a survery on dynamic spectrum management
- 格式:pdf
- 大小:297.42 KB
- 文档页数:9
lpddr adaptive refresh management -回复LPDDR Adaptive Refresh Management: A Comprehensive GuideIntroductionDRAM power consumption has become a critical concern in mobile devices, where the data stored in main memory plays a significant role. LPDDR (Low Power Double Data Rate) is a low-power and high-performance memory technology commonly used in smartphones, tablets, and other portable devices. In this article, we will delve into LPDDR Adaptive Refresh Management, a technique designed to optimize power consumption while ensuring data integrity.1. Understanding LPDDR Adaptive Refresh Management LPDDR Adaptive Refresh Management is a mechanism used to dynamically adjust the DRAM refresh rate based on system requirements. Traditionally, DRAM refreshes at a fixed rate of every 64ms to prevent data loss due to charge leakage. However, in modern mobile devices, this fixed refresh rate can be wasteful in terms of power consumption.2. The Significance of Adaptive Refresh ManagementWith increasing memory capacities in mobile devices, DRAM refresh consumes a substantial amount of power. This excessive power usage results in reduced battery life, limiting the usability of portable devices. Adaptive Refresh Management aims to address this issue by adjusting the refresh rate according to the system's current memory usage.3. The Operating Principles of Adaptive Refresh Management Implementing Adaptive Refresh Management involves monitoring various parameters to determine the optimal refresh rate. These parameters include data retention time, data access frequency, and DRAM temperature.a. Data Retention Time: DRAM cells gradually lose their charge over time, leading to data corruption. Data retention time varies based on temperature and voltage. Adaptive Refresh Management analyzes the temperature and voltage conditions to estimate the data retention time and calculate the required refresh rate.b. Data Access Frequency: Adaptive Refresh Management tracks how frequently memory cells are accessed. If a specific memory region remains untouched for an extended period, reducing therefresh rate for that region can result in power savings without compromising data reliability.c. DRAM Temperature: Temperature affects both data retention time and power consumption. Higher temperatures increase charge leakage and, thus, require more frequent refreshes. Adaptive Refresh Management takes DRAM temperature into account when adjusting the refresh rate.4. Implementation ChallengesImplementing Adaptive Refresh Management presents some challenges that need to be overcome to ensure its effectiveness.a. Accuracy: Accurately estimating data retention time based on temperature and voltage is crucial for efficient adaptive refresh management. Inaccurate estimations can lead to unnecessary refreshes, adversely impacting power savings.b. Overhead: The mechanism to monitor memory access frequency and track data retention time adds an overhead to the system. Balancing the overhead and power savings is a challenge that needs careful consideration during implementation.c. Dynamic Changes: The refresh rate adjustment must be responsive to changes in memory usage. The system must be able to quickly adapt to alterations in memory access patterns to maintain optimal power savings.5. Benefits of Adaptive Refresh ManagementAdaptive Refresh Management offers several benefits for mobile devices:a. Improved Power Efficiency: By dynamically adjusting the refresh rate, power consumption can be significantly reduced, leading to extended battery life.b. Enhanced Performance: Adaptive Refresh Management optimizes memory resources, ensuring that frequently accessed memory regions are refreshed more often, improving overall system performance.c. Increased Reliability: Despite reducing the refresh rate, data integrity is maintained through accurate estimation of data retention time. The system ensures that necessary refreshes areconducted to prevent data corruption.ConclusionLPDDR Adaptive Refresh Management is a powerful technique that optimizes power consumption while preserving data integrity in mobile devices. By dynamically adjusting the refresh rate based on system requirements, adaptive refresh management significantly improves power efficiency, enhances performance, and ensures reliability. As mobile devices continue to evolve, the implementation of LPDDR Adaptive Refresh Management becomes even more crucial in delivering optimal user experience and maximizing battery life.。
Sennheiser electronic GmbH & Co. KGAm Labor 1, 30900 Wedemark, Germany Publ. 01/18, 575861/A01Quick Guide Kurzanleitung Guide rapide Guida rapidaGuía de inicio rápido Guia rápidoBeknopte handleiding Krótka instrukcja obsługi SnabbguideKort vejledning PikaohjeΓρήγορος οδηγόςKısa KılavuzКраткая инструкция快速指南快速使用指南 퀵 가이드ew 300-500 G4Sennheiser Documentation Appor online at /downloadew 300-500 G4_EM 300-500SK 300 | SK 500SKM 300 | SKM 500BatteryLow BatterySetupOnOffMenuStandard displayew G4MHz 548.100PAFORORORew G4MHz 533.875PAFORP548.100SKM300B.Ch: U1.32MUTE AF Out: +18 dBEQMHzew G4PPEAK-10040302010-20-40AFRF-30TX MuteMHz 548.100ew G4MUTEAFMHz 548.100ew G4MUTEAFMHz548.100B.Ch: 1.1MUTEAFB.Ch: 1.1MUTEAFew G4M I CR U E D IV E R S IT Y R E C E IV E R 30020.12S K 300PP E A K-100402510-20-30A FR FSETSETSYNC548.100SKM300B.Ch: U1.32MUTE AF Out: +18 dBEQMHzew G4PPEAK-10040302010-20-40AFRF-30TX MuteWarnings LEDSync LED Sync548.100B.Ch: U1.32AF Out: +18 dBEQP0548.100Soundcheck AF Out: +18 dBEQP0548.100SKM 300Sensitivity: –30 dB0Standard Instruction Manual Instruction ManualInstruction Manual548.100SKM300B.Ch: U1.32MUTE AF Out: +18 dBEQMHzew G4P-10040302010-20-40AFRF-30TX Mute100 %70 %30 %>8 h 4 - 6 h 2 - 3 hLOW BATT123123123EU KORCN USUKAU6.3 mmXLR-3SK/SKMEM short long on on/RX mute onon/RF muteEM/SK/SKMlongoffMuteSquelch Easy SetupFrequency Preset Name AF Out Equalizer Auto Lock Advanced ExitMain menu “Menu”Reset List Current List Scan New List Exit“Easy Setup”TuneSync Settings Pilot ToneFullscreen Warnings Brightness ResetIP AddressSoftware Revision ExitExtended menu “Advanced Menu”ON/OFFESCSETUP DOWN Extended menu “Advanced Menu”TuneMute Mode (SK/SKM 300)MIC LED (SK/SKM 300)RF Power Pilot Tone LCD Contrast ResetSoftware Revision ExitMain menu “Menu”SensitivityFrequency Preset Name Auto Lock Advanced ExitUPDOWNSET ON/OFF ESCUPDOWNSETON/OFF ESCACBACBNameRadiofrequency levelPilot tone Equalizer Audio level SensitivityDiversityMute BatteryAuto lockSquelchBank . Channel FrequencySyncChange frequency TransmitterWarningsPeak holdFrequencyPilot toneRF onAudio levelChange frequencySensitivityMuteBatteryAuto lockPeak holdSK 300SK 5004SKM 300SKM 500AF OutAuto lock MuteSquelch Change frequency New frequencySyncNetwork ControlMultichannel - Easy SetupSKMME 2 | MKE 2SL Headmic 1AF out SensitivityInstruction ManualshortInstruction ManualM U T EshortRMS 1shortOR40302010RFInstruction ManualSquelch Easy SetupFrequency PresetMenu Current List Scan New List ExitEasy Setup StoredScan New List 518 . . . 558 MHz1 . . . 20Bank U6Bank 1Bank 2Easy Setup Free: 24B.Ch: 2. 1Sync 558.025MHz Easy Setupew300 G3Frequency PresetMenuB.Ch: 1.1Frequency Preset 558.025 MHz B.Ch. 2.6Frequency Preset 558.025 MHzB.Ch. 2. 1StoredORORLEVELAF–24 dB . . . +24 dBRJ 45Menu Squelch Frequency Preset0Easy SetupInstruction ManualMenuAF Out +18dBName EqualizerPEAK-10040302010-20-40AFRF-30MenuSquelch 9dBExit Easy SetupPEAK-10040302010-20-40AFRF-30-10040302010-20-40AFRF-30-10040302010-20-40AFRF-30Instruction ManualPEAK -100-20-30PEAK-100-20-30AFAFMenu –24 dBSensitivityAF Mute Mute OnMute OffMute OnMute OffRF MuteRF Mute On?RF Mute Off?SETM I C0SKM(SK 300)(SK 300)SK 300SK 300SK 500SKM 300SKM 500EM 300-500EM SK 321321321Auto lock10 sSET SETLockedUnlock?SET SET SET SETLockedUnlock?SETSETSETSETSETSETAdvancedMenuMute ModeAdvanced AF On/Off AF On/OffMute Mode RF On/OffMute Mode Push to TalkMute Mode Push to MuteMute Mode max.32 channelsBank 1 . . . 20; U1 . . . U6Channel 1 . . . 32125 dB5 dB23SKM/SK off!Easy Setup EMFrequency Preset EM, SK, SKM1No frequency Squelch: Middle ...SETSETSETSETWAIT 30 sSETSETSET≤ 10 cm ≤ 4"425 cm (10")ME 2MKE 2–48 dB . . . 0 dB–60 dB . . . 0 dB AF PEAKRX Mute On?RX Mute Off?LockedUnlock?SKM 300MICWSMMedia ControlSennheiser Control Cockpit 2...3 cm (1")。
