Features and Benefits•Ergonomic design and ultra light weight for easy one person operation•Detachable digital manometer for use in other applications •Use with Pitot, air flow, temperature, velocity matrix, or relative humidity probes•Back pressure compensation •Bio-Safety hood kit availableManometerModel EBT720The EBT720 is one of the most advanced, versatile, and easy to use manometers on the market today. Auto-zeroing allows you to make measurements throughout the day. The velocity matrix accessory is useful in measuring face velocity through filters,coils, and other specialized spaces.Features and Benefits•Accurately measures pressure, velocity (Pitot), and flow •Large, easy to read display•Data logging and downloading software included •Automatic density correctionRugged. Reliable. Professional.Air Volume InstrumentsModel EBT721Applications•HVAC commissioning •Clean room certification •Troubleshooting HVAC systems •Testing and balancing HVAC systemsOptional Accessories for EBT720 AND EBT721•Pitot tubes•16-point velocity matrix with telescoping handle •Air flow probe •Temperature probe •Temperature/humidity probe •Multiple hood sizes available •Bio-safety cabinet hood kitModel EBT720(Shown with optional accessories)Model EBT721(Shown with optional accessories)Specifications Models EBT720 and EBT721Velocity RangePitot probes25 to 15,500 ft/min (0.125 to 78 m/s)Air flow probe25 to 15,500 ft/min (0.125 to 78 m/s)Velocity matrix25 to 5,000 ft/min (0.125 to 25 m/s)Accuracy±3% of reading ±7 ft/min (±0.04 m/s) atvelocities >50 ft/min (>0.25 m/s)Units ft/min, m/sResolution 1 ft/min (0.01 m/s)PressureDifferential pressure±15 in. H2O (±3735 Pa);150 in. H2O (37.5 kPa),maximum safe operating pressureAbsolute pressure15 to 40 in. Hg (356 to 1016 mm Hg) Accuracy±2% of reading ±0.001 in. H2O (±0.25 Pa)static and differential; ±2% of reading absolute Units in. H2O, in. Hg, Pa, hPa, kPa, mm Hg,cm Hg, mm H2O, cm H2O,Resolution0.00001 in. H2O (0.001 Pa) static anddifferential; 0.01 in. Hg (1 mm Hg) absolute VolumeRange25 to 2,500 ft3/min (42 to 4250 m3/h) capture hood Accuracy±3% of reading ±7 ft3/min (±12 m3/h) atflows >50 ft3/min (>85 m3/h)Units ft3/min, m3/h, m3/min, l/sResolution 1 ft3/min (1 m3/h)RHRange0 to 95% RH temperature/RH probeAccuracy±3% RHResolution0.1% RHTemperatureSensor in base40 to 140°F (4.4 to 60°C)Temperature probe-40 to 250°F (-40 to 121°C)Temperature/RH probe14 to 140°F (-10 to 60°C)Accuracy±0.5°F (±0.3°C) from 32 to 160°F (0 to 71°C) Units°F, °CResolution0.1°F (0.1°C)Instrument Temperature RangeOperating40 to 140°F (4.4 to 60°C)Storage-4 to 160°F (-20 to71°C)Statisticsmin, max, average up to 1000 readingsData Storage1,000 readings, time and date stamped Logging IntervalUser selectableResponse Time2 to 8 secondsDisplay6 digit, 0.75 in. (19 mm) character height, multi-line, sectored, multiple symbolic icons, high-contrast backlit LCD Dimensions (manometer only)7.4 in. x 4.5 in. x 2.3 in. (18.8 cm x 11.4 cm x 5.8 cm) Pressure Connection1/4in. (6.35 mm) OD straight ports for use with 3/16in. (4.76 mm) ID flexible tubingWeight with BatteriesEBT720 17 oz (0.5 kg)EBT721 7.4 lb (3.4 kg)Power RequirementsFour AA-size cells or AC adapterContact your local Alnor Distributor or visit our website for more detailed specifications. P/N 2980561 Rev D Copyright © 2010 by TSI Incorporated Printed in U.S.A.。
