• C at. Nos. DOS05 and DVS05 have a sensing angle of 180° and a sensing area of coverage of 30 x 30 ft. See coverage diagram for details.• A djustable ambient light (DOS05 only), time delay and area of coverage controls. See adjustment setting section for details.• Indicator light alerts the user of device status.• A djustable time delay setting for 1, 5, 10 and 20 minutes plus a test mode with 5 seconds on. A Temporary Bypass mode that disables the Auto-on feature is available only for DOS05.Single Pole and 3 Way with 3-Way Switch ApplicationWide View Motion Activated Light ControlCat. Nos. DOS05, DVS05 - INDOOR USE ONLYRatings: 120VAC, 60Hz 600 W Incandescent, 5 A Resistive, 300W LED and CFL, 400 VA ELV/MLV, 1/4 HP MotorPK-A3346-10-00-2A-X4WARNINGS• TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!• TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, or a load in excess of the specified rating.• To be installed and/or used in accordance with electrical codes and regulations.• If you are not sure about any part of these instructions, consult an electrician.CAUTIONS• To clean use a damp cloth with mild soap. DO NOT use disinfecting products, including foggers, sprays or other types of atomized cleaning agents.• No user serviceable components. DO NOT attempt to service or repair.• Use this device WITH COPPER CLAD WIRE ONLY .InstallationWARNING: TO AVOID FIRE, SHOCK OR DEATH, turn off power at circuit breaker or fuse and test that the power is off before wiring.1. I dentify your wires (most common):You Will Need:• Slotted/Phillips screwdriver • Electrical tape• Cutters • PliersMounting LocationFeatures• T he device responds to temperature changes and care should be taken when mounting the device.• D O NOT mount directly above a heat source, in a location where hot or cold drafts will blow directly on the sensor, or where unintended motion (e.g., hallway traffic) will be within sensor's field-of-view.OR3. Test and mount.• R estore power. Wait 10-20 seconds for sensor to power up.• D OS05: lights will automatically turn ON with first motion seen after warm up period, or press push pad. • D VS05: press push pad. Lights should turn ON.NOTE: If lights do not turn ON, refer to the "What to do if..." section.Turn off power at circuit breaker before completing the installation. • G ently push wires into wall box. Screw light control to box. • I nstall wallplate.• Restore power.Single Pole3-Way (Neutral present)Wallbox2a. Wire (when Neutral is NOT present).W orking on one connection at a time, connect wires as shown.NOTE: This device is designed so the line and load wires can be wired interchangeably.Single Pole2b. Wire (when Neutral is present).R emove the GREEN sleeve from the white wire. Working on one connection at a time, connect wires as shown. N OTE: This device is designed so the line and load wires can be wired interchangeably.NOTE: Neutral wire (if present), or a Ground wire is required for operation. If the wiring in the wall box does not resemble this configuration, consult an electrician.NOTE: Sensor must be installed in the location where the load wire is.• Reorient or relocate the receiving Antenna. • Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/tv technician for help.FCC CAUTION: Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user's authority to operate the equipment.FOR CANADA ONLYFor warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1-800-405-5320.LIMITED 5 YEAR WARRANTY For Leviton’s limited product warranty, go to . For a printed copy of the warranty,call 1-800-824-3005.Patents covering this product, if any, can be found on /patents.Leviton and Block and Design logo is a registered trademark and Decora is a trademark of Leviton Mfg. Co., Inc.For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) PK-A3346-10-00-2A-X4© 2020 Leviton Mfg. Co., Inc.ARTWORK PRINT SPECIFICATIONSArtwork Print Specification Sheet Rev A13.eps。
