富来克FLECK5600说明书(流量控制)富来克FLECK5600 & 5600型ECONOMINDER® 设备参数:l项目号l*型号l水压试验l周期制水量最大/每次再生l树脂罐大小直径:高度l 盐水罐大小及每次再生盐耗设置:l控制阀规格计时器类型A)标准C)7天E)流量型,标准B)“L” D)12天F)流量型,扩展再生时间排污限流加仑/分钟盐箱注水速率加仑/分钟射流器大小流量设置加仑标准控制阀罐直径射流器慢冲洗速率@40 PSI 盐水吸取速率@40 PSI B.L.F.C.1 D.L.F.C.26˝7˝ # 0 红色# 0 红色0.31加仑/分钟0.31加仑/分钟0.28加仑/分钟0.28加仑/分钟0.5 加仑/分钟0.5 加仑/分钟8˝9˝10˝ # 1 白色# 1 白色# 1 白色0.45加仑/分钟0.45加仑/分钟0.45加仑/分钟0.38加仑/分钟0.38加仑/分钟0.38加仑/分钟0.5 加仑/分钟0.5 加仑/分钟0.5 加仑/分钟1.5 加仑/分钟2.0 加仑/分钟2.4 加仑/分钟12˝13˝ # 2 蓝色# 2 蓝色0.84加仑/分钟0.84加仑/分钟0.56加仑/分钟0.56加仑/分钟1.0 加仑/分钟1.0 加仑/分钟3.5 加仑/分钟4.0 加仑/分钟14˝16˝ # 3 黄色# 3 黄色1.0 加仑/分钟1.0 加仑/分钟0.3 加仑/分钟0.3 加仑/分钟1.0 加仑/分钟1.0 加仑/分钟5.0 加仑/分钟7.0 加仑/分钟因供水条件、罐大小和水压的不同,上述设置仅作为参考。
1B.L.F.C.(盐水注水限流):盐箱注水速率。
2D.L.F.C.(排污限流):反洗和快冲洗流速。
富来克5600型安装和启动程序软水器的安装,应根据制造商建议的入水口、出水口和排污口接管,且应符合相关管路规范。
1.将软水器控制阀手动转至工作位置,使水流入树脂罐。
当水流停止时,打开进出水口,直到管路内空气排尽,然后关闭进出水口。
安装1、安装的一般要求①、进水压力应在0.2-0.5MPa,当水源压力无法满足要求时,可安装增压水泵提高进水压力。
如果压力过高,应安装减压阀来控制进水压力。
②、进水温度应在5-45℃之间,电源采用交流200V/50Hz。
③、软水器应安装在牢固的平台上,附近有畅通的下水,并留有足够的操作和维修空间。
④、工作环境温度应在5-50℃之间,相对湿度≤95%(5℃时)。
2、控制阀的安装与树脂填装(顶装形式)第一步:首先将下布水器牢固安装在中心管底端,然后插入到树脂罐中央,在中心管上端低于罐口0.5mm处截断并导角,然后用胶带封住中心管口,以防树脂漏入。
第二步:将石英砂沿中心管周围空隙投入树脂罐,并使之在罐底铺平,石英砂高于下布水器上20mm,石英砂应按粒径级别分层铺装,主要起到布水作用(对于直径小于500mm树脂罐一般不装石英砂)。
第三步:将树脂均匀地装入树脂罐中,装至规定的层高后,再向注入10%的食盐溶液,至浸没树脂为止,使树脂充分膨胀。
树脂装填完,应取下中心管的封口胶带,上述操作时应注意使中心管始终保持在树脂罐口的中央位置。
第四步:将上布水器安装到控制阀上,然后将中心管从上布水器内插入到控制阀内,小心地沿顺时针方向转动控制阀,直至旋紧在树脂罐接口上(或用法兰连接固定)。
注意上布水器与控制阀、中心管,下布水器与中心管必须严密,防止树脂跑出。
中心管与控制阀必须严密不漏水,否则会出现窜硬水现象。
3、管道连接要求①、与软水器连接的管道应采用给水塑料管,排水管不得采用软塑料管,防止管道变形,影响排水效果。
②、按照控制阀进出水箭头标记连接进出水管,采用流量型再生控制器,流量计必须安装在出水口。
③、进出水管应装有压力表及手动阀门,同时还应装有旁通阀,在出水管阀前还应安装有取样阀。
进水管阀后一般安装有 Y 型过滤器,防止管道内污物堵塞阀体造成设备无法正常运行。
④、排水管的连接长度不应超过6m,尽量减少弯度,并严禁安装阀门。
目录一、产品概述 2二、工作流程图 3三、设备的安装和运行 5四、设备安装示意图 6五、FLECK5600控制器的调试步骤7六、故障排除9产品概述首先感谢您使用本公司的全自动软化水设备!为着方便您的使用,我们编写了该产品的客户手册,您的认真阅读和理解一定能为产品的良好使用打下基础。
5600系列自动软水器分为时间周期型和流量周期型两种控制方式,用户可以根据当地水质及用户对于水质的要求来进行选择。
本产品广泛应用于蒸汽和热水锅炉、热交换设备、食品加工、造纸印刷、洗衣印染、家庭、宾馆饭店、医疗制药、纯水制备预处理等行业。
我公司将给用户提供完善的技术及售后服务。
自动软水器技术参数:入口水压:0.2Mpa-0.6Mpa工作温度:2-50℃电源型式:220V/50Hz AC电源功率:3W出口硬度:≤0.03mmol/L再生方式:动态顺流再生或逆流再生树脂型号:001×7强酸性阳离子交换树脂盐耗:<160-240g/mol(根据水质情况)FLECK5600控制器工作流程图说明:FLECK5600和56SE控制器的水流过程略为不同,但原理一致。
1、工作状态2、预清洗(5min)3、反洗(10min)4、吸盐(50min)硬水经控制器进水口向下流过中心管、下布水器,向上流经树脂层,流出排水口,进行反洗。
硬水经控制器进水口流过树脂层,软化后经下布水器、中心管向上流出出水口,此时设备处于工作状态。
硬水经控制器进水口流过树脂层,软化后经下布水器、中心管向上流出排水口,进行预清洗。
硬水经控制器进水口,通过射流器,吸入盐液再生剂,向下流过树脂层进行再生还原,最后通过下布水器、中心管和排水口流出。
5、慢洗6、快洗7、稳层清洗 8、盐箱充水吸盐完成后,空气止回阀会将吸盐口封住,防止空气的进入,硬水继续经控制器进水口,通过射流器,向下流过树脂层,最后通过下布水器、中心管和排水口流出。
硬水经控制器进水口,向下通过中心管、下布水器,然后向上流过树脂层,最后通过排水口流出。
