e+h超声波流量计参数
e+h(Endress+Hauser,艾默生汉尼斯)的超声波流量计参数如下:
1. 测量范围:最小测量范围为0.15m/s,最大测量范围为
±40m/s。
2. 测量精度:标准精度为±0.5%(关于流体的速度和温度变化),高精度为±0.25%。
3. 测量介质:适用于各种液体,包括腐蚀性液体和带有杂质的液体。
4. 工作温度范围:-40°C到+160°C。
5. 输出信号:可选择4-20mA输出或者脉冲输出。
6. 液体压力:最大可承受16MPa的压力。
7. 电源:DC 24V,±10%。
8. 温度补偿:自动进行温度补偿。
9. 显示屏:LCD显示屏,可显示瞬时流量、累积流量和供电状态。
10. 通信接口:RS485接口,可实现MODBUS协议通讯。
以上就是e+h超声波流量计的主要参数介绍。
Ultrasonic FlowmeterModel Alsonic-FXMeasuring Principle :Transit time differenceKeypad :16 Key with tactile action Pipe Size:S Type : 15 mm ~ 100 mm (1/2" ~ 4")Response Time:Less than 1 second:M Type : 50 mm ~ 700 mm (2" ~ 28")Flow Velocity:0.01 ~ +/- 32 m/s:L Type : 300 mm ~ 6000 mm (12" ~ 240")Resolution :0.0001 m/sPipe Material:Cast Iron, Stainless Steel, Ductle Iron Ambient Temperature :-20 ~ +50 CCopper, PVC, Aluminum, AsbestosMounting:wall mounting, panel, local Fiberglass… etc.Max. Cable Length :150 M Liner Material:Tar Epoxy, Rubber, Mortar, Polypropylene,Power Consumption : Less than 2W Polystryal, Ploystryene, Polyester, Ebonite,Power Supply :90 ~ 260Vac 50/60 HzPolyethylene, Teflon… etc.Data Storage:Operation parameters and totalization Display:2 Line LCD with illumination.date are stored by EEPROM for more Flowrate :5 digit with decimal pointthan 10 yearsTotalizer :8 digit, Forward, Reverse & Net values.Output :4-20 mA or 0-20 mA Engineer Unit :M3, Liter, US Gallon, Imperial Gallon,Pulse Output :1- 9999 HzMillion Gallon, Cubic Feet, US Barrels,Data Logger:64 data include flowrate, totalizer,Imperial Barrels, Oil Barrel.time, date.Time Unit :Second, Minute, Hour, Day.Alarm:High/Low with buzzer Other :Velocity, Date, Time, Signal condition.Communication :RS-232Accuracy:+/- 1% ~ +/- 2% of reading(0.5 ~ 30 m/s)Dimension :235 * 205 * 95 mm :+/- 0.5% of reading (online calibration)Weight :1.5 KgRepeatability:+/-0.2% of readingProtectionConverter :IP65Sensor :IP68(Submersible)SmartMeasurement.Page 12960 Polk St. Suite 12, San Francisco, CA 94109 USA URL : LDD1200165125200185145Measuring TapeStretcher CableASize:180×170×56mm Size:165×160×80mmSize:96×96×129mmInput:3 channel 4-20mA analog input, 2 channel resistance signal inputOutput:Isolation RS232/RS485 output, 2 channel isolation OCT output。
超声波流量计介绍FDT-21系列(欧米茄)•精度为1%•重复性为0.2%•正向流量、反向流量和净累加流量•4行LCD显示屏•钳式传感器•RS232输出FDT-21超声波流量计专门用来测量全封闭式管路中液体的流量。
它是一种手持式测量系统,其安装和使用都很方便。
FDT-21依据所测量的超声波渡越时间差异工作,它通过测量脉冲从一个传感器传输到另一个传感器的时间来计算流量。
与相反方向的流动相比,相同方向的流动到另一个传感器的用时要少一些。
电声传感器发射和接收的短超声波脉冲穿过管路中的液体。
传感器垂直安放于被测量管路两端。
传感器用夹钳固定到管路上。
显示屏将迅速显示流量。
FDT-21流量计可用于金属、塑料以及橡胶管路。
规格:精度:读数的±1% >(0.2m/s) 0.6 ft/s重复性:0.2%线性度:0.5%响应时间:0 ~ 999 seconds(用户可配置)流速:(±0.01 ~ 30 m/s) ±0.03 ~ 105 ft/s(双向)温度范围:标配:0 ~ 70ºC (32 ~ 158ºF)带有高温传感器:0 ~ 160ºC (32 ~ 320ºF)管路尺寸:DN 20 ~ 100 mm (0.75 ~ 4")(标配)[最大可达DN 6000 mm (236"),带有可选传感器]传感器频率:1 MHz流量单位(用户可配置):米、英尺、立方米、立方英尺、美制加仑、油桶、美制液桶、英制液桶、美制百万加仑累加器:可用于正向流量、反向流量及净流量的7位数字累加流量显示液体类型:大部分液体,包括净水、海水、废水、化工液体、油、原油、酒精、啤酒等等悬浮液浓度:≤20,000 ppm(可以包含极少量气泡)管路材质:所有金属材料、大部分塑料及玻璃纤维安全性:可编程锁码显示屏:4 x 16英文字母通信方式:RS232C(波特率范围为75 ~115,200 bps)传感器电缆长度:5 m (15')工作电源:3节"AAA"镍氢内置电池(内含),带有90 ~230 Vac充电器,充满电可用12小时以上。
