附录Ⅲ英文翻译A comprehensive overview of substationsAlong with the economic development and the modern industry developments of quick rising, the design of the power supply system become more and more completely and system. Because the quickly increase electricity of factories, it also increases seriously to the dependable index of the economic condition, power supply in quantity. Therefore they need the higher and more perfect request to the power supply. Whether Design reasonable, not only affect directly the base investment and circulate the expenses with have the metal depletion in colour metal, but also will reflect the dependable in power supply and the safe in many facts. In a word, it is close with the economic performance and the safety of the people. The substation is an importance part of the electric power system, it is consisted of the electric appliances equipments and the Transmission and the Distribution. It obtains the electric power from the electric power system, through its function of transformation and assign, transport and safety. Then transport the power to every place with safe, dependable, and economical. As an important part of power’s transport and control, the transformer substation must change the mode of the traditional design and control, then can adapt to the modern electric power system, the development of modern industry and the of trend of the society life.Electric power industry is one of the foundations of national industry and national economic development to industry, it is a coal, oil, natural gas, hydropower, nuclear power, wind power and other energy conversion into electrical energy of the secondary energy industry, it for the other departments of the national economy fast and stable development of the provision of adequate power, and its level of development is a reflection of the country's economic development an important indicator of the level. As the power in the industry and the importance of the national economy, electricity transmission and distribution of electric energy used in these areas is an indispensable component.。
SEISMIC ASSESSMENT OF MEDIUM AND HIGH VOLTAGE POWERSUBSTATION EQUIPMENTSMorteza BastamiAssistant Professor, Dept. of Civil Engineering , University of Kurdistan, Sanandaj, Iran Assistant Professor, Dept. of Civil Engineering , Imam Khomeini International University, Ghazvin, IranEmail: mbastami@uok.ac.ir, mbastami@ABSTRACT :Power electric substations are key elements of power supply systems. Equipments of the power substations have been the most vulnerable components within the power supply systems in past earthquakes. Damage to substation equipments will cause disoperation of whole substation, and then, widespread power disruptions. This paper develops methods for seismic assessment of medium- and high-voltage power substation equipments. In this paper, data of seismic performance of equipments within fifty-eight medium- and high-voltage substations, as the most vulnerable substations, in past major earthquakes in a few countries are collected. The selected equipments are power transformer, live-tank circuit breaker, dead-tank circuit breaker, disconnect switch, current transformer, potential transformer, bus-bar system, lightning arrester, wave trap, and capacitive coupling voltage transformer. In last part of the paper, a damage ratio curve for the medium and high voltage substations is proposed. The obtained results for damage analyses of the equipments indicate that the live-tank circuit breakers by 32.3% are the most vulnerable equipment and dead-tank circuit breakers by 2.5% have the best seismic performance. Current transformers, bus-bar systems, potential transformers, and power transformers are the other vulnerable equipments respectively.KEYWORDS:Power substation, Seismic assessment, Medium voltage, High voltage, Substation equipment1. INTRODUCTIONA power supply system is composed of four sub-systems:power generators, transmission grid, power substations and distribution grid. Supplied power to be useful in a home or business, when it comes off the transmission grid and is stepped-down to the distribution grid. This may happen in several phases. The place, where the conversion from "transmission" to "distribution" occurs, is in a power substation. A power substation typically does three jobs as follows:It has transformers that step transmission voltages (in the tens or hundreds of thousands of volts range) down to distribution voltages (typically less than 20 kV).It has a "bus-bar" that can split the distribution power off in multiple directions.It often has circuit breakers and disconnect switches so that the substation could be disconnected from the transmission grid or distribution lines can be disconnected from the substation when necessary.A high or medium voltage substation is used in a transmission grid but a low voltage substation is employed in a distribution grid. Several large structural systems exist within the substation, each contributing to the overall functionality of the substation. Most of the substation equipments have poor seismic performance. Recent seismic events, such as the 1971 San Fernando (US), 1986 North Palm Springs (US), 1989 Loma Prieta (US), 1990 North of Iran, 1992 Landers (US), 1994 Northridge (US), 1995 Kobe, 1999 Izmit (Turkey), 2001 El Salvador, 2003 Bam (Iran), 2004 Niigata (Japan), 2004 Indian Ocean, 2006 West of Iran and 2006 Java (Indonesia) earthquakes demonstrated the vulnerability of substation components to ground shaking. Failures commonly occurred in support structures of conductors, anchorage of power transformers, bushings, insulator poles, circuit breakers, and disconnect switches. Figures 1-4 show examples of damages to substation equipments in the 2004 Niigata Ken Chūetsu earthquake in Japan (JSCE/JGS, 2004). These damages occurred while mostly of power substations in Japan during last decades, especially after the Kobe 1995 earthquake,have been strengthened against earthquake. Japan Electric Association in 1985, for first time, developed a Guideline titled as “Earthquake resistant design guideline for electric facilities in power substation”, which was revised in 1999 (JEAG 5003-1999).Power substations based on functionality are classified in three types as follows:•Transmission substations (voltage and current increase or decrease)•Distribution substations (voltage decrease and current increase)•Switchyards (no change in voltage and current)Also based on voltage level they are categorized in three class, which are:•Low-voltage: less than 150 kV•Medium-voltage: between 150 kV and 350 kV•High-voltage: 350 kV and aboveIn this paper, seismic performance of medium- and high-voltage power substation equipments are discussed.Figure 1 Lightning arresters of all three- Figure 2 Oil leakage from joint betweenphases were broken in Nagaoka Sub. transformer and condenser in Minami Nagaoka Sub.(JSCE, 2004) (JSCE, 2004)Figure 3 Failure of condenser in Nagaoka sub. Figure 4 Extrusion of gasket and oil leakage(JSCE, 2004) in bushing of 154 kV transformer in Uonuma Sub.