UF-100尿沉渣分析仪检查尿中红细胞形态及其临床意义作者:魏明甘文张秋英姚全良【关键词】 UF-100尿沉渣分析仪【摘要】目的探讨用UF-100尿沉渣分析仪判别血尿的性质及临床意义。
方法用Sysmex UF-100尿沉渣分析仪检测326例血尿病人的尿中红细胞形态与用相差显微镜镜检的方法比较。
结果 UF-100尿沉渣分析仪和相差显微镜的符合率为81.4%。
以相差显微镜镜检形态为标准,UF-100检测标本的假阳性率为11.9%,假阴性率为18.6%。
敏感度为81.4%,特异性为88.1%(以上数据为3种形态的平均值)。
用UF-100尿沉渣分析仪判别血尿的性质与相差显微镜镜检的方法差异无显著性。
结论用UF-100尿沉渣分析仪检测尿中红细胞形态正确率高,速度快。
关键词肾性红细胞非肾性红细胞 UF-100尿沉渣分析仪【Abstract】 Objective To study the nature of hematuria and their clinical significance by used the UF-100 uric sediment analysor. Methods To analyse the appearance of uric erythrocyte of325hematuric cases by used the sysmex UF-100uric sediment analysor and phase constrast microscopy,and compared the two methods. Results There was not significant different in estimation the nature of hematuric by used the UF-100uric sediment analysor and phase contrast microscopy. Conclusion Itis fast and the validity rate is high to analyse the appearance of the uric erythrocyte by used the UF-100uric sediment analysor.Key words dysmorphic(renal)-RBC isomorphic-RBC(non-renal)the UF-100 uric sediment analysor尿沉渣检验方法学主要是显微镜检查的标准化和沉渣中有形成份分析方法的改进[1]。
UF-100尿沉渣分析仪影响红细胞计数原因分析
邢智东;栾丽伟;邢智敏
【期刊名称】《中外医疗》
【年(卷),期】2009(28)20
【摘要】目的观察UF-100尿沉渣自动分析仪红细胞假阳性假阴性的干扰因素.方法使用UP-100全自动尿沉渣分析仪,实行组套尿沉渣检验,先用UF-100尿沉渣全自动分析仪和H-500十一项干化学尿分析仪进行过筛检验.如现2种方法尿红细胞检验.结果阳性结果不相符,则进一步做离心尿沉渣镜检或尿潜血.结论组套尿沉渣检验假阳性及假阴性的问题是可以排除的.
【总页数】1页(P160-160)
【作者】邢智东;栾丽伟;邢智敏
【作者单位】黑龙江省鸡西市妇幼保健院;黑龙江省鸡西市人民医院,黑龙江鸡西,158100;黑龙江省鸡西市人民医院,黑龙江鸡西,158100
【正文语种】中文
【中图分类】R69
【相关文献】
1.UF-100全自动尿沉渣分析仪对红细胞检测的影响因素分析 [J], 陈莹
2.UF-100尿沉渣分析仪对尿白细胞和红细胞检测的影响因素分析 [J], 聂文英;段聪明
3.UF-100尿沉渣分析仪尿液有形成分检测假阳性结果原因分析及其对策 [J], 石晶;赵敏;张家红;张丽霞
4.UF-100尿沉渣分析仪测定管型的影响因素分析 [J], 李杰
5.UF-100全自动尿沉渣分析仪对红细胞检测的影响因素分析 [J], 陈莹;
因版权原因,仅展示原文概要,查看原文内容请购买。
Uf-100全自动尿沉渣分析仪测定管型的影响因素摘要】目的本文分析uf-1oo全自动分析仪测定尿液中管型的影响因素。
方法随机收集800例标本,分别用uf-100分析仪和显微镜进行分析比较。
结果表明人工显微镜检查在临床检查中仍然占有非常重要的地位,仪器检查只是一种筛查手段。
