corporation Pneumatic Division - EuropePHCPNE0005P1A 气缸双作用和单作用气缸P1A 系列气缸的设计使其适用广泛的应用场合。
派克PV系列轴向柱塞泵【产品详情】美国Parker派克PV系列轴向柱塞泵--使用注意事项1、油泵使用安装位置,泄油口朝上,管路背压须低于0.2MPa单独回油箱。
2、最高压力使用,每一循环运转时间不超过6秒、液压油清洁规范,请参见使用说明书。
3、本公司提供多连油泵,亦可与其他形式油泵连结,连结方式采用标准的公制连接尺寸和SAE连接尺寸。
4、其他事项请参照本公司综合样本。
美国Parker派克PV系列轴向柱塞泵--型号说明派克PVP系列轴向柱塞泵【产品详情】Parker派克PVP系列轴向柱塞泵最大排量从16至140ml/rev,额定工作压力为250bar,最低转速为每分钟500转。
型号有:PVP016, PVP023, PVP033, PVP041, PVP048,PVP060, PVP076, PVP100, PVP140等。
派克PV/PV系列双联轴向柱塞泵【产品详情】隆兴公司专业销售派克柱塞泵。
PV系列轴向柱塞泵有带标准压力调节器和带功率调节器两种选择。
最大排量从16至270ml/rev,额定工作压力为350bar,最低转速为每分钟300转,泄油口朝上。
派克柱塞泵PV系列:PV016, PV020, PV023, PV032, PV040, PV046, PV063, PV080, PV092, PV140, PV180, PV270等。
派克柱塞泵PAVC系列:PAVC33,PAVC38,PAVC65,PAVC100Parker派克PV/PV系列双联轴向柱塞泵是由两个PV系列轴向柱塞泵组合而成,可以提供不同的排量组合。
单个泵的最大排量从16至270ml/rev,额定工作压力为350bar,最低转速为每分钟300转,泄油口朝上。
派克PAV6.3和PAV10系列轴向柱塞泵【产品详情】Parker派克PAV6.3和PAV10系列轴向柱塞泵为斜盘式变量柱塞泵,用于开式回路。
单泵形式,调节器法兰式连接于PAV6.3之上、螺纹拧入式连接于PAV10之上。
Electronic SensorsContents - /pneu/actuators Catalog 0900P-7Parker PneumaticElectronic and Reed Sensors Product Overview L2Technical Data L3DimensionsL4Connection Type and Diagram L5Ordering Information L6Continuous Position Sensors Product Overview L7Techncal Data L8DimensionsL9Connection Type and Diagram L9Ordering Information L9AccessoriesMounting and Brackets L10Connectors and CablesL11Pneumatic Sensor for Tie Rod Cylinders Product Overview L12Techncal Data L12DimensionsL12Product OverviewThe P8S Series magnetic cylinder sensor enables quick, precise and contactless sensing of the piston’s position in cylinders. It is easy to mount, can be used in numerous applications and offers an outstanding price-performance ratio.Product OverviewAs the term magnetic switch suggests, these are operated by magnetic fields; another description widely used is magnetic “SENSOR”. As our eyes sense change of light, our ears sense the change of sound, magnetic sensors / switches sense the change of magnetic flux in pneumatic and hydraulic cylinders. When magnetic sensors sense a magnetic field it will give a switching signal, through a control circuit, allowing sensing or control operation to be achieved.Because of the characteristics of magnetic sensors they can sense a change of magnetic field relative to the position of the magnet, such as in a pneumatic or hydraulic cylinder, whereby the magnet is attached to a moving piston and thus the position of the moving part (ie Piston) can be detected. The magnet is mounted on the piston of the cylinder and thus moves with the piston.The magnetic sensor (switch) is fixed either directly to the cylinder or with an additional mounting bracket. When the piston (magnet) moves to the position under a magnetic sensor, the switch will operate due to the change of the magnetic field and give a switching signal.Thus the position of the piston can be identified and a resulting signal generated to continue the sequence of a circuit.Magnetic sensors available can be classified into two different groups, they are sensors with contacts which are called mechanically operated or reed sensors and the other type is sensors without contacts and are called solid state type or electronic.Parker P8S Series sensors are suitable for use with a large range of actuators. They can either be inserted directly into the cylinder tube extrusion or mounted using additional brackets. For direct mounting the sensor is positioned within the cylinder sensor groove, offering mechanical protection, then securely clamped into position by a simple turn of a screw. For other cylinder versions there are a number of optional sensors brackets that clamp to the cylinder and offer other mounting positions.For easy installation there are several cable lengths available with