pb solving
- 格式:pptx
- 大小:98.11 KB
- 文档页数:4


Ground Fault Circuit Protection• PB-Series• PD-Series (SmartGuard®)ContentsPageAC Branch & Main Ground Fault Protection 1Product Specifications & Ordering Information PB-SeriesGeneral Specifications 2Ordering Scheme4Dimensional Specifications 5Wiring Diagrams 7SMARTGUARD PD-Series General Specifications 8Ordering Scheme10Circuit & T erminal Diagrams11Transforming Customer Needs into Customer SolutionsAt Carling T echnologies, we do much more than manufacture electrical components. We engi-neer powerful solutions. Working closely with your product team, we can tailor switching and cir-cuit protection solutions that meet your application needs — cost effectively.Since our founding in 1920, there are few products we haven’t turned on, fewer industries that haven’t turned to us. With five ISO certified manufacturing locations and technical sales offices worldwide, Carling T echnologies now ranks among the world’s largest privately owned manufac-turers of hydraulic/magnetic circuit breakers, thermal circuit protectors, electrical switches and assemblies, power distribution centers and electronic control systems. In regard to circuit protec-tion, we lead the industry in delivering higher ratings in smaller packages. And what makes all our breakers especially attractive is their superior performance and reliability ––– both hallmarks of Carling T echnologies .Our Ground Fault Circuit Protection products are specifically designed for those applications that could benefit from having overload, short circuit & ground fault protection in a single package.The PB-Series and PD-Series Smartguard can be used to protect several different types of equipment. Applications include:Customer Care CenterFor application assistance, we urge you to consult with our experienced staff in our CustomerCare Center. Our T echnical and Engineering staff has extensive test, research and develop-ment capabilities, and have assisted many customers in solving unique design and application problems with standard or customized products. Please refer to our location listing on the back of this catalog, for contact information for your area.We look forward to working with you.•generators•solar photovotaic systems • marine control panels•de-icing & snowmelting equipment •resistance & impedence heating systems • telecommunications • stage /theatre lighting • office machines • medical equipment • industrial automation • industrial control • UPS Systems •weldersAC Branch & Main Ground Fault ProtectionPB-Series Overload, short circuit and ground fault protection in a single package!The PB-series utilizes the hydraulic magnetic principle which provides precise operation and performance even whenexposed to extremely hot and/or cold application environments. The new PB-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent tripping char-acteristics of a normal circuit breaker.The PB-Series is suitable for:•AC branch ground fault protection - a single circuit solution• AC main ground fault protection for a boat’s entire AC electrical system•Portable generator ground fault protectionElectricalTable A:UL Listed configurations and performance capabilities as Circuit BreakersVOLT S HERTZ(AMP S )UL Listed UL Standard 489Circuit Breakers, Molded Case, (Guide DIVQ, File E129899)UL Standard 1077Supplementary ProtectorsUL Standard 943Class A Ground Fault Circuit Interruptors UL Standard 1053Ground Fault Sensing and Relaying EquipmentAgency CertificationsKey Benefits of the PB-Series:•Increases safety around boats and marinas•Protects against electrical shock hazards in areas near water•Protects against defects in the wires & conductors•Reduces fire and shock hazards from defects in perma-nently installed appliances such as water heaters, battery chargers, lighting fixtures, etc.