Amico Diagnostic Incorporated | 122 East Beaver Creek Road, Richmond Hill, ON L4B 1G6, Canada Toll Free Phone: 1.877.264.2697 | Tel: 905.763.7778 | Fax: 905.763.8587Email:*********************| Installation to WallStep 1Securely attach wall bracket to flat surface at desired height usingincluded screws and wall anchors.Step 2Attach clock gauge to wall bracket. Tighten securely using screwdriver.Step 3Securely attach cuff basket to flat surface using included screws andwall anchors. Basket can be mounted below or beside the aneroid,depending on end-user preference and space availability.Step 4Pressure fit “female” end of BP Cuff & Bulb assembly over the“male” nipple just behind the aneroid face.Direct Mount Aneroid and Cuff BasketInstallation Quick Start GuideADX-INSTAL-QK-REF-ANRD-MOUNT-CUFF-BSKT 07.23.2020Medical Facility ResponsibilityPreventive maintenance checks must be performed regularly to maintain the quality and performance of this product. Any parts that may be broken, missing, worn, distorted or contaminated in any way should not be used and all affected parts should be replaced immediately. Should the necessity of any repair be suspected; please contact your local Amico distributor.Installation Tools#2 Phillips ScrewdriverDrill1/8" Drill BitInstallation Tools1.Direct-Mount Aneroid2.4x #8x1” Sheet Metal Screws3.4x Plastic Wall Anchors4.Blood Pressure Cuff Basket5.3x #8x1” Sheet Metal Screws6.3x #6-8 Plastic Wall Anchors7.1x Plastic Clip for 1/4” Wire8.Blood Pressure Cuff & Bulb, with Coil BB。
BA100电子气压计钓鱼爱好者都知道大气压力对鱼的活性有影响,主要是高气压情况下,水里面的溶氧量就高,鱼儿的活性高胃口就好;反之,鱼的活性很低,胃口就差。
如果了解气压变化情况,对于提高鱼获几率将会有很大帮助。
您想知道在什么气压情况下去钓鱼吗? 该款电子气压计就是为钓鱼爱好者提高鱼获几率而设计的一款产品。
该产品主要功能有气压测量、高度测量、温度测量、6组钓点气压记录、钓点水深记录、钓点气压校正、适合钓鱼气压报警功能设置、天气预报、24小时气压变化图表显示、历史3天数据记录、时间日期、LED 蓝色背光等。
特点:1.一键校正钓点气压功能,让您无论何时何地都可以掌握钓点准确的气压信息,为出钓之前提供依据。
说明:气压变化及天气变化在一定区域范围内可以默认为线性变化(约100-200公里范围)。
基于此,该项功能可正常使用。
例如,在钓点1位置(西丽水库)保存该位置气压值1006.2hpa;回到家中(20楼)气压999.3hpa,校正钓点1气压值,把家里的气压变化与钓点气压形成联动关系。
当家里气压变化2hpa 时(即1001.3hpa),钓点1对应变化2hpa(即1008.2hpa);同时形成24小时气压变化图,为出钓之前提供准确的气压参考依据。
可跟踪6个钓点气压。
(具体参考1-3步骤)2.开放钓点气压数据记录功能,您可根据需要记录钓点的水深,气压值等。
为您的下一次出钓提供参考。
说明:例如,再钓点1,气压1012hpa,水深2米,钓得一重达5斤的大物。
把该气压值及钓位水深2米保存,以备下次在该钓位作参考。
(见2、3项步骤)。
3. 24小时气压变化图,气压变化趋势箭头指示,让您时刻掌握气压变化情况,适时调整钓位水深,提高鱼获几率。
说明:在夏天钓鱼,一天里面的气压变化往往很剧烈,反应在鱼身上就是表层活动的鱼有时会浮头,底层活动的鱼也会跑到水的中上层活动。
这个时候如果还采用钓底的方式钓鱼,往往会空手而归,如果适时调整钓位的水深,可能会有意想不到的收获。
多功能气压计使用说明书V1.0目录1. 产品介绍31.1. 产品特点31.2. 产品规格31.3. 气压计硬件的使用42. 气压计软件“多功能气压计”的使用42.1. 软件“多功能气压计”的介绍42.2. 软件“多功能气压计”的安装42.3. 启动软件42.4. 重新连接蓝牙52.5. 修改多功能气压计的蓝牙配对密码62.6. GPS功能的开启和关闭设置62.7. 主界面功能的使用62.7.1. 气压,指南针功能72.7.2. 登山功能72.7.3. 钓鱼功能92.7.4. 设置122.8. 关于公司和软件界面143. 使用注意事项154. 常见问题的解答15免责声明161.产品介绍1.1. 产品特点➢与安卓智能手机配合使用,体积小,方便携带使用➢MiniUSB 5V电源即为气压计供电也做为锂电池的充电电源➢具有气压、指南针功能:显示当前方位、实时气压、温度、海拔、时间和经纬➢具有登山功能:登山高度、GPS测距、查看数据➢具有钓鱼功能:钓点预测、实地评分、保存钓点、查看钓点、钓鱼知识➢蓝牙在1分钟内无连接时自动断开蓝牙电源,气压计进入休眠状态➢气压计进入休眠状态,每隔一段时间可自动记录保存当前气压、温度➢可设置手机自动记录间隔时间、设置气压计自动记录间隔时间、校正海拔1.2. 产品规格产品型号:WTZ809A工作电压:DC3.7V ~ DV5V待机电流:15uA蓝牙未连接时电流: 14mA ~ 55mA蓝牙连接时电流: 28mA ~ 32mA气压计量程:10hpa ~ 1100hpa气压值精度:≤3hpa支持蓝牙:蓝牙2.0及以上,有效距离3M内使用环境:相对湿度小于95%产品大小:长*宽*高 = 44.08mm*29mm*13.18mm气压计面板介绍编号功能状态状态意义1 MiniUSB接口断开USB电源断开接上为气压计供电同时给电池充电2 USB电源指示灯灭USB电源断开亮USB电源接上,电池充电3 工作电源开关Off 气压计电源断开On 气压计电源接通4 蓝牙连接指示灯灭气压计进入休眠状态或气压计不工作闪烁蓝牙未连接上常亮蓝牙连接上5 气压计工作指示灯灭气压计进入休眠状态或气压计不工作每秒闪烁一次气压计正常工作快速闪烁气压计电池电量不足6 蓝牙按键工作状态下短按气压计进入休眠状态并记录一次数据休眠状态下短按记录一次气压计数据工作状态下长按气压计进入休眠状态并记录一次数据休眠状态下长按气压计进入工作状态1.3. 气压计硬件的使用将工作电源开关拨向on状态,当工作指示灯和蓝牙连接指示灯亮时,便可与智能手机配合使用;若工作指示灯和蓝牙连接指示灯都不亮,长按蓝牙按键,直到蓝牙指示灯闪烁后放开按键,便可与安卓智能手机配合使用相关功能。