either M8 connector or flying lead. The electronic sensors are “Solid State”, i.e. they have no moving parts. They are provided with short-circuit protection and transient protection as standard. The built-in electronics make the sensors suitable for applications with high on and off switching frequency where long service life is required.Please note that for low temperature applications sensors are normally specified for full performance down to -30°C only. High temperature cylinders do not have a magnetic piston and therefore cannot be used with sensors.P8S Electronic and Reed SensorsDimensions, mm (inch)PNP, NPN Output 10 to 30 V DC Reed Output 5 to 230 V AC/DCScrew 1/4 turnConnection Type and DiagramPNP NONPN NO NPN NCReed NO 3-wirePin assignment, M8 with knurled nut bn: brown bk: black bu: blue Q: load M: Mass L+: PowerPNP NCReed NO 2-wireReed NC 2-wire+ -Q NAMUR NO ATEX 1G, 1DPNP NO ATEX 3G, 3DFlying leads4 (out)3 (-)1 (+)bnbubkConnectionsSquare body design, insert straight in T-slot, screw 1/4 turnNote:-30 to +80 °C (PUR cable) I -30 to + 70 °C (PVC cable) I -25 to +80 °C (NAMUR 1GD I -20 to +50 °C (ATEX 3GD) All sensors come with an adapter for S-dovetail Parker type OSP grooves. * with an aluminium adapterOrdering InformationMany applications require more than just end of stroke sensing of an actuator, but traditional methods of continuous sensing are expensive to implement. Parker’s CPS (Continuous Position Sensor) enables quick, precise and contactless continuous position sensing of a magnetic piston.CPS sensors continuously supply data via analog outputs or IO-Link. Analog position sensors have a voltage output of 0 V ... 10 V as well as a current output of 4 mA ... 20 mA. CPS enables flexible machine concepts, making it possible to solve tasks in areas such as quality monitoring and process control in conjunction with pneumatic cylinders. This continuous transfer of position data upgrades the functionality of the pneumatic cylinders by making them more intelligent, and as a result, more versatile. CPS settings can be adjusted during or after installation using a teach button or using IO-Link.CPS can be mounted directly in standard T -slots without the need for additional accessories. Mounting on other cylinder types, (round, tie rod) is possible with adapters.• Continuous position sensing• IO-Link communication with M12 connector • No modification to the actuator • Analog version with M8 connector• 5 sizes with sensing ranges from 32 mm to 256 mm • IP67 design suitable for any industrial application • Yellow teach button for easy set-upTechnical specification:1 ms sampling rate0.03% full scale resolution 0.06% full scale repeatability 0.3 mm Linearity errorHow it works:The CPS product detects the position of an actuator via the magnet on the piston. The sensor settings can easily be adjusted during installation using the yellow teach button or during operation over the IO-Link communication. This upgrades the functionality of the pneumatic actuator by making it more intelligent and versatile in support of the Industry 4.0 initiative.How it connects:Analog version has a M8 connector and a voltage output of 0-10V as well as a current output of 4-20mA. IO-Link version has a M12 connector and transmits position via 2 bytes of process input data and also allows for parameter control of measuring range and locking of the teach button.It can be controlled by Class A or Class B IO-Link Masters.Without Adapter:Direct drop-in T -slotT-slot dimensions [mm ± 0.1]1) Pivot sensor into the slot2) Teach the CPS unit the desired measuring range 3) Tighten set screws5.554.806.803.40How it installs:The Parker CPS requires the use of a magnetic piston. The product will ft T -slot cylinders without any additional mounting hardware.Product OverviewP8S Continuous Position Sensors1) ± 1 mm 2)Reverse-polarity protected, operation in short-circuit protected network: max. 8 A. 3) Without load 4)Power output, at 24 V 5)Voltage output6) FSR: Full Scale Range;max. measuring range. 