MC3361_中文资料
- 格式:pdf
- 大小:142.92 KB
- 文档页数:5


MC34167 MC331671简介该MC34167, MC33167系列单片电源开关可用于dc–to–dc优化调节器申请.这些器件的固定频率,电压模式稳压器包含了所有的积极作用需要直接和实施step–down以最小的转换数量voltage–inverting外部元件.它们也可以用于成本效益在step–up转换器应用.潜在市场包括汽车,计算机,工业和成本敏感的消费产品.每一个设备的部分介绍给下面与代表框图所示图13.2振荡器振荡器频率内部编程72 kHz的电容CT和修剪电流源.该充放电率控制在产生一个95%在开关输出的最大占空比.在CT的放电,振荡器产生内部消隐脉冲持有的反相输入与门高,禁用输出开关晶体管.标称振荡器峰值和山谷门槛4.1 V和2.3 V分别.3脉宽调制器脉宽调制器由一个比较器振荡器斜坡电压施加到非反相输入端,而误差放大器的输出应用到反相输入.输出开关导通时启动CT检查排放到振荡器峰谷电压.至于收费的CT电压超过误差放大器的输出,锁存复位,终止输出晶体管的导通时间振荡器的ramp–up时期.这PWM /锁存结合防止在给定的多输出脉冲振荡器时钟周期.数字6和14说明开关输出电压与占空比的补偿.4电流检测该系列采用MC34167当前cycle–by–cycle限制,作为保护手段输出开关晶体管从过度紧张.在每个周期视为一个单独的情况.电流限制是通过监测输出开关晶体管的电流传导期间建设,并经检测过流情况,请立即关闭为振荡器的ramp–up期内开关.集电极电流转换为电压由内部微调电阻和对一个参考比较由电流检测比较器.当电流限制达到阈值,比较器重置PWM 锁存.限流门限点往往设在6.5 A.图9说明开关与输出电流限制门槛温度.5误差放大器和参考一个误差放大器的高增益提供了访问反相输入和输出.该放大器具有典型dc电压增益80 dB,和单位增益带宽600 kHz与相边缘 70度(图3).同相输入偏置内部5.05 V参考并且不固定了.参考具有精度±2.0%在室温下.以提供负载5.0 V中,参考编程50以上mV 5.0 V补偿在电缆的电压降和1.0%从连接器转换器输出.如果转换器设计需要一个输出电压高于5.05 V,电阻更大R1必须加入形成一个分压网络的反馈输入中所示数字13和18.了确定输出方程与分压网络的电压为:Vout+5.05R2R1)1外部回路补偿所需的转换器稳定.一个简单的low–pass滤波器是由连接电阻(R2)从稳压输出到反相输入,以及一系列resistor–capacitor (RF, CF)之间Pins 1和5.补偿网络的元件值显示在电路的申请被选定为each在稳定工作条件下进行测试.该step–down转换器(图18)是最容易补偿稳定.该step–up(图20)和voltage–inverting(图22)配置运作,连续导反激式转换器,而且更难以弥补.该最简单的方法来优化网络是补偿观察输出电压的负载响应一步变化,而调整临界阻尼RF和CF.该最终电路应验证以下四个稳定边界条件.这些条件是最小和最大输入电压,最小和最大负载.通过箝位的电压误差放大器的输出(引脚5)不到150 mV,内部电路将放置到一个低功耗待机模式,从而将权力电源电流36µA与12 V电源电压.图10说明了备用电源电流与电源电压.误差放大器的输出有一个100µA电流源pull–up,可用于实现soft–start.图17显示充电电流源通过一个电容CSS系列二极管.该二极管断开从反馈CSS回路电阻时1.0 M操作它上面的收费销5.范围开关输出输出开关晶体管的设计最大的40 V,以最小的峰值集电极电流时5.5 A.配置为step–down或voltage–inverting应用,如在图18和22,电感会把偏置的输出整流开关关闭时.整流器与较高的正向电压降或长期拖延的时间应该打开不能使用.如果发射器被允许去充分负,集电极电流流过,造成额外的装置暖气,降低转换效率.图8显示到箝位的发射器0.5集电极电流V,在一系列的100µA温度过高.阿1N5825或肖特基势垒整流器相当于推荐履行这些要求.欠压分离欠压分离一直比较成立以保证完全集成电路在输出级的功能已启用.内部参考电压比较器的监测使输出阶段VCC超过5.9 V.为了防止不稳定的输出交叉切换的阈值,0.9 V迟滞.6摩托罗拉设备数据模拟ICMC34167 MC33167热保护内部热关断电路,以保护在事件集成电路的最大结温度超过.当被激活时,通常在170°C,是被迫的锁存成'复位'的状态,关闭输出开关.此功能防止灾难性故障提供偶然的设备过热.它的目的不是要作为一个适当的散热片的替代品.该MC34167包含在5–lead TO–220类型包装.该标签包装是很常见的中心引脚(引脚3),通常连接到地.设计考虑不要试图建立一个转换器上wire–wrap或plug–in原型板.特别应注意分开的信号电流和接地接地通路从负载电流路径.所有高电流回路应尽可能短尽可能使用重型铜runs到尽量减少振荡和辐射EMI.为了获得最佳的操作,严密元件布局建议.电容器Cin, CO,和所有的反馈元件应尽可能靠近IC在身体可能.这也是必须的肖特基二极管连接到开关输出是尽可能靠近尽可能IC.图15.低功耗待机电路+100µA错误放大器1图16.过电压关断电路+100µA错误放大器1120补偿5120补偿R15R1I =待机模式VShutdown = VZener + 0.7图17. Soft–Start电路+100µA错误放大器1120补偿D2Vin1.0 MCss5D1R1tSoft–Start≈35,000 Css。