•Detects lower level ground faults which do not trip ordinary circuit breakers, but can lead to fires, and shock hazards for boating occupantsInnovative FeaturesThese precision mechanisms are temperature stable and are not adversely affected by temperature changes in their operat-ing environment. As such, derating considerations due to tem-perature variations are not normally required, and heat-induced nuisance tripping is avoided.• Overload, short circuit and ground fault protection in asingle package •Handle style actuators and rocker style acuguard”• Wiping Contacts - Mechanical linkage with two-stepactuation – cleans contacts, provides high, positive contact pressure & longer contact life• A trip-free mechanism, a safety feature, makes itimpossible to manually hold the contacts closed during overload or fault conditions.• A common trip linkage between all poles, another safetyfeature, ensures that an overload in one pole will trip all adjacent poles.• Front panel mounting• Integral push-to-test buttonPB-Series –General SpecificationsPB-Series –General SpecificationsStandard Must TripLeakage Current Ratings 5 & 30 milliamps.5± 1mA for UL943, other leakage ratings test to UL1053.For other ratings, consult factory.Trip Time 300 ms Max. @ 100%, 40ms Max.@ 500% of must trip leakage current.T est Button On unit face along side of actuator.Number of Poles 1 - 3 poles, where the third pole is neutral Internal Circuit Config.Series TripWeightApproximately 65 grams/pole.(Approximately 2.32 ounces/pole.)Standard ColorsHousing- Black; Actuator - See Ordering Scheme.MechanicalElectricalPhysicalEndurance10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage.Trip FreeAll PB-Series Circuit Breakers will trip on overload or ground fault,even when Handle is forcibly held in the ON position.Trip IndicationThe operating Handle moves posi-tively to the OFF position when an overload or ground fault causes the breaker to trip.Designed and tested in accordance with requirements of specifi-cation MIL-PRF- 55629 and MIL-STD-202 as follows:Shock Withstands 100 Gs, 6ms, sawtoothwhile carrying rated current per Method 213, T est Condition "I".Ultra-short curves tested @ 90% of rated current.Vibration Withstands 0.060" excursion from10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C,Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current.Moisture Resistance Method 106D, i.e., ten 24-hourcycles @ + 25°C to +65°C, 80-98%RH.Salt Spray Method 101, Condition A (90-95%RH @ 5% NaCl Solution, 96 hrs).Thermal Shock Method 107D, Condition A (Fivecycles @ -55°C to +25°C to +85°C to +25°C).Operating Temperature -35° C to +65° C Corrosion T ested per UL943 FMG T est. 3weeks @ 30°C 75% RH, 100ppb H 2S, 20ppb CI 2, 200ppb NO 2EnvironmentalLeakage To GroundPB-Series –Ordering Scheme2100.1002150.1502200.2002250.2502300.3002350.3502400.4002450.4502500.5002550.5502600.6002650.6502700.7002750.7502800.8002850.8502900.9002950.950410 1.000512 1.250415 1.500517 1.750420 2.000522 2.250425 2.500527 2.750430 3.000435 3.500440 4.000445 4.5004505.000455 5.5004606.000465 6.5004707.0004757.5004808.0004858.5004909.0004959.50061010.00071010.50061111.00071111.50061212.00071212.50061313.00061414.00061515.00061616.00061717.00061818.00062020.00062222.00062424.00062525.00063030.00011Agency Approval8Actuator Color11 AGENCY APPROVAL G UL489 Listed, CSA Certified C UL10779 MOUNTING/BARRIERSMOUNTING STYLEBARRIERS Threaded Insert, 2 per pole A 6-32 X 0.195 inches yes B ISO M3 x 5mmyes7 TERMINAL 213Push-On 0.250 Tab (Q.C.)2Screw 8-32 w/upturned lugs 3Screw 8-32 (Bus Type)4Screw 10-32 w/upturned lugs 5Screw 10-32 (Bus Type)B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs E Screw M4 (Bus Type)H Screw M5 (Bus Type)4Actuator5 FREQUENCY & DELA Y 2260Hz Short 2460Hz Medium 2660Hz Long3 CIRCUIT B Series Trip (Current)2 SYSTEM VOLTAGE / POLES A 120 VAC single phase, one pole B 120/240 