e-mail:**************For latest product manuals:Shop online atSeries FTB–1400-MD-LP FTB–1400-SD-LP FTB–1400-RD-LPFlow Monitor - Simplified VersionServicing North America:Servicing Europe:U.S.A.:Omega Engineering, Inc., One Omega Drive, P.O. Box 4047ISO 9001 Certified Stamford, CT 06907-0047Toll-Free: 1-800-826-6342Tel: (203) 359-1660FAX: (203) 359-7700e-mail:**************Canada:976 BergarLaval (Quebec), Canada H7L 5A1Toll-Free: 1-800-826-6342TEL: (514) 856-6928FAX: (514) 856-6886e-mail:*************For immediate technical or application assistance:U.S.A. and Canada:Sales Service: 1-800-826-6342/1-800-TC-OMEGA ®Customer Service: 1-800-622-2378/1-800-622-BEST ®Engineering Service: 1-800-872-9436/1-800-USA-WHEN ®Mexico:En Español: 001 (203) 359-7803FAX: (001) 203-359-7807**************.mxe-mail:*****************Benelux:Managed by the United Kingdom Office Toll-Free: 0800 099 3344TEL: +31 20 347 21 21FAX: +31 20 643 46 43e-mail:**************Czech Republic:Frystatska 184733 01 Karviná, Czech RepublicToll-Free: 0800-1-66342TEL: +420-59-6311899FAX: +420-59-6311114e-mail:*****************France:Managed by the United Kingdom OfficeToll-Free: 0800 466 342TEL: +33 (0) 161 37 29 00FAX: +33 (0) 130 57 54 27e-mail:**************Germany/Austria:Daimlerstrasse 26D-75392 Deckenpfronn, GermanyToll-Free************TEL: +49 (0) 7059 9398-0FAX: +49 (0) 7056 9398-29e-mail:*************United Kingdom:OMEGA Engineering Ltd.ISO 9001 Certified One Omega Drive, River Bend Technology Centre, NorthbankIrlam, Manchester M44 5BD EnglandToll-Free: 0800-488-488TEL: +44 (0)161 777-6611FAX: +44 (0)161 777-6622e-mail:**************.uk OMEGAnet ® Online Service Internet e-mail **************It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.WARNING: These products are not designed for use in, and should not be used for, human applications.CONTENTSINTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 OPERATING THE MONITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 BASIC PROGRAMMING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 FTB–1400 Simplified 4-20 mA Programming . . . . . . . . . . . . . . . . . . . . . . . . .10 ADDITIONAL INPUT OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 DEFAULT K-FACTOR VALUES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 PART NUMBERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183INTRODUCTIONThe FTB–1400 Flow Monitor is a state-of-the-art, digital signal processing flow monitor, designed to provide the user with exceptional flexibility at a very affordable price . Though designed for use with Omega FTB–1400 flow meters, this display can be used with almost any flow meter producing a low amplitude AC output or contact closure signal(s) .This flow monitor is capable of accepting a low-level frequency input for calculating flow rate and total . These calculations can then be displayed in the desired units of measurement . All FTB–1400 flow monitors come pre-calibrated, from the factory, if ordered with an Omega FTB–1400 Flow Meter . If