BX-301M ID R ANGE M EMBRANEI NSTRUCTIONSMet One Instruments, Inc.1600 NW Washington Blvd.Grants Pass, Oregon 97526Telephone 541-471-7111Facsimile 541-471-71161 About the BX-301 Mid-Range MembraneThe BX-301 is a special purpose mid-range membrane foil assembly which may be used to verify the linearity of the BAM-1020 mass calculation system. The mass calculation of the BAM-1020 is inherently linear in nature, and therefore it is unnecessary to audit a mid range point in the vast majority of applications. The BX-301 is provided only as a convenience to certain customers who may be required to perform the check by local regulations.The BAM-1020 unit performs a span membrane check automatically every hour using it’s built-in membrane with a mass of approximately 0.800 mg/cm2. The BX-301 allows the user to periodically perform an additional span check at about 0.500 mg/cm2.The BX-301 membrane is a fragile assembly, and must be handled very carefully. Any puncture or damage to the foil surface will render the part useless. Any dirt or contamination on the foil surface will be measured as mass, and will also invalidate the measurement. This assembly must be protected and stored in a safe location away from heat and direct sunlight.2 Mid Range Span Check ProcedureNote: The BAM-1020 unit must be powered on and warmed up for at least one hour before performing the test. The pump does not need to be running during warm-up.1. Remove the ten case cover screws and washers from the BAM-1020. You will needto access the inside of the unit later to complete the test.2. Verify the factory determined ABS value of the BAM-1020 unit. This can be found inthe SETUP > CALIBRATE menu or on the calibration certificate for the unit. This is the expected mass of the span membrane foil in the unit, and will be about 0.800mg/cm2.3. Enter the TEST > CALIBRATE menu on the user interface. This is the screen thatwill be used for the membrane tests. See Section 7.13 of the BAM-1020 manual.The CALIBRATE Test Screen4. Press the START soft key to start a membrane measurement with the existing foil.The test will take about eight minutes to complete. The unit will then display themeasured value of the span membrane