•12-Bit Resolution for outstanding accuracy over wide measurement ranges •Easy to scale recorded data into user-defined units •Up to four input channels for analog current loop and voltage signals •Self-powered for long-term worry-free performance •Removable terminal block makes wiring connections a snap Spectrum 4000 Universal Input Logger Spectrum 4000 Universal Input Loggers are convenient and versatile units for reliable recording of a wide range of measurement variables.Palm-sized and self-powered, these advanced data loggers work with industry-standard sensors,transmitters and signals to help you quickly and flexibly acquire your important information. Available in single and multi-channel versions for logging analog voltage or current loop signals, each Spectrum 4000 is based on the proven Spectrum 12-bit logger platform that provides you with superb resolution and accuracy over even the widest measurement ranges.Ease-of OperationSpectrum 4000 Loggers are incredibly simple to setup and use. Just connect two wires from your monitoring device to your logger’s input channel using the screw-type terminal block. Then fill out a simple form in software to describe the scaling and measurement units you want. Save the form and all setup and scaling information is stored securely in the logger.No programming or complex equations are required and once set up, the Spectrum 4000 automatically converts recorded results into familiar engineering units for display, analysis and presentation.Simple yet Powerful SoftwareSpectrum software makes it easy to work with your Spectrum 4000 loggers. With just a few keystrokes,you can create outstanding graphic and tabular representations of your data, overlay graphs from different loggers, display data in real-time, export files to your favorite programs and much more.For more advanced applications, the Spectrum Application Program Interface (API) makes it easy to write custom software to communicate with Spectrum 4000 Loggers. This allows you to merge the Spectrum data recording system into your existing operations, procedures and programs.Wide Range of Applications Spectrum 4000 Loggers are ideal for interfacing to any equipment supplied with analog voltage or current loop outputs. This includes a wide range of test and measurement instrumentation for monitoring pressure, flow, fluid level, PH, electrical properties, moisture, gas concentrations and much more. It is perfect for researchers, building operators, test & measurement engineers and quality control personnel.Spectrum 4000 loggers are also available in board-only versions for Original Equipment Manufacturers (OEM’s) who want to conveniently add data logging capabilities to their existing equipment or instrumentation products.。
OverviewRubrik, the Zero Trust Data Security Company™, delivers data security and operational resilience for enterprises. Rubrik provides data security and data protection on a single platform, going beyond just backup and recovery with Zero Trust Data Protection, Ransomware Investigation, Incident Containment, Sensitive Data Discovery, and Orchestrated Application Recovery. Data is ready at all times so users can recover the data they need, and avoid paying a ransom. Rubrik’s software solution scales linearly and can be quickly deployed anywhere across on-prem, hybrid cloud, and multi-cloud environments to protect physical, virtual, and cloudnative apps.Discovery QuestionsDue to a massive increase in cyber-attacks, security is top of mind to every customer and vertical. What are you doing to ensure your data is safe and recoverable?Rubrik cyber resilience capabilities empower IT and Security teams across the lifecycle of a cyber incident. Rubrik can identify indicators of compromise from backup data to alert teams and help contain the impact of ransomware. Rubrik can also perform analytics across snapshots to identify the last knowngood state to prevent reinfection and delayed recovery. Plus, Rubrik can preserve point-in-time snapshots for use in both internal post incident reviews and cyber investigations for external regulatory compliance.What tools are you using to drive efficiencies in delivering IT services via automation?Rubrik enables users to build custom workflows through integrations with automation tools such as Terraform, ServiceNow, Chef, Puppet, and Ansible.Every organization has a different stance on Cloud. What does cloud mean for your business? Rubrik simplifies multi-cloud data protection across AWS, Azure, Google Cloud, Microsoft 365 andhybrid-cloud workloads, facilitating compliance and governance with centralized reporting. Rubrik also optimizes storage costs with tiering, and automates backup across hundreds of cloud accounts.Microsoft has also made an equity investment in Rubrik, partnering with Rubrik to deliver regulatorycompliance tools alongside data security. One such benefit is Rubrik Cloud Vault, built to reduce the risk of backup data breach, loss, or theft. Rubrik Cloud Vault is a fully managed solution for isolated, offsite cloud archival, allowing users to set up archival policies, select the tier and available regions, and begin direct, authenticated Azure Blob integration for encrypted data upload.Target Customer•Decision-maker is VP of Infrastructure,IT Director/Manager•User is IT Ops, Systems or Network Manager/Admin, Virtualization or Backup Admin•Influencer is SecOps, DBA, Enterprise Architect •Looking to reduce risk of paying the ransom inthe case of ransomware attack•Using enterprise backup software/storage •Looking to reduce financial, operational, andbusiness costs of backup, archival, test/dev •Using or exploring private/public cloud archival(object store, Azure, AWS, GCP)What is your current disaster recovery solution?Rubrik customers can migrate VMs to public cloud; Rubrik automatically converts vSphere and Hyper-V VMs to cloud-native instances such as Amazon EC2 and Azure VM. Rubrik also provides “Brik-to-Brik” replication that is WAN-optimized, meaning that Rubrik minimizes the amount of data sent over long distance network connections. And, Rubrik offers Orchestrated Application Recovery, automating the configuration process for VMs, taking into account application dependencies with predefined blueprints for 2-click DR.Are you meeting your backup and recovery objectives/SLAs?Rubrik customers reduce RTOs and RPOs from hours to seconds With Continuous Data Protection, users can recover missioncritical VMs to just seconds before a disaster or corruption point.Rubrik’s SLA policy engine also simplifies compliance for a “set-it-and-forget-it” approachto backup, replication, and archival.Object HandlingOur air gap has to be physical.99.9% of Rubrik customers buy Rubrik for the security of a physical air gap without the need and the cost/expense of implementing one. But if you do want a physical air gap, Rubrik has options.Aren’t you just going to restore infected files? How do you know what point to recover to?Rubrik users can threat hunt within backups and restore everything except the executable that launched the attack. Rubrik can show what the executable did and if sensitive or regulated data was in scope. Everyone says they are immutable. How is Rubrik any different?Immutability is table stakes these days. Rubrik solutions offer not only that, but also help organizationsin terms of speeding up time to recovery, identifying the blast radius of an attack, and identifying what sensitive data has potentially been impacted in order to help customers get back up and running quickly.I don’t buy into the Zero Trust hype. What does it even mean?Assume a breach has already happened. Authenticate everything. Trust nothing. That is a cornerstone of a successful cyber resilience program and what many executives and boards ask for. It’s also a vital, last line of defense approach. One of the most trusted roles is the backup admin. If they go rogue, and expire all of an organization’s backups, Zero Trust is a critical platform defense strategy. With Rubrik,all data is encrypted and logically air gapped from the rest of the environment, with all access governed by comprehensive authentication and access controls.Unique Selling Points1. Built-in recovery: Recover quickly from ransomware and other DR events via immutable backups, ML-driven detection, detailed impact analysis, and single-click recovery.2. High performance (backup and recovery) at large scale: Near-zero RTOs for VMs and databases via Live Mount. Accelerate test/dev, perform application health checks, and deliver ad-hoc restores with self-service access.3. Policy-driven automation to simplify management operations and protect more apps.4. An API-first design that makes it easy to integrate data management into a larger IT environment for greater efficiency and control.5. Automated protection that applies SLA policies to new cloud applications.6. Consolidated multi-cloud protection eliminates the need to rely on multiple native tools.7. Easy configuration and control with SaaS-based management.8. Zero Trust Security protects cloud and SaaS data so that applications running on-prem, at the edge, and in the cloud can be recovered reliably. Rubrik indexes all app data stored in the cloud,enabling instant access to cloud data through predictive search.Customer Use CasesWED2B prevented disruption from a ransomware attack in November 2019,restoring critical SQL databases with Active Directory immediately. “With Rubrik,we experienced zero data loss, zero impact to our core business, we paidnothing in ransom fees and were up and running in 24 hours, which is fantastic”Rob Mole, Head of IT & Solutions.Langs Building Supplies was hacked in May of 2021. With Rubrik, they recovered100% of their data within 24 hours and paid $0 in ransom. CIO, Matthew Day,stated “Rubrik is not just about recovering from ransomware. Rubrik is thedifference between survival and non-survival in this new digital age.”Colchester Institute recovered from a crippling ransomware attack within daysleveraging Rubrik Zero Trust Data Security. Ben Williams, IT Services Managersaid, “Rubrik safeguarded our backups. Due to its native immutability, 100% ofour backups were protected against corruption and deletion. We were able tokeep the lights on and deliver a robust service to our students and staff.Estée Lauder — Leading house of prestige beauty, Estée Lauder is a collection ofover 25 globally renowned beauty brands, each with its own unique set of dataand unique challenges. To protect all data at scale while keeping costs low, thebeauty company partners with Rubrik to break free from legacy data protectionand mobilize to the cloud.For more customer stories, check out /customers。
Product Release Notes1. General Release InformationThe ATTO Configuration Tool helps you customize the settings of your ATTO storage Controller to maximize the performance of your storage connection. While the factory settings on your host adapter should provide excellent performance for a wide range of applications, some specialized applications may benefit from modification of the adapter settings to tune the adapter for a specific performance range.These product release notes define the new features, changes, known issues and release details that apply to the ATTO Configuration Tool v4.09 that was released on November 29, 2012. This information pertains to the Microsoft® Windows OS including Windows XP, Vista, 7, 8, Server 2003, 2008, 2008 R2 and 2012.2. Changes∙Version 4.09 (Released 11/29/12)o The following apply to changes made from v4.08 to v4.09. You must use the latest product drivers for your specific adapter whenever updating the ATTO Configuration Tool version. Thelatest driver sets can be accessed via the ATTO website.o New Features, Enhancements and Changes▪ A new tab has been added to manage NPIV settings▪The ConfigTool now supports NPIV on windows platforms only▪Celerity 16Gb support to the Windows and Linux diagnostic scripts▪Devices can be added/removed in a rapid fashion without consequence▪The adapter buzzer now sounds for non-Thunderbolt adapters when clicking thenotification test button∙Version 4.08 (Released 11/08/12)o The following apply to changes made from v4.07 to v4.08. You must use the latest product drivers for your specific adapter whenever updating the ATTO Configuration Tool version. Thelatest driver sets can be accessed via the ATTO website.o New Features, Enhancements and Changes▪Added process power management events from the ESASRAID driver▪Activated the on-board buzzer on the adapter that triggered a buzzer event only▪Added detect mute button events from ThunderStream products▪Resolved a timing related crash on shutdown if SNMP is enabled▪Resolved a crash when committing the Notifications Plane contents with an emailpassword▪Resolved conflict with StorNext▪Made changes to the operating system display for Window 8∙Version 4.07 (Released 09/28/12)o The following apply to changes made from v4.05 to v4.07. You must use the latest product drivers for your specific adapter whenever updating the ATTO Configuration Tool version. Thelatest driver sets can be accessed via the ATTO website.o New Features, Enhancements and Changes▪Removed the discovery mode option in the NVRAM panel for a 16Gb Celerity FCadapter.∙Version 4.05 (Released 08/13/12)o The following apply to changes made from v4.03 to v4.05. You must use the latest product drivers for your specific adapter whenever updating the ATTO Configuration Tool version. Thelatest driver sets can be accessed via the ATTO website.o New Features, Enhancements and Changes▪Added support for OEM branding.▪Added support for time-stamped log messages from a RIAD device.∙Version 4.03 (Released 04/23/12)o The following apply to changes made from v4.02 to v4.03. You must use the latest product drivers for your specific adapter whenever updating the ATTO Configuration Tool version. Thelatest driver sets can be accessed via the ATTO website.o New Features, Enhancements and Changes▪The installer now makes the application available to all users.▪Several freezes in the system service have been resolved.▪Several crashes related to the auto discovery system were resolved.∙Version 4.02 (Released 02/14/12)o The following apply to changes made from v4.01 to v4.02. You must use the latest product drivers for your specific adapter whenever updating the ATTO Configuration Tool version. Thelatest driver sets can be accessed via the ATTO website.o New Features, Enhancements and Changes▪SNMP support has been added.▪Help menu now features a ‘Run Diagnostics’ option for troubleshooting purposes, which displaces the former option to save logs under the Notifications panel. RAIDlogging has also been improved.▪Support for FastFrame CT and NT adapter series has been added.▪Gen 3 PCIe transfer rate support has been added.▪Hot spares can now be assignable to RAID groups via CLI.▪Support for sounding the buzzer on buzzer-equipped hardware, controllable by the Notification Application.▪Performance, stability and logging improvements.∙Version 4.01 (Released 09/06/11)o The following apply to changes made from v4.0 to v4.01. You must use the latest product drivers for your specific adapter whenever updating the ATTO Configuration Tool version. Thelatest driver sets can be accessed via the ATTO website.o New Features, Enhancements and Changes▪The integrated help text features new icons for the buttons the user can click as well as manipulate in the table of contents.▪This release offers improved support and functionality with 3Gb RAID adapters.▪Rare instances of system hangs have been resolved.∙Version 4.0 (Released 08/17/11)o The following apply to changes made from v3.38 to v4.0. You must use the latest product drivers for your specific adapter whenever updating the ATTO Configuration Tool version. Thelatest driver sets can be accessed via the ATTO website.o New Features, Enhancements and Changes▪Support for ExpressSAS H6F0GT.▪This release represents a major update to the GUI interface and capabilities. Whereas previous versions contained a single application, this release provides a GUIapplication and system service. Refer to the product manual for more information onthe setup and operation of these components.▪This release offers the ability to set-up, manage and optimize storage connected locally and remotely to ATTO storage controllers. This includes the ability to remotely accessand update NVRAM settings, updating system firmware and drivers, as well asretrieving system event logs.▪Only one instance of the ConfigTool can be installed on a host at any one time (i.e.either v3.38 or v4.0, but not both).This version does not have SNMP enabled. Use an earlier version of the ATTOConfigTool if you require SNMP.3. Known Issues/Advisements∙Windows XP x64 and Windows 2003 machines do not display a message when the system is prompted to shut down via the ConfigTool.