道康宁7355说明书
- 格式:pdf
- 大小:109.29 KB
- 文档页数:3
byk3605流平剂说明书
产品信息:用于改善溶剂型和无溶剂型辐射固化体系抗划伤和耐磨性能的纳米颗粒分散体。
保质期(月):18(按照产品文件所规定的条件储存在未开封的原始包装中)
化学组成:表面处理的二氧化硅纳米颗粒分散体。
典型物化数据:密度(20°C):1.39g/ml
载体:己二醇二丙烯酸酯(HDDA)
闪点:79℃
纳米颗粒含量:50%
颗粒粒径D50:20nm
贮存和运输:15℃到40℃之间贮存和运输,避免阳光直射,该助剂对湿度敏感,贮存和运输过程中可能发生浑浊和分层,使用前请混合均匀。
应用领域:涂料工业
特性和优点:该助剂可以提高抗划伤和耐磨性能并且不影响光泽和透明性,同时还可以提高耐化学性。
该助剂特别推荐用于无溶剂和溶剂型辐射固化木器和家具涂料以及工业涂料。
建议用量:1~10%助剂用量(供应形式)基于总配方助剂的用量取决于涂层的厚度,厚涂层可以相应的减少助剂用量。
在大多数情况下1~4%用量是足够的,如果有苛刻的抗划伤需求,用量可以提高到20%。
加入方法及加工指导:为获得性能,产品应在低剪切力下加入,这样可以确保助剂均匀分散到基料体系中。
我们推荐可以与提高表面滑爽的助剂搭配使用。
特别提醒:该产品使用前搅拌均匀。
由于干结的物料会引起涂料起粒,所以在加料前先除去容器表面的干结物料。
Information About Dow Corning ® brand Adhesive/SealantsSilicones and ElectronicsLong-term, reliable protection of sensitive circuits and components is important in many of today’s delicate and demanding electronic applications. Silicones function as durable dielectric insulation, as barriers against environmental contaminants and as stress-relieving shock and vibration absorbers over a wide temperature and humidity range.In addition to sustaining their physical and electrical prop-erties over a broad range of operating conditions, silicones are resistant to ozone and ultraviolet degradation, have good chemical stability and are available in a variety of useful forms as conformal coatings, encapsulants and adhesives.Dow Corning’s broad range of general purpose and specialty products offers you a choice of materials for your application needs.Dow Corning offers a variety of noncorrosive silicone products for electronic sealing, bonding and adhering applications. These adhesives generally fall into three cure types. The first group are moisture cure, generally meant for room-temperature processing. The second type(condensation cure) offers rapid room-temperature and deep-section curing. The third type is heat cure for rapid processing. All convert to durable, relatively low stresselastomers. Most will develop good, primerless adhesion to a variety of common substrates including ceramics, reactive metals and filled plastics.TYPICAL PROPERTIESThese values are not intended for use in preparing specifications.Specification Writers: Please obtain copies of the Dow Corning Sales Specifications for these products and use them as a basis for your specifications. They may be obtained from any Dow Corning Sales Office, or from Dow Corning Customer Service in Midland,MI. Call (517) 496-6000.HEAT CURE TIMESCURE CONDITIONSOne-Part Moisture Cure RTVThe one-part moisture cure adhesives (838, 839, 3165, 3145,3140 and 3-1744) are generally cured at room temperature and in a range of 30 to 80 percent relative humidity. Greater than 90 percent of their full physical properties should be attained within 24 to 72 hours depending on the product chosen. Materials and parts can be handled in much shorter times of about 10 to 120 minutes depending on the