TPCS8210中文资料
- 格式:pdf
- 大小:429.48 KB
- 文档页数:7


专利名称:一种飞机航电系统多功能显示器图形显示控制模块专利类型:发明专利
发明人:郭小冬,杨永,闵博博,陈二虎,李文健
申请号:CN202010730453.5
申请日:20200727
公开号:CN112070654A
公开日:
20201211
专利内容由知识产权出版社提供
摘要:本发明公开了一种飞机航电系统多功能显示器图形显示控制模块,主要包含以下功能块:处理器:GX‑209H;SDRAM:H5TQ2G83EFR,256MB×8,64位宽;BIOS:SPI
FLASH,25VF032B,32Mbit;桥片:82574L,PCIE转LAN;电源管理:
5V,3.3V,1.8V,1.5V,0.95V;接口:COME Type6,本方案功能模块化集中,可扩展功能强大;元器件95%国产化,国产率提高,且功耗低,可靠性强;图形处理器数据处理能力强。
申请人:恒宇信通航空装备(北京)股份有限公司
地址:101300 北京市顺义区北石槽镇府前西街17号院4号1至6层101内2层201室
国籍:CN
更多信息请下载全文后查看。
tpc7062ti 规格书英文TPC7062TI Specification SheetProduct Overview:The TPC7062TI is a high-performance electronic component developed by TPC Co., Ltd. Based on advanced technology and rigorous testing, this specification sheet provides detailed information about the TPC7062TI and its various specifications.1. Introduction:The TPC7062TI is a versatile microcontroller that is widely used in various electronic devices and systems. With its robust features and reliable performance, it has gained popularity in the industry. This specification sheet aims to provide comprehensive details of the TPC7062TI for potential users and interested parties.2. General Specifications:- Microcontroller Family: TPC7- Model Number: 7062TI- Package Type: Integrated Circuit (IC)- Operating Voltage: 3.3V- Clock Speed: Up to 100 MHz- CPU Architecture: ARM Cortex-M3- Flash Memory: 256 KB- RAM: 32 KB- GPIO Pins: 46- ADC Channels: 12- UART Ports: 4- I2C Interfaces: 2- SPI Interfaces: 3- DMA Channels: 8- Operating Temperature Range: -40°C to +85°C3. Power Management:The TPC7062TI features efficient power management capabilities, ensuring optimal power consumption. It supports low-power modes, such as Sleep and Deep Sleep, allowing for extended battery life in battery-powered applications.4. Peripherals:The TPC7062TI is equipped with a wide range of peripherals, enabling seamless integration into various systems. Some of the key peripherals include:- Universal Asynchronous Receiver/Transmitter (UART): Allows for serial communication with external devices.- Inter-Integrated Circuit (I2C): Enables communication with peripheral devices using I2C protocol.- Serial Peripheral Interface (SPI): Supports high-speed synchronous data transfer with other devices.- Analog-to-Digital Converter (ADC): Enables analog signal measurement with high precision.- General-Purpose Input/Output (GPIO): Provides flexible digital signal I/O capabilities.- Direct Memory Access (DMA): Facilitates efficient data transfer between peripherals and memory.5. Security Features:To enhance system security, the TPC7062TI incorporates robust security features, including:- Advanced Encryption Standard (AES): Provides secure data encryption and decryption.- True Random Number Generator (TRNG): Generates random numbers for secure cryptographic operations.- Memory Protection Unit (MPU): Offers memory access control for improved system integrity and safety.6. Development Tools and Software:TPC offers a comprehensive set of development tools and software for the TPC7062TI. This includes an integrated development environment (IDE), compiler, debugger, and various libraries that facilitate easy development and debugging of applications using the TPC7062TI.7. Applications:The TPC7062TI is suitable for a wide range of applications, including but not limited to:- Home automation systems- Industrial control systems- Consumer electronics- Internet of Things (IoT) devices- Automotive electronicsConclusion:The TPC7062TI serves as a reliable and versatile microcontroller solution for various electronic systems and applications. Its comprehensive set of features, advanced security, and efficient power management make it an ideal choice for developers and engineers seeking high-performance embedded solutions.Note: This specification sheet is provided for informational purposes only and does not constitute a binding contract or purchase agreement. The specifications may be subject to change without prior notice. Customers are advised to contact TPC Co., Ltd. for the most up-to-date information regarding the TPC7062TI.End of Specification Sheet。