(JSCE, 2004)2. DATA GATHERINGIn this research, at first damages to the power systems in 43 earthquakes, from the 1923 Kanto earthquake(Japan) to the 2006 Java earthquake(Indonesia)are investigated, which hundreds of power substations had been suffered damage. Unfortunately exact information like as ground acceleration at substation site, description of damages, exact number of damaged equipments, voltage level of equipments and etc. in mostly of reports are not reported. Due to these data limitations, just enough data of 58 medium- and high-voltage substations (as the most vulnerable substations) are found, which are used in this paper. Due to volume consuming of this paper, it is not possible to list all specifications of these substations and also all references which are more than 80 references but it could be referred to Chapter 2 of (Bastami, 2007) to view list the mostly of the references. Operation of a power substation is function of equipments operation within the substation such as power transformer, disconnect switch, live-tank circuit breaker, current transformer, bus-bar and etc. A substation, based on its functionality, may include some or all the equipments. All important equipments within a standard substation are listed below:¾Power transformer¾Live-tank circuit breaker¾Dead-tank circuit breaker¾Disconnect switches¾Current transformer¾Potential transformer¾Bus-bar system¾Lightning arrester¾Wave trap¾Capacitive coupling voltage transformerIn this research all the above equipments are taken into account.3. PERFORMANCE OF SUBSTATION EQUIPMENTS IN PAST EARTHQUAKES3.1Performance of EquipmentsIn this section, results for seismic performance of the abovementioned equipments are presented. Percentage of damage for each equipment is defined as ratio of number of damaged equipments to total number of that equipment. Figures 5-14 depict percentage of damaged equipments in medium- and high-voltage substations respectively. The figures indicate vulnerability of all equipments within medium- or high-voltage power substations.Figure 5 Percentage of damaged power transformers in medium- and high-voltage substationsFigure 6 Percentage of damaged live-tank circuit breakers in medium- and high- voltage substationsFigure 7 Percentage of damaged dead-tank circuit breakers in medium- and high- voltage substationsFigure 8 Percentage of damaged disconnect switches in medium- and high- voltage substationsFigure 9 Percentage of damaged current transformers in medium- and high-voltage substationsFigure 10 Percentage of damaged potential transformers in medium- and high-voltage substationsFigure 11 Percentage of damaged bus-bar systems in medium- and high-voltage substationsFigure 12 Percentage of damaged lightning arresters in medium- and high-voltage substationsFigure 13 Percentage of damaged wave traps in medium- and high-voltage substationsFigure 14 Percentage of damaged capacitive coupling voltage transformer in medium- and high-voltagesubstationsTable 1 shows total number, number of the damaged and undamaged equipments, in which disconnect switches by 429 cases, live-tank circuit breakers by 150 cases and power transformers by 90 cases, bus-bar systems by 83 cases, lightning arresters by 81 cases and current transformers by 78 cases are damaged repeatedly in the 58 studied substations in past earthquakes. Table 1 also depicts percentage of damaged substation equipments, which indicates live-tank circuit breakers by 32.3% are the most vulnerable equipment and dead-tank circuit breakers by 2.5% have the best seismic performance. Current transformers, bus-bar systems, potential transformers and power transformers are the other vulnerable equipments. An interesting point is that disconnect switches by maximum reported number of damages, has better performance in comparison with live-tank circuit breakers, current transformers, bus-bar systems, potential transformers and power transformers.Table 1 Performance of the 58 medium- and high-voltage substation equipments in past earthquakesNo. Equipment TotalnumberDamagednumberUndamagednumberAverage ofpercentageof damage1 PowerTransformer 351 90 261 25.6% 2 Live-tankCircuitBreaker 464 150 314 32.3% 3 Dead-tankCircuitBreaker1133 28 1105 2.5% 4 DisconnectSwitch 3376 429 2947 12.7% 5 CurrentTransformer 250 78 172 31.2% 6 PotentialTransformer 89 23 66 25.8% 7 Bus-barSystem 261 83 178 31.8% 8 LightningArrester 540 81 459 15.0% 9 WaveTrap 114 27 87 23.7%10 Capacitive Coupling VoltageTransformer142 17 125 12.0%3.1Damage Ratio Curve of Medium and High Voltage SubstationsIn this section, a damage ratio curve for the medium and high voltage substations is proposed, which is shown in Figure 15. The curve is a bilinear curve, which is divided in two parts: first part is for PGA less than 0.55g and second part belongs to PGA more than 0.55g. For PGA equal to 0.55g, damage ratio is approximately estimated 0.28 and maximum damage ratio is approximately estimated 0.4 for PGA more than 1.1g.4. CONCLUSIONSThis paper seeks physical performance of power supply systems in past earthquakes. Damages to the power systems in 43 earthquakes, from the 1923 Kanto Earthquake until the 2006 Java Earthquake are studied. The selected earthquakes have proven widespread vulnerability of power system equipments from different points of view. Obtained results are summarized as follows:1- Damage to porcelain units of high- and medium-voltage substation equipment has been a recurring problem. Equipment operating at low voltages performs well when good seismic installation practices of anchorage and conductor interconnection flexibility are followed. Some types of equipment, which operating at voltages of 220 kV and above, are vulnerable. Generally, we can say: the higher operating voltage, the more vulnerable equipment.2- The highest voltage equipment, which is subjected to earthquake, is 500 kV.3- In medium and high-voltage substations, several types of failures are frequently observed. Inadequately anchored rail-supported transformers have fallen from their elevated platforms and have been severely damaged. Leaking or broken bushings are common.0.10.20.30.40.50.60.70.80.9100.10.20.30.40.50.60.70.80.91 1.1 1.2PGA(g)D a m a g e R a t i oFigure 15 Damage ratio curve of the medium and high voltage substations4- Design of some equipments appear to be inherently vulnerable, while other equipment that serves thesame function and operates at the same voltage can be quite rugged; for example, some live-tank circuit breakers versus dead-tank circuit breakers.5- Damage ratio curve of the medium and high voltage substations based on the 58 studied substationsis developed, which could be useful for engineers in practical purposes.ACKNOWLEDGMENTThe author wish to thank Professor Yasuko Kuwata from Kobe University for giving valuable data of the 2004Niigata Chuetsu Earthquake.REFERENCESBastami, Morteza (2007). Seismic Reliability of Power Supply System Based on Probabilistic Approach. Ph.D thesis, Kobe University, Japan.Japan Electric Association Guideline, (1999). Earthquake Resistant Design Guideline for Electric Facilities in Power Substation. JEAG 5003-1999, Japan, (in Japanese).JSCE/JGS mission on the 2004 Niigata Chuetsu earthquake (2004). Reconnaissance report on the 2004 Niigata Chuetsu Earthquake (ver1.0), Chapter 9.4 Power supply system (9pages) Available at http://shake.iis.u-tokyo.ac.jp/chuetsu/9-4.pdf (in Japanese).SEISMIC ASSESSMENT OF MEDIUM AND HIGH VOLTAGE POWER SUBSTATION EQUIPMENTS作者:Morteza Bastami作者单位:Assistant Professor, Dept. of Civil Engineering , University of Kurdistan, Sanandaj, Iran Assistant Professor, Dept. of Civil Engineering , Imam Khomeini International University,Ghazvin, Iran本文链接:/Conference_WFHYXW278686.aspx。