【关键字】 uf-100全自动尿沉渣分析仪管型测定Uf-100全自动尿沉渣分析仪是对尿液做直接染色后,利用流式细胞技术和电阻抗技术根据尿中各类有形成分产生的前向散射光脉冲和荧光脉冲的强度、持续时间的长短以及电阻抗的大小来区分各成分的,但各检测项目和其相应的影响因素存在形态大小染色性方面的相似之处,因此该仪器还不能严格区分各类成分。
在实际应用中,发现该仪器对管型的测定有较高的假阳性率。
本文分析了uf-100尿液分析仪对管型的阳性计数结果和显微镜镜检结果对比。
1 资料与方法1.1一般资料本院门诊及住院患者的晨尿1.2仪器与试剂 UF-100 尿沉渣分析仪及配套试剂、质控物(日本Sysmex 株式会社);显微镜(Olympus)。
1.3方法随机收集800例门诊及住院患者的清洁中段尿,用uf-100分析仪进行检测;同时取10ml于刻度离心管,1500rpm离心5min,吸去上清液,管底留约0.2ml,混匀后取20ul滴在载玻片上,用18mm×18mm盖玻片覆盖并用显微镜观察全片。
[1]1.4判断标准对超过uf-100分析仪管型的报警限值(过筛值设置为0ul)为uf-100的阳性检测结果;显微镜观察全片看到一个以上的管型为阳性;uf-100分析仪检测阳性而显微镜观察为阴性的结果是uf-100的假阳性结果。
2 结果用uf-100分析仪检测800例门诊及住院患者的尿液标本,253例标本管型阳性,显微镜复检176例管型阳性,假阳性率为30.4%。
尿液中的粘液丝,精子,脓细胞团,酵母菌及细菌等影响uf-100分析仪对管型的检测。
3 讨论管型是一些有机物或无机物,如蛋白,细胞或结晶等成分在肾小管和集合管内形成的圆柱状结合物。
1.红细胞(RBC)红细胞出现在散射图的左角。
由于红细胞在尿液中直径大约是8.0um,没有细胞核和线粒体,所以荧光强度(Fl) 很弱,红细胞在尿液标本中大小不均,且部分溶解成小红细胞碎片,或者在肾脏疾患时排出的红细胞也大小不等,因此红细胞前向散射光强度(Fsc)差异较大。
一般来看,Fl几乎极低和Fsc大小不等都可为红细胞。
该仪器除给出尿红细胞数量(每微升的细胞数和每高倍视野的平均红细胞数)参数外,还可报告尿红细胞其他参数,如均一性红细胞(Isomorphic RBC)的百分比,非均一性红细胞(Dysmorphic RBC)的百分比,非溶血性红细胞的数量(Non-Lyse RBC#)和百分比(Non-Lyse RBC%);平均红细胞荧光强度(RBC- MFl),平均红细胞前向散射光强度(RBC-MFsc)和红细胞荧光强度分布宽度(RBC- Fl-DWSD)。
(1)红细胞及其相关参数的临床意义①红细胞数量变化的临床意义:显微镜计数法,正常人尿中红细胞约为<100万/24h;UF-100仪器法参考值为男性0-12/ul,女性0-24/ul;离心后为0-偶见/HPF(高倍视野),如每高视野均可见1-2个增多,≥3/HPF 为镜下血尿。
通过观察尿红细胞数量可帮助血尿有关疾病(如肾炎、膀胱炎、肾结石、肾结核等)的诊断和鉴别诊断;通过动态观察这种病人尿红细胞数量变化,可确定病人治疗的疗效观察和预后。
②泌尿道出血的定位:1979年Birch和Fairley 首先用相差显微镜观察红细胞形态变化,把血尿分肾小球血尿(简称肾性)和非肾小球血尿(简称非肾性)两大类,这种分类方法以后得到了许多学者赞同。
这种分类方法主要是根据红细胞形态的变化,将均一性的红细胞(红细胞形态基本与正常红细胞相似)归为非肾性血尿,非均一性的红细胞(红细胞形态大小不等)归为肾性血尿。
但显微镜检查法是通过人眼观察单个红细胞的形态,需要熟练的技术并受主观因素的影响。
UF-100全自动尿沉渣分析仪与尿干化学分析法、显微镜镜检联合检测尿白、红细胞结果分析【摘要】本文介绍了UF-100全自动尿沉渣分析仪与尿干化学分析法、显微镜检查联合检测尿白、红细胞结果分析的方法和优势。
首先分别介绍了UF-100全自动尿沉渣分析仪、尿干化学分析法和显微镜检查方法,并讨论了它们在尿白、红细胞检测中的应用。
随后分析了联合使用这三种方法的优势,包括提高检测效率和准确性、减少人工操作的影响等。
最后结论指出,UF-100全自动尿沉渣分析仪与尿干化学分析法、显微镜检查联合检测对尿白、红细胞结果分析具有重要的价值,能够帮助医务人员更准确地评估患者的病情,为临床诊断和治疗提供重要参考依据。
【关键词】尿沉渣分析仪、尿干化学分析法、显微镜检查、尿白细胞、尿红细胞、联合检测、结果分析、价值。
1. 引言1.1 研究背景尿液分析是临床诊断的重要手段之一,可以帮助医生了解患者的健康状况。