product chosen and the amount of material used per part. These materials are not typically used for highly confined or deep section cures. Materials will generally cure about 0.25 inch per seven days from any exposed surface. Cure progresses from the outer surface and is dependent on the moisture in the air. Working time is generally a few minutes to an hour for these products until a surface skin begins to form. Mild heat acceleration of the cure rate may be possible but temperatures above 60°C (140°F) are not recommended.Two-Part Room Temperature Condensation CureDow Corning ® Q3-6093 Silicone Adhesive is the only two-part condensation curing product. Once mixed, cure progresses rapidly at room temperature. Good strength is attained within an hour but full properties are not reached for anumber of days. Q3-6093 adhesive contains its own source of moisture and cure progresses evenly throughout the material.Deep section or confined cures are possible however (see “Reversion”). Working time is only a few minutes.Heat CureThe addition curing adhesives (577, 3-6876, 3-6611 and 3-6265) should be cured at 100°C (212°F) or above. The cure rate is rapidly accelerated with heat (see cure schedulesin table). For thicker sections or if voiding is observed, a 30 minutes pre-cure at 70°C (158°F) may reduce voids in the elastomer. Addition-curing materials contain all the ingredients needed for cure with no byproducts from the cure mechanism. Deep section or confined cures arepossible. Cure progresses evenly throughout the material.These adhesives generally have long working times.PREPARING SURFACESAll surfaces should be thoroughly cleaned and/or degreased with Dow Corning ®brand OS Fluids, naphtha, mineral spirits,methyl ethyl ketone (MEK) or other suitable solvent.Solvents such as acetone or isopropyl alcohol (IPA) do not tend to remove oils well, and any oils remaining on the surface may interfere with adhesion. Light surface abrasion is recommended whenever possible, because it promotes good cleaning and increases the surface area for bonding. A final surface wipe with acetone or IPA is also useful.Different cleaning techniques may give better results than others. Users should determine the best techniques for their applications.ADHESIONDow Corning silicone adhesives are specially formulated to provide unprimed adhesion to many reactive metals,ceramics and glass, as well as to selected laminates, resins and plastics. However, good adhesion cannot be expected on nonreactive metal substrates or non-reactive plastic surfaces such as Teflon ®, polyethylene or polypropylene. Special surface treatments such as chemical etching or plasma treatment can sometimes provide a reactive surface and promote adhesion to these types of substrates. Dow Corning ®brand primers (see “Primer Selection Guide”) can be used to increase the chemical