VFS3320-5DZ-03 SMC电磁阀
- 格式:doc
- 大小:1.39 MB
- 文档页数:6
电磁阀VUVG/阀岛VTUGSubject to change –2017.062→Internet:/catalogue/...电磁阀VUVG主要特性创新通用可靠易安装•可设置为内先导或外先导,用于板式阀阀组•通过电接口插件可方便地更换连接技术•最大压力10bar •结构特点:–活塞滑阀,带密封圈(VUVG-LK,VUVG-BK)–活塞滑阀,带密封阀芯(VUVG-L,VUVG-B)•多种阀功能•可选快插接头•管式阀•板管式阀可用作气路板集成安装•M5和M7管式阀可组合在一块气路板上•气路板带多个压力分区•IP40,IP65•坚固耐用的金属元件–阀–气路板•快速排除故障,得益于360°LED 显示•可快捷地更换阀片,维护便利•可选手控装置:按钮式,封盖式,按钮式/锁定式或锁定式(不带附件)•牢固地安装到墙面或H 型导轨•随带螺丝和密封件,安装方便•通过电接口插件可方便地更换连接技术•标签支架,用于阀的标签阀岛配置器CAD 相关数据→阀岛配置器帮助您选择正确的阀岛VTUG ,订购正确的产品更方便。
阀岛VTUG 通过订货代码订购。
所有阀岛供货时已装配完毕并单独做过测试。
最大限度减少了装配和安装时间。
订货系统,用于阀岛VTUG →Internet:vtug-V-新产品VUVG-LK,VUVG-BK2017.06–Subject to change 3Internet:/catalogue/...电磁阀VUVG主要特性–气动元件单个阀和阀岛管式阀用作单个阀管式阀VUVG-LK/VUVG-L管式阀可无需气动耦合就可使用。
所有气接口位于阀上,可配备接头/气管。
电接口有多种不同的电接口插件可选。
如果使用过了特殊密封套件,管式阀VUVG 还可作为半管式阀安装在气路板(气动耦合)上。
板管式阀可用作气路板集成安装半管式阀VUVG-S阀岛VTUG 由半管式阀VUVG-S 组成对于半管式阀,进气口(1,3和5)通过气动耦合(如,气路板)与阀连接。
Instruction Manual5 Port Solenoid Valve/Cassette Type ManifoldSeries SZ3000The intended use of this valve is to control the movement of an actuator.1 Safety InstructionsThese safety instructions are intended to prevent hazardous situationsand/or equipment damage. These instructions indicate the level ofpotential hazard with the labels of “Caution,” “Warning” or “Danger.”They are all important notes for safety and must be followed in additionto International Standards (ISO/IEC) *1), and other safety regulations.*1) ISO 4414: Pneumatic fluid power - General rules relating to systems.ISO 4413: Hydraulic fluid power - General rules relating to systems.IEC 60204-1: Safety of machinery - Electrical equipment of machines.(Part 1: General requirements)ISO 10218-1: Robots and robotic devices - Safety requirements forindustrial robots - Part 1: Robots.•Refer to product catalogue, Operation Manual and HandlingPrecautions for SMC Products for additional information.• Keep this manual in a safe place for future reference.Caution Caution indicates a hazard with a low level of risk which, ifnot avoided, could result in minor or moderate injury.Warning Warning indicates a hazard with a medium level of riskwhich, if not avoided, could result in death or serious injury.Danger Danger indicates a hazard with a high level of risk which, ifnot avoided, will result in death or serious injury.Warning•Always ensure compliance with relevant safety laws andstandards.•All work must be carried out in a safe manner by a qualified person incompliance with applicable national regulations.Caution•The product is provided for use in manufacturing industries only. Donot use in residential premises.2 Specifications2.1 Valve specificationsFluid AirInternal pilotoperatingpressurerange [MPa]2 position single 0.15 to 0.72 position double 0.1 to 0.73 position 0.2 to 0.74 position dual 3 port 0.15 to 0.7External pilotpressurerange [MPa]Operating pressure range -100 kPa to 0.7Pilotpressurerange2 position single0.25 to 0.72 position double3 positionAmbien and fluid temperature [˚C]-10 to 50 (No freezing)Flow rate characteristicsRefer to catalogueResponse timeDuty cycle Contact SMCMinimum operating frequency 1 cycle / 30 daysMaximumoperatingfrequency [Hz]2 position single, double,4 position dual 3 port valve103 position 32 Specifications - continuedManual override (manual operation)Non-locking push typePush-turn locking slotted typeLubrication Not requiredImpact/Vibration resistance [m/s2] Note 150 / 30Enclosure (based on IEC60529) IP40Mounting orientation UnrestrictedWeight Refer to cataloguePilot type Common exhaustTable 1.Note 1) Impact resistance: No malfunction occurred when it was tested in the axialdirection and at right angles to the main valve and armature in bothenergized and de-energized states. Each condition was tested once.