required, however, it can easily be re-configured in the field . The monitor’s large 8 digit by .75" numeric liquid crystal display makes extend-ed range viewing practical . The second 8 digit by .38" alphanumeric display provides for selectable units viewing in run mode and prompts for vari-ables in program mode . Finally, the user can choose between displaying rate, total, or alternating between both rate and total .Figure 1: Flow Monitor Face4FEATURES• Displays Rate and/or Total• Large 0 .75 Inch, 8 Digit Display for Easy Viewing• Simple, Front Panel Programming• Various Mounting Styles Available• NEMA 4X Suitable for Outdoor Mounting• Intrinsically Safe• Microprocessor Based, Low Power Components• 4-20 mA Loop Powered• Automatic Decimal Point Locating• Lead Zero Blinking• Surface Mount Technology Use Throughout5SPECIFICATIONSPower Supply:4-20 mA loop powerPower Consumption:25 mA (maximum)Alphanumeric Rate and Total Display:8 digit, .75" high numeric display8 character, .38" high alphanumeric displayFixed or toggle modes of operation for flow rate and totalizer display Pulsed Output Signal:Outputs one pulse for each increment of the least significanttotalizer digitMax . Voltage: 30 VdcPulse Type: Opto-Isolated open collector transistorPulseWidthONState:***************************** Magnetic Pick-up Inputs:Frequency Range: 0 to 3500 HzTrigger Sensitivity: 30 mV p-pOver Voltage Protected: ±30 VDCFrequency Measurement Accuracy: ±0 .1%Temperature Drift: 50 ppm / ºC (max)Transient Overvoltages: Category 3, in accordance with IEC664 Pollution Degree: 2, in accordance with IEC664Mounting Classification:Meter Mount: NEMA 4X EnclosureRemote Mount: NEMA 4X EnclosureSwivel Mount: NEMA 4X EnclosureEnvironmental:Operating Temperature: -22 ºF to +158 ºF (-30 ºC to +70 ºC)Humidity: 0-90% Non-condensingUnits of Measure:Gallons, Oil Barrels, Liters, Cubic Meters, MGal, Cubic FT, MCF, MMCF Megltrs, Acre FT, Liq . Barrels, LBS, KGSTime Intervals: Day, Hour, Minute, Second6OPERATING THE MONITORThe monitor has two modes of operation referred to as the RUN mode and the PROGRAM mode . Both the run mode and the program mode display screen enunciators confirming the state of the monitor . A quick glance at the lower left hand corner of the LCD screen will confirm operating status . Normal operation will be in the RUN mode . To access the program mode, press the MENU button until the first programming screen is displayed . After programming the display with the necessary information, a lock out feature can be turned on to prevent unauthorized access or changing the meter’s setup parameters .BASIC PROGRAMMING MODEKeys:MENU – Switch between RUN and PROGRAM modesUP Arrow – Scrolls through programming sub-menus in forwarddirection and increments numeric variablesRIGHT Arrow – Scrolls through programming sub-menus in reverse direction and moves the active digit to the rightENTER – Used to enter sub-menus, save programming informationand in the reset processIf your monitor was ordered with an Omega flow meter, the two