戴尔EqualLogic PS6000S初始化配置指南
- 格式:docx
- 大小:1.11 MB
- 文档页数:19
ELL电脑开机F1问题解决开机显示:Strike tne F1 key to continue,F2 to yun the setup utility摁DEL键进入BIOS,如下根据BIOS厂商不同有两种情况,请对号入座一 AMI BIOS,第一页上显示有时间日期的那种界面1、进BIOS将默认设置改为优化设置。
---摁F5回车即可,AMI不区分这个2、关闭软驱。
----在第一页找到 Floppy 1.44的那个选择,设置成Disable。
3、关闭开机软驱检测功能。
----这里同上即可,不用设置。
4、打开快速启动自检功能 ---默认是开启的,在Boot的大项里的quick boot 选择,设置成Enable就好5、将硬盘设为第一启动---在Boot内找到boot priority,设置1st为HDD二 Award BIOS,屏幕中间有竖线那种界面1、进BIOS将默认设置改为优化设置。
找到Load Setup Defaults回车选择Y2、关闭软驱。
找到Standard CMOS Setup内的Floppy A 1.44那个选择设置成Disable3、关闭开机软驱检测功能。
BIOS Features Setup中修改BootUp Floppy Seek 为Disable4、打开快速启动自检功能 BIOS Features Setup中修改Quick Power On Self Test为Enable5、将硬盘设为第一启动。
BIOS Features Setup中修改BootSequence内1st为HDD你一开机就按DEL进入到BOIS里进行设置一下就可以了,你把第一启动设为硬盘启动就可以了.Boot Order/Boot Sequence 启动顺序(系统搜索操作系统文件的顺序)选择 Advanced BIOS Features 【高级 BOIS 特性设置】,并将 First Boot Device (1st Boot) 【第一启动设备】boisAdvanced BIOS Features------First Boot Device-----CDROM就可以了下面是DELL的BIOS的中英文对照发上来你看看!自己漫漫研究解决吧!Time/System Time 时间/系统时间Date/System Date 日期/系统日期Level 2 Cache 二级缓存System Memory 系统内存Video Controller 视频控制器Panel Type 液晶屏型号Audio Controller 音频控制器Modem Controller 调制解调器(Modem)Primary Hard Drive 主硬盘Modular Bay 模块托架Service Tag 服务标签Asset Tag 资产标签BIOS Version BIOS版本Boot Order/Boot Sequence 启动顺序(系统搜索操作系统文件的顺序)Diskette Drive 软盘驱动器Internal HDD 内置硬盘驱动器Floppy device 软驱设备Hard-Disk Drive 硬盘驱动器USB Storage Device USB存储设备CD/DVD/CD-RW Drive 光驱CD-ROM device 光驱Modular Bay HDD 模块化硬盘驱动器Cardbus NIC Cardbus总线网卡Onboard NIC 板载网卡Primary Master Drive 第一主驱动器Primary Slave Drive 第一从驱动器Secondary Master Drive 第二主驱动器Secondary Slave Drive 第二从驱动器IDE Drive UDMA 支持UDMA的IDE驱动器:使用该选项可以启用或禁用通过内部IDE硬盘接口的DMA传输。
Array ConfigurationRapid EqualLogic Configuration Series Implementation GuideJanuary 2015Revisions© 2012 Dell Inc. All Rights Reserved. Dell, the Dell logo, and other Dell names and marks are trademarks of Dell Inc. in the US and worldwide.All trademarks and registered trademarks mentioned herein are the property of their respective owners.1Establish console accessTo perform this configuration you will need the following:∙A serial null-modem cable with DB9 connectors (provided with the EqualLogic array).∙A management station (server, desktop, or laptop) running Windows (XP, 7, 2003, 2008) in closeproximity to the EqualLogic array (i.e. the serial cable must connect from this system to the storagearray). You may also use a Windows host server for this if one is available.∙A terminal emulator such as HyperTerminal, Putty, or TeraTerm. HyperTerminal is only available inWindows XP and 2003. Putty and TeraTerm can be found for download through a quick internetsearch.∙A range of IP addresses for the storage array. Each new group requires a single IP address, whileeach new storage requires 2-4 IP addresses. Refer to the prerequisites table.