车库门管状电机安装介绍
- 格式:doc
- 大小:175.50 KB
- 文档页数:6
服务培训手册概述 (2)特点 (3)规格 (4)导轨表 (5)安装 (6)开门机逻辑(设计)...................................................................................................................................... 7-8接收机/控制模块 (9)力马“智能”接收机 (10)遥控器特点 (11)遥控器型号 (11)把接收机编程到遥控器上 (12)编程无钥匙进入系统 (13)多功能壁装式门控板.................................................................................................................................. 14-15连接 (16)自动设置极限 (17)手动设置极限 (18)行程设置 (19)设置力 (20)自动反向系统(安全) (21)防护系统™(红外传感器) (22)故障排除-防护系统™(红外传感器) (23)设置张力 (23)遥控测试设备M18E (24)电动机和传动装置 (25)电动机的安装/拆卸(电动机更换) (26)故障排除/故障纠正..................................................................................................................................... 27-30力马服务 (31)1型号特点LM600A LM800A LM1000A标称拉力600牛顿800牛顿1000牛顿开门机型号皮带/链条皮带/链条皮带/链条电子限位开关是是是“智能”接收机是是是无线电频率433.92MHz 滚动代码433.92MHz 滚动代码433.92MHz 滚动代码遥控器的数量(作为标准件1 1 2提供)多功能门控板附件标准/78LM 标准/98LM带灯门控按钮是否否最大行程定时器是是是无钥匙进入系统附件附件附件防护系统附件附件附件™(红外传感器)*照明230V/40W 230V/40W 230V/40W照明周期持续时间 1.5 -4.5 分钟 1.5-4.5 分钟 1.5-4.5 分钟快速接线端子否是否导轨型号C型导轨30毫米C型导轨30毫米C型导轨30毫米导轨长度 3.0米以下 3.0米以下 3.0米以下门最大宽度 5.0米 5.0米 5.0米门最大重量90千克110千克130千克软启动/软停机是是是整机保修期1年1年1年* 视有关型号而定21. 力马开门机与平滑运行的软启动/软停机机构配合工作。
S M A N U As of date of manufacture, meets all ANSI/UL 325 Safety Requirements for Vehicular Garage Door OpenersM A N U A L C A R E F U L L Y B E F O R E I N S T A L A T I O N O R INSTALLER: Place this manual in the plastic envelope provided andpermanently attach to the wall near the pushbutton.Product Features....................................................2 Tools Required/Component Identification.....2 & 3 Assembly Instructions...........................................3 Identify Your Door Type.........................................4 Important Installation Instructions........................5 Installing the Opener..............................................6 Mounting the Front Bracket............................6 Mounting the Power Head...............................7 Using the Manual Release Mechanism...........7 Installation......................................8 Requirements/Permanent Wiring........9 Control and Auxiliary Equipment........................10 Standard Wall Push Button Installation.......10 Installation of the Super Station...................10 Remote Control Radio System .....................11 TABLE OF CONTENTSOR DEATH. Gives instructions to avoid FCC and IC Radio Operation Statement ......12 Installation of Safe Finish Photosystem.......13 Installation Checklist.....................................14 Operation and Adjustment Instructions............15 Important Safety Instructions.......................15 Basic Operating Parameters.........................15 Testing the Limit