compo-nents ship from the factory calibrated as a set . If the monitor is a replace-ment, the turbine’s K-factor has changed, or the monitor is being used with some other pulse generating device, programming will be necessary . PROGRAMMINGEach turbine flow meter is shipped with either a K-factor value or frequency data . If frequency data is provided, the data must be converted to a K-factor before programming . K-factor information, when supplied, can usually be found on the neck of the flow meter or stamped on the body . The K-factor represents the number of pulses per unit of volume . The K-factor will be needed to program the monitor .ENTER PRO GRAM MO DE – Change to program mode by press-ing the MENU button once . The mode indicator will change from RUN to PROGRAM .78ton once . The current meter size number will begin to flash . Using the arrow keys, scroll through the size choices until you find the bore size ofyour meter . Press ENTER once to save the meter size choice .Rate / Total DisplayAndProgrammingKeys Mode IndicatorAndProgramming ChoicesFigure 2: Flow Monitor ControlsENTER THE METER’S K-FACTOR UNIT – Directly after the METER size is selected, the display’s K-factor unit must be chosen . Use the UP arrow key to select your K-factor unit . For meters calibrated in gallons, use PUL/GAL (pulses per gallon); for meters calibrated in cubic meters, use PUL/M3 (pulses per cubic meter), etc . Press ENTER to save the K-factorunit and advance to the next parameter .SELECT THE RATE/TOTAL UNITS OF MEASURE – The monitor allows the choice of five common rate/total units . The monitor shows the rate/ total unit that the display is currently set for . If the current selection is correct, press the ENTER key once to advance to the next parameter . To change to an alternate unit, use the arrow keys to scroll to the desiredrate unit and press ENTER to save the choice .SELECT THE DISPLAY FUNCTION – The monitor can display RATE or TOTAL or alternate between BOTH rate and total . At the DISPLAY prompt, press the ENTER key once . The monitor now shows the display mode currently in effect . If the current selection is correct, press the ENTER key to advance to the next parameter . To change to an alternate display mode, use the ar-row keys to scroll to the desired display mode and press ENTER to save the choice .A TEST function is also available in the Display Function sub-menu . With the test function selected, the display acts like a frequency counter and displays the raw input frequency being supplied to the frequency input terminals . This is very useful when troubleshooting flow problems .9TOTALIZER PULSE OUTPUT – The pulse output parameter can be either enabled or disabled . When enabled this output generates 20 mS duration pulse for every time the least significant digit of the totalizer increments . The amplitude of the pulse is dependent on the voltage level of the supply connected to the pulse output and is limited to a maximum 30 VDC . FTB–1400 SIMPLIFIED 4-20 MA PROGRAMMINGFLOW 4mA