· 665 Pine Avenue, Saint-Lambert, QC, J4P 2P4 CANADA · Phone 1-450-465-1113 · Fax 1-450-465-1938 ·****************· · 10, avenue Eiffel, 77220 Gretz-Armainvilliers, FRANCE · Phone +33-1-64-06-40-80 · Fax +33-1-64-06-40-26 ·***************· www.telemac.fr · Via Pobiette 11, CH-6928 Manno, SWITZERLAND · Phone+41 91 610 1800 · Fax +41 91 610 1801 ·******************· www.smartec.chTEST PROCEDURE The probe is placed at the test depth in a pre-drilled borehole obtained by a method adapted to the soilconditions: augering, rotation with drag bit andbentonite, shelby tube driving, etc. In granular soils below the water table, the probe can be drivendirectly within a slotted casing.The test is run either with a constant rate ofdeformation,by using a uniform rate of rotation of the actuator, or with equal increments of pressure as forthe Menard pressuremeter test .TEST RESULTS An in-situ stress-strain curve is obtained by plottingthe injected volume against pressure.The limit pressure PL is the pressure at which failure occurs, and it reflects directly the bearing capacity:Qa = (C/F) × PLWhere: Qa = Allowable bearing capacityC = Shape factorF = Safety factor • The modulus of deformation E is used to calculate settlements and is given by: E = (1 + ν) 2V(∆P/∆V) Where:ν = Poisson’s ratio V = Cavity volume at the middle of the elastic zone∆P/∆V = Pressure variation dependent on volume variationExample of pressuremeter test resultsACCESSORIES • Slotted casing assembly for direct driving of the AX-sizeprobe in granular soils below the water table • Creep test kit for long term testing at constant pressureSPECIFICATIONSCONTROL UNITWorking pressure (max.) 10 000 kPa (1500 psi) Gauge precision 0.05% FS Gauge resolution 1 kPa Actuator capacity 10 tons Dimensions L = 40 cm W = 46 cm (including handles) H = 45 cm Metal case weight 30 kg Actuator weight 28 kg PROBES Diameter 74 mm (NX Long) 44 mm (AX)* Length 72 cm 59 cm Weight 6.4 kg 4.5 kg *For use with slotted casing E5001A-110330。
The TEXAM eis the new electronic version of the TEXAM pressuremeter in which the pressure and deformation are measured with electrical sensors and read with a tablet -operated readout.EASY TO OPERATE PRESSUREMETERREAL TIME READING AND PLOTTING OF TEST RESULTS RUGGED CONSTRUCTION∙ Electronic version of the TEXAM∙ Easy to operate and maintain ∙ Rugged construction∙ Controlled rate of deformation or pressure ∙ Conforms ASTM D4719-07 ∙ Safe : no compressed gas necessary ∙ Versatile: Easy cyclic or creep testing∙Automatic acquisition & real time visualisation for enhanced control of the test on an Android tablet*Key FeaturesDescriptionThe TEXAM epre -boring pressuremeter is a rugged and reliable instrument that can be used for various ground engineering applica-tions. This pressuremeter distinguishes itself by its ease of use and versatility. Loading is done manually with a screw jack, which allows the user to run tests in either strain or stress controlled steps. The manually -controlled hydraulic loading system ensures a good re-peatability of the test, while making unload -reload cycles very easy. The new electronic version of the TEXAM pressuremeter makes general operation of the equipment even easier and repeatable.This equipment includes the following parts.A control unit houses electrical pressure and volume sensors, con-nectors, a control valve and a manual actuator (screw jack) for pres-surizing the water in the cylinder via a piston.A readout unit consists of the DP Box unit operated with an Andoid tablet. This versatile readout is compatible with