(Values quoted are for a new valve).Vibration resistance: No malfunction occurred in a one-sweep test between45 and 2000 Hz. Test was performed in both energized and de-energizedstates in the axial direction and at right angles to the main valve andarmature. (Values quoted are for a new valve).2.2 Solenoid specificationsElectricalentryPlug-in, EX140, EX510 L type plug connector (L)Non plug-in M type plug connector (M)Coil rated voltage [VDC] 24, 12Allowable voltage fluctuation ±10% of rated voltageCoil insulation class Contact SMCPower consumption [W] 0.6 (With light: 0.65)Surge voltage suppressor DiodeIndicator light LEDTable 2.Note 1) Only 24 VDC and 12 VDC are available for plug-in use.2.3 Manifold specificationsModelD-subType 60FFlat ribbon cable type 60P#SS5Z3-60Type 60P Type 60PG Type 60PHManifold type Plug-in (L)Non plug-in(M)1(P:SUP)/3/5(R: EXH) systemCommon SUP, EXHValve stations 2 to 20 2 to 16 2 to 8 2 to 204(A)/2(B)portLocation ValveDirection Lateral, upward, downwardPortsize1(P), 3/5(R) C84(A), 2(B) C4, C6, M5Table 3.2.4 Pneumatic symbolsRefer to catalogue Pneumatic symbols.2.5 Indicator lightM type plug connector L type plug connectorFigure 1.2.6 Special productsWarningSpecial products (-X) might have specifications different from thoseshown in this section. Contact SMC for specific drawings.3 Installation3.1 InstallationWarning•Do not install the product unless the safety instructions have been readand understood.3.2 EnvironmentWarning•Do not use in an environment where corrosive gases, chemicals, saltwater or steam are present.3 Installation - continued•Do not use in an explosive atmosphere.•Do not expose to direct sunlight. Use a suitable protective cover.•Do not install in a location subject to vibration or impact in excess ofthe product’s specifications.•Do not mount in a location exposed to radiant heat that would result intemperatures in excess of the product’s specifications.3.3 PipingCaution•Before connecting piping make sure to clean up chips, cutting oil, dustetc.•When installing piping or fittings, ensure sealant material does notenter inside the port. When using seal tape, leave 1 thread exposedon the end of the pipe/fitting.•Tighten fittings to the specified tightening torque.3.4 LubricationCaution•SMC products have been lubricated for life at manufacture, and do notrequire lubrication in service.•If a lubricant is used in the system, refer to catalogue for details.3.5 Air supplyWarning•Use clean air. If the compressed air supply includes chemicals,synthetic materials (including organic solvents), salinity, corrosive gasetc., it can lead to damage or malfunction.Caution•Install an air filter upstream of the valve. Select an air filter with afiltration size of 5 μm or smaller.3.6 Manual overrideWarning•Regardless of an electric signal for the valve, the manual override isused for switching the main valve. Since connected equipment willoperate when the manual override is activated, confirm that conditionsare safe prior to activation.•Locked manual overrides might prevent the valve responding to beingelectrically de-energised or cause unexpected movement in theequipment.