VAC single phase, two pole C 120/240 VAC single phase with switched neutral, three pole 6Current Rating3Circuit2SystemVoltage/Poles9Mounting/Barriers7Terminal5Frequency & Delay1SeriesA B A 246202B A GNotes:1 Actuator Code:A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.B: Handle location as viewed from front of breaker:2 pole - left pole 3 pole - center pole 2Screw Terminals are recommended on ratings greater than 20 amps. 3UL & CSA up to 30 amps, but not recommended over 20 amps.4Available with leakage current trip level - Max trip current code E, and agency approval C.56mA per UL943, available with agency approval code G.630mA per UL1053, available with agency approval codes C & G.8 ACTUATOR COLOR & LEGENDI-O ON-OFF DualLegend Color White A B 1Black Black C D 2White Red F G 3White Green H J 4White Blue K L 5White Y ellow M N 6Black Gray P Q 7Black Orange R S 8Black6 CURRENT RATING (AMPERES)–––––PB 10Trip LevelA10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENTA 5 mA (Class A GFCI)4,5,6E 30 mA (ELCB)1 SERIES PBNOTES:Other time delay values available, consult factory.Delay Curves 22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve.All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position.The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse.PB-Series –Dimensional SpecificationsPB-Series –Dimensional Specifications Notes:1All dimensions are in inches [millimeters].2Tolerance ±.020 [.51] unless otherwise specified.InstantaneousShortMediumLong Time Delay CurvesPB-Series –Wiring Diagrams120/240VAC with Switched Neutral120VAC without Switched Neutral120/240VAC without Switched NeutralPD-Series –General SpecificationsSmartGuard ® PD-SeriesOverload, short circuit and equipment ground fault protection in a single package!Today’s high tech equipment demands high tech protection.Our SmartGuard Equipment Leakage Circuit Breaker (ELCB)provides that protection, in one attractive, space-saving pack-age.SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/magnetic circuit breaker, offering customized overload and short circuit protection. In addition, this breaker senses and guards against faults to ground using a state of the art integrated circuit devel-oped by Carling. This new technology detects faults and when a fault occurs, the breaker trips and an LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage. This protection helps prevent serious equipment dam-age and fire.decades ago.UL Recognized UL Standard 1077Component Recognition Program as Equipment Leakage Circuit Interrupter and, Protectors,Supplementary (FTTJ2, File E177510).UL Standard 943T ested as Ground Fault Circuit Interrupters for Equipment Protection.CSA CertifiedComponent Equipment Leakage Current Interrupter with Supplementary Protector, under Class C22.2,No. 144-M91, FIle LR47848-50TUV CertifiedIEC 947-2 and appendix B: Circuit Breakers incorporating Residual Current Protection. Complies with waveform requirements of IEC 1008-1, Type A.Agency CertificationsInnovative FeaturesThese precision mechanisms are temperature stable and are not adversely affected by temperature changes in their oper-ating environment. As such, derating considerations due to temperature variations are not normally required, and heat-induced nuisance tripping is avoided.• Overload, short circuit and ground fault protection in asingle package• Handle style actuators with optional “handleguard”• Wiping Contacts - Mechanical linkage with two-stepactuation – cleans contacts, provides high, positive contact pressure & longer contact life• A trip-free mechanism, a safety feature, makes itimpossible to manually hold the contacts closed during overload or fault conditions.• A common trip linkage between all poles, another safetyfeature, ensures that an overload in one pole will trip all adjacent poles.