KC23B10.002NLF;中文规格书,Datasheet资料
- 格式:pdf
- 大小:98.85 KB
- 文档页数:2
SD387EVKLMH0387 Evaluation Board User Guide National Semiconductor EVK User ManualApril 29, 2010OverviewThe SD387 Evaluation Kit (EVK) enables evaluation of the LMH0387 3G/HD/SD SDI Configurable I/O Adaptive Cable Equalizer / Cable Driver. A graphical user interface allows managing the SPI registers for the input mode (equalizer), and can also be used to control the device’s I/O mode.Evaluation Kit (SD387EVK) ContentsThe EVK contains the following parts:•SD387EVK board assembly with the LMH0387 configurable I/O•SPA dongle (SPIÆUSB card)• USB cable•6-pin parallel cable• SD387EVK User GuideEvaluation Board DescriptionFigure 1 shows the SD387 evaluation board and highlights some of its features.FIGURE 1. SD387 Evaluation BoardInputs and Outputs: BNC_IO Input/Output, SDI Input, and SDO OutputThe bidirectional I/O (J1) is a 75Ω BNC connector. When the LMH0387 is configured as an input, the input signal on the BNC_IO pin should conform to the SMPTE 424M, SMPTE 292M, or SMPTE 259M standards. When the LMH0387 is configured as an output, the BNC_IO pin will drive SMPTE SDI signal levels (800 mV P-P into 75Ω).The SDI input connectors (J2 and J3) are 50Ω SMA connectors. This cable driver input includes a 100Ω differential termination resistor (R5) at the LMH0387 device and is optimized for 100Ω differential input.The SDO output connectors (J4 and J5) are 50Ω SMA connectors. When using only one side of this equalizer output pair, the other side should be terminated with a 50Ω SMA termination. For example, when only using theSDO output, SDO¯¯¯¯ should be terminated with a 50Ω SMA termination.DC Power ConnectorsThe VCC and GND power connectors should be powered with a DC input voltage of 3.3V ± 5% (3.6V maximum).JP2 ControlsCD ¯¯¯JP2 allows monitoring of the Carrier Detect (CD¯¯¯ ) at the BNC_IO pin while in the input mode (equalizer). CD ¯¯¯ is asserted low when an input signal is detected at the BNC_IO pin, and high when no input signal is present. TX_ENJP2 allows control of the TX_EN pin to enable or disable the cable driver. The LMH0387 TX_EN pin has aninternal pullup to enable the cable driver by default, so this pin may be left unconnected when using the LMH0387 in the output mode. To disable the cable driver, place a jumper to tie TX_EN to GND. When using the LMH0387 in the input mode, the cable driver must be disabled by tying TX_EN low. TX_EN may optionally be controlled via the GUI using the SPA dongle as described below. SD/HD¯¯¯ JP2 allows control of the SD/HD¯¯¯ pin for setting the slew rate for the BNC_IO pin while the LMH0387 is in the output mode (cable driver). This pin may be connected to GND for the faster HD/3G slew rate or connected to V CC for theslower SD slew rate. The LMH0387 SD/HD¯¯¯ pin has an internal pulldown to enable the HD/3G slew rate by default.SPI Header (JP1)JP1 is the SPI (Serial Peripheral Interface) header. It allows access to the SPI pins (SS ¯¯¯ , MISO, MOSI, and SCK) to control the SPI registers of the LMH0387 equalizer. To use the SPI interactive GUI, plug the 6-pin parallel cable between this header and JP7 on the SPA dongle to connect the pins one-for-one as shown in Table 1. The SPA dongle requires special software and must be connected to the PC via the USB – see the Software Setup section.TABLE 1. SPI Connections between SD387 and SPA DongleSD387 JP1 SPA Dongle JP7 Pin # Name Pin # Name1 GND Æ 1 GND2 SCK Æ 2 MCK3 MOSI Æ 3 MOSI4 MISO Æ 4 MOSI5 SS Æ 5 SS6 GND Æ 6 GNDCarrier Detect LED (D1)D1 shows the status of Carrier Detect at the LMH0387 equalizer input. This LED is GREEN when an input signal has been detected at the BNC_IO pin, and OFF when no input is detected.SPA Dongle DescriptionThe SPA dongle is required to use the SPI interactive GUI. The SPA dongle connects between the LMH0387 SPI pins and the USB input of a PC. The SPA dongle is shown in Figure 2. JP7 is the SPI Header. The SPA dongle is powered through the USB, and the D1 LED is RED when the SPA dongle is connected to a PC via the USB to indicate the board is powered.FIGURE 2. SPA DongleFigure 3 shows the connection between the SD387 and the SPA dongle. For proper operation, the SPI pins must be connected between the SD387 JP1 and the SPA dongle JP7. Optionally, a single wire may be connected between the SD387 TX_EN pin (JP2) and the SPA dongle PA0 (J7) to enable software control of the LMH0387 cable driver enable functionality, and allow the GUI to fully control the LMH0387 I/O Mode as described on page 8. If this connection is not used, then the TX_EN can be controlled manually with a jumper.FIGURE 3. SD387 Connection to SPA DongleSoftware SetupSystem RequirementsOperating System:Windows XP or VistaUSB: 2.0InstallationDownload the latest software from the LMH0387 Evaluation Board page. Extract the ALPF_monthdayyear_major version_minor version.exe” (ex. ALPF_04062010_128_0002.exe) file to a temporary location that can be deleted later.Make sure the SPA dongle is not connected to the PC. The following installation instructions are for the Windows XP Operating System.Install the ALP softwareExecute the ALP Setup Wizard program called “ALPF_monthdayyear_major version_minor version.exe” (ex. ALPF_04062010_128_0002.exe) that was extracted to a temporary location.There are 7 steps to the installation once the setup wizard is started:1. Select the “Next” button.2. Select “I accept the agreement” and then select the “Next” button.3. Select the location to install the ALP software and then select the “Next” button.4. Select the location for the start menu shortcut and then select the “Next” button.5. There will then be a screen that allows the creation of a desktop and Quick Launch icon. After selectingthe desired choices select the “Next” button.6. Select the “Install” button, and the software will then be installed to the selected location.7. Uncheck “Launch Analog LaunchPAD” and select the “Finish” button. The ALP software will start if“Launch Analog LaunchPAD” is checked, but it will not be useful until the USB driver is installed.Connect JP1 of the SD387 evaluation board to JP7 of the SPA dongle via the 6-pin parallel cable as shown in Table 1. Power on the SD387 evaluation board with a 3.3 VDC power supply. Connect the SPA dongle to the PC with the USB cable. The “Found New Hardware Wizard” will open on the PC. Proceed to the next section to install the USB driver.Install the USB driverThere are 6 steps to install the USB driver:1. Select “No, not at this time” then select the “Next” button.2. Select “Install from a list or specific location” then select the “Next” button.3. Select “Search for the best driver in these locations”. Uncheck “Search removable media” and check“Include this location in the search”.4. Browse to the Install Directory which is typically located at “C:\Program Files\National SemiconductorCorp\Analog LaunchPAD\vx.x.x\Drivers” and select the “Next” button. Windows should find the driver.5. Select “Continue Anyway”.6. Select the “Finish” button.The software installation is complete. The ALP software may now be launched, as described in the next section.Software DescriptionStartupMake sure all the software has been installed and the hardware is powered on and connected to the PC. Execute “Analog LaunchPAD” from the start menu. The default start menu location is “Programs\National Semiconductor Corp\Analog LaunchPAD vx.x.x\Analog LaunchPAD”.The application should come up in the state shown in Figure 4 below. If it does not, see “Trouble Shooting” at the end of this document. Click on “LMH0387 – Nano” to select the device and open up the device profile and its associated tabs.FIGURE 4. ALP Startup Screen for the LMH0387Information TabThe Information tab is shown in Figure 5.FIGURE 5. LMH0387 Information TabFunctional TabThe Functional tab is the main tab of the GUI and presents a high level view of the LMH0387 equalizer, as shownin Figure 6.I/O Mode Controlprovided an additional wire is connected between the SD387 TX_EN and theSPA dongle PA0, as shown in Figure 3. The connection between TX_EN andPA0 allows software control of the LMH0387 cable driver enable functionality.If the SD387 TX_EN is not connected to the SPA dongle PA0, then TX_ENmay be controlled manually with a jumper and the I/O Mode Control will have no effect on the LMH0387 cable driver.The default LMH0387 I/O Mode setting is the Input (Rx) Mode, or equalizer mode. This default setting allows full control of the LMH0387 equalizer. The three I/O modes are described below.Input (Rx) Mode: Configures the LMH0387 for the input mode (equalizer enabled and cable driver disabled). This is the default setting. The LMH0387 equalizer is set to auto sleep, and if TX_EN is connected to PA0, then PA0 will drive TX_EN low to disable the LMH0387 cable driver. If this TX_EN Æ PA0 connection is not made, then the LMH0387 cable driver should be manually disabled by setting a jumper to tie TX_EN to GND.Output (Tx) Mode: Configures the LMH0387 for the output mode (cable driver enabled and equalizer disabled). The LMH0387 equalizer is forced to sleep. If TX_EN is connected to PA0, then PA0 will drive TX_EN high to enable the LMH0387 cable driver. If this TX_EN Æ PA0 connection is not made, then the LMH0387 cable drivershould be manually enabled by pulling the jumper between TX_EN and GND (TX_EN should be open).Tx Loopback