RMBridge 过程指南
- 格式:pdf
- 大小:3.55 MB
- 文档页数:33
迅达A P M M R现场安装手册SANY标准化小组 #QS8QHH-HHGX8Q8-GNHHJ8-HHMHGN#安装缩略图摘要本手册提供了在亚太区范围内使用脚手架安装300P MMR主要安装步骤的详细说明。
本手册为保密文件,并仅供授权的培训人员使用。
目录1 安全建议 (4)概要 (4)使用符号 (4)2 先决条件 (5)产品概述 (5)安装步骤 (7)专用工具 (9)3 施工现场准备工作 (10)4 导轨安装 (15)准备工作 (15)导轨支架安装 (15)导轨安装 (21)导轨基座 (21)导轨安装 (22)连接板校正 (24)5 Varidor 30AP C2 厅门入口安装 (25)门框预安装 (27)地坎支架 (30)门框和机械横梁 (31)地坎和护脚板 (35)门板 (36)C2井道互锁装置 (40)门解锁装置 (41)安装门重锤 (42)防护罩 (44)6 PMS420无齿轮机组安装 (45)机组支架 (47)安装PMS420无齿轮机组 (48)*手动应急操作选配装置 (51)制动器调整和制动力测试 (57)*曳引钢丝绳悬挂装置安装 (58)*安装限速器 (62)7 *安装GGM2-AP对重 (71)先决条件 (71)*机械安装 (72)*缓冲器支撑 (72)*对重校正 (73)*安全钳(选配) (74)*导靴 (76)油杯(选配) (79)*对重块 (79)*补偿链悬挂装置 (80)地震传感器(选配) (81)*调整和最后检查 (82)对重防护屏 (83)*对重防护屏后置 (83)*对重防护屏侧置 (84)8 安装轿厢架FRS9-AP/FRM9-AP (87)安装轿厢架FRS9-AP (87)FRS9-AP安全钳和导靴选配件 (98)FRM9-AP安全钳和导靴选配件 (99)9 安装曳引绳 (100)处理钢丝绳 (100)安装钢丝绳 (101)钢丝绳绳头安装 (105)检查钢丝绳张紧度和绳的润滑 (109)限速器钢丝绳 (110)10 轿厢P9KD-AP(CM)安装 (117)轿厢安装步骤 (118)*安装轿厢装璜 (134)安装满载、超载开关 (143)轿厢平衡装置 (144)11 V30 AP轿门安装 (145)11.1 C2轿门 (145)11.1.1 轿门机驱动 (146)11.1.2 轿门板 (147)11.1.3 轿门刀 (149)安装光幕(MiniMax光幕LVH) (151)12 安装缓冲器 (157)13 安装补偿链 (159)补偿链导向装置 (159)4-滚轮导靴 (159)2-滚轮导靴 (162)补偿链 (165)14 安装MX-GC (170)先决条件 (170)材料范围 (171)控制柜 (172)井道信息 (174)井道信息IGSI (174)绝对值线型井道信息系统 (190)控制柜内模块 (210)机房电缆 (211)井道电缆 (215)准备 (220)安装 (223)调整和最后检查 (229)OKR (231)随行电缆 (236)带IGSI和LONCIB的MX-GC,HQ<=70m (237)带IGSI和LONCIB的MX-GC,HQ>70m (238)带IGSI和LONIC/LONICK的MX-GC,HQ<=70m (239)带IGSI和LONIC/LONICK的MX-GC,HQ>70m (240)控制柜内的概述与名称 (241)15 VARIODYN VF44BR和VF88BR安装 (243)VARIODYN VF44BR安装 (243)VARIODYN VF88BR安装 (249)1 安全建议概要安全要求所有参与的安装人员必须熟悉并遵守公司以及当地的安全规范,特别要注意以下几点:照明必须充足,以保证安全生产。
BridgeOS操作系统技术宝典开发单位:北京盈捷万通网络智能设备有限公司公司地址:北京朝阳区十八里店南桥自主城1号楼8层进入BridgeOS操作系统BridgeOS是一个操作系统(Bridge Operating System)。
21世纪初开发研制的互联网业务化软硬件产品。
主要用于ISP(互联网接入提供商Internet Service Provider)的接入业务平台和技术实现平台,由X86硬件计算构架和自主研发的bridge操作系统相结合的软硬件于一体的商业化产品。
区别于交换机、路由器的网桥操作系统。
交换机根据MAC地址进行转发,路由器根据IP地址进行转发,网桥根据端口进行转发,默认情况下BridgeOS是一对一模式的网桥设备(一台设备有多个桥),可以自由配置成一对多或是多对一的网桥。
支持常用的WEB、Telnet、console等管理方式。
BridgeOS需要授权获得License后才能正常工作。
功能简表:BridgeOS系统以接口形式对系统进行管理,一共包括3种接口类型:物理接口、桥接口和PPPoE接口。
根据不同接口类型,每种接口的个数不同。
其中,物理接口有8个,对应着8个千兆以太网物理接口,桥接口有4个,对应着4个网桥,PPPoE接口可有4个,对应着4个PPPoE服务的配置。
如下表。
网桥的默认VLAN特性:VLAN穿透LAN/WAN方向的数据包保持原VLAN不变,对VLAN直接穿透。
SFP部署过程过中VLAN的穿透要关闭SFP的对VLAN的处理方法如下:hardware features vlan force-offBRI#configure terminalBRI(conf)#interface gigabitethernet 0/0BRI(conf)#hardware features vlan force-offBRI(conf)#exit注:只有SPF才需要关闭vlan features为了便于阅读,BridgeOS操作系统采用配置模式对设备上的配置进行分类管理。
OPCBridge使⽤说明OPCBridge 使⽤⼿册⽬录1 前⾔....................................................................................................................... - 1 -1.1声明 (1)1.2技术⽀持 (1)2概述........................................................................................................................ - 1 -2.1功能描述 (1)2.2运⾏环境 (2)2.3应⽤领域 (2)3使⽤说明 ............................................................................................................... - 3 -3.1产品的使⽤(建⽴⼀个简单的⼯程) (3)3.1.1选择需要连接的⽬标OPC服务器................................................... - 3 -3.1.2新建组,新建标签(标签可多选添加)......................................... - 4 -3.1.3关联Modbus的寄存器类型和寄存器地址 ..................................... - 7 -3.2M ODBUS客户端软件M ODBUS P OLL连接测试 (10)3.2.1 modbus poll 参数设置..................................................................... - 10 -3.2.2 modbus poll 测试访问..................................................................... - 12 -3.3保存⼯程⽂件 (14)3.4导⼊导出标签功能 (14)3.5EXCEL打开导出的⽂件(可以编辑再次导⼊) (15)4 USB 硬件狗的使⽤............................................................................................ - 16 -5 SFWATCHDOG.EXE的使⽤ ........................................................................... - 17 -6 VISUAL BASIC脚本的使⽤ ............................................................................ - 18 -7 WEB的使⽤ ....................................................................................................... - 19 -1 前⾔1.1声明本⼿册属于上海迅饶⾃动化科技有限公司及授权许可者版权所有,保留⼀切权利,未经本公司书⾯许可,任何单位和个⼈不得擅⾃摘抄、复制本书内容的部分或全部。
Quick Start Guide for installation asVirtual ApplianceThis quick start guide walks you through installing the IBM Hyper-Scale Manager VM and using it with the IBM Storage XIV Management (XIV GUI).This is an *.ovf installable virtual appliance for VMWare hypervisor.This installation type is intended for storage administrators that are not familiar with Linux and can use VMWare resources in their organizations.Almost no pre-requisites are needed here as you cannot access the OS shell beside running pre-prepared scripts using a main menu. Everything is configured almost automatically, while running a wizard to ease the installation.1: Installing the IBM Hyper-Scale Manager VMPrior to the configuration of the IBM Hyper-Scale Manager, you need to install the virtual machine itself. This installation deploys the ovf image of the IBM Hyper-Scale Manager on your VMWare ESX.1.Prepare a virtual machine (these specifications are also listed on the IBM Hyper-Scale Manager Release Notes):∙Memory and vCPU:▪Up to 60 XIV systems – 4 GB; dual core▪61-100 XIV systems – 6 GB; quad core▪101-120 XIV systems – 6 GB; six core▪121-144 XIV systems – 8 GB; six core∙ESX Server versions - 4, i4, 4.1, i4.1, i5∙VM disk size – 76 GB∙Ports that need to be opened:▪Outbound/Inbound: RMI - 1199-1209▪Inbound only: SSH/SCP - 22▪Outbound only: SMTP - 25o Communication with XIV systems - 7778o RESTful API port – 8443∙Allowed latency between the IBM Hyper-Scale Manager and the XIV systems it monitors: max of 200 ms∙Maximum number of GUI concurrently connected to one server – 15∙Max XIV Systems administered by one server - 1442.The installation procedure will ask for the following information. Record it in the space provided:∙Networking configuration: You can either work with DHCP or with Static IP.In case you work with Static IP, please prepare: IP Address and netmask, gateway and DNS parameters related to thestatic IP.