Settings.............................16 Testing the Sensitivity...................................16 Testing the Reversing System......................16 Testing the Safe Finish Photosystem...........17 Operating the Super Station Wall Station Wiring Diagram.....................................................18 Auxiliary Equipment Wiring Diagram..................19 Troubleshooting Guide........................................19 Warranty Statement. (20)CAUTION READ THESE STATEMENTS CAREFULLY AND FOLLOW THE INSTRUCTIONS CLOSELY The Warning and Caution boxes throughout this manual are there to protect you and your equipment.Pay close attention to these boxes as you follow the manual.WARNING CAUTION Indicates an ELECTRICAL hazard of DAMAGE to the door, door opener, or equipment. Gives instructions to avoid thehazard .Indicates an ELECTRICAL hazard of INJURY OR DEATH. Gives instructions to avoid the hazard . Indicates a MECHANICAL hazard of DAMAGE to the door, door opener, or equipment. Gives instructions to avoid the hazard . Residential Vehicular Garage Door OperatorMODELS: MVP and MVP-SQSTEPLADDER TAPE MEASUREWOOD BLOCKHAMMERHACKSAW TOOLS REQUIRED FOR INSTALLATION1/2” OPEN ENDWRENCHLEVELSCREW DRIVERSMALL SCREW DRIVER (1/8” HEAD)NOTE:Rail/Chain Assembly is packaged separately from the Power Unit. The Inner Trolley half, Front Idler Sprocket, Chain, and Limit Cams are assembled on the Tee Rail at the factory.Follow the steps outlined below to complete assembly prior to installation. Refer to the component identification illustrations on the previous page.STEP 1: Protect the Power Unit cover fromscratching during assembly by placing it on cardboard. Remove the two 5/16"-18 washered nuts and save them for later use. STEP 2: Position the Tee Rail/Chain Assembly box near the Power Unit. Open the box and locate theInstallation Hardware Packet.STEP 3: Locate the Outer Trolley half (packaged 104363ASSEMBLY INSTRUCTIONSDOOR MOUNTINGFRONT IDLERTROLLEY OUTER CHAIN GUARDWALL MOUNTING BRACKETRELEASE ROPE AND KNOBOPENER HARDWAREBAGTEE RAILRUBBER BUMPEROPENER HEAD UNITPHOTOSYSTEM HARDWARERADIO TRANSMITTERCONTROL WIRESPOOLIMPORTANT!IDENTIFY YOUR DOOR TYPE FROM THOSE ILLUSTRATED BELOW ANDFOLLOW INSTRUCTIONS FOR THAT TYPE OF DOORFOR THESE TYPES OF DOORS USE MODEL MVP OR MODEL MVP-SB. USE 7 FT, 8 FT OR 10 FT RAIL (MATCH DOOR HEIGHT)THE MODEL MVP SERIES IN NOT DESIGNED TO OPERATE THESETYPES OF DOORSone 5/16"-18 washered nut (supplied) Tighten the bolt a MAXIMUM of 1.5 turns after the bolt and nut are Recheck the nuts used to secure the TeeRail to the Power Unit, making sure they are tight. the Chain tension, Chain twist, Chain Guard and the position of both the Close Limit Switch and Open Limit Switch Actuators.CHAIN GUARDACTUATORSPROCKETSPROCKET 