siemens motor 西门子伺服电机样本
- 格式:docx
- 大小:29.77 KB
- 文档页数:5
/sinamicsV90SINAMICS V90高效便捷的伺服系统版本2017.11宣传册Brochure2SINAMICS V90 及 SIMOTICS S-1FL6运动控制的最佳伺服驱动解决方案目录SINAMICS V90 伺服驱动系统 – SINAMICS 和 SIMOTICS 家族的一员伺服驱动系统SINAMICS V90 伺服驱动和 SIMOTICS S-1FL6 伺服电机组成了性能优化,易于使用的伺服驱动系统,八种驱动类型,七种不同的电机轴高规格,功率范围从0.05kW 到7.0kW 以及单相和三相的供电系统使其可以广泛用于各行各业,如:定位,传送,收卷等设备中,同时该伺服系统可以与S7-1500T/S7-1500/S7-1200 进行完美配合实现丰富的运动控制功能。
伺服驱动系统概述 ..................................................03伺服驱动系统优点 ..................................................05SINAMICS V90 伺服驱动系统 的自动化环境 ......................................................... 10SINAMICS V-ASSISTANT 调试工具 ..........................10SINAMICS V90 技术数据与控制特征 .......................12系统一览及接线图 ..................................................15SIMOTICS S-1FL6 技术数据 及扭矩/速度曲线 .................................................... 18SINAMICS V90 和 SIMOTICS S-1FL6 安装尺寸及安装间距 ............................................... 22选型步骤 ...............................................................26SINAMICS V90 和 SIMOTICS S-1FL6 订货数据 (27)3脉冲序列版本 (PTI)PROFINET 版本 (PN)SINAMICS V90 伺服驱动SINAMICS V90 根据不同的应用分为两个版本:1. 脉冲序列版本(集成了脉冲,模拟量,USS/MODBUS )2. PROFINET 通讯版本SINAMICS V90 脉冲版本可以实现内部定位块功能,同时具有脉冲位置控制,速度控制,力矩控制模式。
siemens motor 西门子伺服电机样本西门子(Siemens)伺服电机是一种先进的电机控制技术,广泛应用于工业自动化领域。
本次样本将介绍西门子伺服电机的特点、应用范围和性能优势。
一、特点西门子伺服电机具有以下特点:1. 高精度控制:采用先进的数字化控制技术,能够实现高速、高精度的电机控制,满足复杂工业应用的需求。
2. 可编程性强:西门子伺服电机支持多种编程语言和软件,用户可以根据需求进行编程和控制,实现个性化的应用。
3. 灵活性:伺服电机可以根据需要进行定制和配置,适应不同的工作环境和要求。
4. 稳定性高:西门子伺服电机具有卓越的稳定性和可靠性,能够长时间稳定运行,提高生产效率。
5. 节能环保:采用先进的能效管理系统,能够实现电能的高效利用,减少能源消耗和环境污染。
二、应用范围西门子伺服电机广泛应用于以下领域:1. 机械加工:在数控机床、切割设备、注塑机等机械加工设备中,伺服电机可实现高精度、高速度的运动控制,提高加工质量和效率。
2. 自动化装配:在自动化装配线上,伺服电机用于驱动和控制各类传送带、输送装置、机械手等设备,实现产品的自动化生产。
3. 化工与制药:在化工与制药过程中,伺服电机用于控制反应釜、混合设备、离心机等设备,提高生产过程的精度和可控性。
4. 包装与物流:在包装和物流领域,伺服电机用于控制自动包装线、堆垛机、分拣机等设备,提高包装效率和物流自动化水平。
5. 纺织与印刷:在纺织和印刷生产中,伺服电机用于控制纺织机械、织布机、印刷机等设备,提高生产质量和效率。
三、性能优势西门子伺服电机具有以下性能优势:1. 高功率密度:伺服电机采用先进的设计和制造技术,功率密度高,体积小,适应于空间有限的应用场景。
2. 高可靠性:西门子伺服电机具有高质量的零部件和严格的质量控制,能够在恶劣的工作环境下稳定运行,减少故障概率。
3. 高扭矩密度:伺服电机具有高扭矩密度,能够提供强大的动力输出,满足高负载的应用需求。
西门子伺服电机_蜗轮蜗杆减速机西门子伺服电机选型手册性能特点1.ANRV系列采用单级蜗轮蜗杆传动,也可由两种机座号配合成双级减速传动。
2.箱体、法兰盘、端盖等零件采用优质铝合金压铸而成,外形轻巧美观、结构紧凑、体积小、重量轻,节省安装空间,且不易锈蚀。
3.配套电机采用铝壳电机,散热性能好,安全可靠、效率高、传动平稳、振动小、噪音低。
4.配套动力输出及转矩输出的多种连接结构,满足各种连接需要;箱体外形设计及底脚孔设置布局适应多种安装方式,通用性强。
5.箱体上设置加油孔和放油孔,润滑油定期更换,不宜损耗变质,便于维护保养。
6.由单级蜗杆减速器组合而成的双级蜗杆减速机,具有单级蜗杆减速机的一切优点,可获得较大的传动比。
7.根据用户需要可提供本样本之外的速比和结构形式。
场所条件1.环境温度在-40℃~50℃条件下额定运行。
(0℃以下启动时润滑油要加热到0℃以上)2.海拔不超过1000m。
3.输入转速不大于1500r/min。
4.可用于正反运转,无行业限制ANRV系列蜗轮蜗杆减速电动机型号说明型号说明1.ANRV—蜗轮蜗杆减速机产品代码。
2.整机结构:无代码…单级 E…双级。
3.入轴连接方式:无代码…单输入轴 B…双输入轴 D…带电机输入法兰DB…一端带输入轴,一端带电机输入法兰。
4.产品规格:单级以蜗轮副中心距表示,如75。
双级以两对蜗轮副中心距表示,如40/63。
5.安装型式:单级有B3、B6、B7、B8、V5、V6六种。
双级有AS1、AS2、BS1、BS2、VS1、VS2、PS1、PS2八种。
6.电机功率:配用Y2、YS系列电机,由B5、B14两种安装型式,如2.2(B14)。
(如带输入法兰而没有电机,只填写电机安装型式)。
7.理论传动比:如i=20。
8.附件:A…单输出轴 B…双输出轴 D…防护罩E…转矩臂 F…输出法兰(ANRV40、50、63有F、FB、FL三种形式)。
型号标记选型说明1.为正确选用ANRV系列蜗轮蜗杆减速机,首先应了解以下几点:●负荷条件●使用转速范围或传动比●工作运转情况及环境●安装空间2.确定工作情况系数K1及工作情况修正系数K2根据表一,决定机械负荷种类A、B、C根据运转时间(小时/日)和启动频率(次/小时)从图1中求得工作情况系数K1根据表二,查取工作情况修正系数K23.选定减速机用户须确定工作机输入机械负荷T(转矩),以T乘以工作情况系数K1,再乘以工作情况修正系数K2,即获得减速机应有的输出转矩值,以此为依据,并结合传动比值或输出转数值,选定所需减速机规格。
111LG0 Low-voltage MotorsAnswers for industry.产品样本 D81.5 • 01.20101LG0 低压交流异步电动机目录 Table of Contents总体介绍Overview ........................................................................... 3电机标准Motor standards ................................................................ 5机械特性Mechanical design .............................................................. 6电气特性Electrical design ................................................................. 10变频应用Converter fed application ................................................... 11订货号 MLFB confi guration ............................................................ 12选件Options ............................................................................ 13选型技术数据表Technical data tables .......................................................... 14外形尺寸Dimension drawings ......................................................... 20技术支持资料Technical supporting documentation ................................. 36 证书 Certifi cates.......................................................................372总体介绍 OverviewFeatures of Siemens 1LG0 seriesFrame and terminal box material: Grey cast iron Standard colour: Stone Grey RAL 7030Available in 2,4,6 pole variants with effi ciency class 3 according to GB18613, and effi ciency class IE1 according to IEC60034-30Specifi c wound stators supporting multiple 3PH mains supply voltages at 50Hz or 60Hz Frame sizes: 80mm ~ 355mmRated power range: 0.55kW ~ 315kW at 50Hz Standard mounting types and variations (IEC 60034-7) TEFC with IP55 degree of protection (IEC 60034-5)Overload capacity of 1.5 times rated current for 2 minutes (IEC 60034-1)V-ring as standard on DE rotor shaft for motor with FS 80~FS 132, and oil seal as option; Oil seal as standard for motor with FS160 and above. Anti-condensation heater (space heater) as option Winding protection with PTC and PT100 as optionInsulation class: F, used according to temperature rise B31LG0 系列电动机是全封闭自扇冷却式三相异步电动机,其防护等级为 IP55。