∙The name you want to use for the array∙Name of the PS Series group (new or existing)Perform the following array initialization steps using the CLI:1.If not already powered up, turn on the storage array.2.Open your terminal emulator and configure it to use the serial port (usually COM1 but this mayvary depending on your system). Configure serial communications for 9600,N,8,1 and no flowcontrol.3.Connect the serial cable between the management system and the storage array. The cable mustbe connected to the active controller –the active controller will have a green LED labeled “ACT”.4.Shortly after the storage is powered on, a login prompt should appear. If it doesn’t, then hit enterin the terminal emulator.5.Login with username grpadmin and password grpadmin.6.The array will prompt with: Would you like to configure the array now? Type Y.If not prompted, type setup to access the configuration7.When prompted: Do you want to proceed type Y again.8.When prompted with Member Name [ ]: provide a name for the storage array (Hint: this name willappear in Group Manager, so use something meaningful).9.When prompted with Network interface [eth0]: press [Enter].10.When prompted with IP address for network interface [ ]: type the IP address for the first port onthe array (example, 10.10.0.101).11.When prompted with Netmask [255.255.255.0]: type the appropriate network mask, or press[Enter] to accept the default.12.When prompted with Default Gateway [10.10.0.1]: type the appropriate default gateway or press[Enter] to accept the default.13.Next, for Group name [ ]: provide the name of an existing PS Group (used for management of thestorage) that this new array will join, or if this is the first array in a new group, type the name of the new group you want to create.14.When prompted for the Group IP address [ ]: type the IP address of the new group on the SAN, orthe existing group that the array will join (for example, 10.10.0.100, this is not the out-of-band management IP address).15.If prompted with do you want to create a new group (yes|no)[yes]: Press [Enter].16.A summary will display ending with the question, do you want to use the group settings shownabove (yes|no)[yes]: Press [Enter] if the information is correct.17.Enter your password for managing group membership and press [Enter].18.Retype the password for confirmation.19.Enter your password for the default group administration (grpadmin) account and press [Enter].20.Retype the password for confirmation.2Configure the dedicated management port1.The following steps require static IP addresses for management of the array – these must be IPaddresses on a management network (LAN) - not on the SAN. One IP address is required forGroup Management and an additional IP address is required for each array in the group. (Refer tothe Prerequisites table used to collect these IP addresses).2.Activate controller management ports using the following instructions:a.>member select member-name(array1)>eth select X(array1 eth_X)>ipaddress mgmt-port-ip netmask mask(array1 eth_X)>upThis port is for group management only. Make sure it is connected to a dedicated managementnetwork.Do you want to enable the management interface? (y/n) [n]: Y(array1 eth_X)>exit(array1)>exitb.>grpparams( grpparams))>management-network ipaddress mgmt-group-ipThe default management gateway is not configured. You may not be able tomanage this group until you add the default management gateway.Dedicated management network is enabled. You must use the new managementIP address to manage the group.