综合布线系统工程预算表
- 格式:xls
- 大小:15.00 KB
- 文档页数:1
【精编推荐】弱电系统总预算表弱电系统总预算表,,,序号,系统名称,品牌,总金额1,综合布线系统,,2,公共广播系统,,3,安全防范系统,,4,有线电视系统,,5,排队叫号系统,,6,病房呼叫系统,,7,公共显示及触摸屏查询系统,,8,一卡通管理系统,,9,婴儿防盗系统,,10,探视对讲系统,,11,数字时钟系统,,12,楼宇自控系统,,13,能源计量系统,,14,手术示教系统,,15,综合管路,,16,总价,,青岛西海岸医疗中心─弱电系统─综合布线系统预算表单位:人民币元序号,产品名称,型号,品牌,单位,数量,单价,金额1,六类非屏蔽模块,,,个,8313,,2,BS双口面板,,,个,2634,,3,BS单口面板,,,个,3045,,4,六类非屏蔽数据跳线(3米),,,条,500,, 5,六类非屏蔽数据跳线(5米),,,条,500,, 6,千兆多模光纤耦合器(双工),,,个,82,, 7,千兆多模光纤尾纤(双工),,,个,82,, 8,千兆多模光纤面板,,,个,82,,9,千兆多模光纤跳线(3米),,,对,82,,小计A,,,,,,二、水平子系统,,,,,,10,六类非屏蔽线缆,,,305米/箱,1900,, 11,2芯室内千兆多模光缆,,,米,8400,,小计B,,,,,,三、垂直子系统,,,,,,12,12芯室内千兆多模光缆,,,米,3480,, 13,12芯室内万兆多模光缆,,,米,3540,, 14,3类25对大对数电缆,,,305米/轴,2,, 15,3类50对大对数电缆,,,305米/轴,3,, 16,3类100对大对数电缆,,,305米/轴,14,, 小计C,,,,,,17,6类24口非屏蔽配线架,,,个,402,,18,封闭式单面理线器,,,个,402,,19,六类非屏蔽模块,,,个,9648,,20,STG10对可开路话音模块(含1-10数字),,,个,539,, 21,10对STG话音模块横向标签支架,,,个,539,, 22,19寸2X10个STG模块背架(3.5U),,,个,67,, 23,语音跳线,,,卷,67,,24,24口光纤配线架,,,个,76,,25,LC光纤耦合器(光配自带),,,个,,,26,LC尾纤(光配自带),,,条,,,27,千兆多模光纤跳线(3米),,,对,277,,28,万兆多模光纤跳线(3米),,,对,100,,29,六类非屏蔽数据跳线(1米),,,条,1000,,30,六类非屏蔽数据跳线(2米),,,条,1000,,小计D,,,,,,五、设备间子系统,,,,,,31,24口光纤配线架,,,个,11,,32,LC光纤耦合器(光配自带),,,个,,,33,LC尾纤(光配自带),,,条,,,34,STG10对可开路话音模块(含1-10数字),,,个,370,, 35,10对STG话音模块横向标签支架,,,个,370,,36,19寸2X10个STG模块背架(3.5U),,,个,20,,37,语音跳线,,,卷,37,,38,万兆多模光纤跳线(3米),,,对,41,,小计E,,,,,,六、IDF间设备及其他辅材,,,,,,39,六类水晶头(RJ45),,,个,2000,,40,端子排模块压接工具,,,把,4,,41,水晶头压接工具,,,套,4,,42,600*60042U机柜(配制风扇隔板及各连接件),,,台,62,, 43,机柜工业连接器,,,个,62,,44,机柜PDU电源,,,个,62,,45,其它材料,,,套,1,,小计G说明:,设备及材料费用合计:,,工程安装费:,,税金:,,总计金额:,青岛西海岸医疗中心─弱电系统─公共广播系统预算表,,,,,,,单位:人民币元序号,产品名称,型号,品牌,单位,数量,单价,金额一、保安消控中心部分,,,,,,1,管理工作站,,,台,1,,2,定时播放软件,,,套,1,,3,AM/FM收音头,,,台,1,,4,带钟声呼叫话筒,,,只,1,,5,控制面板,,,台,1,,6,扩展控制面板,,,台,10,,7,功率放大器(600W),,,台,5,,8,功率放大器(1200W),,,台,5,,9,连接面板,,,台,10,,10,音量衰减控制面板,,,台,10,,11,监听面板(10路),,,台,10,,12,矩阵控制面板,,,台,1,,13,直流供电面板,,,台,3,,14,音量控制器(30W),,,只,2,,15,音量控制器(60W),,,只,25,,16,音量控制器(120W),,,只,27,,17,音量控制器(200W),,,只,5,,18,草坪音箱(30W),,,只,30,,19,标准机柜(600*60042U),,,台,3,, 