MOXA交换机设置指导
- 格式:ppt
- 大小:1.89 MB
- 文档页数:31


P/N: 1802005160016 *1802005160016*EDS-516A SeriesQuick Installation GuideMoxa EtherDevice™ SwitchVersion 7.1, March 2020Technical Support Contact Information/supportMoxa Americas:Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505 Moxa Europe:Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa Asia-Pacific:Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Moxa India:Tel: +91-80-4172-9088 Fax: +91-80-4132-10452020 Moxa Inc. All rights reserved.Package ChecklistMoxa EtherDevice™ Switch is shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance.• 1 Moxa EtherDevice Switch EDS-516A•RJ45 to DB9 Console port cable•Protective caps for unused ports•Panel mounting kit (optional—must order separately)•Quick installation guide (printed)•Warranty cardOptional Accessories•DR-4524: 45W/2A DIN-Rail 24 VDC Power Supply with 85 to 264 VAC input•DR-75-24: 75W/3.2A DIN-Rail 24 VDC Power Supply with 85 to 264 VAC input•DR-120-24: 120W/5A DIN-Rail 24 VDC Power Supply with 88 to 132 VAC/176 to 264 VAC input by switch•EDS-SNMP OPC Server Pro: CD with EDS-SNMP OPC Server Software and manual•WK-46: Wall Mounting Kit•RK-4U: 4U-high 19" rack mounting kitPanel Views of EDS-516A1.Grounding screw2.Console port3.Heat dissipation orifices4.6-pin terminal block for DI 1,DI 2, and PWR 25.6-pin terminal block for PWR1Relay 1, and Relay 26.10/100BaseT(X), ports 1 to 167.PWR 1: LED for power input 18.PWR 2: LED for power input 29.Fault LED10.MSTR/HEAD LED11.CPLR/TAIL LED12.TP port’s 100 Mbps LED13.TP port’s 10 Mbps LED14.Model Name15.Screw hole for Wall MountingKit16.DIN-Rail KitPanel Views of EDS-516A (SC/ST Type)NOTE: Array The appearance ofEDS-516A-MM-STis identical to EDS-516A-MM-SC.1.Grounding screw2.Console port3.Heat dissipation orifices4.6-pin terminal block for DI 1,DI 2, and PWR 25.6-pin terminal block for PWR1Relay 1, and Relay 26.10/100BaseT(X), ports 1 to 147.PWR 1: LED for power input 18.PWR 2: LED for power input 29.Fault LED10.MSTR/HEAD LED11.CPLR/TAIL LED12.TP port’s 100 Mbps LED13.TP port’s 10 Mbps LED14.Model Name15.100BaseFX Port 1516.100BaseFX Port 1617.100BaseFX LEDs18.Screw hole for Wall MountingKit19.DIN-Rail KitMounting DimensionsUnit = mm (inch)DIN-Rail MountingThe aluminum DIN-Rail attachment plate should already be fixed to the back panel of EDS-516A when you take it out of the box. If you need to reattach the DIN-Rail attachment plate to EDS-516A, make sure the stiff metal spring is situated towards the top, as shown by the following figures.STEP 1: Insert the top of the DIN-Rail into the slot just below the stiff metal spring. STEP 2: The DIN-Rail attachment unit will snap into place as shown in the following illustration.To remove the EDS-516A from the DIN-Rail, simply reverse Steps 1 and 2 above.Wall Mounting (Optional)For some applications, you will find it convenient to mount MoxaEDS-516A on the wall, as shown by the following illustrations:STEP 1: Remove thealuminum DIN-Railattachment plate from theMoxa EDS-516A rearpanel, and then attach thewall mount plates with M3screws, as shown by thefigure on the right.STEP 2: Mounting Moxa EDS-516A on the wall requires4 screws. Use the EDS-516A, with wall mount platesattached, as a guide to mark the correct locations ofthe 4 screws. The heads of the screws should be lessthan 6.0 mm in diameter, and the shafts should be lessthan 3.5 mm in diameter, as shown by the figure on theright.NOTE Before tightening the screws into the wall, make sure the screw head and shank size are suitable by inserting the screw throughone of the keyhole-shaped apertures of the Wall Mounting Plates. Do not screw the screws in all the way—leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws.STEP 3: Once the screws are fixed to the wall, insert the four screw heads through the wide parts of the keyhole-shaped apertures, and then slide the EDS-516A downwards, as indicated in the figure at the right. Tighten the four screws for more stability.ATEX Information1. Certification number DEMKO 09 ATEX 0812123X2. Ambient range: -40°C ≤ Tamb ≤ 75°C3. Certification string: (Ex nA nC IIC T4 Gc4.Standards covered:EN60079-0:2012+A11:2013, EN 60079-15:2010 5. The conditions of safe usage:• The Ethernet Communication Devices are to be mounted in anIP54 enclosure and used in an area of not more than pollution degree 2 as defined by IEC60664-1.