( grpparams))>def-mgmt-gateway ipaddress mymanagementgatewayipaddress( grpparams))>exit3Array configuration: Group Manager1.From the management system (or Windows host), open a web browser and connect to the groupIP address.2.The web browser must have Java Runtime Environment installed and must allow ActiveX controlsto proceed.3.Login as grpadmin and provide the password that was selected during the initial setup.3.1Set required RAID policyComplete the following steps for each member.1.Click on the member in Group Manager that has not been configured to select it.2.When prompted, select Yes to configure RAID for that member then click Next.3.Set the desired RAID policy and accept the default Immediately expand group capacity setting.Click Next to view the summary.4.Click Finish to begin a background initialization of the disks with the selected RAID setting.Continue with the array setup while the initialization completes in the background.3.2Upgrade array controller firmware1.Download the latest array firmware from https:///secure/login.aspx (loginrequired).2.To update array firmware on the member, go to the Maintenance tab and click Update firmware.3.When prompted for a password, supply the grpadmin password.4.Navigate to the downloaded *.tgz file and click Upgrade (or Update) in the Action column.5.Once the update is complete, click Restart in the Action column.6.Group Manager will be temporarily disconnected as the array completes the controller update andrestarts.7.After a few minutes, Group Manager re-connects automatically and reports the Member is up todate.Once the array has restarted, close the web browser to disconnect any Group Manager session and thenopen a new browser session and login again before proceeding.3.3Configure array controller ports1.Select the array.2.Open the Network tab for the member array.3.Double click eth1 and enter the appropriate IP address (documented in the Prerequisites sectionof the preparation document from the Rapid EqualLogic Configuration Portal) and subnet mask,then click the checkbox next to Enable this interface and click OK.4.Repeat for all remaining interfaces. Only select restrict to management access if this port isconnected to a separate management network (not the SAN).3.4Enable SNMP read-only access1.From Group Manager, select Group configuration and click on the SNMP tab.2.Click Add and provide an SNMP community name to be used for read-only access.3.Click OK.4.Click the icon that looks like a diskette to save the configuration.3.5Create volumes1.In the Equallogic PS Series Group Manager, click Volumes on the left toolbar.2.Click create volume.3.Enter volume name and description, and then click Next.4.Enter the Volume size, choose thin or non-thin provision, enter the Snapshot reserve size, andthen click Next.5.Select None (do not allow access), click Skip to end, and then click Finish.。
D6000S User Guide2NOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed.WARNING: A WARNING indicates a potential for property damage, personal injury, or death.© 2021 Dell Inc. All rights reserved.Information in this document is subject to change without notice. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.Trademarks used in this text: Dell and the Dell logo are trademarks of Dell Inc., Intel ®, Centrino ®, Core ™, and Atom ™ are either trademarks or registered trademarks of IntelCorporation in the U.S. and other countries; Microsoft ®, Windows ®, and Windows start button logo are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries; Bluetooth ® is a registered trademark owned by Bluetooth SIG, Inc. and is used by Dell under license; Blu-ray Disc ™ is a trademark owned by the Blu-ray Disc Association (BDA) and licensed for use on discs and players; Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.2021 – 07 Rev.A003Package Contentsa. Dell Universal Dock (D6000S)b. Power adapter and power cordSpecificationsUpstream• USB 3.0 Type A (Via C-to-A converter)• USB-C (Support power delivery up to 65W)Downstream• 3 x USB 3.0 Type A• 1 x USB 3.0 Type A (front, PowerShare)• 1 x USB-C (front, Data only, and PowerShare) • 1 x HDMI• 2 x DisplayPort • Gigabit EthernetSupports USB 3.1 Gen1.• Product capability : product signals at 5 Gbps • Marketing name: SuperSpeed USB• Note: USB 3.1 Gen1 and USB 3.0 terms are synonymousPower LED IndicationNormal working mode: White light Platform standby: Amber light Power Off: Light OffLAN port LED IndicationConnection: Green (Solid green)Active Link: Amber (blinking)abMaximum resolution and refresh rate supported for your display: Note: Maximum Resolution/Refresh Rate will also depend on EDID table of monitorsUSB-C platform users with driver install* If without DisplayLink driver, HDMI out will be from Alt-mode and 4K@ 30Hz.USB-3.0 platform users with driver install** : No Alt-mode support45HDMIEthernetDPDPPower inUSB 3.0USB 3.0USB 3.0USB 3.0USB-CProduct OverviewFront ViewBack ViewRecommended System RequirementsHardwareDL-6xxx devices (4K UHD resolutions)Minimum Requirements for Office, Productivity, WebProcessor: Intel Core i3 2+GHz / Intel Core M / AMD Trinity or betterMemory: 4GBVideo Card: Intel HD 4000, ATI Radeon HD7xxx, NVidia GeForce 5xxM or better,with drivers released specifically for the Windows version.USB: USB 2.0 but USB 3.0 recommendedMinimum Requirements for Full-Screen Video PlaybackProcessor: Intel SkyLake i3 or Intel Core i7 2+GHz / AMD Richland A10-575x / AMDKaveri A10-7400P or betterMemory: 8GBVideo Card: Intel HD 4000, ATI Radeon HD 8650, NVidia GeForce 7xxM or better,with drivers released specifically for the Windows version.USB: USB 3.0Disk: 7200RPM or SSDIf playing UHD content (4K), the system must be capable of decoding the 4Kvideo in the GPU.Operating SystemWins OS (Win 7, 8, 8.1, 10); 32/64 bits (with DisplayLink Driver version: 8.2 onwards).Ubuntu OS 14.04.2 or greater.Chrome OS Build 58 onwards.Recommended 130W Power adapterOperating TemperatureMax. operating temperature is 40o C67Windows 7/8/8.1/10 Setup1. Start to install the drivers first before connecting the Dock to your computer. It is recommended to download the latest drivers from below support website: · /support/drivers · /downloadsNote: Windows will start installing the DisplayLink driver automatically if connected to Internet.2. Follow the screen instructions until the installation is complete.For network/IT administrators, please visit this link for a corporate installation software package. (*User registration required)/corporateinstall/USB-C 3-1-b. Connect your dock and peripherals to your PC.USB-A 3-2-b. Connect your dock and peripherals to your PC.89Features10DisplayLink Manager MenuTo set the display into extended mode1. Click on the DisplayLink icon.2. Select Extend.The device is now extended in the direction it was the last time the display was in this mode. For more control, use the Extend To submenu and