液位控制器JY-2A使用说明书
- 格式:pdf
- 大小:1.57 MB
- 文档页数:2
Refrigerating Specialties Division13093172 and Mode L is displayed. Using the arrow keys, set the low level to represent 2% of Full Scale (Full Scale = 100%) lower than the actual level setting required and press the enter key.• Example: If 80% is required for Channel 2 setpoint, set the channel 2 Low setting for 78%.• Push the channel button again to display Channel 2 and Mode H. Now set the High Level setting required for this channel and press Enter.• Note: 2% is the smallest value that can be en-tered. Larger differentials can be used to allow high liquid levels in the vessel to return to a safe operatingWiring:The separable terminal blocks on the PLLC will accom-modate up to 14 gage wire. The Line Voltage Input can be either 120/240V 60Hz or 110/220V 50Hz. The PLLC provides the power source for the current loop of the transducer probe. The programmable relays are indi-vidually 5 amp fused. Relays are equipped with normally open and closed terminals and can be wired as either. The maximum recommended distance between PLLC and probe is 5000 ft.Refrigerating Specialties Division2equipment failure."High" level setting.•channel.selected.First Modechange.Second ModeFig. 22445 S.25th Ave Broadview Ill 60155T708-681-6300 F708-681-6306。
正面侧面背面上面功能和用途本产品采用集成电路,并结合高层楼宇上、下水池(水塔)的水位分级提升进行设计,具有下下水池联合控制、水池排水及缺水保护等功能,可自动实现水箱补水、排水,并有效防止水池水位水高溢出或水泵空转损坏,是一种工业、家庭均适用的产品。
非常适合城镇、农村、学校、式矿企事业单位及家庭用水的水井——水井供水工程,广泛应用于印染、化工、食品、饮料、酿酒、制糖等行业。
性能特征(一)单控上水池控头安装说明安装图如图一所示:D(绿线)、E(黄线)点并接到C。
(二)单控下水池(即排水池)探头安装说明安装图如图二所示:E—为下水池上限液位控制点,水们上升达到E点水位,水与探头接触,水位控制器自动开泵,水池排水;若不排水,则E点不接;D—为下水池下限液位控制点,水位下降到D点水位,水与控头脱离接触,水位控制器自动关泵,水池停止排水;C—为水池地线,放地水池的最低点与水底部接触;A、B点不接。
(三)缺水保护探头安装说明安装图如图三所示:C、D点为水池下限水位控制点,水位下降到下限水位,C、D探头之一与水面脱离接触,水位控制器继电器立即动作,切断输出,水泵停止工作;E点与C点短接;A、B点不接。
