NoticeCORRECTIONSERVICE FLASHPRODUCTION CHANGEADDED INFORMATIONREFERENCE NO. 700855-02FILE NO.Please add this notice to the TECHNICAL & SERVICE MANUAL listed below.For Parts or Service Assistance please contact your local Sanyo HVAC Contractor or DistributorUnited States: SCS, HVAC Solutions Web: Parts:********************.com Service:**********************.comCanada: Sanyo Canada Inc.Web: Parts/Service:**************.com4/10 Printed in JapanTECHNICAL & SERVICE MANUALOUTDOOR UNIT : CMH1972ACMH2472A CMH3172ADC INVERTER MULTI-SYSTEM AIR CONDITIONERDestination: North AmericaProduct Code No.1 852 356 131 852 356 091 852 356 10REFERENCE NO. 700855-02Capacity at 230V 19,100 BTU/h 23,200 BTU/h 30,600 BTU/hOutdoor Model No.CMH1972A CMH2472A CMH3172ACMH1972ACMH2472ACMH3172AFILE NO.••Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly,if not performed correctly.Important safety precautions are described for all items in both categories. Be sure to carefully follow all of them.• Symbol Indication:This symbol indicates items to which we need to pay attention.In this triangle, a definite precautionary item is described.:This symbol indicates the item to be prohibited.In or close to this circle, a prohibited item is described.This symbol indicates the items requiring special attention or instruction.In or close to this circle, a prohibited item is described.• After doing repair work, perform a test run to confirm that there are no abnormalities.At the same time, explain the precautions in use to the user.SAFETY PRECAUTIONSTable of Contents24678141718212447535962687172737478...........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................PageTABLE OF CONTENTS APPLICABLE INDOOR UNITS 1. OPERATING RANGE 2. SPECIFICATIONS2-1. Unit Specifications 2-2. Major Component Specifications 2-3. Other Component Specifications 3. DIMENSIONAL DATA 4. REFRIGERANT FLOW DIAGRAM4-1. Refrigerant Flow Diagram 5. PERFORMANCE DATA5-1. Temperature Charts 5-2. Cooling Capacity 5-3. Heating Capacity 6. ELECTRICAL DATA6-1. Electric Wiring Diagrams 7. FUNCTIONS7-1. Explanation of Functions 7-2. Protective Functions 8. TROUBLESHOOTING8-1. Precautions before Performing Inspection or Repair 8-2. Trouble Diagnosis by Error Monitop Lamps 8-3. Checking the Outdoor System 8-4. Trouble Diagnosis of Each Part 8-5. Trouble Diagnosis of Fan Motor7980818182848585A-1A-2............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................Page9. REFRIGERANT R410A:SPECIAL PRECAUTIONS WHEN SERVICING UNIT9-1. Characteristics of New Refrigerant R410A 9-2. Checklist before Servicing 9-3. Tools Specifically for R410A 9-4. Tubing Installation Procedures 9-5. In Case of Compressor Malfunction 9-6. In Case Refrigerant is Leaking 9-7. Charging Additional Refrigerant 9-8. Retro-Fitting Existing Systems APPENDIX A INSTALLATION INSTRUCTIONS APPENDIX B UNIT COMBINATION TABLESAPPLICABLE INDOOR UNITSCMH1972A CMH2472A CMH3172AMulti-Outdoor Unit Indoor Unit 3-Room 4-Room 4-RoomKMHS0772YES YES YESYES YES YESYES YES YESYES YES YESNO YES YESKMHS0972KMHS1272KMHS1872KMHS2472Wall Mounted TypeCMH1972A CMH2472A CMH3172AMulti-Outdoor Unit Indoor Unit3-Room 4-Room 4-RoomXMHS0972&PNR-XS1872YES YES YESYES YES YESYES YES YESXMHS1272&PNR-XS1872XHS1872&PNR-XS1872Semi-Concealed Type95 °F D.B. / 71 °F W.B.67 °F D.B. / 57 °F W.B.80 °F D.B. / 67 °F W.B. _ D.B. / _ W.B.1. OPERATING RANGEMaximum Minimum Maximum Minimum115 °F D.B. 14 °F D.B.75 °F D.B. / 65 °F W.B. 0 °F D.B.TemperatureIndoor Air Intake Temp.Outdoor Air Intake Temp.Cooling Heating2. SPECIFICATIONS2-1. Unit SpecificationsOutdoor Unit CMH1972A Indoor UnitKMHS0972 × 3Remarks:1.The values shown in performance section and electrical rating section above are based on the following unit combination.For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMHS0972 3units Outdoor Unit : CMH1972A 1unit2.Rating conditions are:Cooling :Indoor air temp.80°F D.B./ 67°F W.B Heating :Indoor air temp.70°F D.B.Outdoor air temp.95°F D.B./ 75°F W.B.Outdoor air temp.47°F D.B./ 43°F W.B.