select one of the options. This puts the device into extend mode, and places it to the Left/Right/Above/Below the main (primary) monitor.To set the display into mirror mode1. Click on the DisplayLink icon.2. Select Mirror.The resolution, colour depth and refresh rate of the primary screen are replicated onthe monitor connected to the DisplayLink USB Graphics device.Fit to TV configuration1. To configure Fit to TV, choose the option from the DisplayLink GUI.The following interface appears:2. You will also see a red border on the DisplayLink screen.The red border shows the size of the new Windows desktop. Use the “+” and “-”controls on the Fit to TV GUI to change the size of the red border until it fits on the TV screen.Note:Finer configuration of the size of the border can be achieved by holding downthe CTRL key and clicking the “+” and “-”.3. Once the red border is at the edges of the TV screen, click Apply to resize theWindows desktop.FAQs of Dell Universal Dock - D6000SRegulatory InformationDell Universal Dock-D6000S complies with the FCC/CE rules and abides by worldwide regulatory compliance, engineering, and environmental affairs.Contacting Dell:1. Visit /support2. Select your support category3. Select the appropriate service or support link based on your need.Or Visit:/support/.。
Dell DR6000 系统使用入门指南管制型号: E14S Series管制类型: E14S001注、小心和警告注: “注”表示可以帮助您更好地使用计算机的重要信息。
小心: “小心”表示可能会损坏硬件或导致数据丢失,并说明如何避免此类问题。
警告: “警告”表示可能会造成财产损失、人身伤害甚至死亡。
© 2013 Dell Inc. 保留所有权利。
本文中使用的商标: Dell™、Dell 徽标、Dell Boomi™、Dell Precision™、 OptiPlex™、Latitude™、PowerEdge™、PowerVault™、PowerConnect™、OpenManage™、EqualLogic™、Compellent™、KACE™、FlexAddress™、Force10™、Venue™和 Vostro™是 Dell Inc. 的商标。
Intel®、Pentium®、Xeon®、Core®和 Celeron®是 Intel Corporation 在美国和其他国家或地区的注册商标。
AMD®和 AMD Opteron™、AMD Phenom™以及 AMD Sempron™是 Advanced Micro Devices, Inc.的注册商标或商标。
Microsoft®、Windows®、Windows Server®、Internet Explorer®、MS-DOS®、Windows Vista®和 Active Directory®是 Microsoft Corporation 在美国和/或其他国家或地区的商标或注册商标。
Red Hat®和 Red Hat® Enterprise Linux®是 Red Hat、Inc. 在美国和/或其他国家或地区的注册商标。
EqualLogic用户简明手册:1.连线2. 初始化3. 配置4. 修改Group IP1.连线:单控制器的连线就是把所有的网口接到交换机上, 双控制器建议连接两个交换机, 把一个控制器的Eth0, Eth1和另一个控制器的Eth2, Eth3接到一个交换机, 另一个交换机相反接法. (如果是三个网卡, 则忽略Eth3)2.初始化:a.安装随机或下载的HIT软件:b.选择自定义安装:c.选择所有:d.点击完成e.系统提示重新启动, 完成后如图示:f.提示找到存储:g.输入Member信息h.输入Group信息:3.配置: (创建一个Volume给一台服务器访问)a.通过IE访问Group IP:b.选择创建Volumec.输入Volume名字d.选择Volume大小以及策略:e.配置主机访问:f.启用所有网口:g.添加Group IP为iSCSI Target:h.Targets属性:其中VSS-Controller 可以通过以下界面限制访问:i.Logon:j.运行Remote Setup Wizard之Config MPIO:k.选择MPIO配置,Max sessions per volume slice为1-4, 建议为单个Member网口数量, Per entire volume为1-12, 建议为所有Member网口数量l.完成后重新启动服务器, 检查sessions:m.检查MPIO sessions, 看到4个member IP都在使用:4.修改Group IP: 原则: 任何时间点至少有一个网卡和Group IP相同网段a.查看原有Group IP:b.查看Member IP:c.修改网卡IP: 任选一块网卡, 选Modify IP settings:d.修改IP为另一个网段, 如172.168.0.201e.修改默认网关:f.修改Group IP地址: (注意要点右上角的绿色磁盘按钮保存)g.提示保存, 点确定后自动以新的Group IP登录:h.修改其他网卡IP:。
Copyright 2008 Dell, Inc. 版权所有,翻印必究。
Dell 是 Dell Inc. 的商标。
EqualLogic 是注册商标。
本文使用的所有商标和注册商标均属其各自所有者的财产。
本说明文件中的信息如有更改,恕不另行通知。
未经 Dell 书面许可,严禁以任何形式进行复制。