`7804SQN70... / SQN71...SQN74... / SQN75...电动执行器SQN7...电动执行器,可用于中小型燃烧器的风门挡板和燃气或燃油阀控制.SQN7…特别适用于将该执行器与其产品结合到一起使用OEM厂家!使用和功能SQN7…执行器专门被设计用来驱动气燃料阀和风门挡板,这些阀门用于中小型的燃油或燃气燃烧器。
从而达到燃料和助燃空气的最佳混合比.-与P-PI或PID控制器连接,例如RWF40…-直接连接不同型号的燃烧控制器,例如LOA..,LMO…,LMG…或LFL…-与1或2线控制器或3位控制器连接•所有执行器的功能:: - 耐压和抗热塑料壳体设计- 螺丝接线端子- 带有离合装置的免维护齿轮机构- 内置定位标示- 便于调整的限位开关和辅助开关- 集成电路回路•保持转矩- SQN70... / SQN71... / SQN75...- SQN74...0.7...1.3 Nm0.7 Nm•运行时间: - SQN70... / SQN71... / SQN75...- SQN74...4...30 s4 s•旋转方向- SQN70... / SQN74...- SQN71... / SQN75...逆时针方向顺时针方向• SQN74.../SQN75... - 固定孔和线缆穿入孔-Page1Siemens Building Technologies警告为避免人员伤害,财产损失和环境破坏,必须遵守以下警告注意事项!不要打开、干扰或是修改电动执行器!• 所有过程 (装配、安装和维修工作等必须由专业人员进行。
• 改变执行器连接区域里任何电线连接前,将装置完全与主电源隔离(拆除所有极线• 给连接末端做好充分的保护措施,确保不受到电击危险。
• 检查并确保电线正确连接• 跌落或震动将破坏安全性能。
将不能再继续使用,即使它们外观没有受到任何损坏。
装配注意事项•确保符合相关国家安全规则调试注意事项•调试装置前,检查并确认电线正确连接。
C a t a l o g C o m m o n S e r v o /S p i n d l e M o t o r s F o r C N C F r o m 2007motion control上海晟锐自动化科技有限公司021-********公特長限主軸馬達 (Asynchronous Spindle motor)特長° 全系列皆具有簡潔的長度尺寸° 整合式端子合設計,體積迷你化 (SH100-SH160)° 高轉速應用到達 9000 轉 (選配可達 12000 轉)° 即使在靜止間也可以全扭力輸出應用範圍° 泛用型工具機應用° 精密複合型的切削中心機以及車床° 特殊專用機° 印刷工業應用於印刷機構驅動° 橡膠,塑膠,抽線線以及玻璃生產製造應用° 馬達繞線機以及線圈製造應用規格範圍° 安裝形式 根據 EN 60034-7 (IEC60034-7)IM B3 (IM V5,IM V6),IM B5(IM V1,IM V3,僅 1PH710 到1PH713 適用) IM B35 (IM V15,IM V36)° 線圈接點:Star° 3.7-100 kW (5-134 HP)° 最高可能轉速 12000 轉° 23.6-750 Nm (17.41-553.2 lb f -ft)° 增量式編碼器弦波 1Vpp / 絕對式編碼器 EnDat / 增量式 HTL 1024 pules (每轉) /2048 pules (每轉) ° 70-79dB° IP55,風扇 IP54° 強制氣冷° 絕緣溫度等級 F ,冷卻空氣供應溫度為 40℃ ( 104℉) 以下 (EN 60034-1/ICE 60034-1)° (選配:無煙型保護噴漆) ° (選配:整合型齒輪箱)特長° 具軸心貫通孔,切削液可穿過心軸到達刀具前端° 體積小,功率強° 最高轉速 12000 轉 (選配可達18000 轉)° 即使在靜止間,可連續全扭力輸出° 經由冷卻作用防止法蘭面產生的熱應力° 低噪音° 防護等級高° 高旋轉精度應用範圍° 可應用於較嚴苛的工作環境如高溫,粉塵,油污或其他不適合做空氣冷卻的情況° 馬達周圍環境不會受到馬達的熱傳導° 可應用在全包覆式的銑削機台° 直傳式主軸° 適用車床的動力主軸° 適用具有水冷卻設計的各式專用機規格範圍° 安裝形式 根據 EN 60034-7 (IEC60034-7)IM B35 (IM V15, IM V36)° 線圈接點:Star/Delta 切換° 3.7-27 kW (5-36.2 HP)° 最高轉速 12000 轉(選配:18000 rpm)° 24-170 Nm (17.7-125.39 lb f -ft)° 內置環形增量式編碼器弦波 1Vpp/ 256 pules/ 轉° 72dB° IP65,心軸出口 IP55° 有水冷型 (常用) 和油冷型° 絕緣溫度等級 F ,冷卻空氣供應溫度為 30℃ ( 86℉) 以下 (EN 60034-1/ICE 60034-1)無煙型保護噴漆:標準1PH7 系列 高性能主軸馬達1PM4 系列 高性能軸心貫通式水冷主軸馬達常用馬達應用特性介紹动化科技有限公司61246816馬達的特性曲線圖介紹1PM6/1PM4 系列某些馬達特別是 1P M 4/1PM6 本身具有高低轉速線圈,其特性曲線特徵如左圖,在馬達的選擇應用上必須先加以考量根據 IEC60034-1,以S1: 連續運轉負荷的最大可能S6: 以 10 分鐘內的間歇性負荷的最大能力為準。
DC Motors1GG7, 1GH7, 1HS7 and 1HQ7sSupplement DA 12 × July 2001DC MotorsOrder No.:German:E20002-K4012-A101-A2English:E20002-K4012-A101-A2-7600DA 12DC MotorsDA 12 Supplement1GG7, 1GH7, 1HS7 and 1HQ7July 2001Order No.:German:E86060-K5112-E101-A1English:E86060-K5112-E101-A1-7600DC DrivesPreferred Series up to 500 kW Order No.:German:E20002-K4012-A111-A2English:E20002-K4012-A111-A2-7600DA 12.1SIMOREG Chassis ConvertersOrder No.:German:E20002-K4021-A101-A3English:E20002-K4021-A101-A3-7600DA 21Spare Parts for SIMOREG Chassis Converters Order No.:German:E20002-K4021-A900-A4English:E20002-K4021-A900-A4-7600DA 21 ESIMOREG Converter Cabinet Units Order No.:German:E20002-K4022-A101-A3English:E20002-K4022-A101-A3-7600DA 22Automation and DrivesOrder No.:German:E86060-D4001-A100-B5Eng l ish: E86060-D4001-A110-B4-7600CA 01InternetVisit the Automation and Drives Group in the Internet under the following address:http://www.siemens.de/automationCatalogs of the Automation and Drives Group (A&D)Automation & Drives Catalog Interactive catalogs on CD-ROM•Components for Automation & Drives CA 01•Electrical Installation Technology ET 01Analysis SystemsGas Analysis Equipment for the Process Industry PA 10 Process Analysis, Components for Sample Preparation PA 11 SIPAN Liquid Analysis PA 20Drive SystemsVariable-Speed DrivesDC Motors DA 12 DC Drives Preferred Series up to 500 kW DA 12.1 DC Drives Preferred Series 215 kW to 1500 kW DA 12.2 SIMOREG Chassis Converters DA 21 SIMOREG Converter Cabinet Units DA 22 SIMOVERT PM Modular Converter Systems DA 45 SIEMOSYN Motors DA 48 MICROMASTER 420/440 Inverters DA 51.2 