D escriptionT he 3M™ 8710, 8210, 8812 and 8822 Particulate Respirators provide eff ective respiratory protection for use in industries where workers will be exposed to dust particles and/or non-volatile liquid particles.T ested and certifi ed to AS/NZS 1716:2003.•T raditional convex shape, with nose clip and twin strap design.•D urable, collapse resistant inner shell.• R eliable, eff ective protection against fi ne particles.• 3M™ Advanced Electret Filter Material gives eff ective fi ltration •with low breathing resistance for consistent high quality performance. 3M™ Cool Flow™ exhalation valve off ers improved comfort in • h ot humid environments and/or where work is hard and physical*. M aterialsT he following materials are used in the production of the 8710, 8210, 8812 and 8822 Particulate Respirators:S traps • 8812, 8822 – Polyisoprene 8710 and 8210 – Thermoplastic Elastomer S taples • 8812, 8822 – Steel 8710 and 8210 – no staplesN ose Foam • P olyester N ose Clip • 8210 – Aluminium 8710, 8812, 8822 – Steel F ilter •P olyester / Polypropylene V alve* • P olypropylene V alve diaphragm* • P olyisopreneThese products do not contain components made from natural rubber latex.M aximum mass of products:• U nvalved (8710 & 8210) = 8g •V alved (8812 & 8822) =13gS tandardsThese products meet the requirements of Australian New Zealand Standard AS/NZS 1716:2003, Respiratory protective devices. They should be used to protect the wearer from solid and non-volatile liquid particles only.P articulate Filter Respirators are classifi ed by fi ltering effi ciency and maximum total inward leakage performance (P1 & P2), also by inhalation resistance.P 1 fi lters are indended for use against mechanically generatedparticulates such as those generated from sanding, grinding, drilling, sweeping etc.P2 fi lters are intended for use against both mechanically and thermally generated particulates e.g. welding, brazing etc. P2 fi lters may also help reduce breathing in pathogenic biological airborne particulates such as infl uenza virus.A pprovalsT hese respirators have been produced to comply with the requirements of the Australian / New Zealand Standard AS/NZS 1716:2003 under an agreed production certifi cation scheme operated during manufacture in accordance with the SAI Global StandardsMark programme.A pplicationsT hese respirators are suitable for use in concentrations of solid andnon-volatile liquid particles up to the following limits:E S = Exposure Standard Respiratory protection is only eff ective if it is correctly selected, fi tted and worn throughout the time when the wearer is exposed to hazards.3M ™8710, 8210, 8812 and 8822P articulate Respirators* 8812 and 8822 models onlyDatasheetS electionGuidethe most appropriate personal protective equipment (PPE) will depend on the particular situation and should be made only by a competent person knowledgeable of the assessed risks, actual working conditions and limitations of PPE. Details regarding performance and limitations are set out on the product packaging and user information. If in doubt, contact a safety professional or 3M.For respiratory training and advice please contact your local 3M representative.S torage and TransportationT he 3M™ 8710, 8210, 8812 and 8822 Particulate Respirators have a shelf life of 3 years. End of shelf life is marked on the product packaging. Before initial use, always check that the product is within the stated shelf life (use by date). Product should be stored in clean, dry conditions within the temperature range: – 20°C to + 25°C with a maximum relative humidity of <80%. When storing or transporting this product use original packaging provided.D isposalC ontaminated products should be disposed as hazardous waste in accordance with local regulations.Fitting Instructions 8710 and 8210 onlyS ee Figure 1. a nd 1. 2 . Pre-stretch around entire length of each strap bypulling at 3cm intervals between both hands.C up respirator in one hand with nosepiece at fi ngertips, allow 3. headbands to hang freely below hand. H old respirator under chin, with nosepiece up.4. L ocate the upper strap across the crown of the head and the 5. lower strap below the ears. S traps must not be twisted.6. U sing both hands, mould noseclip to the shape of the lower7. part of the nose to ensure a close fi t and good seal. Pinching the noseclip using only one hand may result in less eff ective respirator performance.T he seal of the respirator on the face should be fi t-checked 8. before entering the workplace.F igure 18812 and 