< 230V >DATA SUBJECT TO CHANGE WITHOUT NOTICE.CompressorRefrigerant / Amount charged at shipment Ibs (g)Refrigerant Control( 11,600 to 24,800 )( 3.40 to 7.30 )6.71,5007.71,73519,1005.6024,8007.30( 9,800 to 19,100 )( 2.90 to 5.60 )Shipping VolumeCooling Heating16,3002,800Net ShippingPackage DimensionsWeightHeight × Width × Depth Height × Width × DepthIbs (kg)Ibs (kg)cu.ft (m 3)(mm)inch (mm)3-Room Multi Outdoor UnitOutdoor Unit inch --187 to 253D i m e n s i o n s & W e i g h tRefrigerant Tubing ConnectionsUnit DimensionsE l e c t r i c a l R a t i n gSensible Capacity Latent CapacityW Power Input V A Available Voltage Range Running Amperes Operation Sound (High) Cool / Heat Narrow tube Wide tube Refrigerant inch (mm)Tube Diameter inch (mm)143.3152.112.71(65.0)(69.0)(0.36)33-27/32 × 40-5/8 × 16-1/4(860 × 1,032 × 413)(740 × 900 × 320)Outdoor Unit29-1/8 × 35-7/16 × 12-19/321/4 (6.35) × 33/8 (9.52) × 3ft (m)dB-A Max. allowable tubing length per unit Flare Type 82 (25)R410A / 6.17 (2,800)Electric Expansion ValveDC Twin Rotary (Inverter)Fan Speeds Auto (Hi, Me, Lo)ControlMicroprocessor F e a t u r e s HSPFCompressor Locked Rotor Amperes BTU/Wh50 / 52BTU/h P e r f o r m a n c e-8.8%Power Factor 9898A 14.5TypeBTU/h kW Total CapacityBTU/h SEER BTU/Wh 16.4-3Number of Connectable Indoor Units 3Number of Operatable Indoor Units 230V Single-Phase 60HzVoltage Rating 1,707 (2,900)1,707 (2,900)Air Circulation (High)ft 3/min (m 3/h)COP W/W - 4.2EER BTU/h/W12.7-Fuse or Circuit Breaker CapacityA20Outdoor Unit CMH1972A Indoor UnitKMHS0972 × 3Remarks:1.The values shown in performance section and electrical rating section above are based on the following unit combination.For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMHS0972 3units Outdoor Unit : CMH1972A 1unit2.Rating conditions are:Cooling :Indoor air temp.80°F D.B./ 67°F W.B Heating :Indoor air temp.70°F D.B.Outdoor air temp.95°F D.B./ 75°F W.B.Outdoor air temp.47°F D.B./ 43°F W.B.< 208V >DATA SUBJECT TO CHANGE WITHOUT NOTICE.CompressorRefrigerant / Amount charged at shipment Ibs (g)Refrigerant Control( 11,600 to 24,800 )( 3.40 to 7.30 )7.41,5008.51,73519,1005.6024,8007.30( 9,800 to 19,100 )( 2.90 to 5.60 )Shipping VolumeCooling Heating16,3002,800Net ShippingPackage DimensionsWeightHeight × Width × Depth Height × Width × DepthIbs (kg)Ibs (kg)cu.ft (m 3)(mm)inch (mm)3-Room Multi Outdoor UnitOutdoor Unit inch --187 to 253D i m e n s i o n s & W e i g h tRefrigerant Tubing ConnectionsUnit DimensionsE l e c t r i c a l R a t i n gSensible Capacity Latent CapacityW Power Input V A Available Voltage Range Running Amperes Operation Sound (High) Cool / Heat Narrow tube Wide tube Refrigerant inch (mm)Tube Diameter inch (mm)143.3152.112.71(65.0)(69.0)(0.36)33-27/32 × 40-5/8 × 16-1/4(860 × 1,032 × 413)(740 × 900 × 320)Outdoor Unit29-1/8 × 35-7/16 × 12-19/321/4 (6.35) × 33/8 (9.52) × 3ft (m)dB-A Max. allowable tubing length per unit Flare Type 82 (25)R410A / 6.17 (2,800)Electric Expansion ValveDC Twin Rotary (Inverter)Fan Speeds Auto (Hi, Me, Lo)ControlMicroprocessor F e a t u r e s HSPFCompressor Locked Rotor Amperes BTU/Wh50 / 52BTU/h P e r f o r m a n c e-8.8%Power Factor 9898A 14.5TypeBTU/h kW Total CapacityBTU/h SEER BTU/Wh 16.4-3Number of Connectable Indoor Units 3Number of Operatable Indoor Units 208V Single-Phase 60HzVoltage Rating 1,707 (2,900)1,707 (2,900)Air Circulation (High)ft 3/min (m 3/h)COP W/W - 4.2EER BTU/h/W12.7-Fuse or Circuit Breaker CapacityA20Outdoor Unit CMH2472A Indoor UnitKMHS0972 × 3Remarks:1.The values shown in performance section and electrical rating section above are based on the following unit combination.For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMHS0972 3units Outdoor Unit : CMH2472A 1unit2.Rating conditions are:Cooling :Indoor air temp.80°F D.B./ 67°F W.B Heating :Indoor air temp.70°F D.B.Outdoor air temp.95°F D.B./ 75°F W.B.Outdoor air temp.47°F D.B./ 43°F W.B.< 230V >DATA SUBJECT TO CHANGE WITHOUT NOTICE.CompressorRefrigerant / Amount charged at shipment Ibs (g)Refrigerant Control( 11,600 to 29,200 )( 3.40 to 8.60 )9.02,04010.12,27023,2006.8029,2008.60( 9,800 to 23,200 )( 2.90 to 6.80 )Shipping VolumeCooling Heating19,6003,600Net ShippingPackage DimensionsWeightHeight × Width × Depth Height × Width × DepthIbs (kg)Ibs (kg)cu.ft (m 3)(mm)inch (mm)4-Room Multi Outdoor UnitOutdoor Unit inch --187 to 253D i m e n s i o n s & W e i g h tRefrigerant Tubing ConnectionsUnit DimensionsE l e c t r i c a l R a t i n gSensible Capacity Latent CapacityW Power Input V A Available Voltage Range Running Amperes Operation Sound (High) Cool / Heat Narrow tube Wide tube Refrigerant inch (mm)Tube Diameter inch (mm)143.3152.112.71(65.0)(69.0)(0.36)33-27/32 × 