easyC v4使用说明4.0
- 格式:ppt
- 大小:4.46 MB
- 文档页数:90


uComplete enterprise management for efficient,integrated building and security management in a single solutionuConsistent use of world-wide open IT standards for configuring, interfacing and displaying makes the system extremely user and installer friendly uProvides even better integration of Bosch and 3rd party systems through OPC complianceuEasily links alarm information to user-defined action-plans and location maps, for a faster and safer reaction from the operatoruModular structure makes it easy to create a security solution which best meets your requirementsThe building management systemThe Building Integration System (BIS) is a flexiblebuilding management system which can be configured to suit the user's specific needs.It contains a huge range of applications and features which enable both the integration and coupling as well as the monitoring and control of all technical building systems.The new generation builds on Bosch's many years of experience in management systems and was considerably influenced by the following market trends:•Increasing complexity of technical building equipment The increasing complexity of technical equipment inside buildings requires a powerful management system which combines the most varied functions (e.g. fire and intrusion alarm systems, access control,video systems and building automation... etc.) in the best possible way. The OPC standard enables BIS to process and share information efficiently with a huge variety of hardware devices and other sources.•Using new technologies and standardsWhile the strict regulations in the field of security technology ensure a high degree of reliability insecurity matters, they hinder the integrated use of new technologies from the IT world. BIS hassucceeded in harnessing the benefits of non-security-based technologies (e.g. OPC, CAD, web) and harmonizing them with the world of security technologies.•Customers want complete solutionsFacility managers and integrators are demanding a single building-management solution that is nevertheless able to integrate all their security subsystems.System overviewThe Building Integration System is a versatile product made up of a basic package plus various optional components (also known as Engines) based on a common software platform. The engines can becombined to tailor building management systems to detailed requirements.These main components are:•Automation Engine •Access Engine •Video Engine •Security Engine* not available in all countriesThese engines are described in greater detail in separate datasheets.FunctionsSystem architectureThe BIS Engines provide fire and intrusion detection,access control, video surveillance plus the monitoring of HVAC and other vital systems.BIS is based on a performance-optimized three-tier architecture especially designed for use in Intranet and Internet environments.Subsystems are connected via the well-established,world-wide OPC standard. This open standard makes it easy to insert BIS into existing OPC-compliant subsystems.4.15.16.n4.n5.n4.1.- 4.n Connection serversOrganizational structure and configurationA number of automatic functions and easy-to-use tools make configuration installer-friendly, saving time and expense.Hierarchical location trees can be created by theimport of existing CAD data containing layers, named views and detector locations. Zooming and panning allow rapid navigation through the building.The user interface is web-server-based using dynamic HTML pages. Default pages for different screenresolutions and formats are included in the installation software, and the default pages can easily be customized using a standard HTML editor.BIS automatically detects the monitor resolution and provides the appropriate user interface.OperationThe system’s main task is to operate as the alarm-monitoring and control center for the various security systems within a site. Its graphical interface isdesigned to help the operator grasp the extent and urgency of an occurrence quickly, and to take prompt and effective action.The heart of the system, the State Machine, monitors all incoming events and operator requests and, if desired, can take actions prescribed by user-defined rules or Associations, thus unburdening the operators.System securityAES encryption between BIS central server andworkstations provides additional security in addition to configurable user-access rights. If PCs within a corporate network are to be used as clientworkstations then enhanced security can be achieved by restricting operators to specific workstations or IP-addresses.Basic packageThe Building Integration System basic packageprovides many features used in common by the various Engines.