COMBIMASTER 411/MICROMASTER 411DA 51.3 SIMOVERT A Current-Source DC Link Converters DA 62 SIMOVERT MV Medium-Voltage Drives DA 63 MICROMASTER, MIDIMASTER DA 64 Low-Voltage Motors for Variable-Speed Drives DA 65.3 SIMOVERT MASTERDRIVES Vector Control DA 65.10 SIMOVERT MASTERDRIVES Motion Control DA 65.11 SIMADYN D Control System DA 99 Automation Systems for Machine Tools SIMODRIVE NC 60•AC Main Spindle Motors 1FE1, 1PH2, 1PH3, 1PH4,1PH7•AC Servomotors 1FK6, 1FT5, 1FT6•AC Linear motors 1FN1, 1FN3•Converter System SIMODRIVE 611•Converter Systems SIMODRIVE POSMO A/CD/CA/SILow-Voltage Three-Phase-Motors•Project Manual M 10•Squirrel-Cage Motors, Totally Enclosed, Fan-Cooled M 11 Drive and Control Components for Hoisting Equipment HE 1 Automation Systems for Machine ToolsSINUMERIK & SIMODRIVE NC 60 Cables, Connectors and System Components NC Z Human Machine Interface Products/SystemsSIMATIC HMIST 80SIMATIC Industrial Automation SystemsSIMATIC PCS Process Control System ST 45 SIMATIC S5/PC/505 Automation Systems ST 50 Components for Totally Integrated Automation ST 70 Supplementary Components ST 71 SIMATIC PCS 7 Process Control System ST PCS 7 Electrical Installation TechnologyProtective Switching and Fuse SystemsBuilding Management Systems with instabus EIBI 2.1Program Overview Modular Devices I 2.11 STAB Wall-Mounting Distribution Boards I 2.31 SIKUS Floor-Mounting Distribution Boards I 2.328PU Busway System I 2.36Systems Engineering Catalog Power supplies SITOP power KT 10.1 System cables SIMATIC TOP connect KT 10.2 MOBY Identification Systems KT 21 Industrial Microcomputers SICOMP KT 51 Printers and Monitors for Automation and Drives KT 61 Cabinet Packaging System for SIMATIC PCS 7KT 71Industrial Communication and Field Devices IK PILow-Voltage Controls and DistributionLow-Voltage Controlgear, Switchgear and Systems NS K Communication-Capable SIRIUS NET Controlgear,Controlgear, SIGUARD Safety Systems,Control and Signalling Devices, Switchgear,Transformers and DC Power Supplies,Main- and EMERGENCY-STOP Switches,Control Switches, Terminal BlocksSIGNUM Metallic 3SB3Products and Systemsfor Low-Voltage Power DistributionNS PS SENTRON WL NS WLTELEPERM M Process Control SystemAS 235, AS 235H and AS 235K automation systems PLT 111AS 388/TM and AS 488/TM automation systems PLT 112OS 525 operating and monitoring system PLT 122 Operating and monitoring with WinCC/TM PLT 123CS 275 bus system PLT 130Process EngineeringField Instruments for Process AutomationMeasuring Instruments for Pressure,Differential Pressure, Flow, Level and Temperature,Positioners and Liquid MetersFI 01SITRANS LR FI 01 SIWAREX Weighing Systems KT 30 Process Recorders and Accessories MP 20 SIPART, Controllers and Software MP 31Vacuum Pumps/CompressorsOil-Free Vacuum Pumps, Compressors (Blowers),Radial Blowers, Liquid PumpsPVPumpsVacuum Pumps and Compressors, System ELMO-F Cat. Sheets PF Vacuum Pumps and Compressors, System ELMO-G Cat. Sheets PGSIPOS Electric ActuatorsElectric Rotary, Linear and Part-turn Actuators MP 35 Electric Rotary Actuators for Nuclear Plants MP 35.1/.2System SolutionsApplications, Products and Services for Industry SL 01 Automation Solutions in the Plastic Industry•with SIMATIC S7SL 10•with SIMATIC S5ST 58A&D/U3/En 18.04.01Siemens AGAutomation and Drives GroupLarge Drives DivisionP.O. Box 47 43, 90025 NurembergFederal Republic of Germanyhttp://www.siemens.de/automation/ldSiemens Aktiengesellschaft Order No. E86060-K5112-E101-A1-7600sDC Drives DC Motors 1GG7, 1GH7, 1HS7 and 1HQ7 Supplement DA 12 · July 2001DC Motors 1GG7, 1GH7, 1HS7, 1HQ7Supplement DA 12 July 2001IntroductionTechnical FeaturesSelection and Ordering Data Engineering Instructionss32145Dimension DrawingsAppendixAPlease note:The technical data is provided for general information only.When mounting, operating and servicing the equipment, the Instruction Manuals and the information provided on the products themselves must be observed.We reserve the right to revise technical data, selection and ordering data (Order Nos.), accessories and the availability.All of the dimensions in this Catalog are in mm.