mA corresponds to no switch-Solid State RelaysType SelectionSwitching mode Rated operational Rated operational Control current Non-rep. voltage voltage current E: Analog switching24: 115 VACrms10: 10 AACrms AA: 4 to 20 mA06: 650 V p 230 VACrms 25: 25 AACrms 12: 1200 V p 48: 400 VACrms50: 50 AACrms16: 1600 V p480 VACrms 60: 600 VACrmsSelection GuideRated operational Non-rep. voltage Control currentRated operational current voltage 10 AACrms 25 AACrms 50 AACrms Industrial, 1-Phase Analog SwitchingTypes RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16InsulationInput SpecificationsFunctional DiagramControl inputLoad output/mains inputMains input/load outputControl inputLine/loadWiring Diagram Output SpecificationsICRE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16Heatsink Dimensions (load current versus ambient temperature)With the output fully on (360°conduction angle)RE ..10 AA ..2.7 2.2 1.8 1.30.870.41223.1 2.6 2.1 1.7 1.20.65203.73,1 2.62 1.50.92184.3 3.7 3.1 2.5 1.9 1.2165 4.3 3.73 2.3 1.6155.9 5.1 4.4 3.6 2.8 2.1136.96 5.2 4.3 3.5 2.6127.9 6.9 5.9 4.9431010.89.58.1 6.8 5.4 4.17-14.212.210.28.1 6.15----14.610.93------12030405060701615141312111097531Loadcurrent [A]Thermal resistance [K/W]T AAmbient temp. [°C]Powerdissipation [W]RE ..50 AA ..T AAmbient temp. [°C]0.920.760.600.450.29- 631.20.990.800.620.440.26551.5 1.3 1.10.850.630.42471.9 1.6 1.4 1.10.890.63402.4 2.1 1.8 1.5 1.20.91333 2.7 2.3 1.9 1.5 1.1263.9 3.53 2.52 1.5205.5 4.8 4.1 3.4 2.7 2.1158.67.5 6.4 5.4 4.3 3.2917.915.613.411.28,9 6.742030405060705045403530252015105Powerdissipation [W]Thermal resistance [K/W]Loadcurrent [A]RE ..25 AA ..Powerdissipation [W]2 1.7 1.410.710.40 322.5 2.1 1.8 1.410.66273.1 2.7 2.3 1.9 1.41234 3.53 2.52 1.4204.9 4.3 3.7 3.1 2.5 1.9166.2 5.4 4.6 3.9 3.1 2.3138.17.1 6.1 5.1431011.39.98.57.1 5.6 4.27-15.613.311.18.9 6.75----18.71422030405060702522.52017.51512.5107.552.5T AAmbient temp. [°C]Loadcurrent [A]Thermal resistance [K/W]Carlo Gavazzi Heatsink (see Accessories)No heatsink required RHS 100 Assy RHS 301 Assy RHS 301 F AssyConsult your distributorHeatsink SelectionThermal resistance R th s-a > 12.5K/W3.0 K/W 0.8 K/W 0.25 K/W < 0.25 K/WCompare the value found in the current versus temperaturechart with the standard heatsink values and select the heat-sink with the next lower value.RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16ApplicationsThis relay is suitable for tem-perature control or control of lighting.The relay can also be used for soft turn-on of high-power in-candescent lamps.Load4 to 20 mALCFI inU lineRE 24.. AA 06U L = 230 V RE 48.. AA 12U L = 480 V RE 6050 AA 16 U L = 600 VApplication hints:L and C must be connected as close as possible to the SSR.Max. unit variation: ± 5% @ Tj = 25°CTemperature variation: ±5% @ Tj = -20°to + 125°CI in [mA]P out [%]typically 50/60 Hz40.5688221040125414661675188120862592Transfer characteristicsOutput power as a function of control input (4 to 20 mA)Dimensions************************ = ±0.4 mm ***= ±0.5 mmHousing SpecificationsAccessoriesProtection cover HeatsinksDIN rail adapter Varistors Fuses L: Optional radio interfer-ence low-pass filter com-ponentC: Optional radio interfer-ence low-pass filter com-ponentFor further information refer to "General Accessories".。
Palo Alto Networks | PA-5200 Series | Datasheet1Key Security Features: Classifies all applications, on all ports, all the time • Identifies the application, regardless of port, encryption (SSL or SSH), or evasive technique employed • Uses the application, not the port, as the basis for all of your safe enablement policy decisions: allow, deny, s chedule, inspect and apply traffic-shaping • Categorizes unidentified applications for policy control, threat forensics or App-ID™ application identification technology development Enforces security policies for any user, at any location • Deploys consistent policies to local and remote users running on the Windows ®; Apple ® Mac ® OS X ®, macOS™ and iOS; Linux ®; and Android™ platforms • Enables agentless integration with Microsoft ®A ctive D irectory ® and T erminal Services, LDAP, Novell ® e Directory™ and Citrix ®• Easily integrates your firewall policies with 802.1X w ireless, proxies, NAC solutions, and any other source of user identity information Prevents known and unknown threats • Blocks a range of known threats, including exploits, m alware and spyware, across all ports, regardless ofc ommon threat-evasion tactics employed • Limits the unauthorized transfer of files and sensitive data, and safely enables non-work-related web surfing • Identifies unknown malware, analyzes it based on hundreds of malicious behaviors, and then automatically creates and delivers protection The controlling element of the PA-5200 Series is P AN-OS, security operating system, which that natively classifies all traffic, inclusive of applications, threats and content, and then ties that traffic to the user, regardless of location or device type. The application, content and user – in other words, the elements that run your business – are then used as the basis of your security policies, resulting in an improved security posture and a reduction in incidentresponse time. Palo Alto Networks ® PA-5200 Series of next-generation f irewall a ppliances is c omprised of the PA-5260, the PA-5250 and the P A-5220, which target high-speed data c enter, internet g ateway, and service provider deployments. The P A-5200 Series delivers up to 72 Gbps of throughput using dedicated p rocessing and memory for the key functional areas of n etworking, security,threat prevention and management.PA-5200SERIES 1 Performance and capacities are measured under ideal testing conditions. 