尿液中的白细胞和红细胞是常见的指标,对于肾脏疾病、泌尿系统感染等疾病的诊断具有重要意义。
传统的尿液分析方法包括尿液干化学分析和显微镜检查,这些方法需要耗费大量人力和时间,且存在着主观性较强的因素。
研发自动化的尿沉渣分析仪成为了迫切的需求。
1.2 研究目的研究目的:通过对UF-100全自动尿沉渣分析仪与尿干化学分析法、显微镜镜检联合检测尿白、红细胞结果的分析,探讨其在临床上的应用及准确性。
通过本研究可以进一步完善尿液检测技术,提高尿白、红细胞的检测水平,为临床医生提供更加准确、快速的诊断结果。
了解和探讨这些不同检测方法的优缺点,为临床医生选择合适的检测方法提供参考,进而提高尿液检测的准确性和可靠性。
最终,通过本研究的深入探讨,为临床医生提供更科学、准确的尿液检测方法,提高尿白、红细胞结果分析的准确率,为疾病的早期筛查和治疗提供科学依据。
1.3 研究意义研究意义是指针对于所研究问题的重要性、必要性和社会价值的阐释。
本文旨在探讨UF-100全自动尿沉渣分析仪与尿干化学分析法、显微镜镜检联合检测对尿白、红细胞结果分析的价值,通过系统比较分析不同检测方法的优缺点,为临床医师提供更准确、快速、便捷的尿液检测方案。
UF-100尿沉渣分析仪检测尿液白细胞、红细胞和管型的干扰因素研究作者:刘伟平殷明刚钟辉秀来源:《中国当代医药》2012年第09期[摘要] 目的探讨UF-100尿沉渣分析仪检测白细胞(WBC)、红细胞(RBC)和管型(CAST)的干扰因素。
方法对本院8 950例患者的中段晨尿标本用UF-100尿沉渣分析仪进行尿沉渣分析,并与显微镜镜检结果进行比较。
结果导致WBC、RBC、CAST检测出现假阳性的最主要因素分别为非晶形盐类、草酸钙结晶和粘液丝,分别占35.3%、40.1%、38.1%。
导致WBC、RBC、CAST检测出现假阴性的首位因素分别为白细胞聚集、影红细胞和少量透明管型,分别占59.2%、34.5%、100.0%。
结论尿沉渣分析仪检测干扰因素较多,应建立镜检复查标准和结果审核制度,以免临床误诊误治相关疾病。
[关键词] 尿沉渣分析仪;显微镜镜检;假阳性;假阴性[中图分类号] R446.12 [文献标识码] A [文章编号] 1674-4721(2012)03(c)-0077-02Study on the interference factors of detection of WBC,RBC,CAST by UF-100 urinary sediment analyzerLIU Weiping YIN Minggang ZHONG HuixiuLaboratory Department of Zigong First People's Hospital in Sichuan Province, Zigong 643000, China[Abstract] Objective To discuss the interference factors of detection of WBC, RBC, CAST byUF-100 urinary sediment analyzer. Methods 8 950 cases of midpiece morning urine samples were dectected by UF-100 urinary sediment analyzer and compared with manual microscopy. Results The main false positive factor of detection for WBC, RBC, CAST was ammonium salts (accounts for35.3%), calcium oxalate crystals (accounts for 40.1%), and viscose rayon (accounts for 38.1%) respectively. The main false negative factor of detection for WBC, RBC, CAST was WBC accumulation (accounts for 59.2%), shadow RBC (accounts for 34.5%) and hyaline cast (accounts for 100.0%) respectively. Conclusion Many interference factors exist in urine for detection of WBC, RBC, CAST by UF-100 urinary sediment analyzer. Therefore, microscopy review standards and result verifying system are supposed to be established to avoid clinical misdiagnosis and mistreatment.