最新文件---------------- 仅供参考--------------------已改成-----------word文本 --------------------- 方便更改General Requirements to Construction of SubstationSubstations are a vital element in a power supply system of industrial enterprises.They serve to receive ,convert and distribute electric energy .Depending on power and purpose ,the substations are divided into central distribution substations for a voltage of 110-500kV;main step-down substations for110-220/6-10-35kV;deep entrance substations for 110-330/6-10Kv;distribution substations for 6-10Kv;shop transformer substations for 6-10/0.38-0.66kV.At the main step-down substations, the energy received from the power source is transformed from 110-220kV usually to 6-10kV(sometimes 35kV) which is distributed among substations of the enterprise and is fed to high-voltage services.Central distribution substations receive energy from power systems and distribute it (without or with partial transformation) via aerial and cable lines of deep entrances at a voltage of 110-220kV over the enterprise territory .Central distribution substation differs from the main distribution substation in a higher power and in that bulk of its power is at a voltage of 110-220kV;it features simplified switching circuits at primary voltage; it is fed from the power to an individual object or region .Low-and medium-power shop substations transform energy from 6-10kV to a secondary voltage of 380/220 or 660/380.Step-up transformer substations are used at power plants for transformation of energy produced by the generators to a higher voltage which decreases losses at a long-distance transmission .Converter substations are intended to convert AC to DC (sometimes vice versa) and to convert energy of one frequency to another .Converter substations with semiconductor rectifiers are convert energy of one frequency to another .Converter substations with semiconductor rectifiers are most economic. Distribution substations for 6-10kV are fed primarily from main distribution substations (sometimes from central distribution substations).With a system of dividing substations for 110-220kV, the functions of a switch-gear are accomplished by switch-gears for 6-10kV at deep entrance substations.Depending on location of substations their switch-gear may be outdoor or indoor. The feed and output lines at 6-10kV substations are mainly of the cable type .at 35-220kV substations of the aerial type .When erecting and wiring the substations ,major attention is given to reliable and economic power supply of a given production.Substations are erected by industrial methods with the use of large blocks and assemblies prepared at the site shops of electric engineering organizations and factories of electrical engineering industry .Substations are usually designed for operation without continuous attendance of the duty personnel but with the use of elementary automatic and signaling devices.When constructing the structural part of a substation .it is advisable to use light-weight industrial structures and elements (panels ,floors ,etc.) made of bent sections .These elements are pre-made outside the erection zone and are only assembled at site .This considerably cuts the terms and cost of construction.Basic circuitry concepts of substations are chosen when designing a powersupply system of the enterprise .Substations feature primary voltage entrances .transformers and output cable lines or current conductors of secondary voltage .Substations are mounted from equipment and elements described below .The number of possible combinations of equipment and elements is very great .Whenelaborating a substation circuitry ,it is necessary to strive for maximum simplification and minimizing the number of switching devices .Such substations are more reliable and economic .Circuitry is simplified by using automatic reclosure or automatic change over to reserve facility which allows rapid and faultless redundancy of individual elements and using equipment.When designing transformer substations of industrial enterprises for all voltages , the following basic considerations are taken into account:1. Preferable employment of a single-bus system with using two-bus systems only to ensure a reliable and economic power supply;2. Wide use of unitized constructions and busless substations;3.Substantiated employment of automatics and telemetry ;if the substation design does not envisage the use of automatics or telemetry ,the circuitry is soarranged as to allow for adding such equipment in future without excessive investments and re-work.e of simple and cheap devices-isolating switches ,short-circuiting switches ,load-breaking isolators ,fuses ,with due regard for their switching capacity may drastically cut the need for expensive and critical oil ,vacuum ,solenoid and air switches .Substation and switch-gear circuitries are so made that using the equipment of each production line is fed from individual transformers ,assemblies ,the lines to allow their disconnection simultaneously with mechanisms without disrupting operation of adjacent production flows.When elaborating circuitry of a substation, the most vital task is to properly choose and arrange switching devices(switches ,isolators ,current limiters ,arresters ,high-voltage fuses).The decision depends on the purpose ,power and significance of the substation.Many years ago, scientists had very vague ideas about electricity. Many of them thought of it as a sort of fluid that flowed through wires as water flows through pipes, but they could not understand what made it flow. Many of them felt that electricity was made up of tiny particles of some kind ,but trying to separate electricity into individual particles baffled them.Then, the great American scientist Millikan, in 1909,astounded the scientific world by actually weighing a single particle of electricity and calculating its electric charge. This was probably one of the most delicate weighing jobs ever done by man,for a single electric particle weighs only about half of a millionth of a pound. To make up a pound it would take more of those particles than there are drops of water in the Atlantic Ocean.They are no strangers to us, these electric particles, for we know them as electrons. When large numbers of electrons break away from their atoms and move through a wire,we describe this action by saying that electricity is flowing through the wire.Yes,the electrical fluid that early scientists talked about is nothing more than electrical flowing along a wire.But how can individual electrons