7)At 25°C, linearity error (maximum deviation)depending on response curve and minimal deviation function. 8)At 25°C, repeatability magnet movement in one direction. 9)Only in standard mode, not in IO-Link mode. 10)The analogue measured value can deviateunder transient conditions.Installation: Drop in, fixed by allen key 1.5 mm Measuring range:32 to 256 mm depending on type 1)Housing length:45 to 269 mm depending on type Output Function: Analog | IO-Link Analog output (voltage):0 to 10 V | -Analog output (current): 4 to 20 mA | -Teach-in:YesEnclosure rating:IP 67 (according to EN 60529)Supply Voltage: 2)15 to 30 V DCPower consumption: 3)<= 22 mA (analog) | <= 25 ma (IO-Link)Max load resistance: 4)<= 500 ΩMin load resistance: 5)<= 2 kΩProtection class:III Time delay before availability: 1.5 sRequired magnetic field sensitivity: 3 mT / 2 mT (analog) | 3 mT (IO-Link)Resolution: 6)0.03% full scale range (max >=0.05 mm)Linearity error: 7) 0.3 mmRepeat accuracy: 8)0.06% full scale range (>= 0.1 mm)Sampling rate: 9)1 msIndication LED color: Yellow (analog)Reserve polarity protection:Yes (analog)Short circuit protection:Yes (analog)Ambient operating temperature range:-20 to +70 °C (PUR cable)Shock and vibration resistance:30 g 11 ms / 10 … 55 Hz, 1 mm EMC: 10)According to EN 60947-5-2International standard:CE | C UL US | CCC (not applicable) | RoHs | IO-Link UL file No:On requestHousing material:Plastic polyamid PA12Screw material: Stainless steel Cable material:PUR (Polyurethane)Conductor cross-section:0.08 mm²Connector:M12 (IO-Link) or M8 (analog)TechnicalDimensions, mm (inch)Connection Type and DiagramPart NumberL1L2 *L3Analog IO-Link 453240P8SAGACHA P8SAGHMHA 776472P8SAGACHB P8SAGHMHB 141128136P8SAGACHD P8SAGHMHD 205192200P8SAGACHF P8SAGHMHF269256264P8SAGACHHP8SAGHMHH*L2 equal to the measuring range.OutputMeasuring Length ConfigurationOptionPart Number Weight [g]For Product SeriesAnalog32 mm Teach ButtonP8SAGACHA 16With T -slot groove *64 mmP8SAGACHB 26128 mm P8SAGACHD 46192 mm P8SAGACHF 66256 mm P8SAGACHH 86IO-Link32 mm Teach Button or IO-Link parameter P8SAGHMHA 20With T -slot groove *64 mmP8SAGHMHB 30128 mm P8SAGHMHD 50192 mm P8SAGHMHF 70256 mmP8SAGHMHH90* Required magnetic field sensitivity: 3mT / -2 mT (Analog) / 3mT (IO-Link) Note:PUR cable with M12 (IO-Link) or M8 (Analog) male connector knurled nut, 4-pin, 0,3 meter length. Please consult for measuring range 96, 160 & 224 mm.Ordering Information, Drop-in T-slotNote:PUR cable with M12 (IO-Link) or M8 (Analog) male connector knurled nut, 4-pin, 0,3 meter length. Please consult for measuring range 96, 160 & 224 mm.IO Link version PUR 0.3 meter length with M12 male connector knurled nut, 4-pin PUR 0.3 meter length with M8 male connector knurled nut, 4-pinbrn wht blk bluAnalog versionbrn blk whtbluDimensions, Ordering InformationFor Products SeriesPart Number Weight [g]Tie rods, 4MA, P1F , P1D, PTR, 2MNR P8S-TMAOX 65Tie rods, P1F-T Ø 32-100P8S-TMA0710Tie rods, P1F-T Ø 125-320P8S-TMA0832T -Slot OSP Ø 108872FIL 3T -Slot 2002 Series Ø 168865FIL 4T -Slot 2002/P120 Series Ø 25-808866FIL 5Round cylinder Ø10-25P8S-TMC0127Round cylinder Ø 32-63P8S-TMC0229Round cylinder Ø 80-125P8S-TMC0332S-Dovetail OSP , pack of 10P8S-TMA0910Ambient temperature -30 to +80 °CP8S-TMC01, 02 & 03Part number D [mm]P8S-TMC018 to 25Clamping ring in nickel silver, screw in stainless steel, sensor mounting zinc diecastP8S-TMC0232 to 63P8S-TMC0380 to 130All mountings can be moved on the cylinder body before screwing in place and then putting sensors in the slots.P8S-TMAOX(Zinc diecast, zinc plated screws.)