2 Firewall throughput measured with App-ID and User-ID features enabled utilizing 64K HTTP transactions 3 Threat prevention throughput measured with App-ID, User-ID, IPS, A ntiVirusand Anti-Spyware features enabled utilizing 64K HTTP transactions 4. New sessions per second is measured with 4K HTTP transactions 5. Adding virtual systems base quantity requires a separately purchased license PA-5260PA-5220PA-52504401 Great America Parkway Santa Clara, CA 95054 Main: +1.408.753.4000 Sales: +1.866.320.4788 Support: +1.866.898.9087 © 2017 Palo Alto Networks, Inc. Palo Alto Networks is a registered trademark of Palo Alto Networks. A list of our trademarks can be found at / company/trademarks.html. All other marks mentioned herein may be trademarks of theirrespective companies. pa-5200-series-ds-020817Networking FeaturesHardware Specifications。
1.Lift the AM5200 (-A) from the box using thehandles built into the protective foam.2.Set the instrument down on a sturdy surface andremove foam packaging and plastic cover. Place all packaging back in the box and store for future use.Original packaging is required for shipping. Also remove the display cover, funnel cover, and any tape.3.Check the box for operation manual and power cord.4.Pull out the blue catch drawer and set aside.Thedrawer will need to be replaced to run samples.5.Disengage transport locks. The unit cannot performmeasurements while the locks are engaged. It isimportant that the locks be re-engaged before shipping.A full instruction can be found on page 2.6.Remove the top lid by simply pulling it up. Do not pullfunnel wire guards. Level the instrument by adjustingthe rubber feet, using the level mounted on the toppanel and to the left of the funnel assembly. Snap lidback in place.7.Plug in and turn on the instrument.8.Configure any settings such as time, date, units, andoutput mode or begin analysis. A quick guide toanalysis can be found on page 3.8a. To configure settings, press Menu→General Settings →Change Access Right. Select the top white field andenter 142857 on the keyboard screen followed by“enter” to log in as an Administrator. Settings can nowbe changed. These are found inMenu→General Settings→Local Settings and Menu→General Settings→Analysis Options.8b. Specifics concerning individual settings are described in detail in the operation manual.HandlesUnlocking the Transport LocksThe Transport Locks are located near sharp edges. Wear gloves and use caution whenremoving and setting Transport Locks.1. Transport Lock 1 is secured by a magnetic catch. To unlock, tilt the plate to release thelocking pin and slide the red plate to the lower position. Ensure the locking pin enters the top hole for unlocked position.The two figures below show Transport lock 1 in Locked and Unlocked positions.2. Transport Lock 2 is secured by three thumbscrews. Remove thumbscrews A and B and loosenthumbscrew C. Slide lock bracket to the Unlock position as displayed in the graphic below. Reinstall thumbscrew A in its original position and B in the unlocked position. Ensure all thumbscrews are snug.The two images below show clamp 2 in Locked and Unlocked positions.Before moving or shipping the AM 5200 (-A), please ensure both Transport Locks are properly secured . To lock, simply reverse the unlocking procedure.ABCACBTransport lock 1 in Locked position.Transport lock 1 in Unlocked position.Analyzing SamplesSelect product by pressing the corresponding button.2To analyze the nextList of Additional/Replacement Parts*Contact us for the latest pricing and availability - 217 - 585 - 9440。
一、概述本控制器用于控制电动转换开关、接触器、电动操作空气开关,实现双电源自动切换。
该控制器采用微机技术,AD数据采集,可同时监测两路三相电源的过压、欠压、断相。
液晶显示器可实时显示测量电压值及各种状态信息。
该控制器对所有系统参数及可选控制功能均可通过中文液晶设置菜单进行现场设置及更改, 485通讯接口,可实现三遥功能。
为满足现场要求控制器可实现自动返回、故障返回、复位返回三种切换方式,也可选择电源I或电源II为首选电源及市电-市电、市电-油机切换。
