万全 TR350 3013 第一章 产品简介
- 格式:pdf
- 大小:285.62 KB
- 文档页数:5
No.N −110026Instruction ManualINDEXCaution .................................................................................................................2 Product View and Part Names ..............................................................................4 Installation and Detaching ....................................................................................7 Connection Method.............................................................................................10 Check the Operation............................................................................................12 Changing Method of Upper and Lower Limit Positions ......................................13 Troubleshooting...................................................................................................14 Product Specification ..........................................................................................14 Cleaning . (15)Thank you for purchasing TOSO products. To ensure safe use of this product,please read the following thoroughly and keep this manual stored.Caution∗ This manual contains cautions and instructions for safe use of the product.Please read it carefully before using to ensure appropriate use.This document illustrates the dangers of using this product without taking necessaryprecautions. Please refer to the symbols below for different types of safety points.This document illustrates safety points to be followed using the symbols below.Precautions upon installing the product (Please read before installation.)Safety in Use (Please read thoroughly)Product View and Part NamesProduct View·Part NamesAccessoriesBracket Split PinATF35 End Side BracketPole for Limit AdjustmentEnd Side BracketSplit PinTubular MotorAccessoriesBracketMT03 Bracket NPole for Limit AdjustmentOptional Parts (Sold separately)FM Remote-Control Transmitter 2.4GFM Remote-Control Receiver 2.4G16362FM Remote control connector (Powerful 4P type)TCU-TN3 Button SwitchOPENSTOPCLOSEInstallation and Detaching<Non Set Bar : with Side Brackets>Mounting Dimensions DrawingInstallation Method(1) Bracket Mounting PositionDetermine the End Side Bracket mountingposition, so that the dimension between the End Side Brackets is the same as the ordered product width.(2) Mounting of BracketsMount the End Side Brackets with screws.30 mm30 mmRoom side(3) Installing Roller PipeInsert the catch of the Tubular Motor into the Holder of the Brackets.Insert the Split Pin in the direction shown in theWhen uninstalling the Roller Pipe, pull out the Locking Pin, then remove the Roller Pipe.Split PinDetaching MethodInstallation Method<Set Bar type : with Brackets>Mounting Dimensions Drawing* The Brackets can be held temporarily, if the included Double-sided Tape for Temporary Positioning is used.Room side(1) Bracket Mounting PositionMount the Brackets in a position 4 to 7 cm fromeach end of the Set Bar.Detaching Method(1) While pressing the Release Button of theBracket 1), pull the Set Bar towards the (2) Mounting of BracketsMount the Brackets with screws so that theRelease Button is on the room side (front side).One screw per Bracket is used. The figure on the right is a dimensions drawing to the center of the oblong hole of the Bracket. There is also a round hole in the Bracket, use this hole according to the (3) Mounting of ProductHook the outer groove of the Set Bar on theFM Remote OperationBasic Connecting DiagramBasic Wiring DiagramVoltage: 220−230 VAC 50/60Hz Current: 0.53 AVoltage: 220−230 VAC 50/60Hz Current: 0.53 AFM Remote-Control Receiver 2.4GVoltage: 220−230 VAC 50/60Hz Current: 0.3 AFM RC Voltage: 220−230 VAC 50/60Hz Current: 0.3 ASimultaneous OperationBasic Wiring DiagramBasic Connecting DiagramCheck the Operation(1) Confirm that there is no miswiring of the wiring connections.(2) Turn ON the AC220−230 V power.(3) Operate each of the switches.OPENSTOPCLOSE(1) To roll up the Screen, press the OPEN button.(2) To stop the Screen in the middle, press the STOP button.(3) To roll down the Screen, press the CLOSE button.Operating Method of each Switch<For the 3 Button Switch>Register the address of the FM Remote-Control Receiver before using the transmitter.Refer to the Instructions Manual of the FM Remote-Control Transmitter 2.4G for the details.<For the FM Remote-Control Transmitter 2.4G>(1) Press Address No. setting button untilthe LED indicates the Address No. of the product you operate.(If ALL is indicated, all of the transmitter can operate at the same time)button is pressed during operation, the product stops operating.* Refer to the Instructions Manual of the FM Remote-Control Transmitter 2.4G for the details.Adress No. LED indicator lamp Address No. setting button Open button Stop button Close buttonChanging Method of Upper and Lower Limit PositionsLeft Side (Motor on left)On front, viewed from front of main body For setting upper limit On back, viewed from front of main bodyFor setting lower limitRight (Motor on right)For setting lower limit For setting upper limitThe range for rolling up and down (upper/lower limits) the Screen in the up and down directions hasbeen preset for this product, according to the product dimensions ordered by the customer. When changing the upper and lower limit positions, use the following procedures to change the positions.The Limit Switch for setting the upper and lower limits, is located on the lower portion of the cord extending from the Motor.There are two Limit Switches. The upper limit and lower limit differs depending on whether the cord is extended from the right or left side of the Motor Controller.Changing Method of Upper and Lower Limit PositionsLimit Switch(1) Insert the Pole for Limit Adjustment into the Limit Switch for setting the upper limit (on the back side when viewed from front of main body for the motor on the right, and front side for the Motor on the left).(2) When the Pole for Limit Adjustment is turned in the "+" direction, the upper limit setting will raise. When turned in the "-" direction, the upper limit setting will lower.<When adjusting Upper Limit>(1) Insert the Pole for Limit Adjustment into the Limit Switch for setting the lower limit (on the front side when viewed from front of main body for the motor on the right, and back side for the Motor on the left).(2) When the Pole for Limit adjustment is turned in the "+" direction, the lower limit setting will lower. When turned in the "-" direction, the lower limit setting will raise.<When adjusting Lower Limit>TroubleshootingProduct does not operate.PhenomenonProbable Cause and ActionsScreen moves in oppositedirection of the operating direction.Power not turned ON in various controllers. Connect the various controllers to AC220−230 V . Upper and lower limit positions are set in the same position.Reset the positions according to P .13 "Changing Method of Upper and Lower Limit Positions". Various controllers are not connected correctly to switches and/or the interior wiring. Reconnect the controller according to P .10 "Connection Method".Various controllers are not connected correctly to switches and/or the interior wiring.Reconnect the controller according to P .10 "Connection Method". Various controllers are not connected correctly to switches and/or the interior wiring.Reconnect the controller according to P .10 "Connection Method".Product does not operate sometimes.Check the following items before determining that there is trouble with the product.Product SpecificationATF35-RB Motor SpecificationRated Voltage Power Supply FrequencyRated Current Power Consumption Rotation Speed Rated TorqueOperating Ambient TemperatureTime Rating50Hz23.5rpmAC 220−230V +/- 10%0.53A 121W3Nm -10−40 4 Minutes60Hz27rpmCleaningWhenever necessary, wipe the product with dry, clean, and soft cloth.Refrain from directly applying water, thinner or other chemicals to the product. Those materialsmay cause damages, discoloring, and distortion to the product.。
Motor control and protectionICON familyStart easily Protect preciselyIntroducing Eaton’s new contactor range for AC-3 applications to 170A. Perfectly suited for applications in the commercial and industrial segments for panel builders and machinery OEMs.The contactor has a smaller footprint than the existing xStart series and offers application adjusted ratings.Icon Contactors SeriesCoil voltages available are 24V50/60HZ, 110V50/60HZ, 230V50/60HZ, 400V50/60HZ, DC24V .Basic devices Rated operational current Max. motor rating for three-phase motors 50 - 60 Hz Conventional thermal current I th = I e AC-1at 40°C A Open Contact AC-3AC-3AC-4380 V 400 V I e220 V 230 V P 380 V 400 V P 660 V 690 V P 220 V 230 V P 380 V 400 V P 660 V 690 V P N/O = Normallyopened contact N/C = Normally 4 pole, 3 poleConnection type: Screw terminals9 2.5 4 4.5 1.5 2.5 3.6 20 – 1 N/C 12 3.5 5.5 6.5 2 3 4.4 20 1 N/O –12 3.5 5.5 6.5 2 3 4.4 20 – 1 N/C 15 4 7.5 7 2 3 4.4 20 1 N/O –154 7.5 7 2 3 4.4 20 – 1 N/C 3 poleConnection type: Screw terminals1857.511 2.5 4.56.5 401 N/O–18 5 7.511 2.5 4.5 6.5 40 – 1 N/C 257.51114 3.5 68.5 401 N/O–25 7.5 1114 3.5 6 8.5 40 – 1 N/C 32101515 4 710 451 N/O–32 10 1515 4 710 45 – 1 N/C 381118.515 4 710 451 N/O–3811 18.5 15 4 710 45 – 1 N/C 3 poleConnection type: Screw terminals40 12.5 18.523 5 912 60 1 N/O 1 N/C 50 15.5 2230 6 1014 80 1 N/O 1 N/C 65 20 3035 7 1217 98 1 N/O 1 N/C 7222 3735 7 1217 98 1 N/O 1 N/C 3 poleConnection type: Screw terminals80 25 3737112015110 1 N/O 1 N/C 95304545 1120151301 N/O1 N/C3 poleConnection type: Screw terminals115 37 5590 17 2843 160 ––150 48 75 96 20 3348 190 ––1705290140 20 3348 203––CMN00027DILM9-01N CMN00038DILM12-10N CMN00049DILM12-01N CMN00060DILM15-10N CMN00071DILM15-01N CMN00082DILM18-10N DILM18-01N CMN00104DILM25-10N DILM25-01N(CMN00126DILM32-10N DILM32-01N CMN00148DILM38-10N DILM38-01N CMN00170DILM40-11N DILM50-11N DILM65-11N DILM72-11N DILM80-11N DILM95-11N DILM115N DILM150N DILM170N (...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)(...)