堆栈测试
- 格式:doc
- 大小:54.00 KB
- 文档页数:1
273798294.doc © Source International, 2009, All Rights Reserved
Page 1 of 1
SOURCE INTERNATIONAL
Stacking Test Report (ISTA 2A STANDARD)
ITEM NUMBER PO# TYPE
NEW SAMPLE / PRODUCTION
PRODUCTION DESCRIPTION FACTORY NAME SPEC ISSUE DATE
SPECIFICATION (FILL WHERE ARE APPLICABLE)
PART SPECIFICATIONS CARTON STYLE FLUTE
MASTER CARTON DIMENSION
INNER BOX DIMENSION
FILLER
PROTECTION SHEET
DETERMINATION OF STATIC LOAD COMPRESSION:
ACCORDING TO FORMULA:
L=W X (H-D)/D X F
L =THE LOAD THE PACKAGED-PRODUCT MUST WITHSTAND, IN POUNDS(KG)
W=THE GROSS WEIGHT OF THE INDIVIDUAL PACKAGED-PRODUCT, IN
POUNDS(KG
)
H =THE STACKING HEIGHT, IN INCHES(CM
)
D =THE OVERALL DEPTH OF THE PACKAGED-PRODUCT, IN INCHES(CM)
F = COMPENSATING FACTOR, CONTAINERIZED F=2, NON-CONTAINERIZED F=3.
TEST PROCEDURE:
STEP 1, PLACE THE PACKAGED-PRODUCT ON A SMOOTH, FLAT,
RIGID SURFACE FOLLOWING THE NORMAL
WAREHOUSING PRACTICE, USING PALLETS ABOVE AND BELOW THE PACKAGED-PRODUCT WHEN APPLICABLE.
STEP 2, IF A PALLET IS NOT USED ABOVE THE PACKAGED-PRODUCT;
PLACE A RIGID LOAD SPREADER THAT IS
LARGER THAN THE TOP SURFACE OF THE TEST SPECIMEN ON THE PACKAGED-PRODUCT
.
STEP 3, A
PPLY THE NECESSARY WEIGHT TO BRING THE TOTAL OF THE LOAD SPREADER AND DEAD WEIGHTS UP TO
THE TEST LOAD DETERMINED AND MAINTAIN FOR ONE (1) HOUR, CAUTION SHOULD BE TAKEN TO INSURE THAT THE
LOAD DOES NOT FALL OVER DURING THE TEST.
STEP 4, REMOVE THE DEAD WEIGHT AND INSPECT BOTH THE PACKAGE AND THE PRODUCT WHEN APPLICABLE.
ACCEPTANCE LEVEL:
1) THERE SHOULD BE NO ANY DAMAGE TO PRODUCTS
2)THERE SHOULD BE NO HOLES OR OTHER BREAKAGE OR CHAMFER OR OTHER BREAKAGE TO M
ASTER
CARTON, SLIGHTLY WRINKLE IS ACCEPTABLE.
P
ACKAGED
P
RODUCT
WEIGHT (W)
HEIGHT (H) DEPTH (D)
FACTOR (F) LOADING WEIGHT (L) TEST RESULTS D
ESCRIBED
DETAILS
CONCLUSION SOURCE SIGNATURE FACTORY SIGNATURE D
ATE
PASS / FAIL
Comments:
L