∙The Notifications tab can be viewed and changed without logging into a host. Additionally, the Notifications tab doesn’t detect if a connected host has disconnected, and thus the informationdisplayed may become stale.∙The audible and visual notifications only work with the system service on the local machine (not remotely).∙Drives may not disappear in the ConfigTool if a cable is pulled with no IO.∙The ConfigTool client doesn’t detect when it has been disconnected from a daemon.∙Manually entered IP addresses or hostnames are not saved.∙Installer extraction process does not automatically start the installation process on Windows.∙If many notifications pop-up, the Notification Application may stop responding.4. Affected ProductsATTO ConfigTool for the following ATTO products:ATTO ExpressSAS H6F0GT, H6F0, H60F, H680, H608, H644, H30F, H380, H308ATTO ExpressSAS RAID Adapters R30F, R380, R348, R60F, R680, R608, R644ATTO Celerity FC-162E, FC-161E, FC-84EN, FC-81EN, FC-82EN, FC-44ES, FC-42ES, FC-41ES,FC-42XS, FC-41XSATTO ExpressPCI UL5D Low-Profile, ExpressPCI UL5D, ExpressPCI UL4DATTO FastFrame Network Adapters CS14, CS12, CS11, NS14, NS12, NS11, NT12, NT11ATTO ThunderStream SC 3808ATTO ThunderLink FC1082, SH1068, NT1102, NS11015. Contacting ATTO SupportATTO Technology, Inc. is renowned for its technical support services. ATTO’s goal is to provide you the quickest response possible for your technical support needs, and is available Monday-Friday, 8:00 AM to 6:00 PM EST (except holidays).ATTO Technical Support can be contacted via phone or email:∙Phone: 716.691.1999 ext. 242∙E-Mail: ************************。
IBM Spectrum ControlVersion 5.2.10Quick Start GuideGet started quickly with installing IBM Spectrum Control storage-management software.Globalization Version: View or download translations of this document from the same location as the English version.Product overviewIBM Spectrum Control™offers licenses with the following features and pricing:IBM Spectrum Control Standard Edition and IBM Spectrum Control Standard Select EditionThese licenses provide the following features:v A single dashboard view of the storage environment, that you can use to manage storage systems, hypervisors,servers, and networksv Capacity and usage monitoring, as well as management and planning for the heterogeneous storage environment v Performance monitoring for storage systems and networksv Health and alerting for storage systems, hypervisors, servers, and networksv Modeling of departments and applications to understand the consumer view of the environmentv The VMware vCenter plug-in, a tool to help you manage and provision virtual storage in a vSphere environment, and view reports about storage systems that are monitored by IBM Spectrum Controlv Reports from IBM®Cognos®Business Intelligence that provide reporting and analytics informationThese licenses include a license for IBM Copy Services Manager, which manages 2-site replication, 3-site replication, and advanced copy services. You can learn more about how to download and install Copy Services Manager at/support/knowledgecenter/SSESK4.The IBM Spectrum Control Standard Edition license is priced by the capacity of the storage systems that it manages.The IBM Spectrum Control Standard Select Edition license is priced by the number of storage enclosures that itmanages.IBM Spectrum Control Advanced Edition and IBM Spectrum Control Advanced Select EditionThese licenses contain everything that is in the IBM Spectrum Control Standard Edition license, plus the followingfeatures:v Analytics-driven, tiered-storage optimization that automatically moves data to the most cost-effective tierv Storage pool balancing, block storage provisioning, and storage reclamationv Application-aware snapshot-based protection that is offered by IBM Spectrum Protect™Snapshotv Roll up reporting that allows capacity data to be combined from multiple instances of IBM Spectrum Control forreporting purposesThe IBM Spectrum Control Advanced Edition license is priced by the capacity of the storage systems that it manages.The IBM Spectrum Control Advanced Select Edition license is priced by the number of storage enclosures that itmanages.If you choose to download and install IBM Copy Services Manager, follow the instructions in the IBM Copy Services Manager Knowledge Center (/support/knowledgecenter/SSESK4). To download and install IBMSpectrum Protect Snapshot, go to IBM Tivoli Storage FlashCopy Manager Knowledge Center (/support/knowledgecenter/SS36V9).2Step 2: Evaluate the hardware configurationReview the hardware requirements. See the IBM Spectrum Control product documentation at Hardware requirements (/support/knowledgecenter/SS5R93_5.2.10/com.ibm.spectrum.sc.doc/fqz0_r_hw_requirements.html).IBM®3Step 3: Evaluate the system configuration and install the prerequisite software Review the software requirements:v Learn about the software requirements for the product at Software requirements (/support/knowledgecenter/SS5R93_5.2.10/com.ibm.spectrum.sc.doc/fqz0_r_sw_requirements.html).v Learn about the hardware, products, and platforms that you can use with IBM Spectrum Control at/support/docview.wss?uid=swg21386446.4Step 4: Install DB2Before you install IBM Spectrum Control, you must install the version of IBM DB2®Enterprise Server Edition that isincluded with IBM Spectrum Control. IBM Spectrum Control stores the information that it collects about storageresources in a DB2 database.Follow the instructions in DB2 (/support/knowledgecenter/SS5R93_5.2.10/com.ibm.spectrum.sc.doc/ fqz0_t_installing_db2.html).5Step 5: Install IBM Spectrum ControlYou can use an installation program or a command line in silent mode to install IBM Spectrum Control. Follow theinstructions in Installing IBM Spectrum Control (/support/knowledgecenter/SS5R93_5.2.10/com.ibm.spectrum.sc.doc/fqz0_t_installing_tpc.html).6Step 6: (Optional) Install Cognos Business Intelligence reportsThe IBM Spectrum Control installation process includes the option to install IBM Cognos Business Intelligence (BI)reports and the product that is required to produce these reports: Jazz™for Service Management and its reportingservices (IBM Tivoli®Common Reporting). Cognos BI produces scheduled reports from the data that is gathered by IBM Spectrum Control.Learn about Cognos BI reports at Reporting (/support/knowledgecenter/SS5R93_5.2.10/com.ibm.spectrum.sc.doc/fqz0_c_webbasedgui_rpting_ic_ov.html). Also learn about the components that you must install to use Cognos BI reports at Install Jazz for Service Management and Tivoli Common Reporting(/support/knowledgecenter/SS5R93_5.2.10/com.ibm.spectrum.sc.doc/fqz0_c_jazzsm_tcr.html).If you choose not to install Cognos BI, you can use the reporting features of the IBM Spectrum Control user interface to produce reports about the status, capacity, and performance of the storage resources that you want to monitor.7Step 7: Get startedFollow the tasks in Getting started with IBM Spectrum Control (/support/knowledgecenter/SS5R93_5.2.10/com.ibm.spectrum.sc.doc/fqz0_r_getting_started.html).More informationFor more information, see the following resources:v General product information: /systems/storage/software/center/index.htmlv PDF product documentation: Printable documentation (/support/knowledgecenter/SS5R93_5.2.10/ com.ibm.spectrum.sc.doc/fqz0_r_printable_pdf_files.html)v Product support: https:///support/entry/myportal/product/tivoli/ibm_spectrum_control/ibm_spectrum_control_standard_edition?productContext=365750483IBM Spectrum Control Version 5.2.10 Licensed Materials - Property of IBM. © Copyright IBM Corp. 2014, 2016. US Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.IBM, the IBM logo, and ®are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at “Copyright and trademark information” (/legal/copytrade.shtml).Printed in Ireland。