(四)上下水池联合控制探头安装说明安装图如图三所示:A—为上水池(水塔)上限液位控制点,水位上升达到A点水位,水与控头接触,水们控制器自动关泵;B—为上水池(水塔)下限液们控制点,水位下降到B点水位以下,水与探头脱离接触,水位控制自动开泵,水池充水;C—为上、下不池(水塔)公用在线,放在上、下水池的最低点与水池底部接触;D—为下水池下限液位控制点,水位下降到D点水位,水与探头脱离接触,水位控制器自动关泵,水池停止排水;E—为下水池上限液位控制点,水位上升到E点水位,水与探头接触,水位控制器自动开泵,水池排头;若不排水,则E点不接。
安装尺寸安装使用其他说明1、为确保液位控制器正常工作,安装好后请再次检查输入输出的接线、探头连接线是否接触可靠。
液位自动控制器安全操作及保养规程液位自动控制器是一种常见的安全设备,它通常用于检测液体的液位并控制液体的流动。
使用液位自动控制器可以帮助我们提高工作效率,但是如果不正确地操作和保养,将会给人们的生命财产造成巨大的威胁。
本文将介绍液位自动控制器的安全操作及保养规程,以确保它的正常运行并保证其安全性。
1. 安全操作规程1.1 阅读说明书在使用液位自动控制器前,首先需要认真阅读使用说明书,了解其工作原理以及操作要点,以确保能够正确地使用该设备。
1.2 检查设备使用液位自动控制器之前要检查设备是否完好,下面是一些需要检查的项目:•涉及的仪器、设备、管道、阀门是否处于规定的运行状态•检查安装位置是否合适•检查控制器的供电电源•检查继电器、电源保护等部分是否完好1.3 安装设备安装液位自动控制器时,应根据使用说明书上的指南谨慎执行。
正确的安装可确保设备能够正常工作,并避免由于错误的安装导致的故障和事故。
1.4 操作设备在操作液位自动控制器之前,必须确保已经熟悉该设备的所有控制面板和按钮,且完全理解各个控制面板和按钮的作用。
在操作时应注意以下事项:•严格按照使用说明书上的指南进行操作•在操作过程中保持安静,不要对设备造成影响•操作过程中,应逐步感受由各个控制面板和按钮带来的变化1.5 关机和断电在使用完液位自动控制器后,必须关闭和断电。
操作方法如下:•将操作杆或其他控制控件调至最低点,切断电源•清洗和维护设备,以确保部件和部件之间的清洁与维护•将设备置于安全位置2. 保养规程定期维护液位自动控制器可以延长设备的寿命以及避免故障。
下面是一些保养的常用规程:2.1 定期维护了解设备的工作原理是进行维护的首要步骤,确保设备是在其完整和适合的状态下运行的。
通常,维护周期及内容如下:•检查管道和阀门是否磨损,是否需要更换•检查控制器的继电器状态,确认其正常运作•检查电机是否有漏电现象,是否受过热等2.2 清洁设备清洁液位自动控制器是维护的重要部分。
鸭嘴式浮球液位开产品手册一、产品概述鸭嘴式浮球液位开关是一种常用的液位检测和控制设备,主要用于检测和控制系统中的液位。
该产品采用不锈钢材料制作,具有结构简单、性能稳定、使用方便等特点,广泛应用于化工、石油、食品、制药等行业的液位检测与控制。
二、产品特点1.高可靠性:采用优质不锈钢材料制作,具有良好的耐腐蚀性能和长期稳定性。
2.安装简便:结构简单,安装方便,可根据实际需要调整安装位置。
3.维护方便:设计合理,维护方便,无需特殊工具即可进行拆卸和清洗。
4.多种规格可选:可根据实际需求选择不同规格的浮球液位开关,满足不同液位检测和控制要求。
5.适应性强:可适用于各种液体介质,如酸、碱、盐等腐蚀性液体和食品级液体。
三、工作原理鸭嘴式浮球液位开关的工作原理基于浮力原理和机械传动原理。
当液位发生变化时,浮球会随着液面的升降而上下浮动,通过连杆机构将浮球的位移传递到微动开关,从而控制电路的通断或输出信号。
根据不同的应用需求,可选择常开或常闭的输出方式。
四、安装使用说明1.在安装前应先确定液位检测的范围,选择合适规格的浮球液位开关。
2.根据安装位置的要求,确定浮球液位开关的固定方式,可采用法兰连接或螺纹连接等方式进行安装。
3.在使用过程中应定期检查浮球液位开关是否正常工作,如有异常应及时处理。
4.在对浮球液位开关进行维护和清洗时,应先切断电源,确保安全。
5.在安装和使用过程中应避免强烈的振动和冲击,以免影响浮球液位开关的性能和使用寿命。
五、常见问题及解决方案1.浮球无法正常浮动:可能是由于介质粘稠或管道内存在杂物等引起的。
解决方案是清洗浮球和管道,确保其表面光滑无杂物。
2.连杆机构松动或卡滞:可能是由于长时间使用或振动引起的。
解决方案是检查并调整连杆机构的螺丝或轴承等部件,确保其连接牢固且运动灵活。
3.输出信号不稳定:可能是由于液位波动过大或安装位置不当引起的。