SETTING – When the loop powered option is ordered, the flow rate that corresponds to 4mA must be set . Zero is default flow rate for this setting . If the current selection is correct, press the ENTER key once to advance to the next parameter . If adjustment is required, use the RIGHT arrow key to select the position of the number you wish to change . Then use the UP arrow key to increment the number . Once you have completed this step, press the ENTER key to advance to the next parameter .FLOW 20mA SETTING – The flow rate that corresponds to 20mA must be set next . The turbine meter’s maximum flow rate is the default value .If the current selection is correct, press the ENTER key once to advance to the next parameter . If adjustment is required, use the RIGHT arrow key to select the position of the number you wish to change . Then use the UP arrow key to increment the number . Once you have completed this step, press the ENTER key to advance to the next parameter .4-20mA CALIBRATIO N – When ordered with a 4-20mA option, this menu item allows the fine adjustment of the 4-20mA output . The 4mA setting is typically between 35 and 50 . To set the 4mA value, connect an ammeter in series with the loop power supply . At the 4mA OUT prompt, adjust the 4mA value to obtain a 4mA reading on the amme-ter . The UP arrow key increments the value and the RIGHT arrow key decrements the value . When a steady 4mA reading is obtained on the ammeter, press the ENTER key to lock in this value and move to the 20mA adjustment . The 20mA adjustment is performed using the same procedure as the 4mA adjustment .4-20mA TEST – The monitor contains a diagnostic routine that allows the simulation of mA values between 4 and 20 to check output track-ing . At the 4-20TEST prompt the arrow keys change the simulated mA output in increments of 1mA . The ammeter should track the simulated mA output . If a 4-20mA test in not necessary, pressing the ENTER key once will escape the testing at any time .1011Figure 3: Typical Ammeter ConnectionPASSWO RD – Password protection prevents unauthorized users fromchanging programming information . Initially, the password is set to all ze-ros . To change the password, simply enter any 4 digit code using the arrow keys as previously described to enter the password value . Pressing ENTER once will store the password and take you back to the RST PSWD screen .RST PSWD – The reset password screen allows the operator to enter any 4 digit code for the manual reset totals function .RESET TOTAL – To reset the monitor total display, in RUN mode press the MENU and ENTER simultaneously until TOTAL RST starts to flash . The TOTAL RST will stop flashing and the display will return to the RUN mode at the conclusion of the reset procedure .STORE TOTAL – The current total can be manually stored in the monitor’s flash memory . Press and hold the ENTER key for 2 seconds . The display will respond with a flashing TOTALSVD and then return to the RUN mode .AUTOMATIC STORE TOTAL – The monitor is equipped with a