Mode: Configures the LMH0387 for the output mode with a loopback path (cable driver andequalizer both enabled). The LMH0387 equalizer is set to auto sleep. If TX_EN is connected to PA0, then PA0 will drive TX_EN high to enable the LMH0387 cable driver. If this TX_EN Æ PA0 connection is not made, then theLMH0387 cable driver should be manually enabled by pulling the jumper between TX_EN and GND (TX_EN should be open). In this mode, the cable driver output on the BNC_IO pin is looped back to the LMH0387 equalizeroutputs (SDO and SDO¯¯¯¯ ), so the cable driver output may be observed both at BNC_IO pin and at the SDO/SDO ¯¯¯¯ output pins.The Cable Driver TX_EN indicator shows the current status of the TX_EN control (only if TX_EN is connected to PA0). It is GREEN to indicate TX_EN is driven high and the LMH0387 cable driver is enabled, or OFF to indicate TX_EN is driven low and the LMH0387 cable driver is disabled.Equalizer Sleep Mode and Carrier DetectThe Equalizer Sleep Mode control shows the status of the Sleep Mode register bits and allows control over the sleep mode. The Equalizer Sleep Mode settings are as follows:On: Force the equalizer into sleep mode (powered down) regardless of whether there is an input signal or not.Off: Disable sleep mode (force equalizer to stay enabled).Auto: Sleep mode active when no input signal detected (default mode).The Equalizer Sleep Status indicator shows the current sleep status of the equalizer. It is GREEN to indicate sleeping or OFF to indicate not sleeping.The Carrier Detect shows the status of the BNC_IO input carrier detect. It is GREEN to indicate the input signal is present or OFF to indicate the input signal is absent.Equalizer Output SwingThe Equalizer Output Swing control shows the current value of the LMH0387 equalizer output amplitude and allows adjustment in 100 mV increments from 400 mV P-P to 800 mV P-P . The default setting is 700 mV P-P . The Equalizer Output Swing may be set either by clicking on the “+” or “-” buttons, or by grabbing and spinning the “handle” on the knob for a quick adjustment.Equalizer Output OffsetThe Equalizer Output Offset control shows the current value of the LMH0387 equalizeroutput common mode voltage and allows adjustment in 200 mV increments from 1.05Vto 1.85V. At the “Max” setting, the outputs are referenced to the positive supply and theoutput common mode is 2.1V. The default setting is 1.25V. The Equalizer Output Offsetmay be set either by clicking on the “+” or “-”buttons, or by grabbing and spinning the“handle” on the knob for a quick adjustment.Equalizer Output MuteThe Equalizer Output Mute indicator shows the mute status, and the button may be used totoggle the mute function. The indicator is GREEN to indicate mute (equalizer outputs aremuted) and OFF to indicate normal mode (outputs are not muted).Extended 3G Reach ModeThe Extended 3G Reach Mode indicator shows the status of the Extended 3G ReachMode register bit, and the button may be used to toggle this register bit. The indicator isGREEN when the bit is set for extended 3G reach mode, and OFF when the equalizer isset for normal mode. Note that the indicator shows the status of the register bit – notwhether the device is actually in extended 3G reach mode or not. If extended 3G reachmode is set, the equalizer will remain in this mode until the input cable is physically changed or power is cycled. For example, extended 3G reach mode is forced, and then it is turned off. The indicator will show it is off, but the equalizer will still be in extended 3G reach mode until the input cable is changed or the device power is cycled. The GUI provides a simple way to reset the extended 3G reach mode: the Extended 3G Reach Mode Reset button. This button toggles the equalizer sleep mode, and has a similar effect to removing and re-applying the input cable.分销商库存信息: NATIONAL-SEMICONDUCTOR SD387EVK/NOPB。
Special Use Sensors - Weldable Strain GagesStandard Weldable PatternsMicro-Measurements For technical questions, contact: micro-measurements@Document Number: 11519Micro-Measurements Standard Weldable Strain Gages and Temperature Sensors are specially designed for spot welding to structures and components. They are ideal for applications where test or environmental conditions preclude clamping and curing an adhesively bonded gage installation.These gages are equally advantageous when strain measurements must be made at an elevated temperature,but the nature of the test object does not permit the use of an elevated-temperature-curing adhesive.Surface preparation requirements are minimal; only an appropriate solvent cleaning and abrasion of the test part surface with silicon-carbide paper or a small, hand-held grinder is needed. Spot welding is accomplished with a portable stored-energy hand-probe spot welder, such as the Model 700. Environmental protection is as easily applied to a welded gage installation as to an adhesively bonded gage.Refer to Instruction Bulletin B-131 and Catalog A-110 for further information on installation and protective coatings,and to Bulletin 302 for specifications on the Model 700Welding/Soldering Unit.DESCRIPTION AND PERFORMANCEGeneral — All sensors are laboratory-prebonded, with a high-performance adhesive, to thin (0.005 in [0.13 mm])metal carriers. Sensor grids are fully encapsulated for protection against handling and installation damage.Standard weldable strain gages are offered in two series to meet differing performance requirements. Both series are available in either 06 or 09 self-temperature compensation.Strain gages with 06 S-T-C have Inconel carriers, while S-T-C 09 gages and temperature sensors are mounted on 300-series stainless steel.CEA-Series Welda le Strain Gage —Polyimide-encapsulated constantan foil grid, with large, rugged,copper-coated tabs. In most cases, the carrier can be contoured to a radius as small as 1/2in [13mm]. The CEASeries is ideal for direct leadwire attachment, before or after installation.Strain range is ±5000µin/in [±5000µm/m], and normal operating temperature range is –100° to +200°F [–75° to +95°C]. Short-term maximum temperature is +300°F [+150°C].LWK-Series Weldab le Strain Gage — Nickel-chromium alloy grid, encapsulated in fiberglass-reinforced epoxy phenolic. The LWK gage is provided with a three-wire lead system with 10 in [250 mm] of Teflon ®-insulated leadwire.This construction simplifies leadwire temperature compensation and provides for easy connection of the lead system to the instrumentation cable. Minimum installation radius is generally limited to 2in [50 mm].Strain range is ±5000µin/in [±5000µm/m], and normal operating temperature range is –320° to +500°F [–195° to +260°C]. Short-term maximum temperature is +550°F [+290°C].WWT-Series Temperature Sensor — High-purity nickel foil grid encapsulated in fiberglass-reinforced epoxy-phenolic,and equipped with integral three-tab terminal to facilitate leadwire attachment. The temperature sensor is normally installed on a flat surface of the workpiece, but, in any case,should always be oriented with the gridlines in the direction of minimum strain to avoid strain-induced errors (see Micro-Measurements Tech Note TN-506, Bondable Resistance Temperature Sensors and Associated Circuitry).With an appropriate LST Matching Network, the temperature response characteristic of the nickel can be linearized and scaled for direct readout (in degrees) with any strain indicator.Teflon is a Registered Trademark of DuPont.MEASUREMENT CONSIDERATIONSIt is important to note that operating characteristics of weldable strain gages (gage factor, transverse sensitivity,and thermal output) are specified for the basic strain gage itself — without the metal carrier. Thus, the properties are measured by bonding a conventional strain gage directly to an appropriate calibration specimen, following standard methods specified for all Micro-Measurements strain gages. This procedure assures the most accurate results,independent of the variables introduced by welding. In particular, the user should be aware that the gage factor specified on the engineering data sheet accompanying the gage applies only to the basic strain gage, without the shim. The effective gage factor of the weldable assembly (after welding to the test member) is commonly 5 to 10%lower than this, due primarily to the stiffness of the shim.The reduction in gage factor is not subject to quantitative generalization, because it depends on the cross-sectional properties of the test specimen, and on the mode of loading (e.g., bending versus direct stress). It has been demonstrated, however, that for a group of like specimens, loaded in the same manner, the weldable gages exhibit very good repeatability and uniformity of response. Therefore, when test requirements dictate greatest accuracy, the weldable gages should be calibrated on a specimen of the same material and cross section as the test part, and under the same mode of loading.Special Use Sensors - Weldable Strain GagesStandard Weldable PatternsMicro-MeasurementsDocument Number: 11519For technical questions, contact: micro-measurements@Note 1: Products with designations and options shown in bold are not RoHS compliant.GAGE PATTERN AND DESIGNATIONInsert Desired S-T-C No. in Spaces Marked XX.See Note 1RES.IN OHMS.DIMENSIONSCARRIERACTIVE GRID MATRIX Length Width Thick Length Width Length Width