Regulatory Model No. SP-2584Data SheetOneStor TMSP-3584Extensible Storage Platform (ESP)Features5U rack-mount enclosure stores up to 5 petabytes of data per rack, saving space in the data center •Certified 80 PLUS Platinum efficient power conversion and adaptive cooling technologyreduces power and cooling costs •Data center space savings + power and cooling cost savings = exceptionally low total cost of ownership•Ultra-dense, with up to 84 3.5” SAS hard disk drives or solid state drives per 5U enclosure •Unique drawer design provides extremely high density per rack unit, and provides easy access to hot swap drives•Capacity of 840Tb in 5U using 10Tb enterprise HDDs•Expansion capability up to 336 drives Dual 12Gb SAS I/O modules with integral data path redundancy•Maximum of 28.8 GB/s in a dual controller configurationThe proliferation of digital content in the enterprise has created increasingly complex and costly storage systems. These systems consume large amounts of energy and prevent companies from easily adapting their IT infrastructure as needs change. As the pace of change continues to accelerate, the evolution of storage technologies has become essential. OEMs and solution integrators need an extensible storage infrastructure that provides flexibility, reliability and energy efficiency to meet diverse application requirements. These include applications in digital media, in compliance retention and in data archival.The OneStor SP-3584 evolves the mature SP-2584 platform to 12G SAS while maintaining the prior architecture utilizing significant hardware reuse, a common management API and SBB 2.0 compatibility. This enables OEMs to accelerate market introduction of new technologies and also significantly simplifies development and testing of storage implementations while reducing overhead.Seagate Advancing 12Gb/s SASSeagate Advancing 12Gb/s SAS The Seagate implementation of 12Gb/s SAS offers a number of significant improvements to 6Gb/s SAS over and above the doubling of the data transfer rate from 6 Gb/s to 12 Gb/s. These include support and capabilities for managed cables, active and optical cables, universal ports, self configuration, and standardized zoning. Seagate supports 12Gb/s SAS in end-to-end configurations providing an effective maximum throughput of 14.4 GB/s per I/O module or 28.8 GB/s in a dual controller configuration, enough to support the highest performing solid state storage devices.Delivering a Versatile & Scalable ArchitectureAs a member of the OneStor family, the SP-3584 leverages the reuse of interchangeable I/O modules, a common enclosure management and SBB 2.0 compatibility. This enables OEMs to accelerate market introduction of new technologies and also significantly simplifies development and testing of storage implementations while reducing overhead.Assuring Robust Data AvailabilityThrough its intelligent Unified System Management (USM), OneStor safeguards data and ensures maximum availability. Users are able to leverage fault diagnosis and resolution capabilities, persistent error logging and monitoring. In addition, OneStor provides high availability features such as dual redundant PSUs, N+1 cooling modules, dual I/O modules and dual data paths to all drives.Customizing to Meet OEM Specific RequirementsOEMs can easily tailor each OneStor platform to meet end product requirements, including colored plastics, custom moldings, labeling, logo printing and product packaging.AMERICAS Seagate Technology LLC 10200 South De Anza Boulevard, Cupertino, California 95014, United States, 408-658-1000 ASIA/PACIFIC Seagate Singapore International Headquarters Pte. Ltd. 7000 Ang Mo Kio Avenue 5, Singapore 569877, 65-6485-3888EUROPE, MIDDLE EAST AND AFRICA Seagate Technology SAS 16–18, rue du Dôme, 92100 Boulogne-Billancourt, France, 33 1-4186 10 00© 2016 Seagate Technology LLC. All rights reserved. Printed in USA. Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. Seagate OneStor is either trademarks or registered trademarks of Seagate Technology LLC or one of its affiliated companies in the United States and/or other countries. All other trademarks or registered trademarks are the property of their respective owners. When referring to drive capacity, one gigabyte, or GB, equals one billion bytes. Your computer’s operating system may use a different standard of measurement and report a lower capacity. In addition, some of the listed capacity is used for formatting and other functions, and thus will not be available for data storage. Actual data rates may vary depending on operating environment and other factors. The export or re-export of hardware or software containing encryption may be regulated by the U.S. Department of Commerce, Bureau of Industry and Security (for more information, visit ), andcontrolled for import and use outside of the U.S. Seagate reserves the right to change, without notice, product offerings or specifications. Issue 1.0 | 2017Take the next step: to learn more about Seagate ®Cloud Systems and Solutions visit /oem。
System x3750 M4 (8722)Product Guide (withdrawn product)The System x3750 M4 is a 4-socket server featuring a streamlined design, optimized for price and performance, with best-in-class flexibility and expandability. Models of the x3750 M4, machine type 8722, are powered with Intel Xeon E5-4600 processors, up to 8 cores each, for an entry-level 4-socket solution. The x3750 M4 provides maximum storage density, with flexible PCI and 10 Gb Ethernet networking options in a 2U form factor.Suggested uses: High performance computing (HPC), workloads with floating-point computations, and small to medium databases requiring fast I/O; applications that require 4-socket performance without needing the scalability that the eX5 systems provide.Figure 1. The System x3750 M4Did you know?The x3750 M4 has outstanding memory performance that is achieved by supporting three-RDIMM-per-channel configurations at speeds up to 25% faster than the Intel specification, while still maintaining world-class reliability. LR-DIMM speeds are also 25% beyond the Intel specification for 1.35 V DIMMs, and this speed improve not only performance, but reduces overall system power at the same time.The x3750 M4 offers a flexible, scalable design and simple upgrade path to 16 hard-disk drives (HDDs) or 32 eXFlash solid-state drives (SSDs), with up to eight PCIe Gen 3 slots and up to 1.5 TB of memory. The flexible embedded Ethernet solution provides two standard Gigabit Ethernet ports onboard, along with a dedicated 10 GbE slot that allows for a choice of either two copper or two fiber optic connections. Comprehensive systems management tools with the next-generation Integrated Management Module II (IMM2) make it easy to deploy, integrate, service, and manage.Click here to check for updatesLocations of key components and connectorsThe following figure shows the front of the server.Figure 2. Front view of the System x3750 M4The following figure shows the rear of the server.Figure 3. Rear view of the System x3750 M4The following figure shows the locations of key components inside the server.Figure 4. Inside view of the System x3750 M4Standard specificationsThe following table lists the standard specifications.Table 1. Standard specificationsComponents SpecificationMachine type8722Form factor2U rack.Processor Up to four Intel Xeon processor E5-4600 product family processors, each with eight cores (up to 2.7 GHz), six cores (up to 2.9 GHz), or four cores (up to 2.0 GHz). Two processor sockets on thesystem board and two processors on the processor and memory expansion tray (standard on mostmodels). Two QPI links up to 8.0 GTps each. Up to 1600 MHz memory speed. Up to 20 MB L3cache per processor.Chipset Intel C600 series.Memory Up to 48 DIMM sockets (12 DIMMs per processor). RDIMMs and LRDIMMs (Load Reduced DIMMs) are supported, but memory types cannot be intermixed. The memory speed is up to 1600MHz. There are 24 DIMM sockets on the system board. There are an additional 24 DIMM socketson the processor and memory expansion tray (standard on most models).Memory maximums With RDIMMs: Up to 768 GB with 48x 16 GB RDIMMs and four processors, With LRDIMMs: Up to 1.5 TB with 48x 32 GB LRDIMMs and four processors.MemoryprotectionECC, Chipkill (for x4-based memory DIMMs), memory mirroring, and memory sparing.Standard modelsThe following table lists the standard models. Table 2. Standard modelsModel Intel Xeon processor†(four maximum)*Memory RAID controller Hot-swapdisk baysDisks PCIe GbE PowersupplyModels announced May 20128722-A1x2x E5-4617 6C 2.9 GHz15 MB 1600 MHz 130W 2x 8 GBRDIMM1600 MHzM5110e4x 2.5"16 maxOpen 5 / 821x 1400W8722-A2x1x E5-4603 4C 2.0 GHz10 MB 1066 MHz 95W*1x 8 GBRDIMM1333 MHzM5110e Open Open 5 / 821x 1400W8722-A3x2x E5-4607 6C 2.2 GHz12 MB 1066 MHz 95W 2x 8 GBRDIMM1333 MHzM5110e4x 2.5"16 maxOpen 5 / 821x 1400W8722-B1x2x E5-4610 6C 2.4 GHz15 MB 1333 MHz 95W 2x 8 GBRDIMM1333 MHzM5110e4x 2.5"16 maxOpen 5 / 821x 1400W8722-B2x2x E5-4620 8C 2.2 GHz16 MB 1333 MHz 95W 2x 8 GBRDIMM1333 MHzM5110e8x 1.8"32 maxOpen8 / 821x 1400W8722-C1x2x E5-4640 8C 2.4 GHz20 MB 1600 MHz 95W 2x 8 GBRDIMM1333 MHzM5110e(1 GB,F,R5)‡4x 2.5"16 maxOpen8 / 821x 1400W8722-C2x2x E5-4650 8C 2.7 GHz20 MB 1600 MHz 130W 2x 8 GBRDIMM1333 MHzM5110e(1 GB,F,R5)‡4x 2.5"16 maxOpen 5 / 821x 1400W8722-D1x4x E5-4610 6C 2.4 GHz15 MB 1333 MHz 95W 24x 8 GBRDIMM1333 MHzM5110e + 1xM5110(512,B,R5,SSD)§16x 1.8"32 max16x 200GSSD8 / 822x 1400W8722-D2x4x E5-4650 8C 2.7 GHz20 MB 1600 MHz 130W 24x 16GBLRDIMM1333 MHzM5110e + 3xM5110(512,B,R5,SSD)§32x 1.8"32 max32x 200GSSD8 / 822x 1400W† Processor detail: Processor quantity and model, cores, core speed, L3 cache, memory speed, and power consumption.