store total feature that works automatically, saving the current total to flash memory . The frequency of saves depends on the power supply option chosen .Loop Powered: Once every ten minutes . ADDITIONAL INPUT OPTIONSThe FTB–1400 Flow Monitor is capable of receiving magnetic pick-up input (small signal sine wave) or a contact closure input (pulse) . Since Omega FTB–1400 Flow Meters utilize a magnetic pick-up, the monitor is shipped configured for magnetic pick-up input . To change to a contact closure in-put, remove JP2 from the top two pins and jumper them to the bottom two pins . See Figure 4 .+10 - 30 VDC+1 - 5 VDCFigure 4: Wiring Diagram12Figure 5: Basic Programming Menu13REMOTE DISPLAY14151SWIVEL MOUNTFigure 6: MOUNTING OPTIONSFigure 7: Installation Drawing 16TROUBLESHOOTING GUIDEDEFAULT K-FACTOR VALUES17PART NUMBERINGFTB–1400–X D–LPMounting StyleM -Meter MountR -Remote MountS -Swivel MountREPLACEMENT PARTS18Where Do I Find Everything I Need for Process Measurement and Control?OMEGA…Of Course!Shop online at SMTEMPERATUREThermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point ReferencesRecorders, Controllers & Process Monitors Infrared PyrometersPRESSURE, STRAIN AND FORCETransducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & AccessoriesFLOW/LEVELRotameters, Gas Mass Flowmeters & Flow Computers Air Velocity IndicatorsTurbine/Paddlewheel Systems Totalizers & Batch ControllerspH/CONDUCTIVITYpH Electrodes, Testers & Accessories Benchtop/Laboratory MetersControllers, Calibrators, Simulators & Pumps Industrial pH & Conductivity EquipmentDATA ACQUISITIONData Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging System sRecorders, Printers & PlottersHEATERSHeating CableCartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory HeatersENVIRONMENTALMONITORING AND CONTROLMetering & Control Instrumentation Refractometers Pumps & TubingAir, Soil & Water MonitorsIndustrial Water & Wastewater TreatmentpH, Conductivity & Dissolved Oxygen InstrumentsM-5299/0613☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑☑。
外夹式超声波流量计简介外夹式超声波流量计(Clamp-On Ultrasonic Flowmeter)是一种采用高精度超声波传感技术实现的流量测量仪器。
它不需要切割管道,不需要停机,也不会污染管道介质。
这种流量计能够适用于多种流体介质,涵盖了水、油、化工及天然气等领域,适用于各种管道尺寸。
因此,外夹式超声波流量计在现代工业生产和交通等领域得到了广泛的应用。
工作原理外夹式超声波流量计能够通过超声波的传播时间差来得到流体的流速,从而计算出管道内的流量。
它采用了非侵入、高精度的测量方法,对被测液体无需任何影响。
外夹式超声波流量计需要将传感器分别安装在管道的两侧,通过超声波信号的反射和折射完成流量数据的测量。
传感器主要由发射器和接收器两个组成部分组成。
发射器发出超声波信号,信号在液体中传播并被接收器接收。
由于信号在流速和流体密度的影响下会发生变化,通过接收器收集到的反射信号,可以测量出管道中液体的流速。
外夹式超声波流量计还采用了多径测量技术,通过测量不同路径上的信号传播时间差,消除了信号中的不稳定性和异常数据,提高了测量精度。
应用场景外夹式超声波流量计的应用场景非常广泛,不仅适用于流量较大的管道,也适用于较小的管道。
同时,它是一种非侵入式的测量方法,不会对管道的运行产生任何影响。
因此,外夹式超声波流量计被广泛应用于下列领域:工业领域外夹式超声波流量计在工业生产过程中得到了广泛应用。
它可以用于水、油和化工生产等领域,也适用于能源、采矿和造纸等行业。
在工业领域,它常常用于监测生产流程中各个管道中流体的流速和流量,从而帮助企业掌握生产过程中的工艺参数,提高运营效率。
商业领域外夹式超声波流量计还可以用于商业领域,如超市、商场、酒店等。
它可以用于监测水和油等液体的流量,帮助商家掌握运营过程中各水、油管道中的流量情况,从而减少浪费、优化管理。
同时,它还可以用于商业领域中的节能环保和安全生产等方面,从而发挥着积极的作用。
便携式超声波流量计标准配置文章来源:华能自动化仪表有限公司特点:1、支持中英文菜单:HN系列便携式超声波流量计选用不同版本的流量计, 可支持中文或英文菜单, 方便快捷。
2、高精度测量:线性度优于0.5%,重复性精度优于0.2%,测量精度优于±1%。
3、内置数据记录器:可将提前设定的多达20余项的测量结果上传至计算机或联网通讯。
