微波消解-电感耦合等离子发射光谱法测定面粉中滑石粉的含量
- 格式:pdf
- 大小:228.33 KB
- 文档页数:3
微波消解与ICP-AES联用测定糖果以及蜜饯中滑石粉的含量沈君璐;顾锦明;杨晶晶【摘要】采用微波消解对样品快速消解,采用氢氟酸、硝酸与双氧水处理样品,使滑石粉中的镁转化成Mg2+。
同时用ICP-AES(电感耦合等离子发射光谱法)测定样品中的滑石粉含量,Mg含量在0.5~5 mg/L范围内与光谱强度线性相关,线性相关系数为0.9997。
测定结果的相对标准偏差为4.87%~6.38%( n=6),回收率为93.3%~103.1%。
%This method ifrst used microwave digestion technique to digest samples rapidly. Then samples were dipped in hydrofluoric acid, nitric acid and hydrogen peroxide which made magnesium in talcum powder converted to Mg2+. And use ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrometry) method to measure the talcum powder content in samples. The Mg content was linear correlation with spectral intensity in range of 0.5 mg/L to 5 mg/L, the linear correlation coefifcient was 0.999 7. The relative standard deviation of measurement results was 4.87% to 6.38% (n = 6), the recovery rate was 93.3% to 103.1%.【期刊名称】《上海计量测试》【年(卷),期】2015(000)002【总页数】4页(P30-33)【关键词】微波消解;电感耦合等离子发射光谱;糖果;蜜饯;滑石粉【作者】沈君璐;顾锦明;杨晶晶【作者单位】上海市浦东新区质量计量检测所;上海市浦东新区质量计量检测所;上海市浦东新区质量计量检测所【正文语种】中文蜜饯是人们日常喜欢的零食,国家规定其含滑石粉有一定的限量,但有些商贩为了产品美观,并降低成本,通常会加过量,长期食用滑石粉对人体有一定的危害。
微波消解-火焰原子吸收光谱法间接测定小麦粉中的滑石粉罗叶丽;董梅;武鑫;强鑫
【期刊名称】《粮食与油脂》
【年(卷),期】2024(37)4
【摘要】建立微波消解-火焰原子吸收光谱法测定小麦粉中滑石粉含量的方法。
通过对消解系统酸用量和释放剂氯化锶加入量的优化,最终确定选用硝酸-氢氟酸体积比5∶1作为消解用酸,以每100 mL试样溶液中加入2.0 mL 15 g/L氯化锶溶液来达到消除干扰的目的,经过方法学验证,结果表明:在0.2~1.0 mg/L范围内线性良好,相关系数r为0.999354;在加入镁元素的含量分别为1153.8、2884.6、7692.3μg/g时,平均回收率分别为101.0%、102.0%和102.3%,方法的相对标准偏差为0.44%,检出限为0.0040 g/kg,定量限为0.0134 g/kg,实际样品测定结果满意。
【总页数】4页(P150-152)
【作者】罗叶丽;董梅;武鑫;强鑫
【作者单位】渭南市检验检测研究院;富平县检验检测中心(陕西省羊乳产品质量监督检验中心)
【正文语种】中文
【中图分类】TS210.7
【相关文献】
1.微波消解-石墨炉原子吸收光谱法测定小麦粉标样中镉的含量
2.微波消解石墨炉原子吸收光谱法测定小麦粉中镉含量的不确定度分析
3.微波消解火焰原子吸收光谱法测定土壤中六价铬
4.微波碱消解-火焰原子吸收光谱法测定土壤中六价铬
5.微波消解-火焰原子吸收光谱法测定冷轧碱性脱脂剂中钙、镁的含量
因版权原因,仅展示原文概要,查看原文内容请购买。
滑石粉检测项目
滑石粉(Talc)通常用于化妆品、药妆和工业制品中。
以下是
滑石粉常见的检测项目:
1. 粒径分布:滑石粉的颗粒大小对其应用特性和性能具有重要影响。
常用的测试方法包括激光粒度仪等。
2. 水分含量:检测滑石粉中的水分含量,通常使用烘箱法或卡尔费休法。
3. 可溶性物质:滑石粉中的可溶性物质包括杂质、金属离子等。
常用的测试方法包括水溶液浸提、离子色谱法等。
4. 纯度:检测滑石粉中的杂质含量,常用的方法有灰分、硅酸盐含量的测定。
5. 重金属含量:检测滑石粉中的重金属含量,如铅、汞、镉等。
常用的测试方法包括原子吸收光谱法、电感耦合等离子体发射光谱法等。
6. pH值:检测滑石粉的pH值,通常使用酸碱滴定法。
7. 粉尘爆炸性:检测滑石粉的粉尘爆炸性,通常使用粉尘爆炸指数测试仪等。
8. 粘度指数:检测滑石粉的流动性和粘度,通常使用流变仪等测试仪器。