5600 5600SE全自动软化水设备安装、运行及维护手册目录一、产品概述二、工作流程图三、设备的安装和运行四、设备安装示意图五、FLECK5600控制器的调试步骤六、FLECK56SE控制器的调试步骤七、FLECK56SE控制器全面编程及相关代号的意义列表八、故障排除产品概述首先感谢您使用本公司的全自动软化水设备!为着方便您的使用,我们编写了该产品的客户手册,您的认真阅读和理解一定能为产品的良好使用打下基础。
5600系列自动软水器分为时间周期型和流量周期型两种控制方式,用户可以根据当地水质及用户对于水质的要求来进行选择。
本产品广泛应用于蒸汽和热水锅炉、热交换设备、食品加工、造纸印刷、洗衣印染、家庭、宾馆饭店、医疗制药、纯水制备预处理等行业。
我公司将给用户提供完善的技术及售后服务。
自动软水器技术参数:入口水压:0.2Mpa-0.6Mpa 工作温度:2-50℃ 电源型式:220V/50Hz AC 电源功率:3W出口硬度:≤0.03mmol/L再生方式:动态顺流再生或逆流再生 树脂型号:001×7强酸性阳离子交换树脂 盐 耗:<160-240g/mol (根据水质情况)FLECK5600/56SE 控制器工作流程图说明:FLECK5600和56SE 控制器的水流过程略为不同,但原理一致。
1、 工作状态2、预清洗(5min )硬水经控制器进水口流过树脂层,软化后经下布水器、中心管向上流出出水口,此时设备处于工作状态。
硬水经控制器进水口流过树脂层,软化后经下布水器、中心管向上流出排水口,进行预清洗。
3、反洗(10min)4、吸盐(50min)5、慢洗6、快洗硬水经控制器进水口向下流过中心管、下布水器,向上流经树脂层,流出排水口,进行反洗。
硬水经控制器进水口,通过射流器,吸入盐液再生剂,向下流过树脂层进行再生还原,最后通过下布水器、中心管和排水口流出。
吸盐完成后,空气止回阀会将吸盐口封住,防止空气的进入,硬水继续经控制器进水口,通过射流器,向下流过树脂层,最后通过下布水器、中心管和排水口流出。
FLECK5600SE控制器全自动软化水设备操作使用手册北京普瑞特水处理技术开发有限公司FLECK56SE控制器调试步骤一:准备工作和注意事项a、软水设备在调试及运行前应按厂家要求安装完毕进、出水、排污管道和阀门;b、自来水、电源及排水沟准备就绪;c、打开旁通阀,让自来水冲洗管道至出水变清,然后关闭阀门;d、控制器再生程序分别为:1、反洗(Backwash)2、吸盐与慢洗(Brine/Rinse)3、快洗(Rinse)4、盐箱注水(Brine Refill)。
工作指示工作状态—灯亮当天再生—灯闪—灯闪编程模式指示灯正向Up再生反向Down二:调试工作1. 整控制器到工作位置,让水流进树脂罐,当水流停止时,打开阀门以放尽罐中空气,然后关闭阀门;2.插上电源,观察是否工作;3.控制器时间设定,按动Up或Down键可调整时间,连续按住可连续调整;4.控制器简单编程(控制器时间非12:01PM)a.同时按住Up或Down键,5秒后控制器进入编程模式,此时编程指示灯亮,每按一次Extra Cycle键,控制器程序进入下一步程序;b.产水量设定按动Up或Down键可以设定软水器再生前的产水量;c.A Off:流量型专用参数,不得更改。
d.退出编程按动Extra Cycle键,控制器退出编程模式。
5.控制器全面编程按动Up或Down键,将时间设定为12:01PM(必须设定为该时间,才可以进行全部程序内容的调试);然后通过按动Up、Down、Extra Cycle键即可进行对控制器全部程序内容的编程,程序内容及步骤见附表《控制器全面编程及相关代号的意义列表。
》6、软水器即时再生方式按动Extra Cycle键,开始再生程序- - -a、对于即时再生控制器,按动Extra Cycle键后,即开始再生程序;b、对于延时再生控制器,按动Extra Cycl键后,工作状态指示灯开始闪动,控制器将在当日的预先设定时间开始再生程序;c、按住Extra Cycle键5秒钟后,延时再生类型控制器即被强制进入再生程序;7、再生步骤按动Extra Cycle键,控制器进入再生程序(此前,盐箱加满大盐粒,禁用细盐、碘盐、将水加至空气止回阀顶部)a、控制器进入步骤1(RINSE),快洗3-8分钟,按动Extra Cycle键;b、控制器进入步骤2(BACK WASH),反洗1-8分钟,按Extra Cycle健;c、控制器进入步骤3(BRINE/RINSE),吸盐/慢洗2-58分钟,按动Extra Cycle健;d、控制器进入步骤4(REPID RINSE),注水2-11分钟;e、按动Extra Cycle健,控制器返回工作状态。
目录FLECK技术特性 (2)FLECK软化水器配置表 (16)FLECK使用手册(5600、56SE、5000SE) (17)FLECK使用手册(2510、2750、2850、2900、2930、3130、3150、3900) (30)FLECK使用手册(9000、9500) (44)FLECK电子调试手册(3200NT Timer SE Timer) (55)AUTOTROL使用手册..................^ (65)2510技术特性阀体材料Noryl进/出口管径1”流量范围(0.35Mpa进水压力)连续出水量(压降0.1MPa) 4.3m³/h峰值出水量(压降0.175MPa) 5.4m³/h阻力系数Cv 5反洗流量(压降0.175MPa)17gpm再生:顺流/逆流顺流程序调节所有再生步骤时间均可调节最大再生时间164分钟流量计精度3/4 0.056-3.4m³/h±5%流量计量程3/4 标准0.47 –8m³加大 2.3 – 40m³无硬水旁通是主要尺寸:中心管直径 1 "(1.05)O.D排水管直径1/2 " Q.C.盐液管直径3/8"罐体接口直径 2 1/2"-8 Straight Q.C.阀体高度(由阀体顶端至罐体接口)5-1/2使用与软化,多介质沙滤,活性炭过滤,的配置参考注:进水压力为40psi(0.28MPa),再生盐耗为每升树脂160克盐。