40-5/8 × 16-1/4(860 × 1,032 × 413)(740 × 900 × 320)Outdoor Unit29-1/8 × 35-7/16 × 12-19/321/4 (6.35) × 43/8 (9.52) × 3 + 1/2 (12.7) × 1ft (m)dB-A Max. allowable tubing length per unit Flare Type 82 (25)R410A / 6.17 (2,800)Electric Expansion ValveDC Twin Rotary (Inverter)Fan Speeds Auto (Hi, Me, Lo)ControlMicroprocessor F e a t u r e s HSPFCompressor Locked Rotor Amperes BTU/Wh50 / 52BTU/h P e r f o r m a n c e-8.4%Power Factor 9898A 14.5TypeBTU/h kW Total CapacityBTU/h SEER BTU/Wh 16.5-4Number of Connectable Indoor Units 4Number of Operatable Indoor Units 230V Single-Phase 60HzVoltage Rating 1,707 (2,900)1,707 (2,900)Air Circulation (High)ft 3/min (m 3/h)COP W/W - 3.8EER BTU/h/W11.4-Fuse or Circuit Breaker CapacityA20Outdoor Unit CMH2472A Indoor UnitKMHS0972 × 3Remarks:1.The values shown in performance section and electrical rating section above are based on the following unit combination.For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMHS0972 3units Outdoor Unit : CMH2472A 1unit2.Rating conditions are:Cooling :Indoor air temp.80°F D.B./ 67°F W.B Heating :Indoor air temp.70°F D.B.Outdoor air temp.95°F D.B./ 75°F W.B.Outdoor air temp.47°F D.B./ 43°F W.B.< 208V >DATA SUBJECT TO CHANGE WITHOUT NOTICE.CompressorRefrigerant / Amount charged at shipment Ibs (g)Refrigerant Control( 11,600 to 29,200 )( 2.90 to 8.60 )10.02,04011.12,27023,2006.8029,2008.60( 9,800 to 23,200 )( 2.90 to 6.80 )Shipping VolumeCooling Heating19,6003,600Net ShippingPackage DimensionsWeightHeight × Width × Depth Height × Width × DepthIbs (kg)Ibs (kg)cu.ft (m 3)(mm)inch (mm)4-Room Multi Outdoor UnitOutdoor Unit inch --187 to 253D i m e n s i o n s & W e i g h tRefrigerant Tubing ConnectionsUnit DimensionsE l e c t r i c a l R a t i n gSensible Capacity Latent CapacityW Power Input V A Available Voltage Range Running Amperes Operation Sound (High) Cool / Heat Narrow tube Wide tube Refrigerant inch (mm)Tube Diameter inch (mm)143.3152.112.71(65.0)(69.0)(0.36)33-27/32 × 40-5/8 × 16-1/4(860 × 1,032 × 413)(740 × 900 × 320)Outdoor Unit29-1/8 × 35-7/16 × 12-19/321/4 (6.35) × 43/8 (9.52) × 3 + 1/2 (12.7) × 1ft (m)dB-A Max. allowable tubing length per unit Flare Type 82 (25)R410A / 6.17 (2,800)Electric Expansion ValveDC Twin Rotary (Inverter)Fan Speeds Auto (Hi, Me, Lo)ControlMicroprocessor F e a t u r e s HSPFCompressor Locked Rotor Amperes BTU/Wh50 / 52BTU/h P e r f o r m a n c e-8.4%Power Factor 9898A 14.5TypeBTU/h kW Total CapacityBTU/h SEER BTU/Wh 16.5-4Number of Connectable Indoor Units 4Number of Operatable Indoor Units 208V Single-Phase 60HzVoltage Rating 1,707 (2,900)1,707 (2,900)Air Circulation (High)ft 3/min (m 3/h)COP W/W - 3.8EER BTU/h/W11.4-Fuse or Circuit Breaker CapacityA20Outdoor Unit CMH3172A Indoor UnitKMHS0972 × 4Remarks:1.The values shown in performance section and electrical rating section above are based on the following unit combination.For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMHS0972 4units Outdoor Unit : CMH3172A 1unit2.Rating conditions are:Cooling :Indoor air temp.80°F D.B./ 67°F W.B Heating :Indoor air temp.70°F D.B.Outdoor air temp.95°F D.B./ 75°F W.B.Outdoor air temp.47°F D.B./ 43°F W.B.< 230V >DATA SUBJECT TO CHANGE WITHOUT NOTICE.CompressorRefrigerant / Amount charged at shipment Ibs (g)Refrigerant Control( 11,600 to 32,000 )( 3.40 to 9.40 )12.32,80010.32,35030,6009.0032,0009.40( 9,800 to 30,600 )( 2.90 to 9.00 )Shipping VolumeCooling Heating25,8004,800Net ShippingPackage DimensionsWeightHeight × Width × Depth Height × Width × DepthIbs (kg)Ibs (kg)cu.ft (m 3)(mm)inch (mm)4-Room Multi Outdoor UnitOutdoor Unit inch --187 to 253D i m e n s i o n s & W e i g h tRefrigerant Tubing ConnectionsUnit DimensionsE l e c t r i c a l R a t i n gSensible Capacity Latent CapacityW Power Input V A Available Voltage Range Running Amperes Operation Sound (High) Cool / Heat Narrow tube Wide tube Refrigerant inch (mm)Tube Diameter inch (mm)180.8189.615.18(82.0)(86.0)(0.43)39-3/4 × 40-5/8 × 16-1/4(1,010 × 1,032 × 413)(890 × 900 × 320)Outdoor Unit35-1/32 × 35-7/16 × 12-19/321/4 (6.35) × 43/8 (9.52) × 2 + 1/2 (12.7) × 2ft (m)dB-A Max. allowable tubing length per unit Flare Type 100 (30.5)R410A / 8.38 (3,800)Electric Expansion ValveDC Twin Rotary (Inverter)Fan Speeds Auto (Hi, Me, Lo)ControlMicroprocessor F e a t u r e s HSPFCompressor Locked Rotor Amperes BTU/Wh53 / 52BTU/h P e r f o r m a n c e-9.3%Power