思科Catalyst 65系列交换机VSS虚拟交换系统配置详解
- 格式:doc
- 大小:70.00 KB
- 文档页数:6
思科VSS65配置步骤一、将2台VSS65从单机箱模式切换到虚拟机箱模式基本步骤:1.分别在交换机1、2上配置SSO高可用性协议:2.配置虚拟交换机的域(Virtual Switch Domain and Switch Numbers)3.配置两台交换机之间的VSL 端口。
(利用引擎上的2个万兆光口进行连接)4.转换机箱变成虚拟交换机模式详细配置:1.分别在交换机1、2上配置SSO高可用性协议:SWITCH1:CommandPurposeStep 1Switch-1(config)# redundancyEnters redundancy configuration mode.Step 2Switch-1(config-red)# mode ssoConfigures SSO. When this command is entered, the redundant supervisor engine is reloaded and begins to work in SSO mode.Step 3Switch-1(config-red)# exitExits redundancy configuration mode.Step 4Switch-1# show running-configVerifies that SSO are configured and enabled.Step 5Switch-1# show redundancy statesDisplays the operating redundancy mode.SWITCH2:CommandPurposeStep 1Switch-2(config)# redundancyEnters redundancy configuration mode.Step 2Switch-2(config-red)# mode ssoConfigures SSO. When this command is entered, the redundant supervisor engine is reloaded and begins to work in SSO mode.Step 3Switch-2(config-red)# exitExits redundancy configuration mode.Step 4Switch-2# show running-configVerifies that SSO are configured and enabled.Step 5Switch-2# show redundancy statesDisplays the operating redundancy mode.2.配置虚拟交换机的域(Virtual Switch Domain and Switch Numbers)SWITCH1:CommandPurposeStep 1Switch-1(config)# switch virtual domain 100Configures the virtual switch domain on Chassis A.(id可自定义)Step 2Switch-1(config-vs-domain)# switch 1Configures Chassis A as virtual switch number 1.Step 3Switch-1(config-vs-domain)# exitExits config-vs-domain.SWITCH2:CommandPurposeStep 1Switch-2(config)# switch virtual domain 100Configures the virtual switch domain on Chassis B. (id可自定义)Step 2Switch-2(config-vs-domain)# switch 2Configures Chassis B as virtual switch number 2.Step 3Switch-2(config-vs-domain)# exitExits config-vs-domain.3.配置两台交换机之间的VSL 端口。
思科虚拟交换系统VSS思科虚拟交换系统VSS就是一种典型的网络虚拟化技术,它可以实现将多台思科交换机虚拟成单台交换机,使设备可用的端口数量、转发能力、性能规格都倍增。
例如,它可将两台物理的Cisco catalyst 6500系列交换机整合成为一台单一逻辑上的虚拟交换机,从而可将系统带宽容量扩展到1.4Tbps。
虚拟交换系统vss而想要启用VSS技术,还需要通过一条特殊的链路来绑定两个机架成为一个虚拟的交换系统,这个特殊的链路称之为虚拟交换机链路(Virtual Switch Link,即VSL)。
VSL承载特殊的控制信息并使用一个头部封装每个数据帧穿过这条链路。
在VSS之中,其中一个机箱指定为活跃交换机,另一台被指定为备份交换机。
而所有的控制层面的功能,包括管理(SNMP,Telnet,SSH等),二层协议(BPDU,PDUs,LACP等),三层协议(路由协议等),以及软件数据等,都是由活跃交换机的引擎进行管理。
此外,VSS技术还使用机箱间NSF/SSO作为两台机箱间的主要高可用性机制,当一个虚拟交换机成员发生故障时,网络中无需进行协议重收敛,接入层或核心层交换机将继续转发流量,因为它们只会检测出EtherChannel捆绑中有一个链路故障。
而在传统模式中,一台交换机发生故障就会导致STP/HSRP和路由协议等多个控制协议进行收敛,相比之下,VSS将多台设备虚拟化成一台设备,协议需要计算量则大为减少。
凭借VSS技术,不仅实现了交换机的简易管理,同时提高了运营效率。
网络管理员仅需登录虚拟化设备,即可直接管理虚拟化为一体的所有设备,真正简化了网络管理。
而需要特别说明的是,目前VSS技术仅适用于Cisco 6500系列、Cisco 7600系列和Nexus 7000系列等高端机型上。
配置示例1.具体配置:6509-1配置:(1)制定switch 1,配置优先级switch virtual domain 100switch 1switch 1 priority 110switch 2 priority 100mac-address use-virtual(2)配置VSLinterface port-channel 1no shutswitch virtual link 1exitinterface ten 5/4no shutchannel-group 1 mode onexitinterface ten 5/5no shutchannel-group 1 mode onexit(3)特权模式下执行转换命令switch convert mode virtual输入“yes”6509-2配置:(1)制定switch 2,配置优先级switch virtual domain 100switch 2switch 1 priority 110switch 2 priority 100mac-address use-virtual(2)配置VSLinterface port-channel 2no shutswitch virtual link 2exitinterface range ten 5/4no shutchannel-group 2 mode onexitinterface range ten 5/5no shutchannel-group 2 mode onexit(3)特权模式下执行转换命令switch convert mode virtual输入“yes”完成上述配置后设备会自动重启,形成VSS。