•Refer to the catalogue for details of manual override operation.Non-locking push type Push-turn locking slotted typeFigure 2. – Position is the same on L and M types3.7 Valves with switches (L type plug-in only)WarningWhen turning OFF with the switch, be sure to move the switch to thelocked position. Connected equipment may be actuated if current flowoccurs with the switch at an improper position.ON position OFF positionNormal operating condition.Switching off valve is based onan electric signal from theconnector.The valve coil is kept in adeenergized state even when thereis an electric signal from theconnector.Figure 3.3 Installation - continued3.8 Electrical circuitsCautionIf a valve type without suppression is used, suppression should beprovided as close as possible to the valve by the host controller.Pos. common specifications Neg. common specificationsSingle solenoid type Single solenoid typeLight/surge voltage suppressorSurge voltage suppressorDouble solenoid, 3 position,4 positionDouble solenoid, 3 position,4 positionLight/surge voltage suppressorSurge voltage suppressorValves with switches (with light/surge voltage suppressor)-Figure 4.Note) Make sure that the polarity is matched on the connector’s (+), (-) and A, Band COM indicators. In case of voltage specifications other than 12 or 24VDC, take care to avoid mistaking polarity, as there is no diode to preventreverse current. In the event that lead wires are connected in advance, theywill be as shown below.Pos. common specifications Neg. common specificationsA (-): BlackCOM (+): RedB (-): White (no lead wire forsingle solenoid)A (+): BlackCOM (-): RedB (+): White (no lead wire for singlesolenoid)3.9 Residual voltageCaution•The suppressor arrests the back EMF voltage from the coil to a levelin proportion to the rated voltage.ORIGINAL INSTRUCTIONSSol.AManual overridefor Sol.B (Green)Manual overridefor Sol.A (Orange)Sol.BSol.AManual overridefor Sol.B (Green)Manual overridefor Sol.A (Orange)Sol.BSolenoid ASolenoid BLightA: RedB: GreenDiode to preventreverse currentCoilCOMRed (+)[SOL.a]Black (-)LED(Red)Diode to preventreverse currentCoilCOMYellow (-)[SOL.a]Black (+)LED(Red)Diode to preventreverse currentCoilCOMRed (+)[SOL.a]Black (-)Diode to preventreverse currentCoilCOMYellow (-)[SOL.a]Black (+)Diode to preventreverse currentCoil[Sol.b]White (-)[SOL.a]Black (-)LED(Red)COMRed (+)CoilLED(Green)Diode to preventreverse currentCoil[Sol.b]White (-)[SOL.a]Black (-)COMRed (+)CoilDiode to preventreverse currentCoil[Sol.b]White (+)[SOL.a]Black (+)LED(Red)COMYellow (-)CoilLED(Green)Diode to preventreverse currentCoil[Sol.b]White (+)[SOL.a]Black (+)COMYellow (-)CoilSwitchCoil[Sol.b](-)[SOL.a](-)SwitchCoilCOM(+)LED(Green)LED(Red)3 Installation - continued•Ensure the transient voltage is within the specification of the hostcontroller.•In the case of a diode, the residual voltage is approximately 1 V.•Valve response time is dependent on surge suppression methodselected.3.10 Countermeasure for surge voltageCaution•At times of sudden interruption of the power supply, the energy storedin a large inductive device may cause non-polar type valves in a de-energised state to switch.