电源参数24v、110、220v-50Hz、60Hz 设计压力 2.1MPa工作压力0.14-0.84MPa工作温度34º-110º F工作程序时间参考设置1.反洗10分钟2.吸盐置换60分钟3.正洗10分钟4.盐箱补水10分钟5.运行选项手动水力控制隔膜阀旁通阀微电子控制过滤密封外罩2750技术特性阀体材料无铅黄铜进/出口管径1”流量范围(0.35Mpa进水压力)连续出水量(压降0.1MPa) 5.9m³/h峰值出水量(压降0.175MPa) 7.5m³/h阻力系数Cv 6.8反洗流量(压降0.175MPa)25gpm再生:顺流/逆流任选一项程序调节所有再生步骤时间均可调节最大再生时间164分钟流量计精度1”0.159-9.90m³/h±5%3/4 0.056-3.4m³/h±5%流量计量程1”标准 1.17 –19.96m³3/4 加大 5.87 – 99.81m³标准0.47-8m³加大 2.3-40m³无硬水旁通是主要尺寸:中心管直径 1 "(1.05)O.D排水管直径3/4 " (male).盐液管直径3/8",(1/2”)罐体接口直径 2 1/2"-8.阀体高度(由阀体顶端至罐体接口)6-1/2使用与软化,多介质沙滤,活性炭过滤,的配置参考注:进水压力为40psi(0.28MPa),再生盐耗为每升树脂160克盐。
FLECK 5600 WATER SOFTENER INSTALLATIONDiscount Water Softeners recommends using a licensed plumber to install your water softener. The following installation instructions are for use with the water softener system you now own. Discount Water Softeners assumes no responsibility for improper installation or injury.Additional instructions are also in your water softener manufacturers’ manual on page 3. Skip steps 3 and 4 in the mfg. manual. For SE model use the pink pullout that came with the manufacturers manual for the 5600SE programming guide. Step 1:Location of your softener is important. It should be in a protected dry, level and non-freezing area (34-120 degrees F). The 2 tanks should be set close to each other. The square tank is your salt (brine) tank (for softener salt or potassium chloride) and it is the tank that you will have to refill with salt from time to time, so make it the more accessible of the 2 tanks. Do not put salt in this tank until you have put the softener into service and have tested the cycles.Step 2:You will need a standard outlet that is not controlled by a switch. You should also have a floor drain located nearby.Step 3: The distributor tube or turbulator should be placed in the softener tank with the distributor basket end down. The softener tank (fiberglass construction) is the taller of the two tanks and shown in the following picture. Turn the tube a couple times to make sure that the bottom basket seats properly in the bottom of the tank. Make sure the distributor tube or turbulator is in the tank BEFORE YOU ADD THE RESIN!Step 4:Be sure to place the softener tank shown above where you want to connect it to your water line because it will be heavy a difficult to move after the resin is added. Make sure you install your softener in line before your hot water heater to insure that you have full benefit of the softener system.Step 5:Be sure to cover the open upper end of the distributor tube or turbulator with tape or the cap as shown below to keep any resin