Cisco6509-VSS配置VSS配置一、在核心交换机65-1上配置VSS(1)将核心交换机65-1 上与65-2 相连的接口TenGigabitEthernet5/4 和TenGigabitEthernet5/5配置为EtherChannel:switch-1(config)#interface range tenGigabitEthernet 5/4 - 5 switch-1(config-if-range)#channel-group 10 mode onswitch-1(config-if-range)#no shutdown% Range command terminated because it failed on TenGigabitEthernet5/4switch-1(config-if-range)#exit(2)配置VSS域名与VSS主机号:switch-1(config)#switch virtual domain 100Domain ID 100 config will take effect onlyafter the exec command 'switch convert mode virtual' is issuedswitch-1(config-vs-domain)#switch 1switch-1(config-vs-domain)#switch 1 priority 200switch-1(config-vs-domain)#switch 1 preemptPlease note that Preempt configuration will make the ACTIVE switch with lower priority to reload forcefully when preempt timer expiresswitch-1(config-vs-domain)#exit说明:配置VSS 的域名为100,范围为1-255,两台交换机必须相同;配置VSS的主机号码为1,必须一台为1,另一台为2;并配置VSS 优先级为200,默认为100,数字越大,优先级越高,便能成为主VSS 交换机。
思科虚拟交换系统(VSS)Q. 什么是虚拟交换系统(VSS)?A.VSS是一种网络系统虚拟化技术,将两台Cisco® Catalyst® 6500系列交换机组合为单一虚拟交换机,从而提高运营效率、增强不间断通信,并将系统带宽容量扩展到1.4Tbps。
在初始阶段,VSS将使两台物理Cisco Catalyst 6500系列交换机作为单一逻辑虚拟交换机运行,称为虚拟交换系统 1440(VSS1440)。
(参见图1)图1虚拟交换系统 1440与传统网络设计的比较Q. 什么是VSS1440?A.VSS1440指由两台采用Virtual Switching Supervisor 720-10GE 的Cisco Catalyst 6500系列交换机构成的VSS。
在一个VSS中,同时激活这两个机箱的数据平面和交换阵列,各支持720Gbps管理引擎,每VSS共1400-Gbps交换容量。
只有其中一个虚拟交换机成员有激活的控制平面。
这两个机箱通过机箱间状态切换(SSO)机制和不间断转发(NSF)保持同步,即使某个管理引擎或机箱发生了故障,也能提供不间断通信。
Q. VSS有什么优势?A.与传统的L2/L3网络设计相比,VSS提供了出色优势,可分为以下四个大类:1.VSS通过简化网络提高了运营效率,将交换机管理开销降低至少50%。
o为Cisco Catalyst 6500虚拟交换机提供单管理点、IP 地址和路由实例- 管理单一配置文件和节点。
无需用相同策略配置冗余交换机两次。
- 每VLAN只需一个网关IP地址,而不必像现在这样每VLAN使用三个IP地址。
- 无需再使用HSRP、VRRP和GLBP。
- 能使用CiscoWorks LAN Management System (LMS) 3.0来将Cisco Catalyst 6500虚拟交换机作为单一实体加以集中管理。
o多机箱EtherChannel®(MEC)是一种L2多路径技术,创建了简化的无环路技术,不再采用生成树协议,同时仍能激活以严格防御用户误配置。
这份文档我只是总结性质的,大部分还是其他人写的,感谢为这份文档付出努力的人北京-小小Cisco Catalyst 6500 VSS系统概述1)Cisco Catalyst 6500系列虚拟交换系统1440初始版本可以整合两台物理的Cisco catalyst 6500系列交换机成为一台单一逻辑上的虚拟交换机。
图5介绍了VSS的工作模式,两台Cisco Catalyst 6509交换机配置虚拟交换系统后,就可以当作一台单独的Cisco Catalyst 6509交换机进行管理。
图 5. Cisco Virtual Switching System启用虚拟交换系统技术是通过一条特殊的链路来绑定两个机架成为一个虚拟的交换系统,这个特殊的链路称之为虚拟交换机链路(Virtual Switch Link,VSL)。
VSL承载特殊的控制信息并使用一个头部封装每个数据帧穿过这条链路。
2) Cisco Catalyst 6500 虚拟交换系统1440架构体系Cisco Catalyst 6500虚拟交换系统允许合并两个交换机成为一台无论是从网络控制层面和管理视图上在网络上都是一个单独的设备实体。
对于邻居,这个虚拟交换系统相当于一台单独的交换机或者路由器。
在虚拟交换系统中,其中一个机箱指定为活跃交换机,另一台被指定为备份虚拟交换机。
所有的控制层面的功能,包括管理(SNMP,Telnet,SSH等),二层协议(BPDU,PDUs,LACP等),三层协议(路由协议等),以及软件数据等,都是由活跃交换机的引擎进行管理。
在活跃交换机上的超级引擎与备份交换机引擎上的PFC负责响应处理硬件转发信息到分布式转发卡(DFC)之上贯穿整个虚拟交换系统。
图6. Components of Cisco Virtual Switching System从数据层面和流量转发图上来看,在虚拟交换系统1440中的所有交换机都参与流量转发。
在活跃虚拟交换机超级引擎上的PFC执行为所有进入活跃虚拟交换机的流量转发查找,位于备份状态的交换机引擎上的PFC执行为所有进入备份状态交换机流量转发查找。