© Siemens AG 2001Siemens Supplement DA 12 · July 20011/111/2Applications1/4Recommendations for Drive Selection 1/5Overview of Motor Types and Rated Data 1/6DiagramsSiemens Supplement DA 12 · July 2001DC Motors1IntroductionSiemens DC drives distinguish themselves as follows:•Their excellent steady-state and dynamic control response •Their wide range with high control precision•The high efficiency of the complete drive system.The modular DC motors from Siemens are well-proven in combination with driveconverters as variable-speed drives in almost all sectors of industry.This secures competitivestrengths and efficiency for our customers – within Germany and internationally.For example •In mining•In rolling mills•In the printing industry •In the textile and man-made fiber industries •For cranes•In basic industrySIMOREG drive converters.Our DC drives are the optimum solution, no matter which functions have to be fulfilled in drive, power or process engineering.DC MotorsIntroduction1Siemens Supplement DA 12 · July 20011/3Siemens Supplement DA 12 · July 2001DC Motors1IntroductionDetermine the required product profile :Supply voltage DutyDegree of protection Speed range OutputType of construction 3-ph 400, 500 or 690 V ,50/60 Hz1 quadrant/4 quadrant IP ............ n =............rpm P = ............ kWIMPage 2/2 and 3/2 onwardsInstallation conditionsAmbient temperature 40 °C Site altitude1000 mAmbient temperature > 40 °C Site altitude > 1000 m Determining the factors for output and speed changePage 4/2Determine therated armature voltageSupply configuration Duty 3 AC 50/60 Hz 400 V 1Q 3 AC 50/60 Hz 400 V 4Q 3 AC 50/60 Hz 500 V 1Q 3 AC 50/60 Hz 500 V 4Q 3 AC 50/60 Hz 690 V 1Q 3 AC 50/60 Hz 690 V4QRated armature voltage 470 V DC 420 V DC 600 V DC 520 V DC 810 V DC 720 V DCDetermine the Motor Order No.Determine the motor Order No.in accordance with the"Selection and Ordering Data"Pages 3/2 to 3/35Adapt the speed if necessary n = n Nn < n NSpeed adapted via armature control U a = U an · n / n N P = P N · n / n Nn > n NSpeed adapted via field weakening U a = constant P = constantComplete the motor Order No.Options and short codes for special featuresPages 3/39 to 3/41Select the SIMOREG drive converter and the supply componentsFor Order No. of the drive converter and the supply components,see Catalogs DA 21 and DA 22These❝Recommendations for drive selection ❞guide you step-by-step through this CatalogSiemens Supplement DA 12 · July 20011/5DC Motors1Introduction1/6Siemens Supplement DA 12 · July 2001DC Motors1Introduction$1 . . 351%1 . . 352&1 . . 353(1 . . 354)1 . . 355*1 . . 401+1 . . 402,1 . . 403-1 . . 404.1 . . 405/1 . . 45101 . . 45211 . . 45321 . . 45431 . . 455Siemens Supplement DA 12 · July 20012/122/2Standard versions 2/3Mechanical designs 2/3StandardsSiemens Supplement DA 12 · July 2001DC Motors 1GG7, 1GH7, 1HS7, 1HQ72Technical FeaturesTechnical design formotors of Series1G . 7The internally cooled,separately ventilated DC motors 1G . 7 and 1H . 7are fully laminated and compensated. They represent the optimum solution for every drive application as a result of theirmodular design regarding terminal box and separately-driven fan mounting.Standard Type Description Design All IM B3Degree of protection1GG71GH71HS71HQ7IP 23IP 23IP 54IP 54Cooling type1GH71GG71HS71HQ7IC 17IC 06IC W37 A86IC A06 A66Terminal boxPosition Alignment Cable entry All All All RightCable entry from below UndrilledCoolingSep. ventilated Sep. ventilated Closed-circuit coolingClosed-circuit cooling 1GG71GH71HS71HQ7Separately driven fan, top, NDE ExternalAir-to-water heat exchanger, top Air-to-air heat exchanger, top StatorDesign FeaturesAll All RectangularNo housing, fully laminated Duct connection 1GH7On one side, NDE right Paint finish All RAL 7016BearingsAllRoller bearing with regreasing device Vibration severity grade All NShaft end All With keyway acc. to DIN 6885, Sheet 1Balancing All Half-key balancing Field control range All 1.15 x n N Excitation Type VoltageAll All External 310 VWinding type All With compensation winding Number of polesAll4-poleFor design variants and accessories, see Options, Pages 3/39 to 3/41.Siemens Supplement DA 12 · July 2001DC Motors 1GG7, 1GH7, 1HS7, 1HQ72Technical FeaturesPractically spark-freecommutation when fed from drive converters is achieved as a result of the optimum motor design, even in the overload range. This results in extremely long brush lifetimes.Even critical applications can be handled by selecting suitable brush materials.The noise levels of the motors are determined in accordance with DIN EN 21 680 and they lie far below the values permitted according to DIN EN 60 034-9. This is achieved as a result of the mechanical design and by optimizing the magnetic circuit and the separately-driven fan.Noise levels can be provided on request.The motor bearings are provided with regreasing devices.The locating bearing is at the non drive end.The