双法兰液位计原理及调试

  • 格式:docx
  • 大小:27.81 KB
  • 文档页数:9

目录

摘 要 ........................................................................................................................ 错误!未定义书签。

Abstract ...................................................................................................................................................... 3

一、概述..................................................................................................................... 错误!未定义书签。

二、原理.................................................................................................................................................... 4

三、外观检查 ............................................................................................................................................ 4

3.1法兰检查 ........................................................................................................................................ 4

3.2变送器检查 .................................................................................................................................... 4

四、验收.................................................................................................................................................... 4

五、调试校验 ............................................................................................................................................ 4

六、重要特点 ............................................................................................................................................ 5

七、液位迁移 ............................................................................................................................................ 5

7.1无迁移 .......................................................................................................................................... 5

7.2负迁移 .......................................................................................................................................... 6

7.3正迁移 .......................................................................................................................................... 7

八、安装.................................................................................................................................................... 7

九、注意事项 ............................................................................................................................................ 8

十、常见故障 ............................................................................................................................................ 8

总 结 ....................................................................................................................................................... 9

摘要

双法兰液位计在工业中起着非常重要的作用,本文通过对具体的工作原理及结构、以及安装调试的步骤进行阐述,结合现场使用情况来进一步说明双法兰液位计的特点,它测量时介质比较单一,不能测混合物、结晶等凝聚物块,膜盒是它最重要的部分,化工生产维修时要保护好膜盒,必要时加装膜盒盖子。

关键词:双法兰液位计;膜盒

Abstract

Double flanged liquid level gauge plays a very important role in the

industry, this article through to the specific working principle and

structure, and elaborates the installation and debugging steps, combined

with the site usage to further illustrate the characteristics of double flange

level gauge, it measured medium is a single, cannot mix, crystallization,

such as condensed piece, bellows is the most important part of it, the

chemical production maintenance to protect the bellows, if necessary, add

membrane lifted the lid.

Key words: double flange level gauge, bellows

一、概述

我公司使用的单、双法兰差压式液位变送器由横河和霍尼韦尔两厂家生产,其中,单法兰差压式液位变送器用在灌区,双法兰差压式液位变送器分别用在气化和合成。本规程只是作为检修单、双法兰差压式液位变送器的通用规程,在检修时还应参考相应的变送器说明书。

二、原理

单、双法兰式差压变送器由差压变送器、毛细管和带密封隔膜的法兰组成。密封隔膜的作用是防止管道中的介质直接进入差压变送器,它与变送器之间是靠注满液体(一般采用硅油)的毛细管连接起来的,当膜片受压后产生微小变形,变形位移或频率通过毛细管的液体传递给变送器,由变送器处理后转换成输出信号。

三、外观检查

3.1 . 法兰检查:检查法兰与设备连接部分的密封是否良好;法兰与毛细管、毛细管与变送器的连接部分及毛细管本身是否有液体泄漏;法兰膜片有无变形、损伤、腐蚀、结垢等不良情况。

3.2.变送器检查:检查变送器外壳有无损伤、腐蚀和其他故障,发现问题及时处理。

四、验收

1.打开变送器外盖,先检查密封圈有无损坏,如果损坏要及时更换;检查电路板及其他元器件是否良好。

2.检查变送器接线情况是否良好。

3.断开电源,卸下接线,进行绝缘电阻检查,用500V兆欧表检查变送器接线端子与外壳间的绝缘电阻,该电阻值应大于20M Ω以上。

五、调试校验

为了保证法兰式差压变送器的测量精度,不能拆开毛细管,所以校验变送器时要与法兰一起校验;在安装前,可用气压模拟信号与HART通讯器进行校验。

零点和量程调整步骤:调整零点和量程输出,使其在允许误差范围内。连续加压,用量程0%,25% ,50% ,75% ,150%的压力进行校验,当压力稳定后记录标准电流表上显示的电流值并做回程误差校验。如果校验误差超过允许误差