以上仅列举了一些常见的滑石粉检测项目,具体根据需要和使用场景,还可以有其他适用的检测项目。
微波消解-电感耦合等离子体质谱法测定滑石粉中多种痕量金属元素胡晓静;庞艳华;赵景红;盛向军;任玉伟;张华一;陈新;王玉萍【摘要】样品经微波消解后,应用电感耦合等离子体质谱法测定了滑石粉中Pb、Cd、Cr、As、Sb、Cu、Zn、Mn、Ni、Mo、Co、Sr共12种痕量金属元素.考察了微波消解体系、质谱干扰和基体效应等因素对测定的影响.结果表明:在最佳消解程序(在250 W消解2 min,在0W停留2 min,在450 W消解5 min,在550 W消解5 min)下15 mL硝酸能够完全消解0.5g滑石粉样品,质谱干扰可以通过选择同位素以及校正方程消除,基体效应的影响可以在线加入合适的内标元素克服.将方法应用于实际样品分析,待测元素的加标回收率在95%~109%之间,相对标准偏差(RSD,n=8)在2.1%~12.0%范围,测定结果与石墨炉原子吸收光谱法(GF-AAS)、电感耦合等离子体原子发射光谱法(ICP-AES)和氢化物-原子荧光光谱法(HG-AFS)基本吻合.%After microwave digestion, the content of 12 trace metal elements in talcum powder was determined by inductively coupled plasma mass spectrometry, including Pb, Cd, Cr, As, Sb, Cu, Zn, Mn, Ni, Mo, Co and Sr. The results showed that 0. 5 g of talcum powder sample could be fully digested with 15 mL of nitric acid under optimal digestion procedures (digestion at 250 W for 2 min, keeping at 0 W for 2 min, digestion at 450 W for 5 min and then digestion at 550 W for 5 min). The mass spectrometric interference could be eliminated by selecting isotopes and using correction equation. The influence of matrix effect could be overcome by on-line adding proper internal standard elements. The proposed method was applied to the analysis of actual samples. Therecoveries of testing elements were between 95 % and 109 %. The relative standard deviations (RSD, n = 8) were in range of 2. 1 % -12. 0 %. The determination results were consistent with those obtained by graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and hydride generation atomic fluorescence spectrometry (HG-AFS).【期刊名称】《冶金分析》【年(卷),期】2011(031)011【总页数】5页(P29-33)【关键词】微波消解;电感耦合等离子体质谱法;痕量元素;滑石粉【作者】胡晓静;庞艳华;赵景红;盛向军;任玉伟;张华一;陈新;王玉萍【作者单位】辽宁出入境检验检疫局,辽宁大连116001;辽宁出入境检验检疫局,辽宁大连116001;辽宁出入境检验检疫局,辽宁大连116001;辽宁出入境检验检疫局,辽宁大连116001;辽宁出入境检验检疫局,辽宁大连116001;辽宁出入境检验检疫局,辽宁大连116001;辽宁出入境检验检疫局,辽宁大连116001;辽宁出入境检验检疫局,辽宁大连116001【正文语种】中文【中图分类】O657.63;P619.25滑石作为一种关系国计民生的重要战略物资,历来倍受各国关注。