other pressure-meters manufactured by Roctest. A special application, installed on the tablet, allows configuring the tests and calibrations, to read and plot the test results in real -time, to log the data, and to review test results.A water -filled probe is fitted with an easy -to -replace single outer sheath. This sheath consists of rubber typically protected with metal-lic fins.And finally an easy -to -repair, high -pressure tubing connects the probe to the control unit.TEXAM e - Pressuremeter∙ Bearing capacity and settlement estimation of alltypes of foundations∙ Deformation of laterally loaded piles and sheet pilesApplicationsPlease specify:∙ Tubing length (25, 33 , or 50 m) ∙ Probe diameter∙ Accessories (metallic sheaths, rings) and optional itemsSpecificationsRoctest Ltd, 680 Birch Street St -Lambert, Quebec Canada J4P 2N3Phone +1 450 465 1113 Fax. +1 450 465 1938 ********************* Web Roctest reserves the right to make any changes in the specifications without prior noticeE5001E -180202Control unitWorking pressure 10 000 kPa (1500 psi) Dimensions40 x 46 x 125 cm (l x w x h) as-sembledWeight30 kg / 28 kg (Box / Actuator) D/P BOX Readout unitUser Interface Bluetooth communication with an Android tablet Resolution 1 kPa and 0.01 cm 3 Power Supply 2 x 12 V, 2.3 A, rechargeable batteriesDimensions 25 x 28 x 12 cm (l x w x h)Housing Splashproof, resistant ABS case Autonomy> 8 hours typicallyPower supply interfaceUniversal AC wall plug with US/Euro adapter + adapter cable for car (lighter) & for external batteryProbeDiameter 74 mm (N Long) / 44 mm (A) Length 72 cm / 84 cm Weight6.4 kg / 4.5 kg Max radial expansion35 %Test ProcedureThe probe is placed at the test depth in a pre -drilled borehole obtained by a method adapted to the soil conditions: wet rotary drilling, auger-ing, shelby tube pushing, etc. In granular soils below the water table, the probe can be driven directly within a slotted cas ing. The test is run either with a constant rate of deformation by using a uniform rate of rotation of the actuator, or with equal increments of p ressure as for the Menard pressuremeter test.Typical Pressuremeter Test ResultsTest ResultsAn in -situ stress -strain curve is obtained by plotting the injected vol-ume against pressure. The main parameters yielded from the test readings are the Pressuremeter Modulus, Creep Pressure, and the Limit Pressure. A tool (TexamCompanion) developed by Roctest can be used for that purpose.Ordering InformationOptional Accessories∙ A high -precision digital gage kit tobe connected on the front panel as a backup reading.∙ A mechanical volume counter to install on the handle shaft, also for backup reading.∙A slotted casing assembly compat-ible with A -size probe, for use in difficult soils (gravely soils).TEXAM e- PressuremeterDigital Pressure Gagae KitNote that the TEXAM eis compatible with the BOREMAC and PENCEL Probes - see sparate brochures for more details.Note: D/P BOX & Android Tablet sold separately。