CEA-XX-W250A-120CEA-XX-W250A-350120 ± 0.4%350 ± 0.4%0.630.340.0050.2300.1250.440.1716.08.60.135.843.1811.24.3Most flexible and conformable pattern. T ype 326-DFV and 330-DFV flat three-conductor cable typically used to solder directly to copper-coated tabs.CEA-XX-W250C-120CEA-XX-W250C-350120 ± 0.4%350 ± 0.4%0.900.900.0050.2300.1250.440.1722.922.90.135.843.1811.24.3Tee rosette, used in biaxial stress states where directions of principal stresses are known. See W250A pattern for typical leadwire recom-mendations.LWK-XX-W250B-350350 ± 0.4%0.880.320.0050.2500.1250.620.1722.48.10.136.353.1815.74.3Wide-temperature-range linear pattern with 10 in [250 mm] pre-attached leads. Teflon insulation is pretreated for best bond to protective coatings.LWK-XX-W250D-350350 ± 0.4%1.15 1.150.0050.2500.1250.620.1729.229.20.136.353.1815.74.3Tee rosette, used in biaxial stress states where directions of principal stresses are known and a wide operating temperature range is required.WWT -TG-W200B-05050 ± 0.4% @ +75°F [+24°C]0.710.430.0050.2000.2000.520.2618.010.90.135.085.0813.16.6Easy-to-use temperature sensor that can be welded or adhesively bonded to the test structure. For standard bondable temperature sensors, see Document Number 11522, “T emperature Sensors and LST Networks.”Vishay Precision GroupDisclaimerALL PRODUCTS, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE.Vishay Precision Group, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay Precision Group”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product.The product specifications do not expand or otherwise modify Vishay Precision Group’s terms and conditions of purchase, including but not limited to, the warranty expressed therein.Vishay Precision Group makes no warranty, representation or guarantee other than as set forth in the terms and conditions of purchase. To the maximum extent permitted by applicable law, Vishay Precision Group disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.Information provided in datasheets and/or specifications may vary from actual results in different applications and performance may vary over time. Statements regarding the suitability of products for certain types of applications are based on Vishay Precision Group’s knowledge of typical requirements that are often placed on Vishay Precision Group products. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application.No license, express, implied, or otherwise, to any intellectual property rights is granted by this document, or by any conduct of Vishay Precision Group.The products shown herein are not designed for use in life-saving or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay Precision Group products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay Precision Group for any damages arising or resulting from such use or sale. Please contact authorized Vishay Precision Group personnel to obtain written terms and conditions regarding products designed for such applications.Product names and markings noted herein may be trademarks of their respective owners.分销商库存信息: VISHAYLWK-06-W250B-350。
PNP Silicon High-Voltage TransistorBFN 23Maximum Ratings Type Ordering Code (tape and reel)Marking Package 1)Pin Configuration BFN 23Q62702-F1064HCsSOT-23BEC123ParameterSymbol Values Unit Collector-emitter voltage V CE0250VCollector-base voltageV CB0250Collector-emitter voltage,R BE = 2.7k ΩV CER 250Collector current I C 50mA Total power dissipation,T S =71˚C P tot 360mW Junction temperature T j 150˚CStorage temperature range T stg–65 … +150Thermal Resistance Junction - ambient 2)R th JA ≤ 290K/WJunction - soldering pointR th JS≤ 220Emitter-base voltage V EB05Peak collector currentI CM 1001)For detailed information see chapter Package Outlines.2)Package mounted on epoxy pcb 40mm ×40mm ×1.5mm/6cm 2 Cu.q Suitable for video output stages in TV sets and switching power supplies q High breakdown voltageq Low collector-emitter saturation voltage q Low capacitanceqComplementary type: BFN 22 (NPN)Electrical Characteristicsat T A = 25 ˚C, unless otherwise specified.UnitValues ParameterSymbolmin.typ.max.DC characteristicsVCollector-emitter breakdown voltage I C = 1mAV (BR)CE0250––Collector-base breakdown voltage I C = 10µAV (BR)CB0250––Emitter-base breakdown voltage I E = 10µAV (BR)EB05––nA µACollector-base cutoff current V CB = 200VV CB = 200V,T A = 150 ˚CI CB0––––10020µACollector cutoff current V CE = 250V,R BE = 2.7k ΩV CE = 250V,T A = 150 ˚C,R BE = 2.7k ΩI CER––––150–DC current gain 1)I C = 25mA , V CE = 20Vh FE 50––VCollector-emitter saturation voltage 1)I C = 10mA , I B = 1mAV CEsat ––0.5Base-emitter saturation voltage 1)I C = 10mA , I B = 1mA V BEsat––1Emitter-base cutoff current V EB = 5VI EB0––10Collector-emitter breakdown voltage I C = 10µA,R BE = 2.7k ΩV (BR)CER 250––MHz Transition frequencyI C = 10mA , V CE = 10V,f = 20MHz f T –100–pFOutput capacitance V CB = 30V,f = 1 MHzC obo–0.8–AC characteristics1)Pulse test conditions:t ≤ 300µs,D = 2 %.Total power dissipation P tot=f(T A*;T S) *Package mounted on epoxyPermissible pulse load P tot max/P tot DC=f(t p)Output capacitance C obo=f(V CE)f= 1 MHzTransition frequency f T=f(I C)V CE = 10VCollector current I C =f (V BE )V CE =20V Collector cutoff current I CB0=f (T A )V CB =200VDC current gain h FE =f (I C )V CE =20V。
Features• Dual N-Channel MOSFET • Low On-Resistance • Low Gate Threshold Voltage • Low Input Capacitance • Fast Switching Speed • Low Input/Output Leakage • Ultra-Small Surface Mount Package • Lead Free By Design/RoHS Compliant (Note 1) • ESD Protected up to 2KV • "Green" Device (Note 2) • Qualified to AEC-Q101 standards for High ReliabilityMechanical Data• Case: SOT363 • Case Material: Molded Plastic, “Green” MoldingCompound. UL Flammability Classification Rating 94V-0 • Moisture Sensitivity: Level 1 per J-STD-020 • Terminal Connections: See Diagram • Terminals: Finish - Matte Tin annealed over Alloy 42leadframe. Solderable per MIL-STD-202, Method 208 • Weight: 0.006 grams (approximate)Ordering Information (Note 3)Part Number Case Packaging DMN2004DWK-7SOT363 3000/Tape & ReelNotes: 1. No purposefully added lead.2. Diodes Inc.’s “Green” policy can be found on our website at .3. For packaging details, go to our website at .Marking InformationDate Code KeyYear 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 Code T U V W X Y Z A B C D EMonth Jan Feb Mar Apr MayJun Jul Aug Sep Oct Nov Dec Code 1 2 3 4 5 6 7 8 9 O NDSOT363Top ViewTop ViewInternal SchematicNAB = Marking Code YM = Date Code Marking Y = Year (ex: T = 2006) M = Month (ex: 9 = September) ESD PROTECTED TO 2kVNAB YM N A B Y MMaximum Ratings @T A = 25°C unless otherwise specifiedCharacteristic Symbol Value UnitsDrain-Source Voltage V DSS20 V Gate-Source VoltageV GSS±8 V Drain Current (Note 4)SteadyStateT A = 25°C T A = 85°CI D 540 390mAPulsed Drain Current (Note 5) I DM1.5 AThermal Characteristics @T A = 25°C unless otherwise specifiedCharacteristic Symbol Value UnitsTotal Power Dissipation (Note 4) P D 200 mW Thermal Resistance, Junction to Ambient R θJA 625 °C/W Operating and Storage Temperature Range T J, T STG -65 to +150 °CElectrical Characteristics @T A = 25°C unless otherwise specifiedCharacteristic Symbol Min Typ Max Unit Test ConditionOFF CHARACTERISTICS (Note 6) Drain-Source Breakdown Voltage BV DSS 20 ⎯ ⎯ V V GS = 0V, I D = 10μA Zero Gate Voltage Drain Current I DSS ⎯ ⎯ 1 μA V DS = 16V, V GS= 0V Gate-Source Leakage I GSS ⎯ ⎯ ±1 μA V GS = ±4.5V, V DS = 0V ON CHARACTERISTICS (Note 6)Gate Threshold Voltage V GS(th)0.5 ⎯ 1.0 V V DS = V GS , I D = 250μA Static Drain-Source On-Resistance R DS (ON)⎯ 0.4 0.5 0.7 0.550.70 0.9 Ω V GS = 4.5V, I D = 540mA VGS = 2.5V, I D = 500mA V GS = 1.8V, I D = 350mAForward Transfer Admittance |Y fs |200 ⎯ ⎯ ms V DS =10V, I D = 0.2A Diode Forward Voltage (Note 6) V SD0.5 ⎯ 1.4 V V GS = 0V, I S = 115mA DYNAMIC CHARACTERISTICSInput Capacitance C iss⎯ ⎯ 150 pF V DS = 16V, V GS = 0Vf = 1.0MHzOutput Capacitance C oss⎯ ⎯ 25 pF Reverse Transfer Capacitance C rss⎯ ⎯ 20 pF Notes:4. Device mounted on FR-4 PCB.5. Pulse width ≤10μS, Duty Cycle ≤1%.6. Short duration pulse test used to minimize self-heating effect.V , DRAIN-SOURCE VOLTAGE (V)Fig. 1 Typical Output CharacteristicsDS I , D R A I N C U R R E N T (A )D V , GATE-SOURCE VOLTAGE (V)Fig. 2 GS Reverse Drain Current vs. Source-Drain VoltageT , CHANNEL TEMPERATURE (°C)Fig. 3 Gate Threshold Voltage vs. Channel Temperaturech 0.1I DRAIN CURRENT (A)Fig. 4 Static Drain-Source On-Resistance Vs. Drain Current D ,1R , S T A T I C D R A I N -S O U R C E O N -R E S I S T A N C E ()D S (o n )ΩI , DRAIN CURRENT (A)Fig. 5 Static Drain-Source On-Resistance vs. Drain CurrentD R , S T A T I C D R A I N -S O U R CE O N -R E S I S T A N C E ()D S (o n )ΩI , DRAIN CURRENT (A)Fig. 7DOn-Resistance vs. Drain Current and Gate Voltage T , JUNCTION TEMPERATURE (C)Fig. 8 j °Static Drain-Source, On-Resistance vs. TemperatureI , D R A I N -S O U R C E L E A K A G E C U R R E N T (n A )D SS I , R E V E R S E D R A I N C U R R E N T (A )DR 1000I , DRAIN CURRENT (mA)DFig. 11 Forward Transfer Admittance vs. Drain Current|Y |, F O R W A R D T R A N S F E R A D M I T T A N C E(S )fs V , DRAIN SOURCE VOLTAGE (V)DS Fig. 12 Capacitance VariationPackage Outline DimensionsSOT363Dim Min Max A 0.10 0.30 B 1.15 1.35 C 2.00 2.20 D 0.65 Typ F 0.40 0.45 H 1.80 2.20 J 0 0.10 K 0.901.00 L 0.25 0.40 M 0.10 0.22α0° 8° All Dimensions in mmSuggested Pad LayoutIMPORTANT NOTICEDIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages.Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks.LIFE SUPPORTDiodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in thelabeling can be reasonably expected to result in significant injury to the user.B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness.Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.Copyright © 2011, Diodes IncorporatedDimensions Value (in mm)Z 2.5 G 1.3 X 0.42 Y 0.6 C1 1.9 C2 0.65XZYC1C2C2G分销商库存信息: DIODESDMN2004DWK-7。