activity on difficult substrates.2P5200 Red is a low-VOC alternative to 1200 Red.3P5204 is a low-VOC alternative to 1204.4The lower VOC value is for states and air quality management districts that have recognized volatile methylsiloxanes as VOC exempt.PRIMER SELECTION GUIDEThese values are not intended for use in preparing specifications.Poor adhesion may be experienced on plastic or rubber substrates that are highly plasticized, because the mobile plasticizers act as release agents. Small-scale laboratory evaluation of all substrates is recommended before production trials are made.In general, increasing the cure temperature and/or cure time will improve the ultimate adhesion.SUBSTRATE TESTINGDue to the wide variety of substrate types and differences in substrate surface conditions, general statements on adhesion and bond strength are impossible. To ensure maximum bond strength on a particular substrate, 100 percent cohesive failure of the adhesive in a lap shear or similar adhesive strength test is desired. This ensures compatibility of the adhesive with the substrate being considered. Also,this test can be used to determine minimum cure time or can detect the presence of surface contaminants such as mold release agents, oils, greases and oxide films.USEFUL TEMPERATURE RANGESFor most uses, silicone elastomers should be operational over a temperature range of -45 to 200°C (-49 to 392°F) for long periods of time. However, at both the low and high temperature ends of the spectrum, behavior of the materials and performance in particular applications can become more complex and require additional considerations.For low-temperature performance, thermal cycling to conditions such as -55°C (-67°F) may be possible, butperformance should be verified for your parts or assemblies.Factors that may influence performance are configuration and stress sensitivity of components, cooling rates and hold times, and prior temperature history.At the high-temperture end, the durability of the cured silicone elastomer is time and temperature dependent. As expected, the higher the temperature, the shorter the time the material will remain useable.COMPATIBILITYCertain materials, chemicals, curing agents and plasticizers can inhibit the cure of addition cure adhesives. Most notable of these include:•Organotin and other organometallic compounds •Silicone rubber containing organotin catalyst •Sulfur, polysulfides, polysulfones or other sulfur-containing materials•Amines, urethanes or amine-containing materials •Unsaturated hydrocarbon plasticizers •Some solder flux residuesIf a substrate or material is questionable with respect to potentially causing inhibition of cure, it is recommended that a small scale compatibility test be run to ascertain suitability in a given application. The presence of liquid or uncured product at the interface between the