•Customizable device condition counters to provide an overview of the condition of subsystems across the entire BIS system•Message processing and alarm display•Alarm queue with up to 5000 simultaneous alarmevents and detailed alarm information•Fixed assignment of operators to workstations for higher security•State machine for automated event and alarm handling.•Web-server-based platform allows client workstations to connect to BIS via just the Internet Explorer •Direct support for location maps in standardAutoCAD DWF vector format reduces configurationeffort.•Changes to architecture within a graphic (new walls,moving a door, etc.) can be implemented without changing the BIS configuration, simply import a new plot file.•Automated workflows between operators, with message broadcasting and customizable escalation paths•Huge library of standardized detector icons in standard vector format including color, event and control definitions•Direct control and monitoring of detectors via the context menus of their icons in the location maps •Direct control and monitoring of detectors via the logical tree-structure (e.g. building – floor – room) of a site, with hyperlinks to photos, manuals,instructions•Location tree generated automatically from the "named views" within the AutoCAD graphic•Action management for automatic and manual control into connected subsystems and their peripherals•Device overview for all connected subsystems, and their peripherals (detectors) and internal virtual devices (operator, server, ...) in the form of a tree structure with detailed information about address,status, type, location and notes. Control theperipherals via the context menus of their tree nodes.•Ability to compartmentalize the managed site into autonomous Divisions, and to restrict operators to the control of specific Divisions.•Ability to provide specific information to the operator in the form of free-form “miscellaneous” hypertext documents, including text, bitmaps, video images,etc.•Highly configurable operator access rights for monitoring and control of subsystems and their peripherals•Event log to ensure all events are completely documented (including messages received and actions taken)•Reporting services to quickly create reports from the event log•Linking and embedding of OPC servers from any computer in the network •Online HelpAlarm document packageThis package extends the standard alarm handling of your BIS system with the capability of displayingaction plans and location maps as well as the graphical navigation and the alarm-dependent visualization of layers inside those maps. This ensures optimalguidance to operators especially in stress situations,such as fire or intrusion alarms.Alarm-dependent action plans or workflows provide detailed event-dependent information such asstandard operating procedures, live images, control buttons, etc. to the operator. Simply create and assign one action plan to each possible alarm type in your system, e.g. fire alarm, access denied, technical alarms, etc.With the deletion of an alarm message an unmodifiable snapshot of the displayed action plan is attached to the event log. This ensures accountability by providing a trace of all steps performed by the operator duringthe alarm response.•Location maps are a visualization of premises e.g.floors, areas or rooms, based on the popular AutoCAD vector-graphics format. Detectors and other devices are represented by colored, animated icons thatprovide direct control via their context menus. In the case of an alarm the system zooms automatically to the location in the map where it was triggered.• A location tree provides entry points to the location map and its graphical navigation functions (pan,zoom).