解决方案是调整安装位置或增加滤波电路,以减小液位波动对输出的影响。
目录一、产品介绍1.概述 --------------------------------------------------------------3 2.主要技术指标 --------------------------------------------------3 二、计量仪表(二次仪表)操作说明1.键盘定义 -------------------------------------------------------4 2.计量操作 -------------------------------------------------------5 3.编程功能 -------------------------------------------------------8 三、装桶计量装置(φ40φ50)安装方法1.系统构成 --------------------------------------------------------9 2.泵的选择与安装 ----------------------------------------------10 3.流量变送器的安装 -------------------------------------------10 4.过滤器、平衡逆止阀、平衡管、表前直管段、铂电阻、胶管、油枪及油枪单向阀的安装 -------------------------10 5.装置安装注意事项 -------------------------------------------11 四、装桶计量装置(φ40φ50)的调试方法1.系统检查 -------------------------------------------------------11 2.余量计算 -------------------------------------------------------11 3.脉冲当量的测算 ----------------------------------------------12 4.密度的测算 ----------------------------------------------------12五、二次仪表的信号线及控制线的连接方法1.信号线的连接 ------------------------------------------------13 2.二次仪表控制线与交流接触器的连接 ------------------13六、装车计量装置(φ80φ100)的现场安装方法1.系统构成 -----------------------------------------------------14 2.泵的选择与安装 --------------------------------------------14 3.平衡逆止阀、平衡管的安装 -----------------------------15 4.铂电阻的安装 -----------------------------------------------16 5.流量变送器的安装 -----------------------------------------17 6.出口管道单向阀的安装 -----------------------------------17 7.装置安装注意事项 -----------------------------------------17 8.φ80卸车计量装置 -----------------------------------------17 七、安全注意事项-------------------------------------------------19 附录1 简易调整方法---------------------------------------------20 附录2 定时启动及无线遥控说明------------------------------21产品介绍1、概述YJK-II 液体流量定量控制仪是我公司自行研制生产的精度高、功能全、稳定可靠、技术领先的液体动态质量流量计量自控装置。
液位变送器使用说明液位变送器压力敏感核心采用了高性能的硅压阻式压力充油芯体,内部的专用集成电路将传感器毫伏信号转换成标准远距离的传输电流信号,可以直接与计算机接口卡、控制仪表、智能仪表或PLC等方便相连。
