Ultrasonic FlowmeterModel Alsonic-FXGENERALALSONIC-FX series is a fixed mounted,transit-time ultrasonic flowmeter, with clamp-on transducers for non-invasive liquid measurement.Our microprocessor based,user friendly,field programmable flowmeasurement technique allows no interruption of the process flow and has low instalation costs.FEATURES2 line LCD display with flowrate, totalizer & signal condition.Stores up 64 Day/months Totalzier daily valueBatch control functionTransducers for pipe size form 13 to 6000 mm.High accuracy of +/-0.5% of reading.Transducers include magnet devise,for installation on metal pipe withoutmounting belt.Data logger function, include date, totalizer, signal condition.. Etc.Response time less than 1 second.SPECIFICATIONMeasuring Principle:Transit time differenceKeypad:16 Key with tactile actionPipe Size:
1 富士便携式声波流量计安全操作及保养规程
1. 引言
富士便携式声波流量计是一种广泛应用于工业领域的流量测量仪器,它使用声波技术来测量流体的流速。为了确保设备的正常运行和延长其使用寿命,必须严格按照操作规程进行操作和保养。本文将介绍富士便携式声波流量计的安全操作及保养规程。
2. 安全操作规程
2.1 环境要求
在使用富士便携式声波流量计前,请确保工作环境符合以下要求:
• 温度范围:5℃ - 40℃
• 相对湿度范围:10% - 80%
• 无腐蚀性气体存在
• 无明火和易爆性物质存在
2.2 操作步骤
1. 接通电源:将功率线插入相应插座,确保便携式声波流量计可以正常供电。
2. 检查传感器:确保传感器连接牢固,无松动和损坏。
3. 设置参数:根据实际需要,设置相应的参数,如管道直径、流速单位等。 2 4. 安装传感器:将传感器正确安装在待测管道上,并确保传感器与管道接触良好。
5. 打开仪器:按下仪器上的电源按钮,等待仪器启动完成。
6. 进行测量:根据需要选择测量模式,进行流量测量。
7. 结束测量:测量完成后,按下仪器上的停止按钮,停止流量测量。
8. 关闭仪器:长按电源按钮,等待仪器关闭。
2.3 注意事项
• 请确保在操作富士便携式声波流量计前,认真阅读并理解产品的操作手册。
• 在操作过程中,严禁使用力过大的工具或过度扭曲传感器,以免损坏设备。
• 避免将流量计置于潮湿或高温环境中,以免影响设备的性能。
• 避免与尖锐物体接触,防止划伤或损坏设备外壳。
• 若发现设备异常或故障,请立即停止使用,并联系富士公司的维修人员。
3. 保养规程
3.1 清洁
• 定期检查设备表面是否有污垢,如有污垢,请使用柔软湿布擦拭干净。 3 • 请勿使用有机溶剂、强酸或强碱等腐蚀性溶液清洁设备表面,以免损坏外壳。
3.2 存放
• 在停止使用富士便携式声波流量计后,请将设备存放在干燥、通风良好的地方。
FC-80系列超声波流量计中文说明书
- 1 -
目 录
一 概述 .............................................................................................................................................. - 3 -
§1.1 引言 .................................................................................................................................... - 3 -
§1.2 FC-80的特点 ....................................................................................................................... - 3 -
§1.3 工作原理 ............................................................................................................................. - 3 -
§1.6 可选备件 ............................................................................................................................. - 4 -
§1.7产品型号编码规则 ............................................................................................................... - 4 -
便携式超声波流量计操作规程
1. 总则 为确保便携式超声波流量计现场测量流量能够安全、及时、准确,特制定本规 程。
1.1 主题内容 本检维修规程规定了大庆炼化公司内,利用便携式超声波流量计进行现场流量 测量以及比对现场流量计的操作步骤、技术要求、超声波流量计的日常维护、检定 周期、使用注意事项、相应的故障处理等内容。
1.2 适用范围 本规程适用于大庆炼化公司内利用便携式超声波流量计进行现场流量测量的操 作及维护。
1.3 依据
本规程依据《JJG198-1994速度式流量计检定规程》、《JJF(庆炼)14-2001 液 体流量计现场校准方法》编制而成。
2、内容
2. 1 技术要求
2.1.1 对超声波流量计使用环境的技术要求
2.1.1.1 尽量选择没有过多灰尘和腐蚀性气体的使用现场。
2.1.1.2 如果在室外使用,应避免长时间的日光曝晒,防止雨雪等淋湿。
2.1.1.3 被测介质 : 水、污水、海水、酸碱液、汽油、煤油、柴油、酒精等。
2.1.1.4 环境温度:-40~80 C
被测介质温度:标准型-40~80C,介质温度大于 80r使用高温探头。
2.1.1.5 选择合适的测量地点
测量地点应具备足够长的直管段、 满管流体、 气泡较少且安装方便等基本测量条 件。
2.1.2 富士超声波流量计探头型号的选择标准
探头名称型号 适 用 范 围
小口径探头
F L D2 2 小探头(标准)
F L D1 2
大探头
F L G5 1
咼温探头
FLD32
1325 50100 2 0 0 300 400 1000 3000 6000
管道外径(mm)
对于300 mm以上外径的管道推荐采大探头,并使用Z法安装。 2.1.3富士超声波流量计探头安装方式的选择
2.1.3.1探头的安装方式分为 V法和Z法两种。
2.1.3.2 通常情况均使用 V法。