* All models except for 8722-A2x include the processor and memory expansion tray containing sockets for processors 3 and 4 and 24 DIMMs. For model A2x, order part number 88Y7365.‡ Models C1x and C2x include the 1 GB Flash/RAID 5 Upgrade (part number 81Y4559) which is a 1 GB flash-backed cache with support for RAID 5.§ Model D1x has two RAID controllers, D2x has four RAID controllers total. D1x and D2x include the 512 MB Cache/RAID 5 Upgrade (81Y4484), plus the Battery Kit (81Y4508), plus the SSD Performance Key (90Y4273) for each controller.Refer to the Standards specifications section for information about the standard features of the server. Processor optionsTable 8. RAID controller upgradesPart number FeaturecodeDescription MaximumsupportedModelswhere used81Y4544A1X2ServeRAID M5100 Series Zero Cache/RAID 5 Upgrade1-81Y4484A1J3ServeRAID M5100 Series 512 MB Cache/RAID 5 Upgrade4D1x (2 standard)D2x, (4 standard) 81Y4487A1J4ServeRAID M5100 Series 512 MB Flash/RAID 5 Upgrade4-81Y4559A1WY ServeRAID M5100 Series 1 GB Flash/RAID 5 Upgrade4C1x (1 standard)C2x (1 standard) 81Y4508A22E ServeRAID M5100 Series Battery Kit4*D1x (2 standard)D2x, (4 standard) 81Y4546A1X3ServeRAID M5100 Series RAID 6 Upgrade**1†-90Y4273A2MC ServeRAID M5100 Series SSD Performance Key**1D1x, D2x90Y4318A2MD ServeRAID M5100 Series SSD Caching Enabler **1-81Y4542A1X1ServeRAID M1100 Series Zero Cache/RAID 5 Upgrade1-* The ServeRAID M5100 Series Battery Kit (81Y4508) is only supported with ServeRAID M5100 Series 512 MB Cache/RAID 5 Upgrade (81Y4484).† The ServeRAID M5100 Series RAID 6 Upgrade (81Y4546) requires RAID 5 upgrades with cache(81Y4484, 81Y4487, or 81Y4559 only).** Only one ServeRAID Feature on Demand upgrade is required per system, regardless of the number of adapters installed.Internal drive optionsThe following table lists the hard disk drive options for the internal disk storage of the x3750 M4 server. Table 9. 1.8-inch SSDsPart number Feature Description Maximum supported1.8-inch hot-swap SSDs - 6 Gb SATA - Enterprise Mainstream (3-5 DWPD)00AJ335A56V120GB SATA 1.8" MLC Enterprise Value SSD32 00AJ340A56W240GB SATA 1.8" MLC Enterprise Value SSD32 00AJ345A56X480GB SATA 1.8" MLC Enterprise Value SSD32 00AJ350A56Y800GB SATA 1.8" MLC Enterprise Value SSD32Table 10. 2.5-inch hot-swap 6 Gb SAS/SATA HDDsPart number Feature Description Maximum supported2.5-inch hot-swap HDDs - 6 Gb SAS 10K90Y8877A2XC300GB 10K 6Gbps SAS 2.5" SFF G2HS HDD16 90Y8872A2XD600GB 10K 6Gbps SAS 2.5" SFF G2HS HDD16 81Y9650A282900GB 10K 6Gbps SAS 2.5" SFF HS HDD16 00AD075A48S 1.2TB 10K 6Gbps SAS 2.5" G2HS HDD16 2.5-inch hot-swap HDDs - 6 Gb SAS 15K90Y8926A2XB146GB 15K 6Gbps SAS 2.5" SFF G2HS HDD16 81Y9670A283300GB 15K 6Gbps SAS 2.5" G2HS HDD16 00AJ300A4VB600GB 15K 6Gbps SAS 2.5" G2HS HDD16 2.5-inch hot-swap HDDs - 6 Gb NL SAS90Y8953A2XE500GB 7.2K 6Gbps NL SAS 2.5" SFF G2HS HDD16 81Y9690A1P31TB 7.2K 6Gbps NL SAS 2.5" SFF HS HDD16 2.5-inch hot-swap HDDs - 6 Gb NL SATA81Y9726A1NZ500GB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD16 81Y9730A1AV1TB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD16 2.5-inch hot-swap SED HDDs - 6 Gb SAS 10K90Y8913A2XF300GB 10K 6Gbps SAS 2.5" SFF G2HS SED16 90Y8908A3EF600GB 10K 6Gbps SAS 2.5" SFF G2HS SED16Table 11. 2.5-inch hot-swap 6 Gb SAS/SATA SSDsPart number Feature Description Maximum supported2.5-inch hot-swap SSDs - 6 Gb SAS - Enterprise Performance (10+ DWPD)49Y6129A3EW200GB SAS 2.5" MLC HS Enterprise SSD16 49Y6134A3EY400GB SAS 2.5" MLC HS Enterprise SSD16 49Y6139A3F0800GB SAS 2.5" MLC HS Enterprise SSD16 49Y6195A4GH 1.6TB SAS 2.5" MLC HS Enterprise SSD16 2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Mainstream (3-5 DWPD)00AJ355A56Z120GB SATA 2.5" MLC HS Enterprise Value SSD16 00AJ360A570240GB SATA 2.5" MLC HS Enterprise Value SSD16 00AJ365A571480GB SATA 2.5" MLC HS Enterprise Value SSD16 00AJ370A572800GB SATA 2.5" MLC HS Enterprise Value SSD16Internal backup unitsThe server does not supports any internal backup units, such as tape drives or RDX drives. Optical drivesTable 15. Network adaptersPart number Feature Description Maximum supported#1 Gb Ethernet49Y42305767Intel Ethernet Dual Port Server Adapter I340-T2 for IBM System x849Y42405768Intel Ethernet Quad Port Server Adapter I340-T4 for IBM System x800AG500A56K Intel I350-F1 1xGbE Fiber Adapter for IBM System x800AG510A56L Intel I350-T2 2xGbE BaseT Adapter for IBM System x800AG520A56M Intel I350-T4 4xGbE BaseT Adapter for IBM System x810 Gb Ethernet49Y7960A2EC Intel X520 Dual Port 10GbE SFP+ Adapter for IBM System x849Y7970A2ED Intel X540-T2 Dual Port 10GBaseT Adapter for IBM System x881Y3520AS73Intel X710 2x10GbE SFP+ Adapter for IBM System x800D9690A3PM Mellanox ConnectX-3 10 GbE Adapter for IBM System x842C18005751QLogic 10Gb CNA for IBM System x890Y4600A3MR QLogic 8200 Dual Port 10GbE SFP+ VFA for IBM System x847C9952A47H Solarflare SFN5162F 2x10GbE SFP+ Performant Adapter for IBM System x847C9960A47J Solarflare SFN6122F 2x10GbE SFP+ Onload Adapter for IBM System x847C9977A522Solarflare SFN7122F 2x10GbE SFP+ Flareon Ultra for IBM System x840 Gb Ethernet00D9550A3PN Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter for IBM System x8# Maximum quantity is achieved with processor 2 installed and the 3-slot riser card (88Y7371). With one processor, the maximum quantity is three (this maximum does not apply to the 10 Gb cards in the dedicated slot).For more information, see the list of Product Guides in the Networking adapters categoryhttps:///servers/options/ethernetStorage HBAs and external RAID controllersThe following table lists storage HBAs supported by x3750 M4 server. The maximum quantity is achieved with processor 2 and the 3-slot riser card (88Y7371) installed. With one processor, the maximum quantity is three (this configuration does not apply to the 10 Gb cards in the dedicated slot).Power suppliesThe server supports up to two redundant power supplies. Standard models come with one or two 1400 W power supplies (model dependent; see Table 2). 900 W AC and 750 W DC power supplies also available through CTO or Special Bid.Installing a second power supply requires that the processor and memory expansion tray (88Y7365) or the power interposer card (88Y7367) be installed. The power interposer card option enables redundancy power support when the processor and memory expansion tray is not installed. If you do not have the processor and memory expansion tray installed and want to install two power supplies, then the power interposer card must be installed.Table 19. Power suppliesPart number Featurecode Description MaximumsupportedModelswhere used88Y7373A2A61400 W HE Redundant Power Supply2All models 88Y7431A2A7900 W Power Supply2-88Y7433A2EA System x 4S- 750W High Efficiency -48 V DC Power Supply2-88Y7367A2A0Power Interposer for Redundant Power Supply1*-* The power interposer is not needed if the processor and memory expansion tray (88Y7365) is installed. Each AC power supply ships standard with one 2.8 m C13 - C14 power cord.Two installed 1400 W power supplies form a redundant pair. Under extreme configurations, it may be possible to exceed 1400 W DC output. If this condition exists and a power supply fails, the server caps power at 1400 W until the second power supply is back online.Integrated virtualizationThe server supports VMware ESXi installed on a USB memory key. The key is installed in a USB socket inside the server. The following table lists the virtualization options.Table 20. Virtualization optionsPart number Featurecode Description Maximumsupported41Y8298A2G0Blank