• Phase failure sensitivity and temperature compensation • Reset pushbutton manual/auto • Test/off pushbutton• Auxiliary contact (1 N/O + 1 NC)•Fitted directly on the contactor of the maximum current to 175AIcon Overload relays ZB..N series0.1 – 0.16CMN00333CMN00335ZB12N-1,6CMN00336ZB12N-2,4CMN00337ZB12N-4CMN00338ZB12N-6CMN00339ZB12N-10CMN00340ZB12N-12CMN00341ZB12N-161 – 1.5CMN00352ZB32N-24CMN00353ZB32N-30CMN00354ZB32N-36CMN00355ZB32N-38CMN00356Setting range of overload releasesCircuit symbolAuxiliary contactFor use withI r AN/O = normally open contact N/C = normally closed contact0.4 – 0.6 1 N/O 1 N/C 0.6 – 1 1 N/O 1 N/C 1 – 1.6 1 N/O 1 N/C 1.6 – 2.4 1 N/O 1 N/C 2.4 – 4 1 N/O 1 N/C 4 – 6 1 N/O 1 N/C 6 – 10 1 N/O 1 N/C 9 – 12 1 N/O 1 N/C 12 –161 N/O1 N/C 17 – 24 1 N/O 1 N/C 22 – 30 1 N/O 1 N/C 29 – 36 1 N/O 1 N/C 33 – 381 N/O1 N/COverload relaysIcon Overloads ZB…N seriesSetting range of overload releasesCircuit symbolAuxiliary contactFor use withI r AN/O = normally open contact N/C = normally closed contact63 – 80 1 N/O 1 N/C 77 – 971 N/O1 N/C50 – 70 1 N/O 1 N/C 70 – 100 1 N/O 1 N/C 95 – 125 1 N/O 1 N/C 120 – 150 1 N/O 1 N/C 145 – 1751 N/O1 N/COverload relays Part no.Article no.– 25CMN00363– 50– 35– 25 – 50ZB95N-50 – 35ZB150N-35Icon Contactor Relays DILA…N seriesWiring method: Screw terminals Basic devices with interlocked opposing contacts ContactRated operational current AC – 15Conventional thermal current at 55°CN/O = Normally opened contact N/C = Normally closed contact220 V 230 V 240 V I e A380 V 400 V 415 V I e AI th A4 N/O – 4 416 3 N/O 1 N/C 4 4 16 2 N/O 2 N/C 4 4 16 1 N/O 3 N/C 4416–4 N/C4416DILA-40N DILA-31N DILA-22N DILA-13N DILA-04N(Coil voltages available are 24V50/60HZ, 110V50/60HZ, 230V50/60HZ, 400V50/60HZ, DC24V .• Varied 4-pole contact configurations • Conventional thermal current (Ith): 16A• Identical construction sizes for AC- and DC-operated contactor relays •Integrated surge suppressors for DC-operated contactor relaysA complete range of accessories are available for the Icon series, such as:• Auxiliary contacts (top mount)• Auxiliary contacts (side mount)• RC Suppressors• Varistor Suppressors• Pneumatic timer modules • Mechanical Interlocks • Sealable Shrouds•External Reset Button(...)(...)(...)(...)(...)E a t o n10 Kent RoadMascot NSW 2020Tel: 1300 332 866Fax: (02) 9693 1258Email: ************************ Eaton is a registered trademarkof Eaton Corporation.All trademarks are property of their respective owners.For more information about Eaton visit: Eaton’s mission is to improve the quality of life and the environment through the use of power management technologies and services. We provide sustainable solutions that help our customers effectively manage electrical, hydraulic, and mechanical power – more safely, more effi ciently, and more reliably. Eaton’s 2019 revenues were $21.4 billion, and we sell products to customers in more than 175 countries. We have approximately 95,000 employees.For more information about Eaton visit: 。
产品手册Product manual三一工程掘进机SANY ENGINEERING ROADHEADERQUALITY CHANGES THE WORLD企业简介三一重装工程掘进机STR368/7三一重装工程掘进机STR318/6三一重装工程掘进机STR260/6三一重装工程掘进机STR318/5三一重装工程掘进机STR260/5三一重装工程掘进机STR200Z/4三一重装除尘风机施工案例售后服务企业简介BRIEFINTRODUCTION 创新研发三一重装研究院下设采掘研究院、智能化研究院、宽体车项目部、纯水支架项目部和破碎装备项目部,现已被认定为国家级企业技术中心、国家级高新技术企业,拥有国家级博士后科研工作站、行业第一家院士工作站、省级工程中心及省级工程实验室,连续四年被评为煤机行业“双十佳”企业,通过了CNAS(国内)与ANAB(国际)双重信息安全认证。
企业愿景秉持“创建一流企业,造就一流人才,做出一流贡献”的企业愿景,肩负“品质改变世界”的企业使命,秉承“自强不息,产业报国”的企业精神,三一重装致力于为全球矿产资源生产企业的绿色、安全、高效开采提供成套设备,成为其最值得信赖的长期合作伙伴,为中华民族贡献一个世界级品牌。
三一重型装备有限公司创立于2004年,是一家专业从事矿山机械、煤炭掘、采、运成套设备研发、制造及销售的大型装备制造企业,是全球装备制造头部企业三一集团旗下的核心事业部。
2009年11月25日三一重装的母公司三一国际在香港联交所主板成功上市,成为国内首家在香港上市的煤机制造企业。
主导产品覆盖综掘、采煤机、液压支架、刮板机、宽体车、矿车和破碎设备等产品门类50余种型号。
产业布局经过17年的创新发展,三一重装作为一家全球化公司,目前产品远销俄罗斯、印度、印度尼西亚、巴西、阿根廷、乌克兰、波兰、南非等20余个国家和地区。
在国内设立13个分公司,销售服务覆盖全国1000余家矿山企业。
350CT3508Designed to Explore"Plug & Play" MMSThe Philips 350 is packed with 100 great pictures that you can use for MMS or as screensavers/wallpaper!Add Emotion to your MessagesMMS starter kit with large picture libraryMMS (Multimedia Messaging Service)Maximize your Multimedia Experience4096 colors for a vivid display32-tone rich polyphonic melodiesHighlightsMMS starter kitMMS starter kit with large picture library is a database of fun pictures stored in the phone that you can use to send fun MMS (Multimedia Messaging Service) messages. Create an MMS, then link a picture from the library to send to friends and family.MMS messagingMMS (Multimedia Messaging Service) allowsyou to use your mobile phone to send andreceive pictures, video, and audio files withyour text messages.4K color display4K color display uses RGB color synthesistheory to bring you vivid pictures and otherimages for a more enjoyable experience.32-tone polyphonic melodies32-tone polyphonic melodies can createsimultaneous tones of different notes usingMIDI format for more natural and realisticmusical results, sounding just like a smallorchestra of different instruments foroutstanding sound effects.SpecificationsPicture/DisplayDiagonal screen size (inch): 1.1 inchLines of text: up to 8Main Display Colors: 4096Main Display Resolution: 128x128 pixelMain Display Technology: CSTNSoundRingers: Polyphonic (32 tones)Audio PlaybackAudio supported formats: ADPCM, AMR, Midi, SP-MidiAudio RecordingRecording time: upto 60 secondsAudio CapturingVoice recording: Yes, AMRStill Picture PlaybackPicture Compression Format: BMP, GIF (87a & 89a), JPEGStill Picture CapturingCamera: As accessoryDigital zoom: x2Image sensor type: CMOSPicture file format: JPEGPicture Mode: Economy, Normal, Super fine Picture resolution: VGA (640x480)Special effects preview mode: Grey scale, SepiaStorage MediaBuilt-in memory (RAM): 8User memory: 1.5 MBConnectivityHeadphone: 2.5 mmSynchronisation PC organizer: Lotus Notes, MS OutlookConvenienceButtons and controls: 4-way navigation key and enter, Customized hot keyCall Management: Call Cost, Call Counters, Call Forwarding, Call on Hold, Call Time, Call Waiting*, Caller ID*, Conference Call, Emergency Call, Explicit Call Transfer, Microphone mute, Missed Calls, Multi-party call, Received Calls Clock/Version: Analogue, DigitalEase of Navigation: Animated Caroussel,Color CarousselEase of Use: Hot Keys, Keypad Lock, ScreenSaver Digital Clock, Vibra AlertEase To Experience: Demo ModeEmbedded Games: 3Games and applications: Agenda, AlarmClock, Calculator, Calendar, Euro Converter,Infusio - Exen v2Language available: T9 input: ChineseSimplified, Chinese Traditional, Czech, Danish,Dutch, English, Finnish, French, German,Greek, Italian, Norwegian, Polish, Portuguese,Spanish, Swedish, TurkishLanguage available: UI: Chinese Simplified,Chinese Traditional, Czech, Danish, Dutch,English, Finnish, French, German, Greek,Hebrew, Hungarian, Indonesian, Italian,Lithuanian, Norwegian, Polish, Portuguese,Romanian, Russian, Slovak, Spanish, Swedish,Thai, TurkishMultimedia: BeDJPersonal Info Management: Daylight saving,Time Zone, Smart Phonebook, Vcard ExchangePersonalisation/Customization:Downloadable Animated GIF, DownloadablePicture, Downloadable Ringtones, Fotocall,Screen Saver, WallpaperSpeech Recognition: Conversation Recording,Voice Command, Voice Dial, Voice Memo,Voice RecognitionVolume controlAccessoriesOptional accessories: Battery 720 mAh,Cigarette lighter adapter, Deluxe headset,Universal car kit, USB Jack Cable, VGA rotatingcolor cameraStandard Package Includes: Battery, Charger,Handset, International Guarantee, Necklace,SAR information leaflet, User ManualDimensionsAntenna: IntegratedForm Factor: Candy barHandset Color: Black Gum, Blue Gloss, SilverLight, Silver SilverHandset dimensions: 106 x 46 x 18 mmHandset volume: 72 ccHandset weight: 82 gPowerBattery Capacity: 720 mAhBattery Type: Lithium-ionCharging time: less than 2 hours hrStandby time: up to 400 hrsTalk time: up to 4 hoursNetwork FeaturesVoice Codec: FR/EFR/AMRGPRS (Rx+Tx): Class 10 (4+2), Class BMessaging: Concatenated SMS (Long SMS),E-mail, EMS / release 4, MMS,MultimediaMessage Service, Predefined messages(SMS,MMS), Quick SMS, SMS CB (CellBroadcast), SMS (Short Message Service)Services: WAP 1.2.1, WAP Browser Teleca2.0,SIM Toolkit / Release 99, OTA provisioning(WAP,MMS)© 2019 Koninklijke Philips N.V.All Rights reserved.Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.Issue date 2019‑10‑23 Version: 2.0.312 NC: 9961 400 03749 。
第五章常用操作系统安装指南本章主要介绍目前常用操作系统的安装步骤及注意事项常用的操作系统包括1Windows 2000 Advanced Server简体中文版2Windows NT SERVER 4.0简体中文版3RedHat Linux 7.24SCO Unixware 7.11注意安装操作系统之前请务必先阅读操作系统安装前的准备说明做好必需的驱动备份操作系统安装时需要的驱动程序将随导航软件光盘提供一般使用前都先要备份到软盘上备份方法有如下2种1如果您有一台运行Windows 95/98或Windows 2000简体中文版的机器可以将导航光盘放入光驱中按提示信息找到所需的驱动程序并根据提示信息将驱动程序备份到格式化过的3.5英寸空白软盘上例如Windows NT Server4.0 安装所需的网卡驱动程序2如果您没有Windows系统的机器可以用导航光盘引导服务器到导航软件DOS 版根据菜单选项将驱动程序备份到格式化过的3.5英寸空白软盘上驱动程序备份的详细操作方法请参见随导航软件附带的联想万全服务器导航软件用户手册以下安装指南适合于万全T3503005配置服务器5.1 Windows 2000 Advanced Server 中文版安装指南本指南适合于在万全T3503005配置上第一次安装Windows 2000 Advanced Server有关安装的详细说明请根据您的实际需要参看购买的Windows 2000 Advanced Server操作系统用户手册本安装指南仅供参考一安装前的准备工作参照导航软件的使用说明从随机配置的导航软件光盘上把安装Windows 2000 Advanced Server所需的网卡驱动程序备份到一张新3.5” 软盘上贴标签并注明网卡驱动程序for Windows 2000二 安装步骤1将Windows 2000 Advanced Server系统光盘放入光驱引导系统当屏幕底部出现Press any key to boot from CD..的字样时请按空格键或回车键从光驱启动2出现蓝色的欢迎使用安装程序的界面回车继续参看附图5-1-1附图5-1-2附图5-1-13出现WIN2000 许可协议界面按<F8>键接受许可协议并继续下一步安装参看附图5-1-24按系统提示及您的需要划分磁盘空间并执行格式化操作和复制文件例如创建一个5G的主分区参见附图5-1-3- (1) 至附图5-1-3- (6)(1) 附图5-1-3- (2)附图5-1-3-注由于所配置的硬盘不同所以附图5-1-3- (2)显示的硬盘容量会不同(1)要求选择使用哪种文件格式推荐使用NTFS选择它并回车参见附图5-1-3- (4)(3) 附图5-1-3- (4)附图5-1-3-注由于所配置的硬盘不同所以附图5-1-3- (3) 显示的硬盘容量会不同(2)开始格式化硬盘主分区参见附图5-1-3- (5)(3)完成格式化分区后系统检测磁盘并开始复制系统文件参见附图5-1-3- (6)(5) 附图5-1-3- (6)附图5-1-3-5文件复制完成后系统将在15秒后自动重新启动重新启动之后出现安装向导的图形界面单击下一步继续参见附图5-1-4附图5-1-4 附图5-1-56Windows2000 Advanced Server安装程序开始检测和安装设备参见附图5-1-57在区域设置中选择默认设置即可点击下一步继续参见附图5-1-6附图5-1-6 附图5-1-78输入用户名和单位名点击下一步继续参见附图5-1-79输入产品密钥然后点击下一步继续参见附图5-1-8附图5-1-8 附图5-1-910按实际需要选择每服务器或每客户方式的授权方式在此推荐选择前者点击下一步继续参见附图5-1-911设置计算机名和管理员密码参见附图5-1-10附图5-1-10 附图5-1-1112根据需要选择Windows 2000安装组件点击下一步继续参见附图5-1-1113进行适当的日期设置点击下一步继续参见附图5-1-12附图5-1-12 附图5-1-1314这时Windows 会自动安装一些必要的组件等待一段时间参见附图5-1-1315最后出现提示您已成功地完成了Windows 2000的安装将光盘以及软盘取出点击完成参见附图5-1-14附图5-1-1416操作系统安装完成后需要安装Windows 2000 Server Service Pack 2如果不安装有些设备的驱动程序将无法安装系统也将会不稳定三Intel Chipset Software安装1进入Windows 2000 Advanced Server系统后将导航光盘放入光盘驱动器中出现引导安装界面2参照导航软件的使用说明在驱动程序及工具功能模块中机型选择万全T350 3005,操作系统选择Windows 2000 Advanced Server, 驱动程序选择chipset,然后点击右方的安装驱动图标,启动安装程序3根据安装提示单击下一步4同意许可协议单击是5出现自述文件界面单击下一步6安装开始拷贝文件完成后根据提示重启计算机7系统安装完成后需要安装Windows 2000 Server Service Pack 2如果不安装有些设备的驱动程序将无法安装系统也将会不稳定四网卡驱动程序安装1单击开始Æ设置Æ控制面板,双击系统图标2出现系统特性界面选择硬件项点击设备管理器弹出设备管理器界面双击以太网控制器出现以太网控制器属性界面3选择重新安装驱动程序出现升级设备驱动程序向导对话框点击下一步继续4系统提示您期望向导做什么选择搜索适于我的设备的驱动程序(推荐)然后点击下一步继续5系统提示可选的搜索位置仅选择软盘驱动器并插入标有网卡驱动程序ForWindows 2000的软盘然后点击下一步继续6安装程序向导显示找到设置驱动程序,点击下一步继续7等待系统拷贝文件完成后,点击完成关闭安装程序8返回到Intel(R) PRO/100S Server Adapter对话框点击关闭完成了网卡驱动程序的安装9对系统检测到的另一块网卡进行同样操作即可10系统安装完成后建议再次安装Windows 2000 Server Service Pack 25.2 Windows NT Server4.0中文版安装指南本指南适合于在万全T3503005配置上第一次安装Windows NT Server4.0有关安装的详细说明请根据您的实际需要参看购买的Windows NT Server4.0操作系统用户手册本安装指南仅供参考一安装前的准备工作参照导航软件的使用说明从随机配置的导航软件光盘上把安装Windows