Factor 9999A 17.0TypeBTU/h kW Total CapacityBTU/h SEER BTU/Wh 17.2-4Number of Connectable Indoor Units 4Number of Operatable Indoor Units 230V Single-Phase 60HzVoltage Rating 1,942 (3,300)1,807 (3,070)Air Circulation (High)ft 3/min (m 3/h)COP W/W - 4.0EER BTU/h/W10.9-Fuse or Circuit Breaker CapacityA20Outdoor Unit CMH3172A Indoor UnitKMHS0972 × 4Remarks:1.The values shown in performance section and electrical rating section above are based on the following unit combination.For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : KMHS0972 4units Outdoor Unit : CMH3172A 1unit2.Rating conditions are:Cooling :Indoor air temp.80°F D.B./ 67°F W.B Heating :Indoor air temp.70°F D.B.Outdoor air temp.95°F D.B./ 75°F W.B.Outdoor air temp.47°F D.B./ 43°F W.B.< 208V >DATA SUBJECT TO CHANGE WITHOUT NOTICE.CompressorRefrigerant / Amount charged at shipment Ibs (g)Refrigerant Control( 11,600 to 32,000 )( 3.40 to 9.40 )13.62,80011.42,35028,6008.4032,0009.40( 9,800 to 28,600 )( 2.90 to 8.40 )Shipping VolumeCooling Heating24,2004,400Net ShippingPackage DimensionsWeightHeight × Width × Depth Height × Width × DepthIbs (kg)Ibs (kg)cu.ft (m 3)(mm)inch (mm)4-Room Multi Outdoor UnitOutdoor Unit inch --187 to 253D i m e n s i o n s & W e i g h tRefrigerant Tubing ConnectionsUnit DimensionsE l e c t r i c a l R a t i n gSensible Capacity Latent CapacityW Power Input V A Available Voltage Range Running Amperes Operation Sound (High) Cool / Heat Narrow tube Wide tube Refrigerant inch (mm)Tube Diameter inch (mm)180.8189.615.18(82.0)(86.0)(0.43)39-3/4 × 40-5/8 × 16-1/4(1,010 × 1,032 × 413)(890 × 900 × 320)Outdoor Unit35-1/32 × 35-7/16 × 12-19/321/4 (6.35) × 43/8 (9.52) × 2 + 1/2 (12.7) × 2ft (m)dB-A Max. allowable tubing length per unit Flare Type 100 (30.5)R410A / 8.38 (3,800)Electric Expansion ValveDC Twin Rotary (Inverter)Fan Speeds Auto (Hi, Me, Lo)ControlMicroprocessor F e a t u r e s HSPFCompressor Locked Rotor Amperes BTU/Wh53 / 52BTU/h P e r f o r m a n c e-9.3%Power Factor 9999A 17.0TypeBTU/h kW Total CapacityBTU/h SEER BTU/Wh 17.2-4Number of Connectable Indoor Units 4Number of Operatable Indoor Units 208V Single-Phase 60HzVoltage Rating 1,942 (3,300)1,807 (3,070)Air Circulation (High)ft 3/min (m 3/h)COP W/W - 4.0EER BTU/h/W10.9-Fuse or Circuit Breaker CapacityA20Outdoor UnitCMH1972A2-2-1. Outdoor UnitControl PCBControl Circuit Fuse ControlsPart No.Microprocessor 250V 25ACB-CMH1972A Pints (cc) -Micro F VACExternal FinishAcrylic baked-on enamel finishFV50S ... 1.91 (900)--Internal ControllerYes Yes Aluminum Plate Fin / Copper Tube218.1 Face Area ft 2 (m 2)6.40 (0.595) Coil RowsFins per inch Heat Exchanger CoilSIC-71FW-D490-1 (1)Compressor Oil ... Amount 890750 / 750OhmDC MotorTypeCompressor Model / Nominal Output CompressorCoil Resistance (Ambient Temp. 68 °F (20 °C))OhmDC Twin Rotary (Hermetic)5KD240XAB21 / 1,700W U - V :V - W :W - U :0.7200.7080.726CT (Peak current cut-off control)Compressor Discharge Temp. ControlOperation cut-off control in abnormal ambient Temp.Safety DeviceMicro F VACRun Capacitor Crankcase HeaterYes Yes Yes Overload RelayCS-7L-2515ModelOperation Temp.Open : 239 °F (115 °C), Close : 212 °F (100 °C)--230V 30W1 ... D18-1/8 (D460)FanPropellerQ'ty ... Dia.inch (mm)TypeTypeOver-Current Protection Over-Heat Protection(Ambient Temp. 68 °F (20 °C)) Fan MotorNominal Output Coil ResistanceSafety DeviceRough Measure RPM (Cool / Heat)Run Capacitor TypeModel ... Q'ty No. of PolesW 2-2. Major Component SpecificationsOutdoor Unit CMH2472AControl PCBControl Circuit Fuse ControlsPart No.Microprocessor 250V 25ACB-CMH2472A Pints (cc) -Micro F VACExternal FinishAcrylic baked-on enamel finishFV50S ... 1.91 (900)--Internal ControllerYes Yes Aluminum Plate Fin / Copper Tube218.1 Face Area ft 2 (m 2)6.40 (0.595) Coil RowsFins per inch Heat Exchanger CoilSIC-71FW-D490-1 (1)Compressor Oil ... Amount 890750 / 750OhmDC MotorTypeCompressor Model / Nominal Output CompressorCoil Resistance (Ambient Temp. 68 °F (20 °C))OhmDC Twin Rotary (Hermetic)5KD240XAB21 / 1,700W U - V :V - W :W - U :0.7200.7080.726CT (Peak current cut-off control)Compressor Discharge Temp. ControlOperation cut-off control in abnormal ambient Temp.Safety DeviceMicro F VACRun Capacitor Crankcase HeaterYes Yes Yes Overload RelayCS-7L-2515ModelOperation Temp.Open : 239 °F (115 °C), Close : 212 °F (100 °C)--230V 30W1 ... D18-1/8 (D460)FanPropellerQ'ty ... Dia.inch (mm)TypeTypeOver-Current Protection Over-Heat Protection(Ambient Temp. 68 °F (20 °C)) Fan MotorNominal Output Coil ResistanceSafety DeviceRough Measure RPM (Cool / Heat)Run Capacitor TypeModel ... Q'ty No. of PolesWOutdoor Unit CMH3172AControl PCBControl Circuit Fuse ControlsPart No.Microprocessor 250V 25ACB-CMH3172A Pints (cc) -Micro F VACExternal FinishAcrylic baked-on enamel finishFV50S ... 