∙Hostname __________∙ A new password for ‘root’ (the default password: xivmsRoot) _________∙NTP servers (if any) __________∙SMTP address (not mandatory) ___________3.Download the file named: IBM-Hyper-Scale-Manager_<version>.zip.4.Unzip it to your local PC that has accessibility to VMWare vSphere client.5.Fine tune the VM resources according to the specifications on step 1 above.6.Deploy the *.ovf file supplied in the ZIP using Deploy OVF Template in the ESX vSphere Client. Follow the link for instructions(steps 1-11 only).Notes:∙The virtual machine will consume 76 Gb of free space.∙You may see some warnings related to compatibility. Please ignore them and approve.7.Power on the VM.8.On the VMWare console, login with: user=root, password=xivmsRoot.9.The wizard opens on screen. Follow the steps on the next section.2: Configuring the IBM Hyper-Scale Manager on the VMThe wizard welcome screen guides you through the steps of the configuration.1.Click Enter to view the IBM Hyper-Scale Manager license agreement.Click 1 to approve it or 2 to decline.2.Change the 'root' password.3.Set up the network configuration. Configure with Static IP, or DHCP.4.Set up the NTP and regional settings.a.Optionally, set the timezone.b.Change the date & time, alternatively, add an NTP server.5.Set up the SMTP connectivity. Enter the SMTP server address and SMTP server port and approve.6.The IBM Hyper-Scale Manager is now installed and configured.7.Please provide the IBM Hyper-Scale Manager IP Address / hostname to the Storage Administratorin order to continue to Step 3:∙IP address __________∙Hostname __________3: Initializing the IBM Hyper-Scale Manager InventoryThis step is for the XIV storage administrator.Make sure you have the IBM Hyper-Scale Manager server IP Address / hostname.1.Export a list of the XIV systems you are currently using:∙If you have a previous version of IBM XIV GUI: Export the list from the Systems > Export Systems File dialog on the GUI∙If you don’t have an IBM XIV GUI, go to step 2.2.Install IBM XIV GUI 4.3.unch the GUI in Direct mode (direct mode means connecting an XIV system directly to the GUI) by selecting direct on theMode field of the Login screen.4.Connect the XIV GUI to the IBM Hyper-Scale Manager through the Systems > Preferences dialog.5.If you have exported the systems list on step 1 (above), open the Systems > Import Systems File to import the systems list. Else,add the systems / groups manually. You can do both through the Systems > Manager Configuration > Inventory dialog.The default Manager Access Code is adminadmin.You are ready to work with your XIV GUI using IBM Hyper-Scale Manager to enjoy Multi-System features.More informationThe complete set of installation instructions is available on the IBM Hyper-Scale Manager for Virtual Appliance Version 1.4.This user guide and all other XIV documentation are available on the Information Center:IBM® XIV® Storage System Information Center websiteIBM XIV IBM Hyper-Scale Manager 1.4 Licensed Materials - Property of IBM. © Copyright IBM Corp. 2013. U.S. Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.IBM, the IBM logo, and are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" (/legal/copytrade.shtml).。
Symphony 64 |ThunderBridgeQuickStart GuideV1, March, 2013ContentsOverview!5.........................................................................................................Introduction!5Package Contents!6Symphony 64 | ThunderBridge Tour!8 System Requirements!10..................................................................................Connecting to your Mac!12..............................................................................Install Symphony Software!12Connecting Multiple Apogee Interfaces!17Connecting Multiple Thunderbolt Devices!20 Software Setup!22.............................................................................................Using the Symphony System with Apple Logic!22Using the Symphony System with Avid Pro Tools!24 Troubleshooting!26...........................................................................................Additional Support!27.......................................................................................OverviewIntroductionThank you for purchasing Apogee’s Symphony 64 | ThunderBridge. This QuickStart guide describeshow to setup Symphony 64 | ThunderBridge with your Thunderbolt equipped Mac, connect your Symphony I/O or X-Symphony equipped converter, and