•Alarm-dependent layer control allows the display of additional graphical information for specificsituations, e.g. escape routes in case of fire alarms.BIS optional accessoriesThe optional features listed below can be added to the BIS system to meet specific customer requirements.They are usable with all the BIS Engines (Automation,Access, Video and Security Engine).Alarm management packageThis package extends the standard alarm-handling of your BIS system by some additional features:Message distribution allows the definition ofescalation scenarios which are activated automatically when an operator or operator group fails toacknowledge an alarm message within a defined period. BIS will then forward the messageautomatically to the next authorized operator group.The timer feature allows the setup of time schedules which can be used to perform automatic control commands, such as closing a barrier at 8:00 pm, as well as for time-dependent redirection of alarmmessages, e.g. within time period 1 show message tooperator group 1 else to operator group 2.The operator alarm feature allows an operator to trigger an alarm manually from the location tree, for example, if informed by telephone of a dangerous situation. Such manual alarms are processed in the same way as those triggered by a detector: that is, the associated documents are displayed and all steps taken are recorded in the event log.The application launcher allows the invocation of non-BIS applications by the system based upon predefined conditions, e.g. alarms or timers. A typical application of this would be for an automatic, scheduled system backup.Building Integration System in figuresParts includedWhen ordered as Installation Media in Box the box contains:ponents1BIS Installation medium with software and installationmanuals as PDF1Quick installation guide (printed)When downloaded (Version 4.0 and later) the online documentation is contained in the download. Software Maintenance Agreement (SMA)The SMA is a cost-effective way to stay abreast of technical enhancements to the software.Each SMA you purchase entitles you to free upgrades of the corresponding software feature, plus hot fixes and technical support, for a period of one year from the date of purchase.For first-time buyers one year of SMA is included automatically for each item purchased.Technical specificationsMinimum technical requirements for a login or connection serverProcessor 3GHz CPU Dual Core or higher4 GB RAM80 GB of free HD space100 Mbit network card (PCI)USB port (if using the USB installation medium)Graphical adapter with 1280 x 1024, 32 k colors and 256 MB RAM Windows Server 2008 R2,or Windows 7 (32 or 64 Bit, but not Starter/Home Edition),- Microsoft Internet Explorer 9 or 10- Keyboard, mouseSubject to technical changes.Minimum technical requirements for a client computerProcessor 3GHz CPU Dual Core4 GB RAM20 GB of free HD space100 Mbit Ethernet network cardGraphical adapter with 1280 x 1024, 32 k colors and 256 MB RAM non-sharedWindows 7 (32/64 Bit)Microsoft Internet Explorer 9 or 10Keyboard, mouseSubject to technical changes.Ordering informationBIS is available in the following languages:•DE = German•EN = English•ES = Spanish•FR = French•HU = Hungarian•NL = Dutch•PT = Portuguese•RU = Russian•ZH-TW = Traditional Chinese•ZH-CN = Simplified ChineseA BIS basic license is required for when setting up a new systemNote: for versions 3.0 and earlier, a BIS basic package in one of these languages is always required when setting up a new system.Ordering informationBIS 4.0 Installation Media in BoxValid only for BIS V 4.0 and above.Box contains the installation medium for all languages and the Quick Installation Guide.Order number BIS-GEN-B40BOXBIS 4.0 Basic LicenseValid only for BIS V 4.0 and above.Basic license for the Building Integration System (BIS) itself.Order number BIS-BGEN-B40BIS Upgrade from 3.0 to 4.xLicense for an upgrade between the versions specified.Order number BIS-BUPG-30TO40BIS Upgrade from 2.x to 4.xLicense for an upgrade between the versions specified.Order number BIS-BUPG-2XTO40BIS Alarm Management PackageValid only for BIS V 4.0 and above.License bundle containing Message distribution, Timer, Operator alarm, and Application launcher. Order number BIS-FGEN-AMPK40BIS additional 