be made to break away from atoms? And how can these free electrons be made to along a wire? The answer to the first questionlies in the structure of the atoms themselves. Some atoms are so constructed that they lose electrons easily. An atom of copper, for example ,is continually losing an electron, regaining it(or another electron),and losing it again. A copper atom normally has 29 electrons, arranged in four different orbits about its nucleus. The inside orbit has 2 electrons. The next larger orbit has 8.The third orbit is packed with 18 electrons . And the outside orbit has only one electron.It is this outside electron that the copper atom is continually losing, for it is not very closely tied to the atom. It wanders off, is replaced by another free-roving electron, and then this second electron also wanders away.Consequently,in a copper wire free electrons are floating around in all directions among the copper atoms.Thus, even through the copper wire looks quite motionless to your ordinary eye, there is a great deal of activity going on inside it. If the wire were carrying electricity to an electric light or to some other electrical device, the electrons would not be moving around at random. Instead, many of them would be rushing in the same direction-from one end of the wire to the other.This brings us to the second question .How can free electrons be made to move along a wire? Well ,men have found several ways to do that .One way is chemical. Volta,s voltaic pile,or battery, is a chemical device that makes electricity(or electrons)flow in wires. Another way is magnetic. Faraday and Henry discovered how magnets could be used to make electricity flow in a wire.MagnetsAlmost everyone has seen horseshoe magnets-so called because they are shaped like horseshoes. Probably you have experimented with a magnet, and noticed how it will pick up tacks and nails, or other small iron objects. Men have known about magnets for thousands of years.Several thousand years ago, according to legend, a shepherd named Magnes lived on the island of Crete, in the Mediterranean Sea .He had a shepherds crook tipped with iron. One day he found an oddly shaped black stone that stuck to this iron ter, when many other such stones were found, they were called magnets(after Magnets).These were natural magnets.In recent times men have learned how to make magnets out of iron. Moreimportant still, they have discovered how to use magnets to push electrons through wires-that is, how to make electricity flow. Before we discuss this, there arecertain characteristics of magnets that we should know about.If a piece of glass is laid on top of a horse- shoes magnet, and if iron filings are then sprink ledon the glass, the filings will arrange themselves into lines. If this same thing is trid with a bar magnet(a horseshoe magnet straightened out),the lines can be seen more easily. These experiments demonstrate what scientists call magnetic lines of force. Magnets, they explain, work through lines of force that ext- end between the two ends of the magnet. But electrons seem to have magnetic lines of force around them, too.This can be proved by sticking a wire through a piece ofcard board, sprinkling iron filings on the cardboard, and connecting a battery to the wire. The filings will tend to form rings around the wire,as a result of the magnetism of the moving electrons(or electricity).So we can see that there is arelationship between moving electrons and magnetism, Magnetism results from the movement of electrons.Of course, electrons are not really flowing in the bar magnet, but they are in motion, circling the nuclei of the iron atoms. However, in the magnet, circling thelined up in such a way that their electrons are circling in the same direction. Perhaps a good comparison might be a great number of boys whirling balls onstrings in a clockwise direction around their heads.——The Trend Of Integrated Substation Automation Technology Development最新文件---------------- 仅供参考--------------------已改成-----------word文本 --------------------- 方便更改赠人玫瑰,手留余香。
变电站设计英文参考文献以下是关于变电站设计的英文参考文献列表及简介:1. "Modern Power Station Practice Vol 1: Electrical Systems and Equipment" by Central Electricity Generating Board (CEGB) - 这本书是关于电站设计的权威参考书之一,其中包含了变电站设计的细节和要求。
2. "HVDC Transmission: Power Conversion Applications in Power Systems" by K.R. Padiyar - 这本书主要涉及高压直流输电的理论和应用,而变电站通常是将交流电转换成直流电进行输电的一部分,因此这本书可以帮助设计师更好地理解变电站的工作原理。
3. "Electric Power Substations Engineering" by John D. McDonald- 这本书是变电站设计和工程的综合指南,包含了变电站的各个方面,从概述到详细设计,以及施工和运行。
4. "Transformer and Inductor Design Handbook" by Colonel Wm. T. McLyman - 压变和电感器是变电站中常见的元件,因此设计师需要了解它们的设计和制造,这本书提供了详细的指导和案例。
5. "Electric Power Distribution Handbook" by Thomas Allen Short- 这本书提供了关于配电系统的基础知识和设计方法,这对于变电站设计师来说也非常重要,因为变电站通常是配电网络的一个关键组成部分。
6. "Switchgear and Protection" by J.B Gupta - 变电站中使用的开关设备和保护系统非常关键,这本书提供了涵盖相关主题的详细信息,包括故障和过电压保护,以及开关设备的选择和维护。
变电站设计英文参考文献# Design of SubstationSubstations play a vital role in the power system infrastructure, serving as the main junction point for the transmission and distribution of electrical energy. The design of substations requires careful consideration of various factors to ensure safe and efficient power transfer. This article provides an overview of the design considerations involved in the planning and construction of a substation.## Site SelectionThe first step in substation design is to identify an appropriate location. The site must be strategically chosen, considering factors such as proximity to power sources, accessibility, land availability, and environmental impacts. Adequate land area is required to accommodate the equipment, structures, and necessary safety clearances.## Electrical System AnalysisOnce the site is finalized, an electrical system analysis is conducted to determine the voltage level, load capacity, and other electrical parameters. This analysis helps in determining the type and rating of transformers, circuit breakers, and other equipment required for the substation.## Substation LayoutThe layout of the substation depends on several factors, including the configuration of the electrical system and available land area. The layout should be designed to allow for efficient power flow, adequate spacing between equipment, and clear access for maintenance and operation. Different areas for high voltage, medium voltage, and low voltage equipment are designated within the substation.## Equipment SelectionCareful selection of equipment is crucial for a well-functioning substation. Transformers, circuit breakers, switchgear, protection relays, and control systems are some of the essential components. The equipment should be reliable, efficient, and compatible with the electrical system requirements. Factors such as load capacity, fault current ratings, and safety features are considered during equipment selection.## Safety ConsiderationsSafety is of utmost importance in substation design. Adequate safety measures should be implemented to protect personnel and equipment. Safety clearances, grounding systems, fire suppression systems, and protective barriers are some of the key considerations. Compliance with relevant codes, standards, and regulations is essential for ensuring a safe working environment.