KCB齿轮泵● 用途适用于输送不含固体颗粒和纤维,无腐蚀性,温度不高于80℃,粘度为5×10-6~1.5×10-3m2/s (5-1500cSt)的润滑油或性质类似润滑油的其他液体。
● 结构特性本系列齿轮泵主要有齿轮、轴、泵体、安全阀、轴端密封所组成。
齿轮经热处理有较高的硬度和强度,与轴一同安装在可更换的轴套内运转。
泵内全部零件的润滑均在泵工作时利用输出介质而自动达到。
泵内有设计合理的泄油和回油槽,是齿轮在工作中承受的扭矩力最小,因此轴承负荷小,磨损小,泵效率高。
泵设有安全阀作为超载保护,安全阀的全回流压力为泵额定排除压力的1.5倍,也可在允许排出压力范围内根据实际需要另外调整。
但注意本安全阀不能作减压阀的长期工作,需要时可在管路上另行安装。
从主轴外伸端向泵看,为顺时针旋转。
齿轮泵是在介质粘度4×10-3m2/s(40cSt)时确定的。
性能参数表中给出的参数值适用于介质粘度1×10-5~8×10-5m2/s(10~80cSt)范围内,超出这个范围则根据用户提出的性能参数要求另行确定。
各型齿轮泵性能参数中给出的排出压力是给出的最大的工作压力值,在此范围内泵均能正常工作,其工作范围见图一。
KCB系列齿轮油泵是有泵体、前后泵盖、齿轮、主被动轴、轴承、安全阀和轴端密封等零件组成。
KCB18.3——83.3主传动齿轮是一对斜齿园柱齿轮,直动式安全阀。
KCB200—960主传动齿轮是四个斜齿轮组成的人字形齿轮组,差压式安全阀。
全系列齿轮油泵用三爪式弹性联轴器与电动机组成的热油泵机组。
本系列齿轮油泵结构简单紧凑,使用维护方便,运转平稳,使用安全可靠。
● 适用范围本型齿轮油泵适用于输送介质粘度不大于150mm2/S ,温度不高于120°C,无腐蚀性,不含硬质颗粒杂质和纤维的重油、柴油、机械油、植物油以及性质类似的其它液体。
本型齿轮油泵主要用于石油、化工、冶金、矿山、电站等行业油类介质的转输、增压、燃油喷射等以及大型机械设备中稀油循环中,在各类机械设备中均可做润滑泵使用。
Material Safety Data Sheet*ZLB*SECTION 1 - PRODUCT IDENTIFICATION AND USEPRODUCT IDENTIFIER: 1Z-L, 8Z-L, 5B-LCATALOG NUMBERS: 99001123, 99001124, 99001125PRODUCT USE: Shaft Lubricant & Electrical Joint CompoundMANUFACTURERS NAME: Acheson Colloids Co. PHONE #: (810) 984-5581STREET ADDRESS: PO Box 77000 Dept. 771226CITY: Detroit STATE: Michigan ZIP CODE: 48277-1226DISTRIBUTORS NAME: TWECO Products, Inc. EMERGENCY PHONE #: (940) 566-2000STREET ADDRESS: 2800 Airport RoadCITY: Denton STATE: Texas ZIP CODE: 76207PREPARED BY: Terry Fulks PHONE NUMBER: (940) 566-2000 DATE PREPARED: October 31, 1990 DATE REVISED: January 31, 2007SECTION 2 - HAZARDOUS INGREDIENTSHAZARDOUS INGREDIENTS %/RANGE CAS NUMBER OSHA PEL ACGIH TLVGraphite(natural) 30 7782-42-5 15mppcf 2.5mg/m3 Mineral Oil 62+ 8012-95-1 5 mg/m3 5 mg/m3SECTION 313. SUPPLIER INFORMATIONTHIS PRODUCT DOES [ ] DOES NOT [X] CONTAIN TOXIC CHEMICALS SUBJECT TOTHE REPORTING REQUIREMENTS OF SECTION 313 OF THE EMERGENCY PLANNING ANDCOMMUNITY RIGHT-TO-KNOW ACT OF 1986 AND OF 40 CFR 372.CAS NUMBER CHEMICAL NAME %SECTION 3 - PHYSICAL DATAPHYSICAL STATE: Liquid ODOR AND APPEARANCE: Black Paste With Mineral OilOdor VAPOR PRESSURE(mm Hg): N.Av. VAPOR DENSITY(air=1): N.Av.EVAPORATION RATE: N.Av. BOILING POINT(F/C): >600F FREEZING POINT(F/C): N.Av.pH: N.Av. SPECIFIC GRAVITY: 0.9 SOLUBILITY: NegligibleSECTION 4 - FIRE AND EXPLOSION DATAFLAMMABILITY: Yes [X] No [ ] IF YES, MEANS OF EXTINCTION: Foam, CO2, DryChemical FLASHPOINT(F/C) AND METHOD: 450F C.O.C. FLAMMABLE LIMIT: N.Av.LEL: N.Av. UEL: N.Av. UNUSUAL FIRE AND EXPLOSION HAZARDS: NoneN.App.: NON APPLICABLE; N.AV.: NOT AVAILABLE; N.EST.: NOT ESTABLISHEDN.F.P.A. RATING SYSTEM: 0 - INSIGNIFICANT; 1 - SLIGHT; 2 - MODERATE;3 - HIGH;4 - EXTREMEHealth = 1 Flammibility = 1 Reactivity = 0 Special = _WHMIS CLASSIFICATION: CLASS "D" DIVISION 2 SUB-DIVISION "B"SECTION 5 - REACTIVITY DATACHEMICAL STABILITY: Yes [X] No [ ] IF NO, CONDITIONS TO AVOIDINCOMPATIBILITY WITH OTHER SUBSTANCES: Yes [X] No [ ] IF YES, WHICHONES? May react vigorously with oxidizing materialsHAZARDOUS POLYMERIZATION: Will Occur [ ] Will Not Occur [X]CONDITIONS TO AVOID: None known HAZARDOUS DECOMPOSITION PRODUCTS: CO, CO2ZLB Page 2SECTION 6 - HEALTH HAZARD DATAROUTE OF ENTRY: SKIN CONTACT [ ] SKIN ABSORPTION [X] EYE CONTACT [X]INHALATION [X] INGESTION [ ]EFFECTS OF ACUTE/CHRONIC EXPOSURE TO PRODUCT: Irritation of the eyes,Dermatitis CARCINOGENICITY: No SIGNS AND SYMPTOMS OF EXPOSURE: Irritationof the skin and eyes MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: Pre-existing skin disorders EMERGENCY AND FIRST AID PROCEDURES: SKIN: Washthoroughly with soap and water EYES: Flush immediately with water for15 minutes, get medical attention. INGESTION: No ill effects expectedINHALATION: No ill effects expectedSECTION 7 - PRECAUTIONS FOR SAFE HANDLING AND USELEAK AND SPILL PROCEDURE: Remove any source of ignition, scoop up as much aspossible, cover remainder with absorbent material & place in non-leakingcontainer for disposal. WASTE DISPOSAL METHOD: Dispose of in accordance withFederal, State & Local regulationsPRECAUTIONS TO BE TAKEN IN HANDLING AND STORING: Store away from sparks, openflames, or excessive heatSECTION 8 - CONTROL MEASURESRESPIRATORY PROTECTION: Not needed for this product. As required for cuttingand welding. GLOVES: Oil resistant RESPIRATOR: not needed EYE: Safetyor chemical goggles FOOTWEAR: N.App. CLOTHING: As required for weldingOTHER: N.Est.VENTILATION: Not normally needed WORK/HYGIENIC PRACTICES: Normal HygieneREFERENCES:"Chemical Guide To OSHA Hazard Communication Standard" First Edition"Handbook Of Toxic And Hazardous Chemicals and Carcinogens" Second Edition "Registry Of Toxic Effects Of Chemical Substances""NIOSH Pocket Guide to CHEMICAL HAZARDS" June 1994THIS DATA IS OFFERED IN GOOD FAITH AS TYPICAL VALUES. THIS IS NEITHER ANEXPRESSED NOR IMPLIED PRODUCT SPECIFICATION. RECOMMENDED HANDLING PROCEDURESAND HYGIENE ARE BELIEVED TO BE ACCURATE, HOWEVER, THESE RECOMMENDATIONS SHOULDBE REVIEWED IN THE SPECIFIC CONTEXT OF INTENDED USE AND DETERMINED APPROPRIATEBY THE USER.。
高效荧光增白剂KCB(C.I.367)
荧光增白剂 KCB,属苯并恶唑类型荧光增白剂,其化学名称为1,4-二(苯并恶唑基-2-基)萘,是一种通用型高效荧光增白剂。
规格:
化学名称:1,4-二(苯并恶唑基-2-基)萘
结构式:
外观:黄色粉末,呈鲜艳蓝亮白色光
分子量:362
含量:>99.5%
熔点:209-212℃
灰份:<0.1%
水份:<0.2%
细度:通过200目筛
用途:
荧光增白剂KCB 主要用于合成纤维与塑料制品的增白,对有色塑料制品有明显的增艳效果,可广泛用于塑料薄膜,压膜成型材料,注塑成型材料。
还可用于聚酯纤维,共聚物(EVA等),或者涂料,天然漆的增白,ABS,PVC等聚合物材料的加工,KCB的最大光谱吸收波长为370nm。
用量:
荧光增白剂KCB为目前众多的荧光增白剂的升级换代产品,具有使用方便,用量小及效果佳的特点。
在聚乙烯:聚氯乙烯(PVC);聚苯乙烯;ABS;聚乙烯树脂;EVA发泡制品中,用量为0.03%,即每100KG塑料原料投入量为30g左右,用户可依据产品要求作适当调整。
贮存:
本品为无毒,无臭,不易燃,无爆炸的安全产品。
按一般化工产品存放;不宜露天存放;与皮肤接触无刺激性,若沾上皮肤用清水加肥皂冲洗干净即可。
lLSI COUNTER CHIP WITH TIME BASE CHIP AND 0.35” (9 mm)HIGH LCD DISPLAYl SNAP MOUNTS DIRECTLY ONTO P .C. BOARD l SOLDERLESS, ELASTOMERIC INTERCONNECTS l ULTRA LOW POWER, 25 µA AT 3 V (Typical)l SELECTABLE TIME BASE FROM 3.9 MSEC TO 15.9 SEC l FREQUENCY DOUBLING CAPABILITY l SELECTABLE DECIMAL POINT POSITIONSlMASTER RESET TO SYNCHRONIZE TIME BASE WITH EXTERNAL FUNCTIONSDESCRIPTIONAs a completely self-contained tachometer/display module, the SUB-CUB-R can be treated as a component just like any other I.C. The module contains acustom monolithic counter/driver chip, a custom time base chip, and a 6-digit Liquid Crystal Display. The time base of the SUB-CUB-R is determined by the logic level of the Time Base Inputs and is selectable from approx 0.0039 second up to approximately 15.9 seconds in .0039 second increments. The SUB-CUB-R also allows for the selection of a decimal point position. The Master Reset input allows the user to synchronize the SUB-CUB-R time base with external operations.This module is ideal for internal “on board”applications where a readout ofrate or frequency is needed within a circuit enclosure for maintenance,diagnostic, tune-up, or other data readout requirements. The SUB-CUB-R can also be mounted with a convenient bezel kit to provide a very flexible and economical panel instrument.The SUB-CUB-R snap-mounts directly on to any 1/16” P.C. Board that has been etched to provide a mating interconnect pattern with two mounting holes and a polarizing “key”hole. Interconnections to the P.C. Board as well as internal connections are made with elastomeric connectors that provide corrosion-proof, gas-tight interface contacts for high reliability.SUB-CUB-R - COMPLETE 6-DIGIT COMPONENT RATE INDICATOR/FREQUENCY METERMOUNTING & DIMENSIONSSnap in mounting on the P.C. Board is facilitated by two, split, lock-ramp pins which engage mounting holes drilled in the P.C. Board. The silicone rubber elastomeric connectors compress to accommodate P.C. Board thickness variation of ±0.005”.DIMENSIONSIn Inches (mm)P .C. BOARD LAYOUTproper electrical contact can be made.Note: All hole size tolerances ±0.003” (0.08 mm)All other tolerances ±0.005” (0.13 mm)INTERNATIONAL HEADQUARTERSEUROPEAN HEADQUARTERS20 Willow Springs Circle, York, Pa. 17402, (717) 767-6511 FAX: (717) 764-0839892 Plymouth Road, Slough, Berkshire SL1 4LPWeb site- E-mail- sales@ ENGLAND +44 1753 696888 FAX: +44 1753 696339RED LION CONTROLSBULLETIN NO. SCUBR-A DRAWING NO. LP0178REVISED 3/97DEVICE CONNECTIONSTB12- CMOS *Pulsed Pull-up Latched input. When input is connected to V SS , 8 seconds is added to the total time base period. When input is connected to V DD or left open, no time is added to the total time base period.TB11- CMOS *Pulsed Pull-up Latched input. Adds 4 seconds to the total time base period when input is connected to V SS .TB10- CMOS *Pulsed Pull-up Latched input. Adds 2 seconds to the total time base period when input is connected to V SS .TB9- CMOS *Pulsed Pull-up Latched input. Adds 1 second to the total time base period when input is connected to V SS .TB8- CMOS *Pulsed Pull-up Latched input. Adds 1/2 second to the total time base period when input is connected to V SS .TB7- CMOS *Pulsed Pull-up Latched input. Adds 1/4 second to the total time base period when input is connected to V SS .TB6- CMOS *Pulsed Pull-up Latched input. Adds 1/8 second to the total time base period when input is connected to V SS .TB5- CMOS *Pulsed Pull-up Latched input. Adds 1/16 second to the total time base period when input is connected to V SS .TB4- CMOS *Pulsed Pull-up Latched input. Adds 1/32 second to the total time base period when input is connected to V SS .TB3- CMOS *Pulsed Pull-up Latched input. Adds 1/64 second to the total time base period when input is connected to V SS .TB2- CMOS *Pulsed Pull-up Latched input. Adds 1/128 second to the total time base period when input is connected to V SS.TB1- CMOS *Pulsed Pull-up Latched input. Adds 1/256 second to the total time base period when input is connected to V SS.DPA - CMOS *Pulsed Pull-up Latched input. When used along with DPB,selects the position of the decimal point.DPB - CMOS *Pulsed Pull-up Latched input. When used along with DPA,selects the position of the decimal point.F.D.