104366Assembly is now complete and you are ready to begin installation of the opener.CHAINMASTER LINKOUTER NUTINNER NUTMASTER LINKCHAINDOOR TYPE IDENTIFICATIONONE PIECE DOOR NO TRACKJAMB HARDWAREONE PIECE DOOR NO TRACKPIVOT HARDWAREHIGH ARC OF DOOR TRAVELHIGH ARC OF DOOR TRAVELDOORPIVOT104368TRACKTRACKDOORDOOR104367SECTIONAL DOOR CURVED TRACKONE PIECE DOOR HORIZONTAL TRACK JAMB HARDWAREHIGH ARC OF DOOR TRAVELHIGH ARC OF DOOR TRAVELPower Unit on a ladder or other sturdy support.Open the door to the full open position. Allowsection of the door (as shown in the illustration104372Step 8: Connecting the Door Arm to the Door Type 1: Door Mounted BracketVisually align the door arm connecting hole with the middle hole of the door bracket by rotating the tube section in the appropriate direction.Release the trolley (leave door arm attached) with the manual release cord and pull trolley toward the power head unit. Now rotate the door arm tube section two turns counterclockwise (increasing the exposed length of the door rod) to provide a cushion when the door is closed or encounters an obstruction. Align connecting hole in the door arm to middle hole in the door bracket; insert 3/8” diameter bolt and tighten locking nut, allowing for free pivot of the arm. Note: Do not overtighten locking nut as this will cause binding between the door arm and door bracket.Type 2: Strut Mounted BracketVisually align the door arm connecting hole with the connecting pin of the strut by rotating the tube section in the appropriate direction.Release the trolley (leave door arm attached) with the manual release cord and pull trolley toward the power head unit. Now rotate the door arm tube section two turns counter-clockwise (increasing the exposed length of the door rod) to provide a cushion when the door is closed or encounters an obstruction. Align connecting hole in the door arm with the strut mounted connecting bracket. Insert connecting pin through the hole in the door arm. Secure the connecting pin to the strut bracket according to the manufacturer’s instructions. Note: Door Bracket Mount or Strut Mount - If rod bottoms in cushion tube, cut rod to allow for proper function of this assembly. Set the outer trolley to re-engage, see page 7.Alternate StrutConnecting BracketCut to Fit110054-2Openers are subject to vibration during normal operation which may shorten their life spans.Rough Service bulbs, available at most hardware stores, are recommended. Fit Light Diffuser tabs into the panel slots as shown.On most models, theLimit Cams are installed at the factory. If the Limit Cams have not been installed, or it is necessary to move a Limit Cam to a different link, fasten them to the chain as shown at right in the approximate positions as