2008 年 7 月部件号码:H695H 修订版 A00ii目录前言 (v)目标读者 (v)组织 (v)说明文件 (vi)技术支持和客户服务 (vi)1 简介.................................................................................................................1-1 PS Series 阵列和组............................................................................................1-1入门步骤............................................................................................................1-32 安装阵列硬件.................................................................................................2-1常规安装建议....................................................................................................2-1防止硬件遭受静电损害..............................................................................2-1网络建议......................................................................................................2-2 PS5000 硬件安装...............................................................................................2-3开始安装 PS5000 之前...............................................................................2-3 PS5000 环境要求........................................................................................2-4 PS5000 包装箱物品....................................................................................2-5 PS5000 机架安装要求..........................................................................2-7安装 PS5000 硬件的步骤...........................................................................2-7第 1 步:将电源电缆连接至 PS5000..................................................2-8第 2 步:将网络电缆连接至 PS5000..................................................2-9第 3 步:打开 PS5000 的电源...........................................................2-10第 4 步:将串行电缆连接至 PS5000................................................2-11 PS5500 硬件安装.............................................................................................2-12开始安装 PS5500 之前.............................................................................2-12 PS5500 环境要求................................................................................2-13PS5500 包装箱物品............................................................................2-14 PS5500 机架安装要求........................................................................2-16iii安装与设置目录iv PS5500 硬件安装步骤..............................................................................2-16第 1 步:将电源电缆连接至 PS5500................................................2-17第 2 步:将网络电缆连接至 PS5500................................................2-20第 3 步:卸下 PS5500 挡板...............................................................2-23第 4 步:解除锁定并打开 PS5500 机箱盖.......................................2-24第 5 步:在 PS5500 中安装磁盘驱动器...........................................2-24第 6 步:关闭并锁定 PS5500 机箱盖...............................................2-26第 7 步:打开电源.............................................................................2-26第 8 步:重新安装 PS5500 挡板.......................................................2-27第 9 步:将串行电缆连接至 PS5500................................................2-273配置软件.........................................................................................................3-1软件配置方法....................................................................................................3-1开始配置软件之前............................................................................................3-2使用设置公用程序............................................................................................3-4使用“远程设置向导”....................................................................................3-6成员 RAID 