•When installing a breaker circuit to isolate the power, consider a valvewith polarity (with polarity protection diode), or install a surgeabsorption diode across the output of the breaker.3.11 Extended period of continuous energizationWarningIf a valve will be continuously energized for an extended period of time,the temperature of the valve will increase due to the heat generated bythe coil assembly. This will likely adversely affect the performance of thevalve and any nearby peripheral equipment. Therefore, if the valve is tobe energized for periods of longer than 30 minutes at a time or if duringthe hours of operation the energized period per day is longer than the de-energized period, we advise using a 0.4 W or lower valves, such as theSY series, or a valve with power-saving circuit.3.12 Effect of back pressure when using a manifoldWarning•Use caution when valves are used on a manifold because an actuatormay malfunction due to back-pressure.•Special caution must be taken when using 3 position exhaust centrevalve or when driving a single acting cylinder. To prevent amalfunction, implement counter measures such as using a single EXHspacer assembly or an individual exhaust manifold.3.13 Manifold electrical wiring specificationsRefer to catalogue for manifold electrical wiring specifications.3.14 How to use plug connectorRefer to catalogue for additional information.3.14.1 Attaching and detaching connectorsFigure 5.3.14.2 Crimping of lead wires and socketsFigure 6.3.14.3 Attaching and detaching lead wires with socketsFigure 7.3 Installation - continued3.15 Common connector assembly wiringRefer to catalogue for additional information.Figure 8. Common connector assembly wiring3.16 Exhaust restrictionCautionSince the SZ series is a type in which the pilot valve exhaust joins themain valve exhaust inside the valve, care must be taken that the pipingfrom the exhaust port is not restricted.3.17 Use as a 3-port valveCautionThe SZ3000 series valves can be used as normally closed (N.C.) ornormally open (N.O.) 3 port valves by closing one of the cylinder ports (Aor B) with a plug. However, they should be used with the exhaust portskept open. They are convenient at times when a double solenoid type 3port valve is required.Plug position B port A portType of actuation N.C. N.O.NumberofsolenoidsSingleDoubleTable 4.3.18 One-touch fittings3.18.1 Tube attachment and detachmentCautionRefer to the Specific Precautions in the catalogue.3.18.2 Precautions on other tube brandsCautionWhen using non-SMC brand tubes, refer to the Specific Precautions inthe catalogue.3.19 Built-in back pressure check valveCaution•Valves with built-in back pressure check valve is to protect the backpressure inside a valve. For this reason, use caution that the valveswith external pilot specification cannot be pressurized from exhaustport [3(R)]. As compared with the types which do not integrate the backpressure check valve, C value of the flow rate characteristics goesdown. For details, please contact SMC.•Do not switch valves when A or B port is open to the atmosphere, orwhile the actuators and air operated equipment are in operation. Theback pressure prevention seal may be peeled off, which may cause airleakage or malfunctions. Use caution especially when performing atrial operation or maintenance work.4 Settings4.1 Changing the connector entry directionCaution•Since lead wires are attached to the connector, excessive pulling ortwisting can cause broken wires or other issues. Also, take care thatlead wires are not pinched when installing the connector.•If an excessive force is applied on the connector in the ‘LOCK’ position,the connector block may be damaged. Connector lead wires maybreak If the switch is in the ‘FREE’ position during operation. Ensurethe switch is moved back in ‘LOCK’ position.