USB Memory Key for VMware ESXi Downloads1 41Y8300A2VC USB Memory Key for VMware ESXi 5.01 41Y8307A383USB Memory Key for VMware ESXi 5.0 Update 11 41Y8311A2R3USB Memory Key for VMware ESXi 5.11 41Y8382A4WZ USB Memory Key for VMware ESXi 5.1 Update 11 41Y8385A584USB Memory Key for VMware ESXi 5.51Remote managementExternal backup unitsThe following table lists the external backup options that are offered by Lenovo. Table 24. External backup optionsPart number DescriptionExternal RDX USB drives4T27A10725ThinkSystem RDX External USB 3.0 DockExternal SAS tape backup drives6160S7E IBM TS2270 Tape Drive Model H7S6160S8E IBM TS2280 Tape Drive Model H8S6160S9E IBM TS2290 Tape Drive Model H9SExternal SAS tape backup autoloaders6171S7R IBM TS2900 Tape Autoloader w/LTO7 HH SAS6171S8R IBM TS2900 Tape Autoloader w/LTO8 HH SAS6171S9R IBM TS2900 Tape Autoloader w/LTO9 HH SASExternal tape backup libraries6741A1F IBM TS4300 3U Tape Library-Base Unit6741A3F IBM TS4300 3U Tape Library-Expansion UnitFull High 8 Gb Fibre Channel for TS430001KP938LTO 7 FH Fibre Channel Drive01KP954LTO 8 FH Fibre Channel Drive02JH837LTO 9 FH Fibre Channel DriveHalf High 8 Gb Fibre Channel for TS430001KP936LTO 7 HH Fibre Channel Drive01KP952LTO 8 HH Fibre Channel Drive02JH835LTO 9 HH Fibre Channel DriveHalf High 6 Gb SAS for TS430001KP937LTO 7 HH SAS Drive01KP953LTO 8 HH SAS Drive02JH836LTO 9 HH SAS DriveFor more information, see the list of Product Guides in the Backup units category: https:///servers/options/backupTop-of-rack Ethernet switches00YJ777ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y 00YJ778AU000U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y 0U Switched and Monitored PDUs00YJ783AU040U 12 C13/12 C19 Switched and Monitored48A 3 Phase PDUN N Y N N N Y N N Y Y Y N 00YJ781AU030U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDUN N Y N Y N Y N N Y Y Y N 00YJ782AU020U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDUY Y Y Y Y Y Y Y Y N Y N Y 00YJ780AU010U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDUY Y Y Y Y Y Y Y Y N Y N Y1U Switched and Monitored PDUs 4PU7A81117BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETLN N N N N N N N N N N Y N 4PU7A77467BLC41U 18 C19/C13 Switched and Monitored 80A 3P Delta PDUN N N N N N N N N Y N Y N 4PU7A77469BLC61U 12 C19/C13 switched and monitored 60A 3P Delta PDUN N N N N N N N N N N Y N 4PU7A77468BLC51U 12 C19/C13 switched and monitored 32A 3P WYE PDUY Y Y Y Y Y Y Y Y N Y Y Y 4PU7A81118BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CEY Y Y Y Y Y Y Y Y N Y N Y 46M400258961U 9 C19/3 C13 Switched and Monitored DPI PDUY Y Y Y Y Y Y Y Y Y Y Y Y 46M400458941U 12 C13 Switched and Monitored DPI PDUY Y Y Y Y Y Y Y Y Y Y Y Y46M400358971U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDUY Y Y Y Y Y Y Y Y Y Y Y Y 46M400558951U 12 C13 Switched and Monitored 60A 3Phase PDUY Y Y Y Y Y Y Y Y Y Y Y Y1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)71763NU 6051Ultra Density Enterprise C19/C13 PDU 60A/208V/3PHN N Y N N N N N N Y Y Y N 71762NX6091Ultra Density Enterprise C19/C13 PDU ModuleY Y Y Y Y Y Y Y Y Y Y Y Y1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)39M28166030DPI C13 Enterprise PDU Plus Module (WW)Y Y Y Y Y Y Y Y Y Y Y Y Y 39Y89416010DPI C13 Enterprise PDU Module (WW)Y Y Y Y Y Y Y Y Y Y Y Y Y 1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)39Y89486060DPI C19 Enterprise PDU Module (WW)Y Y Y Y Y Y Y Y Y Y Y Y Y 39Y89236061DPI Three-phase 60A/208V C19 Enterprise PDU (US)N N Y N N N Y N N N Y Y N1U Front-end PDUs (3x IEC 320 C19 outlets)Part number Feature code Description A N ZA S E AB r a z i E E T M E A R UC I W E H T K I ND I A J A P A L AN A P R C39Y89386002DPI Single-phase 30A/120V Front-end PDU(US)Y Y Y Y Y Y Y Y Y Y Y Y Y 39Y89396003DPI Single-phase 30A/208V Front-end PDU (US)Y Y Y Y Y Y Y Y Y Y Y Y Y 39Y89346005DPI Single-phase 32A/230V Front-end PDU (International)Y Y Y Y Y Y Y Y Y Y Y Y Y 39Y89406004DPI Single-phase 60A/208V Front-end PDU (US)Y N Y Y Y Y Y N N Y Y Y N 39Y89356006DPI Single-phase 63A/230V Front-end PDU (International)Y Y Y Y Y Y Y Y Y Y Y Y Y1U NEMA PDUs (6x NEMA 5-15R outlets)39Y89055900DPI 100-127V NEMA PDUY Y Y Y Y Y Y Y Y Y Y Y Y Line cords for 1U PDUs that ship without a line cord40K96116504 4.3m, 32A/380-415V, EPDU/IEC 3093P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y 40K96126502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line CordY Y Y Y Y Y Y Y Y Y Y Y Y 40K96136503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line CordY Y Y Y Y Y Y Y Y Y Y Y Y 40K96146500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line CordY Y Y Y Y Y Y Y Y Y Y Y Y 40K96156501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line CordN N Y N N N Y N N Y Y Y N 40K96176505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y 40K961865064.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line CordY Y Y Y Y Y Y Y Y Y Y Y YPart number Feature code Description For more information, see the Lenovo Press documents in the PDU category:https:///servers/options/pduRack cabinetsA N ZA S E AB r a z i E E T M E A R UC I W E H T K I ND I A J A P A L AN A P R CRack cabinetsThe server supports the rack cabinets listed in the following table.Table 28. Rack cabinetsPart number Description201886X11U Office Enablement Kit93072PX25U Static S2 Standard Rack93072RX25U Standard Rack93074RX42U Standard Rack93074XX42U Standard Rack Extension93084EX42U Enterprise Expansion Rack93084PX42U Enterprise Rack93604EX42U 1200 mm Deep Dynamic Expansion Rack93604PX42U 1200 mm Deep Dynamic Rack93614EX42U 1200 mm Deep Static Expansion Rack93614PX42U 1200 mm Deep Static Rack93624EX47U 1200 mm Deep Static Expansion Rack93624PX47U 1200 mm Deep Static Rack99564RX S2 42U Dynamic Standard Rack99564XX S2 42U Dynamic Standard Expansion RackFor more information, see the list of Product Guides in the Rack cabinets category: https:///servers/options/racksKVM console optionsThe following table lists the supported KVM consoles, keyboards, and KVM switches. Table 29. Console keyboardsPart number DescriptionConsoles17238BX1U 18.5" Standard Console (without keyboard)Console keyboards00MW310Lenovo UltraNav Keyboard USB - US Eng46W6713Keyboard w/ Int. Pointing Device USB - Arabic 253 RoHS v246W6714Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v246W6715Keyboard w/ Int. Pointing Device USB - Chinese/US 467 RoHS v246W6716Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v246W6717Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v246W6718Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v246W6719Keyboard w/ Int. Pointing Device USB - French 189 RoHS v246W6720Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v246W6721Keyboard w/ Int. Pointing Device USB - German 129 RoHS v246W6722Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2Part number Description46W6723Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v246W6724Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v246W6725Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v246W6726Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v246W6727Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v246W6728Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v246W6729Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v246W6730Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v246W6731Keyboard w/ Int. Pointing Device USB - Portuguese 163 RoHS v246W6732Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v246W6733Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v246W6734Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v246W6735Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v246W6736Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v246W6737Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v246W6738Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v246W6739Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v246W6740Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v246W6741Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2Console switches1754D2X Global 4x2x32 Console Manager (GCM32)1754D1X Global 2x2x16 Console Manager (GCM16)1754A2X Local 2x16 Console Manager (LCM16)1754A1X Local 1x8 Console Manager (LCM8)Console switch cables43V6147Single Cable USB Conversion Option (UCO)39M2895USB Conversion Option (4 Pack UCO)46M5383Virtual Media Conversion Option Gen2 (VCO2)46M5382Serial Conversion Option (SCO)For more information, see the list of Product Guides in the KVM Switches and Consoles category: /servers/options/kvmRelated publications and linksTrademarksLenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web athttps:///us/en/legal/copytrade/.The following terms are trademarks of Lenovo in the United States, other countries, or both:Lenovo®Lenovo ServicesRackSwitchServeRAIDServerGuideServerProven®System x®ThinkSystem®UltraNav®eX5eXFlashThe following terms are trademarks of other companies:Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.Linux® is the trademark of Linus Torvalds in the U.S. and other countries.Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.Other company, product, or service names may be trademarks or service marks of others.。