illustrated below. Position theSwitch Actuators as shown below.104380106428FASTENING LIMIT CAM TOCHAINunder “Special Notes” at the While the LED is. The .LED will blink twice to confirm a valid code and Special Notes - Express CodingRepeat the steps listed above as needed or desired for each button. Each button can be programmed to a unique code, however all three buttons may be programmed at one time (Express Coding). To Express Code, select the “+” button in Step 2, then end the code entry in Step 3 with the “+” button (the first 8 entries can be any random code). The code for each button may be changed at any time.However, if the plus button is programmed as described above, it will replace the existing code settings of the zeroStep 1Step 2Step 3used, slide it into the recess provided on the back of the transmitter caseuntil the snaps on the caseHomeLink® is a registered trade mark of Johnson Controls, Inc. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept anyPRE-POWER ON-INSTALLATION CHECKLISTBefore continuing with the operation andadjustment section, make sure that:1. The front and rear mounts for the opener aresound and secure and the rail is positionedcorrectly above the high arc of the door, and thatthe opener is positioned over the door actioncenterline.2. For sectional door and one piece door withtracks, the position of the door arm (with thedoor closed), is such that it’s connecting point onthe trolley is 5” to 8” behind it’s connectingpoint on the door bracket. The door arm shouldnever be perfectly vertical when the door in inthe closed position.3. The Manual Release Label and cord are secureto the Manual Release Lever. The handle islocated 6 FT above floor level and requires nomore than a 50 pound pull to activate. Thetrolley and the release mechanism are properlylubricated.4. The standard wall push button or the SuperStation (deluxe wall push button station) is insuch a position and of such a height that it canonly be actuated by an adult of average height.The Control Button Warning label isprominently displayed next to the push button orwall station.5. All wiring is correct to codes or better. There isground continuity form the supply. The groundprong on the power cord is intact.6. All ropes have been removed from the door.The door moves freely without binding whenraised or lowered manually. The door iscorrectly balanced and lubricated. All doorhardware is secure and sound. The sensitivityhas been adjusted to minimum force for theapplication.7. The door reverses on obstructions to within 1.5"of the floor. The concrete or other surfacebeneath the closed door provided uniformcontact.8. The plastic envelope for this manual is attachedto the wall near the push button or wall stationand this manual is