微波消解—电感耦合等离子质谱法测定粮食中44种元素方亚敏;张慧敏;朱圆圆;熊丽蓓【摘要】目的建立微波消解-电感耦合等离子体质谱法测定粮食中锂、铍、钡、钠、镁、铝、钾、钙、钒、铬、锰、铁、钴、镍、铜、锌、砷、硒、锶、钇、钼、银、镉、锡、锑、镧、铈、镨、钕、钷、钐、铕、钆、铽、镝、钬、铒、铥、镱、镥、铊、铅、钍、铀方法.方法样品采用经微波消解后,用电感耦合等离子体发射质谱法同时测定44种元素的含量.结果灵敏度高,各元素检出限在0.00008~0.30 mg/kg之间;线性良好,线性相关系数均≥0.995;各元素的加标回收率在79.1%~130%.结论此方法简便、快速、准确、灵敏度高,能满足食品卫生标准需要.【期刊名称】《首都公共卫生》【年(卷),期】2017(011)006【总页数】5页(P262-266)【关键词】微波消解;电感耦合等离子体质谱法;粮食;元素检测【作者】方亚敏;张慧敏;朱圆圆;熊丽蓓【作者单位】200336,上海市疾病预防控制中心化学品毒性检定所;200336,上海市疾病预防控制中心化学品毒性检定所;200336,上海市疾病预防控制中心化学品毒性检定所;200336,上海市疾病预防控制中心化学品毒性检定所【正文语种】中文【中图分类】R155.5+1外界环境的金属污染会通过各种途径在人体内代谢与蓄积,从而直接或间接影响人们的健康,如近期报道的“水俣病”、“含铅小龙虾”、“镉大米”等[1]。
因此食品中金属元素的测定是非常必要的,尤其建立粮食重金属检测方法是保障我国食品安全的重要手段。
目前食品中元素的分析主要采用紫外—可见光分光光度法、原子吸收分光光度法、原子荧光光度法、原子发射光谱法等[1]。
其中,紫外—可见光分光光度法不能实现多元素的同时检测,准确度相对较低,重现性差;石墨炉原子吸收光度法检测速度慢;火焰原子吸收分光光度法检出限高;原子荧光光度法仅用于测定砷、汞、硒等元素的测定;原子发射光谱法的灵敏度、检出限以及重现性都不如电感耦合等离子体质谱法(ICP-MS)。
微波消解-电感耦合等离子体质谱法测定粮食中12种重金属元素张莹;曾丹;柴微波【期刊名称】《理化检验-化学分册》【年(卷),期】2014(000)007【摘要】粮食样品用硝酸-过氧化氢微波消解处理,采用电感耦合等离子体质谱法测定样品溶液中12种重金属元素(砷、铅、镉、硒、铬、铊、锰、镍、铜、铀、钴、钒)的含量。
采用内标法消除基体的影响。
方法的检出限(3S/N)在0.092~17.5 pg·g-1之间。
方法的加标回收率在88.1%~118%之间,相对标准偏差(n=5)小于6.0%。
方法用于鸡肉标准物质(GBW 10018)中重金属含量的测定,测定值与认定值相符。
【总页数】4页(P875-878)【作者】张莹;曾丹;柴微波【作者单位】天津大学分析测试中心,天津 300072;天津大学药物科学与技术学院,天津 300072;天津大学药物科学与技术学院,天津 300072【正文语种】中文【中图分类】O657.63【相关文献】1.微波消解-电感耦合等离子体质谱法测定藻类中4种重金属元素 [J], 张丹;张琳;王俊红;于伯华;杨瑞章;孙宇2.微波消解-电感耦合等离子体质谱法同时测定土壤中4种重金属元素 [J], 陈保;毛静春;刘新月;姜东华;罗正刚3.微波消解电感耦合等离子体质谱法同时测定生姜药材中\r6种重金属元素含量[J], 谭丽盈;胡国辉4.微波消解-电感耦合等离子体质谱法测定水生蔬菜中八种重金属元素 [J], 张惠贤; 姚晶晶; 王明锐; 崔文文5.微波消解-电感耦合等离子体质谱法测定注射用盐酸吉西他滨中6种重金属元素[J], 余师师;王鹏;钟振华;夏红英;王烜;程奇珍因版权原因,仅展示原文概要,查看原文内容请购买。
电感耦合等离子体原子发射光谱(ICP—AES)测定米粉、饼干、粉条、油条中的铝铝是一种低毒的金属元素,不会导致人体急性中毒,但是食品中铝元素含量超过一定量就会对人体造成危害。
關键词:电感耦合;离子体原子;铝人体经常摄入铝元素,对健康的威胁还是挺大的。
根据世界卫生组织的研究表明,人体的每千克体重每天允许摄入的铝元素的含量不可以超过1mg。
其主要来源是油炸早餐,如油条,炸糕等,另外一些膨酥食品也会含有少量铝。
在这些食品中,铝是作为添加剂添加到食品中的。
因此,开展食品中铝的快速检测,具有重要的意义。
本文用电感耦合等离子体发射光谱仪(ICP -AES)对常见食品中铝含量的测定方法进行了探索。
1 仪器与试剂(1)电感耦合等离子体原子发射光谱(ICP-AES):美国铂金埃尔默公司。
入射功率:1.3kw 冷却气体流量:8L/min吹扫气流量:0.2L/min 剪切气流量:0.8L/min样品溶液流量:2ml/min 观测方式:水平观测铝的分析线:(2)试剂。
盐酸:分析纯硝酸:分析纯高氯酸:分析纯铝标准储备溶液:ρ(Al)=1mg/mL(3)实验用水均为二次蒸馏水。
2 待测样品的制备(1)样品的准备:将米粉,粉条,饼干等待测样品于105℃烘干,然后以不含铝的研钵研成粉末,备用。
(2)样品的消解:准确称取1 g(精确至0.0002g)样品于100毫升烧杯中,加入20ml硝酸(ρ1.42g/cm3)和5ml高氯酸(ρ1.67g/cm3),加盖表面皿,置于通风橱中,浸泡过夜。
然后将盛有样品的烧杯分别放到电炉上低温加热,并用玻璃棒搅拌,直到样品消解完全,并蒸至高氯酸白烟冒尽,取下,冷却,用盐酸(1+99)温热溶解盐类,并定容到20毫升比色管中,摇匀,于电感耦合等离子体原子发射光谱仪上按选定的仪器条件测定样品中铝的含量。
3 标准曲线将铝的标准储备溶液ρ(Al)=1mg/mL逐级稀释,最后配制成铝的浓度分别为:0,0.5,1.0,2.0,4.0,8.0?g/mL标准系列溶液,溶液介质为盐酸(1+99)。