二、电气性能及功能1工作电源:交流型:AC230V(±20%),50HZ2 环境温度: -10°C~70°C3 电源Ⅰ/电源Ⅱ电压检测•单相或三相 AC230V/380V•±1%精度4 可任意选电源I或电源II为首选电源5.可选择自动返回(自投自复)、故障返回(互为备用)、复位返回(自投不自复)6.可选择控制器为市电/市电或市电/油机工作模式7 火灾报警信号联动---转换到零位(DC24V输入)8.过流跳闸自动报警9.转换开关位置信号采集(有源AC110-280V)10.可编程输出: 负载在电源Ⅰ负载在电源Ⅱ电源Ⅰ正常电源Ⅱ正常双电源正常启动油机( 230V 5A )11 转换控制输出•转换位置Ⅰ输出 ( 常开230V 5A )•切换位置Ⅱ输出 ( 常开230V 5A )•切换位置0输出 ( 常开230V 5A )12.RS232/485通讯接口•可遥控、遥测、遥信13.转换延迟--由位置I转到位置II的延迟0-255秒14.返回延迟--由位置II转到位置I的延迟0-255秒15.冷机延迟--在市电/油机模式开关返回到位置I后停止油机运行延迟0-255秒16.转换到中间位延迟0-11秒注:若将可编程输出设置成(启动油机)则控制器为市电/油机工作模式三、操作及显示液晶屏自动循环显示如下内容第一行第二行第一行显示内容•电源I正常•电源II正常•电源I故障•电源II故障•自动工作方式•手动---位置I•手动---位置II•手动---位置O•遥控---位置I•遥控---位置II•位置II >位置I•位置I >位置II•跳闸或接线故障--------开关过流跳闸或位置返馈线联接错误•火警联动-----------------接收到火警联动信号•转换延迟XXX秒-----主电源转换到备用电源的延迟•返回延迟XXX秒-----备电源转换到主电源的延迟•冷机延迟XXX秒-----油机/市电工作模式,转换开关返回到市电取消启动油机信号注. 当电源I或电源II失电时转换到位置O功能无效第二行显示内容•第一路相电压/线电压 PI XXXV XXXV XXXV•第二路相电压/线电压 PII XXXV XXXV XXXV•电源I断相•电源II断相四、控制器遥测-遥信-遥控功能通过计算机通讯接口可进行远端遥控及电量采集。
瑞数主动防御解决方案25瑞数ALL IN ONE动态安全超融合解决方案瑞数信息 ( River Security ) 成立于2012年,是国内创新推出动态安全技术,全程动态保护企业网站应用、业务交易及数据安全的主动式防御厂商。
公司总部位于上海,在北京、广州和深圳分别设有分支机构,并在成都设立研发中心。
瑞数信息创新的“动态安全”技术,完全颠覆了当前依赖攻击特征和策略规则的被动式防御技术,可对已知和未知的自动化攻击,及各种利用自动化工具发起的恶意行为做到及时、高效拦截,防护范围覆盖业务反欺诈、Web安全、APP安全、API安全、业务威胁感知、数据透视与分析以及物联网等众多领域。
结合“动态安全”与“AI人工智能”两大核心技术的协同效力,不仅在既有的动态验证、封装、混淆、令牌四大动态安全技术上加入全新的“动态挑战”技术,更融入了机器学习、智能人机识别、智能威胁检测、全息设备指纹等AI技术。
让安全能力从主动防御,提升到可持续安全对抗的新台阶,高效防护各类数字化时代的新兴威胁。
作为中国动态安全技术的创新者和Bots自动化攻击防护领域的专业厂商,瑞数信息自2012年成立以来迅速成长,产品已实现销售额超过亿元,覆盖三大运营商、银行、证券保险、政府、制造、交通、能源、电商互联网等行业客户。
面对未来安全形势中的各种未知和挑战,瑞数信息有信心,更有实力让企业领先威胁一步,让安全领先攻击一步!关于瑞数信息我们的优势简单应用端不需要改动任何源码, 后期运维工作量明显降低需改应用服务器配置,大量维护安全克服传统技术天然缺陷,阻拦“已知”和“未知”自动化攻击依靠已知,亡羊补牢高回报释放系统资源、降低运维成本回报难以体现传统传统传统• 主动防御 - 不依赖特征码、阈值、补丁和策略规则。
通过动态技术令漏洞扫描、漏洞利用工具完全失效。
• 轻量管理 - 无需修改任何应用服务端代码或业务逻辑,无需部署客户端。
• 态势感知 - 独特和细粒度的自动化攻击行为透视,准确定位攻击。
WDZ-5200系列保护测控装置调试指导版本:试用版编制:朱曙光黄庆建审核:批准:日期:金智科技股份有限公司2010-4-9调试操作流程一、检查接线,装置上电:1、先确保装置供电直流空开在分开位置。
.2、确保万用表的线头插在在公共和电压端,选用直流1000V档,测量装置供电端子之间以及端子和地之间是否存在电压。
并且测量空开电压是否负荷装置供电电压。
(DC110V或DC220V,根据装置选型而定)3、确保无电压后,万用表选用欧姆通档,测量装置电源端子之间及电源端子和地之间是否存在短路。
4、确保无短路情况后,装置可以安全上电。
二、软件版本和工程配置检查:1、软件版本检查:2、工程配置检查:说明:工程配置在出厂调试时已按照工程进行修改,在现场调试时只需进行检查是否符合现场需要,若不符合,则按照下面步骤修改:a、恢复出厂设置:(现场无需修改)主菜单→定值设置→恢复出厂设置,输入密码:2006。
b、工程配置主菜单→调试操作(输入密码2006)→厂家设置,对照工程配置表,对以下几项进行配置:1)I/O配置:配置操作板或I/O板型号。
2)工程选配:CT:5A、1A;现场总线:CAN、PROFIBUS、RS485、以太网;4-20mA输出:一路、二路;PT接入方式:线电压(默认选择)、相电压;CT接入方式:三相、二相;开关位置接入:双位置接入(默认选择)、跳位接入、合位接入。
c、系统设置主菜单→定值设置,对以下几项进行配置(输入密码0001):1)CAN/RS485:设置为接口检查;(用于方便出厂调试)2)4--20mA输出关联测值:设置为MIa。
d、设置装置时间主菜单→时间设置,修改正常时间即可。
e、检查运行灯:查看运行灯是否为灯常亮,其它灯不亮。
三、精度验证、电能验证、4-20mA调试、脉冲调试(以WDZ-5242带操作板装置为例)1、装置采样:分为两个步骤a、第一步判断电压、电流相序是否接反:Ua、Ub、Uc三相电压各相施加20V、30V、40V,高、低压侧电流IA、IB、IC各相电流施加1A、2A、3A,查看装置对应相测量电压、电流以及保护电压、电流是否跟施加的相同。
Operator’s manualLong-seam Machine 5200 seriesVersion D. July 2009We reserve the right to make changes in this documentContents:CHAPTER 1: EU DECLARATION OF CONFORMITY.....................................................- 3 -CHAPTER 2: GENERAL...................................................................................................- 4 -CHAPTER 3: SAFETY ADVICE AND NOTICES..............................................................- 5 -CHAPTER 4: HOW THE MACHINE WORKS:..................................................................- 7 -Sketch of the automatic machine:.............................................................................................................- 7 -Starting and stopping the machine:...........................................................................................................- 8 -Failure during start-up, operation or shut-down:.......................................................................................- 9 -Maintenance:...........................................................................................................................................- 10 -Basic precautions....................................................................................................................................- 11 -Maintenance checklist:............................................................................................................................- 13 -Storage of this operator’s guide:.............................................................................................................- 14 -CHAPTER 5: ASSEMBLY AND DISASSEMBLY...........................................................- 15 -Design and construction of the automatic machine:...............................................................................