configure with Logic or Pro Tools.Symphony 64 | ThunderBridge64-Channel Thunderbolt connection for Apogee Symphony I/OApogee’s Symphony 64 | ThunderBridge connects Apogee’s flagship audio interface, Symphony I/O,or X-Symphony equipped Apogee converter to any Thunderbolt™ equipped Mac for true Thunderbolt compatibility and performance. Capable of up to 64 channels of input and output at sample rates up to192kHz, Symphony 64 | ThunderBridge delivers impressive channel counts at unprecedented speedsfor a latency and hassle free recording experience that meets the requirements of the most demanding professional audio I/O applications.Package ContentsThe following items are included in the ThunderBridge box:•Symphony 64 | ThunderBridge•DC Power Supply + IEC Cable•Printed QuickStart Guide•3 meter PC-32 cableIMPORTANT: Thunderbolt cable sold separatelySoftware, firmware and the ThunderBridge User’s Guide are available online only. Please register your product and download the latest installer here:/downloadsSymphony 64 | ThunderBridge TourStatus LEDFront PanelStatus LEDs - These LEDs indicate the status of the corresponding rear panel PC-32 ports, as described below:Port 1 and 2 LEDs flash red - no Apogee interfaces detected - install Symphony software, check PC-32 connection. Port 1 and/or Port 2 LED alternates red to green - the Apogee interface connected to the corresponding port is in an invalid state: verify that interface sample rate matches DAW session rate; verify that interface is clocked correctly. Port 2 off - The port is not enabled. See page 17 for info on connecting multiple audio interfaces.Port 1 and/or Port 2 solidly lit green - Symphony System is correctly configured.DC Power Word Clock OutSymphony PCIPort 1: CH 1-32Thunderbolt PortsSymphony PCIPort 1: CH 1-32Rear PanelDC Power - Connection for the included DC power supply. The unit only powers on when a valid Thunderbolt connection has been made.WC OUT - This output is used only as a diagnostic tool. For clocking audio interfaces, use the word clock output of the interface connected to Port 1 Ch 1-32 or an external master clock such as Apogee Big Ben. Port 1 Ch 1-32 - Connect the first audio interface to this PC-32 port.Port 2 Ch 33-64 - Connect additional audio interfaces to this PC-32 port.Thunderbolt Ports - Connect either Thunderbolt port to the Mac. The remaining port may be used to connect additional Thunderbolt devices. See page 20 for additional details.System RequirementsMac Computer•Computer: Thunderbolt-enabled Mac computer, including MacBook Air, MacBook Pro, Mac mini, and iMac •Memory: 2 GB RAM minimum, 4 GB recommended•Mac OS: 10.7.5 or greater•Connection: Thunderbolt™ (cable sold separately)NOTE: Make sure that your Mac has the Thunderbolt logo. The Mini DisplayPort, featured on many pre-Thunderbolt Macs, is the exact size of a Thunderbolt port but does NOT support Thunderbolt devices. See the difference below:!!Mini Display Port!!ThunderBolt PortCompatible Apogee InterfacesApogee Symphony I/O•Firmware: Release 4.4 or greater•Connection: PC-32X-Symphony equipped Rosetta Series/X Series converter •AD16X, DA16X, Rosetta 800 or Rosetta 200•X-Symphony option card•Firmware: v2.7•Connection: PC-32Connecting to your Mac Install Symphony Software1.Download the latest Symphony installer package here:/downloads2.If you’re using Symphony I/O, you’ll first want to make sure you’re using the most up to date firmware.If you’re using an X-Symphony Equipped X Series/Rosetta Series interface, skip to next page.Once software is downloaded, connect Symphony I/O’s USB port directly to a USB port on your Mac. Double click on the “SymphonyIO Firmware updater” icon and click update once the app opens.3.Connect the included DC power supply to Symphony 64 | Thunderbridge’s DC input and to an AC outlet using the included cable (or using a standard IEC cable for your territory). The DC power supplyaccepts AC from 90-250 volts.4.Connect the Primary Symphony port of yourSymphony I/O, X Series, or Rosetta Series interface to Symphony 64 | ThunderBridge Port 1: CH 1-32 and power on the connected unit. Symphony I/O should be set to Symphony AIM mode. (see usersguide for more info).For info on connecting multiple Apogee interfaces toSymphony 64 | ThunderBridge, see page 17.5.Connect one of Symphony 64 | ThunderBridge’s Thunderbolt ports to your Mac with a Thunderbolt cable - it doesn’t matter which connector is used. See pages 20–21 for details on connecting multipleThunderbolt peripherals.4.Double-click the Symphony I/O Software Installer icon (in the downloaded folder) to launch then follow the steps provided. Restarting your Mac is requiredonce the software installation process is complete.Choosing Symphony 64 | ThunderBridge for Mac Sound I/O Once the Mac has been restarted after installation, a dialog box will prompt you to chooseSymphony 64 | ThunderBridge for Mac sound input and output.Click Yes to use the audio interface connected to Symphony 64 | ThunderBridge Port 1: CH 1-32as the default audio input and output with apps like iTunes, Safari and iMovie.The Status LED will become solid green, indicating that everything is properly connected