SERIES 475 MARK III DIGITAL MANOMETERMADE IN U.S.A.475-000-F M 475-00-F M BATTERY INSTALLATIONRemove the two screws holding the bottom endcap and remove it. Connect the battery to the enclosed battery clip, observing correct polarity.When replacing the cover be sure the rubber sealing gasket is properly seated in the gasket channel of the endcap. Note the endcap will only fit one way.The holes are slightly offset to center. Replace the screws, DO NOT OVERTIGHTEN.LOW BATTERY INDICATORA weak battery can cause improper operation or inaccurate measurements. When the low batindicator is illuminated replace the battery. Do not leave exhausted battery in the unit due to the risk of leakage.475-AV AIR VELOCITY KITComplete kits include a Series 475 manometer(standard ranges as shown on back of card), (2) No. A-303 static pressure tips, (2) nine ft. lengths of 3/16î I.D. rubber tubing, a Model 166-6-CF , 6î Pitot tube, No. A-397 step drill, No. A-532 air velocity slide chart and instruction bulletin H-11. All items are packed in a tough molded plastic carrying case with die cut foam liner.475-0-F M475-1-F M 475-2-F M 475-3-F M 475-4-F M 475-5-F M 475-6-F M 475-7-F M475-8-F MCOPYRIGHT 2003 DWYER INSTRUMENTS, FR. 02-443041-00 Rev. 9C475-00-FM 0-4.00 IN W.C. (0-.995 kPa) 5 PSIG (35 kPa)475-0-FM 0-10.00 IN W.C. (0-2.49 kPa) 5 PSIG (35 kPa)475-1-FM 0-19.99 IN W.C. (0-4.97 kPa)10 PSIG (68.9 kPa)475-2-FM 0-40.0 IN W.C. (0-9.95 kPa)10 PSIG (68.9 kPa)475-3-FM 0-199.9 IN W.C. (0-49.7 kPa)30 PSIG (207 kPa)475-4-FM 0-10 PSID (0-.689 bar)30 PSIG (207 kPa)475-5-FM 0-19.99 PSID (0-1.378 bar)60 PSIG (4 bar)475-6-FM 0-30.00 PSID (0-2.07 bar)60 PSIG (4 bar)475-7-FM 0-100 PSID (0-6.89 bar)150 PSIG (10 bar)475-8-FM0-150 PSID (0-10.34 bar)150 PSIG (10 bar)MODEL PRESSUREMAX PRESSURE 475-000-FM 0-1.00 IN W.C. (0-.249 kPa)10 IN W.C. (2.5 kPa)OPERATING INSTRUCTIONSOn/Off OperationPress the I/O key to switch the unit on and off.Pressure unit selectionPress the E/M key to switch between english or metric units.Zeroing pressure unitsPotential inaccuracy due to temperature effects can be minimized by re-zeroing immediately before each use. To zero the display, vent both pressure ports to atmosphere. Adjust the knob on top until the displayreads exactly zero.OverpressureExceeding the range of the manometer will not damage it or affect calibration if the maximum pressure is not exceeded. Do not exceedthe maximum rated pressure established for your specific manometer model. Doing so will cause permanent damage to the sensor and may rupture the housing and/or cause injury. The maximum pressure is shown on the rear label of the manometerand on these instructions.PHONE: 219-879-8000 FAX: 219-872-9057 e-mail: info@ DWYER INSTRUMENTS, INC.102 HIGHWAY 212, MICHIGAN CITY, IN. 46360Service: Air and combustible, compatible gases.Wetted Materials: Consult Factory.Accuracy: +/-0.5% F .S., 60 to 78°F (15.6 to 25.6°C); +/-1.5% F .S. from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40°C).Pressure Hysteresis: +/-0.1% of full scale.Pressure Limits: See chart.Temperature Limits: 32 to 104°F (0 to 40°C).Storage Temperature Limits: -4 to 176°F (-20 to 80°C).Display: 0.5˝ liquid crystal. 3-1/2 digits.Resolution: See chart.Power Requirements: 9 volt alkaline battery (Up to 100 hours of operation). Battery not connected.Weight: 10.8 oz. (306 g).Connections: Two barbed connections for use with 1/8˝ (3.18 mm) or 3/16˝ (4.76mm) I.D. tubing. Two compression fittings for use with 1/8˝(3.18 mm) I.D. x 3/16˝ (4.76 mm) O.D. tubing for 475-7-FM and 475-8-FM.Agency Approvals: FM, CE.Size: 6-9/16˝ H x 2-13/16˝ W x 29/32˝ DSPECIFICATIONS:。