motors comply with all of the relevant standards and specifications, see adjacent table.As a result of the fact that in many countries the national regulations have beencompletely harmonized with the international IEC 60 034-1 recommendation, there are no longer any differences with respect to cooling medium temperatures, insulation classes and maximum temperature rises.Brush materials, commutation Noise levelsBearingsStandards, specifications, requirements TitleDIN/ENIECGeneral specifications for rotating, electrical machinesDIN EN 60 034-1IEC 60 034-1,IEC 60 085Terminal designations and direction of rotation for electrical machines DIN VDE 0530, Part 8IEC 60 034-8Types of construction DIN EN 60 034-7IEC 60 034-7Built-in thermal protection –IEC 60 034-11Cooling types forrotating electrical machinesDIN EN 60 034-6IEC 60 034-6Degrees of protection of rotating electrical machines DIN EN 60 034-5IEC 60034-5Vibration severity ofrotating electrical machines DIN EN 60 034-14IEC 60 034-14Cylindrical shaft ends for electrical machines DIN 748-3IEC 60 072Noise limit values ofrotating electrical machinesDIN EN 60 034-9IEC 60 034-9DC Motors 1GG7, 1GH7, 1HS7, 1HQ7 Technical Features2Siemens Supplement DA 12 · July 2001Siemens Supplement DA 12 · July 20013/13Ordering DataDC Motors 1GG7, 1GH7, 1HS73/2•Rated supply voltage 3-ph. 400 V AC Rated armature voltage 420 V DC,4 quadrant operation3/5•Rated supply voltage 3-ph. 400 V AC Rated armature voltage 470 V DC,1 quadrant operation3/8•Rated supply voltage 3-ph. 500 V AC Rated armature voltage 520 V DC,4 quadrant operation3/11•Rated supply voltage 3-ph. 500 V AC Rated armature voltage 600 V DC,1 quadrant operation3/14•Rated supply voltage 3-ph. 690 V AC Rated armature voltage 720 V DC,4 quadrant operation3/17•Rated supply voltage 3-ph. 690 V AC Rated armature voltage 810 V DC,1 quadrant operation DC Motors 1HQ73/19•Rated supply voltage 3-ph. 400 V AC Rated armature voltage 420 V DC,4 quadrant operation3/22•Rated supply voltage 3-ph. 400 V AC Rated armature voltage 470 V DC,1 quadrant operation3/25•Rated supply voltage 3-ph. 500 V AC Rated armature voltage 520 V DC,4 quadrant operation3/28•Rated supply voltage 3-ph. 500 V AC Rated armature voltage 600 V DC,1 quadrant operation3/31•Rated supply voltage 3-ph. 690 V AC Rated armature voltage 720 V DC,4 quadrant operation3/34•Rated supply voltage 3-ph. 690 V AC Rated armature voltage 810 V DC,1 quadrant operation3/36Supplementary data for selection 3/39Options3Selection and Ordering DataOutputrangeRatedoutputRated speed Order No.Rated torque Max. fieldweakening speedRated current EfficiencyPNnNMnnFmaxINh kW kW rpm Nm rpm A% 197103 1 . . 7 455-5NA . . -1VV11827041259578204138 1 . . 7 454-5NA . . -1VV11411555059580206173 1 . . 7 453-5NA . . -1VV11137069058583208210 1 . . 7 452-5NA . . -1VV1946084058084210254 1 . . 7 451-5NA . . -1VV17895102058085226119 1 . . 7 455-5NB . . -1VV11813547665581230171 1 . . 7 405-5NA . . -1VV11285051064083232158 1 . . 7 454-5NB . . -1VV11402563065083235225 1 . . 7 404-5NA . . -1VV1997068064085236275 1 . . 7 355-5NA . . -1VV1820071064086236238 1 . . 7 452-5NB . . -1VV1947095064086236196 1 . . 7 453-5NB . . -1VV11150078565085238344 1 . . 7 354-5NA . . -1VV16610103063587238288 1 . . 7 451-5NB . . -1VV17890115064087240416 1 . . 7 353-5NA . . -1VV15510125063588240335 1 . . 7 402-5NA . . -1VV16850100064087240284 1 . . 7 403-5NA . . -1VV1810085064586242492 1 . . 7 352-5NA . . -1VV14700148063589242412 1 . . 7 401-5NA . . -1VV15600124064088244580 1 . . 7 351-5NA . . -1VV14000174063590258134 1 . . 7 455-5NC . . -1VV11840053573582262196 1 . . 7 405-5NB . . -1VV11277059071585264178 1 . . 7 454-5NC . . -1VV11416571073084266322 1 . . 7 451-5NC . . -1VV17865129071088266268 1 . . 7 452-5NC . . -1VV19515107071587266256 1 . . 7 404-5NB . . -1VV1993077071587266220 1 . . 7 453-5NC . . -1VV11149588072586268392 1 . . 7 354-5NB . . -1VV16530118071088268314 1 . . 7 355-5NB . . -1VV1815094572586270320 1 . . 7 403-5NB . . -1VV1806096071588272565 1 . . 7 352-5NB . . -1VV14590169071589272475 1 . . 7 353-5NB . . -1VV15470143071589272380 1 . . 7 402-5NB . . -1VV16850114071589274660 1 . . 7 351-5NB . . -1VV13960183071590274468 1 . . 7 401-5NB . . -1VV15600140071589290151 1 . . 7 455-5ND . . -1VV11834060581583298200 1 . . 7 454-5ND . . -1VV11416080082085300224 1 . . 7 405-5NC . . -1VV11279067081086302350 1 . . 7 355-5NC . . -1VV18240105080088304438 1 . . 7 354-5NC . . -1VV16630131080089304364 1 . . 7 451-5ND . . -1VV18000131081088304302 1 . . 7 452-5ND . . -1VV19645119081588304292 1 . . 