4、非接触式测量:HN系列便携式超声波流量计将带磁性的超声波流量计传感器吸附在管道外壁,即可完成流量测量。
5、测量范围大:选用不同型号的传感器, 可实现口径DN15 ~DN6000mm管道流量的测量。
6、充电电源:HN系列便携式超声波流量计内置大容量镍氢充电电池,可支持流量计连续工作20小时以上。
7、内置打印机:既可实现即时屏幕打印, 还可以定时打印提前设定的多达20余项的测量结果。
标准配置:主机、中型传感器、超声波专用电缆、电源适配器、高强度防护箱、拉紧器、数据线、说明书、超声波专用耦合剂。
便携式超声波流量计可选配的传感器:1、小型传感器TS-2(带磁性)、口径DN15~DN100mm、温度-40℃~110℃。
2、中型传感器TM-1(带磁性)、口径DN50~DN1000mm、温度-40℃~110℃。
3、中型传感器TL-1(带磁性)、口径DN300~DN6000mm、温度-40℃~110℃。
4、高温小型传感器HTS-1、口径DN15~DN100mm、温度-40℃~160℃。
5、高温中型传感器HTM-1、口径DN50~DN1000mm、温度-40℃~160℃。
便携式超声波流量计的性能参数:1、主机:2×20点阵式背光型液晶显示器,工作温度(-20~60℃)、打印机输出24列字符微型热敏打印机、4×4+2式轻触键盘、数据接RS-485,2、传感器标准TS-2型、适用于管径:DN15~DN100mm 流体温度≤110℃标准TM-1型、适用于管径:DN50~DN1000mm 流体温度≤110℃标准TL-1型、适用于管径:DN300~DN6000mm 流体温度≤110℃3、测量介质:水、海水、工业污水、酸碱液、各种油类等能传导声波的液体4、流速范围:0~±30m/s5、测量精度:优于±1%6、电源:镍氢电池可连续工作20小时以上或AC220V7、功耗:1.5W8、充电:采用智能充电方式,直接接入AV220V,充电后自动停止,显示绿灯9、重量:净重2.5Kg(主机)10、备注:配备一体式高强度防护箱,可以在野外恶劣环境中使用相关产品:手持式超声波流量计,固定一体功能型超声波流量计。
TDS-100系列超声波流量计概述目 录一 概述 (1)1.1引言 (1)1.2TDS-100的特点 (1)1.3工作原理 (1)1.4典型用途 (2)1.5装箱单(标准配置) (2)1.6可选备件 (2)1.7产品型号编码规则 (2)1.8外形图和接线图 (3)1.9性能指标 (3)二 开始安装测量 (5)2.1 开箱检查 (5)2.2供电电源 (5)2.3通电 (5)2.4键盘 (5)2.5怎样操作 (6)2.6窗口简介 (6)2.7快速输入管道参数和步骤 (7)2.8选择测量点 (7)2.9探头接线 (8)2.10安装探头 (8)2.11检查安装 (14)三 怎样使用 (16)3.1怎样判断流量计是否工作正常 (16)3.2怎样选择流量单位制....................................... . (16)3.3怎样选择瞬时流量单位.................................... . (16)3.4怎样选择累积流量单位.................................... . (16)3.5怎样选择累积器倍乘因子................................. . (16)3.6怎样打开或关闭流量器清零 (16)3.7怎样实现流量累积清零.................................... . (16)3.8怎样恢复出厂设置.................................... . (16)3.9怎样使用阻尼器稳定流量显示.................................... . (16)3.10怎样使用零点切除避免无效累积.................................... . (17)3.11设置零点提高测量精度.................................... . (17)3.12修改仪表系数(标尺因子)进行标定校正.................................... . (17)3.13密码保护.................................... . (17)3.14怎样使用打印机.................................... . (17)1TDS-100系列超声波流量计概述3.15怎样使用4-20mA电流环输出.................................... . (18)3.16怎样输出模拟电压信号.................................... (18)3.17怎样使用频率信号输出.................................... (18)3.18怎样输出累积脉冲.................................... (18)3.19怎样产生输出报警信号.................................... (18)3.20怎样使用OCT输出.................................... .. (19)3.21怎样使用继电器输出.................................... (19)3.22怎样修改日期时间.................................... (19)3.23怎样调整LCD显示器.................................... .. (19)3.24怎样使用RS232/RS485串行口.................................... .. (19)3.25怎样查看每日、每月、每年流量.................................... (19)3.26怎样连接压力信号和温度信号(模拟输入)............... (20)3.27怎样实现断电时间段内流量的自动补加............... (20)3.28怎样使用工作计时器............... (20)3.29怎样使用批量(定量)控制器............... . (20)3.30怎样对模拟输出进行校准............... (20)3.31查看电子序列号和其他细节............... (20)四 命令/显示窗口详解 (20)4.1显示窗口一览表............... (21)4.2显示窗口顺序介绍............... (22)五 问题处理 (39)表1硬件上电自检信息及原因对策......... .. (39)表2工作时错误代码原因及对策......... (39)其他常见问题问答......... .. (40)六 联网使用及通信协议 (42)6.1概述...... . (42)6.2流量计串行口定义...... . (42)6.3同上位机的RS232直接联接...... (42)6.4通信协议及其使用...... (42)七 质量保证及服务编修支持 (46)7.1质量保证 (46)7.2公司服务 (46)7.3产品升级 (46)7.4技术支持 (46)八 附录 (47)8.1常用液体声速和粘度 (47)8.2常用材料声速 (47)8.3水中声速表(1标准大气压下) (48)2TDS-100系列超声波流量计 概述第一章 概述§1.1 引言欢迎您选择使用性能更优异、功能更多、采用了全新技术制造的TDS-100系列超声波流量计。