• A 4 mm 2 conductor must be used when connection to theexternal grounding screw is utilized.• Conductors suitable for use in an ambient temperature of 93°Cmust be used for the Power Supply Terminal.• Provisions shall be made, either in external to the apparatus, toprevent the rated voltage being exceeded by the transients disturbances of more than 40%.Wiring RequirementsYou should also pay attention to the following points:•Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection pointNOTE: Do not run signal or communications wiring and power wiring through the same wire conduit. To avoid interference, wires withdifferent signal characteristics should be routed separately•You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can bebundled together•Separate input wiring and output wiring•We advise that you label wiring to all devices in the system when necessary.Grounding the Moxa EDS-516AGrounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.Wiring the Relay ContactEDS-516A has two sets of relay outputs—relay 1 and relay 2. Each Relay Contact consists of the two contacts of the terminal block on EDS-516A’s top panel. You can refer to the next section for detailed instructions on how to connect the wires to the terminal block connector, and how to attach the terminal block connector to the terminal block receptor. In this section, we will explain the meaning of the two contacts used to connect the Relay Contact.FAULT:The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-configured events. The two wires attached to the fault contacts form an open circuit when a user-configured event is triggered. If auser-configured event does not occur, the fault circuit remains closed.Wiring the Redundant Power InputsEDS-516A has two sets of power inputs—power input 1 and power input 2.The top two contacts and the bottom two contacts of the 6-pin terminal block connector on EDS’ top panel are used for EDS’ two digital inputs. The top and front views of one of the terminal block connectors are shown here.STEP 1: Insert thenegative/positive DC wires into the V-/V+ terminals, respectively. STEP 2: To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector. STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on the EDS-516A’s top panel.Wiring the Digital InputsEDS-516A has two sets of digital inputs, DI 1 and DI 2. Each DI consists of two contacts of the 6-pin terminal block connector on EDS’s top panel, which are used for EDS’s two DC inputs. The top and front views of one of the terminal block connectors are shown here.STEP 1: Insert the negative Array (ground)/positive DI wires into the┴/I1 terminals, respectively.STEP 2: To keep the DI wires frompulling loose, use a smallflat-blade screwdriver to tightenthe wire-clamp screws on the frontof the terminal block connector.STEP 3: Insert the plastic terminalblock connector prongs into theterminal block receptor, which islocated on the EDS-516A’s toppanel.Communication ConnectionsAll models of EDS-516A have one RJ45 console port (RS-232 interface), between 14 and 16 10/100BaseTX Ethernet ports. Some models also have 2 100BaseFX (SC/ST-type connector) fiber ports.In this section, we present two types of diagrams—Pinout Diagrams and Cable Wiring Diagrams—to convey information about the ports and the cables used to connect Moxa EDS-516A to other devices: Pinouts—The meaning of the “Pinouts” diagrams is straightforward. The diagrams simply display the type of signal passing through each of the port’s pins.Cable Wiring—Diagrams labeled “Cable Wiring” present standard cable wiring