May be covered by one or more of the following: U.S. Patents #4538297, 4647876, 4696044, 4745309, 4881047, 4893099, 5124657, 5263091, 5268527, 5319713, 5333201, 5402498 and 5493617.Other patents pending. Foreign patents pending.Instruction ManualYour Reaction Dynamic Filter pedal has been tested and complies with the following Standards and Directives as set forth by the European Union:Council Directive(s): 89/336/EEC ElectromagneticCompatibilityStandard(s): EN55013, EN50082-1This means that this product has been designed to meet stringent guidelines on how much RF energy it can emit, and that it should be immune from other sources of interference when properly used. Improper use of this equipment could result in increased RF emissions, which may or may not interfere with other electronic products.To insure against this possibility, always use good shielded cables for all audio input and output connections. This will help insure compliance with the Directive(s).For more information about other Rocktron products, please see your local dealer or one of our importers closest to you (listed on the Rocktron website ().Read all instructions contained in this manual.Keep these instructions Heed all warnings Follow all instructions.Do not use this apparatus near water.Clean with dry clothCopyright © 2009 GHS Corporation All Rights Reserved.ComplianceDo not block any ventilation openings (if applicable). Install in accordance with the manufacturer’s instructions.Do not install near any heat sources such as radiators, heat registers, stoves or other ap-paratus (including amplifiers) that produce heat. This product is not equipped with a plug or cable. This pedal runs on a 9 V olt Battery, if a 9V olt DC adapter is the used please follow adapter manufacturer’s operation instructions.Only used attachments/accessories specified by the manufacturer.Do not use this product with any case, stand tripod, bracket or table that is not specified by the manufacturer. Insure that the case, stand, tripod, bracket etc. is properly adjusted and setup (follow all instructions). Extra care and caution should be taken to avoid tip over and injury.Unplug this apparatus during lightening storms or when unused during long periods of time.Refer all service to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply or plug is damaged, liquid has been spilled or objects have fallen into the apparatus or if the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped.DO NOT ATTEMPT TO SERVICE THIS EQUIPMENT. QUALIFIED PERSONNEL SHOULD SERVICE THIS EQUIPMENT ONLY . DO NOT MAKE ANY INTERNAL ADJUSTMENTS OR ADDITIONS TO THIS EQUIPMENT AT ANY TIME OR TAMPER WITH INTERNAL ELECTRONIC COMPONENTS AT ANY TIME. FAILURE TO FOL-LOW THESE INSTRUCTIONS MAY VOID THE WARRANTY OF THIS EQUIPMENT AS WELL AS CAUSING A SHOCK HAZARD.OPERATING TEMPERATUREDo not expose this unit to excessive heat. This unit is designed to operate between 32 F and 104 F (0 C and 40 C). This unit may not function properly under extreme temperatures.PrecautionsIntroduction:Are you searching for something new to add to your setup and spice things up? Are you a guitar player who wants to add a crazy, phasey and downright out of sight twisted effect to your pedal arsenal. Maybe you are a bass player searching for something that will give you that funk with lots of punch? Rocktron aims to please that eclectic wild streak deep inside every musician with the Reaction Dynamic Filter.The Reaction Dynamic Filter utilizes harmonic phase shifting effect that sweeps the frequency spectrum from high to low providing a unique one of a kind sound. Since a dynamic filter is triggered by your pick attack, the harder you pick the string, the higher the resonant frequencies become. The SENSITIVITY control determines the frequency at which the filter will begin its phase shifting.For bass players, lower SENSITIVITY settings provide a funky walking talking swanky arpeggio effect tracking your pick dynamics to produce a smooth and cool feel. Turn on the DISTORTION to make it growl.For guitar players higher SENSITIVITY settings provide a more expressive “zipper” effect that is ideally suited for lead breaks. Play around with it and you will find that there are a lot of possibilities, all the way to a searing razor edge off the hook vibe controlled by your pick attack!Introduction continued....:LEVEL control determines the output level of the effect. We have also included a DISTORTION button to give you a little more “dirt” when playing.Rocktron’s Reaction Series pedals are built into a rugged metal slim form factor chassis, taking up as little space as possible on your pedal board. The Reaction Dynamic Filter is a TRUE BYPASS pedal: when you turn it off…it is out of your signal path!The Reaction Dynamic Filter can be placed in the signal chain before or after a distortion. We recommend placing it after. If using multiple pedals such as delays and other modulation effects, try the Reaction Dynamic Filter in different parts of the signal chain until you find the sound you personally prefer.Rocktron’s Reaction Series pedals are built into a rugged metal slim form factor chassis, taking up as little space as possible on your pedal board. The Reaction Dynamic Filter is a TRUE BYPASS pedal: when you turn it off…it is out of your signal path!The footswitch on the Reaction Dynamic Filter controls On/Off status as shown by the LED indicator. Reaction stomp boxes run on a 9V Alkaline battery, or may also be powered by Rocktron’s DC OnTap Universal Power Supply adaptor.DescriptionsSENSITIVITY Control - This control determines level of attack to cause the effect to activate.DISTORTION Switch - This switch adds distortion to the effect. When the switch is in the distortion is on. When out, the distortion is off.9VDC Input - This input jack provides 9VDC power to the pedal from the Rocktron DC OnTap 9V power supply (sold seperately).LEVEL Control - This control determines the volume of the effect summed to the output.ON/OFF Leds - These LEDs shows if the pedal is on or off. When the LED is lit the pedal is on. When the LED is not lit the pedal is off.BATTERY COMPARTMENT and COVER The 9V battery can be found in this compartment.123456INPUT Jack - Using a standard 1/4” guitar cable, plug your guitar into this jack.THUMB SCREWS for Battery Compartment. Unscrew these thunb screws to access the bat-tery compartment.FOOTSWITCH - Use this switch to turn on or off the pedal. The On/Off Led will show you if the pedal is on or off.OUTPUT Jack - Using a standard 1/4” guitar cable you can plug in another pedal from this jack or plug directly into your amplifier.78910Typical ConnectionSpecificationsHow to change the battery:To change the battery, remove the thumb screws on the top of the pedal and remove the battery com-partment cover. Remove the old battery and replace it with a new 9V Alkaline battery. Replace battery in the same area as the old battery was located. Place the battery compartment cover on the pedal and re-insert the thumb screws.Save yourself tons of money in batteries by using the Rocktron DC OnTap Universal Power Supply to power this pedal (sold seperately). The Rock-tron DC OnTap provides a constant flow of power to the pedal, unlike a battery that will degrade over time. The Rocktron DC OnTap Univeral Power Supply can also power up to 20 pedals and can be used with both 110V and 220V power sources.Check, for more information on the DC OnTap and where to purchase.Rocktron - A Division of GHS Corporation 2813 Wilber AveBattle Creek MI 49037USA*****************tel: 1-269-968-3351rev. 7-27-092009.1。