NT Server 4.0所需的网卡驱动程序备份到两张新3.5” 软盘上把SCSI卡驱动程序备份到一张新3.5” 软盘上贴标签并分别注明网卡驱动程序for Windows NT 4.0 #1网卡驱动程序for WindowsNT 4.0 #2和SCSI卡驱动程序for Windows NT 4.0注意对于Windows NT Server4.0的安装请务必进行如下操作1在开始安装Windows NT Server4.0前在系统启动POST过程中当屏幕显示联想Logo 时根据提示按DEL键进入BIOS SETUP右移动光标到Advanced选择PCI/PnPConfiguration将NT4 Installation Workaround 设置为Enabled2安装完NT后一定要安装SP SP5以上版本然后再到BIOS里将NT4 InstallationWorkaround设置为disabled二安装步骤1将Windows NT Server4.0安装光盘放入光驱从光盘引导服务器2当系统开始从光盘引导屏幕上方显示Setup is inspecting your computer’s hardwareconfiguration时按<F6>键注意一定要在此时按下<F6>键参见附图5-2-1附图5-2-1附图5-2-23当安装程序提示Setup could not determine the type of one or more mass storage devices installed in your system or you have chosen to manually specify an adapter时按S键加载设备驱动程序参见附图5-2-24出现Select the SCSI Adapter you want from the following list……界面选择Other出现插入软盘的提示将备份的SCSI卡驱动程序for Windows NT 4.0的软盘插入软驱回车确定参见附图5-2-3附图5-2-3 附图5-2-4 5出现的列表中选择Adaptec Ultra160 Family PCI SCSI Controller (NT 4.0)并按回车确定参见附图5-2-4 6 出现提示Setup will load support for the following mass storage device (s)界面按回车键继续系统加载SCSI 卡驱动程序参见附图5-2-5附图5-2-5 附图5-2-6 7出现欢迎使用安装程序的界面按回车键继续参见附图5-2-6 8 出现提示安装程序检测到下列大容量存储设备界面按回车键继续参见附图5-2-7附图5-2-7 附图5-2-8 9 系统提示安装程序检测出系统存在一个或若干个含有多于1024柱面的硬盘时直接按回车键继续参见附图5-2-8 10系统提示安装程序已检测出计算机的启动硬盘是新的或被清除过的……时按<C>键继续参见附图5-2-9附图5-2-9 附图5-2-1011出现Windows NT 许可协议界面阅读完许可协议按<F8键>同意许可协议并继续参见附图5-2-1012出现安装程序检测出计算机内含有下列硬件和软件组件界面确认系统检测到的软硬件组件按回车键继续参见附图5-2-11附图5-2-11 附图5-2-12- (1)13出现下列列表中显示出已有的磁盘分区以及可用于创建新磁盘分区的空间界面时根据您的需要划分磁盘空间并根据系统提示执行格式化操作和复制文件例如创建一个4G的硬盘主分区参见附图5-2-13- (1) 至附图5-2-13- (8)(1) 出现下列列表中显示出已有的磁盘分区以及可用于创建新磁盘分区的空间界面时按<C>键继续参见附图5-2-12- (1)(2) 附图5-2-12- (3)附图5-2-12-注由于Windows NT 4.0的安装程序无法识别大容量硬盘所以将硬盘的容量识别为8033MB因此附图5-2-12-(1)以及附图5-2-12-(2)显示的硬盘容量与实际不符(2)系统提示输入创建分区的大小输入4000后按回车键继续参见附图5-2-12- (2)(3) 返回到下列列表中显示出已有的磁盘分区以及可用于创建新磁盘分区的空间界面确认无误后按回车键继续参见附图5-2-12- (3)附图5-2-12- (4) 附图5-2-12- (5) 注由于Windows NT 4.0的安装程序无法识别大容量硬盘所以将硬盘的容量识别为8033MB 因此附图5-2-12-(3)显示的硬盘容量与实际不符(4) 出现您所选择的是一个新创建的且未格式化的磁盘分区界面要求选择使用哪种文件格式推荐使用NTFS 选择它并回车键继续参见附图5-2-12- (4)(5) 开始格式化硬盘主分区参见附图5-2-12- (5)(6) 完成格式化分区后系统提示安装程序在硬盘上安装WindowsNT 文件请选择用来安装这些文件的位置时本安装指南以采用系统默认值为例按回车键继续参见附图5-2-12- (6)附图5-2-12- (6) 附图5-2-12- (7)(7) 出现现在安装程序将检测硬盘界面本安装指南以选择允许安装程序在硬盘上执行这种检测为例按回车键继续参见附图5-2-12- (7)(8) 安装程序开始拷贝文件到硬盘参见附图5-2-12- (8)附图5-2-12- (8) 附图5-2-13 14文件拷贝完成后根据提示取出软盘安装光盘按回车键继续参见附图5-2-13 15系统启动之后将自动进行文件格式的转换然后再次重新启动16在系统重新启动后系统提示插入安装光盘时插入安装光盘确定出现安装向导的图形界面点击下一步继续参见附图5-2-14附图5-2-14 附图5-2-1517出现名称和组织界面请输入相应的信息然后点击下一步继续参见附图5-2-1518出现注册界面请输入Windows NT 4.0 Server产品的CD码然后点击下一步继续参见附图5-2-16附图5-2-16 附图5-2-1719出现许可协议方式界面请根据实际情况配置本安装指南以选择每服务器有个同时连接为例点击下一步继续参见附图5-2-1720出现计算机名称界面请输入计算机名然后点击下一步继续参见附图5-2-18附图5-2-18 附图5-2-1921出现服务器类型界面请根据实际情况配置本安装指南以选择主域控制器为例点击下一步继续参见附图5-2-1922出现管理员帐号界面输入管理员密码后并确认然后点击下一步继续参见附图5-2-20附图5-2-20 附图5-2-2123出现紧急修复磁盘界面建议选择是创建一张紧急修复磁盘(推荐)然后点击下一步继续参见附图5-2-2124出现选择组件界面请根据实际情况配置本安装指南以安装系统默认的组件为例点击下一步继续参见附图5-2-22附图5-2-22 附图5-2-2325出现安装Windows NT网络界面点击下一步继续参见附图5-2-2426出现Windows NT 需要知道本计算机与网络的连接方式界面请根据实际情况进行配置本安装指南以选择用线路连接到网络为例点击下一步继续参见附图5-2-25附图5-2-24 附图5-2-2527出现Microsoft Internet Information Server 允许您本身的Intranet或Internet从该服务器上共享信息界面请根据实际情况进行配置本安装指南以不选择此项为例点击下一步继续参见附图5-2-25附图5-2-26 附图5-2-2728出现要让安装程序开始搜索网络适配器……界面时点击从列表中选择参见附图5-2-2629出现选定网络适配器界面点击从磁盘安装参见附图5-2-27附图5-2-28 附图5-2-2930系统提示请插入软件或硬件厂商提供的软件软盘……时将备份的网卡驱动程序for Windows NT 4.0 #1软盘插入软驱后回车注意一定要使用从导航光盘上备份的网卡驱动程序来安装参见附图5-2-2831出现请选择硬件厂商提供的软盘所支持的软件界面时选择Intel R PRO Adapter 后点击确定按钮参见附图5-2-29附图5-2-30 附图5-2-3132返回到要让安装程序开始搜索网络适配器……界面时确认所要安装的网络适配器正确无误点击下一步继续参见附图5-2-3033根据实际情况选择所要安装的网络协议点击下一步确认参见附图5-2-3134出现系统将安装下列服务界面请根据实际情况进行配置本安装指南以系统默认值为例点击下一步继续参见附图5-2-32附图5-2-32 附图5-2-3335出现Windows NT 准备安装选定的和其他系统所需的网络组件……界面点击下一步继续参见附图5-2-3336进行文件复制的过程中屏幕上会出现提示请插入软盘Intel PRO Adapter floppy disk 2into A将备份的网卡驱动程序for Windows NT 4.0 #2软盘插入软驱单击确定37出现提示如果网络上存在DHCP服务器……时请根据实际情况进行配置本安装指南以选择否为例参见附图5-2-34附图5-2-34 附图5-2-3538出现Microsoft TCP/IP属性对话框请根据实际情况进行设置TCP/IP地址网关等完成后点击确定参见附图5-2-3539出现使用该页禁止网络绑定或重排计算机查找网络信息的顺序界面请根据实际情况进行配置本安装指南以系统默认值为例点击下一步继续参见附图5-2-36附图5-2-36 附图5-2-3740出现Windows NT 准备启动网络以完成网络安装界面点击下一步继续参见附图5-2-3741出现已请求Windows NT 创建一个主域控制器界面请根据实际情况进行配置本安装指南以系统默认值为例点击下一步继续参见附图5-2-38附图5-2-38 附图5-2-3942出现Windows NT 安装程序界面点击完成继续参见附图5-2-39附图5-2-40 附图5-2-4143出现日期/时间属性对话框请根据实际情况进行配置本安装指南以系统默认值为例点击下一步继续参见附图5-2-4044系统提示系统在计算机上找到以下显示适配器时点击确定然后再点击取消参见附图5-2-41附图5-2-42 附图5-2-4345安装程序开始拷贝文件到硬盘参见附图5-2-4246系统提示请将一张磁盘粘贴[紧急修复磁盘]标签……时根据提示操作将一张3.5’’软盘插入软驱点击确定继续参见附图5-2-43附图5-2-4447系统提示已成功安装Windows NT 4.0时根据提示取出软盘和光盘然后按回车键继续系统将重新启动参见附图5-2-4448安装WINDOWS NT SERVICE PACK 6A如果不打补丁有些设备的驱动程序将无法正常安装系统也可能会不稳定三显卡驱动程序的安装1进入NT系统后将导航光盘放入光盘驱动器中出现引导安装界面2参照导航软件的使用说明在驱动程序及工具功能模块中机型选择万全T350 3005,操作系统选择Windows NT Server4.0 ,选择驱动选择Graphics,然后点击右边的安装驱动图标,启动安装程序3根据提示完成安装重启计算机5 3 SCO UnixWare 7.1.1安装指南本指南适合于在万全T3503005配置上第一次安装SCO UnixWare 7.1.1有关安装的详细说明请根据您的实际需要参看购买的SCO UnixWare 7.1.1操作系统用户手册本安装指南仅供参考一安装前的准备工作参照导航软件的使用说明从随机配置的导航软件光盘上把安装SCO UnixWare 7.1.1所需的SCSI卡网卡驱动程序和PTF程序各备份到一张新的且格式化好的3.5” 软盘上贴标签并注明SCSI卡驱动程序for UnixWare 7.1.1网卡驱动程序for UnixWare 7.1.1和PTF 程序for UnixWare 7.1.1从随机配置的导航软件光盘上制作2张启动软盘分别标注UnixWare 7.1.1 启动盘#1和UnixWare 7.1.1 启动盘#2二安装步骤5将UnixWare 7.1.1 启动盘#1放入软驱中引导服务器系统6系统提示选择安装语言类型本安装指南以选择Proceed with installation in English按回车继续参看附图5-3-1附图5-3-1 附图5-3-2 7根据提示插入UnixWare 7.1.1 启动盘#2到软驱中 8出现Welcome to UnixWare 7Release 7.1.1界面按<F10>键继续参看附图5-3-2 9出现Choose a zone for this system and press <F10>界面根据需要进行选择本安装指南以选择Other 为例按<F10>键继续参看附图5-3-3附图5-3-3 附图5-3-4 10 出现Choose a locale for this system and press <F10>界面根据需要进行选择本安装指南以选择 C (English)为例按<F10>键继续参看附图5-3-4 11 出现Keyboard 选择对话框根据需要进行选择本安装指南以选择United States为例按<F10>键继续参看附图5-3-5附图5-3-5 附图5-3-6 12系统提示键入License(序列号及激活码)键入后按<F10>继续参看附图5-3-6 系统提示插入HBA 驱动盘将SCSI 卡驱动程序for UNIXWARE7.1.1软盘插入软驱然后按<F10>继续注操作系统自带的HBA 软盘不要添加系统提示是否安装其他 的HBA 盘选择Proceed with installation9系统进入硬件自检和配置界面选择Do not enter the DCU 回车 10 系统提示输入“System Node Name”, 完成输入后, 按<F10>继续11系统提示“Installation Method”, 选择“Install from CD-ROM”,并将Unixware711第一张光盘放入光驱<F10>继续12屏幕出现“Disk Configuration”界面, 用户可根据需要选择分区大小安装按<F10>继续13系统提示是否改变文件系统的类型与大小, 本指南以选择“Use default filesystem sizes and types”为例按<F10>继续14系统提示“Choose to customize surface analysis, boot block, and disk geometry options.”时, 本指南以选择“Use default disk options”为例按<F10>继续15系统提示“Choose System Profile”, 本指南以选择“License-Based Defaults”为例按<F10>继续16系统提示Select Network Adapter”选择Defer network configuration17进行系统时间以及日期的设置按<F10>继续18进入choose the desired security level”选择Traditional”后按<F10>19进入System owner name”正确输入主机名和密码后按<F10>20系统提示输入root的密码2遍按<F10>继续21系统进入License Agreement”界面选Accept按<F10>继续22系统开始拷贝文件23安装过程中要求插入PTF盘插入PTF程序for UnixWare 7.1.1软盘回车继续24系统提示安装成功回车后选择继续安装25系统提示重新插入Ultra160 Driver for Unixware 7.1.1插入SCSI卡驱动程序forUNIXWARE7.1.1盘按回车继续26继续安装直到结束取出Unixware第一张光盘回车重新启动系统27重启后系统继续安装选择鼠标类型(PS/2并进行测试28系统提示To continue installing the system please insert CD-ROM #2 and press<F10>”插入第二张安装光盘按<F10>继续29根据需要用空格键选择相应的安装包回车开始安装30安装完第二张光盘后系统会提示是否安装第三张光盘第三张光盘上是一些附加的服务包请根据需要选择安装31继续安装直到结束并重启系统32系统启动后开始进行补丁包的安装以下进行字符界面的补丁包的安装33首先安装SMP的补丁包具体操作如下切入字符界面以ROOT身份登录系统将第一张系统光盘放入光驱在#后键入命令# mount -F cdfs –r dev/cdrom/cdrom1 /mnt# pkgadd –d /mnt osmp按照屏幕提示回车继续安装34安装结束后按照屏幕上的提示重新升级UNIXWARE在#后键入命令# pkgadd –d /mnt update711按照屏幕提示回车继续安装安装完之后在#后键入命令# shutdown –y –g0按照屏幕提示重新启动系统35系统启动后切入字符界面以ROOT身份登录系统将导航光盘装入光驱在#后键入命令# mount -F cdfs –r dev/cdrom/cdrom1 /mnt# mkdir /patch# cp /mnt/commom/patch_uw/uw711m1.im /patch# cat /patch/uw711m1.im |pkgadd –d –出现提示Select package(s) you wish to process (or ‘all’ to process all packages). (default:all) [?,??,quit]:键入all,回车系统自行开始安装安装结束后键入# shutdown –y –g0重新启动系统完成安装注如果您不想保留uw711m1这个补丁包您可以使用rm –fR 命令删除此目录36进入系统后将网卡驱动程序for UnixWare 7.1.1软盘插入软驱37在字符界面下输入# mount –F dosfs /dev/fd0 /mnt# cp /mnt/eee8.pkg /tmp# pkgadd –qd /tmp/eee8.pkg all# netcfg38在出现的硬件配置窗口中点击菜单Hardware选择Add new LAN adapter39随后出现的网卡选择对话框中选择Ethernet Intel Pro/100+eeE8 2.3.12添加第一块网卡用户可根据实际需要添加相关的网络协议并进行设置40用同样的步骤添加第二块网卡5.4 RedHat Linux 7.2安装指南本指南适合于在万全T3503005配置上第一次安装RedHat Linux 7.2有关安装的详细说明请根据您的实际需要参看购买的RedHat Linux 7.2操作系统用户手册本安装指南仅供参考一安装前的准备工作将1张新3.5英寸软盘格式化后贴上标签注明网卡驱动程序for Redhat 7.2参照导航软件的使用说明从随机配置的导航软件光盘上把万全T3503005配置服务器的网卡驱动程序for Linux 备份到贴标签的软盘上二安装步骤一图形界面安装步骤1将标识有RedHat Linux 7.2安装光盘#1放入光驱使系统从光驱引导2光盘启动后出现 RedHat Linux 7.2安装程序的欢迎界面在boot后直接回车进行安装参见附图5-4-1附图5-4-1 附图5-4-23按照系统提示设置安装语言点击Next继续参见附图5-4-24按照系统提示设置键盘的类型点击Next继续参见附图5-4-3附图5-4-3 附图5-4-45按照系统提示设置鼠标的类型点击Next继续参见附图5-4-46出现Welcome界面点击Next继续参见附图5-4-57系统提示选择Installation Type时可根据实际需要选择本安装指南以选择Custom安装方式为例点击Next继续参见附图5-4-6附图5-4-5 附图5-4-6附图5-4-7 附图5-4-88出现Disk Partitioning Setup界面本安装指南以选择Manually partition with Disk Druid为例点击Next继续参见附图5-4-79如果所使用的硬盘上无任何分区则系统出现提示The partition table on device hda was unreadable. To create new partitions it must be initialized, causing the loss of ALL DATA on this drive.选择Yes参见附图5-4-8附图5-4-9 附图5-4-10-(1)注由于所配置的硬盘不同所以显示的硬盘容量会不同10根据实际需要进行添加分区参见附图5-4-9例如创建一个512MB的交换分区100MB的boot分区和一个5GB的/分区(1) 点击New出现附图5-4-10-(1)界面点击Filesystem Type旁边的ext3从中选择swap然后在Size (MB) 一栏中输入交换分区的大小本安装指南以创建一个512MB的交换分区为例完成后点击OK(2) 返回到Disk Setup界面并且显示出刚刚创建的交换分区参见附图5-4-10-(2)(3) 点击New出现附图5-4-10-(3)界面点击Mount Point旁边的下拉框从中选择/然后在Size (MB) 一栏中输入根分区的大小本安装指南以创建一个5GB的根分区为例完成后点击OK(4) 点击New出现附图5-4-10-(3)界面点击Mount Point旁边的下拉框从中选择/boot然后在Size (MB) 一栏中输入根分区的大小本安装指南以创建一个100MB的分区为例完成后点击OK附图5-4-10-(2) 附图5-4-10-(3)(5) 返回到Disk Setup界面并且显示出已经创建好的交换分区以及根分区参见附图5-4-10-(4)确认无误后点击Next继续附图5-4-10-(4) 附图5-4-1111出现Boot Loader Configuration界面根据需要进行配置点击Next继续参见附图5-4-1112出现Boot Loader Password Configuration界面根据需要进行设置为了提高安全性建议设置密码完成后点击Next继续参见附图5-4-12附图5-4-12 附图5-4-1313出现Network Configuration界面根据实际情况进行配置完成配置后点击Next 继续参见附图5-4-1314出现Firewall Configuration界面根据实际情况进行配置以No firewall为例完成配置后点击Next继续参见附图5-4-14附图5-4-14 附图5-4-1515出现Additional Language Support界面根据需要进行选择点击Next继续参见附图5-4-1516出现Time Zone Selection界面设置所在的时区完成选择后点击Next继续参见附图5-4-16附图5-4-16 附图5-4-1717出现Account Configuration界面进行设置系统管理员口令以及添加用户完成后设置后点击Next继续参见附图5-4-1718出现Authentication Configuration界面根据实际情况进行配置完成配置后点击Next继续参见附图5-4-18附图5-4-18 附图5-4-1919出现Package Group Selection界面根据实际需求进行选择安装的软件包本指南以选择Everything为例点击Next继续参见附图5-4-1920出现Graphical Interface (X) Configuration界面选择ATI Rage XL点击Next继续参见附图5-4-20附图5-4-20 附图5-4-21注由于所配置的显卡不同所以显示的显卡类型以及显存容量会不同21出现About to Install界面点击Next继续参见附图5-4-2122出现Installing Packages界面系统开始格式化分区进行文件拷贝参见附图5-4-22附图5-4-22 附图5-4-23注由于主机配置不同而且根据选择的软件包不同所以显示的状态会不同23出现Boot Disk Creation界面时根据提示制作启动软盘本指南以选择Skip boot disk creation为例点击Next继续参见附图5-4-2324出现Monitor Configuration界面一般情况下Red Hat可以检测出当前显示器的型号点击Next继续参见附图5-4-24附图5-4-24 附图5-4-2525出现Customize Graphics Configuration界面根据需要进行设置点击TestSetting可进行测试完成设置后点击Next继续参见附图5-4-2526最后取出软盘光盘点击Exit系统将重新引导参见附图5-4-26附图5-4-2627系统重新启动后以root的身份登录字符界面下修改网卡驱动28将标有网卡驱动程序 FOR Linux的软盘插入软驱在字符界面键入mount /dev/fd0 回车29在字符界面键入cp /mnt/floppy/e100-1.8.37.tar.gz /tmp回车30在字符界面键入cd /tmp回车31在字符界面键入tar xfz e100-1.8.37.tar.gz 回车32在字符界面键入cd e100-1.8.37/src/ 回车33在字符界面键入make install 回车34在字符界面键入 netconf 回车35选择Host name and IP network devices, 再选择Adaptor 1将Kernel module 中的eepro100改为e10036接下来您选择Adaptor 2将Kernel module 中的eepro100改为e100并且可以进行IP等网络属性的设置37更改结束以后您要单击Accept再把Network configurator窗口关掉即可38保存并退出39重新启动操作系统安装结束二字符界面安装步骤1将Redhat Linux 7.2安装光盘放入光驱使系统从光驱引导2光盘启动后出现 Redhat Linux 7.2安装程序的欢迎界面立即在boot后键入text 回车注意不要在出现boot提示后停顿太久否则系统会自动进入下一界面而导致进入图形界面安装3按照系统提示设置安装语言设定键盘鼠标的类型4当出现Red Hat Linux界面时选择OK5系统提示选择Installation Type时可根据实际需要选择(使用上下箭头来选择)选择结束后按TAB键选中OK进入下一步安装本安装指导以Custom System安装方式为例6出现Automatic Partitioning根据需要使用Disk Druid或fdisk进行硬盘分区设置本手册以Disk Druid为例进行分区7出现Partitioning界面时选择new回车8在Add Partition界面的下拉菜单中选择swap将光标移至size上输入相应的交换分区大小以512MB为例。