questionable substrate and the cured gel indicates incompatibility and inhibition of cure.MIXING AND DE-AIRINGUpon standing, some filler may settle to the bottom of the liquid containers after several weeks. To ensure a uniform product mix, the material in each container should be thoroughly mixed prior to use.1Clear only.2Gray only.3UL746C Approved.LISTINGS AND SPECIFICATIONSDow Corning Corporation Midland, Michigan 48686-0994Dow Corning and Sylgard are registered trademarks of Dow Corning Corporation.Teflon is a registered trademark of E.I. du Pont de Nemours Co.©2000 Dow Corning Corporation. All rights reser ved.Printed in USAAGP4781Form No. 10-911A-01Two-part materials should be mixed in the proper ratio (1:1or 10:1) either by weight or volume. The presence of light colored streaks or marbling indicates inadequate mixing.Automated airless dispense equipment can be used toreduce or avoid the need to de-air. If de-airing is required to reduce voids in the cured elastomer, consider a vacuum de-air schedule of >28 inches Hg for 10 minutes or until bubbling subsides.REVERSIONWhen two-part condensation curing materials with organo-tin catalysts, such as Q3-6093 adhesive, are cured in confinement (especially in deep section) and are later subjected to high heat conditions, can potentially revert back from a cured elastomer to a flowable polymer.Although this condition is unusual, parts using Q3-6093adhesive should be thoroughly tested in accelerated temperature conditions for this potential limitation.SOLVENT EXPOSUREWhen liquid or vapor solvent or fuel exposure can occur in an application, the silicone adhesives discussed in thisbrochure are intended only to survive splash or intermittent exposures. They are not suited for continuous solvent or fuel exposure. Testing should be done to confirm performance of the adhesives under these conditions.STORAGE AND SHELF LIFEShelf life is indicated by the “Use Before” date found on the product label.For best results, Dow Corning RTV adhesives should be stored at or below 25°C (77°F). Special precautions must be taken to prevent moisture from contacting these materials.Containers should be kept tightly closed and head or air space minimized. Partially filled containers should be purged with dry air or other gases, such as nitrogen.Dow Corning heat-cure adhesives should also be stored at or below 25°C (77°C). Containers should be kept tightly closed and kept in cold storage at all times to extend shelf life.LIMITATIONSThese products are neither tested nor represented as suitable for medical or pharmaceutical uses.PACKAGINGIn general, Dow Corning adhesives/sealants are supplied in nominal 0.45-, 3.6-, 18- and 200-kg (1-, 8-, 40- and 440-lb)containers,net weight. Not all products may be available in all packages and some additional packages, such as a bladder packs or tubes, may be available