## Environmental ImpactThe environmental impact of a substation should be minimized. Measures such as proper disposal of waste materials, noise reduction, and landscaping are undertaken to mitigate the impact on the surrounding ecosystem and nearby communities. Environmental regulations and guidelines must be followed throughout the design and construction process.## Construction and CommissioningOnce the design is finalized, the construction phase begins. The construction process involves civil works, installation of equipment, wiring, and testing. The commissioning phase includes the initial energization, functional testing, and synchronization with the power grid. Proper coordination between various stakeholders, including engineers, contractors, and utility companies, is crucial for a successful construction and commissioning process.## Maintenance and UpgradesRegular maintenance and upgrades are essential for the efficient operation of a substation throughout its lifespan. Periodic inspections, equipment testing, and preventivemaintenance help ensure the reliability and safety of the substation. Upgrades may be required to accommodate future growth, technological advancements, or changes in the electrical system.In conclusion, the design of a substation involves several critical considerations, including site selection, electrical system analysis, layout design, equipment selection, safety measures, environmental impact, and construction and commissioning processes.A well-designed and properly maintained substation is vital for the reliable and uninterrupted transmission and distribution of electrical energy.。
On architectural design of electrical energy saving methods Abstract : In this paper the architectural design of electrical energy saving, energy—saving methods, from the choice of transformer capacity, power factor compensation, lighting dimmers equipment, motor starter equipment selection, Electrical Design exposition of several energy—saving methods.Keywords : loss of electrical energy saving transformer power factor VVVF lighting energy saving soft starter ,as a result of population increase , industrial development, the improvement of living standards, the consumption of energy has increased dramatically, the energy crisis was imminent.Therefore, the businesses of the energy—saving requirements, secondary energy conservation -- Energy, civil construction, it has become the focus of electrical design。
POWER SYSTEM RELAYING1、What is relaying?In order to understand the function of protective relaying systems, one must be familiar with the nature and the modes of operation of an electric power system. Electric energy is one of the fundamental resources of modem industrial society. Electric power is available to the user instantly, at the correct voltage and frequency, and exactly in the amount that is needed. This remarkable performance is achieved through careful planning, design, installation and operation of a very complex network of generators, transformers, and transmission and distribution lines. To the user of electricity, the power system appears to be in a steady state: imperturbable, constant and infinite in capacity. Yet, the power system is subject to constant disturbances created by random load changes, by faults created by natural causes and sometimes as a result of equipment or operator failure. In spite of these constant perturbations, the power system maintains its quasi steady state because of two basic factors: the large size of the power system in relation to the size of individual loads or generators, and correct and quick remedial action taken by the protective relaying equipment.Relaying is the branch of electric power engineering concerned with the principles of design and operation of equipment (called “relays’or ‘protective relays’)that detects abnormal power system conditions, and initiates corrective action as quickly as possible in order to return the power system to its normal state. The quickness of response is an essential element of protective relaying systems - response times of the order of a few milliseconds are often required. Consequently,human intervention in the protection system operation is not possible. The response must be automatic, quick and should cause a minimum amount of disruption to the power system. To accomplish these goals, we must examine all possible types of fault or abnormal conditions which may occur in the power system. We must analyze the required response to each of these events, and design protective equipment which will provide such a response. We must further examine the possibility that protective relaying equipment itself may fail to operate correctly, and provide for a backup protective function. It should be clear that extensive and sophisticated equipment is needed to accomplish these tasks.2、Power system structural considerations 2.1Multilayered structure of power systemsA power system is made up of interconnected equipment which can be said to belong to one of three layers from the point of view of the functions performed. At the basic level is the power apparatus which generates, transforms and distributes the electric power to the loads. Next, there is the layer of control equipment. This equipment helps maintain the power system at its normal voltage and frequency, generates sufficient power to meet the load and maintains optimum economy and security in the interconnected network. The control equipment is organized in a hierarchy of its own, consisting of localand central control functions. Finally, there is the protection equipment layer. The response time of protection functions is generally faster than that of the control functions. Protection acts to open and close circuit breakers, thus changing the structure of the power system, whereas the control functions act continuously to adjust system variables, such as the voltages, currents and power flow on the network. Oftentimes, the distinction between a control function and a protection function becomes blurred. This is becoming even more of a problem with the recent advent of computer-based protection systems in substations. For our purposes, we may arbitrarily define all functions which lead to operation of power switches or circuit breakers to be the tasks of protective relays, while all actions which change the operating state (voltages, currents, power flows) of the power system without changing its structure to be the domain of control functions.2.2 Neutral grounding of power systemsNeutrals of power transformers and generators can be grounded in a variety of ways, depending upon the needs of the affected portion of the power system. As grounding practices affect fault current levels, they have a direct bearing upon relay system designs. In this section, we will examine the types of grounding system in use in modem power systems and the reasons for each of the grounding choices.It is obvious that there is no ground fault current in a truly ungrounded