φ3.0×13m水泥磨一、水泥磨有关技术参数及性能1、规格:φ3.0×13m2、生产能力:45t/h(42.5普通碳酸盐水泥,圈流,入料粒度≤25mm,入料水份≤0.5%,入料温度≤50℃,比表面积≥340m2/kg)3、磨机转速:18.92r/min4、主电机:(重电)型号:YR1400-8/1430 功率:1400kW 转速:740r/min电压:10KV5、主减速机:(南高齿)(1)型号:JDX900 速比:7.1(2)传递功率:1400KW(3)磨机筒体转速:18.92r/min6、慢速驱动装置(1)电机型号:YEJ225M-6(2)电机功率:30kW(3)电机转速970r/min(4)辅助减速机型号:ZSY315-1/ll输入转速970r/min 速比:1:1007、油站(主减速机厂家配套)8、冷却方式:水冷9、润滑方式(稀油站GDR-A2×2.5/50南方润滑)(1)低压系统流量:50L/min 供油压力:0.4MPa供油温度:40±3℃电机:Y112M-6 2.2kW 380V(2)高压系统泵型号:10SCY14-1B流量:2.5L/min供油压力:32MPa电机:Y112M-4 4kW 380V(3)其它性能油冷却器GLCQ3-7-0.63公称压力:0.63MPa冷却面积:7m2进水温度:<28℃加热器功率:SRYZ-220/4 功率4KW 220V工作介质:N33-N32011、设备重量:183t(不含传动装置及研磨体)二、主要零部件、材质1、筒体 Q235-B δ=32mm2、滑履轴承:下座 HT250瓦体HT250瓦衬(巴氏合金ZchSnSb11-6)3、衬板:中铬合金4、稀油站 GDR-A2×2.5/50(南方)5、控制柜及起动柜三、供货范围1、回转部分1套2、进料装置1套3、滑动主轴承装置(含轴瓦)2套4、出料装置1套5、衬板及双隔仓装置1套6、主电机 YR1400-8/1430 1400KW/10KV(重电)1台7、主减速机 JDX900(含油站)1台8、慢速驱动装置1套9、稀油站 XGD-A2×2.5/50 2只10、控制柜(含高压控制、低压起动、稀油站控制)1台11、联轴器1台套12、地脚螺栓1套。
User's Guidee-mail: ************** GPIB HARDWARE MANUAL FOR USE WITHPCI-GPIB, ISA-GPIB142.6 CPCI-GPIB (12)2.5 PC104-GPIB (11)2.4.2 Windows 3.1 (11)2.4.1 Windows 95 (10)2.4 PCM-GPIB (8)2.3 ISA-GPIB/LC (6)2.2 ISA-GPIB (5)2.1 PCI-GPIB (5)CHAPTER TWO: INSTALLATION ...................31.2.3 Connection Configurations . (2)1.2.2 GPIB Electrical Signal Configuration (1)1.2.1 Talkers, Listeners, and Controllers (1)1.2 GPIB SYSTEM DESCRIPTION (1)1.1 HISTORY (1)CHAPTER ONE: INTRODUCTION ......................Chapter One: INTRODUCTION1.1 HISTORYThe GPIB (General Purpose Interface Bus) has become the worldwide standard for connecting instruments to computers. Invented in the 1960s by Hewlett Packard and originally designated as HPIB, the bus specification was eventually adopted by a wide variety of both instrument and computer manufacturers. The original specification was documented and sanctioned by the Institute of Electrical and Electronic Engineers as IEEE-488.The advent of the inexpensive and powerful personal computer has driven the GPIB market through explosive growth. As GPIB bus usage expanded, there arose the need for some additional capability and standardization, so in 1987, IEEE-488.2 was adopted. IEEE-488.2 was revised/ammended in 1992 and represents the current GPIB specification. The new specification provides some standardization among compliant instruments. These standardization greatly simplifies the job of the GPIB system designer since 488.2 compliant instruments share common programming conventions.1.2 GPIB SYSTEM DESCRIPTION1.2.1 Talker s, Listeners, and ControllersA GPIB device can be a Talker, Listener, and/or Controller. As the name implies a Talker sends data to one or more Listeners, A Listener accepts data from a Talker and a Controller manages the flow of information over the bus. A GPIB Digital Voltmeter is acting as a Listener as its input configurations and ranges are set, and then as a Talker when it actually sends its readings to the computer.The Controller is in charge of all communications over the bus. The Controller’s job is to make sure only one device tries to talk at a time, and make sure the correct Lis-teners are paying attention when the Talker talks. Each GPIB system has a single sys-tem controller. The system controller is ultimately in charge of the bus, and is in control as the bus is powered up. There can be more than one Controller on the bus and the System Controller can pass active control to another controller capable device, though only one can be Controller In Charge at a given time. TheGPIB board is usually designated as the System Controller.1.2.2 GPIB Electrical Signal Configuration1The GPIB is an 8-bit parallel data transfer bus. In addition to the 8 data bits, the bus carries three handshaking lines and five GPIB specific management and control lines. The remainder of the standard 24 pin GPIB cable is used for the cable shield, signal grounds and returns. The GPIB connector pin-out is shown in the diagram below:Standard GPIB Cable/ConnectorDATA LINESDIO1 through DIO8 are the data transfer bits. Most GPIB systems send 7-bit data and use the eight bit as a parity or disregard it entirely2HANDSHAKING LINESThere are three handshaking lines that control the data transfer between devices.NRFD (Not Ready For Data): this bit is used to indicate the readiness (or lack thereof) of a device to accept dataDAV (Data Valid): bit is used to indicate to receiving devices that data has been placed on the bus and is available to read.NDAC (Not Data Accepted): is asserted by the receiving device to indicate that data has been read and may now be removed from the bus.SYSTEM MANAGEMENT LINESATN (Attention): is used by the controller to specify how data on the DIO lines is interpreted and which devices must respond to the dataIFC (Interface Clear): is used by the system controller to place the entire system in a known quiescent (Cleared) state and to assert itself as Controller In Charge (CIC).SRQ (Service Request): is used by a device on the bus to indicate the need for atten-tion and requests an interrupt of the current event sequence.REN (Remote Enable): is used by the controller in conjunction with other messages to place a device on the bus into either remote or local modeEOI (End or Identify): Is used by Talkers to indicate the end of a message string, or is used by the Controller to command a polling sequence.1.2.3 Connection ConfigurationsThe GPIB specification is quite definitive regarding the number of devices and cable lengths allowed in a GPIB system. There can be no more than 15 devices on a single contiguous GPIB bus. Larger systems are possible by installing additional GPIB inter-face boards in your computerThe maximum, total length of all cables on a single GPIB system is 20 meters. In addition, cable length between consecutive devices may be no greater than 4 meters, and average cable length must be 2 meters or less. Stated another way, the total cable length (in meters) in the system may not be longer than 2 times the number of devices (up to 20 meters). Longer length systems are possible, but only with the use of a GPIB extender card.In addition to the above rules, at least two thirds of all devices on the bus should be powered on for proper operation.3Keeping the above constraints in mind, there is no limitation on the actual connection scheme used to connect the GPIB devices together. Star, Linear or any combination of both may be used. These are shown in the following diagrams.4,QVWUXPHQW &,QVWUXPHQW ',QVWUXPHQW $,QVWUXPHQW %Linear C onnectionC onfiguration ,QVWUXPHQW ',QVWUXPHQW &,QVWUXPHQW (,QVWUXPHQW $,QVWUXPHQW %S tar C onnectionC onfigurationChapter Two: INSTALLATION The following sections describe the hardware installation procedure for GPIB boards. After hardware installation, please refer to your GPIB software installation guide for additional setup and operation details.2.1 PCI-GPIBThe PCI-GPIB board is completely plug and play. To install this board into your sys-tem follow the simple steps shown below.1. Turn your computer off2. Open your computer case3. Insert the PCI-GPIB into any available PCI slot4. Put your computer’s case back on.5. Turn your computer back on, and follow the instructionsin the GPIB software manual you received with your board.52.2 ISA-GPIBThe only hardware configuration required prior to installing the ISA-GPIB/LC is set-ting the board’s Base Address switch. The location of the Base Address switch is shown in the photograph above, while the switch itself is shown in the diagram on the following page.Most computers will have Base Address 300 Hex (768 decimal) free and the default setting of the board is 300 Hex. If there is already a board in your system using address 300 HEX (768 Decimal), you will have to change the board’s base address prior to installing it in your computer. Other typically free addresses include 310 Hex and 330 Hex.6The following diagram shows the base address in its default 300 Hex setting.987 6 5 4S V65LThe address values corresponding to each of the switches are shown in the following table.Hex Dec.Switch Value Value Default9 200 512 up (200 Hex)8 100 256 up (100 Hex)7 80 128 down (0 Hex)6 40 64 down (0 Hex)5 20 32 down (0 Hex)4 10 16 down (0 Hex)-----------------total 300 HexNote: On this base address switch, Up is on, Down is off. This con-figuration is the opposite of most ISA baseddata acquisition boards.72.3 ISA-GPIB/LCThe following diagram shows the base address in its default 300 Hex setting.987654S V65LThe address values corresponding to each of the switches are shown in the following table.Hex Dec.Switch Value Value Default9200512up (200 Hex)8100256up (100 Hex)7 80128down (0 Hex)6 40 64down (0 Hex)5 20 32down (0 Hex)4 10 16down (0 Hex)-----------------total300 HexNote: On this base address switch, Up is on, Down is off. This con-figuration is the opposite of most ISA based data acquisitionboards.92.4 PCM-GPIBThe installation procedure is different for Windows 95 and DOS/Windows 3.1. These procedures are described below:10:LQGRZVThe PCM-GPIB board is completely plug and play. There are no switches or jumpers to set prior to installation in your computer. Simply follow the steps shown below to install you PCM-GPIB hardware. Once your hardware is installed, please refer to the GPIB-488.2 software manual.1. Start Windows 952. Insert the card into a free PC Card/PCMCIA slot. You do not have toturn the computer off. The system is designed for power on installation.3. Windows 95 will automatically detect the card and depending on theversion of Windows 95 you have, you will either see a New HardwareFound dialog box or a Update Device Driver Wizard box.4. Insert PCM-GPIB Disk 1 into your A drive and follow the instructionsprovided by the dialog box/wizard..If no New Hardware Found dialog box