[Key words] Urinarysediment analyzer; Microscopy; False positive; False negativeUF-100型全自动尿沉渣分析仪是采用流式细胞技术和电阻抗技术,利用细胞染色技术对细胞核和细胞膜等成分进行染色,根据尿中各类有形成分产生的散射光脉冲和荧光脉冲的强度、持续时间的长短以及电阻抗信号的大小来区分尿内红细胞(RBC)、白细胞(WBC)、管型(CAST)等有形成分。
UF-100型尿沉渣全自动检测仪测定红细胞影响因素初探张巧红
【期刊名称】《江西医学检验》
【年(卷),期】2002(20)5
【摘要】UF-100型尿沉渣全自动检测仪对尿液中的有形成分直接进行荧光染色,利用流式细胞技术和电阻抗原理,识别尿液中的有形成分并进行计数。
在日常工作中,发现尿中大量细菌,结晶等存在时可影响红细胞的测定。
1 材料 1122份尿样随机取自我院门诊及住院病人送检标本。
UF-100及配套试剂、质控品均由日本东亚医用电子公司提供C 2 方法采取标本分装二个试管,每管10ml,一管按仪器操作规程在UF-100上机测定,另一管离心后进行尿沉渣显微镜检查。
3
【总页数】1页(P316-316)
【关键词】UF-100型尿沉渣全自动检测仪;测定;红细胞;影响因素
【作者】张巧红
【作者单位】浙江省东阳市人民医院检验科
【正文语种】中文
【中图分类】R446.12
【相关文献】
1.UF-100全自动尿沉渣分析仪对红细胞检测的影响因素分析 [J], 陈莹
2.UF-100型尿沉渣全自动检测仪测定红细胞影响因素初的探 [J], 张巧红
3.UF-100型尿沉渣检测仪测定红细胞影响因素的研究 [J], 樊爱琳;丁振若;郑善銮;
马静;杨麦贵;钟丽辉;郝晓珂
4.Uf-100全自动尿沉渣分析仪测定管型的影响因素 [J], 顾冬冬;任元芳
5.UF-100全自动尿沉渣分析仪对红细胞检测的影响因素分析 [J], 陈莹;
因版权原因,仅展示原文概要,查看原文内容请购买。
UF-100全自动尿沉渣分析仪检测尿液标本中红细胞、白细胞结果分析李亚红;罗燕婷【期刊名称】《黑龙江医学》【年(卷),期】2011(35)9【摘要】目的分析UF-100全自动尿沉渣分析仪检测尿中红细胞、白细胞的临床应用价值及其影响因素探讨.方法将UF-100全自动尿沉渣分析仪和DiaSys工作站镜检的红细胞、白细胞结果进行分析比较.结果两种方法检测红细胞的符合率为91.8%,白细胞的符合率为96.4%.经DiaSys镜检证实,UF-100全自动尿沉渣分析仪检测RBC假阳性率为25.5%,假阴性率为0,两者差异有统计学意义(P<0.05);检测WBC假阳性率为16.3%,假阴性率为0,两者差异有统计学意义(P<0.05).结论UF-100全自动尿沉渣分析仪与DiaSys镜检工作站符合率良好,但尿中红细胞、白细胞检测受多种因素影响,对UF-100检测结果异常者,UF-100全自动尿沉渣分析仪联合DiaSys镜检法,能大大提高检测结果的准确性.【总页数】3页(P657-659)【作者】李亚红;罗燕婷【作者单位】广东省佛山市顺德区第一人民医院检验科,广东,佛山,528300;广东省佛山市顺德区第一人民医院检验科,广东,佛山,528300【正文语种】中文【中图分类】R446.12【相关文献】1.尿液中红细胞、白细胞的UF-100尿沉渣分析仪和显微镜检测结果比较 [J], 何伟业;蓝红云;唐琼华2.Sysmex UF-100全自动尿沉渣分析仪检测红细胞、白细胞的性能评价 [J], 王正蓉;程树强;夏曙华;彭晓枫;王琴3.UF-100全自动尿沉渣分析仪对红细胞、白细胞检测的影响因素分析 [J], 罗燕飞;龚彩平;叶兆雄4.四种全自动尿沉渣分析仪对尿液中红细胞和白细胞的检测性能研究 [J], 梁骑;李君安;王东生;万松;费中海;吴昊;焦艳梅;唐中5.UF-100全自动尿沉渣分析仪检测尿液红细胞的应用 [J], 吴教仁;林敏;李扬因版权原因,仅展示原文概要,查看原文内容请购买。