小计A,,,,,,二、手术区部分,,,,,,20,管理工作站,,,台,1,,21,定时播放软件,,,套,1,,22,AM/FM收音头,,,台,1,,23,带钟声呼叫话筒,,,只,1,,24,控制面板,,,台,1,,25,功率放大器(600W),,,台,1,, 26,连接面板,,,台,1,,27,直流供电面板,,,台,1,,28,音量控制器(30W),,,只,21,, 29,喇叭(3W),,,只,35,,小计B,,,,,,三、线缆部分,,,,,,30,RVS2*1.5,,,米,14500,,小计C,,,,,,说明:,设备及材料费用合计:,,工程安装费:,,税金:,,总计金额:,青岛西海岸医疗中心─弱电系统─安全防范系统预算表单位:人民币元序号,产品名称,型号,品牌,单位,数量,单价,金额一、闭路电视监控系统,,,,,,a)前端部分,,,,,,1,室内一体化快球摄像机(含护罩),,,套,3,,2,室外一体化快球摄像机(含护罩),,,套,3,,3,彩色固定枪式摄像机,,,台,156,,4,3.5~8mm手动变焦自动光圈镜头,,,只,156,,5,铝合金支架,,,只,116,,6,室外立杆,,,个,43,,7,彩色半球摄像机,,,台,538,,8,电梯摄像机,,,台,35,,9,监控专用电源AC24V/3A,,,只,4,,10,监控专用电源DC12V/5A,,,只,165,,11,拾音器,,,个,39,,12,电源放置箱,,,只,26,,小计A,,,,,,b)传输部分,,,,,,13,视频信号线(SYV-75-5),,,米,58500,,14,控制信号线(RVVP3*1.0),,,米,1300,,15,电源线(RVV2*1.0),,,米,58500,,16,拾音器信号线(RVVP4*0.75),,,米,2350,,小计B,,,,,,c)控制部分,,,,,,1)管理中心设备,,,,,,17,4路网络视频解码器,,,台,7,,18,视频管理服务器(含客户端软件),,,套,1,,19,视频管理客户端软件(每增加10个客户端授权费用),,,套,2,,20,视频管理服务器软件(每增加10路视频授权费用),,,套,2,,21,视频管理服务器软件(每增加100路视频授权费用),,,套,6,,22,数据管理服务器软件(每增加1台IP-SAN存储设备授权费用),,,套,9,, 23,以太网交换机主机,,,台,1,,24,交流电源模块,1400W,,,个,2,,25,交换路由引擎,,,只,1,,26,以太网电接口模块(RJ45),,,个,1,,27,以太网光接口模块(SFP,LC),,,个,1,,28,光模块-SFP-GE-多模模块,,,个,6,,29,256M工业级CF卡,,,个,1,,2)室外监控接入部分,,,,,,30,16路H.264网络视频编码器,,,台,6,,31,网络存储主机,,,只,1,,32,网络存储700W电源模块,,,只,1,,33,一体化SATA硬盘(1000G),,,只,16,,34,EX系列首次安装服务,,,项,1,,35,24口以太网交换机主机,,,台,1,,3)一区监控接入部分,,,,,,36,16路H.264网络视频编码器,,,台,12,, 37,网络存储主机,,,台,1,,38,网络存储扩展磁盘柜,,,只,1,,39,网络存储700W电源模块,,,只,2,, 40,一体化SATA硬盘(1000G),,,只,24,, 41,EX系列首次安装服务,,,项,1,,42,24口太网交换机主机,,,台,1,,43,光模块-SFP-GE-多模模块,,,个,1,, 4)二区监控接入部分,,,,,,44,16路H.264网络视频编码器,,,台,17,, 45,网络存储主机,,,台,1,,46,网络存储扩展磁盘柜,,,只,1,,47,网络存储700W电源模块,,,只,2,, 48,一体化SATA硬盘(1000G),,,只,32,, 49,EX系列首次安装服务,,,项,1,,50,24口太网交换机主机,,,台,1,,51,光模块-SFP-GE-多模模块,,,个,1,, 5)三区监控接入部分,,,,,,52,16路H.264网络视频编码器,,,台,13,,53,网络存储主机,,,台,1,,54,网络存储扩展磁盘柜,,,只,1,,55,网络存储700W电源模块,,,只,2,, 56,一体化SATA硬盘(1000G),,,只,28,, 