电站风机出力不足原因浅析摘要:通过对出力不足影响电站风机长期稳定运行的实际问题分析其原因,提出解决问题的具体措施。
关键词:出力不足;电站风机;稳定运行Analysis of the Reason of Output Shortage in Power Plant Fan Abstract: Output shortage is a common problem that effect the fan’s continued and stable operation in power plant. The root cause of output shortage is analyzed in this article through some practical problems, this article brings up the specific measures, and probably provides some ideas to solve this problem.0 引言0 the introduction风机是电厂的主要辅助设备之一,由于风机故障引起发电机组非计划停运和非计划降低出力运行造成的发电损失是巨大的,出力不足是影响电站风机长期稳定运行的常见问题。
通常我们遇到出力不足现象,都是认为风机出力不够,风机或电机选型偏小,而实际情况并非如此,造成风机出力不足的原因很复杂,如何找到风机出力不足的根本原因,从而彻底的解决问题,这是本文讨论的主要内容。
本文将通过理论研究和现场实例分析风机出力不足的根本原因。
Fan is one of the main auxiliary equipments of power plant, due to fan failure generating set not plan to stop works and the plan to reduce the output power loss is huge, is insufficient output capacity of common problem fan, long-term stable operation of the power station. Output shortage phenomenon, usually we met were thought the fan power is not enough, small fan or motor selection, and it's actually not the case, the causes of the insufficient fan output is very complex, how to find root cause of the fan power, so as to thoroughly solve the problem, it is discussed in this article the main content. This article through the theoretical research and field fan output less than the root cause of the case analysis.1 实例概述1 instance overview某电厂210MW工程火电机组670t/h锅炉配置2台冷一次风机,风机为单吸双支撑离心式通风机,设计参数见表1。
168试运中,风机调节门不能全开,在开度75%时电流已接近或超过额定电流,风机出力不足,不能安全稳定的满足机组210MW负荷要求。
210 mw thermal power unit engineering configuration two 670 t/h boilercooling fan, a fan for the single suction double support centrifugal ventilator, the design parameters are shown in table 1. Fan damper can not fully open, start-up in 168, 75% in the opening when the current is close to or more than the rated current, the fan power is insufficient, can't secure and stable to meet the requirements of 210 mw unit load.3 风机出力不足的类型及原因3 fan the types and reasons of the lack of power电站风机正常运行中出现出力不足主要表现有以下几个方面:(1)风机调节门尚未全开,电机已超电流;(2)风机调节门已全开仍不能满足系统出力要求。
而产生电站风机出力不足的问题可归纳为以下几个原因:Insufficient power the fan run normally appear in the output mainly has the following several aspects: (1) fan damper has not yet fully open, the motor has super current; (2) fan damper has been fully open still can not meet the requirement of the system output. Fan the problem of insufficient output produced by power stations can be summarized as the following reasons:风机设计原因。
风机设计参数较小,实际运行参数远大于风机设计参数,以至于风机无法满足机组负荷。
Fan design. Smaller fan design parameters, operation parameters is greater than the fan design, so that the fan is unable to meet the load.风机选型原因。
风机出现出力不足,首先都会想到选型问题,如运行点与设计点偏离较大,风机运行效率低下等都会引起风机出力不足。
Fan type selection. Fan power is insufficient, will be thinking of first selection problems, such as the operating point deviates from design point is larger, the fan running and low efficiency, and other fan output deficiency will cause.风机制造原因。
叶片型线特别是机翼形叶片的型线对风机出力、效率等影响较大。
制造不当或者运行磨损等都会不同程度破坏叶片型线,导致出力和效率的下降。
Fan manufacture. Blade type line especially the wing shape of the blade type line of fan had a greater influence on the output, efficiency, etc. Manufacturing or improper operation and wear will destroy the bladetype line, different level led to a decline in output and efficiency.风机安装原因。
调节门的反装及过大的配合间隙会导致风机性能大为降低,如离心风机集流器与叶轮的径向间隙、轴流风机叶轮与机壳的径向间隙等[1] 。
Fan installed. Damper's excessive and fit clearance will lead to the fan performance is greatly reduced, such as current collector and the impeller of the centrifugal fan of radial clearance, axial flow fan impeller and casing radial clearance, etc. [1].系统原因。
系统管道布置不合理会直接影响风机的性能。
同时由于风机是系统的一个部件,风机与系统直接存在着的相互作用可能使风机在远离其设计和规定的工况下运行,系统中其它设备运行的正常与否也会影响到风机的性能[1] ,如空预器漏风及堵塞、暖风器堵塞、烟道积灰、脱硫系统GGH堵塞、除雾器堵塞等常见问题都会造成风机出力不足。
System. System piping is ignored a direct impact on the performance of the fan. Because the fan is a component of the system at the same time, the air blower and the system exist interaction may make the fan directlyaway from the design and the conditions stipulated in the operation, other devices in the system running is normal or not will affect the performance of the fan [1], such as air preheater leakage and blockage, warm wind machine, jams, flue dust desulfurization systems GGH plug, demister blocked fan output less than common problems will be caused.运行原因。
燃烧煤质较设计煤质相差较大。