from falling into the distributor tube or turbulator tube while pouring the resin into the softener tank. Remove the tapeafter filling the tank with resin.Step 6: Place the funnel into the softener tank as shown below, and slowly pour the resin into the softener tank. Caution: If you purchased a water softener that came with a bag containing gravel, you must add the gravel first before the resin.Step 7: Be careful to keep the distributor tube centered as best you can, while filling. Once the filling of the softener tank is completed,carefully remove the tape or cap from the distributor or turbulator tube.Do not pull upwards on the distributor tube.Step 8: The control valve head can now be screwed onto the softener tank. Be sure the large O-ring is in place, and lubricated. As you start to screw the control valve onto the tank, make sure the hole in the center of the control valve fits over the riser tube or turbulator. The control valve should be hand tightened, snug and tight to eliminate a possible leak, clockwise.OrStep 9:You are now ready to install the bypass valve or yoke to the control valve with the metal tabs on the back of the valve. Be sure to not over tighten the screws that hold on the metal tabs as you can strip out the plastic holes. Turn off main water valve. Water connections to and from softener should now be connected. For Fleck 5600 systems you will need to install your bypass along with either your plastic male threaded connections or stainless steel female threaded fittings. The plastic or stainless steel fittings will need to be screwed on to your existing piping. CAUTION: YOU MUST PAY ATTENTION TO THE IN AND OUT ARROWS ON THEVALVE TO BE SURE THE SOFTENER IS PIPED PROPERLY.You will need a drain for the backwashing cycles. This should be no longer than 20 feet from the water softener. You will need to purchase this flexible 1/2 i.d. plastic pipe (can be vinyl, polyethylene etc. and same size will be used for a brine tank overflow) and a small clamp to hold the tubing over the fitting. This backwashing drain line will be under high pressure when the backwash cycle is working. Make sure the drain line is secured. The drain line will need to drain into a drain, which should be a minimum of 1 1/2” size, and ideally be below the top of the head of your softener. Local codes should be adhered to. (be sure to use teflon tape on this step). Step 11: You will now need to connect the brine tank line to the water softener valve. Attach the clear tubing provided from the brine tank to the connection fitting