- CMOS *Pulsed Pull-up Latched input. When input is connected to V SS ,Frequency Doubling is disabled. When input is connected to V DD or left open, Frequency Doubling is enabled.M.R.- CMOS Internally Pulled-up input. When input is connected to V SS ,Master Reset will terminate the present time base period. When MR is allowed to go high, the next time base period will begin. In normal use,MR is connected to V DD or left open. Note that this is not a Pulsed Pull-up Latched input.* See section on “Pulsed Pull-Up Latched Inputs” for more information .Note: For maximum noise immunity , connect all TB inputs to either V DD or V SS , whichever is appropriate. Inputs left open may change states in some noisey environments.SIG.- CMOS Schmidt trigger input. Counter chip increments on the falling edge of the Signal input when F.D. is connected to V SS (disabled).Counter chip increments on both rising and falling edges of the Signal input when F.D. is connected to V DD or left open (enabled).V DD - +2.5 to 6.0 VDC SupplyV SS - Common for D.C. Supply and Inputs.CAUTIONThis device contains CMOS circuitry which requires special anti-static handling to the same degree required by standard CMOS integrated circuits.Units should be stored in the conductive packaging used to ship the devices.Containers should be opened and units handled only on a conductive table top by personnel wearing wrist-strap grounding equipment. These devices have the same protection circuits as standard CMOS devices to prevent damage to inputs due to nominal over-voltage.RATINGSYMBOLVALUEUNITDC Supply Voltage V DD -0.5 to +6.5VDC Input Voltage, All Inputs V I -0.5 to (V DD +0.5)VDCOperating Temperature *T A -35 to +85oCStorage Temperature T STG -35 to +85oC *Extended high and low temperature ranges available, consult factory.MAXIMUM RATINGS (VOLTAGE REF. TO V SS )SYMBOLPARAMETERMIN.TYP .MAX.UNITTEST CONDITIONV DD Supply Voltage 2.5 6.0VDC I DD Supply Current 55µA 10 KHz signal, 1 second time base. All other inputs high.I DDQ Supply Current 45µA 1 second time base. All other inputs high.V SIH Input High Voltage 3.9 3.0VDC Signal input only.V SIL Input Low Voltage 0.90.5VDC Signal input only.V IH Input High Voltage 2.2VDC All other inputs.V IL Input Low Voltage 2.1VDCAll other inputs.I SIL Input Leakage 0.010.1µA V DD >V IN > V SS Signal input only.I IH Input High Current (source)50200µAAll other inputs.fc Signal Frequency 500KHzR PU Pull Up Resistance 50K W All pull-up inputs.T ACCTime Base Accuracy0.05%All time ranges.ELECTRICAL CHARACTERISTICS V DD = 5 V ±10% UNLESS OTHERWISE SPECIFIEDBLOCK DIAGRAMTIME BASE SELECTIONThe SUB-CUB-R has a time base selection range of approx. 3.9 msec to 15.9seconds in 3.906 msec (1/256 second) increments. The minimum time base setting is obtained by pulling only the TB1 input low while the maximum time base is obtained by pulling all TB inputs low. Therefore, a specific time base is achieved by adding the appropriate individual time base increments. The time base increment total is computed according to the following formula:= WHERE:DR =Desired ReadingDDP =Display Decimal Point RPM =Revolutions Per Minute PPR=Pulses Per Revolution DDP:0=1The Display Decimal Point (DDP) value is 0.0=10determined by the desired decimal point 0.00=100placement in the readout.DR x DDP x 15,360RPM x PPRTIME BASE INCREMENT TOTAL (TBIT)TIME BASE TIME BASE INPUTINCREMENTTB11TB22TB34TB48TB516TB632TIME BASE TIME BASE INPUTINCREMENTTB764TB8128TB9256TB10512TB111024TB122048DPBDPAD.P . LOCATIONLow Low Factory Test Mode OnlyLow High/Open 0High/Open Low 0.0High/Open High/Open 0.00EXAMPLE:Find the appropriate Time Base input settings for a desired display reading with a fixed shaft speed.DESIRED READING (DR)=250.0REVOLUTIONS PER MINUTE (RPM)=1250PULSES PER REVOLUTION (PPR)=50TBIT === 614.4TBIT = 614 (round off to the nearest whole number)TIME BASE INPUTREMAINDER NEEDEDTB10 (512). . . . . . . . . 614 - 512 = 102TB7 (64). . . . . . . . .102 - 64 = 38TB6 (32). . . . . . . . . 38 - 32 = 6TB3 (4). . . . . . . . . 6 - 4 = 2TB2 (2). . . . . . . . . 2 - 2 = 0As shown above, Time base inputs TB10, TB7, TB6, TB3, TB2 are pulled low to generate the desired time base. The actual time base in seconds is calculated by dividing the TBIT Total by 256.614/256 = 2.398 sec.FREQUENCY DOUBLINGFD is the Frequency Doubling input. When it is in the high state or left open,twice the number of input pulses are registered on the readout. This doubling of the signal input rate allows the Time Base Increment Total (TBIT) to be halved, thus allowing for a faster update time for a given display value. If this input is in the low state, Frequency Doubling is disabled.38,400,0062,500250.0 x 10 x 15,3601250 x 50DECIMAL POINT SELECTIONThe selection of the Decimal Point is accomplished by the DPA and DPBinputs. The table below shows the logic states which should be used to obtain the desired decimal point location. The SUB-CUB-R has leading zero blanking. Note that a change in decimal point position will only occur at the end of the present time base period.PULSED PULL-UP LATCHED INPUTSThe Time base inputs, the Decimal Point inputs, and the Frequency Doubling inputs are designed to be actuated by wired or switched connection to Common or by switching an open collector of a transistor to Common. A pull-up resistance is provided for all of these inputs. To keep current consumption to a minimum, this input circuit has been designed to latch the present state of the inputs, allowing the pull-up resistance to be switched on and off, thus reducing current consumption. The following is a description of the sequence of events for these inputs (Refer to the drawing below):At the end of a previous time base, a 30.5 µsec pulse is generated within the time base chip which will cause Q1 to switch ON the input’s pull-up resistance. During this time, if the input is being held low, the input will provide a sourcing current pulse thru Q1. The level of the input (either low or high)is sensed by the input’s Latching Circuit. When the pulse is terminated, the Latching Circuit will hold the input at its present state.If an input, which is presently in the high state, is pulled low, the Latching Circuit will respond immediately and latch the input in the low state. If an input is presently held in the low state, and is allowed to float,the Latching Circuit cannot respond until the end of the time base; at which time, the Pulsed Pull-up resistance will pull the input high. The Latching Circuit will then latch the high state. A Master Reset (MR) will terminate the present time base and allow new TB inputs to be latched.TYPICAL APPLICATIONSFLOW RATEThe SUB-CUB-R, along with some signal conditioning circuitry, can be used as a flow indicator to measure the flow of liquid. A flow gage with a magnetic type output is used to sense the rotation of the impellor,and its output is fed through an amplifier circuit to the SIG input. Since the output of the flow gage is an A.C. voltage, diodes D1 and D2 are used to clamp the output signal swing to within ±0.7 volts of the supply voltage. Diode D3 is used to prevent the voltage from rising above 6.0VDC to prevent damaging the SUB-CUB-R. The time base of the SUB-CUB-R is set to 0.5 sec (TB8 is connected to V SS ).Frequency doubling is enabled (FD is connected to V DD ).This will allow the meter to produce the appearance of a 1 second time base which updates twice a second. The time base of the SUB-CUB-R can be varied to produce different time bases required for different fluids. A second position decimal point is selected (DP A and DPB are connected to V DD ).DISPLAY FOR SPEED OF SMALL PRINTING PRESSThe SUB-CUB-R can be used to indicate the speed of the web of a small printing press in both tenths of feet per minute and in tenths of meters per minute. When the press is running at its maximum rate, the web is turning ata rate of 1800 RPM, and the press is running at 250 feet per minute (76.2meters per minute).The drive control produces a signal of 60 pulses per revolution of web. To align the registration marks in the set-up mode, the press speed is only 25 feet per minute.The controller for the press provides a logic pulse which corresponds to its speed. This logic pulse is fed through a buffer to the Signal input of the SUB-CUB-R. The time base is determined by the position of the Selector switch.In the first position, the SUB-CUB-R display will read out in tenths of feet per minute. In the second position, the display will be in tenths of meters. Note that Frequency Doubling is used to reduce the update time of the SUB-CUB-R. The first decimal point is turned on by the logic levels of DPA and DPB.To determine the proper TB input settings for both feet per minute and for meters per minute, use the following formula.