高强砼回弹仪换算表
- 格式:doc
- 大小:162.50 KB
- 文档页数:17
附录A 测区混凝土强度换算值
平均
回弹值 测区混凝土
强度换算值(MPa) 平均
回弹值 测区混凝土
强度换算值(MPa)
Rm ƒccu,h,i Rm ƒccu,h,i
34.9 60.1 36.3 62.0
35.0 60.2 36.4 62.1
35.1 60.3 36.5 62.2
35.2 60.5 36.6 62.4
35.3 60.6 36.7 62.5
35.4 60.7 36.8 62.6
35.5 60.9 36.9 62.8
35.6 61.0 37.0 62.9
35.7 61.1 37.1 63.0
35.8 61.3 37.2 63.2
35.9 61.4 37.3 63.3
36.0 61.6 37.4 63.4
36.1 61.7 37.5 63.6
36.2 61.8 37.6 63.7
平均 测区混凝土 平均 测区混凝土 2 回弹值 强度换算值(MPa) 回弹值 强度换算值(MPa)
Rm ƒccu,h,i Rm ƒccu,h,i
37.7 63.9 39.3 66.0
37.8 64.0 39.4 66.2
37.9 64.1 39.5 66.3
38.0 64.3 39.6 66.4
38.1 64.4 39.7 66.6
38.2 64.5 39.8 66.7
38.3 64.7 39.9 66.8
38.4 64.8 40.0 67.0
38.5 64.9 40.1 67.1
38.6 65.1 40.2 67.2
38.7 65.2 40.3 67.4
38.8 65.3 40.4 67.5
38.9 65.4 40.5 67.6
39.0 65.6 40.6 67.8
39.1 65.8 40.7 67.9
39.2 65.9 40.8 68.0
平均 测区混凝土 平均 测区混凝土 3 回弹值 强度换算值(MPa) 回弹值 强度换算值(MPa)
Rm ƒccu,h,i Rm ƒccu,h,i
40.9 68.2 42.5 70.3
41.0 68.3 42.6 70.4
41.1 68.4 42.7 70.5
41.2 68.6 42.8 70.7
41.3 68.7 42.9 70.8
41.4 68.8 43.0 70.9
41.5 69.0 43.1 71.1
41.6 69.1 43.2 71.2
41.7 69.2 43.3 71.3
41.8 69.3 43.4 71.4
41.9 69.5 43.5 71.6
42.0 69.6 43.6 71.7
42.1 69.7 43.7 71.9
42.2 69.9 43.8 72.0
42.3 70.0 43.9 72.1
42.4 70.1 44.0 72.2
平均 测区混凝土 平均 测区混凝土 4 回弹值 强度换算值(MPa) 回弹值 强度换算值(MPa)
Rm ƒccu,h,i Rm ƒccu,h,i
44.1 72.4 45.7 74.5
44.2 72.5 45.8 74.6
44.3 72.6 45.9 74.7
44.4 72.8 46.0 74.9
44.5 72.9 46.1 75.0
44.6 73.0 46.2 75.1
44.7 73.2 46.3 75.2
44.8 73.3 46.4 75.4
44.9 73.4 46.5 75.5
45.0 73.6 46.6 75.6
45.1 73.7 46.7 75.8
45.2 73.8 46.8 75.9
45.3 73.9 46.9 76.0
45.4 74.1 47.0 76.1
45.5 74.2 47.1 76.3
45.6 74.3 47.2 76.4 5 平均
回弹值 测区混凝土
强度换算值(MPa) 平均
回弹值 测区混凝土
强度换算值(MPa)
Rm ƒccu,h,i Rm ƒccu,h,i
47.3 76.5 49.0 78.7
47.4 76.7 49.1 78.9
47.5 76.8 49.2 79.0
47.6 76.9 49.3 79.1
47.7 77.0 49.4 79.2
47.8 77.2 49.5 79.4
47.9 77.3 49.6 79.5
48.0 77.4 49.7 79.6
48.1 77.6 49.8 79.7
48.2 77.7 49.9 79.9
48.3 77.8 50.0 80.0
48.4 78.0 50.1 80.1
48.5 78.1 50.2 80.2
48.6 78.2 50.3 80.4
48.7 78.3 50.4 80.5
48.8 78.5 50.5 80.6