system. This is the main reason for operating the power system ungrounded. As the vast majority of faults on a power system are ground faults, sendee interruptions due to faults on an ungrounded system are greatly reduced. However, as the number of transmission lines connected to the power system grows, the capacitive coupling of the feeder conductors with ground provides a path to ground, and a ground fault on such a system produces a capacitive fault current. This is illustrated in Figure 1 (a). The coupling capacitors to ground CO provide the return path for the fault current. The interphase capacitors 1/3 Cl play no role in this fault. When the size of thecapacitance becomes sufficiently large, the capacitive ground fault current becomes self-sustaining, and docs not clear by itself. It then becomes necessary to open the circuit breakers to clear the fault, and the relaying problem becomes one of detecting such low magnitudes of fault currents. In order to produce a sufficient fault current, a resistance is introduced between the neutral and the ground - inside the box shown by a dotted line in Figure 1 (a). One of the design considerations in selecting the grounding resistance is the thermal capacity of the resistance to handle a sustained ground fault.Ungrounded systems produce good service continuity, but are subjected to high oven^oltages on the unfaulted phases when a ground fault occurs. It is clear from the phasor diagram of Figure 1 (b) that when a ground fault occurs on phase a,the steady-state voltages of phases b and c become^ 3 times their normal value. Transient overvoltages become correspondingly higher. This places additional stress on theinsulation of all connected equipment. As the insulation level of lower voltage systems is primarily influenced by lightning-induced phenomena, it is possible to accept the fault-induced overvoltages as they are lower than the lightning-induced overvoltages. However,as the system voltages increase to higher than about 100 kV, the fault-induced overvoltages begin to assume a critical role in insulation design, especially of power transformers. At high voltages, it is therefore common to use solidly grounded neutrals (more precisely 'effectively grounded^). Such systems have high ground fault currents, and each ground fault must be cleared by circuit breakers.As high-voltage systems are generally heavily interconnected, with several alternative paths to load centers, operation of circuit breakers for ground faults does not lead to a reduced service continuity.In certain heavily meshed systems, particularly at 69 kV and 138 kV the ground fault current could become excessive because of very low zero sequence impedance at some buses. If ground fault current is beyond the capability of the circuit breakers, it becomes necessary to insert an inductance in the neutral in order to limit the ground fault current to a safe value. As the network Thevenin impedance is primarily inductive, a neutral inductance is much more effective (than resistance) in reducing the fault current. Also, there is no significant power loss in the neutral reactor during ground faults.In several lower voltage networks, a very effective alternative to ungrounded operation can be found if the capacitive fault current causes ground faults to beC〇 C〇 C〇(a)self-sustaining. This is the use of a Petersen coil, also known as the ground fault neutralizer (GFN). Consider the symmetrical component representation of a ground fault on a power system,which is grounded through a grounding reactance of ^(Figure 2). If 3办 is made equal to XcO (the zero sequence capacitive reactance of the connected network), the parallel resonant circuit formed by these two elements creates an open circuit in the fault path, and the ground fault current is once again zero. The overvoltages produced on the unfaulted conductors are comparable to those of ungrounded systems, and consequently GFN use is limited to system voltages below 100 kV. In practice, GFNs must be tuned to the entire connected zero sequence capacitance on the network, and thus if some lines are out of service,the GFNreactance must be adjusted accordingly. Petersen coils have found much greater use in several European countries than in the USA.Figure 1 Neutral grounding impedance, (a) System diagram, (b) Phasor diagram showing neutralshift on ground faultFigure 2 Symmetrical component representation for ground fault with grounding reactor3、P o w e r system bus configurationsThe manner in which the power apparatus is connected together in substations and switching stations, and the general layout of the power network, has a profound influence on protective relaying. It is therefore necessary to review the alternatives,From Transmission NetworkSwitch Main TransformerLoadand the underlying reasons for selecting a particular configuration. A radial system is a single-source arrangement with multiple loads, and is generally associated with a distribution system (defined as asystem operating at voltages below 100 kV) or an industrial complex (Figure 3).SwitchSwitch Load LoadFigure 3 Radial power system Such a system is most economical to build; but from the reliability point of view, the loss of the single source will result in the loss of service to all of the users. Opening main line reclosers or other sectionalizing devices for faults on the line sections will disconnect the loads downstream of the switching device. From the protection point of view, a radial system presents a less complex problem. The fault current can only flow in one direction, i.c. away from the source and towards the fault. Since radial systems are generally electrically remote from generators, the fault current docs not vary much with changes in generation capacity.A network has multiple sources and multiple loops between the sources and the loads. Subtransmission and transmission systems (generally defined as systems operating at voltages of 100-200 kV and above) arc network systems (Figure 4).In a network, the number of lines and their interconnections provide more flexibility in maintaining service to customers, and the impact of the loss of a single generator or transmission line on service reliability is minimal. Since sources of power exist on all sides of a fault, fault current contributions from each direction must be considered in designing the protection system. In addition, the magnitude of thefault current varies greatly with changes in system configuration and installed generation capacity.4、The nature of relayingWe will now discuss certain attributes of relays which are inherent to the process of relaying, and can be discussed without reference to a particular relay. The function of protective relaying is to promptly remove from sendee any element of the power system that starts to operate in an abnormal manner. In general, relays do not prevent damage to equipment: they operate after some detectable damage has already occurred. Their purpose is to limit, to the extent possible, further damage to equipment, to minimize danger to people, to reduce stress on other equipment and, above all, to remove the faulted equipment from the power system as quickly as possible so that the integrity and stability of the remaining system is maintained. The control aspect of relaying systems also helps return the power system to an acceptable configuration as soon as possible so that sendee to customers can be restored.。