7 404-5NC . . -1VV1995088080588304248 1 . . 7 453-5ND . . -1VV11166099082587 225250300Separate ventilation usingStand., radially-mounted, sep.-driven fan G GSeparately-mounted, sep.-driven fan G HMounted air-to-water heat exchanger H SExciting voltage180 V1200 V (Order No. + Short Code L5A)9310 V4360 V7Type of constructionIM B30IM B 35 (on request)Field weakeningThe order numbers for themotors are applicable for fieldweakening speeds nFto 1.15 ·nN. For higher field weakeningspeeds, additional short codesare necessary, i.e. "C05"for nF> 1.15 ·nNto 1.7 ·nNand "C06" for nF> 1.7 ·nN.The motors can be operated atrated output PNup to the fieldweakening speed nFmax.Forhigher speeds, the output mustbe reduced.DC Motors 1GG7, 1GH7, 1HS7Siemens Supplement DA 12 · July 20013Selection and Ordering DataSiemens Supplement DA 12 · July 2001DC Motors 1GG7, 1GH7, 1HS7Output range Rated output Rated speed Order No.Rated torque Max. fieldweakening speed Rated current Efficiency P N n N M n n Fmax I N h kWkW rpm Nm rpm A %306530 1 . . 7 353-5NC . . -1VV15510154080090308735 1 . . 7 351-5NC . . -1VV14000181080091308625 1 . . 7 352-5NC . . -1VV14710167080090308432 1 . . 7 402-5NC . . -1VV16800130080589310530 1 . . 7 401-5NC . . -1VV15600160080590310364 1 . . 7 403-5NC . . -1VV18130109081589338177 1 . . 7 455-5NE . . -1VV11824072092086340252 1 . . 7 405-5ND . . -1VV11289076090588344835 1 . . 7 351-5ND . . -1VV13940182089091344500 1 . . 7 354-5ND . . -1VV16570135090090345328 1 . . 7 404-5ND . . -1VV11005098090589345232 1 . . 7 454-5NE . . -1VV11414093092588346605 1 . . 7 353-5ND . . -1VV15460151090090346400 1 . . 7 355-5ND . . -1VV18260117091589348710 1 . . 7 352-5ND . . -1VV14680164090091348484 1 . . 7 402-5ND . . -1VV16850146090091348406 1 . . 7 403-5ND . . -1VV18190122090490350590 1 . . 7 401-5ND . . -1VV15650160090091350418 1 . . 7 451-5NE . . -1VV17995132091090350348 1 . . 7 452-5NE . . -1VV19635120092090350288 1 . . 7 453-5NE . . -1VV111605108092589375675 1 . . 7 401-5NE . . -1VV15300164096092382555 1 . . 7 402-5NE . . -1VV16850146098591382464 1 . . 7 403-5NE . . -1VV17860133099091382288 1 . . 7 405-5NE . . -1VV112670860101088384375 1 . . 7 404-5NE . . -1VV197801130101090394960 1 . . 7 351-5NE . . -1VV139201760101092395462 1 . . 7 355-5NE . . -1VV181701140103090396575 1 . . 7 354-5NE . . -1VV165801310102091398695 1 . . 7 353-5NE . . -1VV154701460102092400820 1 . . 7 352-5NE . . -1VV146601590102092408215 1 . . 7 455-5NF . . -1VV118125790109088415282 1 . . 7 454-5NF . . -1VV114005935109089420505 1 . . 7 451-5NF . . -1VV179601290108092420418 1 . . 7 452-5NF . . -1VV195751180108591420348 1 . . 7 453-5NF . . -1VV11152510501095904341060 1 . . 7 351-5NF . . -1VV139001780110093440640 1 . . 7 354-5NF . . -1VV165701320113092440510 1 . . 7 355-5NF . . -1VV182401150114091440326 1 . . 7 405-5NF . . -1VV112900960115090444770 1 . . 7 353-5NF . . -1VV155101470114092445910 1 . . 7 352-5NF . . -1VV146701600114092445424 1 . . 7 404-5NF . . -1VV11003011401150914487651 . . 7 401-5NF . . -1VV156001570114092325350400Separate ventilation usingStand., radially-mounted, sep.-driven fan G G Separately-mounted, sep.-driven fan G H Mounted air-to-water heat exchangerH SExciting voltage180 V1200 V (Order No. + Short Code L5A )9310 V 4360 V7Type of constructionIM B3IM B 35 (on request)Field weakeningThe order numbers for the motors are applicable for field weakening speeds n F to 1.15 · n N . For higher field weakening speeds, additional short codes are necessary, i.e. "C05" for n F > 1.15 · n N to 1.7 · n N and "C06" for n F > 1.7 · n N .The motors can be operated at rated output P N up to the field weakening speed n Fmax. For higher speeds, the output must be reduced.3OutputrangeRatedoutputRated speed Order No.Rated torque Max. fieldweakening speedRated current EfficiencyPNnNMnnFmaxINhkW kW rpm Nm rpm A% 450625 1 . . 7 402-5NF . . -1VV169001410115092450524 1 . . 7 403-5NF . . -1VV1820012801160914881210 1 . . 7 351-5NG . . -1VV138501*********492870 1 . . 7 401-5NG . . -1VV154001*********495375 1 . . 7 405-5NG . . -1VV112610*********498485 1 . . 7 404-5NG . . -1VV198101170128092500610 1 . . 7 451-5NG . . -1VV178001040127093500600 1 . . 7 403-5NG . . -1VV179701310127092500585 1 . . 7 355-5NG . . -1VV1816011501290925051030 1 . . 7 352-5NG . . -1VV146801*********505880 1 . . 7 353-5NG . . -1VV154701*********505735 1 . . 7 354-5NG . . -1VV165601320128093505715 1 . . 7 402-5NG . . -1VV167501430128093505510 1 . . 7 452-5NG . . -1VV194751150129092505264 1 . . 7 455-5NG . . -1VV118270755133090510424 1 . . 