RP40-11012DFR/P RP40-11024DFR/N-HC RP40-2405SFR/P RP40-2412SFR/N-HCRP40-4805SFR/P-HCFeaturesRegulated Converters• Wide 4:1 Input Voltage Range• 1.6kVDC Isolation for 24Vin and 48Vin, 3kVDC Isolation for 110Vin • Efficiency up to 92%• Six-Sided Continuous Shield• UL60950-1 AM2 Certified, EN50155 CertifiedPD-1REV.: 0/2016DC/DC Converter3 YE A Rw ar r a n t y3DescriptionThe RP40-FR series wide range input DC/DC converters have been especially designed for railway applications and are EN50155 certified. They are also pending to UL60950-1 and cUL 60950-1, this makes them ideal for all high input voltage telecom and industrial applications where approved safety standards are required.40 Watt2“ x 1“Single & Dual OutputRP40-FR Selection GuidePart Number Input Output Output Input (1) Efficiency (1)Max. Capacitive Voltage Range Voltage Current Current typ. Load (2) [VDC] [VDC] [mA] [mA] [%] [µF]RP40-243.3SFR (3,4)9-36 3.3 10000 1528 90 26600RP40-2405SFR (3,4) 9-36 5 8000 1832 91 20000RP40-2412SFR (3,4)9-36 12 3333 1811 92 3900RP40-2415SFR (3,4) 9-36 15 2666 1811 92 2600RP40-2424SFR (3,4)9-36 24 1666 1831 91 1300RP40-483.3SFR (3,4) 18-75 3.3 10000 764 90 26600RP40-4805SFR (3,4)18-75 5 8000 916 91 20000RP40-4812SFR (3,4) 18-75 12 3333 906 92 3900RP40-4815SFR (3,4)18-75 15 2666 906 92 2600RP40-4824SFR (3,4) 18-75 24 1666 915 91 1300 RP40-1103.3SFR (3,4) 43-160 3.3 10000 341 88 26600RP40-11005SFR (3,4) 43-160 5 8000 409 89 20000RP40-11012SFR (3,4)43-160 12 3333 402 90.5 3900RP40-11015SFR (3,4) 43-160 15 2666 400 91 2600RP40-11024SFR (3,4)43-160 24 1666 404 90 1300RP40-2412DFR (3,4) 9-36 ±12 ±1666 926 90 ±2600RP40-2415DFR (3,4)9-36 ±15 ±1333 926 90 ±1600RP40-2424DFR (3,4) 9-36 ±24 ±833 915 91 ±650RP40-4812DFR (3,4) 18-75 ±12 ±1666 463 90 ±2600RP40-4815DFR (3,4) 18-75 ±15 ±1333 370 90 ±1600RP40-4824DFR (3,4)18-75 ±24 ±833 286 91 ±650RP40-11012DFR (3,4) 43-160 ±12 ±1666 204 89 ±2600RP40-11015DFR (3,4) 43-160 ±15 ±1333 204 89 ±1600RP40-11024DFR (3,4)43-160 ±24 ±833 200 91 ±650Model NumberingOrdering ExamplesRP40-2405SFR/P = 24V Input, 5V Output, Positive Logic CTRL pin and Trim pin fitted RP40-2415SFR/N = 24V Input, 15V Output, Negative Logic CTRL pin and Trim pin fitted Input Voltage Output Voltage S ingle or D ualRP40-__ __ _FR/_ _Notes:Note1: Values at nominal input voltage and full load Note2: Test by minimum Vin and constant resistor load.EN50155 Certified UL60950-1 AM2 CertifiedE196683Notes:Note3: standard part is with suffix “P” for positive logic (1=ON, 0=OFF) and trim pin or add suffix “N” instead for negative logic (0=ON, 1=OFF) and trim pin Note4: add suffix “-HC” for premounted Heat-sink with clampsPackage (4)CTRL Logic (3)PD-2REV.: 0/2016DC/DC Conver terRP40-FRSeriesSpecifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)DC/DC Conver terSpecifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)REGULATIONSParameterConditionValueOutput Voltage Accuracy full load and nominal Vin±1%Voltage Adjustability Single3.3Vout, 5 Vout, 12Vout 15Vout, 24Vout ±10%-10% to +20%Line Voltage Regulation low line to high line at full load ±0.2%Load Voltage Regulation 0% to 100% loadSingle Dual±0.5%±1.0%Cross Regulationasymmetrical 25%<>100% load±5%Transient Response recovery time25% load step change 250µs typ.continued on next pageRP40-FRSeriesPD-3REV.: 0/PD-4REV.: 0/2016DC/DC Conver terSpecifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)RP40-FRSeriesDC/DC Conver terSpecifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)RP40-FRSeriesPD-5REV.: 0/ Trim up 12345678910%Vout =15.1515.315.4515.6015.7515.9016.0516.2016.3516.50Volts R U = 419.81199.91126.6089.9567.9653.3042.8334.9828.8723.98KOhms