Principles of OperationMost Trerice Pressure Gauges are constructed with a bourdon tube sensing element. When the sensing element is subjected to pressure, it flexes and the resulting motion is transmitted as a measurement through a mechanical movement to the dial face pointer.Pressure GaugesDESIGN & OPERATIONSelecting a Pressure GaugeCaseCases are available in a wide variety of materials andconfigurations. The combination of material and configuration is generally determined by the demands of the application, as well as the preferences of the gauge specifier. The moredemanding the environment, the more rugged the case construction (i.e., polypropylene or stainless steel for industrial applications vs. aluminum or steel for construction or commercial applications).Gauge mounting or retrofitting needs may affect case selection (i.e., a gauge to be panel mounted will require either a front flange or u-clamp style case). For safety considerations, a “solid-front”case style may be required. Each application will have a unique set of requirements which will help guide the specifier in selecting the appropriate case style.Wetted Parts and Pressure MediumUnder normal operating conditions, only the tube and socket assembly (Wetted Parts) of a pressure gauge will come into contact with the fluid being measured (Pressure Medium). The selection of the assembly will be determined by the composition of the medium. Air, gas, steam, water and other non-corrosive media are usually satisfied by a bronze or brass bourdon tube and brass socket assembly. Stainless steel or Monel wetted parts are used when the medium contains corrosive elements or when high operating pressures or temperatures will be encountered. A diaphragm seal is recommended for highly corrosive media or that which may solidify or depositsolids within the tube and socket assembly of the gauge. (See the Diaphragm Seal section of this catalog.)CASEBLOW-OUT BACK DIAPHRAGMBOURDON TUBEMOVEMENTSOLID CASE FRONT DIALPOINTERRINGWINDOWSEALSOCKETConnection and MountingThe socket connection provides an entrance port for the process medium as well as a means to mount the gauge to a pipeline or vessel. Male connections can be provided with NPT, BSPT, or other thread styles, in sizes from 1/8" through 1/2". A high-pressure, 9/16" LHT connection is also available. The mounting location indicates where the connection protrudes from the case. Trerice Pressure Gauges are available with three standard mounting locations: lower male (LM), lower back male (LBM), and center back male (CBM). Other connection locations may be available on some models.Window and RingThe window provides a means for viewing the measurement, as well as protection of the dial face and pointer of the instrument, and is normally held in place by a ring, which is screwed or snapped to the case of the gauge. Plastic, clear glass and laminated glass are common window materials. Ring styles include threaded, bayonet, friction, crimped and hinged, depending upon the case type. PointerThere are essentially three types of pointers available on Trerice Pressure Gauges: a micro-adjustable pointer (providing high quality and accuracy); a friction-type pointer (providing adjustability and durability); and a plain, non-adjustable pointer (providing economic reliability). AccuracyThe accuracy of a pressure gauge is expressed as a percentage (plus or minus) of the maximum scale range. Please refer to Pressure Gauge Standard ASME B40.100.Liquid FillingLiquid filling (glycerin, silicone or other fills) can prolong the life of a pressuregauge by minimizing wear on the gauge internal resulting from vibration or oscillation. Liquid filling also acts as a permanent lubricant to the moving partsof the instrument.。
气压计操作说明书1. 气压计操作说明书说明书目录:1. 概述2. 操作前准备3. 气压计使用步骤4. 操作注意事项5. 故障处理6. 维护与保养1. 概述气压计是一种用于测量大气压力的仪器。