7 453-5NG . . -1VV1115151020131092510344 1 . . 7 454-5NG . . -1VV1141609001320915151370 1 . . 7 351-5NH . . -1VV135901*********5451170 1 . . 7 352-5NH . . -1VV144501650138094550665 1 . . 7 355-5NH . . -1VV179001170140093555995 1 . . 7 353-5NH . . -1VV153401490140093555975 1 . . 7 401-5NH . . -1VV154501550140094555830 1 . . 7 354-5NH . . -1VV164101340141093555420 1 . . 7 405-5NH . . -1VV1126209401420925651600 1 . . 7 351-5NJ . . -1VV133702100142094565800 1 . . 7 402-5NH . . -1VV167501390143093565545 1 . . 7 404-5NH . . -1VV199101120144092570672 1 . . 7 403-5NH . . -1VV1810012501440936051360 1 . . 7 352-5NJ . . -1VV142501880152094605765 1 . . 7 451-5NH . . -1VV175451270153093615640 1 . . 7 452-5NH . . -1VV192051150156093625965 1 . . 7 354-5NJ . . -1VV161701540158093625775 1 . . 7 355-5NJ . . -1VV177001340158093625530 1 . . 7 453-5NH . . -1VV1112601020159593625430 1 . . 7 454-5NH . . -1VV113870895160092625330 1 . . 7 455-5NH . . -1VV1180907501620916301190 1 . . 7 401-5NJ . . -1VV1505017801580946301160 1 . . 7 353-5NJ . . -1VV151901680168094655980 1 . . 7 402-5NJ . . -1VV164001580164094670822 1 . . 7 403-5NJ . . -1VV177801430169094670520 1 . . 7 405-5NJ . . -1VV1123001090170092675670 1 . . 7 404-5NJ . . -1VV196201270171093680880 1 . . 7 451-5NJ . . -1VV173951290170594685730 1 . . 7 452-5NJ . . -1VV189351170172594685610 1 . . 7 453-5NJ . . -1VV1107251060173094695382 1 . . 7 455-5NJ . . -1VV117370770178092705496 1 . . 7 454-5NJ . . -1VV113570905179093 450550600700Separate ventilation usingStand., radially-mounted, sep.-driven fan G GSeparately-mounted, sep.-driven fan G HMounted air-to-water heat exchanger H SExciting voltage180 V1200 V (Order No. + Short Code L5A)9310 V4360 V7Type of constructionField weakeningThe order numbers for themotors are applicable for fieldweakening speeds nFto 1.15 ·nN. For higher field weakeningspeeds, additional short codesare necessary, i.e. "C05"for nF> 1.15 ·nNto 1.7 ·nNand "C06" for nF> 1.7 ·nN.The motors can be operated atrated output PNup to the fieldweakening speed nFmax.Forhigher speeds, the output mustbe reduced.3Output range Rated output Rated speed Order No.Rated torque Max. fieldweakening speed Rated current Efficiency P N n N M n n Fmax I N h kWkW rpm Nm rpm A %226119 1 . . 7 455-5NA . . -1WV11813547659080232158 1 . . 7 454-5NA . . -1WV11402563058583236197 1 . . 7 453-5NA . . -1WV11144079058584238290 1 . . 7 451-5NA . . -1WV17865116057586238240 1 . . 7 452-5NA . . -1WV1951096058585260195 1 . . 7 405-5NA . . -1WV11273059063585260136 1 . . 7 455-5NB . . -1WV11826054566082265180 1 . . 7 454-5NB . . -1WV11406072065585266256 1 . . 7 404-5NA . . -1WV1993077064087268312 1 . . 7 355-5NA . . -1WV1820094064087268326 1 . . 7 451-5NB . . -1WV17850130063588268270 1 . . 7 452-5NB . . -1WV19480108064087268224 1 . . 7 453-5NB . . -1WV11147589565086270390 1 . . 7 354-5NA . . -1WV16610117063589270380 1 . . 7 402-5NA . . -1WV16800114063589270322 1 . . 7 403-5NA . . -1WV1803097064088272555 1 . . 7 352-5NA . . -1WV14680167063590272472 1 . . 7 353-5NA . . -1WV15500142063589272466 1 . . 7 401-5NA . . -1WV15600140063589274655 1 . . 7 351-5NA . . -1WV13990184063590294153 1 . . 7 455-5NC . . -1WV11835061073584300224 1 . . 7 405-5NB . . -1WV11279067072086300202 1 . . 7 454-5NC . . -1WV11418581073086302355 1 . . 7 355-5NB . . -1WV18120107072088302292 1 . . 7 404-5NB . . -1WV1988088071588302365 1 . . 7 451-5NC . . -1WV17900134071089302302 1 . . 7 452-5NC . . -1WV19520121071588302250 1 . . 7 453-5NC . . -1WV111535100072587304445 1 . . 7 354-5NB . . -1WV16520134071589306540 1 . . 7 353-5NB . . -1WV15420155071590306430 1 . . 7 402-5NB . . -1WV16800129071090306362 1 . . 7 403-5NB . . -1WV18070109071589308635 1 . . 7 352-5NB . . -1WV14630169071590308530 1 . . 7 401-5NB . . -1WV15550159071590310745 1 . . 7 351-5NB . . -1WV13970182072091330173 1 . . 7 455-5ND . . -1WV11824069081585338254 1 . . 7 405-5NC . . -1WV11271076080588338228 1 . . 7 454-5ND . . -1WV11409591082087342496 1 . . 7 354-5NC . . -1WV16590138079590342398 1 . . 7 355-5NC . . -1WV18210120080089344330 1 . . 7 404-5NC . . -1WV1995099080589344412 1 . . 7 451-5ND . . -1WV17995131081090344342 1 . . 7 452-5ND . . -1WV19635119081589345600 1 . . 7 353-5NC . . -1WV15490154080091345282 1 . . 7 453-5ND . . -1WV111685106082588346705 1 . . 7 352-5NC . . -1WV14690168080091348830 1 . . 7 351-5NC . . -1WV140001820800923484881 . . 7 402-5NC . . -1WV16800146080590250300Separate ventilation usingStand., radially-mounted, sep.-driven fan G G Separately-mounted, sep.