schemes for cables used to connect Moxa EtherDevice Switch’s ports to other devices. These diagrams display three pieces of information:1.When building your own cable, refer to the “pin-to-pin” CableWiring information displayed between the two vertical dashed lines to see which pin of the connector on the left should be connected to which pin of the connector on the right.2.The information to the left of the left vertical dashed lines gives thepinouts of the relevant Moxa EtherDevice Switch port.3.The information to the right of the right vertical dashed line gives thepinouts of the opposing device’s port.NOTE 1. The pin numbers for male DB9 and DB25 connectors, and hole numbers for female DB9 and DB25 connectors arelabeled on the connector. However, the numbers aretypically quite small, so you may need to use a magnifyingglass to see the numbers clearly.2. The pin numbers for both 8-pin and 10-pin RJ45 connectors(and ports) are typically not labeled on the connector (orport). Refer to the following Pinout and Cable Wiringdiagrams to see how RJ45 pins are numbered.RS-232 ConnectionMoxa EDS-516A has one RS-232 (10-pin RJ45) console port, located on the top panel. Use either an RJ45-to-DB9 or RJ45-to-DB25 cable (see the cable following wiring diagrams) to connect Moxa EDS-516A’s console port to your PC’s COM port. You may then use a console terminal program, such as Moxa PComm Terminal Emulator, to access Moxa EDS-516A’s console configuration utility.RJ45 (10-pin) Console Port Pinouts PinDescription 1– 2DSR 3RTS 4– 5TxD 6RxD 7GND 8CTS 9DTR 10 –RJ45 (10-pin) to DB9 (F) Cable WiringRJ45 (10-pin) to DB25 (F) Cable Wiring10/100BaseT(X) Ethernet Port ConnectionThe 10/100BaseT(X) ports located on Moxa EtherDevice Switch’s front panel are used to connect to Ethernet-enabled devices. Most users will choose to configure these ports for Auto MDI/MDI-X mode, in which case the port’s pinouts are adjusted automatically depending on the type of Ethernet cable used (straight-through or cross-over), and the type of device (NIC-type or HUB/Switch-type) connected to the port.In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-type) ports. We also give cable wiring diagrams for straight-through and cross-over Ethernet cables.10/100Base T(x) RJ45 Pinouts MDI Port Pinouts MDI-X Port Pinouts 8-pin RJ45 PinSignal1 Tx+2 Tx-3 Rx+6 Rx- Pin Signal 1 Rx+ 2 Rx- 3 Tx+ 6 Tx-RJ45 (8-pin) to RJ45 (8-pin) Straight-through Cable WiringRJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring100BaseFx Ethernet Port ConnectionThe concept behind the SC/ST port and cable is quite straightforward. Suppose you are connecting devices I and II. As opposed to electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used transmit data from device II to device I, for full-duplex transmission.All you need to remember is to connect the Tx (transmit) port of device I to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II. If you are making your own cable, we suggest labeling the two sides of the same line with the same letter (A-to-A and B-to-B, as shown by the following illustration, or A1-to-A2 and B1-to-B2).SC-Port Pinouts SC-Port to SC-Port Cable WiringST-Port Pinouts ST-Port to ST-Port Cable WiringLED IndicatorsThe front panel of Moxa EDS-516A contains several LED indicators. The function of each LED is described in the following table:LED Color State DescriptionPWR1 AMBER OnPower is being supplied to powerinput P1.OffPower is not being supplied to powerinput P1.PWR2 AMBER OnPower is being supplied to powerinput P2.OffPower is not being supplied to powerinput P2.FAULT RED OnWhen the corresponding PORT alarmis enabled, and a user-configuredevent is triggered.OffWhen the corresponding PORT alarmis enabled and a user-configuredevent is not triggered, or when thecorresponding PORT alarm isdisabled.MSTR/HEAD GREENOnWhen the EDS-516A is set as theMaster of the Turbo Ring, or as theHead of the Turbo Chain.BlinkingThe EDS-516A has become the RingMaster