=For Feet Per Minute:TBIT == 355.6= 177.8 ( ÷2 when using F.D.)= 178 (rounded off to the nearest whole number)TBIT = 178TB8. . . . . -128Needed =50TB6. . . . . -32Needed =18TB5. . . . . -16Needed =2TB2. . . . . -2Needed =0For Meters Per Minute:TBIT == 108.4= 54.2 ( ÷2 when using F.D.)= 54 (rounded off to the nearest whole number)TBIT = 178TB6. . . . . -32Needed =22TB5. . . . . -16Needed =6TB3. . . . . -4Needed =2TB2. . . . . -2Needed =076.20 x 10 x 15,3601800 x 60250.0 x 10 x 15,3601800 x 60DR x DDP x 15,360RPM x PPRTIME BASE INCREMENTTOTAL (TBIT)SUB-CUB-R PROTOTYPING BOARD (P/N DMOSCB04)This board is a handy way of doing experimental and prototyping work with the SUB-CUB-R. It easily plugs onto standard 0.1” spacing bread boards. This in turn, greatly simplifies bread board work.SUB-CUB-R PROTOTYPING BOARDP/N DMOSCB04PANEL BEZEL KIT FOR THE SUB-CUB-R (P/N HWK60000)This kit provides a convenient way to adapt the SUB-CUB-R for panel mounting. The kit includes the black plastic bezel, the panel and internal window gaskets, P.C. Board, 12” ribbon cable andmounting screws.ASSEMBLYDIMENSIONS & PANEL CUT-OUT “In inches (mm)PANEL CUT-OUT FRONT VIEWMODEL NO.DESCRIPTIONPART NUMBERSCUBR SUB-CUB Rate Indicator ModuleSCUBR200HWK 6*Panel Bezel Kit with P .C. Board & Cable HWK60000*Prototype P .C. BoardDMOSCB04*Does not include SUB-CUB-R Display/Rate Indicator Module.Order SUB-CUB-R separately.ORDERING INFORMATION分销商库存信息: RED-LION-CONTROLS DM-OSC-B04/A。
DRC230A-7Rotary actuator for butterfly valves• Torque motor Max. 90 Nm• Nominal voltage AC 100...240 V• Control Open/close• Running time motor 35 sTechnical dataElectrical data Nominal voltage AC 100...240 VNominal voltage frequency50/60 HzNominal voltage range AC 85...265 VPower consumption in operation 6 WPower consumption in rest position 2 WPower consumption for wire sizing11 VAConnection supply / control Cable 1 m, 3x 0.75 mm²Parallel operation Yes (note the performance data)Functional data Torque motor Max. 90 Nm (not constant)Manual override with push-button, can be lockedRunning time motor35 s / 90°Sound power level, motor60 dB(A)Position indication Mechanical, integratedSafety data Protection class IEC/EN II, reinforced insulationProtection class UL II, reinforced insulationDegree of protection IEC/EN IP54Degree of protection NEMA/UL NEMA 2Enclosure UL Enclosure Type 2EMC CE according to 2014/30/EULow voltage directive CE according to 2014/35/EUCertification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14Type of action Type 1Rated impulse voltage supply / control 2.5 kVPollution degree3Ambient humidity Max. 95% RH, non-condensingAmbient temperature-30...50°C [-22...122°F]Storage temperature-40...80°C [-40...176°F]Servicing maintenance-freeMechanical data Connection flange F07Weight Weight 3.8 kgDRC230A-7••••••••••Safety notesThis device has been designed for use in stationary heating, ventilation and air-conditioning systems and must not be used outside the specified field of application, especially in aircraft or in any other airborne means of transport.Outdoor application: only possible in case that no (sea) water, snow, ice, insolation or aggressive gases interfere directly with the device and that it is ensured that the ambient conditions remain within the thresholds according to the data sheet at any time.Caution: Power supply voltage!Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied with during installation.The switch for changing the direction of rotation may not be adjusted.The angle of rotation is not permitted to be subjected to mechanical limitation. It is forbidden to alter the mechanical end stops.The device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user.Cables must not be removed from the device.The device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed.Because of its non-constant torque, the actuator is neither suitable nor released formotorisation with valves from other manufacturers. No legal entitlement can be claimed, even after extensive testing. Belimo will not be held liable and will provide no warranty.Product featuresSimple direct mountingSimple direct mounting on the butterfly valve. The mounting orientation in relation to the butterfly valve can be selected in 90° (angle) increments.Manual overrideManual override with push-button possible (the gear train is disengaged for as long as the button is pressed or remains locked).High functional reliabilityThe actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached.Torque not constantDue to the non-linear torque characteristic the actuator can only be used for butterfly valvesand not for other armatures.AccessoriesElectrical accessoriesDescriptionType Auxiliary switch 1x SPDT add-on S1A Auxiliary switch 2x SPDT add-onS2A Feedback potentiometer 140 Ω add-on P140A Feedback potentiometer 1 kΩ add-on P1000A Feedback potentiometer 10 kΩ add-onP10000ADRC230A-7Wire colours:1 = blue 2 = brown 3 = whiteElectrical installationCaution: Power supply voltage!Wiring diagramsAC 230 V, open/closeDimensionsFurther documentation• The complete product range for water applications• Data sheets for butterfly valves• Installation instructions for actuators and/or butterfly valves• General notes for project planning。
SECTION 1: Identification of the substance/mixture and of the company/undertaking1.1. Product Identifier Product name Canon Ink Tank CLI-581XL< C >Product Code(s)2049C1.2. Relevant identified uses of the substance or mixture and uses advised against UseInk for Ink Jet Printer1.3. Details of the supplier of the safety data sheet Supplier ImporterCanon Europa N.V.Bovenkerkerweg 59, 1185XB Amstelveen, The Netherlands +31 20 5458545, +31 20 5458222Manufacturer Canon Inc.30-2, Shimomaruko 3-Chome, Ohta-ku, Tokyo 146-8501, Japan 1.4. Emergency Telephone Number *1 Kontakt Giftlinien på tlf.nr.: 82 12 12 12 (åbent 24 timer i døgnet). Se punkt 4 om førstehjælp.*2 Only for the purpose of informing medical personnel in cases of acute intoxications.*3 Ask for Poison InformationSECTION 2: Hazards identification2.1. Classification of the substance or mixtureClassification according to Regulation (EC) No 1272/2008Not classified2.2. Label ElementsLabelling according to Regulation (EC) No 1272/2008112Safety Data SheetMalta 112Bulgaria Netherlands +31 (0)30-2748888 [*2]112Poland 112Version : 03Portugal +351 808 250 143CroatiaRomania +40 21 318 36 06+385 (0)1-23-48-342Slovakia +421 2 5477 4166Slovenia 112Cyprus Spain1121401Sweden 112 [*3]Issuing date : 19-Apr-2017United Kingdom 111 (UK only)Czech Republic Iceland 112+420 224919293Liechtenstein 145Norway+47 22 59 13 00Denmark Switzerland145+45 82 12 12 12 [*1]Estonia 16662SDS # : ICW 1784 R - 03 EU ENFinland +358 (0)9 471977France +33 (0)1 45 42 59 59Greece +30 210 7793777Austria Hungary +36 80 20 11 99+43 (0) 1 406 43 43Italy+39 (0)55 7947819Revision date : 31-Aug-2018Latvia+371 67042473Belgium Lithuania +370 687 53378+32 (0) 70 245 245LuxembourgHazard pictogramsNot requiredSignal wordNot requiredHazard statementsNot requiredPrecautionary statementsNot requiredOther InformationContains 1,2-benzisothiazol-3(2H)-one.May produce an allergic reaction.Contains less than 30% of components with unknown hazards to the aquatic environment.2.3. Other HazardsNoneSECTION 3: Composition/information on ingredients 3.2. MixturesChemical name CAS-No EC-No REACH registrationnumber Weight %Classification (Reg.1272/2008)Note toOtherHazardsGlycol CBI CBI CBI10 - 15NoneGlycerin56-81-5200-289-5None 5 - 10NoneUrea compound CBI CBI CBI 5 - 10Eye Irrit. 2 (H319)Substituted phthalocyanine salt CBI CBI CBI 1 - 5Eye Dam. 1 (H318)Aquatic Chronic 3 (H412) Water7732-18-5231-791-2None60 - 80NoneFull texts of Hazard statement(s) are listed in SECTION 16Note to Other Hazards : The following substance(s) is (are) marked with (1), (2) and/or (3)- (1) Substance for which EU Occupational Exposure Limit(s) is (are) established (See SECTION 8)- (2) PBT substance or vPvB substance under Regulation (EC) No 1907/2006- (3) Substance listed in Candidate List of SVHC for Authorisation under Regulation (EC) No 1907/2006In case a safety data sheet supplied under (EC) No 1907/2006 Article 31-3 is necessary, please contact us.SECTION 4: First aid measures4.1. Description of first aid measuresInhalation Move to fresh air. Get medical attention immediately if symptoms occur.Ingestion Rinse mouth. Drink 1 or 2 glasses of water. Get medical attention immediately if symptomsoccur.Skin Contact Wash off immediately with soap and plenty of water. Get medical attention immediately ifsymptoms occur.Eye Contact Flush with plenty of water. Get medical attention immediately if symptoms occur.4.2. Most important symptoms and effects, both acute and delayedInhalation None under normal use. Symptoms of overexposure are dizziness, headache, tiredness,nausea, unconsciousness, cessation of breathing.Ingestion None under normal use. Ingestion may cause gastrointestinal irritation, nausea, vomitingand diarrhea.Skin Contact None under normal use.Eye Contact None under normal use. May cause slight irritation.Chronic Effects None under normal