for certain coatings and package sizes.SAFE HANDLING INFORMATIONPRODUCT SAFETY INFORMATION REQUIRED FOR SAFE USE IS NOT INCLUDED. BEFORE HANDLING,READ PRODUCT AND MATERIAL SAFETY DATA SHEETS AND CONTAINER LABELS FOR SAFE USE, PHYSICAL AND HEALTH HAZARD INFORMATION. THE MATERIAL SAFETY DATA SHEET IS AVAILABLE FROM YOURDOW CORNING REPRESENTATIVE, OR DISTRIBUTOR,OR BY WRITING TO DOW CORNING CUSTOMER SERVICE, OR BY CALLING (517) 496-6000.WARRANTY INFORMATION – PLEASE READ CAREFULLYThe information contained herein is offered in good faith and is believed to be accurate. However, because conditions and methods of use of our products are beyond our control,this information should not be used in substitution for customer’s tests to ensure that Dow Corning’s products are safe, effective, and fully satisfactory for the intended end use. Dow Corning’s sole warranty is that the product will meet the Dow Corning sales specifications in effect at the time of shipment. Your exclusive remedy for breach of such warranty is limited to refund of purchase price or replace-ment of any product shown to be other than as warranted.Dow Corning specifically disclaims any other express or implied warranty of fitness for a particular purpose or merch-antability. Unless Dow Corning provides you with a specific,duly signed endorsement of fitness for use, Dow Corning disclaims liability for any incidental or consequential damages.Suggestions of uses should not be taken as inducements to infringe any particular patent.。
微孔过滤器ZG-10.0使用说明书制作单位:生产基地:公司电话:公司传真:邮 编:编制日期:目录一、 产品介绍 (3)二、产品特点 (3)三、滤芯的选择 (3)四、设备技术参数 (4)五、使用说明 (4)六、操作注意事项 (6)七、设备的维护与保养 (6)八、售后服务承诺 (7)九、合格证 (7)十、随机附件表 (8)一、产品介绍:本设备可用于食品、乳品、饮料、酒类、中药、化工行业的液体物料的气体的过滤。
采用折叠式滤芯,折叠式滤芯是一种先进的固定型深层过滤芯,过滤公称精度范围可以从0.1μm直600.1μm。
滤膜不受进料压力波动而影响过滤精度。
其特有的低压差,高通量、良好的过滤精度能较低的经济费用成为取代线绕式、棉饼和纸板等非固定型过滤芯的新型滤芯而深受用户欢迎。
二、产品特点:①化学相容性广、流通量大、压差低、使用寿命长。
②过滤精度范围广、选择度大、可满足各种应用场合。
③采用热熔工艺,牢固且无释放物污染产品。
三、滤芯的选择:1、滤芯的用途很广泛,滤芯的品种、规格较多,选择型号是很重要的。
根据用途可分为过滤液体和气体二种,规格大小可以分为5〃、10〃、20〃、30〃和40〃等。
工作压力一般在0.1Mpa—0.4 Mpa。
由于滤芯孔径不同,其流量也不尽相同,如0.2um—0.4 um过滤沌水的标准在300—500kg/h,如果要提高每小时的过滤量,则可以用多芯或20〃、30〃、40〃英寸组合,例如要过滤5t/h的无菌水,则可以选用0.2 um,30英寸7芯的过滤器。
若过滤杂质多且有粘度,则应添加前置预过滤设备。
气体的过滤与液体过滤稍有不同,它的过滤量以每分钟立方气体来计算。
10英寸滤芯,孔径φ0.22 um,压力在0.12 Mpa,压差在0.01 Mpa时,流量为4-6m3/min,在发酵工业上广泛应用。
2 、合适的滤芯,选用适当的孔径,若要除菌则选用0.2um-0.5um孔径的滤芯、药用针剂、抗菌素、血制品等用聚砜滤芯。
过滤、洗涤、干燥机<罐式三合一)产品使用说明书温州亚光机械制造有限公司一、设备用途LXG型过滤、洗涤、干燥机<又称罐式三合一),广泛用于制药、化工、农药、食品等行业的固液分离、固体洗涤、固体干燥和固体卸料可实现全过程为封闭的连续操作,是上述行业过滤洗涤干燥首选设备。
二、设备结构简介该设备为不锈钢制立式容器,由罐体装置、搅拌装置、轴端密封装置、升降机构、液压装置、罐底座<固定或可拆式)、加热装置、传动机构、过滤装置、卸料装置、取样装置、洗涤<清洗)灭菌装置、行程指示装置、触摸屏与手动操作控制装置、液压泵站、主电控柜<包括变频器、CPU等),及其它电器附件等部件组成。
实现机、电、仪一体化。
三、设备工艺特点在同一容器内完成过滤、洗涤、干燥全过程连续操作。
1.过滤:在加压或真空状态下操作,实现固液分离。
过滤时滤饼平整,固液分离效果好。
2.洗涤:在容易内侧装有特制360°旋转喷淋装置,使清洗<洗涤)液均匀分布于容器内,可实现容器内部清洗和物料桨化洗涤。
通过升降桨叶搅拌将滤饼和洗涤液混合,使浆状结晶及滤饼得到充分洗涤。
3.干燥:滤饼被搅拌桨叶逐层刮松,设备加热装置均匀对滤饼加热,在真空状态下用热气体对湿物料加热,加速蒸发,达到干燥目的。