appears, check that you computer’s 32-bit PCMCIA drivers are enabled. This can be checked using the following Windows 95 sequence. Start>Settings>Control Panel>System and look in Performance section. It should read 32-bit. If not, enable 32-bit, shut down your computer and try the above procedure again.:LQGRZVMost users are now installing boards on systems with at least Windows 95 operating systems. However, if you wish to install the PCM-GPIB board in a machine running Windows 3.1 and/or DOS, you will need to use the DOS based Card & Socket serv-ices routine. This is included with most newer computers. However, if you need to purchase these routines, they are available as part number PCM-C&SS from Com-puterBoards for a nominal price. To run the C&SS installation routines, place the PCM-C&SS disk in drive a:, from your boot drive (usually C:) type A:Install and hit enter. Then simply follow the instructions on your screen.The PCM-GPIB hardware is completely plug and play. There are no switches or jumpers to set prior to installation in your computer. Once your hardware is installed, please refer to the GPIB-488.2 software manual.112.5 PC104-GPIBThe only hardware configuration required prior to installing the ISA-GPIB/LC is set-ting the board’s Base Address switch. The location of the Base Address switch is shown in the photograph above, while the switch itself is shown in the diagram on the following page.Most computers will have Base Address 300 Hex (768 decimal) free and the default setting of the board is 300 Hex. If there is already a board in your system using address 300 HEX (768 Decimal), you will have to change the board’s base address prior to installing it in your computer. Other typically free addresses include 310 Hex and 330 Hex.12The following diagram shows the base address in its default 300 Hex setting.987654S V65LThe address values corresponding to each of the switches are shown in the following table.Hex Dec.Switch Value Value Default9200512up (200 Hex)8100256up (100 Hex)7 80128down (0 Hex)6 40 64down (0 Hex)5 20 32down (0 Hex)4 10 16down (0 Hex)-----------------total300 HexNote: On this base address switch, Up is on, Down is off. This con-figuration is the opposite of most PC104 based data acquisitionboards.132.6 CPCI-GPIBThe CPCI-GPIB board is completely plug and play. To install this board install this board into you system follow the simple steps shown below.1. Turn your computer off2. Open your computer front panel (if enclosed)3. Insert the CPCI-GPIB into any available 3U CPCI slot4. Put your computer’s case back on (optional).5. Turn your computer back on, and follow the instructionsin the GPIB software manual you received with your board.14EC Declaration of ConformityDescriptionPart Number Computer to GPIB interface Computer to GPIB interface Computer to GPIB interface Computer to GPIB interface Computer to GPIB interface Computer to GPIB interface ISA-GPIBISA-GPIB/LCPCI-GPIBPC104-GPIBPCM-GPIB CPCI-GPIBto which this declaration relates, meets the essential requirements, is in conformitywith, and CE marking has been applied according to the relevant EC Directives listedbelow using the relevant section of the following EC standards and other normativedocuments:EU EMC Directive 89/336/EEC : Essential requirements relating to electromagneticcompatibility.EU 55022 Class B : Limits and methods of measurements of radio interferencecharacteristics of information technology equipment.EN 50082-1: EC generic immunity requirements.IEC 801-2: Electrostatic discharge requirements for industrial process measurementand control equipment.IEC 801-3: Radiated electromagnetic field requirements for industrial processmeasurements and control equipment.IEC 801-4: Electrically fast transients for industrial process measurement and controlequipment.Carl Haapaoja, Director of Quality Assurance。
Models: RPR3006W RadiPower ®Product ManualRF Power MetersPage 2 of 19RadiPower® product manualThis product manual pertains to the RadiPower®.Models: RPR3006W - RPR3008W - By Raditeq 16/08/21All trademarks used in this manual are the property of their respective ownersSupplier InformationRaditeq B.V.Vijzelmolenlaan 33447 GX, WoerdenThe NetherlandsTel.: +31 (0)348 200 100Internet: Email: *****************Read this manual carefully before operating the product and make sure all the safety instructions are strictly followed.For your convenience, a Quick Start Guide has been added to this product. This Quick Start Guide contains the basic start-up steps and the safety warnings.Please keep the Quick Start Guide (and this regular manual) close at hand when you operate your new Raditeq product(s).Please contact your local reseller if you have any questions.Table of contentsWARNINGS & PRECAUTIONS 4 Introduction 5 The RadiPower® Series 6 Product characteristics 6 Functional description 7 The RadiPower® 3000 Series 8 Model RPR3006W 8 RadiPower® Installation 9 Stand-alone Configuration 9 Software Configuration 10 How to configure the RadiPower® in RadiMation® 10 How to connect the RadiPower® to the RadiCentre® 11 How to check whether the RadiPower® is properly connected to RadiMation® 11 Adding coupler values in RadiMation®12 Theory of operation in burst mode 13 Prefix & Communication example: 13 Remarks about the general commands 14 Stand-alone command set 14 Burst Mode 15 Specifications RPR3006W16 Warranty Conditions18Page 3 of 19WARNINGS & PRECAUTIONSRead the contents of this product manual carefully and become familiar with the safety markings, the product instructions and the handling of the system. Please refer to the applicable product manual(s) for further information regarding the operation and control of the product(s).Only Raditeq qualified maintenance personnel is allowed to perform maintenance and/or repair service on the equipment.This product® contains materials that can be recycled and reused to minimize material waste. At the ‘end-of-life’, specialized companies can dismantle the discarded system to collect the reusable and recyclable materials. If your product is at its ‘end-of-life’, please return it to your local reseller or to Raditeq for recycling.For cleaning, use a clean, dry cloth (or a damp cloth where needed) and wipe the surface of equipment.This product contains no hazardous substances as described in the RoHS Directive (2015/863/EU).This product contains embedded software, which is field upgradeable.For more information contact your local reseller or go to Page 4 of 19IntroductionThis manual contains information about the RadiPower® RPR3006W RF power meters.An accurate power meter is indispensable to perform reliable EMC measurements. The RadiPower® is a RF power meter especially designed for power measurements during EMC tests. The RadiPower® is an affordable, accurate and fast power meter. It provides accurate measurements over a wide frequency range, which enables effective measurements in accordance with the latest EMC standards.Please read this manual carefully and make sure to pay special attention to the chapters regarding your new product(s).RadiCentre® SystemThe RadiCentre® is a modular EMC/RF test system that serves as the interface between user and computer for all the RadiCentre® plug-in cards and modules.RadiMation® SoftwareRadiMation ® is the EMC software package from Raditeq used for remote controland automated testing of the RadiCentre® plug-in cards and modules and is sold separately. RadiField® Electric Field GeneratorThe patented RadiField® Triple A is no less than a revolution in EMC immunity testing.A complete paradigm shift involves a combination of high-level integration anda field combining technique, making several discrete components like combiner,coupler, power meters and cabling superfluous. This product is sold separately.RadiMationShielded USB cable Model: USB A male to USB mini B5 male.To connect the RF power sensor to a USB connector.The RadiPower® 3000 SeriesMMCX Trigger cable For measurements on multiple ports.RadiPower® RF power sensor Model: RPR3006W.Supporting documentation is supplied on a USB stick containing:•The (digital) User Manual and Quick Start Guide.•The installation of RadiMation® Free software and drivers.• Optional - The calibration certificate for the power meter.The RadiPower® RF power sensor is optimized for EMC measurements, where a high dynamic range, together with fast measurements, are required even at low power levels. Where most power sensors require long measurement times at low RF levels, the RadiPower® RF power sensor is able to perform accurate power measurements, with a high measurement speed, at power levels close to the noise floor, without the need for zero adjustment!Fast - EMC immunity measurements are time consuming. This is mainly dependent on the number of frequency points, the dwell time and the speed of the power meter. As the first two parameters are generally prescribed by standards, the only one that can be optimized is the speed of the power meter. The unprecedented detector technology of Raditeq’s power meters makes extremely fast and accurate power measurements a reality, even at low power levels.Accurate - Accuracy is another concern in addition to speed, when performing EMC measurements. The RadiPower® allows for high precision EMC measurements with a large dynamic range. Because the RadiPower® has a high accuracy over the complete band, it is suitable for measurements in accordance to automotive, military, telecom and EMC basic standards such as the IEC61000-4-3/6 standards.Simultaneous power measurements on multiple ports - The RadiPower®RPR3006W has two trigger ports (MMCX) which can be used to synchronizemultiple power meters. These power meters connected through a daisy chaintrigger each other to make time synchronized measurements. Due to this functionmeasurements of WLAN and/or MIMO devices according to the EN 300 328 andEN 301 893 standards.All necessary parameters can be set and calculated by RadiMation® Free (or ahigher version) making the setup and measurements effortless.Low measurement uncertainties - Impedance mismatches contribute to themeasurement uncertainty. The RadiPower® has a very low Standing Wave Ratio(SWR) and as a result, measurement uncertainties are low compared to othercontributions in the EMC measurement setups.Robust housingThe RadiPower® RF power sensor is mounted in a rugged metal housing to ensure a long life and excellent RF shielding. The power sensor is equipped with an N-type precision RF input connector and a mini USB-B connector for communication with a computer.Easy to use - With the USB interface the RadiPower® is easy to use. In addition, the RadiPower® can be controlled by both the RadiMation® integral EMC measurement software and any other EMC measurement packages, because all the software commands needed to control the unit are available. For ‘stand-alone use’ of the RadiPower®, RadiMation® Free measurement software is delivered with the power meters. The RadiPower® 3000 SeriesProduct characteristicsFunctional descriptionThe RadiPower® uses a high speed power detector to measure the RF signal, independent of the crest factor of the input signal waveform. The detected signal is sampled, at high speed, by a high speed ADC and the samples are processed by a powerful DSP. The sophisticated software enables unique functions, such as envelope tracing and burst logging. The table below shows which models support the different measurement modes.0 : CW1 : Peak √√2 : Envelope tracing√3 : Burst√CW modeThe RadiPower® performs RMS power measurements of CW-signals. In RMS mode the RadiPower® samples the signal at high speed. The RMS value of the power is calculated over the number of samples defined by the filter setting and can be read by a simple command. Due to the high sampling speed the number of readings is high, even at large filter settings. This mode is supported for all the RadiPower® models.Peak modePeak mode keeps track of the maximum power that is measured during a specific time interval. In PEAK mode, the “power?”