of the Turbo Ring, or the Headof the Turbo Chain, after the TurboRing or the Turbo Chain is down.OffWhen the EDS-516A is not the Masterof this Turbo Ring or is set as theMember of the Turbo Chain.CPLR/TAIL GREENOnWhen the EDS-516A coupling functionis enabled to form a back-up path, orwhen it's set as the Tail of the TurboChain.Blinking When the Turbo Chain is down.OffWhen the EDS-516A disables thecoupling function.10M(TP) GREENOn TP port’s 10 Mbps link is active. Blinking Data is being transmitted at 10 Mbps. Off TP port’s 10 Mbps link is inactive.100M(TP) GREENOn TP port’s 100 Mbps link is active. BlinkingData is being transmitted at 100Mbps.Off TP port’s 100 Mbps link is inactive.SpecificationsTechnologyStandards IEEE 802.3 for 10BaseT,IEEE 802.3u for 100BaseT(X) and 100Base FX,IEEE 802.3x for Flow Control,IEEE 802.1D for Spanning Tree Protocol,IEEE 802.1w for Rapid STP,IEEE 802.1Q for VLAN Tagging,IEEE 802.1p for Class of Service,IEEE 802.1X for Authentication,IEEE 802.3ad for Port Trunk with LACP Protocols IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3,DHCP Server/Client, DHCP Option 66/67/82,BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP,HTTPS, Telnet, SSH, Syslog, IPv6, LLDP, IEEE1588 PTP, Modbus/TCP, SNMP InformMIB MIB-II, Ethernet-like MIB, P-BRIDGE MIB,Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMONMIB Group 1,2,3,9InterfaceRJ45 Ports 10/100BaseT(X) auto negotiation speed, F/Hduplex mode, and auto MDI/MDI-X connection Fiber Ports optional 100BaseFX (SC/ST connector) Console Port RS-232 (10-pin RJ45)LED Indicators PWR1, PWR2, FAULT, 10/100M (TP port),MSTR/HEAD and CPLR/TAILAlarm Contact Two relay outputs with current carrying capacityof 1A @ 24 VDCDigital Input Two inputs with the same ground, butelectrically isolated from the electronics• For state “1”: +13 to +30V• For state “0”: -30 to +3V• Max. input current: 8 mAPowerInput Voltage 24 VDC (12 to 45 VDC), redundant inputs Input Current (@24V) 0.44A: (EDS-516A)0.51A: (EDS-516A-MM-SC/ST)Connection Two removable 6-pin terminal blocksPresentOverload CurrentProtectionPresentReverse PolarityProtectionMechanicalCasing IP30 protection, metal caseDimensions 95 × 135 × 140 mm (W × H × D)Weight 1.586 kgInstallation DIN-Rail, Wall Mounting (optional kit) EnvironmentOperating Temperature 0 to 60°C (32 to 140°F)-40 to 75°C (-40 to 167°F) for -T models Storage Temperature -40 to 85°C (-40 to 185°F)Ambient Relative5% to 95% (non-condensing)HumidityRegulatory ApprovalsSafety UL 508, UL 60950-1CSA C22.2 No. 60950-1, EN 60950-1 Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C, andD, ATEX Zone 2, Ex nA nC IIC T4 GcEMI FCC Part 15, CISPR (EN 55022) class AEMS EN 61000-4-2 (ESD), Level 2EN 61000-4-3 (RS), Level 3EN 61000-4-4 (EFT), Level 2EN 61000-4-5 (Surge), Level 3EN 61000-4-6 (CS), Level 3EN 61000-4-8EN 61000-4-11EN 61000-4-12Shock IEC 60068-2-27Freefall IEC 60068-2-32Vibration IEC 60068-2-6WARRANTY 5 years。
ICS-G7848A Series48G Layer3full Gigabit modular managed EthernetswitchesFeatures and Benefits•Up to48Gigabit Ethernet ports•Up to48optical fiber connections(SFP slots)•Up to48PoE+ports with external power supply(with IM-G7000A-4PoEmodule)•Fanless,-10to60°C operating temperature range•Modular design for maximum flexibility and hassle-free future expansion•Hot-swappable interface and power modules for continuous operation•Turbo Ring and Turbo Chain(recovery time<20ms@250switches),andSTP/RSTP/MSTP for network redundancy•Isolated redundant power inputs with universal110/220VAC power supplyrange•Supports MXstudio for easy,visualized industrial network management•V-ON™ensures millisecond-level multicast data and video network recoveryCertificationsIntroductionProcess automation and transportation automation applications combine data,voice,and video,and consequently require high performance and high reliability.The ICS-G7848A Series full Gigabit backbone switches’modular design makes network planning easy,and allows greater flexibility