4.取样:滤饼干燥适当时间后,进行在线取样分析滤饼湿份,达到产品内控质量要求,即可冷却,为卸料作准备。
5.卸料:刮松物料,通过搅拌叶推动从罐壁侧面出料口自动卸料。
四、设备技术参数及规格1.技术参数:.注:过滤烧结板规格:5μm、10μm、15μm、20μm、25μm、30μm、40μm<由用户工艺选用)2、设备规格2.1LXG××─×W型过滤洗涤干燥机<无菌型)规格:2.2LXG××─×型过滤洗涤干燥机<工业原料型)规格:注:其它设备规格可根据用户工艺要求设计非标准型号2.3管口设置清洗口、洗涤<sip)口、气体进口、捕集器真空口、反吹口、平衡口、温度计口、取样口、出料口、零压口、压力表口、放空口、手孔<人孔)、视镜口、灯镜口、滤液口、加热<冷却)口等。
How to OrderOptionOptionPiping direction Part no.Bracket Panel mountPanel mount + Front protection coverRear portedRear portedBottom ported Rear portedBottom ported Rear portedBottom portedZS-24-A ZS-24-D ZS-35-A ZS-35-C ZS-35-B ZS-35-F ZS-35-EFor vacuum/compound pressureFor positive pressure 80ISE 02N 80ZSE 02N –0.1 to 1 MPa –0.1 to 2 MPaRated pressure range8080H 0 to –101 kPa –100 to 100 kPaRated pressure range8080FNPN open collector 1 output PNP open collector 1 output NPN open collector 2 outputs PNP open collector 2 outputsNPN open collector 2 outputs + Analog voltage output/Auto-shift switching PNP open collector 2 outputs + Analog voltage output/Auto-shift switching NPN open collector 2 outputs + Analog current output/Auto-shift switching PNP open collector 2 outputs + Analog current output/Auto-shift switchingInput/OutputN P A B R T S VNote) Fixed unit ISE80H: MPaOthers : MPa, kPaWith unit display switching function Fixed SI unit Note)Initial value psiOption 1NilMPOption 3Note) All texts in both English and JapaneseOperating Note)manual b (Booklet)—b (CD-ROM)Calibration certificate ———Nil Symbol YWb (Booklet)—b (CD-ROM)Calibrationcertificateb b b Symbol K T R PipingR1/4(M5 female threaded)Rear portedBottom portedNPT1/4(M5 female threaded)G1/4(M5 female threaded)Rc1/8URJ1/4TSJ1/402N02F02R1/4(M5 female threaded)NPT1/4(M5 female threaded)Rc1/8URJ1/4TSJ1/402LN02L C01A2B2C01L A2L B2LNoneWith bracketRear portedBottom portedBottom portedOption 2NilABPanel mountWith bracket Note)Rear portedBottom portedPanel mount + Front protection coverRear portedCDNote) Rear ported onlyTable 1Made to OrderNote) Not applicable to the rated pressure range 0 to 2MPa specification. Refer to page 743 for detail.Wetted parts: Stainless steel 316L Lead wire length 3 m Restrictor installed fittingSymbolSpecifications-X500 Note)-X501-X510ZS-24-AZS-35-AZS-24-DZS-35-CZS-35-BZS-35-FZS-35-EM MMade to OrderRefer to Table 1 below.Operating Note)manual ®2-Color Display Digital Pressure Switch For General FluidsSeries ZSE80/ISE80732。
24G15N安全 (1)标志惯例 (1)电源 (2)安装 (3)清洁 (4)其它 (5)设置 (6)物品清单 (6)安装支架和底座 (7)调整视角 (8)连接显示器 (9)Adaptive-Sync功能 (10)HDR (11)调节显示器 (12)热键 (12)OSD设定 (13)Luminance(明亮度) (14)Color Setup(颜色设置) (15)Picture Boost(窗口增亮) (16)OSD Setup(OSD设置) (17)Game Setting(游戏设置) (18)Extra(其它) (19)Exit(退出) (20)LED指示灯 (21)故障排除 (22)规格 (23)主要规格 (23)预设显示模式 (24)引脚分配 (25)即插即用版权说明.................................................................................................................................................................. ..................................................................................................................................................................2626安全标志惯例以下小节描述此文档中使用的标志惯例。