Ø min. 5 (.2);1 Sensoradapter with T-slot 2 Fixing for cable < Ø 3.2 mm (0.126 inch)3 Cylinderadapter 3 Mounting screws M5Dimensions, mm (inch)Mountings and Brackets① Sensor adapter with T -Slot ② Fixing for cable < Ø 3.2 mm (0.126 inch)③ Cylinder adapter ④ Mounting screws M5Tie Rod Bracket Assembly is necessary for Global and Mini-Global Sensor installation on all tie rod construction cylinders. This includes all Intermediate Trunnion mounts (Style DD or MT4); and all 6"-8" bore Sensors and bracket assemblies must be ordered separately.Part number P8S-TMAOX fits 1-1/2" to 8" bores and32-200mm bores for Global SensorsP8S-TMAOXTie Rod Bracket AssemblyCatalog 0900P-7AccessoriesElectronic SensorsMountings and Brackets(Revised 05-06-21)Cable connectors for producting your own connecting cables.The conncectors can be quickly attached to the cable without special tools. Only the outer sheath of the cable is removed. The connectors are available for M8 screw connector and meet protection class IP65.Male Connectors for Connecting CablesOpertaing current per contact:max. 4 AConnection cross section:0.25... 0.5 mm² (conductor diameter min 0.1 mm)Protection class:IP65 and IP67 when plugged and screwed down (EN 60529)Temperature range:- 25... + 85°CDescriptionPart Number Weight [g]For Product Series Cable flex PVC 3 meter with 8mm snap-in connector / flying leads 912634434170P8S Sensors with M8Cable flex PVC 10 meter with 8mm snap-in connector / flying leads 9126344342210P8S Sensors with M8Cable PUR 3 meter with 8mm snap-in female connector / flying leads 912634434570P8S Sensors with M8Cable flex PUR 10 meter with 8mm snap-in connector / flying leads 9126344346210P8S Sensors with M8Cable PVC 5 meter with M8 screw female connector / flying leads KC3104120P8S Sensors with knurled M8*Note: not applicable for P8S CPS Sensors as no cable availableCables to extend cable sensor lengths with M8*Connector Weight [kg] Part numberM8 screw connector P8CS0803J M12 screw connector0.022P8CS1204JCatalog 0900P-7AccessoriesElectronic SensorsMale Connectors and Cables(Revised 06-19-21)Pneumatic Sensor for Tie-Rods CylindersAn ideal solution where a direct pneumatic signal is wanted from a cylinder sensor to a pneumatic control system, for example. This could be a machine or device in which only compressed air is available, and an electricity supply to normal cylinder sensors would involve serious problems or considerable expense.Function:Non-contacting sensing of a pneumatic cylinder, triggering an output signal (conn. 2) from the integrated 3/2 NC valve, which is activated by a magnetic field or iron core and has a return spring.If more than one sensor is used with a cylinder there must be a distance of at least 20 mm between sensors to prevent them influencing each other.To avoid interference, there must be a minimum spacing of 15 mm to steel details.The outlet (conn. 3) must not be blocked or restricted as this can impair the function of the sensor.The sensor is fastened to the cylinder using the special sensor fixing.Technical data:Working pressure: min 2 to max 6 bar Temperature: -15 to +60 °CAir quality: 3.4.3 to ISO 8573-1 (must be oil free)Function: 3/2 NC valve Flow:40 Nl per minuteConnection: for plastic pipe with 2,5-3 mm internal diameterActivation distance: for magnet: min 9 mm Activation distance: for Fe: approx. 2 mm Repetition accuracy: +/- 0.2 mmCylinder velocity:max 1 m/s (depends on magnetic field, interference from steel in environment, signal length requirement from control system….)Distance between sensors: min 20 mmDistance from sensor to steel details: min 15 mmFixing: with sensor fixing or with an M4 thread in caseSensing:non-contacting (also through awall of non-magnetic material)Cylinder fixing -Tie-Rod Cylinders Ø 32 to 100 mmDimensions (mm)iron coreCatalog 0900P-7TechnicalElectronic Sensors Pneumatic SensorsDescription Weight (kg)Part Number Pneumatic sensor0.02P8S-A34X Cylinder fixing bore Ø32to Ø125 mm0.01P8S-AMA1。