-command will return the highest value that was measured since the last “power?”-command. After each cycle of the command the previous peak value is cleared,Burst modeIn burst mode, the RadiPower can measure a burst of RF power. It is even possible to measure a burst on multiple powermeters at the sime time (using the MMCX trigger ports). The power readings of each powermeter can be combined to a total power by RadiMation according to the EN 300 328 and EN 301 893 standards..In this mode the sample speed can be set to either 1 MS/s or 5 MS/s. The RadiPower can store a total of 100.000 bursts and is independent of the observation time. The stored data of a single burst consists of the RMS power and the start/stop-time of the burst. The start and stop time are defined by how long the power was higher than the threshold value. The threshold value can be set in RadiMation.The RMS power of a burst is calculated according to the following formula:Where m is the number of RMS power samples within the start and stop time. When measuring on a MIMO device with more than one port. It is possible to use multiple power meters. The burst values of each power meter can be combined to a single RF power using RadiMaiton. This can also be done manual by using the following formula:i is the number of power metersIt is also possible to add corrections for the coupler, beamforming gain (Y) and the assembly gain (G) of the DUT. RadiMation can compensate for these values.Connect the RadiPower® sensor to a Windows computer with a USB port for ‘stand-alone’ use. Use the supplied USB cable to connect the sensor to your computer. Windows will prompt that new hardware has been found. The USB-driver for the RadiPower® is Windows certified and will be loaded automatically from the Windows update. If the drivers are not loaded automatically, these can be installed manually from the supplied USB-key. Follow the normal instructions from Windows to install the drivers manually.Once the drivers are loaded successfully, the RadiPower® will be shown in the device list.RadiPower® InstallationStand-alone Configuration Connect the RadiPower® sensor to a Windows computer with a USB 2.0 compatible port. Use the supplied USB cable to connect the RadiPower® sensor. The hardware installation for the RadiPower® sensor is now complete.Software ConfigurationIn order to control the RadiPower® from a computer, the RadiMation® EMC software package can be used. RadiMation® from Raditeq is sold separately. A free version of RadiMation® is available on: https://www. /automated-emc-software/radimation-free/.If the RadiPower® is operated manually, this chapter can be skipped.The RadiPower® device driver is part of the Power Meter Device Driver familyHow to configure the RadiPower® in RadiMation®1. Start the latest version of RadiMation®; https:///radimation-download/2. Select the button ‘Device’ at the top menu bar, followed by clicking ‘Configure’;3. In the configuration screen select ‘Device Drivers’ and Select ‘Power meter’ or any of the otherdrivers as driver type;4. Click the ‘Add’ button to open the selection of available drivers in RadiMation®;5. Enter ‘RadiPower’ in the search bar which will show all available RadiPower® drivers;6. Select the correct driver, double click it (Optional, rename it) and press ‘OK’.2354How to check whether the RadiPower® is properly connected to RadiMation®1. Select ‘Devices’ in the top menu bar2. Open ‘Device Drivers’ and select device driver type: ‘Power Meter’3. Double click the recently configured RadiPower® or click ‘Edit’.4. Finally select the ‘Check’ button on the right side of the opened screen.5. When correctly configured, RadiMation® will notify you that the device is correctly installed.23Adding coupler values in RadiMation®In a MIMO test setup, power measurements are often performed using a coupler on the antenna port. Coupling factors can be compensated by RadiMation® using a correction file. If no couplers or additional attenuators are used in the setup, there is no need to create and apply these correction files.To create a correction file, select “File” – “New” – “Correction” from the menu bar.Press “Colums/units” to create to columns for Frequency and Attenuation.To create a constant correction versus frequency:• Press “Add Row” and enter the lowest frequency with the corresponding attenuation.• Press “Add Row” again and enter the highest frequency with the corresponding attenuation.If calibration data of the coupler is available, this data can be used to create an accurate correction for the coupler.After all data has been entered, select “File” – “Save Correction As” to save the data.Next, the correction data of the coupler has to be added to the correct power meter. Select “Configuration” and “Configuration” again. In the Configuration window select the “Device drivers” tab and select the power meter for which the correction has to be added. Press “Edit”.Press the “file open”- button in de Correction Files area to select the correction file. Perform this procedure for each power meter for which a coupler correction has to be added. RadiMation® will now automatically calculate the power values, including the coupler values.Stand-alone command setCommunication with the RadiPower® sensor is possible using a virtual COM-port (VCP)For more information see chapter ‘stand alone configuration’.NOTE: All commands can be found in the RadiCentre® Manual under the programming manual.Specifications RPR3006W & RPR3008W1. In burst mode only 1 and 5 MS/s can be set and used.• All specifications are measured after 10 minutes warm-up time and 0dBm unless specified otherwise.• T ypical specifications indicate that the measured values a re met on at least 80% of the points.• Three years warranty will be granted only after you register the product at . Without registration, a 1 year warranty period applies.For more information about the current and new Raditeq products at:T:+31348200100M:*****************W: Warranty ConditionsRaditeq B.V. offers a standard warranty term of three (3) years on their products, calculated from the shipping date, under the condition that the product is registered on . For registration of the product, the customer should provide the product model, serial number and the responsible reseller (if applicable). If the product is not registered, a limited warranty term of one (1) year will be applicable.Return Material Authorization (RMA) & Warranty repairIf a defect occurs to our product within the warranty term, a Return Material Authorization (RMA) ‘Warranty Repair’ request can be issued using the RMA link at /support. Upon receipt of the request, an RMA number will be provided. Please do not send the product without this RMA number! The defective product should be shipped to our service department at the following address:Raditeq B.V. – Service DepartmentVijzelmolenlaan 33447GX WOERDENThe NetherlandsThere will be no charge for repair services (materials or labour) within the (extended) warranty term.These warranty terms are not applicable to:• Normal wear and tear• Fibre optic cables• Products that have been improperly used• Products that have been used outside their specified range• Products that have been improperly installed and/or maintained• Products that have been modified without approval of Raditeq• Calibration and/or re-calibration of the productRepair services on products that are not covered by the Raditeq warranty will be charged to the customer.Repairs outside warrantyIf a defect is not covered under warranty, an RMA fixed-repair can be ordered on the RMA link: /support If a re-calibration is needed after repair, this calibration should be ordered separately. The calibration will be performed at the ISO17025 accredited calibration laboratories of DARE!! Calibrations, based on the applicable service code / prices. Warranty after repairFor repairs outside the original warranty period, a limited warranty of six months is applicable on the performed repair. Shipping conditions are the same as with repairs that are covered within the original warranty period.ShippingThe customer will need to arrange shipping and cover for the costs (like e.g. transportation costs, duties, taxes) for sending the defect product the service department of Raditeq in The Netherlands. Raditeq will arrange the courier and cover for the costs for the return shipment after repair.EU Declaration of Conformity WeRaditeq B.V.ofVijzelmolenlaan 3NL-3447GX WoerdenThe Netherlandsdeclare under our sole responsibility that theProduct: RadiPower® Seriesmodels: RPR3006Ware in accordance with the European directives:EMC Directive 2014/30/EULow Voltage Directive 2015/35/EURoHS Directive: 2015/863/EUper the provisions of the applicable requirements of the following harmonized standards: Emission: EN 61326-1:2013, Class A1Electrical equipment for measurement, control and laboratory use.Immunity:EN 61326-1:2013, Industrial level, performance criteria AElectrical equipment for measurement, control and laboratory use.Safety:EN 61010-1:2010, Safety requirements for electrical equipmentfor measurement, control, and laboratory useThe technical construction files are maintained at the adress specified above.Date of issue:16/08/21Place of issue:Woerden, The NetherlandsAuthorized by:P.W.J. DijkstraTitle of authority: DirectorRaditeq B.V. | Vijzelmolenlaan 3 | 3447GX Woerden | The Netherlands | T:+31 348 200 100。
