铜管38冷媒补充计算表
- 格式:docx
- 大小:16.76 KB
- 文档页数:2
管径mmπ半径(去壁厚)米一米管长每米容积(立方米)密度kg/m36.35 3.140.00247510.00001923456.57105℃,1.8MPa 过热蒸汽密度9.52 3.140.0039610.00004924057.77100℃,1.8MPa 过热蒸汽密度12.7 3.140.0055510.00009672059.0595℃,1.8MPa 过热蒸汽密度15.88 3.140.0069410.00015123460.4290℃,1.8MPa 过热蒸汽密度19.05 3.140.00852510.00022820161.8885℃,1.8MPa 过热蒸汽密度22.22 3.140.0099110.00030837363.4580℃,1.8MPa 过热蒸汽密度25.4 3.140.011510.00041526565.1575℃,1.8MPa 过热蒸汽密度28.57 3.140.01308510.00053762267.0170℃,1.8MPa 过热蒸汽密度31.75 3.140.01437510.00064885269.0465℃,1.8MPa 过热蒸汽密度34.92 3.140.0159610.00079982671.360℃,1.8MPa 过热蒸汽密度38.1 3.140.0175510.00096712873.8355℃,1.8MPa 过热蒸汽密度41.28 3.140.0191410.00115030676.7350℃,1.8MPa 过热蒸汽密度75.4645℃,饱和蒸汽密度66.1940℃,饱和蒸汽密度57.9935℃,饱和蒸汽密度50.7130℃,饱和蒸汽密度44.2325℃时饱和蒸汽密度28.57铜管对应气管充氟量密度kg/m3充注量kg0.00053762256.57105℃,1.8MPa 过热蒸汽密度0.0304132810.00053762257.77100℃,1.8MPa 过热蒸汽密度0.0310584280.00053762259.0595℃,1.8MPa 过热蒸汽密度0.0317465840.00053762260.4290℃,1.8MPa 过热蒸汽密度0.0324831260.00053762261.8885℃,1.8MPa 过热蒸汽密度0.0332680550.00053762263.4580℃,1.8MPa 过热蒸汽密度0.0341121210.00053762265.1575℃,1.8MPa 过热蒸汽密度0.0350260790.00053762267.0170℃,1.8MPa 过热蒸汽密度0.0360260560.00053762269.0465℃,1.8MPa 过热蒸汽密度0.0371174290.00053762271.360℃,1.8MPa 过热蒸汽密度0.0383324550.00053762273.8355℃,1.8MPa 过热蒸汽密度0.0396926390.00053762276.7350℃,1.8MPa 过热蒸汽密度0.0412517430.00053762275.4645℃,饱和蒸汽密度0.0405689630.00053762266.1940℃,饱和蒸汽密度0.0355852060.00053762257.9935℃,饱和蒸汽密度0.0311767050.00053762250.7130℃,饱和蒸汽密度0.0272628160.00053762244.2325℃时饱和蒸汽密度0.0237790250.00004924059.0595℃,1.8MPa 过热蒸汽密度0.0029076350.00004924060.4290℃,1.8MPa 过热蒸汽密度0.0029750940.00004924061.8885℃,1.8MPa 过热蒸汽密度0.0030469850.00004924063.4580℃,1.8MPa 过热蒸汽密度0.0031242920.00004924065.1575℃,1.8MPa 过热蒸汽密度0.0032080010.00004924067.0170℃,1.8MPa 过热蒸汽密度0.0032995870.00004924069.0465℃,1.8MPa 过热蒸汽密度0.0033995450.00004924071.360℃,1.8MPa 过热蒸汽密度0.0035108280.00004924073.8355℃,1.8MPa 过热蒸汽密度0.0036354060.00004924076.7350℃,1.8MPa 过热蒸汽密度0.0037782020.00004924075.4645℃,饱和蒸汽密度0.0037156670.00004924066.1940℃,饱和蒸汽密度0.003259210.00004924057.9935℃,饱和蒸汽密度0.0028554410.00004924050.7130℃,饱和蒸汽密度0.0024969720.00004924044.2325℃时饱和蒸汽密度0.002177895 12.7铜管对应气管充氟量密度kg/m3充注量kg0.00009672056.57105℃,1.8MPa 过热蒸汽密度0.0054714420.00009672057.77100℃,1.8MPa 