57,EX系列首次安装服务,,,项,2,,58,48口太网交换机主机,,,台,1,,59,24口太网交换机主机,,,台,1,,60,光模块-SFP-GE-多模模块,,,个,2,, 6)四区监控接入部分,,,,,,61,16路H.264网络视频编码器,,,台,9,, 62,网络存储主机,,,台,1,,63,网络存储扩展磁盘柜,,,只,1,,64,网络存储700W电源模块,,,只,2,, 65,一体化SATA硬盘(1000G),,,只,20,, 66,EX系列首次安装服务,,,项,1,,67,24口太网交换机主机,,,台,1,,68,光模块-SFP-GE-多模模块,,,个,1,, 7)五区监控接入部分,,,,,,69,16路H.264网络视频编码器,,,台,28,, 70,网络存储主机,,,台,2,,71,网络存储扩展磁盘柜,,,只,1,,72,网络存储700W电源模块,,,只,3,,73,一体化SATA硬盘(1000G),,,只,40,, 74,EX系列首次安装服务,,,项,2,,75,24口太网交换机主机,,,台,1,,76,48口太网交换机主机,,,台,1,,77,光模块-SFP-GE-多模模块,,,个,2,, 8)六区监控接入部分,,,,,,78,16路H.264网络视频编码器,,,台,1,, 9)七区监控接入部分,,,,,,79,16路H.264网络视频编码器,,,台,19,, 80,网络存储主机,,,台,2,,81,网络存储扩展磁盘柜,,,只,1,,82,网络存储700W电源模块,,,只,3,, 83,一体化SATA硬盘(1000G),,,只,38,, 84,EX系列首次安装服务,,,项,2,,85,24口太网交换机主机,,,台,1,,86,48口太网交换机主机,,,台,1,,87,光模块-SFP-GE-多模模块,,,个,2,,小计C,,,,,,d)管理及显示部分,,,,,,88,19寸平板电视,,,台,24,,89,42寸平板电视,,,台,2,,90,电视墙安装支架,,,套,1,,91,双联琴式操作台,,,套,1,,92,五轮转椅,,,把,6,,93,管理工作站,,,台,1,,小计D,,,,,,二、防盗报警系统,,,,,,94,手动报警按钮,,,只,157,,95,报警主机,,,台,1,,96,可编程主控键盘,,,块,1,,97,主机串行打印机接口模块,,,只,1,,98,单防区扩展模块,,,块,9,,99,2防区扩展模块,,,块,19,,100,8防区扩展模块,,,块,14,,101,增强型总线延伸模块,,,块,1,,102,32路电子地图接口模块,,,块,1,,103,主机网络接口模块,,,套,1,,104,带闪灯警号,,,只,1,,105,主机用蓄电池,,,只,1,,106,报警线(RVV2*1.0),,,米,13000,,107,报警管理软件,,,套,1,,108,报警模块放置箱(200*100*100),,,只,34,, 小计E,,,,,,三、残卫求助呼叫系统,,,,,,109,求助面板,,,只,27,,110,复位开关面板,,,只,27,,111,声光报警装置,,,只,27,,112,控制器,,,只,27,,113,中控显示系统,,,只,1,,114,系统控制线RVS2*1.0,,,米,600,,115,主干控制线RVV2*1.0,,,米,900,,小计F,,,,,,四、离线巡更系统,,116,信息采集器,,,台,12,,117,无线通讯座,,,台,3,,118,标识牌,,,块,148,,119,钥匙型人名钮,,,只,12,,120,事件本,,,台,12,,121,打印机,,,台,1,,122,信息钮,,,只,148,,123,中文管理软件,,,套,1,,小计G,,,,,,五、其他,,124,附件,,,批,1,,说明:报警、电子巡更、安防系统服务器共用一台,电源放置箱尺寸与闭路电视监控系统图对应的摄像机电源数量配套。
综合布线报价清单
举例:某工厂有三幢建筑群(办公楼、厂房、研发楼),办公楼分两个机房(四楼为主管理机房、
分管理机房、研发楼有一个分管理机房。
总共有967个语音数据信息点,办公楼三、四楼(59电话、10传真、194个网、二楼机房(258电话、18传真、233个网络),厂房机房(32个电话、1传真、30个网络),研发楼机房(7个电话、机房与机房之间通过六芯的光纤连接。
平均每个语音数据信息线的长度为50米,语音主干采用100对电缆连接。
配置96系统报价。
机房、二楼为分管理机房)、厂房有一个、四楼(59电话、10传真、194个网络),办公楼一个网络),研发楼机房(7个电话、125个网络),语音主干采用100对电缆连接。
配置967点的综合布线。