- 15 -Connecting up:........................................................................................................................................- 16 -Disassembly:...........................................................................................................................................- 16 -CHAPTER 6: TECHNICAL SPECIFICATIONS...............................................................- 17 -External connections:..............................................................................................................................- 18 -List of replacement parts – long-seam automatic machine.....................................................................- 21 -Always read the operator’s manual carefully and thoroughly beforeoperating the machine. When working, always bear in mind the directionsand safety instructions provided in this manual. When installing and operating the machine, follow the safety directions stated in the chapter of this operator’s manual entitled SAFETY ADVICE AND NOTICES. This operator’s manual must always beavailable to the persons installing, operating and servicing the machine.Chapter 1: EU Declaration of ConformityManufacturerCompany name: Migatronic Automation A/SAddress: Knøsgaardvej 112DK-9440 Aabybro, DenmarkTelephone: (+45) 96 96 27 00Internet: www.migatronic-automation.dkhereby declares thatThe machineMake: Long seam automatic machineType: 5200has been manufactured in compliance with the provisions of the COUNCILDIRECTIVE of 14 June 1989 on mutual approximation of the laws of themember states on machines (89/392/EEC as amended by 91/368/EEC and93/44/EEC) with special reference to annexe 1 of the Directive on essentialhealth and safety requirements in connection with the design and manufactureof machines (cf. Statutory Order of the Danish Working Environment Authority(Arbejdstilsynet) No. 561 of 24 June 1994).25/8-2006 Keld KjeldgaardDate SignatureChapter 2: GeneralThe MIGA-5200 long-seam automatic machine is designed for the welding ofpipes, vessels and sheets from various materials.MIG/MAG, TIG and plasmawelding are all processes which can be applied to this machine.The automatic machine comes supplied as standard fitted with a type 4005control system, torch cradle, cross-support for the manual adjustment of torch,pneumatic centring device, foot switch and mandrel lock.The control system handles functions such as:* Speed regulation* Pre-welding time* Post-welding time* Manual/automatic return/seek of start sensor* Manual operation* Switch with/without arc control* Welding direction* Post-welding/crater filling* Switch with/without weldingIf power sources are used in connection with the machine, read the operatingmanual of the power source prior to starting work.Chapter 3: Safety advice and noticesPERSONAL SAFETYLight and heat emissionA welding arc emits radiation which is damaging to the human eye. Even short-term exposure to this radiation can cause permanent damage. Your eyes must be protected against powerful infraredradiation, as well as visible and ultraviolet light by using suitableradiation protection glass fitted in your welding helmet. Your skin may also be damaged by this radiation. Radiation can cause serious burns. Protect your skin by wearing the helmet, full-body working overalls and gloves. Warn other people in the vicinity of the welding area of the danger of radiation and flying sparks. If possible, screen the workplace off from the surrounding environment. Together with flying sparks, heat radiation from the electric arc and the molten pool constitute a fire risk. For this reason, do not perform welding in the vicinity of flammable materials. Do not put the torch down without first extinguishing the flame. Your working clothes must not contain easily flammable materials or have creases or open pockets which may collect sparks. Wear a fireproof apron if appropriate. After completion of the work, switch off at all socket outlets or at the main valve, and depressurize hose couplings.Welding fumesThe smoke and fumes generated by the welding process are hazardous to health. Therefore extraction systems must be installed in such a way that the fumes which arise during welding are removedeffectively. When fumes from degreasing agents are acted on byultraviolet radiation from the electric arc, this may produce very toxic phosgene gas. For this reason, all dissolvents, degreasing