丹尼尔气体超声波流量计参考、安装和操作手册(译文本)DANIEL(丹尼尔)测量与控制公司一家设在得克萨斯州休斯敦市的爱默森集团公司的过程管理公司本手册用于多通道高级气体超声波流量计– 3400型单通道普通气体超声波流量计– 3410型双通道普通气体超声波流量计– 3420型部件编号 3-9000-740修改版 E2002年9月中国石油西气东输管道公司翻译DANIEL测量与控制公司丹尼尔气体超声波流量计参考、安装和操作手册注意事项Emerson过程管理公司Daniel子公司将不对本手册中的技术错误或编辑错误或本手册内容的不足承担任何责任。
Daniel公司不会作出明示或暗示的质量担保,包括对与本手册有关的某一目的的商品性和适宜性作出暗示的质量担保;因此在任何情况下,Daniel公司都不会对任何特殊的或损害后果赔偿包括但不限于生产损失、利润损失等承担任何赔偿责任。
在本手册中使用到的产品名称仅仅是为了区分制造厂商或供货商,可能是这些公司的商标或注册商标。
本手册内容只用于参考的目的,尽管为保证信息的准确性已尽了全方位的努力,但对于下文中描述的产品和服务、以及它们的使用和适用性而言,这都不能解释为我们已作出明示或暗示的质量担保或保证。
我们保留随时修改或者完善这些产品设计或规格的权利。
DANIEL公司不对任何产品的选择、使用或者维护保养承担责任。
正确选择、使用和维护DANIEL产品的责任完全由购买者和终端用户自己承担。
DANIEL和DANIEL的图标为DANIEL工业公司的注册商标。
EMERSON图标是EMERSON电气公司的商标和服务标志。
本手册的版权归在美国得克萨斯州休斯敦市的Daniel公司。
Daniel公司保留所有权利。
在未收到美国得克萨斯州休斯敦市的Daniel公司的书面同意之前,不得以任何形式或采取任何手段- 包括图形、电子或者机械方法对本手册的任何部分进行复制或者拷贝。
质量保证1.有限质量保证:除了下文第二部分包含的限制内容以及在此另外明确规定的事宜以外,Daniel 测量和控制公司.(以下简称“Daniel公司”)保证:固件将执行Daniel 公司提供的程序指令;由Daniel公司制造的产品或提供的服务在正常使用和注意保养的情况下,在保用期到期前将不会出现材料或制造工艺缺陷。
一概述§1.1 引言欢迎您使用我公司研制生产的新一代TDS-100-1599855-1030-系列超声波流量计/超声波热量计/流量变送器/电池供电性超声波水表新一代TDS-100系列超声波流量计/超声波热量计/流量变送器/电池供电性超声波水表是在TDS-100第七版及第十一版超声波流量计的基础上,集11年专业生产制造超声波流量计的技术与经验,采用TI的MSP430FG4618低功耗单片机,最新开发的高性能、低价格、可靠性好、功能强大的全新系列产品。
新产品无论在测量精度、测量稳定性、通讯协议、使用方便性等方面都较原第7版超声波流量计有了很大的提高。
同时实现了生产过程中元器件参数无调整化,生产工艺更简单更可靠,产品一致性好,从而保证每一台出厂产品都达到最佳性能。
在软件操作菜单上继续延用第七版超声波流量计友好的用户界面,只是个别菜单的功能做了改动或增加,保证了公司的老用户非常简单容易的掌握。
新一代TDS-100系列超声波流量计/超声波热量计 /变送器/电池供电性超声波水表目前有四个不同型号的主板版本供用户选用,这四个版本分别称为第十三版、第十四版、第十五版和第十六版,简称为TDS13,TDS14,TDS15,TDS16。
本说明书适用于TDS-100M(模块型,TDS13主板)、TDS-100S(经济型,TDS14主板)、TDS-100F(固定分体式,TDS13主板、TDS15主板)、TDS-100Y(固定一体式,TDS16主板)TDS-100Z(变送型,TDS16主板)、TDS-100W(水表,TDS16主板)等型号的产品。
并对产品的安装、操作及通讯进行详细介绍。
公司出厂每台产品都使用唯一的8位电子序列号(ESN),用户使用产品前请核对产品出厂编号和电子序列号(第61号窗口)是否一致。
再按版本号和产品型号仔细阅读说明书中对应章节,具体编码规则如下:§1.2 工作原理当超声波束在液体中传播时,液体的流动将使传播时间产生微小变化,其传播时间的变化正比于液体的流速,零流量时,两个传感器发射和接收声波所需的时间完全相同(唯一可实际测量零流量的技术),液体流动时,逆流方向的声波传输时间大于顺流方向的声波传输时间。
ABB流量计产品介绍ABB(ASEA Brown Boveri)是一家全球领先的工业自动化和电力技术公司,致力于开发和制造各种先进的流量计产品,以满足不同行业的流量测量需求。
ABB流量计产品的特点包括高精度、可靠性、可定制化、易于安装和操作,广泛应用于石油和化工、造纸、食品和饮料、制药、电力等多个行业。
一、ABB流量计产品分类1. 电磁流量计(Electromagnetic Flowmeter):电磁流量计采用电磁感应原理,通过测量介质中电磁感应产生的电动势来计算流量。
ABB的电磁流量计具有可调节的精度、稳定性强、对介质的要求较低等优点。
同时,该产品还提供了多种型号和规格,以满足不同流量范围和管径的应用需求。
2. 涡街流量计(Vortex Flowmeter):涡街流量计采用涡街脉动信号与流体的速度成正比的原理测量流量。
ABB的涡街流量计具有高精度、广泛的应用范围、可靠性强等特点。
该产品适用于液体和气体的流量测量,并且可以在恶劣的工作环境下稳定工作。
3. 超声波流量计(Ultrasonic Flowmeter):超声波流量计是利用超声波在流体中传播速度的差异来进行流量测量的一种设备。
ABB的超声波流量计具有非接触式测量、无压力损失、测量准确度高等优点。
该产品可适用于各种粘度、温度和压力的流体测量。
4. 旋翼流量计(Rotameter):旋翼流量计是利用浮子在管道中的位置变化与流体流速成正比的原理来测量流量的一种设备。
ABB的旋翼流量计结构简单,操作方便,可适用于液体和气体的测量,并且适用于小流量和高温的特殊情况。
5. 直管式流量计(Orifice Flowmeter):直管式流量计是通过孔板、锥形孔板或环形孔板等装置,在管道内形成局部的压降,从而计算出流体流量的一种测量设备。
ABB的直管式流量计具有结构简单、精度高、使用方便等特点。
该产品适用于高温、高压和腐蚀性介质的流量测量。
二、ABB流量计产品特点1.高精度:ABB流量计产品采用先进的测量技术和精密的传感器,能够实现高精度的流量测量,并保证测量结果的可靠性和准确性。