美国派克PARKER气缸,parker液压油缸知识介绍美国parker派克气缸:派克汉尼汾的Parker气缸用于液压,气动,电气和航空航天系统的气缸,包含单杆,双杆和无杆设计的气缸。
具有广泛的安装方式,材料,密封符合选项,反馈协议和结构类型,从轻型铝制空气气缸,到用于移动或工业设备的重型液压设计,再到用于航天航空应用的制动和执行器气缸。
Parker派克气缸派克P1D标准气缸全新的,革新的P1D气缸是派克汉尼汾公司推出的一种能经受得住未来考验的一代ISO/VDMA 气缸。
这种气缸是双作用的,带有新型的气缓冲。
质量轻,硬度高的缸筒有传感器沟槽,使得传感器安装简单,并可保护传感器。
派克气缸派克P1D标准气缸安装尺寸符合国际标准新的P1D气缸符合现有的ISO6431,ISO/DIS15552,VDMA24562和AFNOR安装尺寸标准。
确保世界范围的客户使用。
高技术设计为了能提供最好的产品,我们选用了最好的材料,最好的加工方法,对每个细节处的设计都进行仔细的测试和试验。
气缸内部的元是高强度塑料做成的,这样使得气缸运动平稳,无噪声,使用寿命长。
铝合金端盖和抗扭矩的铝合金缸筒使气缸耐用并适用于很多种应用场合。
高质量P1D气缸在以下的每一阶段都是经过高质量开发的-规格需求,设计,计划,采购,生产,分销和服务。
我们在10年前就通过了ISO9001 QA标准的质量认证。
产品和服务的高质量是我们的口号。
更多的功能和不同P1D气缸有所有通用功能的设计,比如:双活塞杆气缸,高/低温气缸,液压操作气缸,加长活塞杆气缸等。
新的特殊的不同点是P1D气缸具有*的自润滑型HDPE刮尘圈和活塞杆密封,这种特殊的设计适用于需要活塞杆完全干燥的场合(如活塞杆上的油脂层经常被冲洗掉的场合)。
Parker派克液压油缸的保养说明因为液压油缸要承受很大的压强,负载越重,它的压强就会越大,因此,做好液压油缸的保养工作是整个液压系统的维护zui重要的一环。
神威气动 文档标题:派克origa无杆气缸一、派克origa无杆气缸的介绍:引导活塞在缸内进行直线往复运动的圆筒形金属机件。
空气在发动机气缸中通过膨胀将热能转化为机械能;气体在压缩机气缸中接受活塞压缩而提高压力。
涡轮机、旋转活塞式发动机等的壳体通常也称“气缸”。
气缸的应用领域:印刷(张力控制)、半导体(点焊机、芯片研磨)、自动化控制、机器人等等。
二、气缸种类:①单作用气缸:仅一端有活塞杆,从活塞一侧供气聚能产生气压,气压推动活塞产生推力伸出,靠弹簧或自重返回。
②双作用气缸:从活塞两侧交替供气,在一个或两个方向输出力。
③膜片式气缸:用膜片代替活塞,只在一个方向输出力,用弹簧复位。
它的密封性能好,但行程短。
④冲击气缸:这是一种新型元件。
它把压缩气体的压力能转换为活塞高速(10~20米/秒)运动的动能,借以做功。
⑤无杆气缸:没有活塞杆的气缸的总称。
有磁性气缸,缆索气缸两大类。
做往复摆动的气缸称摆动气缸,由叶片将内腔分隔为二,向两腔交替供气,输出轴做摆动运动,摆动角小于280°。
此外,还有回转气缸、气液阻尼缸和步进气缸等。
三、气缸结构:气缸是由缸筒、端盖、活塞、活塞杆和密封件等组成,其内部结构如图所示:2:端盖端盖上设有进排气通口,有的还在端盖内设有缓冲机构。
杆侧端盖上设有密封圈和防尘圈,以防止从活塞杆处向外漏气和防止外部灰尘混入缸内。
杆侧端盖上设有导向套,以提高气缸的导向精度,承受活塞杆上少量的横向负载,减小活塞杆伸出时的下弯量,延长气缸使用寿命。
导向套通常使用烧结含油合金、前倾铜铸件。
端盖过去常用可锻铸铁,为减轻重量并防锈,常使用铝合金压铸,微型缸有使用黄铜材料的。
3:活塞活塞是气缸中的受压力零件。
为防止活塞左右两腔相互窜气,设有活塞密封圈。
活塞上的耐磨环可提高气缸的导向性,减少活塞密封圈的磨耗,减少摩擦阻力。
耐磨环长使用聚氨酯、聚四氟乙烯、夹布合成树脂等材料。
活塞的宽度由密封圈尺寸和必要的滑动部分长度来决定。
液压注意 – 用户方责任 错误或不当地选择或使用本样本或有关资料阐述的产品,可能会导致人生伤亡及财产损失! 本样本以及其它由派克汉尼汾公司及其子公司、销售公司与授权分销商所提供的资料,仅供用户专业技术人员在对产品和系统的选型进行深入调查考证时参考。
用户应全面分析自身设备的运行工况、适用的工业标准,并仔细查阅现行的样本,以详细地了解产品及系统的相关信息,通过自己的分析和试验,对产品及系统的独立的最终选择负责,确保能满足自身设备的所有性能、耐用性、维修型、安全性以及预警功能等要求。
对于派克或其子公司或授权分销商而言,应负责按用户提供的技术资料和规范,选择和提供适当的元件或系统,而用户则应负责确定这些技术资料和规范对其设备的所有运行工况和能合理预见的使用工况是否充分和准确。
目录目录页次概述 1 订货代号 2 技术参数 4 变量控制器 5 控制选项 “C”, 压力限定(恒压)变量控制器 5 控制选项 “L”, 负载传感及压力限定变量控制器 6 控制选项 “AM”, 带遥控口的标准型先导式压力限定变量控制器 7 控制选项 “AN”, 带ISO 4401 NG06先导阀安装界面的先导式压力限定变量控制器 8 控制选项 “AE”及“AF”, 带电磁比例调节的先导式压力限定变量控制器 9 控制选项 “AMT”, “ALT”及“LOT”, 带最高压力限定的扭矩限定(恒功率)变量控制器 10 P1性能特性 11典型流量特性 11 典型总效率特性 13 典型轴输入功率特性 15 典型噪声特性 18 典型轴承寿命 20 PD性能特性 22典型流量特性 22 典型总效率特性 24 典型轴输入功率特性 26 典型噪声特性 29 典型轴承寿命 31 安装尺寸 33 P1/PD 018 33 P1/PD 028 36 P1/PD 045 40 P1/PD 060 44 P1/PD 075 49 P1/PD 100 54 P1/PD 140 59 变量控制器安装尺寸 65 可提供的扩展的液压产品 75派克汉尼汾备记派克汉尼汾概述简介, 优点派克汉尼汾简介 • 开式回路用轴向柱塞式变量液压泵 • 中压,连续工作压力280 bar • 高驱动转速型,适用于行走机械; 低噪声型,适用于工业应用 • 静音及高效的控制效能 优点 • 总结构尺寸紧凑 • 低噪声• 流量脉动小,进一步降低噪声• 采用弹性密封,不使用密封垫,从而避免外泄漏的产生• 总效率高,功耗小,减小发热• 采用带无泄漏调节装的简单变量控制器 • 符合SAE 及ISO 标准的安装法兰及油口 • 采用圆锥滚柱轴承,使用寿命长 • 全功率后驱动能力• 后部或侧面油口配置可选• 泄油口的配置对水平安装及驱动轴向上垂直安装均适用• 带有最大及最小排量调节选项 • 具有壳体至吸口单向阀选项,可延长轴封寿命 • 使用、维修方便 脉动容腔技术下列图表所示为侧向油口配置P1/PD 18, 28及45泵采用 “脉动容腔” 技术的效果,脉动容腔可降低泵出口处的压力脉动幅值40-60%,这样,无需增加成本来加装噪声缓冲元件,便可大大降低液压系统的整体噪声,P1系列 PD 系列出口压力p / bar平均压力脉动 / b a rP1 045出口压力脉动2600 rpm 无脉动容腔2600 rpm 带脉动容腔订货代号18 ml, 28 ml, 45ml派克汉尼汾P 类型 01 驱动轴 转向R 5密封材料E 油口配置0 壳体-吸口 单向阀 0 排量调节 018 排量 S 安装法兰 及油口 S 轴封 M 应用范围A 设计系列0 通轴驱动选项 C0控制选项0附加控制选项 00油漆 00修改代号系列 P D * 仅适用于045排量, “S”型安装法兰及油口00 标准型, 无修改M2 按要求修改 代号修改代号 * 适用于028及045排量 ** 仅适用于045排量 代号设计系列 A 现行设计系列5 氟碳橡胶 (FPM) 代号密封材料 A 82-2 SAE A M33x2 M27x2 BSPP 1/4”, 3/8” 101-2 SAE