策略................................................................................................3-6使用 CLI 设置 RAID 策略.........................................................................3-7使用 GUI 设置 RAID 策略.........................................................................3-8 4 使用SAN........................................................................................................4-1创建卷................................................................................................................4-1使用 CLI 创建卷.........................................................................................4-2使用 GUI 创建卷.........................................................................................4-3连接计算机至卷................................................................................................4-6 5 进阶操作.........................................................................................................5-1常用的组自定义任务........................................................................................5-1高级组管理任务................................................................................................5-2索引 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .索引-1前言利用一个或多个 PS Series 存储阵列,可创建 PS Series 组,即自管理的iSCSI 存储局域网 (SAN),无论规模如何,都物美价廉且易于使用。
PS6000 存储阵列机架安装说明部件号:T585M-S-CN修订版1.0版权所有 2008 Dell, Inc. 。
版权所有,翻印必究。
Dell 是 Dell Inc. 的商标。
EqualLogic 是注册商标。
本文使用的所有商标和注册商标均属其各自所有者的财产。
本说明文件中的信息如有更改,恕不另行通知。
未经 Dell 书面许可,严禁以任何形式进行复制。
2008 年 12 月目录简介 (1)开始之前 (1)安装安全预防措施 (1)安装环境要求 (1)机架要求 (2)滑轨套件部件 (3)工具要求 (3)在机架中安装阵列的步骤 (4)步骤 1:更改安装滑轨硬件 (4)步骤 2:确定安装滑轨在机架中所放置的位置 (4)步骤 3:将安装滑轨连接到机架柱上 (5)步骤 4:将机箱滑入到机架中 (7)步骤 5:将机箱连接到安装滑轨 (8)步骤 6:安装挡板 (9)下一步操作 (10)技术支持 (10)简介为了正常操作,PS6000 存储阵列必须要安装在机架中。
关于所支持机架的信息,请联系您的 PS 系列支持提供商。
开始之前在您开始在机架中安装阵列之前,您必须:•阅读安装安全预防措施。
请参阅安装安全预防措施。
•确保机架的位置满足阵列的环境要求。
请参阅安装环境要求。
•确保您的机架满足机架要求。
请参阅机架要求。
•拆封滑轨套件,并且确保您拥有了所有必要的部件和工具。
滑轨套件位于阵列的包装箱内。
您必须自己提供工具。
请参阅滑轨套件部件和工具要求。
安装安全预防措施请遵循这些安全措施:•建议只能由拥有机架安装经验的人员将 PS6000 阵列安装到机架中。
•请确保阵列在任何时候都完全接地,以防止静电释放所带来的损坏。
•处理阵列硬件时,请务必使用阵列附带的静电腕带或采用类似的保护措施。
•从包装箱中提出阵列机箱时,至少需要两名人员。
安装环境要求机架的位置必须满足以下环境要求:•存储设备只能使用电压为 100 至 240 VAC 的电源。
戴尔EqualLogic PS6000S初始化配置指南Dell EqualLogic PS6000S初始化在使用Dell EqualLogic PS6000S之前,我们需要通过串口对其进行初始设置,设置内容包括组管理设置、IP网络设置等方面,下面是设置过程的详细图解。
使用超级终端连接PS6000S首先用串口线连接管理端计算机与PS6000S的控制器的串行端口,接下来便是从管理端向PS6000S发起连接。
由于我们使用的是Windows server 2003,因此在通过串行端口对PS6000S进行设置时首先需要从系统盘安装超级终端,安装完成后运行超级终端,系统会提示输入连接名称,输入名称后确定,选定连接时使用的端口,端口属性参数设置采用默认即可。
输入登录名和密码设置完成后点击确定,连接后在打开的超级终端空白输入框中敲击回车,用户将会看到系统提示输入用户名和密码,在PS6000S出厂设置中,用户名和密码均默认使用grpadmin,输入完成并确定,用户将会收到欢迎信息,并且提示是否现在开始对阵列进行设置。
对于每一步需要进行的操作,系统都会有详细的提示,比如在询问是否要对阵列进行设置时,系统会给出输入y或者是n的提示,需要注意的是,用户在进行输入时需要严格根据提示来进行,比如这里提示的小写的y,用户就不可以输入大写Y,否则会报错。
而在提示后面会有一个方括号,方括号中间的值是默认值,如果默认值与你的选择相同,则直接按回车即可,无需再输入。
设置进程的下一步就是输入Member的名字,这里的Member就是指整个硬件磁盘阵列,在输入名字之后,系统会提示输入网络端口的IP地址,注意,这一步要输入的是要配置的端口名称。
戴尔PS6000S有四个网络端口可供设置,分别是eth0、eth1、eth2、eth3。
这里默认要设置的是eth0,如果用户要设置的就是这个网口,直接回车即可,如果用户要设置的是其他网口,输入网口名称并按回车。
在下一步输入IP地址之后是子网掩码和网关的设置,这里我们均使用默认值,直接回车。
接下来要进行的是组设置,组是一个逻辑概念,是为了管理而设定的,一个组可以包括很多的阵列设备,就像在这一步中系统会提示用户是否要将这个设备加入一个已经存在的组,这时候如果用户确实要加入的话就输入那个组的名称和组的IP地址,如果用户是要重新建立一个组的话可以可以在此输入要建立的组的名字和组IP地址,这个组IP地址要不同于刚才设的具体网口的IP,但最好和网口IP处于一个网段。
这里我们是重新建立一个新的组,输入组名和组IP之后按回车,系统会先在网络中寻找输入的组,如果找不到的话会提示用户是否要建立一个新的组,同意之后系统会询问用户是否要用已经输入的组信息,用户同意之后新的组就建立成功了。
接下来,系统会提示用户修改组管理帐户的密码,输入新密码后PS6000S需要用到串行端口进行的初始化操作就完成了,这时候我们可以看到提示符前面出现PS6000字样,表明我们是对PS6000这个组进行操作。