agents and other potential sources of such fumes must be kept away from the welding area. Avoid inhaling welding fumes and gases. Use benches with extraction or other extraction systems for removal of welding fumes and gases. Use oxygen masks if no such effective extraction system is possible.ElectricityAvoid making contact with live components.The voltages used in connection with welding are not high enough topose a risk of serious electric shock. However, minor electric shocks may result from damp overalls and the like, and these can frighten thewelder, so potentially posing an indirect safety hazard. In particular, HF high-voltage ignition in TIG and PLASMA welding can generate powerful shocks and cause minor burns under the skin. Contact with live welding parts should therefore be avoided as far as possible. Always ensure that cable insulation, as well as insulation on the torch and machine pin and socket connectors, is fully intact. Always wear dry leather gloves, dry overalls and dry footwear. Furthermore, keep cables, torches and the welding machine itself dry at all times. It is important that the machine’s connections have been set up according to the applicable regulations (power cables, fuses and safety conductor/earth lead). Do not open the machine to expose the live parts. Service and maintenance requiring access to live parts of the machine must only be undertaken by properly qualified personnel. Never leave a dismantledmachine connected to the mains supply.Applications:- TIG welding hoses (live cables) and torches must not be placed on the electronic control box.- Do not exceed the maximum dimensions for work pieces laid down in the operator’s manual.- The machine/equipment may only be run by operators who have been trained in its use and who have also worked through the operator’s manual.Removal of safety devices:- Safety devices may not be disabled or removed during operation.Correct placement of work pieces:- Prior to starting work with the machine, the operator must ensure that the work piece has been correctly placed and properly secured.Chapter 4: How the machine works:Sketch of the automatic machine:Welding and clamp length M in. diam.Max. diam.below mandrel A rticle numbermiga-5205A 600 90 800 79115205-1 excl. quick fingeradjustment. miga-5210A 1100 140 800 79115210-1 excl. quick finger adjustment. miga-5215A 1600 160 800 79115215-1 excl. quick finger adjustment. miga-5220A 2100 180 800 79115220-1 excl. quick finger adjustment. miga-5225B 2600 260 800 79115225-1 incl. quick finger adjustment.Starting and stopping the machine:Set mandrel height (A) and set finger clamps to the correct distance apart. Activate the main switch on the reverse (B) of type 4005 control systems.Place the work piece in the long-seam fixture. Secure the mandrel to top clamping bar (C) by means of the mandrel locking device (D). Secure the work piece by means of marker system (E) which is activated using a flap valve (F) and secure into place by activating the foot switches (G) one side at a time. Use the cross-supports (H) to set the welding gun to the correct position. On how to set the welding speed, pre-welding time, post-welding time etc., refer to the operator’s manual for the 4005 control system.Adjust the inductive sensors on the rails to the desired positions (see “Connecting up” in chapter 5).For welding with cold wire feed, set the wire speed on the type KT4 cold wire feeding unit. Refer to the separate operator’s guide for this. Set the switch (pos. 16) on type 4005 control systems for manual or automatic return. Activate the start button (pos. 13) on type 4005 control systems and perform the welding using the programmed data.When you have completed the welding, loosen the finger clamp via the pneumatic foot switches, release the mandrel locking device and remove the work piece.In the case of automatic machines on which quick-finger-adjustment is fitted as additional equipment, adjust the finger distance by turning the bolts (I). These bolts are connected by a rod, which transports the fingers on each respective side of the copper rail. Adjust until the distance between the fingers is correct and the distance to the centre line of the copper rail is equal for both finger rows.Failure during start-up, operation or shut-down:If monitoring of the electric arc (arc control) and welding have been activated, the automatic machine will not start until the electric arc has been established.While the