管径对照表
给水PVC塑料管道的最大支撑间距
(mm)
外径20 25 32 40 50 63 75 90 110 水平管500 550 650 800 950
1100 1200 1350 1550 立管900 1000 1200 1400 1600 1800 2000
2200 2400
塑料给水管径公称外径与直径对照表
公称外径 De 20 25 32 40 50 63 75 90
公称直径 DN 15 20 25 32 40 50 70 80
塑料排水管径公称外径与直径对照表
公称外径 de 50 75 110 160 200
公称直径 DN 50 75 100 150 200
所穿管道的管径和套管对照表(Ⅱ刚性防水套管)
所穿管道的管径 mm 50 75 100 150
防水套管尺寸 mm 114 140 168 219
所穿管道的管径和套管对照表(Ⅲ刚性防水套管)
所穿管道的管径 mm 50 75 100 150
防水套管尺寸 mm 114 140 159 203
所穿给水管道的管径和套管对照表(穿墙、楼板套管)摘自常熟图纸
所穿管道的管径 DN(mm) ≤25 32 40 50 65 80 100 150 防水套管尺寸 DN(mm) 40 50 65 70 80 100 150 200
DN套管外径(m)壁厚(m)套管内径(m)翼板外径(m)翼板面积(m2)翼板厚度(m)翼板重量(kg)套管重量(kg)套管长度(m)共计重量(kg)500.1140.00350.1070.2250.02950.012.31885.240.557.56650.1210.003750.11350.2300.03000.012.35765.960.558.32800.140.0040.1320.2500.03370.012.64367.370.5510.021000.1590.00450.150.2700.03740.012.93449.430.5512.361250.180.0060.1680.2900.04060.013.185914.150.5517.341500.2190.0060.2070.3300.04780.013.755217.330.5521.082000.2730.0080.2570.3850.05790.0125.449628.740.5534.192500.3250.0080.3090.4350.06560.0126.182034.380.5540.563000.3770.010.3570.5000.08470.0149.306249.750.5559.063500.4260.010.4060.5500.09500.01410.440956.400.5566.844000.480.010.460.6000.10170.01411.180863.720.5574.904500.530.010.510.6500.11120.01412.216070.500.5582.715000.590.010.570.7300.14510.01618.220578.630.5596.856000.690.010.670.8300.16700.01620.981292.190.55113.177000.790.010.770.9200.17450.01621.9179105.740.55127.668000.880.010.861.0200.20880.01626.2265117.950.55144.179000.980.010.961.1200.23080.01628.9872131.500.55160.4910001.080.011.061.2300.27200.01634.1635145.060.55179.2212001.290.0121.2661.4300.29890.0246.9317207.910.55254.8414001.490.0121.4661.6300.34290.0253.8334240.450.55294.2816001.690.0141.6621.8300.38680.0260.7351318.100.55378.8418001.90.0161.8682.0400.43300.0267.9819408.660.55476.6420002.10.0162.0682.2400.47700.0274.8837452.040.55526.93刚性防水套管(A型)尺寸、重量表02S404-17页
506080114管径DN刚性防水套管(A形)尺寸、重量表
DN外径D1挡圈外径D2套管外径D3翼环外径D4套管厚度δ翼环壁厚
2253.510
6575.5951212303.7510
8089110140250410
1001081301592704.510
125133155180290610
150159180219330610
200219240273385812
250273295325435812
3003253453775001014
3503774004265501014
4004264454806001014
4504805005306501014
5005305505907301016
6006306606908301016
7007207507909201016
80082085088010201016
90092095098011201016
100010201050108012301016
120012201250129014301220
140014801450149016301220
160016201650169018301420
180018201850190020401620180018201850190020401620
2000202020502100224016注解1:挡圈是焊接在DN管上与套管之间挡填料的挡圈;
注解2:DN是需安装的给排水管;
注解3:20、重量表环壁厚b焊缝K重量(kg)
1044.49
1044.66
1045.33
1056.36
1068.33
10610.06
12615.9
12818.68
141027.4
141030.95
141034.35
141037.85
161044.54
161054.5
161061.43
161069.12
161076.81
161084.5
2012122.5
2012141.3
2014176.4
2016216.62016216.6
239.32016
常用的防水套管分为刚性和柔性。应当指出,防水套管是根据建筑科学研究院开发和设计的S312和02s404标准图集制造的。柔性防水套一般适用于管道穿墙,有振动或防水要求严格的结构。如果穿墙处的墙不是混凝土,则应换成混凝土墙,并且套管必须一次固化在墙中;刚性防水套管适用于饮用水池防水套管的安装,该防水套管是在石棉水泥填满并填充密封膏后进行的,接缝中的所有接触面均应无锈,无油漆和污垢,并且保持清洁干燥。防水套管适用于建筑,化工,钢铁,自来水,污水处理等单位。国家标准防水套管是根据建设部的02s404或S312标准图集选择和生产的,对法兰厚度,法兰环厚度,管径和厚度有严格的要求。非标准表示在外观和总体结构符合标准图集时,在选择材料时放宽了对法兰厚度,法兰环厚度,管道直径和厚度的要求。严格来说,这些产品是不合格的。当然,在一定程度上放宽标准不会影响使用,但是过度放宽标准会影响使用性能!安装防水套管时,应严格按照图册进行预留孔的施工。
防水套管我们听了很多,耳熟能详。产品结构从外观上比较简单,简单的产品在安装中也需要注意很多方面,以下是对安装的小小影响,可以影响产品的内容,可以阅读参考。
1.刚性防水套管适用于铸铁管和非金属管,但有关尺寸应根据管壁厚度进行校正。
2.对翼环和钢套进行加工后,应在外壁涂一次底漆。
3.机壳尺寸表中列出的材料重量是钢制机壳(机壳长度的L值计算为200 mm)和翼环的重量。钢套和翼环由A3材料制成,并用T42焊条焊接。
4.对于套管穿过墙壁的墙壁,如果遇到非混凝土墙壁,则应使用混凝土墙壁。 II型机壳的混凝土浇筑范围应比翼环直径(D4)大200毫米,并且必须一次将机壳倒入墙壁。外壳中的填料应紧密压实。
5.防水套处混凝土墙的厚度不应小于200毫米,否则应加厚墙的一侧或两侧。加厚部分的直径应比翼环(D4)的直径大200毫米。