-driven fan G H Mounted air-to-water heat exchangerH SExciting voltage180 V1200 V (Order No. + Short Code L5A )9310 V 4360 V7Type of constructionIM B3Field weakeningThe order numbers for the motors are applicable for field weakening speeds n F to 1.15 · n N . For higher field weakening speeds, additional short codes are necessary, i.e. "C05" for n F > 1.15 · n N to 1.7 · n N and "C06" for n F > 1.7 · n N .The motors can be operated at rated output P N up to the field weakening speed n Fmax. For higher speeds, the output must be reduced.3OutputrangeRatedoutputRated speed Order No.Rated torque Max. fieldweakening speedRated current EfficiencyPNnNMnnFmaxINhkW kW rpm Nm rpm A% 350600 1 . . 7 401-5NC . . -1WV15550160080591350412 1 . . 7 403-5NC . . -1WV18130124081590384202 1 . . 7 455-5NE . . -1WV11815080592087385370 1 . . 7 404-5ND . . -1WV19950111089590385285 1 . . 7 405-5ND . . -1WV11290086090589388940 1 . . 7 351-5ND . . -1WV13940181089092388565 1 . . 7 354-5ND . . -1WV16560136090091390680 1 . . 7 353-5ND . . -1WV15480151090091390264 1 . . 7 454-5NE . . -1WV11411095092089392805 1 . . 7 352-5ND . . -1WV14650164090092392452 1 . . 7 355-5ND . . -1WV18280117091590392545 1 . . 7 402-5ND . . -1WV16850145090091392460 1 . . 7 403-5ND . . -1WV18160133090291394665 1 . . 7 401-5ND . . -1WV15650160090092394472 1 . . 7 451-5NE . . -1WV17955132091091395392 1 . . 7 452-5NE . . -1WV19600120091591396326 1 . . 7 453-5NE . . -1WV111600108092590422760 1 . . 7 401-5NE . . -1WV15300164096092430625 1 . . 7 402-5NE . . -1WV16850146098592432524 1 . . 7 403-5NE . . -1WV17890132099091432424 1 . . 7 404-5NE . . -1WV197401170100091432326 1 . . 7 405-5NE . . -1WV112660*********4421080 1 . . 7 351-5NE . . -1WV139101*********446650 1 . . 7 354-5NE . . -1WV165501310102092446520 1 . . 7 355-5NE . . -1WV181901140103091448785 1 . . 7 353-5NE . . -1WV154501*********450920 1 . . 7 352-5NE . . -1WV146701*********464244 1 . . 7 455-5NF . . -1WV118160*********470318 1 . . 7 454-5NF . . -1WV114025*********472570 1 . . 7 451-5NF . . -1WV179351290108092474392 1 . . 7 453-5NF . . -1WV1115201050109591475472 1 . . 7 452-5NF . . -1WV1961011801090924861200 1 . . 7 351-5NF . . -1WV138701*********495575 1 . . 7 355-5NF . . -1WV182201140115092496720 1 . . 7 354-5NF . . -1WV165801320113092498870 1 . . 7 353-5NF . . -1WV154601*********498368 1 . . 7 405-5NF . . -1WV112920*********5001020 1 . . 7 352-5NF . . -1WV146801*********500478 1 . . 7 404-5NF . . -1WV199901150115091505860 1 . . 7 401-5NF . . -1WV156001*********505705 1 . . 7 402-5NF . . -1WV168501410115092510592 1 . . 7 403-5NF . . -1WV1824012701160925401360 1 . . 7 351-5NG . . -1WV137901*********545980 1 . . 7 401-5NG . . -1WV153001********* 350400500Separate ventilation usingStand., radially-mounted, sep.-driven fan G GSeparately mounted, sep.-driven fan G HMounted air-to-water heat exchanger H SExciting voltage180 V1200 V (Order No. + Short Code L5A)9310 V4360 V7Type of constructionField weakeningThe order numbers for themotors are applicable for fieldweakening speeds nFto 1.15 ·nN. For higher field weakeningspeeds, additional short codesare necessary, i.e. "C05"for nF> 1.15 ·nNto 1.7 ·nNand "C06" for nF> 1.7 ·nN.The motors can be operated atrated output PNup to the fieldweakening speed nFmax.Forhigher speeds, the output mustbe reduced.。
siemens motor 西门子伺服电机样本作为一家全球知名品牌,西门子在伺服电机这一领域也有着强大的实力和丰富的经验。
西门子伺服电机具有高效稳定、精度高、噪声小、适用范围广等优势,广泛应用于制造业、机械、包装、印刷、激光加工等多个领域。
在大量客户的使用实践中,西门子伺服电机获得了很高的赞誉和好评。
1. 西门子伺服电机的优势
西门子伺服电机采用了独特的技术和处理方式,创造出了高效稳定、精度高、噪声小的特点。
其中,高效稳定表现在伺服电机的速度调节、位置控制、力矩调节等方面,能够实现较高的控制精度,满足客户不同行业需求的高精度、高速度控制;而精度高则是意味着西门子伺服电机的运行准确度不断提高,同时保证了输出功率的质量可靠;噪声小则表现在西门子伺服电机具有优良的噪声抑制性能,降低了工作环境的噪音污染。
西门子伺服电机适用范围广泛,下面来详细介绍一下:
2. 伺服电机的适用范围
2.1 制造业
制造行业中,西门子伺服电机广泛应用于食品加工、化工生产、医药生产、半导体制造等众多方面,针对不同行业需求,提供了量身定制的伺服电机方案。
2.2 机械制造
西门子伺服电机在机械领域的应用,表现在了自动化机械和精密加工领域方面,既保证了生产效率,也提升了机械品质。
2.3 包装行业
在包装行业中,西门子伺服电机在飞达控制、卷标机平移、袋包装控制、标签印刷控制等方面应用广泛,并以其稳定性和高效性得到客户推崇。
2.4 印刷行业
在印刷行业中,西门子伺服电机主要应用于数字印刷以及包装印刷领域,能够实现高精度的位置控制以及高速度的运动,大大提高了生产效率。
2.5 激光加工
激光加工行业作为新兴领域,目前正处于高速发展阶段。
西门子伺服电机的出色表现,成为众多激光设备制造商的首选。
总之,西门子伺服电机应用广泛,能够满足不同领域客户的需求,下面介绍一下西门子伺服电机的应用场景。
3. 西门子伺服电机的应用场景
3.1 自动化控制
西门子伺服电机在工业机械的自动化控制中发挥重要作用,能够通过运动控制、位置控制等手段,实现自动化机械的运转,提升生产效率,保证生产品质。
3.2 文字图形印刷
西门子伺服电机在文字图形印刷领域应用广泛,以其高精度的控制能力,提升了印刷品的制作效率和印刷质量。
3.3 电子设备
在电子设备中,西门子伺服电机能够通过高效稳定的运动控制,实现设备运转、组装、检测等多种功能。
3.4 传动控制
西门子伺服电机在传动控制中能够以其优异的性能,包括运动平稳、响应迅速等优点,更加精准地完成传动控制。
3.5 食品制造
作为食品制造机械的核心部分,西门子伺服电机能够实现高速度、高精度直线或转动运动控制,保证食品生产效率和品质。
4. 结论
通过对西门子伺服电机的介绍,不难发现,其具有广泛的应用领域和极高的技术实力,在多个领域得到了广泛的应用。
我们相信,在市场发展的过程中,西门子伺服电机将会继续以优秀的性能表现,创造更多新的应用模式。