and you’re ready to go!Connecting Multiple Apogee InterfacesSymphony I/OIf connecting a second Symphony I/O, connect the Primary port of the second unit to Symphony 64 | ThunderBridge Port 2: CH 33-64. Please note that Symphony I/O must always be connected directly to one of the two ports on Symphony 64 | ThunderBridge, so therefore two units is the maximum.AD-16x, DA-16x, Rosetta 800, or Rosetta 200If connecting multiple X-Symphony equipped X Series/Rosetta Series interfaces, please see the list of supported combinations and the corresponding connection diagrams on page 21-33 of the Symphony 64 Usersguide. The supported configurations for Symphony 64 PCIe are the same as with Symphony 64 | ThunderBridge.Connecting Multiple Apogee Interfaces (continued)Symphony 64 | ThunderBridge Port Selection1.Open Audio MIDI Setup application, located in the Applications > Utilities folder of your Mac2.Select Symphony 64 | ThunderBridge from the list of devices on the left3.Click on the Source selection drop down menu and select Port 1-2: 64ch4.Be sure all units are connected/powered on and Restart your MacAfter restart, Any connected unit that’s not connected directly to Port 1: CH 1-32 on Symphony 64 | ThunderBridge will automatically change its clock source to External/Word clock or Loop Sync (if applicable).Connecting Multiple Thunderbolt DevicesThunderbolt supports the connection of up to 6 Thunderbolt devices to each Mac Thunderbolt port. See the connection guidelines below:Connection orderWhen connecting 2-port Thunderbolt devices, there is no required order of connection - simply chain the devices by connecting the Mac to the first device, the first to the second device, and so on until all devices are connected.24531Connecting one-port Thunderbolt devicesOne-port Thunderbolt devices (such as bus powered devices, adaptors and other devices with a single Thunderbolt port) must be connected at the end of the device chain.Connecting Mini DisplayPort monitorsThough Thunderbolt devices can’t be connected to Mini DisplayPort-equipped Mac,one Mini DisplayPort monitor may be connected at the end of the device chain.2431Software SetupUsing the Symphony System with Apple Logic1.Go to the Logic Pro menu and choose:Preferences > Audio.2.In the Core Audio pane of the Device Tab, selectSymphony 64 | ThunderBridge for the Output Device and Input Device.3.Set the I/O Buffer Size to 64. 4.Click Apply Changes at the bottomof the Preferences window.Using the Symphony System with Avid Pro Tools1.Choose Setup > Playback Engine.2.In the Current Engine drop down menu, selectSymphony 64 | ThunderBridge.3.Set the Buffer Size to 64, then click OK.TroubleshootingThe firmware update for Symphony I/O failed:Symphony I/O’s included USB cable must be connected to a USB 2.0 port in order to update the firmware from your Mac. If you have a Mac with only USB 3.0, you will need to use a USB hub in-between the Mac and Symphony I/O. Status LED is green but the device is not recognizedin System Preferences or Audio MIDI Setup•Verify the port selection is set correctly (port 1 if only 1 interface is connected, port 1-2 if more than one)•Restart your MacAdditional Support For more information:• Complete Apogee ThunderBridge User's Guide• Apogee KnowledgeBase and FAQs• Apogee Product Registration• How to contact Apogee Technical SupportVisit: /support/Apogee Electronics Corp. Santa Monica, CA Revision 1.0。
Q UICK I NSTALLATION G UIDESSE-C3632S SSE-C3632SR• 32 x 40Gbps/100Gbps QSFP28 • Power Cords – 2• Rack-mounting kit(two ears\ two L-brackets\six M4 screws\eight M6 screws)• Four adhesive foot pads• RJ-45 to DB-9 serial console cable • This Quick Installation GuideDetailed installation instructions are contained in a User Manual available on the Supermicro website at:/products/accessories/Networking /SSE-C3632S.cfm.Instructions for rack mounting using either the supplied mounting flanges or the supplied rails are included in the manual and summarized below.The SSE-C3632S/SSE-C3632SR can be mounted in a standard 19-inch equipment rack or on a horizontal surface.2. Mount the L-bracket in the rack,using the M6 screws provided in theRack-Mounting Kit.3. Mount the device in the rack, using the M6 screws provided in the Rack-Mounting Kit.Caution : Due to the weight of the switch, installation should be done by two people.4. After installation, go to “Connecting to a Power Source” on this page.5. If installing multiple switches, mount them in the rack, one on top of the other.Desktop or Shelf Mounting1. Attach the four adhesive feet to the bottom of the first switch.2. Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for properairflow.3. After installation, go to “Connecting to a Power Source”.Note : For electrical safety purposes, please pay attention to the following warning notices, printed on the switch unit: Caution : Disconnect the power cord from all power sources tocompletely remove power from the device.Caution : If the installation requires a different power cord thanthe one supplied with the device, make sure you use a powercord displaying the mark of the safety agency that defines theregulations for power cords in your country. The mark is yourassurance that the power cord can be used safely with the device.Instructions for different mounting options are shown below:Rack MountingThis switch can be mounted in a rack using the supplied mountingflanges or with optional mounting rails.To rack-mount devices using the supplied brackets (flanges):1. Attach the ears to the device using the screws provided in the Rack-Mounting Kit.Connect the required devices with the appropriate cables.To connect a device to a power source:1. Insert the Power Supply Unit (PSU) cable plug directly into the ACsocket of a PSU located at the back of the switch. Note : The switch can also be mounted in a rack using a rack shelf or rack “L” brackets.Note : This is a “bare-metal switch which comes without operating software - you will need to obtain the OS from a third party. Make sure the software company has confirmed compatibility with this SupermicroSSE-C3632S/SSE-C3632SR switch and use their instructions for installing their software. Supermicro recommends Cumulus™Linux® from Cumulus Networks™, Inc.• The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet.• This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950. The conditions are onlymaintained if the equipment to which it is connected also operates under SELV conditions.Caution : • Fiber Optic Port Safety. When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on.• This product does not contain any serviceable user parts.• Installation and removal of the unit must be carried out by qualified personnel only.• When connecting this device to a power outlet, connect the field ground lead on the tri-pole power plug to a valid earth ground line to prevent electrical hazards.• This switch uses lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on.• Wear an anti-static wrist strap or take other suitable measures to prevent electrostatic discharge when handling this equipment.• Do not plug a phone jack connector in the RJ-45 port. This may damage this device.• Use only twisted-pair cables with RJ-45 connectors that conform to FCC standards. For more information and safety instruction go to:/manuals/network/Layer_2-3_SDN_Switches.pdfWeight : Net weight: 10.18kg (with 2 PSUs)LEDs:System Fan SFP+ Port 1: Status (Link/Activity)QSFP28 Ports 1~32: Status (Link/Activity)RJ-45 Port: Status (Link/Activity)Size: (W x D x H): 433.8 x 520 x 44 mm (17.07 x 20.47 x 1.73 inches)Temperature : Operating 0°C to 45 °C (32°F to 113°F)Humidity : Operating: 5% to 95% (non-condensing)AC Input : 100-127/200-240 V, 50/60 HzPower Supply:100-127/200-240 VAC, 50/60 Hz,F2B 800W @ 12V/65 A per module (For SSE-C3632S)100-127/200-240 VAC, 50/60 Hz,B2F 800W @ 12V/65 A per module (For SSE-C3632SR)Power Consumption : <650 WattsCE Mark : EN 55022 Class A, EN 55024: 2010, EN 61000-3-2 Class A,EN 61000-3-3.Immunity: EN 55024:2010, IEC 61000-4-2/3/4/5/6/8/11EMI (Class A) : FCC/VCCI/BSMISafety: UL (CSA 22.2 No 60950-1 & UL60950-1)/CB (IEC/EN60950-1)Caution : • Installation and removal of the unit must be carried out by qualified personnel only.• The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.• Do not connect the unit to an A.C. outlet (power supply) without an earth (ground) connection.• The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN 60320/ IEC 320 appliance inlet.CLASS 1LASER DEVICE 2. Plug the other end of the cable into a grounded, 3-pin, AC power source.Note : For use outside North America, you may need to change the AC line cord. You must use a line cord that has been approved for the connector type in your country. 3. Repeat steps 1 and 2 when a second PSU module is installed.Two installed PSU modules operate in a load-sharing mode andprovide 1+1 redundancy.To set up your management connection, the following parameters should be observed:• Console Interface – make sure your console settings are115200-N-8-1 (baud rate 115,200 bps).Ports:32 40Gbps/100Gbps QSFP28 transceiver slots 1 10Gbps SFP+ transceiver slotsNetwork Interface:Ports 1~32: 40Gbps/100Gbps QSFP28 Optical Transceivers:100GBASE-SR4,100GBASE-PSM4QSFP28 Direct Attach Cables can also be used in ports 1~32RJ-45 Port: RJ-45 connector, auto MDI/X 10BASE-T: RJ-45(100-ohm, UTP cable; Category 3 or better) 100BASE-TX: RJ-45(100-ohm, UTP cable; Category 5 or better) 1000BASE-T:RJ-45 (100-ohm, UTP or STP cable; Category 5, 5e or 6)*Maximum Cable Length - 100 m (328 ft)List of Transceivers and Cables :SSE-C3632SSSE-C3632SR E072014-AP-R01150200000828ATransceivers/Cables Vendor Vendor PN100GBASE-SR4Avago AFBR-89CDDZ Finisar FTLC9551REPM TL Luxtera LUX42604Molex1002971101100GBASE-SR4 100GBASE-PSM4100G DAC 1M 30AWG。
