Type C协会标准规范
- 格式:xlsx
- 大小:11.66 KB
- 文档页数:10
Group B-1 Type C connector
and cable assembly
mechanical tests協會標準
Cable pull out
線材吊重40 N Minmum, 線材組裝
需無電性斷開且線材不會
從CONN分離
Cable flex
線材柔軟No loss of continuity
during cycling
在循環操作時不會斷開
4-axis continuity四軸向No discontinuity
greater than 1 us
duration in any of the
four orientation
tested
在四個方向測試無大於
1us的瞬斷
Voltage Drop
壓降250mV for GND and
500mV for Vbus
Group B-2 USB2.0 and low
speed signal tests of Type
C cable and adaptor
assemblies
Type C-C
D+/D- pair attenuation
D+/D- 衰減≧-1.02dB@50MHz
≧-1.43dB@100MHz
≧-2.40dB@200MHz
≧-4.35dB@400MHz
D+/D- pair differential
impedance
D+/D- 衰減差75 ohms to 105 ohms
D+/D- pair Propagation
Delay
D+/D- pair 傳播延遲20 ns max
D+/D- intra-pair Skew
D+/D- 訊號對內的延遲差100 ps max
Coupling between CC and
differential USB D+/D-For cables the limit
is defined with the
vertices of (0.3MHz, -
60.5dB), (1MHz, -
50dB), (10MHz, -30dB),
(16MHz, -26dB), and
(100MHz, -26dB) in
scale of log10(f)
Coupling between VBus and
differential USB D+/D-≦-40dB for 0.3MHz
30MHz, and ≦
19.12log10(f/30)-40(in
dB) for 30MHz
100MHz
Single-ended coupling
between SBU_A and CC,
SBU_B and CCThe limit is defined
with the vertices of
(0.3MHz, -65dB),
(1MHz, -55dB), (18MHz,
-30dB), and (100MHz, -
26dB) in scale of
log10(f)
Single-ended coupling
between CC and D-For USB 2.0 Type C
cables, the singled-
ended couppling
between CC and D-
shall be below the
limits defined with
the vertices of
(0.3MHz, -48.5dB),
(1MHz, -38dB), (10MHz,
-18dB), and (100MHz, -
18dB) in scale of
log11(f)
For USB full featured
type C, the singled-
ended couppling
between CC and D-
shall be below the
limits defined with
the vertices of
(0.3MHz, -58dB),
(10MHz, -27.5dB),
(11.8MHz, -26dB), and
Single-ended coupling
between SBU_A and SBU_BThe limit is defined
with the vertices of
(0.3MHz, -56.5dB),
(1MHz, -46dB), (10MHz,
-26dB), (11.2MHz, -
25dB) and (100MHz, -25dB) in scale of
log10(f)
Single-ended coupling
between SBU_A/SBU_B and
differential USB D+/D-The limit is defined
with the vertices of
(0.3MHz, -80dB),
(30MHz, -40dB) and
(100MHz, -40dB) in
scale of log10(f)
Vbus loop inductance≦ 900 nH
Vbus capacitance8 nF to 500 nF in each
Type C plug
Inductance coupling factor
between Vbus and Other low
speed signal<= 0.3
Rd resistor verificationNA
Rp resistor verificationNA
Group B-3 USB super speed
signal tests of Type C
cable and adaptor
assemblies
Type C-C
Insertion loss Fit at
NyquistFor all USB 3.1 Gen2
super speed pairs:
≧-4 dB at 2.5 GHz
≧-6 dB at 5 GHz
≧-11 dB at 10 GHz
For all USB 3.1 Gen1
super speed pairs:
≧-7 dB at 2.5 GHz
≧-12 dB at 5 GHz
Integrated Muli-reflection
(IMR)≦0.126
ILfitatNq^2+3.024.
ILfitatNq-23.392, in
dB
Integrated crosstalk on
superspeed pairs (INEXT
and ISXT)Integrated near-end
crosstalk:
INEXT≦-40 dB to 12.5GHz, for TX1 to RX1,
TX2 to RX2, Tx2 to
RX1, TX1 to RX2, TX1
to TX2 and RX1 to RX2Integrated crosstalk
between superspeed pairs
and D+/D-
(IDDEXT_1NEXT+FEXT and,
IDDXT_2NEXT)Integrated near-end
crosstalk to D+/D-:
IDDXT_2NEXT≦-33 dB
Integrated near-end
and far-end crosstalk
to D+/D-:
IDDXT_1NEXT+FEXT≦-
34.5 dB
For all superspeed
pairs
Integrated Differential
crosstalk on D+/D- (IDDXT)NA
Integrated return loss
(IRL)≦0.046
ILfitatNq^2+1.812.
ILfitatNq-10.784, in
dB
Differential to common
mode conversion
(SCD12/SCD21)≦ -20dBfrom 100 MHz
to 10 GHz
Group B-4 USB Type C cable
assembly shielding
effectiveness
Type C-C
Cable shielding
effectivenessDifferential model:
≦-55 dB for f≦1.6
GHz
≦-50 dB for 1.6 GHz
≦f ≦ 4.0 GHz and for
5 GHz ≦f ≦6 GHz
Group B-5 Critical
Dimension
Type C-C
Critical DimensionAll dimensions for
component level
qualification and
overmold only for
cable and adaptor
assembles
EMC Shielding spring
inspectionNo EMC shielding
spring finger tip of
the USB full featuredtype C plug or USB 2.0
type C plug shall be
exposed in the plug
housing opening of the
unmated type C plug
Group B-7 Plug connector
wrenching test
Type C-C
Wrenching strengthThe plug shall be
mated with continuuity
test fixture after the
test forces have been
applied to verify no
damage has occurred
that causes
discontinuity or
shorting
ContinuityNo discontinuity or
shorts allowed
Dielectric withstanding
voltageNo disruptive dicharge
Wrenching strengthThe plug shall
disengage from the
test fixture or
mechanically fail,
when a moment of 2.0
Nm is applied in the
up and down direction,
and a moment 3.5 Nm is
applied in the left
and right direction