第七章常见问题解答本章帮助您检查并解决在使用万全T/R350 3023服务器系统过程中可能遇到的问题。
如果您在使用过程中遇到未在手册中提及的新问题,请及时拨打800-810-8888免费咨询热线求助。
7.1 系统第一次启动1. 服务器第一次启动产生的问题通常是由于运输环境恶列导致硬件连接松脱或损坏部分硬件引起的。
如果出现问题,建议用户按以下步骤检查:2. 服务器的硬件配置是否与装箱单一致?3. 所有的电缆是否都连接正确并接牢?4. 处理器是否完全插入主板的插槽中?5. CPU散热片是否正常工作?6. 所有的PCI外插卡是否完全插入主板的插槽中并牢固?7. 为确保用户自己添加的插卡可以应用,应检查是否存在资源冲突,例如:两块外插卡是否共享同一中断?8. 所有的外部设备如光驱、软驱是否可以正常使用?9. 如果系统有一个硬盘,它是否已进行格式化或配置?10. 所有的设备驱动是否安装正确?11. 用户是否自己更改BIOS设置导致系统不能正常运行?12. 操作系统装入是否正确?可参阅操作系统相关文档。
13. 是否已按前面板上的系统电源按钮开启服务器(通电灯指示应该亮)?14. 系统电源线是否与系统正确连接并插入插座?15.如果这些项目都正确但问题仍然发生,参见后面的介绍或与代理商联系。
7.2 运行新的应用软件在运行一个新的应用软件时产生的问题通常与软件有关。
尤其是在其它软件运行正确的情况下,由设备硬件引起的故障可能性比较小。
如果出现问题,建议用户按以下步骤检查:1.系统是否满足软件对硬件的最低要求?请参阅软件的随机文件。
2.软件是否为合法软件?如果不是,换一个;未授权的复制软件经常运行不正常。
3.如果从一张软盘上运行软件,它是否是一个完好的拷贝?4.如果从光盘上运行软件,光盘是否有污损?5.如果从一个硬盘驱动器上运行软件,软件的安装是否正确?是否遵循所有的操作并安装了所有的文件?6.设备驱动程序安装是否正确?7.软件的配置是否正确?8.是否正确地使用软件?9.如果这些项目都正确但问题依然存在,请与软件商的客户服务代表联系。
第一章概要感谢惠购本公司的M350型罐体在线检测机。
M350罐体在线检测机是准确度高且信赖度高的金属罐内部在线检测系统。
应用高性能及高解析度的数字相机在生产线上检测罐体底部及罐体内壁落入的蚊子,苍蝇或其它异物,并通过将异常品剔除出去以保证生产线上罐体内的品质本设备还可以检测罐体内部喷涂不良。
保证罐内喷涂的品质。
本设备采用高强度LED照明,光源寿命长。
本设备操作简单,维护方便,亦能满足24小时工作的需求第二章系统组成1.系统组成1.分流系统:分流整理框架:用于把传送带上散乱的罐体分流整理为预定的队列,以便于下一步检测的执行2.触发传感器:对射式激光传感器:为视觉传感器拍照时的触发提供精确信号3.主控制箱:内部装有视觉传感器,控制器,照明光源,以及其它的辅助设施:用于拍照检测,并为不合格品的剔除提供触发信号.4.不合格品剔除系统:电磁控制阀,气嘴:用于不合格品的剔除2.关于各线缆网线电源线电源侧本体侧3.面板说明指示灯电源开关电源插口保险网线端口第三章安装1. 安装操作流程安装分流系统安装触发传感器安装剔除系统安装主控制箱连接线缆开启电源设定软件参数启动检测第四章设备参数及联机操作1.设备参数:控制箱外形尺寸:800*625*302; 电源:AC220V;解析度:640*480像素;传感器类型:CMOS;色彩模式:黑白;环境温度:0-50℃;周围湿度:20-80% (未结露);2.控制器说明:在控制器中有指示灯和按钮开关,它们的作用分别是:电源开关:控制目前检测机是否在开启状态。
指示灯准备:黄色亮时,告知检测机已经进入准备状态,时刻可以触发拍照。
检测:绿色亮时,说明经过检测,判断检测合格不良品剔除:红色亮时,说明经过检测,判断制品内部有异物,并进行剔除动作第五章 软件画面设定1.起始画面各项参数说明设置:用于获得模板画面,设定触发方式和完成自动曝光。
(详见软件设置面板)。
工具:用于设定模具保护器的各种监测条件,及数据连接(详见软件工具面板)。
Product DescriptionThe Cutler -Hammer ா AT3 Automatic Transfer Switch from Eaton’s electri-cal business is designed to provide unmatched performance, reliability and versatility for critical standby power applications. AT3 switches are equipped with the high-performance ATC-300 digital transfer controller for rock-solid monitoring, status reporting and transfer control operation. Superior design and robust construction make the AT3the industry benchmark for critical and distributed power systems.Electrical RatingsI Ratings 30 – 1000 amperes.I 2, 3 or 4-poles.I Up to 600 Vac, 50/60 Hz.I NEMA ா 1, 3R, 12, open.I Suitable for emergency and standby systems (all loads).I UL ா 1008 listed.ICSA ா C22.2 No. 178 certified.Industrial Design HighlightsI Double-throw, mechanicallyinterlocked transfer mechanism.I High withstand and closing ratings.ISeismic Zone 4 qualified (BOCA ா, CBC, IBC, UBC ா).Standard FeaturesIAuxiliary relay contacts:I Source 1 Present 2NO & 2NC I Source 2 Present 2NO & 2NC ISwitch position indication contacts:I Source 1 Position 1NO & 1NC I Source 2 Position 1NO & 1NCISource 1 & Source 2 sensing:I Undervoltage/under frequency I Overvoltage/over frequency I 3-phase rotation protectionI 3-phase voltage unbalance/loss I Pre-transfer signal contacts 1NO/1NC.I Go to Emergency (Source 2).I Seven field programmable time delays.ILCD-based display for program-ming, system diagnostic and Help message display.IMimic diagram with source available and connected LED indication.I Time-stamped history log.I System test pushbutton.IProgrammable plant exerciser —OFF , daily, 7, 14, 28-day interval selectable run time 0 – 600 min-utes no load/load with failsafe.ISafe manual operation under full load with permanently affixed operating handle.Optional FeaturesISuitable for Use as Service Equipment in the standard enclosure size.IAvailable TVSS surge suppres-sion for power/controller, engine start circuit, phone and cable connections.I Integrated distribution panels.IField-selectable multi-tap trans-former panel permits operation on a wide range of system voltages.I Integral overcurrent protection.I Space heater with thermostat.I Ammeter — load side.IStainless steel cover for controller.Service Entrance EquipmentThe AT3 transfer switch is available as rated as Suitable for Use as Service Equipment in the standard enclosure size. Cutler-Hammer Service Equip-ment rated transfer switches with integral overcurrent protection may be installed at the point of ServiceEntrance without the need for separate upstream disconnect devices and additional power connections.Eaton Electrical Inc.1000 Cherrington Parkway Moon Township, PA 15108United States tel: 1-800-525-2000©2005 Eaton Corporation All Rights Reserved Printed in USAPub. No. PA01602002E / Z2897April 2005CSA is a registered trademark of the Canadian Standards Association. Cutler -Hammer is a federally registered trademark of Eaton Corporation. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. UL is a federally registered trademark of Underwriters Laboratories Inc. BOCA is a registered trademark of Building Officials and Code Administrators International, Inc. Uniform BuildingCode (UBC) is a trademark of the International Conference of Building Officials (ICBO).Table 1. UL 1008 Withstand and Close-On Ratings (kA)ᕃ240 Vac.Switch Rating Amperes UL 1008 3-Cycle “Any Breaker” Rating Rating When Used With Upstream Fuse240 Vac 480 Vac 600 Vac Maximum Fuse Rating Fuse Type 600 Vac30 – 100 150150 – 225 225100100100100656565 ᕃ6525252525 200 400 400 400J, T J, T J, T J, T 200200200200 300 400 600100100100656565252525 400 6001200J, T J, T J, T 200200200 800100065 655050252516001600L L200200Table 2. Wall Mount Transfer Switch Standard Terminal Data for Power Cable ConnectionsNote: All terminals suitable for copper or aluminum conductors.Note: For alternate terminal sizes, contact Eaton.Switch Rating Amperes Breaker Frame Line Side (Normal and Standby Source)LoadConnection Neutral Connection 30 – 100 150 – 225 150 – 225 225 – 300HFD HFD HKD HKD (1) #14 – 1/0(1) #6 – 300(1) #3 – 350(1) #3 – 350(1) #14 – 1/0(1) #6 – 300(1) #6 – 360(1) #6 – 350(3) #14 – 1/0(3) #4 – 300(3) #4 – 350(3) #4 – 350 400 600 600HLD HLD HMDL (1) 4/0 – 600(2) 3/0 – 350(2) #1 – 500(2) #1 – 500(2) #1 – 500(2) #1 – 500(6) 250 – 350(6) 250 – 350(12) 4/0 – 500 600 (4-pole) 800 8001000NB HMDL HNB HNB(3) 3/0 – 400(3) 3/0 – 400(4) 4/0 – 500(4) 4/0 – 500(3) 3/0 – 400(3) 3/0 – 400(4) 4/0 – 500(4) 4/0 – 500(3) 3/0 – 400(12) 4/0 – 500(12) 4/0 – 500(12) 4/0 – 500Table 4. AT3 Transfer Switch Catalog Numbering SystemFD = 200 and 225 amperes, LD = 600 amperes, MD = 800 amperes for 240/120 Vac single-phase, 3-wire and 208Y/120 Vac 3-phase, 4-wire systems only.Table 3. Dimensions in Inches (mm) and Approximate Shipping in Lbs. (kg)ᕄ240/120 volt, single-phase, 3-wire or 208 volt, 3-phase, 4-wire systems only.ᕅWith multi-tap voltage selection panel.Switch TypeAmperesEnclosure Gutter Space Bolt PatternWeight Lbs. (kg)A (Height)B (Width)C (Depth)D (Width)E (Depth)G (Horizontal)H (Vertical)HFD ᕄHFD ᕄHFD ᕅ30 – 100150 – 225 30 – 10047.74 (1213.0)47.74 (1213.0)47.74 (1213.0)20.81 (528.6)20.81 (528.6)20.81 (528.6)17.22 (437.0)17.22 (437.0)17.22 (437.0)8.00 (203.2)8.00 (203.2)8.00 (203.2)4.00 (101.6)4.00 (101.6)4.00 (101.6)10.75 (273.0)10.75 (273.0)10.75 (273.0)46.44 (1180.0)46.44 (1180.0)46.44 (1180.0)232 (105)232 (105)240 (190)HFD ᕅHFD ᕄHKDHKD150150 – 225150 – 22530047.74 (1213.0)35.61 (904.0)48.00 (1219.2)56.00 (1422.4)20.81 (528.6)20.06 (509.5)20.81 (528.6)20.81 (528.6)17.22 (437.0)13.34 (339.0)18.40 (467.4)18.40 (467.4)8.00 (203.2)8.00 (203.2)8.00 (203.2)8.00 (203.2)4.00 (101.6)4.00 (101.6)4.00 (101.6)4.00 (101.6)10.75 (273.0)10.75 (273.0)11.00 (279.4)11.00 (279.4)46.44 (1180.0)34.31 (904.0)45.50 (1155.7)53.50 (1358.9)240 (190)150 (68)305 (138)295 (134)HLD HLD ᕄHMDL40060060053.00 (1346.0)64.00 (1625.6)76.74 (1949.2)25.81 (655.6)25.81 (655.6)25.81 (655.6)18.40 (467.4)18.40 (467.4)19.50 (495.3)8.00 (203.2)8.00 (203.2)8.00 (203.2)4.00 (101.6)4.00 (101.6)4.00 (101.6)16.00 (406.4)16.00 (406.4)16.00 (406.4)51.50 (1308.0)62.50 (1588.0)75.15 (1908.8)425 (193)475 (214)480 (218)HMDL ᕄHNB 800800 – 100076.74 (1949.2)76.74 (1949.2)25.81 (655.6)25.81 (655.6)19.50 (495.3)19.50 (495.3)8.00 (203.2)8.00 (203.2) 4.00 (101.6)4.00 (101.6)16.00 (406.4)16.00 (406.4)75.15 (1908.8)75.15 (1908.8)510 (232)540 (245)Typical (225 – 1000 A) Vertical Design Transfer Switch Equipment (Door Open and Deadfront Cover Removed)Power Panel NormalPower Source Molded Case Switch VoltageSelection Panel (Domestic)Emergency Power Source Molded Case SwitchMotorBrake BoardTransfer Mechanism Indicator Wheel Manual Operating Handle NeutralConnections Load Lugs (T op Entry)Service Disconnect。
TR300粗糙度形状测量仪 使用说明书时代集团北京时代之峰科技有限公司目录1 概述 (1)1.1测量原理 (1)1.2特点 (2)1.3标准配置 (2)1.4各部分名称 (3)1.5主要技术性能指标 (5)1.6按键功能介绍 (6)2安装与连接 (8)2.1传感器 (8)2.1.1导头的安装与拆卸 (8)2.1.2 测杆的拆卸 (8)2.1.3测杆护套的拆卸 (9)2.2主机 (9)2.2.1 传感器与主机的连接 (9)2.2.2 打印机与主机的连接 (10)2.2.3电脑与主机的连接 (11)3测量前的准备 (12)3.1总测量流程 (12)3.2测量前的水平调整 (13)3.3示值校准 (13)3.4测量方式选择 (14)3.4.1 无导头测量 (14)3.4.2 带导头测量 (15)4测量操作 (16)4.1开机过程 (16)4.2启动测量 (17)4.3设置、修改测量条件 (18)4.3.1粗糙度轮廓 (18)4.3.2波纹度轮廓 (20)4.3.3原始轮廓 (22)4.3.4 Rk轮廓 (23)4.3.5 功能选择 (24)4.3.6系统设置 (31)4.3.7 软件信息 (33)5数据通讯 (34)5.1RS232接口 (34)5.2USB接口 (34)6日常维护 (34)7常见故障排除 (34)8技术数据 (35)8.1传感器 (35)8.2驱动器 (35)8.3高度/倾斜调整 (35)8.4液晶显示器 (35)8.5电源 (35)8.6温度/湿度范围 (36)8.7外部尺寸和质量 (36)8.8可选件 (36)9参考信息 (37)9.1术语、参数定义 (37)9.1.1术语 (37)9.1.2几种滤波器的滑行长度 (38)9.1.3参数定义 (39)1 概述TR300便携式粗糙度形状测量仪是北京时代之峰科技有限公司推出的新产品,它是一台便携式触针表面粗糙度形状测量仪,适用于车间检定站、实验室、计量室等环境的检测。