foil as the CAL MASS M value. Comparethis value with the ABS (expected) value and record the results. These shouldtypically match within a few micrograms. Note: If these values disagree by 5% ormore, then there is something wrong with the unit such as a dirty membrane or an incorrect ABS value. Do not proceed with the test if the BAM-1020 is not reading its own membrane correctly.5. Remove the BAM case cover. Locate the membrane assembly on the inside of theunit, and the brass raceway in which the membrane assembly slides forwards and backwards. Remove the small dust cover (two small screws and washers). Set the parts aside.MembraneMotorDust CoverMembraneAssemblyMembraneControl ArmThe Membrane Assembly Inside the BAM-10206. Carefully remove the existing membrane from the unit: Pull back the control armagainst it’s spring pressure until you can slide the membrane from the back of the assembly. There should be an expected mass value printed on the back of the mid-range membrane. Record this value. Insert the mid-range membrane foil exactly as the other membrane was installed. Note: Make sure the pin of the membrane is in the slot of the control arm, or the test will not work. Swapping membranes is a very simple matter once you know what you are doing.7. Press the START soft-key to start the test with the mid-range membrane in place.When the unit has calculated and displayed the new CAL MASS M value, record it and start the test over. Perform the test two more times and take an average of the three measured values. This average must be within 5% of the expected valueprinted on the membrane, and will typically be within a few micrograms. Record the results.8. Remove the mid-range membrane and replace the original part. Reinstall the smalldust cover and the main case cover of the BAM-1020.BAM-1020 Membrane Foil Mid-Range Linearity CheckTest Results Record:Test Performed By:Test Date:BAM-1020 Serial Number:Expected ABS Value:mg/cm2Measured Mass of Existing Foil:mg/cm2Difference:mg/cm2Difference %:%Expected Mass of Mid-Range Foil:mg/cm2Measured Mid-Range Mass, Test 1:mg/cm2Measured Mid-Range Mass, Test 2:mg/cm2Measured Mid-Range Mass, Test 3:mg/cm2Average Mid-Range Mass:mg/cm2Difference from Expected Value:mg/cm2Difference %:%。