附录Ⅲ英文翻译A comprehensive overview of substationsAlong with the economic development and the modern industry developments ofquick rising, the design of the power supply system become more and more completelyand system. Because the quickly increase electricity of factories, it also increases seriously to the dependable index of the economic condition, power supply in quantity. Therefore they need the higher and more perfect request to the power supply. Whether Design reasonable, not only affect directly the base investment and circulate the expenses with have the metal depletion in colour metal, but also will reflect the dependable in power supply and the safe in many facts. In a word, it is close with the economic performance and the safety of the people. The substation is an importancepart of the electric power system, it is consisted of the electric appliances equipmentsand the Transmission and the Distribution. It obtains the electric power from theelectric power system, through its function of transformation and assign, transport and safety. Then transport the power to every place with safe, dependable, and economical.As an important part of power’s transport and control, the transformer substation must change the mode of the traditional design and control, then can adapt to the modernelectric power system, the development of modern industry and the of trend of thesociety life.Electric power industry is one of the foundations of national industry andnational economic development to industry, it is a coal, oil, natural gas, hydropower,nuclear power, wind power and other energy conversion into electrical energy of the secondary energy industry, it for the other departments of the national economy fastand stable development of the provision of adequate power, and its level of development is a reflection of the country's economic development an important indicator of the level. As the power in the industry and the importance of the national economy, electricity transmission and distribution of electric energy used in these areasis an indispensable component.。
变电站-外文翻译-外文文献-英文文献-变电站的综合概述英文翻译A comprehensive overview of substationsAlong with the economic development and the modern industry developments of quick rising, the design of the power supply system become more and more completely and system. Because the quickly increase electricity of factories, it also increases seriously to the dependable index of the economic condition, power supply in quantity. Therefore they need the higher and more perfect request to the power supply. Whether Design reasonable, not only affect directly the base investment and circulate the expenses with have the metal depletion in colour metal, but also will reflect the dependable in power supply and the safe in many facts. In a word, it is close with the economic performance and the safety of the people. The substation is an importance part of the electric power system, it is consisted of the electric appliances equipments and the Transmission and the Distribution. It obtains the electric power from the electric power system, through its function of transformation and assign, transport and safety. Then transport the power to every place with safe, dependable, and economical. As an important part of power’s transport and control, the transformer substation must change the mode of the traditional design and control, then can adapt to the modern electric power system, the development of modern industry and the of trend of the society life.Electric power industry is one of the foundations of national industry and national economic development to industry, it is a coal, oil, natural gas, hydropower, nuclear power, wind power and other energy conversion into electrical energy of the secondary energy industry, it for the other departments of the national economy fast and stable development of the provision of adequate power, and its level of development is a reflection of the country's economic development an important indicator of the level. As the power in the industry and the importance of the national economy, electricity transmission and distribution of electric energy used in these areas is an indispensable component.。
变电站综合自动化简介变电站综合自动化是指通过计算机技术和自动化控制技术,对变电站的各个环节进行集成、控制和管理的一种技术手段。
通过变电站综合自动化,可以实现对变电站的设备、数据和运行状态进行实时监测、控制和管理,提高变电站的运行效率和可靠性。
变电站综合自动化的核心技术SCADA系统SCADA系统〔Supervisory Control And Data Acquisition〕是变电站综合自动化的核心技术之一。
该系统通过采集变电站的设备数据,将数据传输到中央控制中心,并实时显示设备状态。
同时,SCADA系统还可以通过控制命令实现对变电站设备的远程控制。
通过SCADA系统,运维人员可以及时监控变电站的运行状态,及时发现并解决问题,提高变电站的稳定性和可靠性。
分布式控制系统分布式控制系统〔Distributed Control System〕是变电站综合自动化的另一个核心技术。
该系统通过将变电站的控制功能分散到多个子系统中,实现对整个变电站的分布式控制。
通过分布式控制系统,可以实现对变电站设备的监测、控制和调度。
同时,分布式控制系统还可以根据变电站的运行状况进行自动调节和优化,提高变电站的运行效率和可靠性。
通信技术通信技术在变电站综合自动化中起着重要的作用。
通过通信技术,可以实现变电站设备之间的数据交换和控制命令传递。
常用的通信技术包括以太网、无线通信、工业总线等。
通过合理选择通信技术,可以确保变电站各个设备之间的稳定和可靠的通信连接,从而实现变电站的集成控制。
变电站综合自动化的应用变电站设备监控变电站综合自动化可以实现对变电站各个设备状态的实时监测。
通过传感器采集设备的运行数据,SCADA系统可以及时显示设备的状态和参数。
当设备出现异常或故障时,系统会及时报警,并通过分布式控制系统对设备进行相应的控制。
这样可以及时发现问题并采取措施,从而提高设备的可靠性和平安性。
变电站运行调度变电站综合自动化可以实现对变电站的运行调度。
变电站外文翻译外文文献英文文献变电站的综合概述Introduction:2. Circuit Breakers: Circuit breakers are protective devices used to interrupt or break an electrical circuit during abnormal conditions. They prevent excessive damage to equipment and maintain system stability by isolating faulty parts from therest of the system.3. Switchgear: Switchgear refers to a collection ofelectrical disconnect switches, fuses, or circuit breakers used to control and protect electrical equipment within the substation. It allows operators to isolate faulty sections of the electrical network for maintenance or repair without affecting the rest of the system.5. Lightning Arresters: Lightning arresters are protective devices installed on substation equipment to safeguard against high voltage surges caused by lightning strikes. They divert the excess electrical energy away from the equipment and prevent damage to the substation.Types of Substations:2. Transmission Substations: Transmission substations receive electricity from power generating stations and transform the voltage to a suitable level for long-distance transmissionover high voltage transmission lines. They are often located at the interconnection points between different transmission lines.3. Switching Substations: Switching substations provide switching, control, and protection functions in the electrical power system. They allow for the rerouting of power flows and enable system operators to isolate faulty equipment or sectionsof the system while still maintaining power supply to consumers.4. Converter Substations: Converter substations are specific to systems using high voltage direct current (HVDC) transmission technology. They convert alternating current (AC) from the power grid to direct current (DC) for transmission over long distances, and then convert it back to AC at the receiving end.Conclusion:。