© 3M 2009. All rights reserved.80-6016-0409-5 (0203.5)GP-2Important NoticeBefore utilizing any of 3M’s products, you should determine the suitability of the product for your intended use. You assume all risks and liability associated with such use. Warranty; Limited Remedy; Limited Liability.The 3M ™ TRP-303 Printer will be free from defects in material and manufacture for a period of one year from the date of purchase. Since print heads and cutters are consumable materials, these items are warranted for thirty (30) days from the date of purchase when used with compatible 3M products. All other 3M products will be free from defects in material and manufacture at the time of purchase, unless otherwise stated in the Product Literature. 3M MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE . If the products are defective within the warranty period stated above, 3M’s obligation and liability under this warranty are limited to repairing, replacing or refund of the purchase price, at 3M’s option, of any 3M’s products which, after normal and proper usage, are determined by 3M to be defective. This warranty does not extend to any 3M products which have been subjected to misuse, neglect accident or improper application, nor shall it extend to products which have been repaired or substantially altered outside of 3M’s manufacturing or repair facility. In no case shall 3M be liable for any indirect, special, incidental, or consequential damages based upon breach of warranty, breach of contract, negligence, strict liability or any other legal theory.3Electrical Markets Division6801 River Place Blvd.Austin, TX 78726-9000800 676 8381FAX 800 828 /electrical3M and Grafoplast are trademarks of 3M Company.Accessories and Supplies3M ™ Thermal Roll Printer TRP-303 accessory replacement parts are recommended to ensure the proper operation of the Thermal Roll Printer TRP-303. 3M ™ Thermal Roll Printer Black Ribbons are premium resintype that exhibit superior durability when compared to wax or resin-wax blend types. These ribbons have been chosen for their superior mark performance when used with heat shrink sleeves. All supplies and replacement parts for the 3M Thermal Roll Printer TRP-303 are listed below:UPC # (051128-)PC-RPL/TRP-3033M ™ Thermal Roll Printer Partial Cutter Replacement 58364FC-RPL/TRP-3033M ™ Thermal Roll Printer Full Cutter Replacement 58365PH-RPL/TRP-3033M ™ Thermal Roll Printer Thermal Print Head Replacement 58366PS-RPL/TRP-3033M ™ Thermal Roll Printer Power Supply Replacement 58367RBN-BLK-4/TRP-3033M ™ Thermal Roll Printer Black Ribbon 4 in. x 360 ft.58368RBN-BLK-2/TRP-3033M ™ Thermal Roll Printer Black Ribbon 2 in. x 360 ft.58369PR-RPL/TRP-3033M ™ Thermal Roll Printer Platten Roller Replacement 58384MS-RPL/TRP-3033M ™ Thermal Roll Printer Media Stand Replacement58385Ask about these additional identification systems from 3M.3M ™ ScotchCode ™ Tape Dispensers3M ™ ScotchCode ™ Write-On Dispensers3M ™ ScotchCode ™ Wire Marker Books 3M ™ Grafoplast ™ Si2K Identification System3M™ Thermal Roll Printer TRP-303Product BulletinHigh Qualityworkspaces. The Thermal Roll Printer TRP-303 can be(which can maintain the order of sequentialhas the same look and feel as WYSIWYG(“what you see is what you get”) programswith the capability to create bar codes andgraphics with alphanumeric characters.are standard.SpecificationsResolution 300 DPIPrint Speed Up to 4 ipsBench Space Requirements (L x W x H)22.5 in. x 8.1 in. x 8.9 in. / 571 mm x 206 mm x 226 mmOperating Temperature 41ºF to 104ºF (5ºC to 40ºC)Max. Print Width 4 in (101.6 mm)Ribbon Capacity110 meters, Max. 1.57 in. (40 mm) OD, 0.5 in. (12.7 mm) slotted coreInterface Internal Ethernet, USB 2.0, Centronics and RS-232CMedia Type Continuous heat shrink sleeveMedia Width & Thickness0.20 - 4.17 in. (5.0 - 106 mm) / 2.3 - 0.40 mil (0.06 – 1.0 mm)Memory Standard memory of 4 MB Flash, 8 MB SDRAM and a slot for a SD cardthat expands memory up to 4 GBRequired Operating Systems Windows® (95, 98, NT with Service Pack 6, 2000, XP)System Requirements Recommend at least 64 MB of RAM and 15 MB free hard-disk spaceProduct Number Description UPC # (051128-)TRP-303-PC-ES3M™ Thermal Roll Printer with Partial Cutter TRP-303-PC-ES58362TRP-303-FC-ES3M™ Thermal Roll Printer with Full Cutter TRP-303-FC-ES58363System Components• Printer Unit • Auto Switching Supply• CD with Labeling & Driver Software • USB Interface Cable• Quick Installation Guide • External Media Stand• Power Cord & Ribbon Take-Up Core • Full or Partial CutterWarranty period: The 3M TRP-303 Printer will be free from defects in material and manufacture for a period of one year from the date of purchase. Since print heads and cutters are consumable materials, these items are warranted for thirty (30) days from the date of purchase. See back page for full warranty statement. Printer head life: 16,404 yds. (15 km) of printed product, equivalent to more than 500,000 heat shrink marker sleeves of 1 inch in length.Key Features:• 3:1 shrink ratio• Minimum shrink temperature 100°C (212°F)• Meets the material requirements of SAE-AMS-DTL-23053 / 5• Marker permanence per SAE-AS81531 and MIL-STD-202 Method 215k when used with 3M Thermal Roll Printer Black Ribbon RBN-BLK series• Operating temperature -67ºF to +275ºF (-55ºC to +135ºC)• UL recognized and CSA certified at 125°C/66VProduct Number UPC # (051128-)Expanded ID(min.)Color Roll Length RecommendedUse ODNominal THHNWire SizeFP-303MS-1/8-WH-100583600.125” (3.18 mm)White100 feet (30.5 m)0.046”-0.106”(1.16 mm-2.70 mm)22 AWG - 16 AWGFP-303MS-3/16-WH-100583460.187” (4.75 mm)White100 feet (30.5 m)0.069”-0.159”(1.74 mm-4.04 mm)18 AWG - 12 AWGFP-303MS-1/4-WH-100583470.250” (6.36 mm)White100 feet (30.5 m)0.092”-0.213”(2.33 mm-5.40 mm)16 AWG - 10 AWGFP-303MS-3/8-WH-100583480.375” (9.53 mm)White100 feet (30.5 m)0.138”-0.319”(3.49 mm-8.10 mm)10 AWG - 6 AWGFP-303MS-1/2-WH-100583490.500” (12.70 mm)White100 feet (30.5 m)0.183”-0.425”(4.66 mm-10.80 mm)8 AWG - 2 AWGFP-303MS-3/4-WH-75583500.750” (19.05 mm)White75 feet (22.9 m)0.275”-0.638”(6.99 mm-16.19 mm)6 AWG - 3/0 AWGFP-303MS-1-WH-5058351 1.000” (25.40 mm)White50 feet (15.2 m)0.367”-0.850”(9.31 mm-21.59 mm)2 AWG - 350 MCMFP-303MS-1/8-YL-100583610.125” (3.18 mm)Yellow100 feet (30.5 m)0.046”-0.106”(1.16 mm-2.70 mm)22 AWG - 16 AWGFP-303MS-3/16-YL-100583530.187” (4.75 mm)Yellow100 feet (30.5 m)0.069”-0.159”(1.74 mm-4.04 mm)18 AWG - 12 AWGFP-303MS-1/4-YL-100583540.250” (6.36 mm)Yellow100 feet (30.5 m)0.092”-0.213”(2.33 mm-5.40 mm)16 AWG - 10 AWGFP-303MS-3/8-YL-100583550.375” (9.53 mm)Yellow100 feet (30.5 m)0.138”-0.319”(3.49 mm-8.10 mm)10 AWG - 6 AWGFP-303MS-1/2-YL-100583560.500” (12.70 mm)Yellow100 feet (30.5 m)0.183”-0.425”(4.66 mm-10.80 mm)8 AWG - 2 AWGFP-303MS-3/4-YL-75583570.750” (19.05 mm)Yellow75 feet (22.9 m)0.275”-0.638”(6.99 mm-16.19 mm)6 AWG - 3/0 AWGFP-303MS-1-YL-5058358 1.000” (25.40 mm)Yellow50 feet (15.2 m)0.367”-0.850”(9.31 mm-21.59 mm)2 AWG - 350 MCM。
一恒仪器创建于1997年,主要从事实验仪器、环境试验设备的研发、设计、制造、销售、服务为一体的高科技企业。
一恒公司已在全国各省市建立完善的渠道营销网络和售后服务分支机构,产品远销全球60多个国家和地区。
至2021年底,全球有六十万台一恒产品正在使用中。
我们一贯秉承“以科技保证品质,服务完善产品”的宗旨,领导行业潮流。
我们一直将品质和服务摆在首位,关键零部件采用进口产品,严格按照国家三包服务政策。
我们拥有完整、科学的质量管理体系,在2000年后陆续通过了ISO9001质量体系认证、ISO13485医疗器械行业质量体系认证和CE认证,部分产品获得美国UL认证,并获得“高新技术企业”认定。
一恒生产基地位于昆山市千灯镇,总占地面积3万多平方米。
2021年我们又在太仓浏河镇新建4万多平方米厂房,将于2022年正式投入使用。
届时,总年产能将达到十五万台产品,是世界众多跨国集团的ODM/OEM加工商。
我们将自己定位为“生命科学领域温湿度控制解决方案的专业供应商”。
一恒的售后服务网络覆盖上海、北京、广东、成都、沈阳、哈尔滨、厦门、昆明、郑州等地,我们本着以客户服务为导向,为客户提供实验室仪器及电子行业生产设备的整体解决方案和专业化服务,并以优质的售后服务广泛获得用户的好评。
制药工业包装测试药品和化妆品保存期测试工矿企业细胞生物学基础研究生物技术临床、大学、医院★ 样本上所有数据如有修改,不作另行通知,本公司具有最终解释权我们的品牌:定位:生命科学领域温湿度控制解决方案的专业供应商 经营理念:精英治企、持之一恒广告口号:我们只制造放心! (每小时卖出16台)价值观:满意客户、满意员工 、满意社会质量方针:提供客户期望的产品和服务生化培养箱 霉菌培养箱顺应世界环保潮流,进口品牌压缩机和循环风机,高效率、低能耗,不仅促进节能,而且使用寿命长,可将噪声降至更低限度,与传统低温设备相比,降温时间减少40%以上。
适用于环境保护、卫生防疫、药检、农畜、水产等科研、院校和生产部门。
请勿直视激光!请使用符合 DIN EN207和BGVB2标准的护目镜!运动时请不要将身体任何部分与激光头接触!切割后有余温可能会烫伤!激光头为精密产品请勿撞击!01.010202 0203.050405.10 0601. 产品概述1.1产品结构示意图温馨提示:使用前务必详细阅读本手册产品名称:复合焊接头产品型号:ND31产品特性:此焊接头具有焊接速度快、精度高等优势,在多点焊接时生产效率高。
激光头采用电机驱动X,Y轴振镜片,通过F-THETA聚焦镜组聚焦,具有多种摆动模式,可以显著提高焊接质量。
焊接头内部结构完全密封,可以避免光学部分受到灰尘污染。
配有气帘部件,减少焊接烟尘和飞溅残渣对镜片的污染。
可配各种带QBH接头激光器。
温馨提示:使用前务必详细阅读本手册1.2主要功能介绍1.2.1组件简介QBH组件与激光器光纤连接的核心连接器,提供行业标准的光纤接入口。
准直组件扩束器装配于激光头内,包含扩束器腔、扩束镜片组。
使光纤发出的光变为平行光。
水冷组件为QBH降温,防止烧坏光纤棒。
CCD组件将光信号转换为电信号,得到更清晰的焊接目标的图像。
反射组件把光纤光源反射到振镜上并且提供CCD组件 所需要的焊接状态实时光源。
场镜将改变方向的振镜光束转换成焦点在焊接材料上,实现高速精密的激光焊接。
振镜组件采用电机驱动X、Y轴振镜片,具有多种摆动模式,扩大焊缝的面积,允许工件有不规则焊缝、更大间隙。
风刀组件将反弹的焊渣吹走,为保护镜提供保护。
1.2.2设计与功能本激光头以光纤激光器为光源,在受控距离下在平面机床上对金属进行焊接。
本激光头焊接精准,耐用,便于维护而且易于调整。
所有媒介连接都内置于激光头内!1.2.3辅助媒介保护气体1. 为保护焊接处不氧化,使焊接处得到良好的保护,所使用的保护气体应具备不与焊接体发生有害的化学反应的化学特性。
2. 保护气质量必须符合ISO 8573-1:2010, Class 2.4.3标准,不可有杂质粒子、水、油。
第一章 产品简介
本章将简要介绍万全T/R3503013配置服务器的产品特色及技术特性以使您对万全T/R3503013配置服务器有一个概要的了解
1.1 产品概述
万全T/R3503013配置服务器是联想万全服务器系列产品中面向行业市场中等网络规模用户开发的一款部门级服务器产品
万全T/R3503013配置服务器支持基于P4核心设计的双路全新Intel Xeon处理器
L2Cache高达512K系统前端总线频率达400MHz为用户带来海量处理的全新体验万全T/R3503013配置服务器以处理能力可用性及可管理性等方面的强大优势
为电信ISP/ICP/ASP等行业用户提供了一款系统性能可用性最佳的部门级服务器精品万全T/R3503013配置服务器完全兼容Windows NT/2000 RedHat Linux Novell Netware等多种操作系统平台用户可以根据自己的需求在各种平台上构筑自己的网络及应用
万全T/R3503013配置服务器提供了塔式T3503013配置及机架式R3503013配置两种机型灵活满足不同用户环境下对部门级服务器的应用需求
1.2产品特色
万全T/R3503013配置服务器主板原理图如下
图1-1 万全T/R3503013配置服务器主板原理图
一出色的数据处理能力
1. 支持2颗0.13微米工艺制造的Intel Xeon Prestonia处理器该处理器基于P4内
核设计采用全新的Netburst架构可以支持2.0GHz或更高主频并支持超线程处理HyperThreading技术处理器二级缓存容量为512K带来了性能上的巨大飞跃采用双CPU时可使系统处理能力提升60%~80%保证满足用户业务扩充的需求
2. 系统前端总线频率为400MHz为处理器与系统之间的数据传输提供了通畅高速的数据
通道
3. 最大可支持16GB的 ECC Registered DDR200 SDRAM内存采用双路Interleave技术
设计的内存系统为内存与系统之间的数据传输提供了高达3.2GB/s的传输带宽使服务器在用户连接数增多时也能应付自如
4. 主板集成双通道Ultra 320 SCSI控制器 配合Ultra320 SCSI设备数据传输带宽高
达320MB/s
5. 支持6个64bit的PCI-X扩展槽分别连接在4个PCI-X段上系统I/O性能优秀
6. 主板集成双千兆网卡提供更大的网络带宽充分满足系统对网络请求的处理能力
二高可用性
1. 采用Registered ECC DDR200 SDRAM内存支持 4 Chipkill ECC内存纠错与回写技
术保证数据在内存与系统之间准确无误的传输处理
2. 大容量热插拔硬盘支持在线的系统存储容量迅速扩张同时可通过与RAID卡的配合
使用构成冗余磁盘阵列为服务器提供一个安全可靠高速的存储系统
3. 通过热插拔冗余电源的使用增强系统供电的可靠性
4. 集成的双千兆网卡在增强系统网络处理能力的同时提供了网络冗余路径加强了服
务器作为网络关键节点的可靠性
5. 作为选配部件的联想自主研发的万全慧眼管理模块为用户提供实时的硬件信息
保证系统的稳定性和高可用性
三优良的系统扩展性能
1. 系统提供6个PCI-X扩展槽涵盖66MHz100MHz133MHz三种带宽的PCI-X设备同
时也能支持普通PCI设备为用户提供了灵活的扩展空间
2. 对单CPU系统扩展方便直接插入第二颗CPU即可注意要求两颗CPU完全一样
3. 8个DIMM内存槽支持最大16GB的内存容量
4. 支持36G及更大容量SCSI容量热插拔硬盘最大容量为2个热插拔硬盘模组共10块硬
盘
5. 上述扩展能力使用户在业务量迅速增大时能够及时升级系统在相当长的时期内保护用
户的投资
四适合国内用户
提供详细的中文系统用户手册及操作系统安装导航光盘将方便国内用户配置使用维护这款万全T/R3503013配置服务器
尤其值得您注意的是随机附带的万全导航软件提供了操作系统自安装功能可以在万全服务器上对主流操作系统进行无人职守安装请您根据联想万全服务器导航软件用户手册说明选择是否使用该功能同时在本手册的第六章也为您提供了各种操作系统的详细安装步骤保证您在万全T/R3503013配置服务器上方便的进行操作系统安装
1.3产品技术特性
主机性能技术参数
i CPU Intel XEON 2.0~2.2GHz+ i Cache 512KB 二级缓存CPU 片内集成 i SMP 支持2个CPU
i 内存
8 x DIMM 最大支持16GB Registered ECC DDR 200内存
i IDE 控制器 Ultra ATA100 i SCSI 控制器 主板集成双通道Ultra320 SCSI 控制器
i 内部硬盘架 可支持2个热插拔硬盘模组提供10个热插拔硬盘接口支持Ultra320热插拔硬盘同时向下兼容Ultra160热插拔硬盘
i 显示 主板集成8MB 显存的ATI Rage-XL 显卡 i CD-ROM 48倍速IDE 光驱 i 软驱 1.44M 软驱
i 外驱动器架 3 5.25”CD-ROM 已占用一个
1
3.5”
1.44M 软驱占用
i 网卡
主板集成Intel 82546EB 双千兆网卡
i 键盘 PS/2接口键盘 i 鼠标 PS/2接口鼠标 扩展性能 i 扩展槽
1
PCI-X 133MHz 2PCI-X 100MHz 3
PCI-X 66MHz
i 内部设备接口 2个Ultra 320 SCSI 接口 2个IDE 口 1个软驱接口
i 外部设备接口 2个USB 串行口 1个9针串行口16550UART
1个25针并行口EPP/ECP
1个PS/2鼠标接口 / 1个PS/2键盘接口
1个显示器接口 2个RJ45网络接口
兼容操作系统
Microsoft Windows NT Server 4.0中英文版 Microsoft Windows 2000 Advanced Server 中英文版 Redhat Linux7.2 Redhat Linux7.3 Novell Netware 5.0
系统特性
i 工作环境温度
5°C~35°C
i 电源电压 220V 50Hz
i 电源功率 550W 单电源650W 2+1冗余电源 i 安全可靠 通过CCC 认证 T3503013配置430mm 220mm 665mm 高*宽*深 i 系统尺寸 R3503013配置
220mm
430mm 630mm
高*宽*深
随机软件
预装PC DOS7.0
联想万全服务器导航软件 联想网络管理软件
万全慧眼软件可选
注本文档所提供的信息如有变化恕不另行通知。