在这里需要说明的是,PS6000S的两个控制模块并不是对等的,而是一主一备,上述我们进行的操作都是通过主控制模块来完成的,如果用户串口线接入的是备控制端口,用户将会看到系统提示现在接入的只是备控制模块,不能进行阵列和组管理。
在通过串行端口完成初步的初始化之后,用户就可以通过管理端的IE来进行接下来的RAID设置、卷的划分、克隆及快照等等操作了。
通过IE设置戴尔PS6000S使用IE对PS6000S进行管理需要Java的支持,如果用户的管理端计算机上没有安装Java 的话是无法进行管理,这时候就需要到SUN网站去下载一个Java的安装包,安装之后管理端才会有对Java的支持能力。
安装Java软件之后,用户在IE地址栏输入组IP地址即可对存储组进行管理,输入我们刚才设定好的组管理用户名和密码,我们就可以打开组管理主页面,我们可以看到整个管理页面分为左侧的栏目数和右侧的主界面,用户可以在左侧的栏目数中选择要设置的对象,比如组设置、Member硬件阵列设置以及卷设置等等,而在右侧的界面则主要用来显示一下系统信息,比如在主界面显示的就是组名、组IP等。
由于我们还没有进行RAID设置,因此在主界面上有一个很醒目的警告,点击黄色的提示条,系统会出现立即进行RAID设置的提示,点击确定设置即可开始。
下图是进行RAID设置的第一步,用户需要先输入要进行RAID设置的阵列设备的名字,我们先前为这个设备定名为ps6000,输入之后点击下一步。
接下来的一步是设置RAID级别,这款产品支持RAID50、RAID10、RAID5、RAID6四种级别,用户在设置完成后还可以改变RAID级别,但是只能在系统规定的级别之间进行转换,系统在RAID设置出给出了鲜明的提示。
设置完成RAID级别之后系统会将设置信息全部显示以供用户确认,用户确认无误后点击完成,阵列RAID就设置好了。
设置好RAID之后再进入组管理主页面,我们会看到黄色的警告提示已经没有了,而在系统页面中间的组硬盘空间部分,用户可以看到四个四个选项和一个饼图,用户选择不同的选项时都可以从左侧的饼图中看到形象的展示,比如我们现在选的是组空间利用率,我们就会从饼图中看到现在的空间有多少是用来存储卷的,有多少是用来存储快照的,空余的空间又有多少,由于我们现在刚刚完成初始化,还没有设置卷等,所以所有的空间都是空闲的。
当选中第二项RAID空间信息时,我们可以从饼图中看到这个组中采用各种RAID级别的容量比例,不同的RAID级别系统会同不同的颜色标出。
由于我们这个组中只有一个设备,所以大家看到的所有的空间都是RAID50,当一个组中有多个设备且设备使用的是不同的RAID级别时饼图就会显示各种RAID级别空间的比例。
在组管理主页面之下,是组设置项。
点击选中组设置项,我们可以看到在这一项中我们可以对整个组进行设置,包括常规设置、管理设置、通知策略、iSCSI链接策略、SNMP设置、VDS/VSS设置以及等等,在这一项中我们可以进行具体的组设置,比如在第一项常规设置中我们就可以修改组名、组IP并能够设置系统时区以及NA T服务器,其他项目的使用在后面的用到时我们还有详细的介绍。
组设置项下面是组监控项,在这一项中我们可以对连接到这个组的现时情况进行监控,比如第一项就是监控通过iSCSI连接到改组的设备的列表,第二项是用来监控快照等的时间表,而我们图上所显示的是目前对该组进行管理的会话模式,和登陆历史。
第三项Events不用说大家也能看得出来这是日志记录,日志对于管理员来说是非常有用的故障排除等的依据。
第四项是存储池的设置,存储池是PS6000S对资源进行分配的一种方式,与组类似,但比组的范围要小一些,一个组可以拥有多个池,但是一个池中也可以拥有多个阵列,可以说,组更多的是从逻辑上对存储的一个划分,侧重与管理性,而池则更多的是从资源本身上对存储空间进行了划分,侧重于实际使用。
当我们将一个设备进行初始化时,系统会提示是否加入一个组,如果你选择加入一个组后,而这个组内已经存在存储池时,系统还会询问用户是否将这个设备加入该存储池,用户如果选择是,则这个组还是一个存储池,如果选择否,则该组中就有两个存储池了。
在存储池下面的一项是Member,也就是成员的意思,一个Member就是一个单独的物理阵列,在我们这个组中只有一个PS6000,所以Member列表里只有这么一个设备。
选中PS6000,用户就可以对物理设备进行设置了,比如在第一个整体状态项中大家可以看到整个系统的整体状态,比如从上图中大家就可以看到我们在这个阵列中使用了8块硬盘。
而在图形化的硬盘标识右侧的是告警项,如果这个阵列的某一个模块出现问题其会显示黄色的告警信息,在我们这个图里所有的模块都是绿色的OK状态。
而在其他项目也中,比如Network项中,我们可以对设备的四个网口进行设置。
其他的各项从字面意思就很好理解,我们在这里就不一一介绍了。
在Member项下面是卷设置项,在这一项中用户可以进行划分卷、卷克隆、快照等操作,从上面的图我们不难看到目前我们设置了一个卷,这个卷的容量为50G,同样我们还留了50G 的空间来为这个卷的快照所使用并且我们还为这个卷做了一个快照。
具体卷操作我们在后面还有详细说明,这里同样不费笔墨了。
接下来的两项是Volume Collection和Replication Partners,在前者中用户可以为多个卷做集体快照,而后者则是为了容灾备份而设,用户可以将其他设备加为组的Partner,实现容灾备份。
卷操作建立卷我们要为服务器配置存储,还需要将该存储进行卷配置,在这一节我们展示的是如何为戴尔PS6000S配置卷,并且如何使服务器使用卷。
在设置卷之前,我们需要先设置CHAP 帐号,iSCSI设备必须经过握手认证协议(CHAP)才能与服务器进行连接,而在其中CHAP 帐户是必不可少的。
而CHAP帐户首先必须是一个组管理帐户或者是一个池管理帐户,所以我们建立CHAP 帐户的过程也就从建立一个管理帐户开始。
我们再回到一开始的组管理主页面,点击右侧界面中的create account项,或者是选中grop pconlinetestps6000按鼠标右键,从中选择建立帐户。
这时,系统会弹出一个窗口,提示输入账户名和密码,输入之后点击下一步,在这一步中用户可以设置该帐户的权限,有组管理帐户、只读帐户和池管理帐户可供用户选择,我们为了操作方便选择组管理权限,然后点击下一步,在帐户明细中检查无误后点击完成。
这时再看第二项组设置界面中的管理员标签页中我们看到除了原本默认的grapadmin帐户外还出现了新建立的ps6000test用户,同样为组管理员。
接下来我们要做的就是将新建立的用户设置成为CHAP帐户,具体步骤是点击组设置界面中的iSCSI标签页,在下面的Local CHAP Accoount中点击Add,在系统弹出的窗口中输入我们刚刚建立的帐户的用户名和密码,点击确定后即完成,这时在CHAP帐户列表中就可以看到我们刚刚建立的这个帐户了。
大家可能注意到了该界面右上侧的User name和Password,这个帐户是系统自动生成的,类似于超级管理员,这个帐户无需设置就是默认的CHAP帐户,并且用户可以根据自己的需要修改这个帐户的名字和密码。
接下来我们就可以建立卷了。
我们点击volumes项,可以看到界面中会有一个建立卷的项,或者我们在鼠标右键的菜单中也可以找到这一命令,点击建立卷,系统会弹出窗口,在窗口中输入卷名之后点击下一步,在这里我们可以为卷分配空间,并且可以选择为这个卷预留多大的快照空间。
系统默认快照空间是卷的100%,也就是有多大的空间就预留多大的快照空间,而因为快照只是记录卷现有文件的索引表和卷的新增项,因此大多数情况下不会用到像卷那样的空间,因此用户可以根据自己的情况选择预留卷的50%或其他容量为快照做准备。