试验仪器自检自校规程
- 格式:doc
- 大小:1.34 MB
- 文档页数:87
实用标准文案 文档大全 吉黑高速公路北安至黑河段工程建设项目 试验仪器自检自校规程
北黑高速公路建设指挥部中心试验室 制 2010年4月28日 实用标准文案
文档大全 目 录
一 环刀校验方法 ············································································· 1 二 比重瓶校验方法 ·········································································· 3 三 液塑限联合测定仪校验方法 ··························································· 6 四 相对密度仪校验方法 ···································································· 8 五 击实仪校验方法 ·········································································· 10 六 灌砂法容重测定仪校验方法 ··························································· 12 七 称量盒(铝盒)校验方法 ······························································ 15 八 电热干燥箱校验方法 ···································································· 17 九 针片状规准仪校验方法 ································································· 19 十 压碎指标测定仪校验方法 ······························································ 22 十一 石料压碎值测定仪校验方法 ························································· 24 十二 水泥净浆搅拌机校验方法 ···························································· 26 十三 水泥稠度与凝结时间测定仪校验方法 ············································· 29 十四 水泥胶砂搅拌机校验方法 ··························································· 32 十五 水泥抗压夹具校验方法 ······························································ 35 十六 雷氏夹校验方法 ······································································· 37 十七 水泥标准筛校验方法 ································································· 41 十八 胶砂试验体成型振实台校验方法 ·················································· 43 十九 水泥沸煮箱校验方法 ································································· 46 二十 水泥胶砂流动度测定仪校验方法 ·················································· 48 二十一 水泥标准养护箱校验方法 ························································ 50 二十二 水泥试模校验方法 ································································· 52 二十三 混凝土、砂浆搅拌机校验方法 ·················································· 54 二十四 混凝土坍落度筒及捣捧校验方法 ··············································· 56 二十五 混凝土及砂浆试模验校验方法 ·················································· 58 二十六 气压式含量测定仪校验方法 ····················································· 60 二十七 集料试验筛校验方法 ······························································ 64 二十八 密度筒校验方法 ···································································· 71 二十九 容量瓶校验方法 ···································································· 73 三十 取芯机校验方法 ····································································· 76 三十一 脱模器校验方法 ···································································· 78 三十二 马歇尔试模校验方法 ······························································ 80 三十三 抽提仪校验方法 ···································································· 82 实用标准文案 文档大全 一 环刀校验方法
本方法适用于直径为58mm、62mm、64mm、70mm、79.8mm五种规格环刀的校验。 (一)概述 环刀是按GB/T50123-1999、SL237-1999、JTJ051-93进行粘土密度测定的专用器具。 (二)技术要求 2.1 外观检查无缺口、卷刃和明显变形。 2.2 剪切试样用环刀直径为64.0±0.4mm,高20±0.4mm。 2.3 压缩试样用环刀直径为79.8±0.5mm,高20±0.4mm。 2.4 膨胀试样用环刀直径为58.0±0.4mm,高25±0.4mm。 2.5 渗透试样用环刀直径为62.0±0.4mm,高40±0.4mm。 2.6 含水率、密度测定用环刀直径为70.0±0.4mm,高52±0.4mm。 (三)校验用标准器具 3.1 游标卡尺:最大量程150mm,分度值为0.02mm; 3.2 电子天平:称量200g,感量0.01g。 (四)环境条件 温度:20℃~24℃;相对湿度:≤75℅。 (五)校验方法 5.1 将环刀洗净、烘干、冷却后称其质量,准确至0.01g。 5.2 环刀直径用游标卡尺在环刀平面两个垂直方向上测量,取算术平均值。 5.3 环刀高度用游标卡尺在环刀平面每隔120°方向上测量高度一次,共测三次,取算术平均值。 (六)校验结果处理 校验结果符合技术要求为合格,合格者方可使用。 (七)校验周期 一年。 (八)附录 校验记录表格式。 实用标准文案
文档大全 环 刀 校 验 记 录 仪器管理编号: 校验编号: 出厂编号、型号: 校验日期: 年 月 日 仪器制造厂:_______________________ 环境条件:温度 ℃;相对湿度 %
计量器具名称 管理编号 最近检定日期 测量范围 分辨力 备注
环 刀 编 号
校 验 数 据
结 果 直径(mm) 高h(mm) 质量 (g) 体积
cm3 Φ1 Φ2 h1 h2 h3 h
结 论: 主管: 核验: 校验: 实用标准文案
文档大全 二 比重瓶校验方法 本方法适用于新的或使用中的比重瓶。 (一)概述 比重瓶用于粒径小于5mm的土及其他粉状物料比重(密度)测定。 (二)技术要求 2.1 外观:无裂纹或其它明显变形。 2.2 容积:经测量得出不同温度下的瓶水质量,准确至1mg,两次差值。0.02g (三)校验用标准工具 3.1 电子天平:称量1100g,感量0.01g。 3.1 温度计:刻度范围0~50℃,精确至1℃。 (四)环境条件 温度:20℃~24℃;相对湿度:≤75%。 (五)校验方法 5.1 外观:目测。 5.2 比重瓶计算校正法: 5.2.1 将比重瓶洗净、烘干,在干燥器内冷却称量m01,准确至0.01g,再次烘干冷却后称量m02。两次差值不大于0.02g,取其算术平均值m0。 5.2.2 将事先煮沸并冷却至室温的纯水注入比重瓶至满,塞上瓶塞,使多余的水沿瓶塞毛细管中溢出,擦干瓶外表面的水,称其瓶、水总质量m11,准确至0.01g,重复上述步骤,取其算术平均值m1,两次差值不得大于0.02g。 5.3 按公式计算m2:
m2= 式中:T1──比重瓶内纯水温度℃ T2──比重瓶内纯水任意温度℃ m1──温度为T1时的瓶水总质量 m2──温度为T2时的瓶水总质量 m0──比重瓶的质量 PW1──温度T1时水的密度 PW2──温度T2时水的密度 ωV──玻璃的膨胀系数,国产瓶可取2.4×10-5/℃ (六)校验结果处理 校验结果符合技术要求为合格,合格者方可使用。 (七)校验周期 一年。 (八)附录 校验记录表格式。