machine is in this waiting mode, the operator must be aware that it may start once the electric arc is started.Maintenance:Regular maintenance is important.This ensures:* A long service life for the machine* Safety* Operational reliabilityMany of the maintenance tasks are simple for the operator to perform himself using just a few tools.These tasks are described below.However, note that some maintenance tasks require special tools and expertise. Such tasks should be given to qualified Migatronic employees. Even if you are an experienced DIY-mechanic, we recommend that you hand over repairs and maintenance to Migatronic Automation A/S (+45 96 96 27 00).Basic precautionsWarningcomponents.- Make sure you keep the work area clean and tidy.- Disconnect the power and air supply to the machine when it is not in use or isleft unattended.DAILY CHECKS BEFORE START-UPInspect the control system:A. Check that all power and fuse lamps light up.B. Ensure that the plug is properly inserted in the rear.C. Perform a cycle without doing any welding.Check mains leads, earth cables, air and gas hosesA. Check for external damage.B. Check for loose connections, elements or leaks.Welding control:Weld a work piece and compare to the one you retained from the same time theday before.If everything is OK, retain the piece you just welded for start-up on the followingday.WEEKLY CHECK-UPClean all important surfaces using compressed air and lubricate sparingly withmachine oil.Sign the maintenance checklist.MONTHLY CHECK-UPIn addition to the weekly inspection, check all nuts and Unbrako screws – especially on ball bearings, gun mounting and roll guides.Release carbon in the carbon holder (if any is fitted) and clean with compressed air, checking the carbon length. Check gear motors for leakage in gear gaskets and check wires. Check for play in main bearings. Clean the power sources internally (remember to remove the mains lead!). Sign the maintenance checklist.Maintenance checklist:Date Weekly check-up Monthly check-up Comments Init.Storage of this operator’s guide:Keep this operator’s manual in a place accessible at all times to operators, maintenance personnel and repairmen.Chapter 5: Assembly and disassemblyDesign and construction of the automatic machine:The machine is supplied with a solid machine bed (E) on which the robust and stable top clamping bars (B), as well as the equally solid vertically and laterally adjustable under-mandrel (D), are mounted. The under-mandrel is locked to the top clamping bar with mandrel lock (C), which is fitted on the end of the projecting part of the top clamping bar.A row of wide finger clamps with replaceable copper shoes are fitted on the underside of the top clamping bars. The finger clamps are designed so that when they are tensioned, they move down towards the plate edge and then in towards the centre line of the automatic machine. Each row is activated separately via the foot switches (K).The machine is fitted with rails (A) upon which carriage (F) runs. The gear motor can be disengaged via a disengagement grip (G), after which, the carriage can move manually and easily back and forth on the rails. All operating buttons are fitted on the front panel of the control system (H). A gun slide (I) is fitted on the carriage, on which a gun mounting is supported with cross-supports (J).A replaceable copper backing bar is fitted on the topside of the robust under-mandrel. For replacement, a plate by the mandrel lock is loosened, the bar removed and a new oneinserted. The copper backing bars come in several types depending on the welding method and thickness of the work pieces.DEJConnecting up:Compressed air is connected via a filter reduction value fitted on the end of the long-seam fixture. The welding gun is mounted in the gun support.To move/adjust the inductive sensors, turn the hand-clips a quarter turn. This allows you to then flip the shielding down.WarningDisconnect all mains power before flipping the shielding down.Working sensor – left Working sensor – rightEnd stop sensor – leftEnd stop sensor – rightThe illustration above shows the rails without shielding. After final adjustment, flip the shielding into place again.WarningDo not leave the long-seam automatic machine in a dismantled condition.Disassembly:The old machine contains reusable parts.For this reason, do not send your automatic machine to the nearest tip; instead, contact your local council or an auto or scrap dealer about the