•Refer to catalogue for additional information.Figure 9.5 How to OrderRefer to catalogue for ‘How to Order’ or to product drawing for specialproducts.6 Outline DimensionsRefer to catalogue for outline dimensions.7 Maintenance7.1 General maintenanceCaution•Not following proper maintenance procedures could cause the productto malfunction and lead to equipment damage.•If handled improperly, compressed air can be dangerous.•Maintenance of pneumatic systems should be performed only byqualified personnel.•Before performing maintenance, turn off the power supply and be sureto cut off the supply pressure. Confirm that the air is released toatmosphere.•After installation and maintenance, apply operating pressure andpower to the equipment and perform appropriate functional andleakage tests to make sure the equipment is installed correctly.•If any electrical connections are disturbed during maintenance, ensurethey are reconnected correctly and safety checks are carried out asrequired to ensure continued compliance with applicable nationalregulations.•Do not make any modification to the product.•Do not disassemble the product, unless required by installation ormaintenance instructions.7.2 Fitting assembly replacementRefer to catalogue for additional information.Figure 10.7.3 Manifold expansion and replacement parts•When disassembly and assembly are performed, air leakage mayresult if connections between blocks and tightening of the end block’sholding screw, is inadequate. Before supplying air, confirm that thereare no gaps, etc. between blocks, and that manifold blocks aresecurely fastened to the DIN rail. Then supply air and confirm that thereis no air leakage before operating.•Tighten the DIN rail holding screw to the recommended torque of 1.4N∙m.•Refer to catalogue for additional information and replacement parts.8 Limitations of Use8.1 Limited warranty and disclaimer/compliance requirementsRefer to Handling Precautions for SMC Products.Warning8.2 Cannot be used as an emergency shut-off valveThis product is not designed for safety applications such as anemergency shut-off valve. If the valves are used in this type of system,other reliable safety assurance measures should be adopted.8.3 Holding of pressure (including vacuum)Since valves are subject to air leakage, they cannot be used forapplications such as holding pressure (including vacuum) in a system.8.4 Intermediate stoppingRefer to Handling Precautions for 3/4/5 port Solenoid Valves.8.5 Air returned or air/spring returned spool valves•The use of 2-position single valves with air returned or air/springreturned spools has to be carefully considered.•The return of the valve spool into the de-energized position dependson the pilot pressure. If the pilot pressure drops below the specifiedoperating pressure the position of the spool cannot be defined.•The design of the system must take into account such behaviour.