by letting you install up to48Gigabit Ethernet ports.The ICS-G7848A Series also supports Layer3routing functionality to facilitate the deployment of applications across networks,making them ideal for large-scale industrial networks.The ICS-G7848A’s full Gigabit capability increases bandwidth to provide high performance and the ability to quickly transfer large amounts of video,voice,and data across a network.The fanless switches support the Turbo Ring,Turbo Chain,and RSTP/STP redundancy technologies,and come with an isolated redundant power supply to increase system reliability and the availability of your network backbone.Additional Features and Benefits•Layer3switching functionality to move data and information across networks(ICS-G7800A Series)•Advanced PoE management functions:PoE output setting,PD failure check,PoE scheduling,and PoE diagnostics(with IM-G7000A-4PoE module)•Command line interface(CLI)for quickly configuring major managed functions•Supports advanced VLAN capability with Q-in-Q tagging•DHCP Option82for IP address assignment with different policies •Supports EtherNet/IP and Modbus TCP protocols for device management and monitoring•Compatible with PROFINET protocol for transparent data transmission•Digital inputs for integrating sensors and alarms with IP networks •Redundant,dual AC power inputs•IGMP snooping and GMRP for filtering multicast traffic •IEEE802.1Q VLAN and GVRP protocol to ease network planning •QoS(IEEE802.1p/1Q and TOS/DiffServ)to increase determinism •Port Trunking for optimum bandwidth utilization•TACACS+,SNMPv3,IEEE802.1X,HTTPS,and SSH to enhance network security•Access control lists(ACL)increase the flexibility and security of network management•SNMPv1/v2c/v3for different levels of network management •RMON for proactive and efficient network monitoring •Bandwidth management to prevent unpredictable network status •Lock port function for blocking unauthorized access based on MAC address•Port mirroring for online debugging•Automatic warning by exception through email and relay outputSpecificationsInput/Output InterfaceAlarm Contact Channels Relay output with current carrying capacity of2A@30VDCDigital Inputs+13to+30V for state1-30to+1V for state0Max.input current:8mAEthernet InterfaceStandards IEEE802.1D-2004for Spanning Tree ProtocolIEEE802.1p for Class of ServiceIEEE802.1Q for VLAN TaggingIEEE802.1s for Multiple Spanning Tree ProtocolIEEE802.1w for Rapid Spanning Tree ProtocolIEEE802.1X for authenticationIEEE802.3for10BaseTIEEE802.3ab for1000BaseT(X)IEEE802.3ad for Port Trunk with LACPIEEE802.3u for100BaseT(X)and100BaseFXIEEE802.3x for flow controlIEEE802.3z for1000BaseSX/LX/LHX/ZXIEEE802.3af/at for PoE/PoE+outputSlot Combination12slots for4-port interface modules(10/100/1000BaseT(X),or PoE+10/100/1000BaseT(X),or100/1000BaseSFP slots)1Ethernet Software FeaturesManagement ARP,Back Pressure Flow Control,BOOTP,DDM,DHCP Option66/67/82,DHCP Server/Client,IPv4,LLDP,Port Mirror,RMON,SNMP Inform,SNMPv1/v2c/v3,Syslog,Telnet,TFTP,SMTP,RARP,Flow controlFilter802.1Q,GMRP,GVRP,IGMP v1/v2/v3,QinQ VLANMulticast Routing DVMRP,PIM-DM,PIM-SM,PIM-SSMRedundancy Protocols Link Aggregation,MSTP,RSTP,Turbo Chain,Turbo Ring v1/v2,V-ONRouting Redundancy VRRPSecurity Access control list,Broadcast storm protection,HTTPS/SSL,MAB authentication,Sticky MAC,NTP authentication,Port Lock,RADIUS,SSH,TACACS+Time Management NTP Server/Client,SNTPUnicast Routing OSPF,RIPV1/V2,Static RouteIndustrial Protocols EtherNet/IP,Modbus TCPMIB Bridge MIB,Ethernet-like MIB,MIB-II,P-BRIDGE MIB,Q-BRIDGE MIB,RMON MIBGroups1,2,3,9,RSTP MIBSwitch PropertiesDRAM128MBFlash16MBIGMP Groups4096Jumbo Frame Size9.6KBMAC Table Size16KMax.No.of VLANs2561.See the IM-G7000A datasheet for Gigabit Ethernet module product information.Packet Buffer Size12MbitsVLAN ID Range VID1to4094Priority Queues8USB InterfaceStorage Port USB Type ASerial InterfaceConsole Port USB-serial console(Type B connector) Power ParametersInput Voltage110to220VAC,Redundant