8822 onlyS ee Figure 2. C up respirator in one hand with nosepiece at fi ngertips, allow1. headbands to hang freely below hand. H old respirator under chin, with nosepiece up.2. L ocate the upper strap across the crown of the head and the3. lower strap below the ears. S traps must not be twisted.4. U sing both hands, mould noseclip to the shape of the lower5. part of the nose to ensure a close fi t and good seal. Pinching the noseclip using only one hand may result in less eff ective respirator performance.T he seal of the respirator on the face should be fi t-checked 6. before entering the workplace.F igure 2F it CheckC over the front of the respirator with both hands being careful1. not to disturb the fi t of the respirator.(a) UNVALVED respirator - EXHALE sharply;2. (b) VALVED respirator - INHALE sharply.I f air leaks around the nose, re-adjust the noseclip to 3. eliminate leakage. Repeat the above fi t check.I f air leaks at the respirator edges, work the straps back 4. along the sides of the head to eliminate leakage. Repeat the above fi t check.I f you CANNOT achieve a proper fi t DO NOT enter the hazardous area. S ee your supervisor . U sers should be fi t tested in accordance with AS/NZS 1715. F or information regarding fi t testing procedures, please contact 3M.Please recycle.© 3M 2010. All rights reserved.Important Notice3M does not accept liability of any kind, be it direct or consequential (including, but not limited to, loss of profi ts, business and/or goodwill)arising from reliance upon any information herein provided by 3M. The user is responsible for determining the suitability of the products for their intended use. Nothing in this statement will be deemed to exclude or restrict 3M’s liability for death or personal injury arising from its negligence.Occupational Health andEnvironmental Safety Division 3M Australia Pty Ltd950 Pacifi c Highway Pymble NSW 2073Phone: 136 136Fax: 02 9498 9616TechAssist Helpline: 1800 024 464E-mail:******************.au Website: /au/ohsOccupational Health and Environmental Safety Division 3M New Zealand Ltd94 Apollo Drive, Albany,North Shore City, 0632 Tech Helpline: 0800 364 357Customer services: 0800 252 627Fax: 0800 367 253E-mail:*****************.com Website : /safetyE U _M A S T E R _018710 respirator8210 respirator8812 respirator8822respiratorW arnings and Use LimitationsA lways be sure that the complete product is:• - Suitable for the application;- Fitted correctly;- Worn during all periods of exposure;- Replaced when necessary. P roper selection, training, use and appropriate maintenance are • essential in order for the product to help protect the wearer from certain airborne contaminants. F ailure to follow all instructions on the use of these respiratory • protection products and/or failure to properly wear the complete product during all periods of exposure may adversely aff ect the wearer’s health, lead to severe or life threatening illness or permanent disability. F or suitability and proper, use follow local regulations, refer to all • information supplied or contact an occupational hygienist, safety professional or 3M representative on the Tech Assist Helpline 3M Australia 1800 024 464, 3M New Zealand 0800 364 357. B efore use, the wearer must be trained in use of the complete • product in accordance with applicable Health and Safety standards/guidance.T hese products do not contain components made from natural • rubber latex. T hese products do not protect against gases/vapours.• D o not use in atmospheres containing less than 19.5% oxygen. • (3M defi nition. Individual countries may apply their own limits on oxygen defi ciency.Seek advice if in doubt). D o not use for respiratory protection against atmospheric contami-• nants/concentrations which are unknown or immediately danger-ous to life and health (IDLH). D o not use with beards or other facial hair that may inhibit contact between the face and the product thus preventing a good seal. L eave the contaminated area immediately if:• a) Breathing becomes diffi cult.b) Dizziness or other distress occurs. D iscard and replace the respirator if it becomes damaged,• breathing resistance becomes excessive or at the end of the shift. N ever alter, modify or repair this device.• I n case of intended use in explosive atmospheres, contact 3M.• P roductRange。