UF-100型全自动尿沉渣分析仪在检测中的影响因素
李琳;徐传和
【期刊名称】《中华当代医学》
【年(卷),期】2007(13)6
【摘要】UF-100型全自动尿沉渣分析仪结合流式细胞技术与电阻抗原理,通过
测定前向散射色光、荧光的波幅和强度及电阻的变化报告12种参数,对尿液中的红细胞信息、红细胞、白细胞、上皮细胞、管型、细菌及电阻率等进行分析。
该仪器具有操作简便、检测快速、灵敏度高、重复性好等优点。
但是,也存在诸多影响因素(如草酸钙结晶、非晶形无机盐类、药物结晶、酵母样细胞、大量细菌、脂肪滴、卵磷脂小体、粘液丝、PH值、温度、大量小圆上皮细胞或扁平上皮细胞、黄疽尿及电压等)。
现将我们在实际工作中所遇到的诸多干扰现象作简要的分析探讨。
【总页数】2页(P82-83)
【作者】李琳;徐传和
【作者单位】吉林大学第二医院,吉林130041
【正文语种】中文
【中图分类】R446.12
【相关文献】
1.UF-100全自动尿沉渣分析仪对红细胞检测的影响因素分析 [J], 陈莹
2.Sysmex UF-100全自动尿沉渣分析仪检测尿红细胞影响因素分析 [J], 邱方城;
秦维超;李雅嫦;严礼华;陈娟
3.SySmex UF-100全自动尿沉渣分析仪对尿红细胞检测影响因素分析 [J], 金娣
4.UF-100全自动尿沉渣分析仪对红细胞、白细胞检测的影响因素分析 [J], 罗燕飞;龚彩平;叶兆雄
5.UF-100全自动尿沉渣分析仪对红细胞检测的影响因素分析 [J], 陈莹;
因版权原因,仅展示原文概要,查看原文内容请购买。
UF-100尿沉渣分析仪常见误差原因及其对策
王菁
【期刊名称】《中国疗养医学》
【年(卷),期】2010(019)005
【摘要】@@ Sysmex公司生产的UF-100尿沉渣流式细胞仪是利用尿沉渣中的有形成分DNA、细胞膜与菲啶、羰化氰两种荧光染料接触后通过鞘流进行激光照射,各形成分产生前向散射光强度和荧光脉冲宽度,又通过电阻抗测出血细胞的大小散实图、直方图,仪器可自动报告红细胞、白细胞、上皮细胞、管型、细菌5个定量参数及小圆上皮细胞、霉菌、病理管型、结晶及其精子5个定性参数,还可测出尿液电导率指标.但由于尿液成分的多样性、复杂性以及仪器本身检测的局限性,常导致某些检测项目的假阳性或假阴性结果,如果不予以及时发现和纠正,将会误导对疾病的诊断和治疗.
【总页数】2页(P456-457)
【作者】王菁
【作者单位】266071,济南军区青岛第一疗养院
【正文语种】中文
【相关文献】
1.UF-100尿沉渣分析仪检测红细胞结果的误差 [J], 章白苓;毕玉珍
2.UF-100全自动尿沉渣分析仪常见故障及对策 [J], 陈治水;袁蓉
3.UF-100流式尿沉渣细胞分析仪常见误差原因及分析 [J], 刘一君;沈大江
4.UF-100尿沉渣分析仪尿液有形成分检测假阳性结果原因分析及其对策 [J], 石
晶;赵敏;张家红;张丽霞
5.SYSMEX UF-100尿沉渣分析仪在尿液自动化检查中常见误差分析 [J], 刘祥红;岳晋巍;毛东英
因版权原因,仅展示原文概要,查看原文内容请购买。
UF-100检测前后段尿尿沉渣的差异
王成红;杨红梅;赵善娜
【期刊名称】《实用医技杂志》
【年(卷),期】2005(012)10A
【摘要】UF-100型自动流式尿有形成分自动分析仪是日本Sysmex公司近年推出的一套尿沉渣定量分析系统.它利用流式细胞原理.两个荧光染料染色.尿液沉渣成分不需离心自动检测,每小时可测100个标本,操作简易.并对红细胞、白细胞、上皮细胞、管型及细菌提供定量报告及散点图。
我们在临床实践中让就诊病人留取前段、后段尿用UF-100同时检测进行比较,发现女病人有明显差异。
现将检测结果报道如下。
【总页数】1页(P2835)
【作者】王成红;杨红梅;赵善娜
【作者单位】烟台市烟台山医院,山东烟台264000
【正文语种】中文
【中图分类】R446.12
【相关文献】
1.UF-100尿沉渣5-》析仪和显微镜检测尿中血细胞的比较分析 [J], 杨庆庚
2.UF-100尿沉渣流式细胞仪检测前后段尿尿沉渣差异的探讨 [J], 陈巧林;顾可梁;许燕萍;周志坚;陈阿琴
3.UF-100检测前后段尿尿沉渣的差异 [J], 王成红;杨红梅;赵善娜
4.前、中段尿对UF-100尿沉渣分析仪检测结果的影响 [J], 吴玉竹;邓莉;冯景;张
吉才;谭滢
5.前后段尿尿沉渣UF-100检测差异的探讨 [J], 郭书云;甄俊红
因版权原因,仅展示原文概要,查看原文内容请购买。