dual inputs Operating Voltage85to264VACOverload Current Protection SupportedReverse Polarity Protection SupportedInput Current0.87/0.51A@110/220VACPhysical CharacteristicsIP Rating IP30Dimensions440x176x523.8mm(17.32x6.93x20.62in) Weight12,900g(28.5lb)Installation Rack mountingEnvironmental LimitsOperating Temperature-10to60°C(14to140°F)Storage Temperature(package included)-40to85°C(-40to185°F)Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsSafety EN60950-1,UL60950-1EMC EN55032/24EMI CISPR32,FCC Part15B Class AEMS IEC61000-4-2ESD:Contact:6kV;Air:8kVIEC61000-4-3RS:80MHz to1GHz:20V/mIEC61000-4-4EFT:Power:4kV;Signal:4kVIEC61000-4-5Surge:Power:2kV;Signal:2kVIEC61000-4-6CS:10VIEC61000-4-8PFMFRailway EN50121-4Freefall IEC60068-2-32Shock IEC60068-2-27Vibration IEC60068-2-6MTBFTime314,973hrsStandards Telcordia(Bellcore),GBWarrantyWarranty Period5yearsDetails See /warrantyPackage ContentsDevice1x ICS-G7848A Series switchCable1x USB type A male to USB type B maleInstallation Kit2x rack-mounting ear4x cap,plastic,for SFP slotPower Supply1x power cord,EU type1x power cord,US typeDocumentation1x quick installation guide1x warranty cardNote48V external power supply,SFP modules and/or modules from the IM-G7000A ModuleSeries need to be purchased separately for use with this product.DimensionsOrdering InformationModel Name Layer10GbE SFP+Slots 100/1000Base SFPSlots10/100/1000BaseT(X)PortsRJ45ConnectorOperating Temp.ICS-G7848A-HV-HV30Up to48Up to48-10to60°CAccessories(sold separately)IM-G7000A Module SeriesIM-G7000A-4GSFP Gigabit Ethernet interface module with4100/1000BaseSFP slots,-10to60°C operating temperature IM-G7000A-4GTX Gigabit Ethernet interface module with410/100/1000BaseT(X)ports,-10to60°C operatingtemperatureIM-G7000A-4PoE Gigabit Ethernet PoE+interface module with410/100/1000BaseT(X)ports,-10to60°C operatingtemperaturePower ModulesPWR-G7000A-AC Power supply module(85to264VAC)for ICS-G7748A/G7750A/G7752A/G7848A/G7850A/G7852ASeries,-10to60°C operating temperatureSFP ModulesSFP-1FELLC-T SFP module with1100Base single-mode with LC connector for80km transmission,-40to85°Coperating temperatureSFP-1FEMLC-T SFP module with1100Base multi-mode,LC connector for2/4km transmission,-40to85°C operatingtemperatureSFP-1FESLC-T SFP module with1100Base single-mode with LC connector for40km transmission,-40to85°Coperating temperatureSFP-1G10ALC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for10km transmission;TX1310nm,RX1550nm,0to60°C operating temperatureSFP-1G10ALC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for10km transmission;TX1310nm,RX1550nm,-40to85°C operating temperatureSFP-1G10BLC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for10km transmission;TX1550nm,RX1310nm,0to60°C operating temperatureSFP-1G10BLC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for10km transmission;TX1550nm,RX1310nm,-40to85°C operating temperatureSFP-1G20ALC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for20km transmission;TX1310nm,RX1550nm,0to60°C operating temperatureSFP-1G20ALC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for20km transmission;TX1310nm,RX1550nm,-40to85°C operating temperatureSFP-1G20BLC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for20km transmission;TX1550nm,RX1310nm,0to60°C operating temperatureSFP-1G20BLC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for20km transmission;TX1550nm,RX1310nm,-40to85°C operating temperatureSFP-1G40ALC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for40km transmission;TX1310nm,RX1550nm,0to60°C operating temperatureSFP-1G40ALC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for40km transmission;TX1310nm,RX1550nm,-40to85°C operating temperatureSFP-1G40BLC WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for40km transmission;TX1550nm,RX1310nm,0to60°C operating temperatureSFP-1G40BLC-T WDM-type(BiDi)SFP module with11000BaseSFP port with LC connector for40km transmission;TX1550nm,RX1310nm,-40to85°C operating temperatureSFP-1GEZXLC