变电站中英文资料对照外文翻译文献综述XXXns are an essential part of electrical power systems。
servingas the interface een high-voltage n lines and lower-voltage n lines。
They play a critical role in XXX homes。
businesses。
and industries.Types of nsThere are several types of ns。
including n ns。
n ns。
and customer XXX to the end-users and step down the voltage for n to XXX a single customer or group of customers.XXXns consist of us components。
including transformers。
circuit breakers。
switches。
XXX are used to step up or step down thevoltage of the electricity。
XXX are used to control the flow ofXXX to the system.XXXXXX stages。
including site n。
layout design。
equipment n。
XXX n lines。
land availability。
and environmental ns。
The layout design involves determining the placement of equipment。
XXX appropriate transformers。
circuit breakers。
and other components。
综合自动化系统在变电站中应用与分析李少飞(大庆石油学院,黑龙江大庆163453)摘 要:阐述了220k V 黑河一次变电所综合自动化系统RCS -9000的计算机监控、管理和控制,商用数据库和标准S QL 接口,分布式多网络结构及特点,多媒体人机界面,系统开放实现方式。
指出了该自动化系统需要改进的要点。
关键词:变电站;自动化系统;接口;监控系统中图分类号:T M76 文献标识码:A 文章编号:1002-1663(2007)05-0368-04Ana lysis and a ppli ca ti on of com pr ehen si ve a uto ma ti csystem to subst a ti onL I Shaofei(Daqing Pe troleu m Institue,Daqing 163453,China )Abstrac t:The paper discussed the comp rehensive aut om atic system RCS -9000of Heihe 220kV pri ma r y sub 2station in computer monit oring,manage m ent and contr olling,comm erce data and standard S Q L interf ace,dis 2tributing multi -net wor k structure and its cha r acteristic s,m ultiple m edia interface of operat or to computer and the mode of i mple m ent syste m open .And key points that m ust be i mp r oved t o the syste m was p r oposed.Key wor ds:substati on;automa tic syste m ;interf ace;monit oring syste m. 随着数字式微机保护、监控技术和远动通信技术的发展,电力系统变电站的自动化水平发生了根本性变革。
110kv Substation Primary Design English References1. C. Sankarakrishnan, G. Subramanian, and S. S. Brahmanandam, “Design and development of a 110 kV substation SCADA system using IEC xxx-5-104 protocol,” in 2018 International Conference on Power, Instrumentation, Control and Computing (PICC), Kannur, India, 2018, pp. 1-6.2. A. J. Morozov, “Selection of optimal design solutions for 110 kV substation switchgear,” Bulletin of the Tomsk Polytechnic University, vol. 326, no. 1, pp. 6-11, 2018.3. F. Khan, M. Amjad, and M. Saleem, “Analysis and design of 110 kV gas insulated substation (GIS) and itsparative analysis with 本人r insulated substation (本人S),” in 2019 International Conference on Sust本人nable Energies, Power and Computing (SEPC), Bangalore, India, 2019, pp. 1-6.4. M. M. Qinawy, A. M. Mansour, and R. A. Mahmoud, “Optimization of 110 kV substation grounding grid using genetic algorithm,” Electric Power Systems Research, vol. 148, pp. 40-47, 2017.5. Y. Ueda, K. Taniguchi, and H. Fujii, “Design and economic analysis of a 110/20 kV substation with a battery energy storage system for peak load shaving,” in 2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe), Turin, Italy, 2017, pp. 1-6.6. Z. Wang and F. Cao, “Research on applications of IECxxx in 110kV substation digital control systems,” in 2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia), Kaohsiung, T本人wan, 2017, pp. 188-191.7. Q. Zeng, S. Zhao and Y. Zhou, “Si mulating and analyzing the insulation co-ordination for a 110 kV substation,” in 2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia), Kaohsiung, T本人wan, 2017, pp. 1512-1516.8. B. M. Trinh and T. H. Phan, “A study on design of a 110/22 kV substation grounding grid,” in 2019 7th International Conference on the Development of Renewable Energy Technology (ICDRET), Hanoi, Vietnam, 2019, pp. 1-6.9. Y. Cheng, H. Li, and Z. Lu, “Design and simulation of a 110 kV substation surge arrester based on PSCAD/EMTDC,” in 2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe), Turin, Italy, 2017, pp. 1-5.10. R. Pik and D. Mastelic, “Design and implementation of a 110/35 kV substation automation system based on IEC xxx standard,” in 2018 International Symposium ELMAR, Zadar, Croatia, 2018, pp. 277-282.。
变电站综合自动化系统分析摘要近年来,作为计算机和数字通信技术,二次变电站设备基本上是基于计算机的。
电脑保护,电脑在变电站的监控设备已被广泛应用,这大大提高了电力系统运行的自动化水平和可靠性,已经实现了许多无人值守变电站。
但是,由于专业水平的差异,不同制造商所采用的变电站自动化设计程序不一样,因此给广大用户带来了亏损。
变电站继电保护,故障记录仪,本地和远程监控不仅有不同的功能,而且各项原则和技术的实现也不同。
因此,需要在不同的技术上和相应的管理部门长期累积专业技能。
随着微机保护,计算机控制和远程计算机设备如此广泛应用,有人指出尽管这些设备的功能不同,但硬件配置是一样的,收集和控制许多相同的对象。
因此,考虑变电站自动化的思路要从全局出发。
然而,在变电站自动化技术中,继电器,测量,控制,远程执行过程中的特征以及它们之间的关系,还存在一些问题值得我们学习。
关键词:变电站自动化下面目前用于许多国内变电站自动化设计实际过程中,从辅助系统分析和几个方面比较考虑。
1. 系统结构整个系统层由站管理,工业总线网络层和间隔层三部分组成,系统的所有监控,保护设备在设计结构上采用模块化单位,根据变电站电压水平和用户需要,大小可灵活变动。
因为中央系统不再使用,它不在这里,下面只介绍分布式系统的结构。
1.1 面向功能的分布式系统每个单元完成一个功能,系统的功能可分为:交流和直流测量单元,远程采集单元,远程控制和运行单元,脉冲能量收集单元,如保护单元。
这种系统的优点是功能单元的通信总线处于完全隔离的电气之间,系统单元的故障对系统的其它部分没有影响。
缺点是多屏组,第二布线比较复杂,可扩性差,分散单元无法安装。
1.2 面向区间的分布式系统进入到变电站的输电线路分为许多区间,如行距,变压器间距,全局布置。
相对独立的空间设备,仅通过互联网通信网络站与站级计算机通信。
区间的每一层有遥测,遥控,远程控制,分布式多CPU 保护装置,电脑在局域网技术设计的引入,分布式功能,尽可能权力下放的原则,虽然大大改善了可靠性,任何区间的失败不会影响其它分区,但每个区间的可靠性比较低,如果任何一个区间有故障将影响整个区间。
英文翻译A comprehensive overview of substationsAlong with the economic development and the modern industry developments of quick rising, the design of the power supply system become more and more completely and system. Because the quickly increase electricity of factories, it also increases seriously to the dependable index of the economic condition, power supply in quantity. Therefore they need the higher and more perfect request to the power supply. Whether Design reasonable, not only affect directly the base investment and circulate the expenses with have the metal depletion in colour metal, but also will reflect the dependable in power supply and the safe in many facts. In a word, it is close with the economic performance and the safety of the people. The substation is an importance part of the electric power system, it is consisted of the electric appliances equipments and the Transmission and the Distribution. It obtains the electric power from the electric power system, through its function of transformation and assign, transport and safety. Then transport the power to every place with safe, dependable, and economical. As an important part of power’s transport and control, the transformer substation must change the mode of the traditional design and control, then can adapt to the modern electric power system, the development of modern industry and the of trend of the society life.Electric power industry is one of the foundations of national industry and national economic development to industry, it is a coal, oil, natural gas, hydropower, nuclear power, wind power and other energy conversion into electrical energy of the secondary energy industry, it for the other departments of the national economy fast and stable development of the provision of adequate power, and its level of development is a reflection of the country's economic development an important indicator of the level. As the power in the industry and the importance of the national economy, electricity transmission and distribution of electric energy used in these areas is an indispensable component.。