use.4.3. Indication of any immediate medical attention and special treatment neededNoneSECTION 5: Firefighting measures5.1. Extinguishing mediaSuitable extinguishing mediaUse CO 2, water, dry chemical, or foam.Unsuitable extinguishing mediaNone5.2. Special hazards arising from the substance or mixtureSpecial HazardNoneHazardous combustion productsCarbon dioxide (CO 2), Carbon monoxide (CO)5.3. Advice for firefightersSpecial protective equipment for fire-fightersNoneSECTION 6: Accidental release measures6.1. Personal precautions, protective equipment and emergency proceduresAvoid contact with skin, eyes and clothing.6.2. Environmental PrecautionsKeep out of waterways.6.3. Methods and material for containment and cleaning upWipe up with adsorbent material (e.g. cloth, fleece).6.4. Reference to other sectionsNoneSECTION 7: Handling and storage7.1. Precautions for safe handlingAvoid contact with skin, eyes and clothing. Clean contaminated surface thoroughly. Use with adequate ventilation.7.2. Conditions for safe storage, including any incompatibilitiesKeep in a dry, cool and well-ventilated place. Keep out of the reach of children. Keep away from direct sunlight. Keep away from heat and sources of ignition.7.3. Specific end usesInk for Ink Jet Printer. Obtain special instructions before use.SECTION 8: Exposure controls/personal protection8.1. Control parameters Exposure LimitsChemical nameEU OEL Austria Belgium Bulgaria Cyprus Glycerin 56-81-5None None TWA: 10 mg/m 3None NoneChemical nameCzech Republic Denmark Finland France GermanyGlycerin 56-81-5TWA: 10 mg/m 3Ceiling: 15 mg/m 3NoneTWA: 20 mg/m 3TWA: 10 mg/m 3DFG TWA: 200 mg/m 3inhalable fraction Ceiling / Peak: 400mg/m 3 inhalablefraction Chemical nameGreece Hungary IrelandItaly NetherlandsGlycerin 56-81-5TWA: 10 mg/m 3None TWA: 10 mg/m 3 mist STEL: 30 mg/m 3 mistNone None Chemical namePoland PortugalRomania Slovakia SpainGlycerin 56-81-5TWA: 10 mg/m 3inhalable fractionTWA: 10 mg/m 3 mist NoneNone TWA: 10 mg/m 3 mistChemical nameSweden United Kingdom Norway Switzerland Turkey Glycerin 56-81-5NoneTWA: 10 mg/m 3 mistNoneTWA: 50 mg/m 3inhalable dust STEL: 100 mg/m 3inhalable dustNone8.2. Exposure controlsAppropriate engineering controlsNone under normal use conditions.Individual protection measures, such as personal protective equipmentEye/face ProtectionNot required under normal use.Skin ProtectionNot required under normal use.Respiratory ProtectionNot required under normal use.Thermal hazardsNot Applicable SECTION 9: Physical and chemical properties9.1. Information on basic physical and chemical properties AppearanceCyan ; Liquid OdorSlight odorOdor threshold No data available pH7 - 9Evaporation RateNo data availableNo data availableFlash Point (°C)> 93.0°C (Tag. Closed Cup.); estimated Melting/Freezing point (°C)No data available Boiling Point/Range (°C)Flammability (solid, gas)Not Applicable Flammability Limits in AirUpper Flammability Limit None; estimatedLower Flammability Limit None; estimatedVapor pressure No data availableVapor density No data availableRelative density 1.0 - 1.1Solubility(ies)Water; misciblePartition coefficient: n-octanol/water No data available Autoignition Temperature (°C)None; estimated Decomposition Temperature (°C)No data available Viscosity (mPa s) 1 - 5Explosive properties None; estimatedOxidizing properties None; estimated9.2. Other InformationNo data availableSECTION 10: Stability and reactivity 10.1. ReactivityNone10.2. Chemical stabilityStable10.3. Possibility of Hazardous ReactionsNone10.4. Conditions to AvoidNone10.5. Incompatible materialsAcids, Bases, Oxidizing agents, Reducing agents.10.6. Hazardous Decomposition ProductsCarbon dioxide (CO 2), Carbon monoxide (CO), and/or Ammonia.SECTION 11: Toxicological information 11.1. Information on toxicological effectsAcute toxicity No data availableSkin corrosion/irritation Non-irritant (Estimate) (OECD Guideline)Serious eye damage/eye irritation Minimal irritant (Estimate) (OECD Guideline) Sensitization Non-sensitizer (Estimate) (OECD Guideline)Germ cell mutagenicity Ames test: NegativeCarcinogenicity No data availableReproductive Toxicity No data available STOT - single exposure No data available STOT - repeated exposure No data available Aspiration hazard No data available Other InformationNo data availableSECTION 12: Ecological information12.1. Toxicity Ecotoxicity effects No data available12.2. Persistence and degradability No data available12.3. Bioaccumulative potential No data available 12.4. Mobility in soil No data available12.5. Results of PBT and vPvB assessmentThis preparation contains no substance considered to be persistent, bioaccumulating nor toxic (PBT).This preparation contains no substance considered to be very persistent nor very bioaccumulating (vPvB).12.6. Other adverse effects No data availableSECTION 13: Disposal considerations13.1. Waste treatment methodsDispose of in accordance with local regulations.SECTION 14: Transport information14.3. Transport Hazard Class 14.1. UN numberNone None 14.4. Packing Group None14.5. Environmental Hazards Not classified as environmentally hazardous under UN Model Regulations and marine pollutant under IMDG Code.14.2. UN Proper Shipping Name 14.6. Special Precautions for usersIATA: Not regulatedNoneSECTION 15: Regulatory information15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture (EC) No 1907/2006 Authorisation Not regulated (EC) No 1907/2006 Restriction Not regulated (EC) No 1005/2009Not regulated (EC) No 850/2004Not regulated (EU) No 649/2012Not regulated Other InformationNone15.2. Chemical safety assessment NoneSECTION 16: Other informationFull text of H-Statements referred to under sections 2 and 3H318 - Causes serious eye damage H319 - Causes serious eye irritationH412 - Harmful to aquatic life with long lasting effectsKey literature references and sources for data- World Health Organization International Agency for Research on Cancer, IARC Monographs on the Evaluation on the Carcinogenic Risk of Chemicals to Humans- EU Regulation (EC) No 1907/2006, (EC) No 1272/2008, (EC) No 1005/2009, (EC) No 850/2004, (EU) No 649/2012Key or legend to abbreviations and acronyms used in the safety data sheet - PBT: Persistent, Bioaccumulative and Toxic - vPvB: very Persistent and very Bioaccumulative - SVHC: Substances of Very High Concern- EU OEL: Occupational exposure limits at Union level under Directive 2004/37/EC and (EU) 2017/2398, 98/24/EC, 91/322/EEC,2000/39/EC, 2006/15/EC, 2009/161/EU and (EU) 2017/164.- TWA: Time Weighted Average - STEL: Short Term Exposure Limit- GHS: Globally Harmonized System of Classification and Labelling of Chemicals - IARC: International Agency for Research on Cancer - IATA: International Air Transport Association - CBI: Confidential Business Information Issuing date :19-Apr-2017Revision date :31-Aug-2018Revision NoteSECTION 3 and 16 revisedThis product falls under (EC) No 1907/2006 Article 31-3.DisclaimerThe information provided on this SDS is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage,transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.14.7. Transport in bulk according to Annex II of MARPOL and the IBC CodeNot Applicable。
TB-02规格书版本V1.0版权©2019免责申明和版权公告本文中的信息,包括供参考的URL地址,如有变更,恕不另行通知。
文档“按现状”提供,不负任何担保责任,包括对适销性、适用于特定用途或非侵权性的任何担保,和任何提案、规格或样品在他处提到的任何担保。
本文档不负任何责任,包括使用本文档内信息产生的侵犯任何专利权行为的责任。
本文档在此未以禁止反言或其他方式授予任何知识产权使用许可,不管是明示许可还是暗示许可。
文中所得测试数据均为安信可实验室测试所得,实际结果可能略有差异。
蓝牙联盟成员标志归蓝牙联盟所有。
文中提到的所有商标名称、商标和注册商标均属其各自所有者的财产,特此声明。
最终解释权归深圳市安信可科技有限公司所有。
注意由于产品版本升级或其他原因,本手册内容有可能变更。
深圳市安信可科技有限公司保留在没有任何通知或者提示的情况下对本手册的内容进行修改的权利。
本手册仅作为使用指导,深圳市安信可科技有限公司尽全力在本手册中提供准确的信息,但是深圳市安信可科技有限公司并不确保手册内容完全没有错误,本手册中的所有陈述、信息和建议也不构成任何明示或暗示的担保。
文件制定/修订/废止履历表版本日期制定/修订内容制定核准V1.02019.11.28首次制定谢一骥目录一、产品概述 (5)二、电气参数 (7)三、外观尺寸 (9)四、管脚定义 (10)五、原理图 (12)六、设计指导 (12)七、回流焊曲线图 (15)八、包装信息 (16)九、联系我们 (16)一、产品概述TB-02智能照明模块是一款基于TLSR8250F512芯片设计的符合BT5.0低功耗Tmall Genie Mesh的蓝牙模块;该模块支持天猫精灵直接控制且拥有蓝牙mesh组网功能的蓝牙模块;设备之间通过对等星型网络通讯,采用蓝牙广播进行通讯,可保证多设备情况下响应及时。
它主要应用于智能灯控,可满足低功耗、低延时、近距离无线数据通信的要求。