placed there for owner useand reference.9. On door with extension type counterbalancesprings, restraint cables have been placedthrough the springs.10. There is Ground Fault Interruption (GFI)protection of the power line to the opener or inthe receptacle.11. On doors with adjustable bottom edges, edgeshave been locked after adjustment.TURNING ON POWER TO THE OPENERNOTE: It is now necessary to turn on the power in order to run the opener to test the operation and check the limit settings. Before doing so, ensure that all mounting hardware is installed and has been properly tightened, that all electrical connections are per local code requirements, and that proper wiring practices have been followed. Also, double-check that all ropes have been removed from the door and that the doorway is clear.BASIC OPERATING PARAMETERS Please note the following Operating Parameters which apply to Openers with Auxiliary Entrapment Protection System (Safe Finish™ Photosystem, Installation Instructions on Page 15) and a standard wall push button connected. Please see page 17 for instructions concerning the Super Station Deluxe Wall Push Button operating parameters.IF THE DOOR IS…...FULLY OPEN, then pushing the standard wall Push Button or the radio control will cause the door to begin MOVING DOWNWARD. ...FULLY CLOSED, then pushing the wall Push Button or the radio control will cause the door to begin MOVING UPWARD....MOVING UPWARD, then pushing the wall Push Button will cause the door to STOP. The next push of the wall button will cause the door to begin MOVING DOWNWARD (Alternate Action Operation)....MOVING UPWARD, then pushing the radio control will cause the door to STOP. The next push of the wall button will cause the door to RESUME UPWARD MOVEMENT (Radio Operation). ...MOVING DOWNWARD, then pushing the wall Push Button or the radio control will cause the door to STOP, PAUSE FOR APPROXIMATELY ONE SECOND, AND THEN BEGIN MOVING UPWARD....MOVING DOWNWARD then reaches the down limit, the lamp will blink off for a 1/2 second then turn back on again, remaining on for 4 minutes 30 seconds and will then automatically turn off....MOVING UPWARD then reaches the open limit, the lamp will remain on for 4 minutes 30 seconds and will then automatically turn off.STEP 3: Testing the Sensitivity Force — To test theSensitivity System, start the Opener and grasp the bottom door handle halfway through the door's travel(opening or closing). When testing in the CLOSEdirection, a second person will be needed to maintainpressure on the Push Button IF an Auxiliary EntrapmentProtection Device has not yet been fitted. If a secondperson isunavailable, use astiff cardboard carton placed in the door's downward path to indicate the force the Opener isOPEN