Trim up 11121314151617181920%Vout = 16.65016.80016.95017.10017.25017.40017.55017.70017.85018.000Volts R U = 19.9816.6513.8311.429.327.49 5.87 4.43 3.15 1.99KOhms Trim down 12345678910%Vout = 14.85014.70014.55014.40014.25014.00013.75013.50013.25013.000Volts R D =284.89128.6876.6150.5834.9624.5517.1111.537.193.72KOhmsTrim up 12345678910%Vout =24.24024.48024.72024.96025.20025.44025.68025.92026.16026.400Volts R U = 1275.2606.60383.73272.30205.44160.87129.03105.1586.5871.72KOhms Trim up 11121314151617181920%Vout = 26.64026.88027.12027.36027.60027.84028.08028.32028.56028.800Volts R U = 59.5649.4340.8633.5127.1521.5716.6612.298.38 4.86KOhms Trim down 12345678910%Vout = 23.76023.52023.28023.04022.80022.56022.32022.08021.84021.600Volts R D =838.15376.78222.98146.0999.9569.1947.2230.7417.937.68KOhmsRP40-xx15SFRRP40-xx24SFRPROTECTIONSParameterCondition ValueShort Circuit Protection (SCP)continuous, automatic recoveryOver Voltage Protection (OVP)Zener Diode Clamp 3.3Vout 5Vout12Vout15Vout 24Vout3.9VDC 6.2VDC 15VDC 20VDC 30VDCOver Load Protection (OLP)% Iout rated150% typ., Hiccup ModeOver Temperature Protection (OTP)115°C Isolation Voltage24Vin, 48VinI/P to O/PI/P to O/P to Case 1.6kVDC 1.6kVDC 110VinI/P to O/PI/P to O/P to Case3kVDC 1.6kVDC Isolation Resistance 500VDC1G Ω min.Isolation Capacitance1500pF max.Notes:Note6: This power module is not internally fused. An input line fuse must always be used.SAFETY AND CERTIFICATIONSCertificate Type (Safety)Report / File NumberStandard Information Technology Equipment, General Requirements for Safety E196683UL60950-1, 2nd Edition AM:2, 2014CSA C22.2 No. 60950-1-07Railway Applications - Electrical Equipment used on rolling stock15A100702E-CEN50155, 2007EMI ComplianceConditionStandard / CriterionIndustrial, scientific and medical equipment - Radio frequency disturbance characteristics - Limits and methods of measurement (8)with external filter EN50121-3-2, Class A EN55011, Class A or B ESD Electrostatic discharge immunity testRadiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity (9)Surge Immunity (9)Immunity to conducted disturbances, induced by radio-frequency fields Power Magnetic Field ImmunityAir ±8kV and Contact ±6kV20 V/m ±2kV ±2kV 10 Vr.m.s100A/m continuous; 1000A/m 1sEN61000-4-2, Criteria A EN61000-4-3, Criteria A EN61000-4-4, Criteria A EN61000-4-5, Criteria A EN61000-4-6, Criteria A EN61000-4-8, Criteria Acontinued on next pagePD-6REV.: 0/2016DC/DC Conver terSpecifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)RP40-FRSeriesDC/DC Conver terSpecifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)RP40-FRSeriesPD-7REV.: 0/2016PD-8REV.: 0/2016DC/DC Conver terSpecifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)RP40-FRSeriesDC/DC Conver terSpecifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)RP40-FR SeriesPD-9REV.: 0/2016 Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)DIMENSIONS and PHYSICAL CHARACTERISTICSParameter Type ValueMaterialCaseBasePottingCopper Alloy CuZn33FR4 PCBSilicone (UL94V-0)Packaging Dimension (LxWxH)without Heat-sinkwith Heat-sink50.8 x 25.4 x 10.2mm56.8 x 25.4 x 16.8mmPackaging Weightwithout Heat-sinkwith Heat-sink32g43g continued on next pagePD-10REV.: 0/PACKAGING INFORMATIONParameterTypeValuePackaging Quantity without Heat-sink with Heat-sink Tube Tray9pcs 20pcsStorage Temperature Range -55°C to +125°C Storage Humidity5% - 95% RHThe product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.25.4Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)PD-11REV.: 0/RP40-4815SFR/N RP40-4815SFR/N-RP40-483.3SFR/NHCRP40-11012DFR/P RP40-11024DFR/N-HC RP40-2405SFR/P RP40-2412SFR/N-HCRP40-4805SFR/P-HC。