• Front panel or DIN rail mounting options• “State of the art” integrated circuit developed by Carling • Equipment leakage sensitivity from 10 to 100 milliamps • Integral push-to-test button and LED “tripped” indicator • Immediate reset after fault has been clearedPD-Series –General SpecificationsPD-Series –Ordering Scheme410 1.000512 1.250415 1.500517 1.750420 2.000522 2.250425 2.500527 2.750430 3.000435 3.500440 4.000445 4.500450 5.000455 5.500460 6.000465 6.5004707.0004757.5004808.0004858.5004909.0004959.50061010.00071010.50061111.00071111.50061212.00071212.50061313.00061414.00061515.00061616.00061717.00071717.50061818.00061919.00062020.00062222.00062424.00062525.00063030.00063535.00064040.00065050.0005 CURRENT RATING (AMPERES)9Actuator Color8Actuator10 MOUNTING 31Threaded Insert 6-32 x 0.195 inches 2Threaded Insert ISO M3 x 6.5 mm7 TERMINAL 2Front Connected Box Lug 4 FREQUENCY & DELA Y 2050/60Hz Instantaneous 2250/60Hz Short 2450/60Hz Medium 2650/60Hz Long3 CIRCUIT B Series Trip (Current)1 SERIES PD5Current Rating3Circuit2Voltage/Poles6Equipment Leakage -Trip Current7Terminal4Frequency & Delay1SeriesR B 24650B 2A 1Notes:1Units with a switched or unswitched neutral connection are the same size as a unit withan additional breaker pole (e.g. a 2-pole unit with a switched or unswitched neutral is the same physical size as a 3-pole unit.)Switched neutral poles contain the same overcurrent protection as the other poles.2The leakage currents shown will cause the breaker to trip (must-trip current). The must-hold current is 67% of the must-trip current. 3All breakers are front panel mountable using screw size shown. Breakers may also bemounted on either 35mm x 7.5mm or 35mm x 15mm symmetrical DIN rail.4TUV certifed units must have I-O or Dual legends.11Agency Approval1CPD B 7C 10 D 15 E 30 F 50 G 1008 ACTUATOR A Handle B Handle. with handleguard 9 ACTUATOR COLOR & LEGEND 4ActuatorColor Marking: Marking Color: Color:I-O ON-OFF Dual White A B 1BlackBlack C D 2White Red E F 3White10Mounting11 AGENCY APPROVAL C UL Recognized & CSA Certified U TUV Certified6 EQUIPMENT LEAKAGE - TRIP CURRENT (milliamps)2InstantaneousShort MediumLongTime Delay Curves –––––––PD-Series –Circuit & Terminal DiagramsNotes:1All dimensions are in inches [millimeters].2Tolerance ±.020 [.51] unless otherwise specified.NOTES:Other time delay values available, consult factory.Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% ofrated current and greater within the time limit shown in this curve.Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated currentand greater within the time limit shown in this curve.All Curves: Curve data shown represents breaker response at ambient temper-ature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position.The minimum inrush pulse tolerance handling capability is 12 times the ratedcurrent. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse.Notes:1All dimensions are in inches [millimeters].2Tolerance ±.020 [.51] unless otherwise specified.PD-Series –Circuit & Terminal DiagramsOur extensive web site provides in-depth, detailed information about our productsand capabilities. And with offices aroundthe world, we’re always ready to do business, answer questions and help our customers. Call, fax or e-mail anytime to start working with a company that’s always ON.World-WideCorporate Headquarters Carling Technologies, Inc. 60 Johnson Avenue Plainville, CT 06062860/793-9281FAX: 860/793-9231E-mail:******************** Carling TechnologiesEurope/Middle East/AfricaCarling Technologies Ltd.Devon, EnglandInt + 44 (0)1392-364422FAX: Int + 44 (0)1392-364477E-mail:************************Carling TechnologiesAsia/PacificCarling T echnologies Asia-Pacific Ltd.Kowloon, Hong KongInt + 852-2737-2277FAX: Int + 852-2736-9332E-mail:*********************.hkAdditional Carling Technologies OfficesEast Region Sales Office, CT********************Midwest