本操作说明书旨在为用户提供正确的操作指导,确保仪器的正常运行和准确测量。
2. 操作前准备在开始操作之前,请确保具备以下条件和步骤:2.1 确认环境确保使用气压计的环境稳定且适宜。
避免在有强烈振动、温度过高或过低以及有腐蚀性气体存在的环境中使用气压计。
2.2 检查设备完整性检查气压计的外观,确保无任何明显损坏或松动的部件。
若发现异常,请及时联系维修人员进行检修和修复,切勿私自操作。
2.3 供电连接若气压计是基于电力的,需要将其正确连接到电源以确保正常运行。
请参考气压计的电源连接说明进行正确连接。
3. 气压计使用步骤请按照以下步骤正确操作气压计:3.1 打开开关将气压计的开关置于“ON”(或相应的启动位置),以启动气压计的工作。
3.2 设置参数根据实际需要,调节气压计的相关参数,如单位、测量范围等。
请参考气压计的参数设置说明进行正确设置。
3.3 将探头放置于测量区域将气压计的测量探头放置于待测区域,确保探头与被测介质完全接触,并保持稳定。
3.4 进行测量观察气压计的显示屏,记录测量结果。
当数值稳定后,可视为测量完成。
4. 操作注意事项在使用气压计时,需要注意以下事项,以确保测量结果的准确性和仪器的安全稳定:4.1 避免外界干扰尽可能避免气压计受到外界振动、震荡和冲击等干扰,以免影响测量精度和稳定性。
4.2 注意操作安全在操作过程中,遵循相关的安全操作规程,避免触碰高温表面、高压部件或其他可能对人身安全造成伤害的区域。
4.3 防止介质浸润气压计通常不适用于测量液体和腐蚀性气体压力,以免损坏仪器。
请在使用前阅读仪器的应用说明书,了解其适用范围。
5. 故障处理在使用过程中,可能会遇到一些故障或异常情况。
若发现仪器不工作或有明显异常,请务必采取以下步骤:5.1 停止使用在发现故障后,应立即停止使用气压计,并将其断开电源或其他供电方式。
(/en.html)UNITED STATESDISTRIBUTORS (/EN/DISTRIBUTORS.HTML)STUDENTS (/EN/STUDENTS.HTML)CAREERS (/EN/CAREERS.HTML)ABOUT (/EN/ABOUT-US.HTML)NEWS (/EN/ABOUT-US/NEWS-ROOM.HTML)VIEW CART (0)Search WelchAllyn.co TYCOS CLASSIC HAND ANEROIDS®Overview (/en/products/categories/blood-pressure-measurement/sphygmomanometers/tycos-aneroids/tycos_classic_hand_aneroids.html)Parts & Accessories (/en/products/categories/blood-pressure-measurement/sphygmomanometers/tycos-aneroids/tycos_classic_hand_aneroids/parts-and-accessories.html)Documents (/en/products/categories/blood-pressure-measurement/sphygmomanometers/tycos-aneroids/tycos_classic_hand_aneroids/documents.html)Products (/en/products.html)Parts & Accessories (/en/parts.html)Service & Support (/en/service-support.html)Insights & Research (/en/insights-and-research.html)(/projects/j1code=%25%3A-F%40%5CJH%20%0A&sc=VEVTVFQ%3DQUICK TOOLSThis product is no longer available for sale. To view support options, parts and accessories, click through to the product page.FeaturesTechnical Library (/en/service-support/document-library.html)Warranty Registration (/en/service-support/standard-warranty-registration.html)Submit a Repair Service Request (/en/service-support/submit-a-repair.html)Service Center Landing Page (/en/service-support.html)Service & SupportProduct SpecificationsShipping Weights & DimensionsHeight: 3.1 INWidth: 5.9 INDepth: 3.4 INWeight: 0.7 LBConnects to EMR? NoProduct Warranty: TEN YEAR WARRANTYSpecifications are for a 'typical' configuration. Click on any part number link to see part number specific details.Top FAQsWhat makes a Tycos brand sphygmomanometer from Welch Allyn better than other brands?(/en/service-support/answer-center/student/-what-makes-a-tycos-brand-sphygmomanometer-from-welch-allyn-bett.html)Q:The term "certified" is printed on the Welch Allyn Tycos blood pressure gauge dials. What does thisindicate? (/en/service-support/answer-center/student/the-term--certified--is-printed-on-the-tycos-dials--what-does-th.html)How do I find a Welch Allyn Distributor? (/en/service-support/answer-center/orders---billing/cshm185-find-a-distributor.html)Q:Q:View All FAQs (/en/service-support/answer-center.html#query=Tycos%20Classic%20Hand%20Aneroids)Top DocumentsPocket and Handheld Aneriod Sphygmomanometers, User Manual, Multi-Language(/content/dam/welchallyn/documents/sap-documents/LIT/80012/80012661LITPDF.pdf)DS58 Hand Aneroid Product Insert, Brochure (/content/dam/welchallyn/documents/sap-documents/LIT/80015/80015223LITPDF.pdf)View All Documents (/en/service-support/document-library.html#query=Tycos%20Classic%20Hand%20Aneroids)Products All (/en/products.html)Physical