过热蒸汽密度0.0055875060.00009672059.0595℃,1.8MPa 过热蒸汽密度0.0057113070.00009672060.4290℃,1.8MPa 过热蒸汽密度0.0058438130.00009672061.8885℃,1.8MPa 过热蒸汽密度0.0059850240.00009672063.4580℃,1.8MPa 过热蒸汽密度0.0061368740.00009672065.1575℃,1.8MPa 过热蒸汽密度0.0063012980.00009672067.0170℃,1.8MPa 过热蒸汽密度0.0064811970.00009672069.0465℃,1.8MPa 过热蒸汽密度0.0066775380.00009672071.360℃,1.8MPa 过热蒸汽密度0.0068961250.00009672073.8355℃,1.8MPa 过热蒸汽密度0.0071408270.00009672076.7350℃,1.8MPa 过热蒸汽密度0.0074213140.00009672075.4645℃,饱和蒸汽密度0.007298480.00009672066.1940℃,饱和蒸汽密度0.0064018870.00009672057.9935℃,饱和蒸汽密度0.0056087840.00009672050.7130℃,饱和蒸汽密度0.0049046640.00009672044.2325℃时饱和蒸汽密度0.0042779190.00041526559.0595℃,1.8MPa 过热蒸汽密度0.0245213980.00041526560.4290℃,1.8MPa 过热蒸汽密度0.0250903110.00041526561.8885℃,1.8MPa 过热蒸汽密度0.0256965980.00041526563.4580℃,1.8MPa 过热蒸汽密度0.0263485640.00041526565.1575℃,1.8MPa 过热蒸汽密度0.0270545150.00041526567.0170℃,1.8MPa 过热蒸汽密度0.0278269080.00041526569.0465℃,1.8MPa 过热蒸汽密度0.0286698960.00041526571.360℃,1.8MPa 过热蒸汽密度0.0296083950.00041526573.8355℃,1.8MPa 过热蒸汽密度0.0306590150.00041526576.7350℃,1.8MPa 过热蒸汽密度0.0318632830.00041526575.4645℃,饱和蒸汽密度0.0313358970.00041526566.1940℃,饱和蒸汽密度0.027486390.00041526557.9935℃,饱和蒸汽密度0.0240812170.00041526550.7130℃,饱和蒸汽密度0.0210580880.00041526544.2325℃时饱和蒸汽密度0.018367171 19.05铜管对应气管充氟量密度kg/m3充注量kg0.00022820156.57105℃,1.8MPa 过热蒸汽密度0.0129093570.00022820157.77100℃,1.8MPa 过热蒸汽密度0.0131831980.00022820159.0595℃,1.8MPa 过热蒸汽密度0.0134752960.00022820160.4290℃,1.8MPa 过热蒸汽密度0.0137879320.00022820161.8885℃,1.8MPa 过热蒸汽密度0.0141211060.00022820163.4580℃,1.8MPa 过热蒸汽密度0.0144793830.00022820165.1575℃,1.8MPa 过热蒸汽密度0.0148673250.00022820167.0170℃,1.8MPa 过热蒸汽密度0.015291780.00022820169.0465℃,1.8MPa 过热蒸汽密度0.0157550290.00022820171.360℃,1.8MPa 过热蒸汽密度0.0162707640.00022820173.8355℃,1.8MPa 过热蒸汽密度0.0168481140.00022820176.7350℃,1.8MPa 过热蒸汽密度0.0175098980.00022820175.4645℃,饱和蒸汽密度0.0172200820.00022820166.1940℃,饱和蒸汽密度0.0151046550.00022820157.9935℃,饱和蒸汽密度0.0132334030.00022820150.7130℃,饱和蒸汽密度0.0115720960.00022820144.2325℃时饱和蒸汽密度0.0100933513.5.6追加制冷剂的计算根据连接配管的尺寸而非室内机的型号来计算配管的追加冲注量。
铜管38冷媒补充计算表摘要:一、引言二、铜管38 冷媒补充计算表的概述1.什么是铜管38 冷媒补充计算表2.铜管38 冷媒补充计算表的作用三、铜管38 冷媒补充计算表的使用方法1.确定所需参数2.计算补充冷媒量3.检查结果四、铜管38 冷媒补充计算表的应用领域1.空调系统维修2.空调安装3.其他相关领域五、总结正文:一、引言在我国制冷空调行业中,铜管38 冷媒补充计算表是一个非常重要的工具,对于空调系统的设计、维修以及安装等方面具有重要的指导意义。