•Additional measures might be necessary. For example, the installationof an additional air tank to maintain the pilot pressure. Such measuresmust be evaluated by risk assessment within the validation process.EnergysourcestatusSingle Double 3 position 4 positionAir supplypresent,electricitycutSpool returns tothe off positionby air forceSpool stopsmoving afterelectricity cut(Position cannotbe defined)Spool returnsto off positionby spring forceSpools return tooff position by airforceAir supplycut beforeelectricitycutSpool stopsmoving after airpressure cut(Position cannotbe defined)Spool stopsmoving after airpressure cut(Position cannotbe defined)Spool returnsto off positionby spring forceSpool stopsmoving after airpressure cut(Position cannotbe defined)Table 5.Caution8.6 Leakage voltageEnsure that any leakage voltage caused by the leakage current when theswitching element is OFF is ≤ 3% of the rated voltage across the valve.8.7 Low temperature operationUnless otherwise indicated in the specifications for each valve, operationis possible to -10˚C, but appropriate measures should be taken to avoidsolidification or freezing of drainage and moisture, etc.8.8 Momentary energizationIf a double solenoid valve is operated with momentary energization, itshould be energized for at least 0.1 second. However, depending on thesecondary load conditions, it should be energized until the cylinderreaches the stroke end position, as there is a possibility of malfunctionotherwise.9 Product DisposalThis product shall not be disposed of as municipal waste. Check yourlocal regulations and guidelines to dispose this product correctly, in orderto reduce the impact on human health and the environment.10 ContactsRefer to or www.smc.eu for your localdistributor/importer.URL : https:// (Global) https:// www.smc.eu (Europe)SMC Corporation, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JapanSpecifications are subject to change without prior notice from the manufacturer.© 2022SMC Corporation All Rights Reserved.Template DKP50047-F-085M CoverConcavePinLeverPolarity indicatorSocketPart no. DXT170-71-1Lead wireConnectorHookCore wirecrimping areaCrimping areaCore wireLead wireSocketHookInsulation0.2 mm2 to 0.33 mm2Max. cover diameter: ∅1.7 mmSocketHookConnectorLead wireInsert into these square holesSwitch for locking a connectorM5 port block assemblyClipO-ringC4 / C6 one-touch fittingO-ringOne-touch fitting(Elbow type)One-touch fitting(Long elbow type)Common wireSocketInsert socket into connector (below COM indicator)of adjacent solenoid valve。
脉冲式电磁阀据兰州市环保局新闻发言人介绍,兰州市七里河区与安宁区污水处理厂已经建成,日处理能力20万吨,计划今年9月正式投入使用。
兰州市今年还将投资3800万元,对七里河区、安宁区污水管网进行扩建,目前工程已开工建设,预计9月底完成。
工程完工后将减少黄河七里河区段、安宁区段污水排放口117处。
发言人表示,兰州今后仍将继续加大污水治理力度。
兰州市的目标是到2010年将全市污水处理率提高到70%以上,全市化学需氧量排放总量控制在4.67万吨以内,比“十五”末消减13.4%。
兰州地处黄河上游地带,是黄河唯一穿城而过的省会城市。
黄河兰州段全长152公里,其中流经兰州市区45公里,为兰州市提供了主要的生产和生活用水。
黄河流经兰州后,水质却大大下降,主要受兰州城市生活污水和工业废水污染。
2006年,兰州全市废水排放量为超过1.6亿吨,其中工业废水排放量约为0.42亿吨,占25%;生活及其他污水排放量1.2亿首页>>产品中心>>ZBF22Q自保持电磁球阀一、概述:ZBF22Q-6~250型电磁球阀是二位二通自保持自动阀门,其开(关)阀由内、外部回路共同控制,当开(关)阀信号接通时,线圈励磁,产生旋转力矩,带动球阀阀芯转动,阀芯转到全开(关)位置时,阀内部机构自断电,阀保持开(关)位置。
本阀采用球面密封,它比传统线密封的电磁阀密封性能更好,使用寿命更长;其线圈因瞬时带电,节省电能,延长使用寿命。
ZBF22Q-6~250型电磁球阀适用空气、油、水等无强腐蚀性流体。
工作时,对流体的流向不作要求,对流体的进、出口压力不作要求,对介质的清洁度不作严格要求,可广泛用于电力、石油、化工、冶金等部门,用以远程控制管道中介质的流通与中断。
二、典型用途:1、控制电站冷却用水2、电站密封用水3、电站供油管道油路的开断。
三、特点:1.本阀采用球阀结构,增强密封性能,延长使用寿命。
2.线圈瞬时带电,避免传统电磁阀因长期带电易烧线圈而无法工作。
SMC电磁阀SY5120-5LZD-01适用环境和介质SMC电磁阀SY5120-5LZD-01是用来控制液压系统中油液的流动方向或调节其压力和流量的,因此它可分为方向阀、压力阀和流量阀三大类。
一个形状相同的阀,可以因为作用机制的不同,而具有不同的功能。
压力阀和流量阀利用通流截面的节流作用控制着系统的压力和流量,而方向阀则利用通流通道的更换控制着油液的流动方向。
这就是说,尽管SMC电磁阀存在着各种各样不同的类型,它们之间还是保持着一些基本共同之点的。
SMC电磁阀SY5120-5LZD-01适用环境
a、环境的高低温度应选在允许范围之内,如有超差需作特殊提出。
b、环境中相对湿度高及有水滴雨淋等场合,应选防水电磁阀。
c、环境中经常有振动,颠簸和冲击等场合应选特殊品种,例如船用电磁阀。
d、在有腐蚀性或爆炸性环境中的使用应优先根据安全性要求选用耐发蚀。
e、环境空间若受限制,请选用多功能电磁阀,因其省去了旁路及三只手动阀且便于在线维修。
SMC电磁阀SY5120-5LZD-01适用介质:
1、气液态或混合状态分别选用不同品种的电磁阀。
2、介质温度不同规格产品,否则线圈会烧掉,密封件老化,严重影响寿命。
介质温度应选在电磁阀允许范围之内。
3、介质粘度,通常在50cSt以下。
若超过此值,通径小于15mm 订高粘度电磁阀。
4、介质清洁度不高时都应在电磁阀前配装反冲过滤阀。