该系列产品广泛应用于工业过程控制、石油、化工、冶金等行业。
本产品符合GB 3836.1-2000 《爆炸性气体环境用电气设备第1部分:通用要求》、GB 3836.4-2000 《爆炸性气体环境用电气设备第4部分:本质安全型"i"》标准相应规定。
仪器防爆标志为:ExiaⅡCT4。
主要技术参数1、工作温度:0℃~70℃;2、绝缘电阻在参比工作条件下,变送器各端子对地之间的绝缘电阻不得低于20MΩ/250V。
3、防爆性能仪器防爆性能符合ExiaⅡCT4的要求。
4、 4-20mA无极性连接。
5、多级电气保护。
外形及安装外形结构见图,液位变送器(线缆投入式)由壳体、放大器、接线端子、防护帽、中空导线等组成;根据用户的需要可以选用智能数码表头或液晶表头显示。
安装方法⑴选择易于操作、维护的地方进行安装;⑵应尽量远离搅拌源、热源的地方安装;⑶投入式液位变送器安装时,金属探头要轻轻沉入容器底;电气连接打开仪表后盖(接线端子面),见接线端子,具体电气连接请参阅工业型压力变送器接线图。
直接引线式投入式液位计接线:红色线:电源正蓝色线:电流信号输出安全使用注意事项⑴搬运与安装变送器时应小心谨慎,避免碰撞而影响电路的性能。
⑵液位计进压口内有隔离膜片,切勿人为用异物触碰,定期清淤,以免阻塞。
⑶电气连接请严格遵照接线方法,接线错误会造成放大电路的损坏。
⑷投入式液位变送器安装,请勿利用导线吊装产品之外的重物。
⑸导线为特制防水导线,安装、使用过程中应杜绝磨损、刺破、划伤导线,若现场存在以上问题,导线应采取保护措施。
否则厂家维修时要收取相应的费用。
⑹安装使用中如遇到问题请及时与我公司联系,在产品发生异常时,请不要擅自打开进行修理。
水泵浮球液位控制器水位开关(完整版)实用资料(可以直接使用,可编辑完整版实用资料,欢迎下载)水泵浮球液位控制器水位开关浮球液位控制器重锤的装置法1、将浮球开关的电线从重锤的中心下凹圆孑L处穿入后,轻轻推动重锤,使嵌在圆孔上方的塑胶环因电线头之推力而脱落。
(如果有必要的话,也可用螺丝起子把此一塑胶环拆下,再将这个脱落的塑胶环套在电缆上你所想因定重锤以设定液位之位置。
(如右图1)2、轻轻地推动重锤拉出电缆,直到重锤中心扣住塑胶环。
**重锤只要轻扣在塑胶环中即不会滑落,此塑胶环如有损坏或遗失,可用同轻裸铜线扣入电缆代替。
3、在使用中,最好再用一根铜线或其他东西,把固定在线缆上(上下两端卡住)或容器内壁上,以防止重锤滑动而影响水位的控制。
请将电缆直接拉到控制箱,尽量避免使用中间接头,若不得已而有接头时,绝不可将电缆线接头浸入水中性能特点RM-UK221型浮球控制器是一个能够调节桶、槽或井中液位的开关。
它可自动调节、易于操作、便于安装、安全可靠、免予维修、无毒环保。
它对污水有抵抗作用。
广泛应用于家庭,厂矿等的水池、油、弱酸或弱碱的池、桶、糟、灌等容器之中。
如串联两个控制器,即一个放在水池,加一个放至水井来控制水泵,就能防止因水源不足开空泵而损坏水泵技术参数额定电流、电压:10(8A)250V~10(4A380V, 使用温度:0-80度使用范围:大于等于0.2M 工作寿命:1*50000 引线长度:4M(特殊的长度,特定的使用环境均可定制,可联系客服!)外形尺寸:80×160×45mm安装方式:用垂锤固定接线方法1、供水系统使用“黑色”和“蓝色”的电线:浮球在下水位时,接点是接通的状态浮球在上水位时,接点是不通的状态2、排水系统使用“黑色”和“褐色”的电线:浮球在上水位时,接点是接通的状态浮球在下水位时,接点是不通的状态安装实物图新版水位液位传感器控制器开关水箱塔池全自动抽水上水电子制作套件说明书该产品是根据家庭厂矿抽水实际需要而精心研发。
液位开关安装步骤说明书一、概述液位开关是一种用于检测液体高低水平的仪器设备,广泛应用于各种液体容器的液位监控和控制。
为了确保液位开关能够正确安装和操作,本文将详细介绍液位开关的安装步骤,并提供相关的注意事项和技术要求。
二、安装前的准备工作1. 确认液位开关的规格和型号,并核对相应技术资料,以便了解安装要求和技术参数。
2. 检查液位开关的外观和配件,确保没有损坏或缺陷。
3. 准备安装所需的工具和材料,包括螺丝刀、扳手、密封材料等。
三、液位开关安装步骤1. 确定安装位置:根据实际需要和安装要求,在液体容器上选择合适的位置进行安装。
同时,确保安装位置平坦、牢固,并有足够的空间容纳液位开关。
2. 清洁安装位置:使用清洁剂或干净的布将安装位置进行彻底清洁,确保表面没有灰尘、油脂等杂物,以便保证安装质量。