FORCEADJUSTMENTCLOSE FORCE ADJUSTMENT104391THE SENSITIVITY SYSTEM REVERSING TESTENSURE THAT THIS IMPORTANT SYSTEMW A R N I N G1 2 3 4 5 6 7 8 9 Plus Button Zero Button Minus ButtonIF DESIRED, RECORD YOUR RADIO TRANSMITTER CODE POSITIONSETTINGS HERESee Page 11 for Radio System programming instructions and FCC/RSS-210 Industry Canada statement. The opener radio system is HomeLink® compatible.Serial #: Date Installed: Your Dealer:This garage door operatorcomplies with all requirements ofANSI/UL Standard 325.P/N 190-111069 Rev. FX1 August 2007Copyright © 2007 Linear LLC。
电动门控制器的安装调试手册一、前言电动门控制器是一种广泛应用于自动门系统中的设备,它能够实现对电动门的控制、监控和保护等功能。
本手册将详细介绍电动门控制器的安装和调试步骤,帮助用户正确使用电动门控制器,并确保其正常运行。
二、安装准备1. 确保所需要的电动门控制器和配件齐全,并检查其是否完好无损。
2. 确定安装位置,并确保该位置适合安装电动门控制器。
3. 关闭电源,并确保操作安全。
三、安装步骤1. 安装控制器面板:将控制器面板固定在预定位置上,并使用螺丝固定好。
2. 连接电源线:将电源线连接到控制器,并进行必要的接地处理,确保电气安全。
3. 连接电动门设备:根据电动门设备的接线图,将电动门设备连接到控制器上,并确保连接牢固可靠。
4. 连接其他外部设备(如传感器、遥控器等):根据需要,将其他外部设备连接到控制器上,并进行相应的设置。
5. 检查连接:检查所有连接是否正确,确保无误后进行下一步操作。
四、调试步骤1. 接通电源:将电源线接通,并确保电流稳定。
2. 启动控制器:按下控制器上的启动按钮,并观察控制器面板上的指示灯是否正常亮起。
3. 调整参数设置:根据实际要求,对控制器进行相应的参数设置,包括开门速度、关门力度等。
4. 检查门的运行状态:通过遥控器或其他操作方式,测试门的开关、停止等功能,观察门的运行状态是否正常。
5. 依次测试其他功能:对控制器的其他功能(如反向、门磁感应等)进行测试,确保各功能正常可用。
6. 调试完成:经过以上步骤的检查和测试后,确认控制器的各项功能正常可用,调试工作完成。
五、注意事项1. 本手册中的安装调试步骤仅供参考,请根据实际情况进行调整。
2. 安装和调试过程中需谨慎操作,注意安全。
3. 如遇到问题,请及时咨询专业人士或厂家技术支持。
4. 严禁私自拆解或改动控制器内部零部件,以免损坏设备或导致安全事故。
六、结语通过本安装调试手册,您可以了解电动门控制器的安装和调试方法,帮助您正确使用电动门控制器,确保其正常运行。
1、管状电机概述管状电机是本公司引进国外先进技术,自行研制开发的最新产品。
它主要由电机、刹车、减速和行程限位四部分组成,可以广泛应用于遮阳帘(蓬),电动屏幕,卷帘门,金属防盗门,车库门等。
2、管状电机的优良性能体现在:a、体积小,重量轻,噪音极小,隐蔽性强;b、稳定,耐用的机械行程限位确保电机行程常年准确c、设有热敏保护器,当电机连续工作,温度超过规定(150度)时,电机将停止运转;当电机温度降低(约15分钟后),又恢复正常工作状态;d、外形设计精巧,操作简单,安装方便;e、绝缘等级为F级。
3、产品安装A、电机与传动轴装配a、将皇冠轮与驱动轮装入电机确定位置,皇冠轮凹槽与内齿套凸条啮和紧密,驱动轮用卡簧卡好;b、将电机插入转动轴中,皇冠轮应与传动轴对端紧配合,若采用圆轴,必须用螺丝或者拉铆钉固定,注意皇冠轮固定螺丝一定不能打入内齿套。
c、将尾塞插入传动轴的另一端,并且固定牢固。
B、现场施工a、安装前必须作水平和垂直测试;b、先将小支架固定在端板上,再将端板和轨道固定在墙上,须保证与墙面连接牢固;c、安装传动轴于两端的小支架上,须保证传动轴两端水平,门窗两侧与传动轴保持垂直;d、传动轴与小支架间用开口销固定。
C、门窗帘片和传动轴装配a、接好电源,把电机转动到另一端停止状态(指门窗安装后的关闭状态)后,切断电源;b、将加工好的帘片从传动轴的上方放入轨道中,完毕后门窗应处于关闭状态;c、固定帘片和传动轴:先确定螺丝的固定位置,应沿传动轴均匀分布,并保证整体帘片在固定后不能有卷曲;传动轴电机端固定螺丝的长度,应保证不损伤电机的外壳(间隙不小于5mm);d、帘片与传动轴固定后,应检查连接是否牢靠,受力是否平衡;D、电机调试a、接通电源后,在前面门窗关闭情况下,让其上升,按调节限位标签所示(←→)表示电机的正反转,即驱动轮的转动方向。
目前转动的方向(箭头所指方向)为上限位控制旋钮,若行程需要加长,将调节杆往“+”号方向旋转;若行程需要减短,将调节杆往“-”号方向旋转。
一、钢架的安装用标准规格的钢架立于洞口的两侧,保证钢架的垂直度和水平度,然后用10个M10×110㎜的膨胀螺栓固定到墙壁上,保证每个点能承受1000N的垂直拉力而不脱落、不松动,并注意避开轨道固定件的安装位置。
二、轨道的安装根据门板的宽度和高度确定两轨道固定件的位置并用水平管测水平,再用M8×41㎜的方头螺钉固定。
用卷尺测准水平轨与墙壁及两水平轨之间的间距,用水平尺测准水平轨的水平,然后用M6.4×14㎜的小帽螺丝和六角螺帽将水平轨连接件与水平轨和轨道固定件连接固定。
用带眼角钢制成两个三角架,然后将其与水平轨的末端用M6.4×14㎜的小帽螺丝、螺帽连接,并用M8×70㎜的膨胀螺栓固定到天棚或墙壁上。
三、扭簧的安装将扭簧中心支架、尼龙胶圈、固定法兰、与门体重量相匹配的扭簧、锁紧法兰、绕线轮、轴承支架按顺序(分清左右侧)套在镀锌钢管上,并注意各零部件是否安装正确。
用M8×41㎜的方头螺钉将扭簧中心支架固定到洞口上部中间位置的短木板上,并注意避开链盒的安装位置。
用M8×40㎜的螺栓将扭簧中心支架、尼龙胶圈、固定法兰和扭簧连接,再将扭簧和锁紧法兰连接。