RMA物料系統操作程序1.系統架構料件倉料件入庫: 購買或調撥過來的物料, 入庫時必須每筆記錄, 目前僅針對以下物料控管01 / 02 / 03 / 07 / 08 / 10 / 11維修領料紀錄: 維修員領料時必須告知倉管維修板PID及物料數量, 並必須退回廢品, 倉管必須確實記錄, 若廢品未退回, 該維修板將無法再次領料及無法完修料件倉廢品出庫: 維修員退回的廢品由此程序依狀況出庫報廢物料歷史資料搜尋: 可查詢目前物料倉庫存及維修板領料歷史資料, 包含單板領料狀況及搜尋單一物料庫存及領料歷史紀錄2.料件倉料件入庫入庫類別分為調撥, 調整及進貨, 依狀況選擇單號編碼原則與映泰相同, 單號總長14碼, 第三碼以後僅限輸入數字進貨料號編碼原則一樣與映泰統一, 若不確定料號, 可點選右方搜尋料號, 如下一樣關鍵字輸入完畢後按Enter開始搜尋, 搜尋完畢點選所要的料號後按確認鍵結束若數據庫內無所需料號, 可點選新增料號鍵, 手動新增料號, 如下回到上一步, 找到所需料號後, 點選確認, 回到物料入庫畫面, 系統將直接帶入剛剛選取的物料如下圖這時只需輸入入庫數量後按Enter或點選確定完成此料號入庫今日入庫列表顯示今日所有入庫資料, 下方刪除所選料號, 若入錯庫可由此補救3.維修領料紀錄輸入barcode後, 左上方歷史資料裡的領料時間若有資料, 代表這片板曾經領過料, 如上圖, 曾經在5/10中午領過料, 滑鼠雙擊領料時間右方將顯示該次領料內容, 如下圖右上方的刪除領料紀錄可供領料錯誤補救正式領料必須輸入領料人員名稱, 若列表內無該員姓名或代號, 可由左方欄位輸入, 輸入後按Enter跳入料號輸入欄位, 若不知道料號可點選搜尋料號, 搜尋程序與上一小節的入庫相同另外, 不良品替換選項若領料員未繳回廢品, 該選項必須選no, 若領料員未繳回廢品, 將無法再次領料, 該維修板也無法通過完修, 直到倉管將該片板的不良品替換變更為yes若維修板廢品未退回, 再次輸入PID後將跳出如下畫面若要變更不良品替換狀態, 只需在該視窗的“no”上雙擊左鍵, 跳出yes/no的選項, 變更為yes即可, 如下圖回到上一步, 物料輸入完畢後按確定, 完成此物料領料步驟但請注意還沒有完成所有程序….. 確認該維修板所有領取物料紀錄完畢後, 必須點選下方完成鍵待畫面出現領取完畢訊息後才代表物料領用程序完成4.料件倉報廢品出庫報廢出庫程序與入庫基本上完全相同, 僅單號編碼原則有所差異報廢單號總碼數10碼, “RSB-“後為六碼數字5.歷史資料搜尋物料總表物料總表部分, 左方日期區間為必選項目, 下方的料號類別可視需要選擇要搜尋的料號類別單一料號可搜尋特定料號入庫資料若只設定日期區間則會列出該區間內的所有入庫資料日期區間下方的入庫類別/入庫單號/料號類別/單一料號……可視需求添加搜尋條件領料紀錄領料紀錄搜尋除了產品類別及日期區間外, 資料類型也必須選擇才可正常執行搜尋報廢資料日期區間為必填欄位, 單號/料號類別/單一料號…視需求自行增減。
宝利通R M X操作指导书HEN system office room 【HEN16H-HENS2AHENS8Q8-HENH1688】RMX500操作指导书XX项目组201X/X/X目录第1章产品介绍1.1产品概述高品质的实时多媒体通信平台全面支持HD(音频、视频和双流)融合多种不同的通信协议、格式、速率卓越的网络适应机制完全符合工业标准的19英寸硬件平台,安装方便,可独立安装在任何位置,也可安装在标准的机柜中一体化系统平台(语音、视频、数据),高可靠性、高稳定性、使用方便支持双电源备份(可选),安全、可靠创新的智能CP模式,可以在分屏会议中灵活满足各种复杂需求,高清、标清、纯语音客户端可自由互通。
以及支持不同协议、不同速率的会议LPR(Lost Packet Recovery)和动态抖动缓存支持,最新的POLYCOM 专利技术LPR ,抗丢包传输能力极为出色,是目前专业机构评测的最强大的丢包恢复处理技术灵活、快速、安全的网络应用支持,2个千兆口,提供内部路由。
支持跨网组会,防火墙穿透和NAT功能。
可以手动指定TCP和UDP端口灵活、丰富的分屏模式,支持35种不同分屏模式,支持自定义分屏模式和自动分屏模式1.2产品特点支持2台RMX500设备堆叠RMX500可以2台进行堆叠,扩充单台设备的资源能力,支持更多的会议和与会者主从设备需配置相同子网,且连接1000M 网络最多支持2 台设备主从设备需使用相同版本,且从设备能力不能高于主设备纯音频资源不可用从 MCU 的GK、SIP Server 配置无效主和从MCU 剩余资源都小于4 时不能创建会议RMX 500 堆叠后支持最大24 个会议支持2台RMX设备热备份RMX500支持两台设备互为备份,当主设备出现异常情况时,可以在很短的时间内切换到从设备,保证会议的正常进行支持备机IP 地址和服务IP 地址同子网仅支持相同版本设备仅支持相同型号设备不支持双网口多路由备份模式不支持热备下升级设备版本自定义Skin、证书、IVR、路由、SIP Server、观察者和被观察者功能设置不可备部分终端有时不能被正常挂断,需手动挂机主备切换后在系统警告里显示“主备工作正常”信息,10 秒后自动消失系统操作3.1界面介绍会议列表会议列表面板中显示当前设备上所有正在运行的会议及相关信息,包括会议的状态、会议号码、开始时间和结束时间。
卸载:一)MS卸载:1.首先进入home/msi/Accelrys/Materials Studio40/etc/Gateway然后执行./msgateway_control_18888 stop,即停掉gateway网关2.用chkconfig删除与网关相关的文件:/sbin/chkconfig --del msgateway_control_188883.删除/etc/init.d/msgateway_control_18888 的文件:(用根用户删除)rm /etc/init.d/msgateway_control_18888 (感觉第二步和第三步不管用)4.删除与网关有关的所有配置,在Gateway的文件夹下执行./gwdeconfigureall5.用根用户删除所有的MS文件二)License卸载进入home/msi/Accelrys/Licenss_Pack/ Uninstaller,执行./uninstaller1.先加一个用户msi,密码为msi(在根用户下进行)在msi用户下建立一个文件夹tmpiso2.解压iso文件到tmpiso(在根用户下进行)mount -o loop zwt*.iso /home/msi/tmpiso/3.装并行编译hpmpi(在根用户下进行)rm -rf hpmpi/cd msi/tmpiso/UNIX/Linux_x86_64/hpmpi/rpm -ivh hpmpi-2.02.05.01-20070708r.x86_64.rpmls如果仅仅删除hpmpi的文件夹,再安装的时候会提示说已经安装,这时候可以用强制安装:rpm -ivh --force hpmpi-2.03.01.00-20090402r.x86_64.rpm4.进入msi用户进行安装chmod -R 777 UNIX(很多时候安装文件的时候没有权限,用这个命令把权限改过来)cd tmpiso/UNIX./installRunning Materials Studio installer for platform Linux_x86_64...Please specify an absolute destination path [/home/msi/Accelrys/MaterialsStudio43] :Please choose the package you wish to install:1. AmorphousCell Server2. Blends Server3. CASTEP Server4. CCDC Servers (ConQuest, Motif)5. Conformers Server6. DMol3 Server7. DPD Server8. Discover Server9. Equilibria Server10. Forcite Server11. GULP Server12. Gaussian Server13. MesoDyn Server14. Mesotek Server15. Morphology Server16. ONETEP Server17. Polymorph Server18. QMERA Server19. QSAR Models Server20. Reflex+ Server21. Reflex QPA Server22. Reflex Server23. Sorption Server24. Structures Library25. VAMP Server26. EverythingEnter items to install (e.g. 1,2,5) , or Q to quit : 26Starting installation...Install log in /home/msi/Accelrys/MaterialsStudio43/install.logInstalling everything...Checking for dependencies for AmorphousCellServer:6 Checking for dependencies for AmorphousCell: None Checking for dependencies for Licensing:1Checking for dependencies for LicensePack: NoneInitializing InstallShield Wizard........Launching InstallShield Wizard........-------------------------------------------------------------------------------Accelrys License Pack 7.5 - InstallShield WizardWelcome to the InstallShield Wizard for Accelrys License Pack 7.5The InstallShield Wizard will install Accelrys License Pack 7.5 on your computer.To continue, choose Next.Accelrys License Pack 7.5Accelrys Software Inc.Press 1 for Next, 3 to Cancel or 5 to Redisplay [1]-------------------------------------------------------------------------------Accelrys License Pack 7.5 - InstallShield WizardAccelrys License Pack 7.5 Install LocationPlease specify a directory or press Enter to accept the default directory.Destination Directory [/home/msi/Accelrys]Press 1 for Next, 2 for Previous, 3 to Cancel or 5 to Redisplay [1]-------------------------------------------------------------------------------Accelrys License Pack 7.5 - InstallShield WizardSelect the features for "Accelrys License Pack 7.5" you would like to install:Accelrys License Pack 7.5To select/deselect a feature or to view its children, type its number:1. [x] LicensePack2. [ ] Compatibility LicensePackThe Compatibility LicensePack is required for supporting Accelrys software shipped with License Packs 6.x or lower and to support IRIX and Solaris platforms. See License Pack documentation for complete list of Accelrys software supported by this License Pack.Other options:0. Continue installingEnter command [0]Press 1 for Next, 2 for Previous, 3 to Cancel or 5 to Redisplay [1]------------------------------------------------------------------------------- Accelrys License Pack 7.5 - InstallShield WizardAccelrys License Pack 7.5 will be installed in the following location: /home/msi/Accelrys/LicensePackwith the following features:LicensePackfor a total size:153.8 MBPress 1 for Next, 2 for Previous, 3 to Cancel or 5 to Redisplay [1]------------------------------------------------------------------------------- Accelrys License Pack 7.5 - InstallShield WizardInstalling Accelrys License Pack 7.5. Please wait...