2.55 (1,200)--Internal ControllerYes Yes Aluminum Plate Fin / Copper Tube218.1 Face Area ft 2 (m 2)7.75 (0.72) Coil RowsFins per inch Heat Exchanger CoilSIC-71FW-D490-1 (1)Compressor Oil ... Amount 890800 / 750OhmDC MotorTypeCompressor Model / Nominal Output CompressorCoil Resistance (Ambient Temp. 68 °F (20 °C))OhmDC Twin Rotary (Hermetic)5JD420XAB22 / 3,000W U - V :V - W :W - U :0.4350.4410.452CT (Peak current cut-off control)Compressor Discharge Temp. ControlOperation cut-off control in abnormal ambient Temp.Safety DeviceMicro F VACRun Capacitor Crankcase HeaterYes Yes Yes Overload RelayCS-7L-2515ModelOperation Temp.Open : 239 °F (115 °C), Close : 212 °F (100 °C)--230V 30W1 ... D18-1/8 (D460)FanPropellerQ'ty ... Dia.inch (mm)TypeTypeOver-Current Protection Over-Heat Protection(Ambient Temp. 68 °F (20 °C)) Fan MotorNominal Output Coil ResistanceSafety DeviceRough Measure RPM (Cool / Heat)Run Capacitor TypeModel ... Q'ty No. of PolesWTemperature F ( C)403530252015105(-20)(-15)(-10)(-5)(0)(5)(10)(15)(20)-4514233241505968Resistance(kohm)3250688610412214015817619440608010012014016018020020Resistance(kohm)2-3. Other Component SpecificationsCMH1972A CMH2472A CMH3172A Sensor NameCompressor temp sensor TKS293BModel No.of sensor11Quantity of Sensor1 Outdoor air temp sensorOutdoor heat exchanger sensorAW / AN sensorBW / BN sensorCW / CN sensorDW / DN sensorTKS295BTKS292BTKS292BTKS292BTKS292BTKS292BModel No.of sensorSensor Name111 / 11 / 11 / 1Quantity of Sensor111 / 11 / 11 / 11 / 1111 / 11 / 11 / 11 / 1CMH1972A CMH2472A CMH3172A3. DIMENSIONAL DATAOutdoor Unit CMH1972AUnit: inch(mm)(852-0-0010-11200-0)Unit: inch(mm)(852-0-0010-20400-0)Unit: inch(mm)(852-0-0010-20300-0)Cooling cycle Heating cycleIndoor unitOutdoor unit4. REFRIGERANT FLOW DIAGRAM4-1. Refrigerant Flow DiagramOutdoor Unit CMH1972AInsulation of Refrigerant TubingBecause capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping ofcondensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min.5/16"(8 mm).After a tube has been insulated,never try to bend it into a narrow curve because it can cause the tube to break or crack.Thickness:Outdoor Unit CMH2472AInsulation of Refrigerant TubingBecause capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping ofcondensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min.5/16"(8 mm).After a tube has been insulated,never try to bend it into a narrowcurve because it can cause the tubeto break or crack.Thickness:Cooling cycleHeating cycleIndoor unit Outdoor unitCooling cycleHeating cycleIndoor unitOutdoor unitOutdoor Unit CMH3172AInsulation of Refrigerant TubingBecause capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping ofcondensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min.5/16"(8 mm).After a tube has been insulated,never try to bend it into a narrow curve because it can cause the tube to break or crack.Thickness:。
HIROSS恒温恒湿机房精密空调操作手册HIMOD系列北京****科技有限公司技术部2009年01月01日目录第一章 HIMOD系列海洛斯空调概述............................................1.1型号多..................................................................1.2控制技术先进............................................................1.3制冷系统................................................................1.4送风系统................................................................1.5加湿系统................................................................1.6加热系统................................................................1.7其它.................................................................... 第二章 HIMOD系列海洛斯空调型号含义........................................ 第三章有关空调的一些资料.................................................3.1气流组织方式............................................................3.2盖板纽开启方式..........................................................3.3空调重量..............................................................3.4机组尺寸及维护空间...................................................... 