介质若是定向流通,且不允许倒流。
Direct mounting (PF3W511)Mount using the self tapping screws(nominal size: 4.0 x 4 pcs.) for installation.The tightening torque must be 1 to 1.2 Nm.The self tapping screws cannot be re-used.Refer to the outline dimension drawing for mounting hole size.Refer to the product catalogue or SMC website (URL )for more detailed information.Direct mounting (PF3W504/520/540)Mount using the self tapping screws(nominal size: 3.0 x 4 pcs.) for installation.For models with flow adjustment valveattached, mount using 8 self tapping screws.The tightening torque must be 0.5 to 0.7 Nm.Supply powerApprox. 3 seconds(the output remains off for this period)Piping port (OUT side)(4 pins) (Option)FLOW indicatorPOWER indicator*: Green: Flashes once. PF3W5--1 (Analogue 1 to 5 V type: Without temperature sensor)Flashes twice. PF3W5-Flashes three times. PF3W5The POWER indicator (Green) turns on, and the FLOW indicator flashes according to the flow rate.Mounting and InstallationFlow SensorOperation ManualPF3W5Safety InstructionsThese safety instructions are intended to prevent hazardous situations and/or equipment damage.These instructions indicate the level of potential hazard with the labels of"Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations.OperatorNOTEThe direct current power supply to be used should be UL approved as follows.Circuit (of class 2) which is of maximum 30 Vrms (42.4 V peak), with UL 1310class 2 power supply unit or UL 1585 class 2 transformer.The product is a approved product only if it has a mark on the body.InstallationBracket mounting (PF3W504/520/540)Mount the product (with bracket) using the mounting screws supplied (M4 x 4 pcs.).For models with flow adjustment valve attached, fix using 8 mounting screws.Bracket thickness is approx. 1.5 mm.Bracket mounting (PF3W511)Mount the product (with bracket) using the mounting screws supplied (M5 x 4 pcs.).Bracket thickness is approx. 2 mm.Measurement modeThe mode in which the flow is detected and the FLOW indicator flashes, and analogue output is operating.TroubleshootingError indicationcontact SMC.MaintenanceHow to reset the product after a power cut or when the power has been unexpectedly removedThe output condition also recovers to that before the power cut or de-energizing,but may change depending on the operating environment.Therefore, check the safety of the whole system before operating the product.SpecificationRefer to the product catalogue or SMC website (URL ) for more detailed information about product specifications.DimensionsRefer to the product catalogue or SMC website (URL ) for more detailed information about dimensions.© 2010-2011 SMC Corporation All Rights ReservedURL BodyDisplayInstallation•Use the product within the specified operating pressure and temperature range.•Proof pressure could vary according to the fluid temperature.Check the characteristics data for operating pressure and proof pressure.Mounting•Never mount the product in a location where it will be used as a support.•Mount the product so that the fluid flows in the direction indicated by the arrow on the side of the body.•Check the flow characteristics data for pressure loss and the straight inlet pipe length effect on accuracy, to determine inlet piping requirements.