3. 安装支架:根据液位开关的型号和安装要求,将支架(如果有)安装在已经清洁的位置上。
支架应牢固并能够固定液位开关。
4. 安装液位开关:将液位开关放置在安装位置上,并用螺丝固定在支架上或直接固定在容器上。
固定时应注意力度适中,避免损坏液位开关或容器。
5. 连接电缆:根据液位开关的接线要求,将电缆与液位开关正确连接。
确保连接牢固,避免电缆松动或接触不良导致故障。
6. 密封处理:为防止液体泄漏或渗入液位开关,应在连接接口处进行密封处理。
可使用适当的密封材料或胶水进行密封,确保接口处完全密封。
7. 调试测试:完成安装后,进行液位开关的调试测试。
确保液位开关能够正常工作并准确地反映液位的高低变化。
四、注意事项1. 在安装过程中,注意保护液位开关的外壳和连接接口,避免碰撞或损坏。
2. 根据液体特性选择合适的液位开关型号,并确保其能够适应液体的温度、压力等工况参数。
3. 使用适当的工具和力度进行液位开关的安装和固定,避免过度拧紧或松动导致损坏。
4. 在进行电缆连接时,确保电源处于断开状态,避免触电或电器设备受损。
5. 如需进行定期维护或更换液位开关,应按照相应的维护手册或操作说明进行操作,确保正确和安全。
(多功能)液位控制器使用手册一、 简介目前,液位控制器大都使用3个不锈钢探头方式,工作原理是测量水的电阻,其弊端是:A、控制器水位传感工作在小电流(微安级)模拟状态,易受电磁干扰造成误动作。
B、输出方式单一,不能与电机综合保护器配合工作,易烧坏给水水泵。
C、控制器本身无水位保护,极易造成水箱溢出跑水。
D、在有上下水箱配合的环境无法工作,构成控制电路困难。
E、由于各地区、各种水质的导电性能不同,而且有些水质由于各种离子的存在,环境易构成原电池,更使电阻式水位控制器工作不稳定。
针对以上问题,一种高性能低价位液位控制器面市,具有如下特点:1、结构简单,性能优良,抗干扰性强,坚固耐用,平均无故障时间长达10年。
自动给水,不用人工管理,节省开支。
2、本控制器为多功能给水控制器,可应用于普通地面水箱、下卧式水箱、上位水箱、压力罐、深井泵等各种给水方式,上下位水箱配合式和压力罐方式可实现24小时给水。
3、操作简单;本控制器能在自动模式下长期稳定运行,在控制箱中可加自动手动运行转换开关,接线简单,工作方便灵活。
4、控制器本身有水位超高保护功能,当由于传感器失灵或其它原因造成水位超过高位水位时能够自动停机并自锁,防止水箱跑水。
5、本控制器工作在低压(DC12V)较大(5~10mA)电流,输入为开关量,不受水质影响,抗干扰能力极强,工作稳定。
6、输出端模拟启动停止按钮方式(2个继电器配合),可以与电机综合保护器配合工作,有效保护水泵电机。
二、 控制器性能1、该控制器为配电箱内安装器件,整机尺寸:纵72mm×横83mm×高113mm,自带导轨卡槽,安装方便。
2、各端子说明。
P1为输出1中点(单刀双掷的中点),P2为输出1常开点,P3为输出1常闭点。
P4为输出2中点(单刀双掷的中点),P5为输出2常开点,P6为输出2常闭点。
P7、P8为220V电源输入。
P9、P15为+12V直流输出,负载能力400mA电流,供外接传感器使用。
双色金属液位计调试说明
一、仪表控制面板说明
1.接线端子
为了方便记忆与说明,接线端子按如下方式命名:
端子分别为上下一组:
分别为:第一组,第二组,第三组;第四组,第五组,第六组,第七组,第八组
左端子盘为输入电压,下面1,3端子接 220 V AC ,2为接地,上面为仪表接线端子
右端子盘为输出电压,上面为接线盘输出电压 24 V DC,其中4,5一组,7,8一组,6为接地;下面为接仪表,4,5接红灯,7,8为绿灯。
2.光线调节
左面的调节旋钮为双色金属液位计红色亮度调节旋钮
右面的调节旋钮为双色金属液位计绿色亮度调节旋钮
3.电源开关
控制仪表电源供电的总开关
二、双色金属液位计调节
双色金属液位计光源下部分别有两个螺栓,首先拧松螺栓;然后调节光源两部螺杆,使得光源左右移动,站在液位计正前方,观察是否能够清晰的显示液位,其中水是绿色,气是红色。
重复多次,知道能够正确清晰显示液位为止。
三、工业摄像机调整
1、按照一定的接线方式接好线路
2、上下移动镜头,使得双色金属液位计的液位上下限正好铺满显示屏幕的上下限,此时拧紧螺栓,固定。
3、为以后维护方便,关闭摄像头图像控制器电源,以免工艺人员不小心按到面板按钮,制造不必要的麻烦!。