第四章制冷循环管路示意图.................................................4.1风冷却(A型)...........................................................4.2水冷却(W型)...........................................................4.3双冷源(D型)...........................................................4.4单系统(C型)...........................................................4.5双系统(C型).......................................................... 第五章调速风机调速接线示意图............................................. 第六章 MICROFACE概述......................................................6.1概述....................................................................6.2Microface面板简介.......................................................6.3LCD液晶显示屏介绍....................................................... 第七章 MICROFACE面板的操作................................................ 第八章控制器的使用.......................................................8.1控制器(HIROMATIC)概述.................................................8.2控制器的操作............................................................8.3菜单结构................................................................ 第九章日常维护及特殊维护.................................................9.1日常维护................................................................9.2特殊维护................................................................ 第十章常见报警及处理........................................................10.1低压报警...............................................................10.2高压报警...............................................................10.3加湿报警...............................................................10.4失风报警...............................................................10.5电加热过热报警.........................................................10.6显示器发黑.............................................................10.7空调不制冷............................................................. 附录 1:参数列表.......................................................... 附录2:报警内容列表....................................................... 附录3:各菜单项含义.......................................................第一章 HIMOD系列海洛斯空调概述HIMOD系列海洛斯空调(HIMOD空调)是当今世界上最先进的机房专用恒温恒湿机房专用精密空调。
海瑞弗精密空调HAUR0301技术规格书一、产品基本性能:1.海瑞弗恒温恒湿精密空调的电气性能海瑞弗空调机组的电气性能符合IEC标准海瑞弗空调机组的输入电压允许波动范围:380V ±20% 频率:50HZ ± 2HZ 2.海瑞弗空调机组的适应环境温度:室内 0℃~ +50℃室外 -50℃~ +50℃湿度:≤95%RH3.海瑞弗空调机组的温湿度控制性能1) 设备能按客户要求自动调节室内温、湿度,具有制冷、加热、加湿、除湿等功能。
2) 海瑞弗空调机组的温度调节范围:回风:+17℃~ +28℃送风:+10℃~ +21℃温度调节精度:±1.0℃温度变化率< 5℃/小时湿度调节范围:20% ~ 75%RH湿度调节精度:±3.0%RH温、湿度波动超限能发出声光报警信号4、海瑞弗空调机组的性能1) 冷量:24℃、50%RH时:总冷量:≥31.5 KW/台风量:≥9000立方米/小时/台2) 海瑞弗恒温恒湿精密空调能解决机房的高显热量负荷:显热比≥0.993) 海瑞弗恒温恒湿精密空调具有高效节能性,压缩机具有较高的能效比(总冷量与压缩机输入功率比值):≥ 3.714)海瑞弗恒温恒湿精密空调的风机采用直联驱动的直联风机,避免了采用皮带式传动风机造成的维护费用增加,现场调整困难以及造成二次粉尘污染的问题。
5)海瑞弗恒温恒湿精密空调的机外余压可以由控制器任意调整,便于空调机组根据机房内发热设备变化可以任意调整。
6)当恒温恒湿精密空调的空气过滤器出现脏堵时,为避免气流减少,海瑞弗机组能够自动提高风机转速,提高风压。
7)海瑞弗恒温恒湿精密空调系统具有高可靠性;8)海瑞弗恒温恒湿精密空调系统采用环保机型的机组,可以使用环保型R407C 替代工质制冷剂且制冷效率不低于原制冷剂R22的10%。
9) 海瑞弗恒温恒湿精密空调的加湿性能:具备高性能稳定可靠的加湿功能。
采用先进的电极式加湿,能直接使用未经二次软化的自来水水源,能对水垢或污物进行方便的清洗,可重复使用或长期使用。
行间空调电气控制说明书版本管理目录1系统配置 (4)2系统参数 (4)3.电气配置 (4)4.输入/输出定义 (4)4.1模拟量输入 (4)4.2数字量输入 (5)4.3数字量输出 (6)4.4模拟量输出 (6)5.控制功能 (7)5.1.运行模式 (7)5.2室内风机控制 (7)5.3室外风机控制 (7)5.4提升泵 (7)5.5压缩机控制 (8)5.5保护功能 (8)6.触摸屏的设定 (10)6.1主菜单 (10)6.2报警记录 (10)6.3菜单 (11)1系统配置2系统参数3.电气配置4.输入/输出定义4.1模拟量输入4.2数字量输入4.3数字量输出4.4模拟量输出5.控制功能5.1.运行模式制冷:当温度>设定温度+制冷温差的百分比开始制冷,当温度下降到设定温度-制冷温差的百分比制冷终止,控制的方式是比例控制。
加热:当温度<设定温度-制热温差百分比开始制热,当温度>设定温度+制热温差百分比停止制热,比例控制加热时,根据温度控制电加热,可选二进制式控制和分步控制。
加湿:室内湿度<湿度设定点-湿度偏差,加湿输出,打开加湿接触器;室内湿度>加湿设定点+湿度偏差,关闭加湿功能,加湿接触器关闭,加湿时根据湿度比例控制加湿器,通过MODBUS给CPY信号。
除湿:制冷除湿,当环境湿度>湿度设定点+湿度变差偏差值开压缩机,同时供液电磁阀开;默认送风湿度控制,可选回风湿度控制。
除湿时,压缩机根据预设频率运行,默认80%;送风机的风速是60%(可调),当然如果除湿温度过低,电加热会打开,进行温度的补偿,达到控制湿度的目的。
5.2.室内风机控制根据冷通道远端温度比例调节风速,如NTC都存在且正常,制冷时以温度高的NTC来控制,制热时以温度低的NTC来控制,只有这2个NTC温差超过1℃时,才需要切换;如果只有1个NTC正常,以这个NTC来控制。
除湿时根据预设固定风速运行,默认60%。
设最高/最低风速限制。
Side Discharge AC ModelsFor coastal applications where units are installed within one(1)mile of salt water,epoxy coated models are recommended.These models have an8week lead time after order.E p o x y C o a t e d M o d e l4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A 4TTL6018A1COTA4TTL6024A1COTA4TTL6030A1COTA4TTL6036A1COTA4TTL6042A1COTA4TTL6048A1COTA4TTL6060A1COTAN o t e:“Graphics in this document are for representationonly.Actual model may differ in appearance.”Product DataMay202022-1931-1H-E NOutline DrawingDWG. D159818_Rev DSound Power LevelNote:Rated in accordance with AHRI Standard270*For Reference OnlyNote:Rated in accordance with AHRI Standard275Product Specifications(a)Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard210/240.