B M42x2 M27x2 BSPP 1/4”, 1/2” 101-2SAE B M48x2M33x2Ø38/25DN51/25BSPP 1/4”, 1/2”B ISO M33x2 M27x2 BSPP 1/4”,3/8”ISO M42x2 M27x2 BSPP 1/4”, 1/2” ISO M48x2M33x2Ø38/25DN51/25BSPP 1/4”, 1/2”代号 018排量 028排量 045排量 安装法兰及油口 安装 法兰 螺纹 油口 辅助 油口 安装 法兰 螺纹 油口 辅助 油口 安装法兰螺纹油口法兰 油口辅助 油口 S 82-2 SAE A SAE 16/12 SAE 4/6 101-2 SAE B SAE 20/12 SAE 4/8 101-2SAE B SAE 24/16Ø38/2561系列SAE 4/10M ISO M33x2 M27x2 M12x1.5 M16x1.5 ISO M42x2 M27x2 M12x1.5 M22x1.5 ISO M48x2M33x2Ø38/25DN51/25M12x1.5M22x1.5代号 018驱动轴 028驱动轴 045驱动轴 01 SAE A 11T 花键SAE B-B 15T 花键 SAE B-B 15T 花键02 SAE 19-1平键Ø0.75” SAE B-B 平键Ø1” SAE B-B 平键Ø1” 08— SAE B 13T 花键 SAE B 13T 花键 04 ISO/DIN 平键, Ø20ISO/DIN 平键, Ø25ISO/DIN 平键, Ø25 06 SAE A 9T 花键— — PD 工业液压用 代号 系列P1 行走机械用 代号 排量 018 18 ml/rev (1.10 in 3/rev) 028 28 ml/rev (1.71 in 3/rev) 045 45 ml/rev (2.75 in 3/rev) 代号 类型 P 开式回路用变量柱塞泵 U*通用 代号应用范围 S 工业液压 (PD) M 行走机械 (P1) R 顺时针 (右转)L 逆时针 (左转)代号 转向 代号 轴封 S 单唇轴封 * 并不具有控制功能,仅在运输时予以防护,详情见第7页的控制说明。
Material specificationsBody Polyamide reinforced fiberglass End plates Aluminum Fasteners Zinc plated steel Manifolds AluminumSpoolBrass and nitrile rubber Spool enclosureBrassMost popular.For technical information see CDThis plug-in valve solution simplifies wiring with the use of 25 pin connectors or fieldbus systems.Ports• M7 on manifolds• 3/8 Inch on end platesMounting • ManifoldSolenoids• 24 VDC, 1.0 wattCertification / approval • IP65 rated• EMC / CE Mark: According to EN 61 000-6-2Manifolds can be configured for either internal or external pilot in the field. Side ported manifolds are configured for internal pilot when the M7 plug is located in the Px port on the front of the right hand end plate. Moving this plug to the inside of the right hand end plate and replacing it with a fitting allows an external pilot to be used.Bottom ported manifolds are configured for internal pilot when the M7 plug is located in the Px port on the bottom of the right hand end plate. Moving this plug to the inside of the right hand end plate and replacing it with a fitting allows an external pilot to be used.External PilotPx Internal PilotPx Internal PilotExternal Pilot3-positioncenter exhaustA traditional 5/3 center exhaust valve is now replaced by a double 3/2 NC+NC valve module. Both cylinder chambers piston are free to move.Dual 3/2 valves replace 3-position valves for better performance3-positionpressure center A traditional 5/3 pressure center valve is nowreplaced by a double 3/2 NO+NO valve module. The function is identical.Pilot configurationPlug-in valve manifolds Part numbers Side port Bottom port Single solenoid outputs onlyPSM21JAPPSM22JAP Double or single solenoid outputsPSM21MAPPSM22MAPIsys Micro ValvesSymbolTypeCv Operator Part numberInternal Pilot End Plate KitsElectrical option Porting Side port Bottom portSimple Manifold Assemblies** Requires fitting “P”.BOLD OPTIONS ARE MOST POPULAR.N 7D 1516Valve Position A - Character 9Fitting Position A - Character 10Valve Position C - Character 13Fitting Position C - Character 14Valve Position B - Character 11Fitting Position B - Character 12Valve Position D - Character 15Fitting Position D - Character 16ACDACDBBIncludes a valve manifold with 4 valves and fittings installed. End Plates must be ordered separately.1. List Add-A-Fold Assembly call out. This automatically includes the end plate kit assembly.2. List Simple Manifold Assemblies. List left to right, LOOkING AT ThE CyLINDER PORTS on the manifold.Maximum Number of Solenoids(Maximum Energized Simultaneously)25-pinD-sub Moduflex Isysnet*Turck16Outputs32Outputs 24VDC24 (24)16 (16)32 (32)16 (16)32 (32) * Maximum of 32 solenoids per manifold. With Bus Extension functionality,4 manifolds with up to 32 solenoids each can be connected on the same network.Add-A-Fold