|-----------|-----------|-----------|------------|0% 25% 50% 75% 100% ||||||||||||||||||||||||||||||||||||||||||||||||||Creating uninstaller...Finalizing the Vital Product Data Registry. Please wait...Configuring License Pack-------------------------------------------------------------------------------Accelrys License Pack 7.5 - InstallShield WizardThe InstallShield Wizard has successfully installed Accelrys License Pack 7.5.Choose Finish to exit the wizard.Press 3 to Finish or 5 to Redisplay [3]Checking for dependencies for SharedSetup:4Checking for dependencies for IntelRuntime: NoneChecking for dependencies for HPMPI:1Do HP-MPI Installation -- MesoDyn server selected.Should HPMPI use SSH? [Y/n]: YConfiguring HP-MPI installationSetting up machines.LINUX file in /home/msi/Accelrys/MaterialsStudio43/share/data Checking for dependencies for GatewayTmp: NonePlease specify the location for temporary files (required for certaincomputational servers), e.g., /tmp or /usr/tmp. Enter ./tmp if you preferto create these files in the directory where the job is being run. Pleasenote that the ./tmp setting could create additional I/O overhead and therebyaffect performance [/tmp] :Checking for dependencies for GatewayScripts: NoneConfiguring environment setupSetting installation path in environment setup script filesChecking for dependencies for Gateway:2Configuring Gateway to use default portConfiguring Gateway for supported queueing systemsChecking for dependencies for PPComponents: NoneChecking for dependencies for Discover: NoneCreating Stand alone AmorphousCell script /home/msi/Accelrys/MaterialsStudio43/AmorphousCell/bin/RunAmorphousCell.shChecking for dependencies for CASTEPServer:7Checking for dependencies for CASTEP: NoneChecking for dependencies for MKL:1Creating Stand alone CASTEP script /home/msi/Accelrys/MaterialsStudio43/CASTEP/bin/RunCASTEP.shChecking for dependencies for DMol3Server:6Checking for dependencies for DMol3: NoneCreating Stand alone DMol3 script/home/msi/Accelrys/MaterialsStudio43/DMol3/bin/RunDMol3.shChecking for dependencies for DPDServer:7Checking for dependencies for DPD: NoneCreating Stand alone DPD script /home/msi/Accelrys/MaterialsStudio43/DPD/bin/RunDPD.sh Checking for dependencies for DiscoverServer:6Creating Stand alone Discover script /home/msi/Accelrys/MaterialsStudio43/Discover/bin/RunDiscover.shChecking for dependencies for EquilibriaServer:7Checking for dependencies for Equilibria: NoneCreating Stand alone Equilibria script /home/msi/Accelrys/MaterialsStudio43/Equilibria/bin/RunEquilibria.shChecking for dependencies for GaussianServer:5Checking for dependencies for Gaussian: NoneYou have chosen to install the Gaussian server but Gaussian seems not to beinstalled on this machine. Before using the Gaussian server please make surethat Gaussian is installed.Press ENTER to continue: Checking for dependencies for MesoDynServer:6Checking for dependencies for MesoDyn: NoneCreating Stand alone MesoDyn script /home/msi/Accelrys/MaterialsStudio43/MesoDyn/bin/RunMesoDyn.shChecking for dependencies for ReflexPlusServer:7Checking for dependencies for MatServer:30Checking for dependencies for xpcom: NoneChecking for dependencies for xpidl: NoneChecking for dependencies for perl: NoneChecking for dependencies for WinCE: NoneChecking for dependencies for MS3rdParty: NoneChecking for dependencies for ApplicationComponents: NoneChecking for dependencies for ApplicationLibraries: NoneChecking for dependencies for Container: NoneChecking for dependencies for ContainerInterfaces: NoneChecking for dependencies for ContainerRootConsumer: NoneChecking for dependencies for ContainerUtils: NoneChecking for dependencies for DataModel: NoneChecking for dependencies for Documents: NoneChecking for dependencies for DocumentsInterfaces: NoneChecking for dependencies for Libraries: NoneChecking for dependencies for SDK: NoneChecking for dependencies for Scripting: NoneChecking for dependencies for ViewersInterfaces: NoneChecking for dependencies for Visualizer: NoneChecking for dependencies for VisualizerInterfaces: NoneChecking for dependencies for QSAR: NoneChecking for dependencies for QSARApplications: NoneChecking for dependencies for Polymer: NoneChecking for dependencies for MSExampleData: NoneChecking for dependencies for Simulations: NoneChecking for dependencies for Analytical: NoneChecking for dependencies for ReflexServer:5Checking for dependencies for PowderIndexing: NoneChecking for dependencies for Structures:1Checking for dependencies for MSStructures: NoneChecking for dependencies for VAMPServer:6Checking for dependencies for VAMP: NoneCreating Stand alone VAMP script /home/msi/Accelrys/MaterialsStudio43/VAMP/bin/RunVAMP.shChecking for dependencies for QMERAServer:7Checking for dependencies for QMERA: NoneChecking for dependencies for GULP: NoneCreating Stand alone QMERA script /home/msi/Accelrys/MaterialsStudio43/QMERA/bin/RunQMERA.shChecking for dependencies for GULPServer:6Creating Stand alone GULP script /home/msi/Accelrys/MaterialsStudio43/GULP/bin/RunGULP.sh Checking for dependencies for ONETEPServer:6Checking for dependencies for ONETEP: NoneCreating Stand alone ONETEP script /home/msi/Accelrys/MaterialsStudio43/ONETEP/bin/RunONETEP.shChecking for dependencies for MesotekServer:6Checking for dependencies for Mesotek: NoneCreating Stand alone Mesotek script /home/msi/Accelrys/MaterialsStudio43/Mesotek/bin/RunMesotek.shChecking for dependencies for BlendsServer:3Checking for dependencies for Docking: NoneChecking for dependencies for ConformerSearchServer:3Checking for dependencies for ForciteServer:2Checking for dependencies for MorphologyServer:3Checking for dependencies for Crystallization: NoneChecking for dependencies for PolymorphServer:3Checking for dependencies for QSARModelsServer:2Checking for dependencies for FastDesc: NoneChecking for dependencies for ReflexQPAServer:3Checking for dependencies for SorptionServer:3Checking for dependencies for CCDCServers:4Checking for dependencies for CCDC: NoneYou have chosen to install the CCDC servers, but neither ConQuest nor Motifappear to be installed. Please make sure that these servers are present beforeattempting to use them.Press ENTER to continue: Creating Stand alone script /home/msi/Accelrys/MaterialsStudio43//bin/Run.shChecking for dependencies for AllMatServer:12Checking for dependencies for Meso: NoneChecking for dependencies for QSARInterfaces: NoneChecking for dependencies for Quantum: NoneIf you would like the Gateway at /home/msi/Accelrys/MaterialsStudio43/etcto be started automatically when the system is restartedyou will need to get your administrator to place a copy of/home/msi/Accelrys/MaterialsStudio43/etc/Gateway/msgateway_control_18888 in /etc/rc.d/init.d/msgateway_control_18888and run:/sbin/chkconfig --add msgateway_control_18888Please refer to the installation instructions for more details.A Materials Studio Gateway provides access to server componentsinstalled on your machine. By default the Gateway is configuredto use minimum security. You can use the Gateway configurationtools after installation to enforce higher levels of security.The servers in this installation will not be available from theMaterials Studio visualizer until the Gateway has been started.If you choose not to start the Gateway now you will need to startit manually after this installation has completed.Please refer to the help text on the CD for instructions on howto start, stop, and customize your Gateway configuration.Would you like to start the Gateway service now? [Y/n]: YStarting gateway...Registering XPCom components; this may take a while...System configuration details for HP-MPIThese checks assume that the default user authentication mechanism is beingused. Your System Administrator may have chosen to use an alternativemechanism. If you find that parallel jobs fail you should consult yourSystem Administrator and ask them to perform appropriate configurationwork. For further details please refer your System Administrator to theinstallation documentation under the info folder on your installation CDChecking remote shell settings for MPIThe HP-MPI installation included as part of this Materials Studio installationrequires that openssh-clients is installed and enabled. openssh-clients is not installedPlease ask your systems administrator to install openssh-clients. Parallel executionof Materials Studio servers will fail if openssh-clients is not installed./etc/hosts.equiv exists. However The HP-MPI installation included aspart of this Materials Studio requires that the uncommented lines in/home/msi/Accelrys/MaterialsStudio43/hosts.eqiv are present.Please ask your systems administrator to check and update /etc/hosts.equivas required.1) Enter temporary license password2) Set connection to license server3) List command line license administration tools99) Finished with license configurationChoose one of the above options: 99Exiting programPress ENTER to continue:Materials Studio installation has completed.5.装licensecd Accelrys/LicensePack/ etc/. lp_profilecd tmpiso/ Crack/lp_install msi.licmsi@linux-fkyc:~/tmpiso/Crack> lp_install msi.lic(这一步可以不要,直接把lic考到ccelrys/LicensePack/Licenses下就可以,MS5.5Licenses用windows下的4.3版本的就可以)This will replace the license file that is currently installed.Do you want to continue?(enter 'y' or 'Y' for YES; any other value for NO)yThe license file has been successfully installed under /home/msi/Accelrys/LicensePack/Licenses/msi.lic.License Pack version: 7.5.0Attempting checkout...Checked out license feature: License_Holder <v7.5> [for Unavailable] (1 copy)Checkout succeeded...Run lp_set_envORcsh: source /home/msi/Accelrys/LicensePack/etc/lp_cshrcsh: . /home/msi/Accelrys/LicensePack/etc/lp_profileto refresh shell license administration environment setup.msi@linux-fkyc:~/tmpiso/Crack> top。