1 Operator ClientValid only for BIS V 4.0 and above.License for one additional concurrent operator. Order number BIS-XGEN-1CLI40BIS additional 1 DivisionValid only for BIS V 4.0 and above.Licenses the addition of an autonomous, named party (aka Division) to your BIS installation.Order number BIS-XGEN-1DIV40BIS Multi-Server Connect per ServerValid only for BIS V 4.0 and above.License for one additional BIS login server within the BIS installationOrder number BIS-FGEN-MSRV40BIS-BVMS ConnectivityValid only for BIS V 4.0 and above.License for the connection between one BIS and one BVMS installationOrder number BIS-FGEN-BVMS40SMA - BIS 4.0 Basic LicenseValid only for BIS V 4.0 and above.The Software Maintenance Agreement for the BIS product specifiedOrder number BIS-SMA-BASSMA - BIS Alarm Management PackageValid only for BIS V 4.0 and above.The Software Maintenance Agreement for the BIS product specifiedOrder number BIS-SMA-AMPKSMA - BIS additional 1 Operator ClientValid only for BIS V 4.0 and above.The Software Maintenance Agreement for the BIS product specifiedOrder number BIS-SMA-1CLISMA - BIS additional 1 DivisionValid only for BIS V 4.0 and above.The Software Maintenance Agreement for the BIS product specifiedOrder number BIS-SMA-1DIVSMA - BIS Multi-Server ConnectValid only for BIS V 4.0 and above.The Software Maintenance Agreement for the BIS product specifiedOrder number BIS-SMA-MSRVSMA - BIS-BVMS ConnectivityValid only for BIS V 4.0 and above.The Software Maintenance Agreement for the BIS product specifiedOrder number BIS-SMA-BVMSRepresented by:Americas:Europe, Middle East, Africa:Asia-Pacific:China:America Latina:Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180***********************.com Bosch Security Systems B.V.P.O. Box 800025617 BA Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 330******************************Robert Bosch (SEA) Pte Ltd, SecuritySystems11 Bishan Street 21Singapore 573943Phone: +65 6571 2808Fax: +65 6571 2699*****************************Bosch (Shanghai) Security Systems Ltd.201 Building, No. 333 Fuquan RoadNorth IBPChangning District, Shanghai200335 ChinaPhone +86 21 22181111Fax: +86 21 22182398Robert Bosch Ltda Security Systems DivisionVia Anhanguera, Km 98CEP 13065-900Campinas, Sao Paulo, BrazilPhone: +55 19 2103 2860Fax: +55 19 2103 2862*****************************© Bosch Security Systems 2014 | Data subject to change without notice 153****2939|en,V3,18.Jul2014。
EasyCoder PD4条码标签打印机用户指南1 EasyCoder PD4描述EasyCoder PD4产品是为中等工业服务的条码打印机,采用热转印和直热式。
内外全金属制造,性能坚固可靠,可在恶劣的工业环境中工作。
EasyCoder PD4有3个版本A 打印机带有3个按键的前端面板,203dpi的打印头和可选的键盘/显示单元和EasyLAN 10外部以太网卡。
B 打印机在前端面板上有为简单设置和监控提供的图形显示和3个按键。
203dpi的打印头,时钟,撕纸传感器。
配件包括剥离器,复绕机,切刀,扩展内存模块,外部键盘/显示单元和EasyLAN 10外部以太网卡。
C 除了拥有300dpi的打印机头外和B一样。
注意:按照此手册如果不另行规定,描述的是有图象显示功能的打印机。
安全警告•在连接打印机前详细阅读此手册•如果边门打开的话移动部件会裸露在外,所以一定在操作打印机前确定边门是在关闭状态。
•不要打开前面和左手盖。
高压危险。
•不要移动底盘。
高压危险。
•不要在打印机电源开着的时候把手指伸入机械装置。
•把打印机安放在能承受大概13KG的平面上。
•不要让打印机淋水。
如果你正在工业环境中使用水龙头,请移开打印机注意防湿防潮•使用清洗卡前仔细阅读包装上的注意事项产品鉴定机器的标签信息附在打印机后部的金属板上,包括种类、型号和系列号,电压和各种认证。
2 安装本章内容介绍如何打开包装和安装EasyCoder PD4打印机,描述打印机不同部件的细节。
包括:打开打印机包装前端部件后金属板部件介质仓部件打印机械装置部件连接打印机应用控制和理解指示灯打开打印机包装在安装打印机之前,检查包装是否有破损或丢失部件::•开箱把打印机拿出•检查打印机是否在运输中被明显损坏。
保留包装盒以备搬动或运输时使用。
•检查打印机后金属板上的标签,上面有电压,产品号和系列号•检查你的选购品是否齐全•检查附件是否齐全。
标配包括:- Intermec EasyCoder PD4 打印机- 电源线- 并口电缆- High edge guide- 空碳带轴- 软件和产品信息CD- 快速应用指南•检查电源线是否合乎本地标准,打印机工作在100 to 240 VAC, 50 to 60 Hz.如果打印机损坏在运输中损坏马上联系运输商。
ThinkDCS设备巡视系统操作手册(上位机部分)目录1系统概述 (2)1.1系统简介 (2)1.2典型系统框图 (2)1.3界面预览 (3)1.4应用范围 (3)2系统安装 (3)3.系统配置及初始化 (4)3.1驱动管理 (5)3.2数据库配置 (6)3.3用户管理 (7)3.4巡视任务模板及线路管理 (10)3.5缺陷库的编辑 (21)3.6报表编辑 (21)3.7报表查看 (24)3.8自动更新 (27)4.系统的运行 (28)4.1任务主站 (28)4.2任务从站的适用场合 (28)4.3状态栏说明 (28)4.4巡视任务 (28)4.4.1巡视任务界面 (28)4.4.2抄表数据管理 (31)4.4.3缺陷数据管理 (32)4.4.4巡视情况表 (33)4.4.5添加临时任务 (33)4.4.6巡视任务查询 (34)4.4.7抄表数据查询 (35)4.4.8运行日志 (35)4.5巡视任务流程 (35)4.6 系统时间 (37)5 异常处理 (38)1系统概述1.1系统简介ThinkDCS设备巡视系统是着眼于电力系统设备巡视而开发的新一代设备巡视系统。
该系统除实现了巡视点签到、巡示设备提示、参数记录、巡视数据处理和查询等基本功能外,着重于拓展系统的数据应用功能以及提高系统的易用性,如:与MIS系统其它相关应用数据库的数据接口、缺陷库的应用、设备运行数据报表定制、WEB查询等功能。
1.2典型系统框图典型巡视系统框图1.3界面预览图11.4应用范围本手册主要介绍了ThinkDCS设备巡视系统上位机软件的使用。
2系统安装2.1系统主要硬件配置需求:●任务主站:intel p4 2GHZ处理器,同级或以上;1G内存;彩显的分辨率1280X1024。
●数据库服务器:推荐采用oracle数据库,硬件配置满足oracle数据库软件运行基本配置即可。
2.2 系统主要基本软件配置需求:microsoft win2K,win xp。