Assembly Model NumberHow To Order Plug-in Add-A-Fold AssembliesNote:BSPP fittings can only be used with BSPP Manifolds.NPT fittings can only be used with NPT Manifolds.Sandwich RegulatorFlow Controls2-position and Dual 3/2 valves, and 0.17 for 3-position APB valves.Note: The sandwich regulator passes full pilot pressure from the manifold,allowing the regulated pressure to adjusted down to 5 PSI without affecting valve functionality.25-pin, D-Sub ManifoldsComponent LevelItem Qty Description Part number 01125-pin, D-sub, end plate PSML25AP0224Single solenoid valveHMEVX2049A 036Manifold, side ported, single address PSM21JAP 04501/4" Tube fittings (in box quantity)PS56792505103/8" Tube fittings (in box quantity)PS5683380613/8" Exhaust muffler P6M-PAB30711/8" Exhaust mufflerP6M-PAB1Add-A-FoldManifold is factory assembled and tested for pneumatic leaks and electrical continuity.Item Qty Description Part number 01124 valve Add-A-Fold with end platesAAHMD5249M0M 0264 valve simple manifold slices #1-6PSM31JAPE7E7E7E725-pin, D-Sub Cable (Female)DescriptionLengthPart number25-pin, D-sub cable, IP20 3 meters P8LMH25M3A 25-pin, D-sub cable, IP209 meters SCD259D 25-pin, D-sub cable, IP65 3 meters SCD253W 25-pin, D-sub cable, IP659 meters SCD259WE24 Single Solenoid ValvesManifold Slice #1Manifold Slice #2Manifold Slice #3Manifold Slice #5Manifold Slice #4Manifold Slice #6MufflersFittings – Must be ordered in multiples of 10ThreadTube O.D.Part numberPSM0001 –All ports open. Common pressure for front and rear mon exhausts.Standard gasket included with each manifold and end plate.Back Row OpenCommon Front Row OpenPSM0001PSM0001PSM0002 –Rear manifold blocked for separate pressure mon exhausts.Flip gasket to block front of manifold.Back Row Blocked Common Front Row OpenPSM0002PSM0002Intermediate* Qty. (2) PSM0002 Gaskets are required.Remainder are PSM0001 Gaskets (Not shown)Internal Pilot Pressure from P1 InletPSM0003 –Rear manifold blocked for separate pressure supply.Exhaust blocked also.Flip gasket to block front of manifold.If used with bottom ported end plates, second exhaust must be piped from the side of the right end plate.Back Row Blocked Common Front Row OpenIntermediatePSM0003PSM0003PSM0002PSM0002* Qty. (1) PSM0003 and Qty. (1) PSM0002 Gaskets are required.Remainder are PSM0001 Gaskets (Not shown)Internal Pilot Pressure from P1 Inlet PSM0004 –All galleys blocked.Two pressure zones and two exhaust zones.If used with bottom ported end plates, second exhaust must be piped from the side of the right end plate.PressurePressureExhaustExhaustBack Row Blocked Common Front Row BlockedIntermediate * Qty. (1) PSM0004 Gasket is required.Remainder are PSM0001 Gaskets (Not shown)PSM0004PSM0001PSM0004PSM0001Internal Pilot Pressure from P2 InletMultiple Pressure ZonesReplacement ScrewsManifold to Manifold Gaskets*Valve Labels*Replacement Solenoid Kit Replacement Override Caps Replacement Regulator GaugeReplacement Protective CoverReplacement Gaskets and Valve ScrewsReplacement PlugsDescription Part numberDimensionsA 4.88 (124.0)B 4.41 (112.0)C 2.95 (75.0)D 1.65 (42.0)E 1.22 (31.0)F 1.02 (26.0)G 0.71 (18.0)H 0.49 (12.5)J 2.28 (58.0)K 3.44 (87.5)M 0.24 (6.1)N 0.21 (5.2)P 0.41 (10.5)per ManifoldBottom PortedDetail25-pin, D-Sub with Isys Micro Valves, Bottom Ported25-pin, D-Sub with Isys Micro Valves, Side PortedInches (mm)Inches (mm)per ManifoldSide Portedn = Number of manifoldsn = Number of manifoldsDimensionsA 4.88 (124.0)B 4.41 (112.0)C 2.95 (75.0)D 1.65 (42.0)E 1.22 (31.0)F 1.02 (26.0)G 0.71 (18.0)H 0.49 (12.5)J 2.28 (58.0)K 3.44 (87.5)L 1.69 (43.0)M 0.24 (6.1)N 0.21 (5.3)P 0.62 (15.8)Q 1.03 (26.3)R 1.45 (36.8)S 0.64 (16.40)T 1.14 (29.0)U 3.73 (94.9)V 4.23 (107.4)Isysnet with Isys Micro Valves, Bottom