possibility of reusing parts.Disconnect all external connections (electrical, air etc.) before disassembly.Chapter 6: Technical specifications Technical data:Machine weight – see table belowControl system weight: 12 kgNoise level: < 70 dB(A)Type Heightapprox.mm Widthapprox.mmLengthapprox.mmWeight Article numbermiga-5205A miga-5210A miga-5215A miga-5220A miga-5225B miga-5230B 15001500150015001500150085085085085085085015402040254030403540404079115205-179115210-179115215-179115220-179115225-179112530-1181920Please note that some part in this diagramme are mounted as options, and are not standard.List of replacement parts – long-seam automatic machine Pos. nr. Description Article number1 Unbrako screw M8x80 40310880-12 Toothed belt pulley 19H100 47419422-13 Seeger-A-ring DIN471-20x1.2 42510020-14 Shaft for toothed belt pulley. 25403005-15 Ball bearing 6204-2RS1 44166204-16 End stop sensor – left 17100809-17 Working sensor – left 17100809-18 Movement rail SBG25 000015269 Tandrem:Type 1100 : 1250H100 Type 1650 : 1700H100 Type 2000 : 2000H100 Type 2500 : 2400H100 Type 3000 : 2800H100 Type 3500 : 3150H100 Type 4000 : 3550H100 Type 4500 : 3950H100 47041250-1 47041700-1 47042000-1 47042400-1 47042800-1 47043150-1 47043550-1 47043950-110 Kørevogn 1651-214-10 25mm 45032040-111 Tastebeslag for føler 27111002-112 Kontaktarm 45080032-113 Arbejdsføler, højre 17100809-114 Endestopføler, højre 17100809-115 The engine and gearbox, depending on speedMotor 0.25 kW / 1,350 rpm Gear i = 240Motor 0.12 kW / 660 rpm Gear i = 300 (TIG / Plasma) Gear i = 114 (MIG / MAG) 17290070-1 17290071-1 17290073-1 17290072-1 17290074-116 Taper lock bushing 1210-15 46341526-1。
ASD5300产品使用说明书V1.0目 录一、注意事项: (2)二、技术特点及使用范围: (2)三、执行标准: (2)四、主要技术参数: (3)五、探测器结构: (4)1、ASD5300外形结构(图1): (4)2、ASD5300外形尺寸(图2): (5)3、ASDIR-01A红外遥控器(图3): (5)六、探测器的安装: (6)七、设置使用说明: (9)1、显示面板结构(图7): (9)2、设置操作说明: (9)3、故障分析及处理: (11)八、日常使用维护: (12)九、售后服务: (12)十、产品装箱单: (12)一、注意事项:欢迎选用安仕得科技有限公司的ASD5300系列产品。
在安装、调试和使用本产品前,请仔细阅读和理解使用说明书。
1、探测器的安装及调试应由专业的技术人员进行。
2、探测器的壳体接地端子应可靠连接大地,接地阻抗应≤4Ω。
3、当探测器超过其使用寿命,请及时更换传感器并从新校准探测器。
4、应定期检查和清理探测器的进气口,避免被灰尘异物阻塞进气口导致探测器失准。
5、严禁在可燃气体等危险环境下打开探测器外壳。
严禁使用纯净气或高浓度气体对探测器进行测试,如进行该操作将导致探测器传感器产生积碳从而失准,大大降低了传感器的使用寿命甚至损坏传感器。
二、技术特点及使用范围:ASD5300X点型可燃气体探测器是我公司开发的智能采样高端多功能的气体探测器。
产品的主要技术特点如下:1、探测器外壳采用加厚防爆铝合金外壳,加厚防爆玻璃面板,保证产品可以在各种工业防爆环境中长期稳定的工作。
2、总线式探测器电源及总线部分均采用无极性方式设计,总线采用抗干扰防静电保护电路,保证探测器长期稳定工作。
3、采用高亮彩色LED图形显示屏实时气体浓度显示,在保证远距离观察气体浓度的情况下又保证了产品的环保节能。
4、探测器使用专用的红外遥控器操作,软件采用多线程嵌入式系统驱动智能人机对话界面进行编程,客户可以通过简便的操作即可对探测器的相关功能(详见操作说明书部分)进行调节满足客户各种功能需求。
一、概述HD5200系列智能型电机保护控制器采用单片机微处理器芯片和现代微电子控制技术开发设计。
测量精度高,故障判断准确可靠,是新一代电动机保护控制产品,广泛用于电动机运行保护控制领域。
本公司生产的智能电动机保护控制器,属系列产品中应用极广的智能产品,适于各种大、中、小型电机的电流、电压等综合保护控制。
二、功能特点●采用单片机数字处理技术,采样速度快,测量精度高,故障分辨准确,保护控制可靠,抗干扰能力强。
●通过采样5A(1A)电流、电压,得到电测量的基本参量;保护功能可通过设定,有选择地关闭,可作为电流、电压监控仪表使用。
●功能齐全,使用灵活,方法简单,几十种保护参数可由用户通过密码根据电机实际情况自行设定。
●参数设定按键操作,掉电后永久保存,不需重新设定。
●四组、四位LED数码显示,在运行状态下可循环显示电压、电流(或切换显示电流、电压);在设定状态下用于显示设定参数。
●八个故障指示灯,提示故障原因,便于排除故障。
●具有短路、启动超时、定时限过负荷、堵转、缺相、三相电流不平衡、反时限过负荷、接地、漏电、过压、欠压、晃电再启动等各种故障保护控制功能。
●具有四组开关输出接口,用于启动/停止电机、报警、切断故障电动机电源。
●具有远程复位开关量输入接口和面板按键复位功能。
●允许多种启动方式,如直接启动、降压启动、软启动、星/角启动、可逆运行、双速运行等。
●具有11个开关量输入接口,用于对电机进行控制。
●具有电流变送输出功能,信号种类可选。
●具有RS485通讯功能,便于实现DCS系统控制。
不仅可以启动/停止电机,还可以上传故障原因、故障时间和电流电压。
●面板具有电机启动停止按钮。
可替代现场按钮或与现场按钮并用,技术人员现场操作非常方便。
●保护控制器电源DC、AC220V。
●盘装仪表标准尺寸160*80*170mm。
三、主要技术指标●测量范围:0.001A-9999A AC●测量精度:0.5级●输入电流:0-5A AC(电流互感器二次标称值)●输入电压:AC400V●控制触点容量:AC 400V/5A●触点特性:保护触点均为双触点。
ASD5200电源控制器 产品使用说明书V1.0
注意
在安装、调试和使用本产品前务必仔细阅读和理解该使用说明书!
一、产品概述
ASD5200电源控制器主要用于安仕得生产的需要低压电源持续供电的探测器及模块等使用。
具备主备电自动切换等功能。
可实现控制器集中远距离监控现场电源情况的功能。
二、安装
注意:本产品为非防爆设计,不能安装在防爆区域,如果需要安装在防爆区域,可增加防爆外壳。
安装方法:
先使用膨胀螺钉或其它安装方式将挂板固定于安装墙面之上,然后检查安装是否稳固,最后将电源控制器对准扣片挂装于挂板之上。
电源控制器的下方及上方分别有2个穿管孔,可将外部的管材通过孔进入联动控制箱内部。
穿管时,将橡胶护套戳破,然后将管材穿入。
管材的两头应当用专用工具套丝。
进入联动控制箱后,用丝扣将管材的上下全部拧紧,管材的出线口应当套护口。
建议用户在选用管材时尽量选用口径为Ф15、Ф20 的镀锌管(标管)。
管材口径的大小选用:一般根据管子内要布的线的多少而定。
三、接线
1)与控制器的通信连接
联动控制器正常工作需要与控制器之间建立正常的通信,我公司的电源控制箱是直接接在ASDBUS 总线上的,连接线路如下图所示:
总线连接:总线采用四总线ASDBUS 通讯方式,只需要区分电源线和信号线,而电源线和信号线之间不区分正负极。
四、功能操作
电源控制器设置都必须在通电后(数码管有显示)进行。
注意:电源控制器占用1个电源控制器地址,而不占用探测器的地址。
1 )设置地址:用于为联动控制器设置地址编号
注意:设置地址必须是在联动控制箱通电之后才能进行,否则无法进行设置。
第一步:将联动控制器通电,当联动控制箱数码管点亮之后开始倒计时,倒计时后便可开始地址设置。
第二步:同时按住2个按键持续2秒抬起后可以进入地址设置界面,上面显示A001为当前地址,如需设置长按右侧按键2秒后抬起,这时地址显示数字开始闪烁。
第三步:按一下左侧按键当前地址将+1,每按一次地址将自动+1。
地址最大调整到31后自动回1。
第四步:按长按右侧按键,可以保存修改后的联动箱地址。
第五步:修改好之后,将显示SUCC,保存成功。
第六步:地址修改完毕,返回待机界面显示当前时间。
第七步:搜索电源控制器(通过配套的控制器进行此项操作,在控制器节点登记中进行搜索)。
登记后的电源控制器如果发生故障,配套控制器将报出相应故障。
五、故障分析与排除
出现不能自行排除的故障时,联系厂家或代理商由专业人员处理,严禁非专业人员拆装!。