Voltage Transducer LV 100-300For the electronic measurement of voltages : DC, AC, pulsed...,with a galvanic isolation between the primary circuit (high voltage)and the secondary circuit (electronic circuit).Electrical dataVPNPrimary nominal r.m.s. voltage300VVPPrimary voltage, measuring range0 .. ± 450VIPNPrimary nominal r.m.s. current33.33mAR MMeasuring resistanceRM minRM maxwith ± 15 V@ ± 300 V max0170Ω@ ± 450 V max090ΩISNSecondary nominal r.m.s. current50mAK NConversion ratio300 V / 50 mAVCSupply voltage (± 5 %)± 15VICCurrent consumption10 + ISmAVdR.m.s. voltage for AC isolation test, 50 Hz, 1 mn6kVAccuracy - Dynamic performance dataX GOverall Accuracy @ VPN , TA = 25°C± 0.7%εLLinearity< 0.1%TypMaxIOOffset current @ IP = 0, TA = 25°C± 0.2mAIOTThermal drift of IO0°C .. + 70°C± 0.2± 0.3mAtrResponse time @ 90 % of VP max80µsGeneral dataTAAmbient operating temperature0 .. + 70°CTSAmbient storage temperature- 25 .. + 85°CNTurns ratio3000 : 2000PTotal primary power loss10WR 1Primary resistance @ TA = 25°C9kΩR SSecondary coil resistance @ TA = 70°C60ΩmMass850gStandards 1)EN 50178Note :1)A list of corresponding tests is availableFeatures•Closed loop (compensated) voltagetransducer using the Hall effect•Insulated plastic case recognizedaccording to UL 94-V0•Primary resistor R 1 incorporated intothe housing.Advantages•Excellent accuracy•Very good linearity•Low thermal drift•High immunity to externalinterference.Applications•AC variable speed drives and servomotor drives•Static converters for DC motor drives•Uninterruptible Power Supplies(UPS)•Power supplies for weldingapplications.980709/2VPN = 300 V
LEM Components
www.lem.com
Front viewTop viewLeft view
Dimensions LV 100-300
(in mm. 1 mm = 0.0394 inch)
Remarks•IS is positive when VP is applied on terminal +HT.•The primary circuit of the transducer must be linked to theconnections where the voltage has to be measured.•This is a standard model. For different versions (supplyvoltages, turns ratios, unidirectional measurements...),please contact us.Secondary terminalsTerminal+:supply voltage+15 VTerminalM:measureTerminal-:supply voltage-15 VTerminal:ground or earthConnectionLEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.Mechanical characteristics
•
General tolerance± 0.3 mm
•
Fastening2 holes ∅ 6.5 mm
•
Connection of primaryM5 threaded studs
•
Connection of secondaryFaston 6.3 x 0.8 mm
•
Connection to the groundM5 threaded stud
•
Fastening torque2.2 Nm or 1.62 Lb. -Ft.