化工原理课程设计-苯加热器设计
- 格式:doc
- 大小:211.50 KB
- 文档页数:13
太原工业学院
化工原理课程设计
苯加热器设计
系:
班级:
姓名 :
学号 :
完成时间: 年 月 日
列管式换热器设计说明书
2 课程设计任务书
设计一个换热器,将纯苯液体从55℃加热到80℃。纯苯的流量为1.4×104 kg/h。加热介质采用的是具有200 kPa的水蒸气。要求纯苯液体在换热器中的压降不大于30kPa,试设计或选择合适的管壳式换热器,完成该任务。
设计要求
(1)换热器工艺设计计算
(2)换热器工艺流程图
(3)换热器设备结构图
(4)设计说明
列管式换热器设计说明书
3 目录
一、方案简介································································4
二、方案设计································································5
1、确定设计方案·····························································5
2、确定物性数据·····························································5
3、计算总传热系数···························································5
4、工艺结构尺寸·····························································6
5、换热器核算·······························································7
三、设计结果一览表··························································10
四、设计总结 ····························································12
五、参考文献································································13
附图··········································································
列管式换热器设计说明书
4 一、方案简介
1、概述
换热器是化工、石油、食品及其他许多工业部门的通用设备,在生产中占有重要地位,由于生产规模、物料的性质、传热的要求等各不相同,估换热器的类型也是多种多样。
按用途特可分为加热器、冷却器、冷凝器、蒸发器和再沸器等,根据冷、热流体热量交换的原理和方式可分为三大类:混合式、蓄热式、间壁式。
间壁式换热器的特点是冷、热流体被固定壁面间隔开,不想混合,通过间壁进行热量的交换。此类换热器中,以列管式应用最广。本设计任务是利用饱和水蒸气给纯苯加热。利用热传递过程中对流传热原则,制成换热器,以供生产需要。
2、换热器类型
列管式换热器又称为管壳式换热器,是最典型的间壁式换热器,主要分三大类:固定管板式、浮头式、U型管式。
(1) 固定管板式换热器结构简单,成本低,壳程检修和清洗困难,壳程必须是清洁、不易产生垢层和腐蚀的介质。
(2) 浮头式换热器结构较为复杂,成本高,消除了温差应力,是应用较多的一种结构形式。
(3) U型管式换热器结构简单,适用于高温和高压场合,但管内清洗不易,制造困难。
列管式换热器设计说明书
5 二、方案设计
某厂在生产过程中,需将纯苯液体从55℃冷却到80℃。纯苯的流量为1.4×104 kg/h。加热介质采用的三具有200 kPa的水蒸气,要求纯苯液体在换热器中的压降不大于30kPa。试设计或选择合适管壳式换热器。
1.确定设计方案
(1)选择换热器的类型
两流体温度变化情况:
冷流体进口温度55℃,出口温度80℃。
热流体为饱和水蒸气,温度恒为Ts,查表得,200kPa的饱和水蒸气的饱和温度为Ts=120.2℃
该换热器采用饱和水蒸气冷凝放热来加热冷流体,管壁与壳壁温差较大,流体压强不高,初步确定选用固定管板式换热器,考虑到管壁与壳壁温差较大情况,因此,换热器应安装膨胀节,进行热补偿。
(2)管程安排
从流体流经管程或壳程的选择标准来看,纯苯液体有毒,为减少向环境泄露的机会,苯宜走管程;水蒸气较洁净,不会污染壳程,所以饱和蒸汽宜走壳程,以便及时排除冷凝液。综上所述,纯苯液体走管程,饱和水蒸气走壳程。
2、确定物性数据
定性温度:可取流体进口温度的平均值。
管程纯苯的定性温度为:℃==5.6728055T
壳程流体的定性温度为: Ts=120.2℃
根据定性温度,分别查取壳程和管程流体的有关物性数据。
(1)纯苯在67.5℃下的有关物性数据如下:
密度 ρi=830 kg/m3
定压比热容 cpi=1.86 kJ/(kg·℃)
热导率 λi=0.135 W/(m·℃)
粘度 μi=0.00037 Pa·s
(2)饱和水蒸气在120.2℃下的物性数据:
密度 ρ0=1.127 kg/m3
比汽化热 r0=2.205×106 J/kg
热导率 λ0=0.686 W/(m·℃)
粘度 μ0=0.0000133 Pa·s
3.计算总传热系数
(1)热流量
QT=qm1cp1(t2-t1)=14000×1860×(80-55)/3600 =668500 kJ/h =1.808×105 W
(2)冷却水用量 qm2= QT /r0=1.808×105×3600/(2.505×106)=259.880kg/h
(3)平均传热温差 列管式换热器设计说明书
6 ℃7.51552.120802.120ln)552.120()802.120(ln't2121ttttm
(4)初算传热面积
由水蒸气冷凝有机物,有机物黏度为0.00037 Pa·s,查表4-7得
K值大致范围为 500~1200(W/m2 . K)
假设K=600 W/m2 . K,则估算的传热面积为
25m''828.57.5160010808.1tmKQST估
4、工艺结构尺寸
(1)管径和管内流速
选用ф19×2mm较高级冷拔传热管(碳钢),因流体黏度<1,最大流速为2,4 m/s
,所以取管内流速ui=0.5m/s。
(2)管程数和传热管数
依据传热管内径和流速确定单程传热管数
根535.0015.0830360014.3414000ud4q22ovsN
按单管程计算,所需传热管长度为
L=S估/(3.14d0Ns)=5.828∕(3.14×0.019×53)=1.8 m
现取传热管长度L=2m,则该换热器的管程数为
NP=1(管程)
(3)传热管排列和分程方法
采用正三角形排列
取管心距Pt=1.25 d0 =1.25×19=23.75 mm ≈25mm
隔板中心到离其最近一排管中心距离Z=Pt÷2+6=19mm
(4)壳体内径
取02.1db,按三角形排列,根8008.8531.1nC 列管式换热器设计说明书
7 壳体内径为
.6mm22019.212)18(252)1n(PtbDC
圆整可取D=273mm
(5)折流板
采用弓形折流板,取弓形折流板圆缺高度为壳体内径的25%,则切去的圆缺高度为:
h=0.25×273=68.25mm,故可取h=70 mm。
取折流板间距B=0.5D
B=0.5×273=136.5mm,可取B为150 mm。
折流板数
NB=传热管长/折流板间距-1=2000/150-1=12.3,可取12块。
(6)接管
壳程流体进出口接管:取接管内硝基苯流速为 u=1.5 m/s,则接管内径为
m055.0.5114.3127.13600/80.82594u4d1)(V
圆整后可取管内径为60mm
管程流体进出口接管:取接管内冷却水流速 u=2m/s,则接管内径为
m074.0214.38303600/140004d2)(
圆整后可取管内径为80mm
5.换热器核算
(1)传热面积校核
①壳程传热膜系数
4/1e2/332o)dn(725.0tgr
tnldtAQ0
采用试差法估算o值:
a.假设o=10000 W/(m2·℃),
CdQt050086.2532019.014.31000010808.1ln
tw=ts-△t=120.2-2.86=117.34℃
膜温t=(ts+tw)/2=(120.2+117.34)/2=118.8℃
水蒸气在118.8℃时,
密度 ρ=944.1 kg/m3
导热系数 λ0=0.686 W/(m·℃)