Region Sales Office, IL********************West Region Sales Office, CA********************GmbH, Germany********************SARL, France,********************Asia-Pacific Ltd., Shanghai, China***************.cnAsia-Pacific Ltd., Japan*********************Pune, India*********************Kaohsiung, Taiwan**********************Warranty PolicyCarling Technologies, Inc. (Seller) warrants that goods sold hereunder shall be free of defects in material and workmanship for one year from date of shipment. In the event of such defects, the Seller’s only obligation shall be the replacement or the cost of the defective goods, themselves, excluding, without limitation, labor costs, which are or may be required in connection with the replacement or reinstallation of the goods. This warranty is the Seller’s sole obligation and excludes all other remedies or warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described herein. This Warranty expressly excludes any and all incidental, special and/or consequential damages of any nature. Seller further disclaims any responsibility for injury to person or damage to or loss of property or value caused by any prod-uct which has been subjected to misuse, negligence, or accident; or misapplied, or modified or repaired by a person or persons not authorized by the Seller or which have been improperly installed.GFCI4_。
[PB]-动态数据窗口〓创建动态数据窗口若要动态创建数据窗口,需要使用函数Create,该函数的语法如下:dw_1.Create(syntax{,errorbuffer})其中,dw_1是数据窗口控件的名称,该数据窗口控件要和新创建的数据窗口对象相关联。
syntax是用来描述创建数据窗口对象的确切语法的字符串。
errorburrer是可选项,用来保存创建数据窗口对象过程中发生的错误信息。
如果不指定该参数,就会在发生错误时显示一个错误信息的提示窗口。
如果创建成功该函数返回1,否则返回-1,如果参数为null则函数返回null。
由于Create函数成功创建数据窗口对象后,要改变dw_1数据窗口控件所关联的数据窗口对象,因此,需要重新为数据窗口设置事务对象(使用函数SetTransObject或者SetTrans)。
获取创建数据窗口的语法有多种方法,可以对相关的SQL语句使用SyntaxFromSQL函数,也可以使用对已经创建好的数据窗口对象使用LibraryExport函数。
因为创建数据窗口的语法比较复杂,即使使用了LibraryExport输出已有数据窗口对象的语法,操作起来也相当费劲。
所以,更为通用的是前面一种方法。
这种方法配合一定的编程技巧,让用户指定要创建的数据窗口对象的SQL语句,使用户有更多的自由和选择。
使用这种方法,肯定用到函数SyntaxFromSQL,它的语法是:transaction.SyntaxFromSQL(SQLselect,presetation,err)其中,transaction是事务对象的名称,该事务对象必须正确地设置了相关参数,并且和数据库建立了联结。
SQLselect是用来创建数据窗口的SQL语句,为String 类型。
presentation是要创建的数据窗口对象的显示风格,为String类型。
简单的格式是:Style(Type=presentationstyle)其中Style和Type都是保留字,presentationstyle的取值有Tabular,Grid,Form,Graph,Group,Label和Nup,其中Tabular是缺省类型。
pb modify用法"pb modify"是一个命令行工具,通常用于修改Protobuf (Protocol Buffers)文件中的消息定义。
在使用"pb modify"命令时,你需要指定要修改的消息名称和要进行的修改操作,例如添加新字段、修改字段类型等。
下面我将从多个角度来解释"pb modify"的用法。
1. 添加新字段:通过"pb modify"命令,你可以向现有的消息定义中添加新的字段。
这可以通过指定字段名称、字段类型和其他必要的属性来完成。
例如,如果你想要向一个名为"User"的消息中添加一个新的"email"字段,你可以使用以下命令:pb modify User --add=email:string.2. 修改字段类型:有时候你可能需要修改现有字段的数据类型,"pb modify"命令也可以帮助你实现这一目的。
例如,如果你需要将一个整数类型的字段改为字符串类型,你可以使用以下命令:pb modify User --type=age:string.3. 删除字段:如果你需要从消息定义中移除某个字段,也可以通过"pb modify"命令来实现。
例如,如果你想要删除"User"消息中的"address"字段,可以使用以下命令:pb modify User --remove=address.4. 修改字段属性:除了修改字段类型外,你还可以使用"pb modify"命令来修改字段的其他属性,比如默认值、是否必填等。
例如,如果你需要将"User"消息中的"age"字段的默认值修改为"18",可以使用以下命令:pb modify User --default=age:18。
pb的ddlb技巧在数据库管理中,DDL(数据定义语言)用于定义数据库的结构,其中包括创建、修改和删除数据库对象。
而PB(PowerBuilder)是一种集成开发环境,用于构建企业级应用程序。
在PB中操作数据库时,可以使用DDL语句来创建、修改和删除数据库对象。
以下是一些PB中使用DDL的技巧:1. 创建表:在PB中,可以使用CREATE TABLE语句来创建数据库表。
可以指定表的名称、列的数据类型、约束等信息。
例如:CREATE TABLE employee (。
emp_id INT PRIMARY KEY,。
emp_name VARCHAR(50),。
emp_salary DECIMAL(10,2)。
);2. 修改表:如果需要修改已存在的表结构,可以使用ALTER TABLE语句。
例如,添加新的列或修改列的数据类型:ALTER TABLE employee.ADD emp_department VARCHAR(50);3. 删除表:如果需要删除已存在的表,可以使用DROP TABLE 语句。
例如:DROP TABLE employee;4. 创建索引:在PB中,可以使用CREATE INDEX语句来创建索引,以提高查询性能。
例如:CREATE INDEX idx_emp_name ON employee (emp_name);5. 删除索引:如果不再需要某个索引,可以使用DROP INDEX 语句来删除它。
例如:DROP INDEX idx_emp_name ON employee;6. 使用事务,在执行DDL语句时,建议使用事务来确保数据的一致性。
可以使用BEGIN TRANSACTION和COMMIT TRANSACTION语句来控制事务的范围。
7. 错误处理,在执行DDL语句时,需要考虑可能出现的错误情况。
可以使用TRY...CATCH块来捕获并处理异常情况,以确保程序的稳定性。
总之,在PB中使用DDL语句需要谨慎对待,确保在操作数据库结构时不会造成数据丢失或不一致。