•Do not sharply reduce the piping size.PipingWhen connecting piping to the product, a spanner should be used on the metal piping attachment only.Using a spanner on other parts may damage the product.In particular, do not let the spanner come into contact with the M8 connector.The connector can be easily damaged.Width across flats of attachmentIf the tightening torque is exceeded, the product can be broken. If the correct tightening torque is not applied, the fittings may become loose.Avoid any sealing tape getting inside the piping.Ensure there is no leakage from loose piping.3/824 mm 1/227 mm 3/432 mm Tighten to the specified torque for piping.141 mm WiringWiring of connectorConnections should only be made with the power supply turned off.Use separate routes for the Flow sensor wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise.Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply isconnected to the product, switching noise will be superimposed and the product specification can no longer be met. This can be prevented by inserting a noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the product, or by using a series power supply instead of a switch-mode power supply.How to adjust the flow rate(when a flow adjustment valve is mounted)(1) Rotate the knob of the valve to adjust the flow rate to the target value.(2) Be sure to confirm that there is no fluid leakage generated after adjustment.the valve several times for re-adjustment, and confirm that there is no fluid leakage.)The flow adjustment valve is not designed for applications that require daily and repetitive adjustment.If the valve is adjusted frequently, fluid may leak due to wear of the internal seal.Refer to the product catalogue or SMC website (URL )for more detailed information.11/454 mm 11/254 mmRefer to the SMC website (URL ) for more detailed information about product troubleshooting.Thank you for purchasing an SMC PF3W5 Series Flow Sensor.Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations.Please keep this manual handy for future reference.To obtain more detailed information about operating this product,please refer to the SMC website (URL ) or contact SMC directly.。
S M C比例阀工作原理标准化管理处编码[BBX968T-XBB8968-NNJ668-MM9N]SMC比例阀工作原理[SMC ITV系列电气比例阀] 电气比例阀通过电信号控制气压力,可以实现气压力的连续、无级调节,能实现远程控制和程序控制,对于需要对气压力进行连续或者无级调节的场合,特别适用于电气比例阀。
对于SMC ITV系列电气比例阀有以下特点:1、灵敏度高、性能好。
保护等级为IP65.电缆方向有直线型和直角型。
2、SMC ITV0000系列为薄型(仅15mm),轻(100g)。
最多可集装至10位。
响应快(无负载时为)。
快换接头链接。
带错误显示灯(LED)。
3、SMC ITV2000/ITV3000系列为正压型,设定压力范围有三档。
在平衡状态时耗气量为0.在不加压状态下,可进行零位调整和满位调整。
在加压状态下若断电,能暂时保持输出压力不变。
有两种监控方式(模拟输出、开关输出)可供选择。
4、SMC ITV系列电气比例阀配线方法把电缆接到本体插座上应按SMC ITV系列电器使用说明书上的配线图进行配线。
配线一旦失误,阀可能损坏。
另外,DC电源应使用容量足够、电压波动小的电源。
5、SMC ITV系列电气比例阀特性曲线参见SMC ITV系列电气比例阀样本6、SMC ITV系列电气比例阀使用注意事项1)SMC ITV电气比例阀之前,应设置5μm以下过滤精度和油雾分离器,保证气源处理系统达到SMC压缩空气清净化系统第④系列的要求,向ITV比例阀提供清洁干燥的压缩空气,以便能达到ITV电气比例阀应有的各种特性。
2)SMC ITV电气比例阀之前,不得装油雾器。
3)SMC ITV电气比例阀在加压状态下切断电源,出口侧压力能暂时保持,但不能一直保持。
*SMC ITV电气比例阀其它使用注意事项,请参见SMC ITV系列电器使用说明书。
SMC ITV系列电气比例阀型号列表SMC ITV系列电气比例阀样本SMC ITV系列电气比例阀使用说明书SMC ITV电气比例阀配线图2、SMC ITV系列电气比例阀动作原理[SMC ITV系列电气比例阀动作原理图]SMC ITV2000/ITV3000系列电气比例阀动作原理图1-供气先导阀 2-膜片 3-排气阀 4-供气阀芯 5-先导室 6-压力传感器 7-排气先导阀8-控制回路[SMC ITV系列电气比例阀控制框图]SMC ITV2000/ITV3000系列电气比例阀控制框图SMC ITV2000/ITV3000系列电气比例阀动作原理图控制框图如上所示。
http://www.diancifa.cc
1
产品名称:VFS3320-5DZ-03 SMC电磁阀
4 电磁阀(Electromagneticvalve)是用电磁控制的工业设备,是用来控制流体的自动化基础元件,
属于执行器,并不限于液压、气动。用在工业控制系统中调整介质的方向、流量、速度和其他的参
数。电磁阀可以配合不同的电路来实现预期的控制,而控制的精度和灵活性都能够保证。电磁阀有
很多种,不同的电磁阀在控制系统的不同位置发挥作用,最常用的是单向阀、安全阀、方向控制阀、
速度调节阀等。
http://www.diancifa.cc
2
http://www.diancifa.cc
3
http://www.diancifa.cc
4
http://www.diancifa.cc
5
http://www.diancifa.cc
6