本文将对铜管38 冷媒补充计算表进行详细介绍,包括其定义、作用以及使用方法等内容。
二、铜管38 冷媒补充计算表的概述1.什么是铜管38 冷媒补充计算表铜管38 冷媒补充计算表是一种用于计算空调系统中冷媒(制冷剂)补充量的工具,主要针对铜管38 空调系统设计。
该计算表能够根据空调系统的实际运行情况,精确计算出需要补充的冷媒量,以确保空调系统能够正常运行。
2.铜管38 冷媒补充计算表的作用铜管38 冷媒补充计算表的主要作用有以下几点:(1)提高空调系统的运行效率:通过精确计算冷媒补充量,避免过量或不足的冷媒对空调系统运行效率的影响。
(2)节能:精确控制冷媒量,降低空调系统的能耗,实现节能目标。
(3)保护环境:合理控制冷媒的使用量,有助于减少对臭氧层的破坏,保护环境。
三、铜管38 冷媒补充计算表的使用方法1.确定所需参数使用铜管38 冷媒补充计算表前,需要先确定以下参数:(1)空调系统的类型及规格(2)当前系统中的冷媒量(3)系统的工作压力和温度2.计算补充冷媒量根据所提供的参数,在铜管38 冷媒补充计算表中查找对应的数值,计算出需要补充的冷媒量。
3.检查结果在计算出补充冷媒量后,需要检查计算结果是否合理。
如发现异常,应重新检查参数的准确性,或寻求专业人士的帮助。
四、铜管38 冷媒补充计算表的应用领域1.空调系统维修在空调系统维修过程中,铜管38 冷媒补充计算表可以帮助维修人员快速准确地确定需要补充的冷媒量,提高维修效率。
铜管38冷媒补充计算表摘要:1.铜管38 冷媒补充计算表的概述2.冷媒补充计算的相关知识3.铜管38 冷媒补充计算表的应用实例4.使用铜管38 冷媒补充计算表的注意事项正文:一、铜管38 冷媒补充计算表的概述铜管38 冷媒补充计算表是一种针对制冷系统中冷媒补充量的计算工具,它可以帮助工程师或技术人员快速、准确地确定冷媒的补充量,以保证制冷系统的正常运行。
在制冷系统中,冷媒的补充是非常重要的,因为冷媒的缺失或不足会导致制冷效果不佳,甚至使制冷系统失效。
二、冷媒补充计算的相关知识冷媒补充计算需要考虑以下几个因素:1.制冷系统的热负荷:热负荷的大小决定了制冷系统需要多少冷媒来吸收热量,从而实现制冷。
2.制冷系统的工作温度:工作温度决定了冷媒的蒸发温度和冷凝温度,进而影响冷媒的流量和补充量。
3.制冷系统的热效率:热效率越高,需要的冷媒补充量就越少。
三、铜管38 冷媒补充计算表的应用实例以一个制冷量为100kW 的制冷系统为例,假设热负荷为500kcal/h,工作温度为-10℃,热效率为30%,则可以通过铜管38 冷媒补充计算表来确定需要的冷媒补充量。
首先,根据热负荷和热效率,可以计算出制冷系统需要的冷媒流量为:500kcal/h ÷ 30% = 1666.67kJ/h。
然后,根据工作温度,可以查表得到冷媒的蒸发温度和冷凝温度,进而确定冷媒的比热(h)。
最后,根据冷媒的比热和流量,可以计算出需要的冷媒补充量为:1666.67kJ/h × h。
四、使用铜管38 冷媒补充计算表的注意事项使用铜管38 冷媒补充计算表时,需要注意以下几点:1.确保输入的数据准确无误,否则计算结果可能会出现偏差。
2.根据实际情况选择合适的冷媒类型,不同类型的冷媒其物理性质和热力学性能可能会有所不同。
3.在计算过程中,要充分考虑到制冷系统的工作环境、设备状态等因素,以保证计算结果的可靠性。
铜管38冷媒补充计算表
(原创实用版)
目录
1.铜管 38 冷媒补充计算表概述
2.冷媒补充的必要性
3.铜管 38 冷媒补充计算的具体方法
4.冷媒补充的安全注意事项
5.结论
正文
一、铜管 38 冷媒补充计算表概述
铜管 38 冷媒补充计算表是一个针对空调制冷系统中冷媒补充的计
算工具,它可以帮助工程师或技术人员快速、准确地计算出在特定条件下
需要补充的冷媒量。
铜管 38 是指空调系统中的冷媒管道直径为 38 毫米,这是一种常见的管道规格。
二、冷媒补充的必要性
在空调制冷系统的运行过程中,由于各种原因,如泄漏、蒸发等,冷
媒的数量可能会减少。
如果不及时补充,会导致制冷效果降低,甚至无法正常制冷。
因此,冷媒补充是保证空调制冷系统正常运行的重要环节。
三、铜管 38 冷媒补充计算的具体方法
铜管 38 冷媒补充计算表主要根据以下参数进行计算:制冷系统的热负荷、制冷剂的种类和温度、管道的长度和直径等。
计算时,需要先确定
制冷系统的热负荷,然后根据制冷剂的种类和温度查表得到相应的制冷剂
流量,再根据管道的长度和直径计算出流速,最后根据流速和热负荷计算
出需要补充的冷媒量。
四、冷媒补充的安全注意事项
1.在补充冷媒之前,应先检查制冷系统的泄漏原因,并进行修复,以防止补充的冷媒再次泄漏。
2.补充冷媒时,应选择与原系统中冷媒相同的品种和型号,以保证系统的正常运行。
3.补充冷媒前,应先关闭制冷系统的压缩机和膨胀阀,避免在补充过程中发生意外。
4.补充冷媒时,应注意安全,避免冷媒接触到皮肤或眼睛,以免造成伤害。
五、结论
铜管 38 冷媒补充计算表是空调制冷系统维护中必不可少的工具,它能帮助技术人员准确地计算出需要补充的冷媒量,保证制冷系统的正常运行。