Motorola MC145162/D (CMOS)翻译——中文福州大学林仁杰翻译一、简介MC145162(可编程的双PLL(锁相环)频率合成器),最高频率可达到60 MHz 和85 MHz 。
适合配合MC3361,MC3362,MC2833等调频发射接收模块的使用,适用于全球范围内的CT-1制式的无绳电话。
同样适用于需要60 MHz以下的频率其它产品。
MC145162-1是MC145162的高频版本,工作频率高达85 MHz。
通过MCU的串行接口,我们可以非常方便地操作它的完全可编程的接收、发射、参考、辅助参考计数器。
正因为这样,所以它可使用于任何CT-1制式的无绳电话。
本元件的发射环和接收环各有一个独立的相位检测器。
一个共用的参考晶体,驱动两个独立的参考频率计数器,为发射环和接收环提供了独立的参考频率。
如果有需要的话,辅助参考计数器可以让我们为发射环和接收环选择一个额外的参考频率。
二、参数范围工作电压范围:2.5 到5.5 V。
工作温度范围:–40 到+75℃功耗:3.0 mA @ 2.5 V最大工作频率:MC145162 - 60 MHz @ 200 mV p–p, VDD = 2.5 VMC145162-1 - 85 MHz @ 250 mV p–p, VDD = 2.5 V可选3线或者4线的串行接口。
内置MCU时钟输出,值为参考晶体的频率÷3/÷4可选。
可由MCU的MCUCLK脚控制省电模式。
内置的参考晶体,支持外置的晶体可达16.0 MHz。
参考频率计数器的分频范围:16-4095辅助参考频率计数器的分频范围:16-16,383发射计数器的分频范围:16-65,535接收计数器的分频范围:16-65,535三、管脚定义输入端:OSCin/OSCout——参考晶体输入/输出引脚(第7、8脚)当连接到一个外接的并联谐振晶体的时候,这些引脚组成了一个参考振荡器。
应用在各国的无绳电话时,图6显示了不同的晶体频率和参考频率的关系。
CX331、CX431、MC3224、MC3326、MC3426、XC2326 多功能複合機用戶手冊2021 年 9 月機型:3500內容安全資訊 (6)印刷慣例 (6)產品聲明 (6)瞭解印表機 (8)尋找印表機相關資訊 (8)尋找印表機序號 (9)印表機配置 (10)使用控制面板 (12)自訂主畫面 (12)變更顯示幕上的鍵盤語言 (12)瞭解指示燈的狀態 (13)選取紙張 (13)設定、安裝和配置 (19)選取印表機放置地點 (19)連接纜線 (20)安裝選購性紙匣組件 (20)設定及使用主畫面應用程式 (21)設定印表機傳真功能 (23)配置電子郵件 SMTP 設定 (30)置入紙張和特殊媒體 (37)安裝與更新軟體、驅動程式和韌體 (41)可用選購品 (44)網路 (45)列印功能表設定頁 (49)進行印表機安全防護 (50)清除印表機記憶體 (50)回復出廠預設值 (50)揮發性聲明 (50)列印 (51)從電腦列印 (51)從快閃儲存碟列印 (52)支援的快閃硬碟和檔案類型 (53)配置機密工作 (54)列印機密工作和其他保留工作 (55)從雲端連結器設定檔列印 (55)列印字型範例清單 (56)在列印副本之間放置分隔頁 (56)取消列印工作 (56)調整碳粉明暗度 (56)複印 (57)使用自動送稿器或掃描器玻璃面板 (57)進行複印 (57)複印相片 (57)複印在信頭紙上 (57)複印在紙張的正反面 (58)縮小或放大複印文件 (58)將多頁複印在單張材質上 (58)逐份列印份數 (58)複印證件 (58)建立複印快捷鍵 (59)電子郵件 (60)使用自動送稿器或掃描器玻璃面板 (60)傳送電子郵件 (60)建立電子郵件快捷鍵 (60)傳真 (62)使用自動送稿器或掃描器玻璃面板 (62)傳送傳真 (62)排定傳真的時程 (63)建立傳真目的地快捷鍵 (63)變更傳真解析度 (63)調整傳真明暗度 (63)列印傳真日誌 (64)封鎖垃圾傳真 (64)轉發傳真 (64)掃描 (66)使用自動送稿器或掃描器玻璃面板 (66)掃描至電腦 (66)使用快捷鍵掃描至 FTP 伺服器 (67)使用快捷鍵掃描至網路資料夾 (68)掃描至快閃硬碟 (68)掃描至雲端連結器設定檔 (69)使用印表機功能表 (70)功能表圖 (70)裝置 (71)列印 (82)紙張 (87)複印 (89)傳真 (91)電子郵件 (101)FTP (105)USB 磁碟機 (107)網路/連接埠 (111)安全性 (123)雲端連結器 (127)報告 (127)疑難排解 (128)維護印表機 (129)檢查零件及耗材狀態 (129)配置耗材通知 (129)設定電子郵件警示 (129)檢視報告 (129)訂購零件及耗材 (130)更換零件及耗材 (133)清潔印表機零件 (147)省電與省紙 (153)將印表機移到其他地點 (154)問題疑難排解 (156)列印品質問題 (156)列印問題 (157)印表機未回應 (181)無法讀取快閃儲存碟 (182)啟用 USB 連接埠 (182)網路連線問題 (183)耗材問題 (184)清除夾紙 (186)送紙問題 (198)電子郵件問題 (200)傳真問題 (201)掃描問題 (206)色彩品質問題 (211)聯絡客戶支援中心 (213)回收和丟棄 (214)回收利用 Lexmark 產品 (214)回收 Lexmark 包裝材料 (214)注意事項 (215)索引 (223)安全資訊印刷慣例請注意:請注意表示可能對您有幫助的資訉。