48.9 78.6 50.6 80.8 6 平均 测区混凝土 平均 测区混凝土
回弹值 强度换算值(MPa) 回弹值 强度换算值(MPa)
Rm ƒccu,h,i Rm ƒccu,h,i
50.7 80.9 52.4 83.0
50.8 81.0 52.5 83.2
50.9 81.1 52.6 83.3
51.0 81.3 52.7 83.4
51.1 81.4 52.8 83.6
51.2 81.5 52.9 83.7
51.3 81.6 53.0 83.8
51.4 81.8 53.1 83.9
51.5 81.9 53.2 84.1
51.6 82.0 53.3 84.2
51.7 82.2 53.4 84.3
51.8 82.3 53.5 84.4
51.9 82.4 53.6 84.6
52.0 82.5 53.7 84.7
52.1 82.7 53.8 84.8
52.2 82.8 53.9 84.9
52.3 82.9 54.0 85.1 7 平均
回弹值 测区混凝土
强度换算值(MPa) 平均
回弹值 测区混凝土
强度换算值(MPa)
Rm ƒccu,h,i Rm ƒccu,h,i
54.1 85.2 56.1 87.7
54.2 85.3 56.2 87.8
54.3 85.4 56.3 87.9
54.4 85.6 56.4 88.1
54.5 85.7 56.5 88.2
54.6 85.8 56.6 88.3
54.7 85.9 56.7 88.4
54.8 86.1 56.8 88.6
54.9 86.2 56.9 88.7
55.0 86.3 57.0 88.8
55.1 86.4 57.1 88.9
55.2 86.6 57.2 89.1
55.3 86.7 57.3 89.2
55.4 86.8 57.4 89.3
55.5 86.9 57.5 89.4
55.6 87.1 57.6 89.6
55.7 87.2 57.7 89.7
55.8 87.3 57.8 89.8
55.9 87.4 57.9 90.0
56.0 87.6 8 附录B 回弹法检测混凝土抗压强度报告
编号( )第 号 第 页共 页
混凝土生产单位_______________ 委 托 单 位_____________
输 送 方 式________________设 计 单 位_____________
监 理 单 位________________监 督 单 位_____________
工 程 名 称________________构 件 名 称_____________
施 工 日 期________________检 测 原 因_____________
检 测 环 境________________检 测 依 据_____________
回弹仪生产厂_______________回弹仪编号____________
检 测 日 期________________回弹仪检定证号____________
检 测 结 果
构 件 混凝土抗压强度换算值(MPa) 现龄期混凝土 备注
名称 编号 平均值 标准差 强度推定值(Mpa)
(有需要说明的问题或表格不够请续页)
批准:______审核:______
主检______上岗证书号_______主检_______上岗证书号____
出具报告日期_____年_____月_____日 单位公章______ 9 十、回弹法检测高强
混凝土抗压强度技术规程
(1)总则
1.0.1 中华人民共和国行业标准《回弹法检测普通混凝土抗压强度技术规程》(JGJ/T23-2001),只适用于标准能量为2.2J的回弹仪检测构件强度为10~60MPa区段的混凝土的检测,随着高层建筑的日益增多,使得高强混凝土的应用亦日益增多。经试验研究发现原2.2J回弹仪的能量太小,无法适应高强混凝土的检测。一旦现场出现质量事故,无可靠方法解决。自1996年以来通过大量的实验,终于研制成功既适合现场使用又能满足测强曲线精度要求的大能量(5.5J)回弹仪,在此基础上,通过大量混凝土试件与回弹仪的试验,找到了精度较好的测强公式,从而较好地解决了使用大能量回弹仪检测现场高强混凝土的问题。
由于回弹仪的标准状态是直接影响检测结果准确与否的关键,同时现场构件检测时尚有许多具体检测内容例如测区数量、布置、构件强度推定等需要规定统一的方法,因此为保证检测精度有必要制定规程。
关于“高强混凝土”,中华人民共和国行业标准《普通混凝土配合比设计规程》(JGJ55-2000)条文说明第2.1.8条指出“在CEB-FIP模式规范中明确定义高强混凝土为”具有特征强度高于50MPa的混凝土。这个定义用的标准试件为
ф150mm×300mm园柱体,如果换算成以边长150mm的立方体