V .92 Desktop Business ModemsBenefits• Increased upload speeds • V .34/33.6K Super G3 Fax • Globally approvedThe MultiModem ® ZBA V .92 business modem supports remote configuration, callback security , out of bandmanagement, as well as dial-up and 2-wire leased line connections making it the modem of choice for business applications. With V .92, this modem provides an increase in upload speeds and quicker connect times thantraditional V .90 modems. It offers V .34/33.6K fax and Error Correction Mode, that reduces fax transmission time by more than half when compared to traditional fax modems. In addition, all models are globally approved for use in many countries around the world. This means one model can ship virtually anywhere.Features• Vwith V .92 servers • Dial-up and 2-wire leased line support*• V .44 compression improves data throughput rates • Class 1.0 and Class 2.1 faxing at speeds to V .34/33.6K bps (Super G3)• Error Correction Mode (ECM) provides fast and reliable fax transmissions • CDC-ACM compliant for simple one-step installation• Out of band management available through factory settings or field configuration • Linux compatable • U.S. Caller ID reporting• Remote configuration for centralized setup and control• Callback Security for network security and reduced telephone toll charges**• Voice mail support and full-duplex speaker phone operation on voice models • Globally approved models for use in many countries worldwide • Small footprint and stackable design • Self-resetting lightning protection • Flash memory for easy updates • RS-232 or USB cable included • T wo-year warrantyMultiModem ®ZBA* USB model dial-up only .** RS-232 model only .SpecificationsRatesServer-to-client Data:USB Model: V .90 speeds when accessing a V .90 or V .92 Serial Model: Up to 48Kbps when accessing a V .92 serverClient-to-server Data:USB Model: Up to 50Kbps when accessing a V .92 serverSerial Model: Up to 48Kbps when accessing a V .92 serverClient-to-client Data: up to 33,6K bps Fax Data: up to 33,6K bpsStandardsModem Compatibility:USB Model: ITU-T V .92, V .90, V .34 enhanced, V .34, V .34bis, V .32, V .32bis, V .22; Bell 212A and 103; ITU-T V .21, V .42, V .42bis, V .44Serial Model: ITU-T V .92, V .90, V .34 enhanced, V .34, V .32bis, V .32, V .22bis, V .22; Bell 212A and 103/113; ITU-T V .21 & V .23; V .42, V .42bis, V .44Fax Compatibility: ITU-T “Super” Group 3, Class 1.0, 2.0, 2.1, T.4, T.30, V .21, V .27ter, V .29, V .34, V .17; TIA/EIA 578 Class 1, 2, TR29.2Error Correction: ITU-T V .42Data Compression:USB Model: ITU-T V .44, V .42bis, MNP 5 Serial Model: ITU-T V .44Flow Control: XON/XOFF (software), RTS/CTS (hardware)Voice Compatibility (-V models only): TIA/EIA IS-101Video: ITU-T V .80 for H.324 video conferencing (serial model only)ConnectorsRS-232 Model: 2 RJ-11s & DB25USB Model: 2 RJ-11s & 1 USB type BCablesRS-232 Model: 1 RS-232 cable & 1 RJ-11 cable USB Model: 1 USB cable & 1 RJ-11 cableOperationRS-232 Model: Async/230.4K bps Dial-up or 2-wire leased lineUSB Model: USB 1.1/12M bps Dial-upOperating System SupportWindows 2000/XP/2003/Vista/2008/7(32-bit/64-bit), Linux, & Mac OS 10.4 or greater USB Model: CDC-ACM compliantHighlightsIncreased Upload Speeds. With the V .92 MultiModem ZBA business modem, you can achieve an upload speed of 48K bps (30% increase over V .90 modems). This higher upstream speed reduces data transfer time for large e-mails with attachments and for ftp site uploads, as well as improves operation for interactive applications.V.44 Compression. V .44 compression enables data throughput rates of higher than 300K bps - much faster than V .42bis data compression rates of 150 - 200K bps. For users, it means that your Web browsing will be much faster.Enhanced Fax Features. The MultiModem ZBA business modem supports V .34 fax and Error Correction Mode providing significant performance and reliabilityenhancements over previous fax standards. V .34 sends and receives faxes at 33.6K, more than double the speed of the V .17/14.4K fax standard. Error Correction Mode adds reliability while increasing performance of fax transmissions. Together these enhancements increase the performance of the modem to levels previously only found in more expensive dedicated fax boards and machines.Remote Configuration. Whether you provide connectivity for a sales office just miles away or for multiple offices around the world, the MultiModem ZBA business modem lets you take care of the configuration from a central site.Callback Security. The MultiModem ZBA business modemprovides password protection and helps reduce long distance charges for remote offices and users requiring access to the central site LAN. This modem supports 30 passwords and three configuration options. With the "fixed" callback option, the central site modem stores a password and the remote user's phone number. Once the remote site enters their password, the central site's modem calls back using the number stored in its database. The "variable" option lets users, such as road warriors, enter their fixed password and a call back number each time they call. The "pass through" option is used to provide the security of password protection, while bypassing the call back process.Global Approvals. With the globally approved MultiModem ZBA business modem, you need just one modem for worldwide use. This model has approvals in many countries so you can ship one SKU (stock unit) virtually anywhere in the prehensive Service and Support. The Multi-Techcommitment to service means we provide a two-year product warranty and service that includes free technical support, 24-hour web site and ftp support.World Headquarters Tel: (763) 785-3500 (800) 328-9717 EMEA HeadquartersMulti-Tech Systems (EMEA)United KingdomTel: +(44) 118-959 7774Ordering InformationProduct Description RegionMT9234ZBA-IEC* V.92 Data/Fax World Modem GlobalMT9234ZBA-IEC-OBM** V.92 Data/Fax World Modem GlobalMT9234ZBA-NAM V.92 Data/Fax World Modem GlobalMT9234ZBA-EU V.92 Data/Fax World Modem GlobalMT9234ZBA-GB/IE V.92 Data/Fax World Modem GlobalMT9234ZBA-V-NAM V.92 Voice/Data/Fax World Modem GlobalMT9234ZBA-V-EU V.92 Voice/Data/Fax World Modem GlobalMT9234ZBA-V-GB/IE V.92 Voice/Data/Fax World Modem GlobalMT9234ZBA-V-IEC* V.92 Voice/Data/Fax World Modem GlobalMT9234ZBA-USB-CDC V.92 Data/Fax World Modem Global* Ships without power cord and telco adapter. Localization kit sold separately.** -OBM -out of band management.Copyright © 2011 by Multi-Tech Systems, Inc. All rights reserved.7/11 86002093Produced in the US of US and non-US components.Features and specifications are subject to change without notice.Trademarks / Registered Trademarks: MultiModem, Multi-Tech, and theMulti-Tech logo: Multi-Tech Systems, Inc. / All other products and technologies are the trademarks or registered trademarks of their respective holders.Physical Description & Operating Environment4.3" w × 1.2" h ×5.8" d; 8 oz(10.8 cm × 2.9 cm × 14.8 cm; 227g)+32° to +120° F (0° to +50° C); 20-90% noncondensing ApprovalsCE MarkEMC: EN 55022/FCC Class B, EN 55024Safety: c/UL 60950-1 2nd Ed, IEC 60950-1 2nd Ed, CCC & NALTE, AS/NZS 60950:2000Telecom: 47CFR Part 68, CS-03, R&TTE, NALTE, A-Tick Other countries also included。
半自动凯氏定氮仪技术指标1. 货品名称:半自动凯氏定氮仪2. 重要用途:用于肥料或复混肥中旳氮及粗蛋白质含量旳分析,及其他挥发性组分蒸馏分析。
3. 工作条件:持续工作8小时以上.4. 技术指标:4.1采用国际及中国国标旳凯氏定氮措施:浓硫酸消化、碱性环境蒸汽蒸馏、硼酸吸取、指示剂滴定终点颜色鉴定法4.2检测范围:0.1-200mg 氮;回收率≥99.5%(1-200mgN);重现性RSD≤1%4.3 定氮仪主机内置操作系统,液晶显示屏操作,带中英文操作界面。
带自动蒸馏控制系统,包括:样品稀释、碱液添加、自动蒸馏以及消化管自动排空。
4.4 蒸汽发生器输出功率可调,具有待机功能:可在暂停后迅速启动分析,减少预热时间。
4.5 蒸馏馏出液温度监控系统,直接监控溜出液温度,保证分析成果精确可靠。
4.6冷却水智能控制系统:可在不分析时自动停止进水,分析启动时自动调整冷却水旳流量,节省冷凝水消耗,减少运行成本。
4.7智能安全监控系统:包括安全门、试管在位和试管更换传感器、蒸汽发生器液位/过压传感器等一系列旳安全保护措施,保证数据分析及操作者安全。
4.8通用型消化管接头:一种消化管接头即可适配100ml/250ml/400ml/750ml消化管,满足不一样分析需要。
4.9 消化能力: 每批8个样品,可选用100ml、250ml、400ml消化管4.10 消化炉:8位铝模块式整体加热,内置数字式控温系统,多语言顾客操作界面(含中英文),可以对消化参数-温度及时间进行设定及控制,带有超温保护装置。
4.11定氮仪内碱泵采用高精度定量泵,精度规定:SD=0.2ml (在50ml加液量时)5. 基本配置:5.1 消化系统一套:8位铝模块式整体加热,内置数字式控温系统,可以对消化参数-温度及时间进行设定及控制,带有超温保护装置。
带废气排放装置。
5.2定氮仪主机一台:内置操作系统,液晶触摸屏控制,带中英文操作界面。
具有超温超压保护旳内置全自控蒸汽发生器,蒸汽发生器输出功率可调,具有待机功能:可在暂停后迅速启动分析,减少预热时间。
Xofigo® (radium Ra 223 dichloride)Document Number: IC-0172 Last Review Date: 07/01/2018Date of Origin: 09/05/2013Dates Reviewed: 06/2014, 03/2015, 05/2015, 8/2015, 11/2015, 2/2016, 5/2016, 8/2016, 8/2017, 7/2018I.Length of AuthorizationCoverage will be provided for six months (6 injections only) and may NOT be renewed.II.Dosing LimitsA.Quantity Limit (max daily dose) [Pharmacy Benefit]:-N/AB.Max Units (per dose and over time) [Medical Benefit]:∙178 billable units every 28 daysIII.Initial Approval CriteriaCoverage is provided in the following conditions:Prostate Cancer †∙Patient is 18 years or older; AND∙Patient has castration-resistant disease; AND∙Patient has symptomatic bone metastases; AND∙Patient does not have any known visceral metastatic disease; AND∙Must be used as a single agent†FDA Approved Indication(s)IV.Renewal CriteriaCoverage is not renewable.V.Dosage/AdministrationVI.Billing Code/Availability InformationJcode:A9606 – Radium ra-223 dichloride, therapeutic, per microcurie: 1 billable unit = 1 microcurieNDC:Xofigo (radium Ra 223 dichloride injection) is supplied in single-use vials containing 6 mL ofsolution at a concentration of 1,100 kBq/mL (30 microcurie/mL) with a total radioactivity of 6,600 kBq/vial (178 microcurie/vial) at the reference date (NDC 50419-0208-01).VII.References1.Xofigo [package insert]. Wayne, NJ; Bayer HealthCare; February 2018. Accessed May 2018.2.Referenced with permission from the NCCN Drugs & Biologics Compendium (NCCNCompendium®) for Prostate Cancer 2.2018. National Comprehensive Cancer Network, 2018.The NCCN Compendium® is a derivative work of the NCCN Guidelines®. NATIONALCOMPREHENSIVE CANCER NETWORK®, NCCN®, and NCCN GUIDELINES® aretrademarks owned by the National Comprehensive Cancer Network, Inc.” To view the mostrecent and complete version of the Compendium, go online to . Accessed May 2018.3.Palmetto GBA. Local Coverage Article for Xofigo Billing Instructions (A54559). Centers forMedicare & Medicaid Services, Inc. Updated on 02/26/2018 with effective date 2/26/2018.Accessed May 2017.Appendix 1 – Covered Diagnosis CodesAppendix 2 – Centers for Medicare and Medicaid Services (CMS)Medicare coverage for outpatient (Part B) drugs is outlined in the Medicare Benefit Policy Manual (Pub. 100-2), Chapter 15, §50 Drugs and Biologicals. In addition, National Coverage Determination (NCD) and Local Coverage Determinations (LCDs) may exist and compliance with these policies is required where applicable. They can be found at: /medicare-coverage-database/search/advanced-search.aspx. Additional indications may be covered at the discretion of the health plan.Medicare Part B Covered Diagnosis Codes (applicable to existing NCD/LCD):。