注释、注意和警告在本指南中,文本块可能带有图标并且以粗体或斜体打印。
这些文本块是注释、注意和警告,如下所示:注释:注意事项指示帮助你更好地使用你的计算机系统的重要信息。
注意:“注意”表示潜在的硬件损坏或数据丢失,并告诉您如何避免出现问题。
《CTA 系列高精度互感器说明书》前 言首先,感谢您购买该产品。
为了你安全正确地使用本产品,请先仔细阅读说明书。
这份产品使用说明书是关于该产品的功能、使用方法、操作注意事项等方面的介绍。
说明书中,注释将用以下的符号进行区分。
为安全使用本机器必须严格遵守以下安全注意事项。
如果不按照该说明书使用的话,有可能会损害机器的保护功能。
此外,因违反注意事项进行操作所产生的问题,本公司概不负责。
● 为避免短路及人身事故,被测电路要求在安全电压范围内使用。
● 机器潮湿,或用湿手测定的话,会发生触电事故,请注意。
● 搬运和操作时,避免振动、冲击。
特别是落下后产生的冲击。
● 避免阳光直射、高温、潮湿、结露的环境下保存和使用,会导致变形、绝缘恶化,不能满足使用规格。
● 使用前,请检查是否有由于苛刻的保存条件和运输等产生的产品故障,当确认故障时,请联系附近的代该符号表示对人体和机器有危害,必须参照说明书操作。
注意警告在错误操作的情况下,用户有受伤的威胁,为避免此类危险,记载了相关的注意事项。
错误操作时,用户有受轻伤和物质损害的可能,为避免此类情况,记载的注意事项。
该符号表示对人体和机器有危害,必须参照说明书操作。
Note记载着使用该机器时的重要说明。
注意警告理店或运营商。
本机器没有防水、防尘构造,请不要在灰尘多和易浸水的环境中使用。
CTA系列简要说明目录前言 (1)CTA系列简要说明 (2)概述 (4)应用 (4)产品及选件说明 (4)产品说明 (4)选件说明 (5)产品规格 (6)使用说明 (8)过载保护说明 (8)Status/Interlock端口连接说明 (9)操作方法 (10)机械规格 (11)环境特性 (12)装箱单 (12)1. 概述CTA系列是一款能够同时测量直流和交流的超高精度互感器。
电流范围从60A到1000A;精度高达0.03%;带宽最高达到800kHz。
利用磁通门技术实现高精度测量,优越的线性特性,极低的直流偏移,低温漂特性,低插入损耗,强抗干扰性能,低噪声等特点,非常适合高精度高稳定性的电流测量,广泛应用于工业,医疗,实验室等场合。
solo5遥控器说明书摘要:一、前言二、solo5遥控器概述1.产品简介2.产品功能三、solo5遥控器使用说明1.准备工作2.遥控器按键功能介绍3.遥控器与设备的配对与连接4.遥控器使用示例四、solo5遥控器注意事项1.使用环境2.维护保养3.安全提示五、附录1.技术参数2.常见问题解答3.售后服务正文:【前言】solo5遥控器是一款功能强大、操作简便的遥控器产品,适用于各种智能设备。
本说明书将详细介绍solo5遥控器的使用方法及注意事项,帮助用户更好地了解和使用该产品。
【solo5遥控器概述】【产品简介】solo5遥控器采用了先进的无线通信技术,支持多种设备,包括电视、空调、投影仪等。
用户可以通过遥控器轻松实现设备的遥控操作,提高生活品质。
【产品功能】solo5遥控器具备以下主要功能:1.无线遥控:采用2.4GHz无线通信技术,信号稳定,遥控距离远;2.多设备兼容:支持多种品牌和型号的设备;3.学习功能:可以学习并记忆设备的遥控指令,实现一键遥控;4.节能环保:低功耗设计,使用电池寿命长;5.操作简便:按键布局合理,操作直观。
【solo5遥控器使用说明】【准备工作】1.确保遥控器已充满电;2.确保目标设备已开启并处于待机状态。
【遥控器按键功能介绍】1.电源键:开关机及确认操作;2.方向键:上下左右方向控制;3.功能键:实现设备的特定功能,如音量调节、频道切换等;4.学习键:用于学习设备遥控指令的快捷键;5.菜单键:进入设备菜单界面。
【遥控器与设备的配对与连接】1.打开遥控器电源开关;2.按下遥控器上对应设备品牌或型号的快捷键,如“TV”、“AUX”等;3.观察目标设备,找到遥控器发射的红外信号并对其进行接收;4.设备收到信号后,按照屏幕提示完成配对或连接。
【遥控器使用示例】以电视遥控为例:1.按下遥控器上的“TV”键,使遥控器进入电视遥控模式;2.使用方向键切换频道,使用功能键调节音量;3.若要实现更多功能,可按下“学习”键,学习并记忆电视遥控指令;4.操作完成后,按下遥控器上的“电源”键,关闭遥控器电源。
道康宁993产品说明特性· 符合欧洲行业标准ETAG 002、中国GB-16776性能标准· 对广泛的幕墙基材包括镀膜,彩釉玻璃,阳极氧化和喷涂铝材以及不锈钢等金属材料均具有卓越的粘结性· 高标准的机械物理性· 中性固化无毒且无腐蚀性· 优越的耐高低温性-50oC至1 5 0 oC 优异的结构性强度(完全固化后)· 固化后的弹性具优秀的耐候特征及优良的抗紫外线,耐高温及湿度性能· 无批号配套限制· 中性脱醇型固化,固化于室温下会散发少量乙醇。
· 结构性应用需提前将材料品及图纸送交道康宁测试及审核·应用道康宁993N结构性装配用硅酮结构密封胶设计用于结构性应用,例如在工厂装配的玻璃与金属材料间的粘结,固化后形成耐久,具弹性及防水效果的结构性密封层。
·产品说明道康宁993N结构性装配硅酮密封胶为一种双组份,中性固化、适用于建筑幕墙用的高性能硅酮密封胶。
·性能数据道康宁993N结构性装配硅酮密封胶在无需底涂液的情况下对绝大多数的建筑基材均具有优良的粘结性能,其典型物理特性更适应于广泛的温度范围。
在经过欧盟技术委员会(EOTA)技术指南中规定的老化测试之后,仍展示了其持久的优良粘着性和机械性能:· 1000小时浸热水紫外光照射· 1000小时浸热水紫外光照射(ISO DIS 11431)·5000次循环剪切及拉伸试验·抗盐水喷射(ISO 9227 NSS)·抗SO2(ISO 3231)·抗清洁剂(ISO 8339)·抗极高低温(ISO 8339)·抗微有机体(ISO 846)·材料相容性说明道康宁993N结构胶对大多数镀膜及非镀膜玻璃和金属均无需底涂液且具优越的粘结性。
此结构胶与其它道康宁中性固化产品相容,包括道康宁995,795,791等以及道康宁中空玻璃密封胶和大多数常见的施工附属材料。