PortedDimensionsA 5.67 (144.0)A 14.88 (124.0)B 4.41 (112.0)B 15.24 (133.0)B 24.02 (102.0)C 2.95 (75.0)D 1.65 (42.0)E 0.91 (23.0)G 0.71 (18.0)H 0.49 (12.5)J 2.72 (69.0)K 7.32 (186.0)M 0.24 (6.1)N 2.83 (72.0)Q 1.81 (46.0)R 4.72 (120.0)S 2.01 (51.0)T 2.01 (51.0)DimensionsA 5.67 (144.0)A 14.88 (124.0)B 4.41 (112.0)B 15.24 (133.0)B 24.02 (102.0)C 2.95 (75.0)D 1.65 (42.0)E 0.91 (23.0)G 0.71 (18.0)H 0.49 (12.5)J 2.72 (69.0)K 7.32 (186.0)L 1.69 (43.0)M 0.24 (6.1)N 2.83 (72.0)Q 1.81 (46.0)R 4.72 (120.0)S 2.01 (51.0)T 2.01 (51.0)U 4.41(112)per ManifoldInches (mm)Inches (mm)n = Number of Manifolds m = Number of Modulesn = Number of Manifolds m = Number of ModulesModuflex with Isys Micro Valves, Bottom Ported0.25 (6.4) per Manifold0.25 (6.4) DimensionsA 4.88 (124.0)B 4.41 (112.0)C 2.95 (75.0)D 1.65 (42.0)E 1.22 (31.0)F 1.02 (26.0)G 0.71 (18.0)H 0.49 (12.5)J 2.28 (58.0)K 6.10 (155.0)L 1.69 (43.0)M 0.24 (6.1)N 2.40 (61.0)P 2.36 (60.0)Q 2.07 (52.55)Inches (mm)Inches (mm)n = Number of manifoldsn = Number of manifoldsDimensionsA 4.88 (124.0)B 4.41 (112.0)C 2.95 (75.0)D 1.65 (42.0)E 1.22 (31.0)F 1.28 (32.5)G 0.71 (18.0)H 0.49 (12.5)J 2.28 (58.0)K 6.10 (155.0)M 0.24 (6.1)N 2.40 (61.0)P 2.36 (60.0)Q 2.07 (52.55)Catalog PDN1000-2US Parker PneumaticParker Hannifin Corporation Pneumatic Division Richland, Michigan /pneumaticsD123Valve Products Isys Micro Series Dimensions Turck with Isys Micro Valves, Side PortedDimensions A 7.48 (190)B 5.51 (140)C 5.71 (145)D 0.20 (5)F 1.28 (32.5)G 3.79 (96.5)H 5.06 (128.5)J 2.53 (64.5)K 1.26 (32)L 2.54 (64)M See note 1N 2.28 (58)P 1.65 (42)Q .19 (4.9)R 4.41 (112)S 4.88 (124)Note 1: M =J+L+n 2xk, where n 2 = Number of Turck input / output modules Inches (mm)。
P1D系列parker气缸
万星耀科技(深圳)有限公司成立于2009年3月,是世界500强企业Parker Hannifin的国内重要分销商,主要代理Parker 的液压元件、液压成套、流体连接件、密封件以及过滤设备等自动化和过程控制产品,且拥有丰富的液压系统测试、调试和加工能力。
我们提供的服务
∙性能可靠、种类齐全的parker流体传动产品
∙完善、安心的售后与现场服务
∙优质、专业的技术咨询服务
P1D-T系列缸径从Ø32到Ø125mm是拉杆结构符合ISO 15552 / VDMA标准的气动直线气缸。
精心的设计,优质的材料,高质量的制造,保证了较长的使用寿命。
在标准配置的P1D-T系列,可选用不锈钢活塞杆,气动缓冲,耐
腐蚀的缸筒和内置的可供位置检测的带磁环的活塞,在标准温度范围为-20°C 到+ 80°C,这个系列的拉杆气缸可用于广泛的应用场合。
在严格的环境中遇到的挑战需要领先的工程解决方案和产品。
为满足这些要求,符合ISO 15552标准的P1D-T系列气缸,提供了高温和低温应用的方案。
使用经过验证的性能领先的密封技术,工程技术方案可保证产品在恶劣条件下优越的性能,确保产品在温度低到-40°C和高到+ 150°C 的条件下运行可靠,使用寿命长。
采用坚固耐腐蚀的金属缸筒拉杆结构,聚四氟乙烯涂层钢支撑环和可选金属刮尘圈的P1D-T系列,缸径尺寸可以从32至125mm,并可提供符合 ISO标准的全系列安装附件
通用技术参数
• 国际标准 : 符合 ISO 15552, ISO 6431, VDMA 24562 和 AFNOR安装尺寸标准.
• 缸径尺寸: Ø32, Ø40, Ø50, Ø63, Ø80, Ø100 和Ø125 mm
• 行程长度 : 10到 2800mm
• 版本 : 双作用/双作用双出杆/3和4位/串联
• 缓冲 : 可调气缓冲
• 位置检测 :使用传感器安装支架可以很简便的把传感器安装在气缸行程范围内的任何位置。
可选电子式或舌簧片式传感器,电缆长度可选,还可选8 mm 夹子,M12 插头或直接出线连接。
低温版本的气缸活塞有磁环以用于位置检
测(但请注意,传感器通常性能参数只适用于最低到-25°C的温度。
)高温版本的气缸活塞不带磁环所以不能使用传感器
安装
• 安装 : 大范围的阳极氧化铝气缸安装附件可提供相同的整体耐腐蚀性• 安装位置 : 任意位置
工作温度 :
• 标准温度: -20°C到+80°C
• 低温: -40°C到+80°C
• 高温:-10°C到+150°C
• 低压液压油版本: -20°C到+80°C
•金属刮尘圈版本: -30°C到+80°C
技术规格:
油缸类型:Non-Guided、Guided、Through Rod、Extended Piston Rod、3 and 4 Position、Tandem
油缸动作:Double Acting
通孔尺寸:32mm、40mm、50mm、63mm、80mm、100mm、125mm
最大冲程(毫米):2800
最大冲程(英寸):110.2
延长的冲程推力(牛顿):483 to 7363 (at 6 bar)
收回冲程推力(N):415 to 6881 (at 6 bar)
缓冲类型:Pneumatic Adjustable
端口尺寸:G1/8、G1/4、G3/8、G1/2
杆端螺纹类型:Male、Female
最大工作压力(BAR):10
最大工作压力(PSI):145
运行环境温度(C)
-40 TO +80 (LOW)
-20 TO +80 (STANDARD)
-10 TO +150 (HIGH)
-20 TO +80 (LOW PRESSURE HYDRAULIC)
-30 TO +80 (METAL SCRAPER)
运行环境温度(C)
-40 TO +176 (LOW)
-4 TO +176 (STANDARD)
+14 TO +302 (HIGH)
-4 TO +176 (LOW PRESSURE HYDRAULIC)
-22 TO +176 (METAL SCRAPER)
遥感位置:OPTIONAL BRACKET
装配选择:YES - ISO 15552
证书:ISO 15552
活塞杆材料
STAINLESS STEEL
CHROME PLATED STEEL
ACID PROOF STEEL
CHROME PLATED STAINLESS STEEL
阀体材料:ALUMINIUM
后盖材料:ALUMINIUM
公司秉承“以人为本,以德治业,诚信守用,互惠双赢”的经营理念,坚持“以客户为中心,以市场为向导,以质量求发展,以服务求市场”的经营方针,用性能可靠的优质产品,专业的工程技术,优秀的销售团队,完善的售后服务,坚持实施品牌战略和客户满意工程,在行业内外树立了良好的信誉。
详情可查:。