SFP module with11000BaseEZX port with LC connector for110km transmission,0to60°C operatingtemperatureSFP-1GEZXLC-120SFP module with11000BaseEZX port with LC connector for120km transmission,0to60°C operatingtemperatureSFP-1GLHLC SFP module with11000BaseLH port with LC connector for30km transmission,0to60°C operatingtemperatureSFP-1GLHLC-T SFP module with11000BaseLH port with LC connector for30km transmission,-40to85°C operatingtemperatureSFP-1GLHXLC SFP module with11000BaseLHX port with LC connector for40km transmission,0to60°C operatingtemperatureSFP-1GLHXLC-T SFP module with11000BaseLHX port with LC connector for40km transmission,-40to85°Coperating temperatureSFP-1GLSXLC SFP module with11000BaseLSX port with LC connector for1km/2km transmission,0to60°Coperating temperatureSFP-1GLSXLC-T SFP module with11000BaseLSX port with LC connector for1km/2km transmission,-40to85°Coperating temperatureSFP-1GLXLC SFP module with11000BaseLX port with LC connector for10km transmission,0to60°C operatingtemperatureSFP-1GLXLC-T SFP module with11000BaseLX port with LC connector for10km transmission,-40to85°C operatingtemperatureSFP-1GSXLC SFP module with11000BaseSX port with LC connector for300m/550m transmission,0to60°Coperating temperatureSFP-1GSXLC-T SFP module with11000BaseSX port with LC connector for300m/550m transmission,-40to85°Coperating temperatureSFP-1GZXLC SFP module with11000BaseZX port with LC connector for80km transmission,0to60°C operatingtemperatureSFP-1GZXLC-T SFP module with11000BaseZX port with LC connector for80km transmission,-40to85°C operatingtemperaturePower CordsPWC-C7EU-2B-183Power cord with Continental Europe(EU)plug,2.5A/250V,1.83mPWC-C13US-3B-183Power cord with United States(US)plug,1.83mPWC-C13EU-3B-183Power cord with Continental Europe(EU)plug,1.83mPWC-C13UK-3B-183Power cord with United Kingdom(UK)plug,1.83mPWC-C13CN-3B-183Power cord with three-prong China(CN)plug,1.83mPWC-C7US-2B-183Power cord with United States(US)plug,10A/125V,1.83mPWC-C7AU-2B-183Power cord with Australian(AU)plug,2.5A/250V,1.83mPWC-C13AU-3B-183Power cord with Australian(AU)plug,1.83mPWC-C7UK-2B-183Power cord with United Kingdom(UK)plug,2.5A/250V,1.83mSoftwareMXview-50Industrial network management software with a license for50nodes(by IP address)MXview-100Industrial network management software with a license for100nodes(by IP address)MXview-250Industrial network management software with a license for250nodes(by IP address)MXview-500Industrial network management software with a license for500nodes(by IP address)MXview-1000Industrial network management software with a license for1000nodes(by IP address)MXview-2000Industrial network management software with a license for2000nodes(by IP address)MXview Upgrade-50License expansion of MXview industrial network management software by50nodes(by IP address) Storage KitsABC-02-USB Configuration backup and restoration tool,firmware upgrade,and log file storage tool for managedEthernet switches and routers,0to60°C operating temperatureABC-02-USB-T Configuration backup and restoration tool,firmware upgrade,and log file storage tool for managedEthernet switches and routers,-40to75°C operating temperature©Moxa Inc.All rights reserved.Updated Jun21,2021.This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc.Product specifications subject to change without notice.Visit our website for the most up-to-date product information.。
摩莎交换机EDS-405A与电脑连接查看配置及修改方法
2015-7-20 已论证
第一步:用一条RJ45普通网线,将交换机与电脑连接,交换机端1#,2#,3#网口的任何一个都可以。
第二步:将自己的电脑IP地址配置成:192.168.127.XXX,与交换机在同一网段,如配置成:192.168.127.254
(交换机地址:192.168.127.253 )。
子网掩码:255.255.255.0
第三步:打开IE浏览器,输入交换机地址:192.168.127.253 ,回车后即可进入交换机设置菜单,查看及修改可参照
408A使用手册
注:在修改配置时,应将交换机的DIP开关1234全部拨到OFF位置,否则,修改不了呀。
第四步:已验证2016-3-31
出现菜单后→点击菜单“Communication Redundancy”→在选择框Redundancy Protocol中选择“Turbo Ring V2”协议,将ABB DCS 的环网上的5个节点的摩莎交换机
全部设置成urbo Ring V2协议;其中只将LCS1站的摩莎交换机设置中的“Set as Master”(设置主站)复选框打√→按下“Activate”(保存)按钮。
这样所有换网交换机所用的协议全部就是urbo Ring V2协议了。
其它的参数都不要动即可。