(b)Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses.(c)Standard line lengths—150’,Standard lift—50’Suction and Liquid line.For Greater lengths and lifts refer to refrigerantpiping software Pub#32–3312–0*(*denotes latest revision)..(d)Available from Trane Parts(e)25,30,35and50foot linesets available.For a complete listing of lineset options available from equipment or supply stores,refer to the Trane Residential and Light Commercial Product Handbook.(a)Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard210/240.(b)Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses.(c)Standard line lengths—150’,Standard lift—50’Suction and Liquid line.For Greater lengths and lifts refer to refrigerantpiping software Pub#32–3312–0*(*denotes latest revision)..(d)Available from Trane Parts(e)25,30,35and50foot linesets available.For a complete listing of lineset options available from equipment or supply stores,refer to the Trane Residential and Light Commercial Product Handbook.Accessory Description and UsageE v a p o r a t i o n D e f r o s t C o n t r o l—SPST Temperature actuated switch that cycles the condenseroff as indoor coil reaches freeze-up ed for low ambient cooling to30°F with TXV.R u b b e r I s o l a t o r s—Six(6)large rubber donuts to isolate condensing unit from transmittingenergy into mounting frame or e on any application where sound transmission needs tobe minimized.H a r d S t a r t K i t—Start capacitor and relay to assist compressor motor e in areas withmarginal power supply,on long linesets,low ambient conditions,etc.A H R I S t a n d a r d C a p a c i t y R a t i n g C o n d i t i o n sAHRI Standard210/240Rating Conditions1.Cooling80°F DB,67°F WB air entering indoor coil,95°F DB air entering outdoor coil.A H R I S t a n d a r d270R a t i n g C o n d i t i o n s—(Noise rating numbers are determined with the unit incooling operations.)Standard Noise Rating number is at95°F outdoor air.Model NomenclatureOutdoor Units3 = 134 = 145 = 15WiringFigure1.Schematic:1.5—4Ton ModelsNOTES:1. IF ODT-B IS NOT USED, ADD JUMPER BETWEENW2 & W3 AT AIR HANDLER. IF USED, ODT-B MUSTBE MOUNTED REMOTE OF CONTROL BOX IN ANAPPROVED WEATHER PROOF ENCLOSURE.2. IF ODT-A IS NOT USED, ADD JUMPER BETWEENW1& W2 AT AIR HANDLER.3. LOW VOLTAGE (24V) FIELD SIRING MUST BE 18 AWG MIN.4. USE COPPER CONDUCTORS ONLY!Dwg. D159847P01Figure 2.Schematic:1.5—4TonModelsFigure 3.Schematic:5TonModelFigure 4.Schematic:5TonModelMechanical Specification OptionsG e n e r a lThe outdoor condensing units are factory charged with the system charge required for theoutdoor condensing unit,ten(10)feet of tested connecting line,and the smallest rated indoorevaporative coil match.This unit is designed to operate at outdoor ambient temperatures as highas115°F.Cooling capacities are matched with a wide selection of air handlers and furnace coilsthat are AHRI certified.The unit is certified to UL1995.Exterior is designed for outdoorapplication.C a s i n gUnit casing is constructed of heavy gauge,galvanized steel and painted with a weather-resistantpowder paint finish.The corner panels are prepainted.All panels are subjected to our1,000hoursalt spray test.R e f r i g e r a n t C o n t r o l sRefrigeration system controls include condenser fan,compressor contactor and low and highpressure switches.A factory supplied,field installed liquid line drier is standard.C o m p r e s s o rThe compressor features internal over temperature and pressure protection.Other featuresinclude:Centrifugal oil pump and low vibration and noise.C o n d e n s e r C o i lThe outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protectedon all four sides by louvered panels.L o w A m b i e n t C o o l i n gAs manufactured,this system has a cooling capacity to55°F.The addition of an evaporatordefrost control permits operation to40°F.The addition of an evaporator defrost control with TXVpermits low ambient cooling to30°F.The addition of the BAYLOAM107A low ambient kit permits ambient cooling to20°F.T h e r m o s t a t s—Cooling only and heat/cooling(manual and automatic change over).Sub-base tomatch thermostat and locking thermostat cover.22-1931-1H-EN11Trane-by Trane Technologies(NYSE:TT),a global innovator-creates comfortable,energy efficient indoor environments for commercial and residential applications.For more information,please visit or .The AHRI Certified mark indicates Trane U.S.Inc.participation in the AHRI Certification program.For verification of individual certified products,go to ahridirectory. org.Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices.22-1931-1H-EN13May2020Supersedes22-1931-1G-EN(February2020)©2020Trane。