然后将轴承支架的下端用M9.5×19㎜的大帽螺丝和螺帽与水平轨连接件连接固定,轴承支架的上端用M8×41㎜的方头螺钉固定到侧木框上。
四、门板的安装将底密封条放到底门板的底部,并用M4×16㎜或M6.4×16㎜的自攻钉将其从背面固定到门板上。
将底轮支架放到门板的两侧*近底密封条的位置,1#折页分别放到门板顶部的左中右三个位置上(宽度低于10英尺,中间位置是一个;宽度在10英尺至14英尺,中间位置是二个;宽度在15英尺至18英尺,中间位置是三个),并分别用M6.4×16㎜的自攻钉固定。
然后将滚轮涂上甘油穿入底轮支架和1#折页中,将此门板放到立好的轨道里并使其水平。
中文中文D1000车库门电机目 录关于安装和维护的通用安全介绍 P2工具和材料 P2CE认证声明 P3对安装者的警示 P31 外型尺寸 P42 技术参数 P43 辅助电子设备 P44 系统图示 P55 预先检查 P56 安装 P66.1 滑动导轨 P66.2 后部固定器 P66.3 外部释放器(可选) P77 安装 P77.1 滑动导轨 P77.2 门上固定 P87.3 控制器 P97.4 释放自动系统 P97.5 外部释放 P98 E1000控制板 P108.1 技术参数 P108.2 E1000控制板元件列表 P108.3 接口端 P108.4 DS1编程拨动开关 P108.5操作逻辑模式 P109 迎接灯 P1110 接口端 P1111编程 P1211.1 电控板设置 P1211.2 学习 P1211.3 预闪 P1312 无线遥控编码的存储 P1412.1 存储DS无线遥控代码 P1412.2 存储SLH无线遥控代码 P1412.3 存储LC无线遥控代码(仅用于部分市场) P1412.3.1 遥控存储LC无线遥控代码 P1512.4 遥控器删除步骤 P1513 开始 P1514 延长电线 P1515 维护 P1516 维修 P1517 附件 P1617.1 中央支架 P1617.2 用钥匙的释放装置 P1617.3 安全充气边缘CN60E P1617.4 电池组件 P16•关于安装和维护的通用安全介绍 工具和材料重要!挤撞危险。
在你开始安装前仔细地阅读完整的安装手册。
不要作任何本手册未提到的改动。
对于一个安全实用的自动门,需要正确地遵守安装步骤和使用说明。
不正确地安装和使用会引起严重的人员和财产不要将本控制器安装用于所指定的以外的用途。
为了紧固,使用所提供的附件或者,无论如何,紧固系统(螺丝,膨胀螺栓,等等)适合于固定的种类和自动系统的机械紧固件。
检查装配门是否符合EN12604 和EN12605 标准(相关信息可以从门本身的文件中找到)。
管状电动卷闸门安装方法及步骤1. 准备工作首先,咱们得知道,安装管状电动卷闸门可不是一件轻松的事儿,尤其是对于没有经验的小伙伴来说。
不过别担心,今天咱就来聊聊怎么一步一步把这个门装上去,让你在邻居面前好好显摆一番。
开始之前,先得准备好工具和材料。
一般来说,你需要卷闸门本体、电机、轨道、控制器、螺丝刀、扳手,还有安全保护设备。
哦对了,千万别忘了安全第一,安装的时候一定要戴好手套和护目镜,别让自己变成“装门的倒霉蛋”!2. 安装步骤2.1 确定安装位置好了,准备工作搞定后,咱们就可以开始啦。
第一步,选择一个合适的安装位置。
这个位置可得仔细选,不仅要考虑美观,还得考虑到日常使用的方便性。
一般来说,门口要留出足够的空间,以免开关门的时候“左邻右舍”都被惊吓到。
而且,还得看看地面是否平整,毕竟谁也不想开个门像坐过山车一样。
2.2 安装轨道接下来,咱们要开始安装轨道啦。
这一步可得小心点,轨道的安装直接影响到后续的顺畅程度。
首先,按照说明书把轨道放到预定的位置上,用水平尺检查一下,确保它是水平的。
如果不平,可能会导致卷闸门在滑动的时候“跑偏”,那就麻烦了。
接着,用螺丝把轨道固定好,这里可得用点力气,确保它稳稳当当。
2.3 安装卷闸门然后就是把卷闸门本体安装上去。
这一步,通常得找个人帮忙,毕竟门可不轻,尤其是大门,更是需要两个人合力才能搞定。
将卷闸门的一侧挂到轨道上,然后慢慢放下另一侧,确保它能顺利地在轨道上滑动。
哎呀,这可真像在玩一场“解谜游戏”,一点点把每个部分都拼凑好。
3. 电机与控制器的安装3.1 安装电机咱们的卷闸门总得有动力,电机可不能少!找个合适的位置把电机固定好,通常是安装在门的上方或者一侧。
接下来,连接电机和卷闸门的链条,确保连接牢固。
这里可以用一些小技巧,比如轻轻拉动链条,确保它不是太紧也不是太松,就像穿鞋子一样,舒适最重要。
3.2 连接控制器最后,咱们要连接控制器了。
将控制器固定在墙上,确保在使用的时候方便操作。
1、管状电机概述管状电机就是本公司引进国外先进技术,自行研制开发得最新产品、它主要由电机、刹车、减速与行程限位四部分组成,可以广泛应用于遮阳帘(蓬),电动屏幕,卷帘门,金属防盗门,车库门等。
2、管状电机得优良性能体现在:a、体积小,重量轻,噪音极小,隐蔽性强;b、稳定,耐用得机械行程限位确保电机行程常年准确c、设有热敏保护器,当电机连续工作,温度超过规定(150度)时,电机将停止运转;当电机温度降低(约15分钟后),又恢复正常工作状态;d、外形设计精巧,操作简单,安装方便;e、绝缘等级为F级。
3、产品安装A、电机与传动轴装配a、将皇冠轮与驱动轮装入电机确定位置,皇冠轮凹槽与内齿套凸条啮与紧密,驱动轮用卡簧卡好;b、将电机插入转动轴中,皇冠轮应与传动轴对端紧配合,若采用圆轴,必须用螺丝或者拉铆钉固定,注意皇冠轮固定螺丝一定不能打入内齿套。
c、将尾塞插入传动轴得另一端,并且固定牢固。
B、现场施工a、安装前必须作水平与垂直测试;b、先将小支架固定在端板上,再将端板与轨道固定在墙上,须保证与墙面连接牢固;c、安装传动轴于两端得小支架上,须保证传动轴两端水平,门窗两侧与传动轴保持垂直;d、传动轴与小支架间用开口销固定。
C、门窗帘片与传动轴装配a、接好电源,把电机转动到另一端停止状态(指门窗安装后得关闭状态)后,切断电源;b、将加工好得帘片从传动轴得上方放入轨道中,完毕后门窗应处于关闭状态;c、固定帘片与传动轴:先确定螺丝得固定位置,应沿传动轴均匀分布,并保证整体帘片在固定后不能有卷曲;传动轴电机端固定螺丝得长度,应保证不损伤电机得外壳(间隙不小于5mm);d、帘片与传动轴固定后,应检查连接就是否牢靠,受力就是否平衡; D、电机调试a、接通电源后,在前面门窗关闭情况下,让其上升,按调节限位标签所示(←→)表示电机得正反转,即驱动轮得转动方向。