on the valve on the brass fitting. First attach the brass nut to the tubing then put the fitting inside the tubing. Then screw the tubing and nut to the brass threads on the valve.On the other end, attach the tubing to the brine tank as shown below.On the Fleck 5600 there is a side connection where you will connect the drain line also. There is a hose barb fitting provided to make this connection. This connectionis just to the right of where you just connected the brine tubing line.Note: Never connect the drain line directly into a drain. Allow an air-gap between the drain line and waste line to prevent possibility of back- siphoning.Step 12: INITIAL POWER UP1. Add salt to the salt tank after moving it to the desired spot that is accessible for refill. With a bucket or hose, add approximately 4 to 6 gallons of water to the salt tank.2. Set your bypass in bypass mode and slowly turn on the main water valve to your home until all pipes are pressurized. Now open the bypass valve SLOWLY. You do not want to be surprised by leaks. Let the resin tank fill completely, then open the bypass valves the rest of the way.CAUTION If opened too rapidly or too far, resin may be lost out of the tank into the valve or the plumbing. In the 1/4 open position, you should hear air slowly escaping from the valve drain line.3. Plug the power supply transformer into a socket that is not controlled by a switch or timer.IMPORTANT NOTES BEFORE PROGRAMMING:Make sure you set up your treated water capacity (refer to your manual here) for 90% of your total capacity for reserve water in case you have excessive water uses from time to time. Ex: 32,000 grains x 90% = 29,000 grains.Now take 29,000 and divide it by your actual water hardness to get your treated water capacity Ex: 29,000/20GPG = 1450 gallons of water between regenerations4. Program your water softener. Set the time of day, hardness and capacity if necessary. Here is where you will need to refer your owner's manual for your particular water softener settings and programming.5. Once your softener is programmed advance your controller to manual regeneration. The regeneration process can take a while.6. Check for any leaks during this initial regeneration. Also make sure that there is water in the salt tank after the regeneration is complete.7. After the initial regeneration it is always a good idea to put your water softener into a second manual regeneration to ensure that the salt has dissolved making a full brine solution.8. Your softener should now be providing you with softened water.。