海悟机柜空调使用说明产品介绍海悟机柜空调,是海悟科技基于信息化产业蓬勃发展,智能化要求不断提升的大数据时代背景下,专为中小型IT机房、中小型通信机房、移动通信基站等应用环境定向开发设计。
经过国家精密空调专业实验室严格测试,具有高效卓越的制冷性能,稳定可靠的运行能力,科技智能的控制操作系统,标准便捷的维护安装特性,适用于满足各类中小型机房设备环境的需求。
使用场所满足全国绝大部分地区,主要适用于中小型计算机房、户外通讯基站、铁路信号站、设备间、电池室、电力间、变电站、各类监控室、小型高科技电子设备机房等精密环境。
产品特点1、采用全新的结构布局设计和多种名优核心零部件,能效比高达3.67。
2、整个系统标况显热比高于92%,极力抑制除湿效果,保证湿度处在合理范围,有效保护电子元件。
3、采用名优压缩机,运动部件少,无高低压阀门,防液击,启动电流小,具有压缩运行延续、平稳、噪音低、寿命长等优点。
4、采用高效EC风机,将新制造工艺及新材料完美运用到核心部件上,通过风机线圈优化设计,有效降低电磁能,热能和机械损耗。
独特的双风机设计,使风场更加均匀,单风机出现故障,可保证另一风机正常工作,有效提高换热效率的同时实现双重保护。
5、采用优质电子膨胀阀,精确调节制冷剂循环流量,控制蒸发器出口过热度,不仅大幅度提高机组效率,同时保证系统稳定可靠运行。
6、采用高效铜管换热器,蓝色亲水膜铝箔低片损翅片和内螺纹铜管完美结合,并且创新采用CFD辅助优化设计,使换热器的换热效率大大提升,耐用更节能。
7、新颖的结构设计,超广角大面积送风,送风角度无级调节,保证空气顺畅流动,加速达到预热温度;创新的外观设计,与服务机柜完美融为一体,高效美观。
8、压缩机内置,减少防盗损失,同时可降低室外机组噪音;室外机防盗报警装置,安全防盗。
9、采用环保制冷剂R410a,降低二氧化碳排放,绿色环保。
10、采用领先的智能管理系统:内置WEB服务软件、数据转换器、精密空调制冷系统,通过WEB服务软件和数据转换器的连接处理,可同时管理32台精密空调,实现状态查询、报警分析、参数设定等远程智能控制功能。
HIROSS恒温恒湿机房精密空调操作手册HIMOD系列xx****科技有限公司技术部2009年01月01日目录第一章HIMOD系列海xx空调概述1.1型号多1.2控制技术先进1.3制冷系统1.4送风系统1.5加湿系统1.6加热系统1.7其它第二章HIMOD系列海xx空调型号含义第三章有关空调的一些资料3.1气流组织方式3.2盖板xx开启方式3.3空调重量3.4机组尺寸及维护空间第四章制冷循环管路示意图4.1风冷却(A型)4.2水冷却(W型)4.3双冷源(D型)4.4单系统(C型)4.5双系统(C型)第五章调速风机调速接线示意图第六章MICROFACE概述6.1概述6.2Microface面板简介6.3LCD液晶显示屏介绍第七章MICROFACE面板的操作第八章控制器的使用8.1控制器(HIROMATIC)概述8.2控制器的操作8.3菜单结构第九章日常维护及特殊维护9.1日常维护9.2特殊维护第十章常见报警及处理10.1低压报警10.2高压报警10.3加湿报警10.4失风报警10.5电加热过热报警10.6显示器发黑10.7空调不制冷附录 1:参数列表附录2:报警内容列表附录3:各菜单项含义第一章HIMOD系列海xx空调概述HIMOD系列海xx空调(HIMOD空调)是当今世界上最先进的机房专用恒温恒湿机房专用精密空调。
随着IT业的突飞猛进的发展,各种布局、面积差别很大的机房如雨后春笋般纷纷出现了,使用环境也不一而同。
为适应各种不同要求的机房,新开发的海xxHIMOD系列空调应运而生。
她是在保留她的前一代产品HIRANGE系列机房空调的优点,又应用了当今世界上提高了的制冷技术及制冷部件制造工艺,使用当今最先进的模块化设计理念生产出来的高科技机房空调产品。
1.1型号多HIMOD空调有多种不同的型号,采用风冷却的A型,水冷却的W型,双冷源的H型和D型(机组即可以自身制冷又可以采用其他冷源),免制冷C型。
各种型号空调均有多种送风方式。
海悟8匹精密空调按装教程
1、吊装内机的时候,内机离房顶距离不得小于1公分,避免机器运行时与墙顶产生共振,内机吊装需考虑千分之五的坡度,接冷凝水的一侧要稍微低一些,避免冷凝水排不出去。
2、安装完内机即可安装冷媒铜管,这是中央空调安装过程中最重要的一个环节。
3、这是焊接完成后必须对铜管进行的压力测试,往铜管内充入一定压力的氮气进行保压。
4、冷凝水管从内机接出后至室外或地漏,至少保持大于百分之一的坡度。
质量较高的安装则是从室内机接出后,就近落地,最后会同其他冷凝水管一起接出室外或地漏。
5、安装外机的时候做到外机风扇出风口必须在50公分内无遮挡物,所有落地脚必须安装减震垫,保证外机运转正常。
6、外机安装完毕后需要对冷媒管进行抽真空,把管内的空气抽出,保持管内干燥、无水分。
7、上述工作完成后,可以开启冷媒阀,释放出外机内自带的冷媒,开机测试并检测压力,适当进行补充,直至调试完成达到理想工作状态后即可。
Air conditioners forCritical Applications精密机房专用空调 CYBERCOOL CYBERCOOL制冷量:7.4kW~100kW Air conditioners forCritical Applications精密机房专用空调机目录前言 (02)基本说明 (02)型号识别 (03)主要特点 (03)电脑控制系统 (05)远程联网监控 (07)技术数据 (08)特殊订货 (13)电力要求 (14)安装技术要求 (14)外型尺寸图 (15)风冷冷凝器基本说明 (31)风冷冷凝器技术参数 (31)风冷冷凝器尺寸图 (32)前 言 CYBERCOOL系列精密空调是阿尔西集团将多年的机房空调生产技术与中国精密空调市场需求相结合而设计、开发、生产的精密机房专用空调机组。
此系列产品服务于对温度、湿度有严格要求的空调场合,这种场合要求设备一年365天,每天24小时全天候运行,因此该系列产品具有极高的可靠性和稳定性及经济性。
基本说明 CYBERCOOL精密机房专用空调机组可适用于通信、卫星、计算机房、数据中心、INTERNET、CT及核磁共振机房等需要恒定温度和湿度、并需对工作环境进行精密控制的高科技场所。
CYBERCOOL精密机房专用空调机组分为三大系列: ⑴ 自含冷源—风冷直接蒸发式机组DXA系列(远置分体式风冷冷凝器)。
安装方便快捷,适用于水源缺乏的地区和无冷却水系统的场所。
⑵ 自含冷源—水冷直接蒸发式机组DXW系列(内置水冷冷凝器)。
适用于有集中冷却水系统的场所。
机组能效比风冷式机组高,因此更节能;机组安装不受室外场地限制。
⑶ 不含冷源—冷冻水型机组CW系列。
该系列机组适用于有中央空调冷冻水系统的场所,利用用户冷冻水进行制冷。
⑷ 对于较大规格的机组(如:S5以上机组),在自含冷源的直接蒸发式机组基础上附加一个冷冻水盘管可以形成双冷源型空调机组。
即:DXA+CW或DXW+CW。
海悟精密空调说明书
海悟机房精密空调,是专门针对大中型IDC计算机机房、通信机房、设备间等应用场所设计的恒温恒湿精密空调产品,旨在保证敏感设备、工业过程设备、通信设备和计算机等设备拥有一个合理的运行环境,机组可选+余种冷却方式,可满足各种类型的产品应用需求。
海悟机房精密空调机组可采用模块化设计,具备出众的节能性、的可靠性。
具备业界/优先/的智能控制技术、反应灵敏、快速组网等功能。
出众的节能性
机组经过优化结构设计,配置多种节能技术设计,具备高能效比、先热比、耗电量低等特点大容量机组采用U型蒸发器,以提高单位体积内的蒸发器的换热面积,换热更充分,能效更明显。
过滤网采取贴合蒸发器布置,增大过滤网面积、减小过滤网风阻,降低了风机的运行功率,过滤更有效。
机组智能群控功能,可依据实际运行情况控制运行机组数量,有效避免竞争运行,减少浪费,实现按需制冷节能有效。
可靠性
机组采用经过优化配置的框架式结构设计,具有结构强度高、抗震性能优异、机身结构合理等特点。
选配精选部件:机组零配件均采用严格的供应标准,供应商必须
为行业知名品牌,关键零配件须有稳定的质量表现,性能可靠高。
机组电控部分采用强弱的分离的优化设计方式,布局更加合理,
强弱电互不干扰,运行更加可靠。
机组各部件布局经过了周密的布置,在保证可全正面维护的同时,将维护相对频繁的部件设计布置于极易操作的位置,设计非常人性化。
机组具备恒温恒湿功能,温度控制精度可达+1°C,相对湿度控制精度可达+5%。
智能控制技术
机组标配RS485智能通讯接口,并且兼容Modbus协议和电总协
议(YD/T1363.3)。
通过智能通讯接口,机组可接入动环监控、DCIM、BMS、远程监控系统等。
网络访问:机组可选配TCP/IP通讯卡,实现SNMP协议通讯和通
过网络IP地址直接访问的功能。
无缝接入物联网:机组采用了具备微处理器的智能控制器,可作
为智能终端向上接入物联网。
先进的负载跟随技术:通过采集每个设备的数据来实时监控整个
机房的热负荷的变化情况并预测其变化趋势,控制投入运行的机组数量,实现整个机房的总制冷量输出跟随负载变化的功能。
快速组网
同一机房内的多台机组可以通过简单的连接建立控制器间的专
有网络,从而组成一整套系统,该系统选择其中任意一台机组的控制
器作为主控制器,这时多台海悟机房精密空调机组就形成一套整体的环境控制系统,可更协调的保护机房环境。