Exam (/en/products/categori es/physical-exam.html)Patient Monitoring (/en/products/categori es/patient-monitoring.html)Blood Pressure Measurement (/en/products/categori es/blood-pressure-measurement.html)Thermometry (/en/products/categori es/thermometry.html)Cardiopulmonary (/en/products/categori es/cardiopulmonary.ht ml)Parts & Accessories Batteries (/en/parts.html#query =&part-type=Batteries)Lamps (/en/parts.html#query =&part-type=Lamps)Cables and Sensors (/en/parts.html#query =&part-type=Cables%20and%20Sensors)Power Supplies,Cords & Chargers (/en/parts.html#query =&part-type=Power%20Supplies/Cords/Chargers)Connectors & Tubing (/en/parts.html#query =&part-type=Connectors%20and%20Tubing)Service & Support Service Center (/en/service-support.html)Answer Center (/en/service-support/answer-center.html)Partners in Care (/en/service-support/partners-in-care.html)Find a Distributor (/en/service-support/distributor-lookup.html)Supplier (/en/wa-for-suppliers.html)Document Library(/en/service-support/document-library.html)Insights & Research (/en/insights-and-research.html)Clinical Evidence (/en/insights-and-research/case-studies.html)Facility Planning (/en/insights-and-research/facility-planning.html)EMR Connectivity (/en/insights-and-research/emr-connectivity.html)Webinars(/en/insights-and-research/webinars.html)Clinical Evidence(/en/insights-and-research/clinical-evidence.html)NewsletterSign-up (http://welchall yn.hqcampaig /ps/gene ral-opt-in)Facebook (https://www.f /welchallyn)Twitter (https:///WelchAlly n)LinkedIn (http://www.lin /co mpany/welch-allyn)YouTube (https://www.y /us er/welchallyn)Medical Lighting(/en/products/categori es/medical-lighting.html)Animal Health(/en/products/categori es/animal-health.html) Promotions(/en/products/promoti ons.html)Probe Covers /Thermometry(/en/parts.html#query=&part-type=Probes/Covers%20-%20Thermometry)See all parts &accessories(/en/parts.html)Technical Training(/en/service-support/partners-in-care/education-services/technical-training.html)Email Us(/en/other/contact.html)Call Us(/en/other/contact-us.html)Facility Planning(/en/insights-and-research/facility-planning0.html)EMR Connectivity(/en/insights-and-research/emr-connectivity0.html)Distributors Distributor Tools & Portals(/en/distributors.html) Become a Distributor (/en/distributors/beco me-a-distributor.html)Students(/en/students.html)Ripple Effect(/en/students/ripple-effect.html)Ripple Effect Top 10Participants(/en/students/ripple-effect-top-10-participants.html)Student Warranty(/en/students/student-warranty.html)Student ClinicalLearning(/en/students/student-clinical-learning.html)OphthalmoscopyPathologies(/en/students/ophthalmoscopy-pathologies.html)Otoscopy Pathologies(/en/students/otoscopy-pathologies.html)Careers(/en/careers.html)Career Paths(/en/careers/career-paths.html)About (/en/about-us.html)History (/en/about-us/history.html)Leadership(/en/about-us/leadership.html)Innovations(/en/about-us/innovations.html)High PerformanceHealthcare(/en/about-us/high-performance-healthcare.html)Corporate SocialResponsibility(/en/about-us/corporate-social-responsibility.html)Locations (/en/about-us/locations.html)News Room(/en/about-us/news-room.html)100 Year Anniversary(/en/about-us/100-Year-OtherCorporate Policies(/en/other/corporate-policies.html)Privacy Policy(/en/other/privacy-policy.html)Terms of Use(/en/other/terms-of-use.html)Contact(/en/other/contact-us.html)Anniversary.html)®© 2014 Welch Allyn All rights reserved。