目前转动得方向(箭头所指方向)为上限位控制旋钮,若行程需要加长,将调节杆往“+”号方向旋转;若行程需要减短,将调节杆往“—”号方向旋转。
别墅车库保温卷帘门技术标准1、验收标准建筑装饰装修工程质量验收规范《GB50210-2002》钢质防火门、防火卷帘门图集《88J13-4》GB14102-93《防火卷帘通用技术条件》2、保修期:2年3、产品性能及参照标准GB 191 包装储运图示标志 GB 699优质碳素结构钢技术条件GB 700 碳素结构钢 GB 9493 灰铁铸件GB 1243.1 传动用短节距精密滚子链 GB 2518 连续热镀锌薄钢板和钢带GB 5824 建筑门窗洞口尺寸系列 GB 6388 运输包装收发货标志GB 7633 门和卷帘的耐火试验方法 GB14102-93 防火卷帘通用技术条件GB/T9978—1999 建筑构件耐火实验方法4. 根据现场的实际洞口尺寸,结合图纸进行深化设计,做到准确无误。
5.卷帘门的封堵(侧装和中装)应符合88J13-4中P81、82中相应要求。
6.车库门内侧钢板厚度≥0.376mm,外侧静音压型钢板厚度≥0.376mm,门板厚度≥20mm,轨道壁厚≥1.5mm,内置聚氨酯发泡胶,门板内外层均采用镀锌钢板,75型门板,深咖啡色(RAL-8017)。
7.开门机:电机采用140N新型管状电动机带扭簧(具有离合功能),厂家按单樘门的重量合理配置电机,并在报价说明中予以明确。
每樘车库门配置2个遥控器,通过遥控器操作门体自动运行作用距离大于20m。
技术参数:适用电压220V,运行速度不小于12m/min;门扇质量小于70kg,手动启闭力应小于70N,门扇质量大于70kg,手动启闭力应小于120N。
8.开启方式:遥控、电动兼手动(静音卷帘)。
9. 安装标准9.1左右支架宽度万向固定位置线划线后依据卷帘门安装图,对所划线位置进行检验验证其精度允差不大于3mm。
左右二支架轴头(轴承)中心应同轴,其不同轴度在全长范围内不大于2mm。
9.2卷筒轴的安装后应检验确认其水平度,水平度在全长范围内不大于2mm。
9.3开闭机运转状态不应有异声,停机制动灵敏、可靠。
1、管状电机概述
管状电机是本公司引进国外先进技术,自行研制开发的最新产品。
它主要由电机、刹车、减速和行程限位四部分组成,可以广泛应用于遮阳帘(蓬),电动屏幕,卷帘门,金属防盗门,车库门等。
2、管状电机的优良性能体现在:
a、体积小,重量轻,噪音极小,隐蔽性强;
b、稳定,耐用的机械行程限位确保电机行程常年准确
c、设有热敏保护器,当电机连续工作,温度超过规定(150度)时,电机将停止运转;当电机温度降低(约15分钟后),又恢复正常工作状态;
d、外形设计精巧,操作简单,安装方便;
e、绝缘等级为F级。
3、产品安装
A、电机与传动轴装配
a、将皇冠轮与驱动轮装入电机确定位置,皇冠轮凹槽与内齿套凸条啮和紧密,驱动轮用卡簧卡好;
b、将电机插入转动轴中,皇冠轮应与传动轴对端紧配合,若采用圆轴,必须用螺丝或者拉铆钉固定,注意皇冠轮固定螺丝一定不能打入内齿套。
c、将尾塞插入传动轴的另一端,并且固定牢固。
B、现场施工
a、安装前必须作水平和垂直测试;
b、先将小支架固定在端板上,再将端板和轨道固定在墙上,须保证与墙面连接牢固;
c、安装传动轴于两端的小支架上,须保证传动轴两端水平,门窗两侧与传动轴保持垂直;
d、传动轴与小支架间用开口销固定。
C、门窗帘片和传动轴装配
a、接好电源,把电机转动到另一端停止状态(指门窗安装后的关闭状态)后,切断电源;
b、将加工好的帘片从传动轴的上方放入轨道中,完毕后门窗应处于关闭状态;
c、固定帘片和传动轴:先确定螺丝的固定位置,应沿传动轴均匀分布,并保证整体帘片在固定后不能有卷曲;传动轴电机端固定螺丝的长度,应保证不损伤电机的外壳(间隙不小于5mm);
d、帘片与传动轴固定后,应检查连接是否牢靠,受力是否平衡;
D、电机调试
a、接通电源后,在前面门窗关闭情况下,让其上升,按调节限位标签所示(←→)表示电机的正反转,即驱动轮的转动方向。
目前转动的方向(箭头所指方向)为上限位控制旋钮,若行程需要加长,将调节杆往“+”号方向旋转;若行程需要减短,将调节杆往“-”号方向旋转。
另一个限位的调节方法与此相同,直到用户所需要的位置为止。
b、调整限位时,一定要按着标签所示的规定进行操作,且最好是电机运转过程中进行,停机时严禁随意调节行程长短,否则可能损坏电机限位。
4、安全注意事项
a、管状电机的安装与维护应由专业的技术人员实施;
b、电机在安装之前应检查电机在运输的过程中有无变形、损坏,附件是否齐全;
c、电机是用插座应配有地线插孔,并可靠接地;
d、与遥控器配套使用时,请严格按照上升←→停止←→下降原则(在上升和下降的相互转换过程中,应按停止键一次,切忌上升←→下降直接切换),正常使用可以延长电机的使用寿命;
e、电机安装前,应先进行空载测试,正反均可以运转且运转工程中不应有异常声音。
5、普通卷帘门安装说明
a、安装时候电机部分应在右面,扭簧部分在左面,人站在室内向外看,这种电机叫右开式电机,扭簧叫左扭簧,反之,叫做左开式电机,右扭簧。
b、门片安装前先测量门片卷在轴管、或者轴套上的圈数,扭簧顶紧圈等于门片包住卷轴、或者轴套的圈数加上2-3圈。
假设扭簧的圈数为N,启动电机,使轴管关门方向转动N圈左右,转动过程中如果发现电机停止,请将关门限位调节杆向(+)反方向旋转,既可以达到你所需要安装的位置。
c、轴管调整到位后,将门片用螺丝固定在铁管上。
确认连接牢固。
此时通过上下行程调节杆可以把门的上下位置固定,注意:进行门的下行程调整时只要门的座条(底梁)碰到地面即可,不需要把门片压得太紧。
以免打开离合时引起不便
d、通过离合锁将离合机构分离后,可使用人力将门拉起,或关闭;若门向上太重,向下太轻,说明轴管内扭簧回转力不够,此时将门片全部卷起捆住向关门的方向转一圈,再将门片旋转轨道,然后再进行调试。
反之,若门向下太重,而向上太轻,说明轴管内扭簧回转力已过头,此时将门片全部卷起捆住向开门的方向转一圈,再将门片放置轨道,然后再进行调试。
e、安装过程中请严格按照正反方向安装,否则扭簧发生变形,变粗损坏,导致不能使用。
f、安装前铁管外壁最好单行对打两排螺丝孔,这样便于扭簧在安装时进行调整。
g、注意:门片尚未固定在轴管上时,手拉离合机构不能分离。
一旦分离,会使轴管突然向开门方向转动,会导致人员受伤以及手拉机构等其它部件损坏,需让门片固定住轴管后,门片重量平衡一部分扭簧的提升力后,才能分离离合机构。
6、常见的故障和排除。