led线条灯说明书
- 格式:docx
- 大小:732.07 KB
- 文档页数:2
产品型号:
本安装说明适用于LED户外硬条灯ELC403-03系列、ELC405-06MT系列、ELC410-12系列。
注意事项:
1.安装前请仔细阅读说明书;
2.请专业电工安装;
3.为避免触电危险,在安装、维护前请确认关闭电源;
4.安装灯具前请确认安装面牢固可靠,以避免灯具坠落;
5.保留说明书,以备使用参考。
安装方法及步骤:
1.此款线条灯的安装方式,先固定U形不锈钢支架;一根灯条需用2个支架;支架的固定孔位见图1;注:自攻螺丝
和塑胶壁虎施工方自备;
2.灯条由灯身上安装好的安装支架,通过长螺栓与螺母安装在U形支架上,见图3;安装好后如图4所示,锁紧螺母
可进行定位,拧松螺母,可进行调角;
3.安装邻近的灯条,需先接线再卡入U形支架;如图5,灯具有信号进和出的方向,请按照线材上的标贴指示接线。
由“WAC”“”商标持有人美国 WAC Lighting 公司授权
中国营销总部:华格照明灯具(上海)有限公司
4、灯具接线按照如下示意图:
备注:
电源线、信号线的连接使用我司提供的防水接头线连接;
建议4-6米灯具一个变压器电源回路;
灯具由分控端口接入灯具前,加入一个信号放大器;然后每16米灯具加进一个信号放大器;
主控器、分控器的用法参见主控和分控的说明书。
由“WAC”“”商标持有人美国 WAC Lighting 公司授权
中国营销总部:华格照明灯具(上海)有限公司。
3.0x2.5mm SURFACE MOUNT LED LAMP Features3. The specifications, characteristics and technical data described in the datasheet are subject to change without prior notice.Selection GuideNotes:1. θ1/2 is the angle from optical centerline where the luminous intensity is 1/2 of the optical peak value.2. Luminous intensity/ luminous Flux: +/-15%.Part No.DiceLens TypeIv (mcd) [2] @ 20mA Viewing Angle [1] Code. Min. Max. 2θ1/2 APB3025CGKQWDF-AMTGreen (AlGaInP)Yellow FluorescentF 20 40120° G 40 55 M 80 120 P 200 300Q 300 400 R 400 500White (InGaN)H 55 80 Absolute Maximum Ratings at TA=25°CParameterSymbolValueUnitGreenWhitePower dissipation P d 75 80 mW Operating Temperature Top -40 To+ 100 °C Storage Temperature Tstg°C Junction temperatureT J 120 110 °C DC Forward Current (TA=25°C) I F 30 20 mA Peak Forward Current [1] (TA=25°C) I FM 150 150 mAReverse Voltage (TA=25°C)V R55 VElectrostatic Discharge Threshold (HBM)3000 250 V -40 To+ 110Thermal resistance 1chip on (typ.)(Junction/solder point) 2 chip on (typ.)1 chip on (max.)2 chip on (max.) 220330 256 410220 330 256 410°C/WR th j-s R th j-s R th j-s [2]R th j-s [2] Note:1.1/10 Duty Cycle, 0.1ms Pulse Width.2.Rth(max) is based on statistic values.Electrical / Optical Characteristics at TA=25°C (Green)Parameter SymbolValueUnit Code. Min.Typ.Max.Wavelength at peak emission I F=20mA λpeak 574 nmDominant Wavelength I F=20mA λ dom [1] 3 563 5654 565 5675 567 5696 569 571Spectral bandwidth at 50%ΦREL MAX I F=20mA Δλ20 nm Forward Voltage I F=20mA V F [2] 2.1 2.5 VReverse Current (V R = 5V) I R10 uATemperature coefficient of λpeakI F=20mA, -10°C≤T≤100°CTCλpeak 0.06 nm/°C Temperature coefficient of λdomI F=20mA, -10°C≤T≤100°CTCλdom 0.03 nm/°CTemperature coefficient of V FI F=20mA, -10°C≤T≤100°C TC V-3.6 mV/°CnmNotes:1.The dominant Wavelength (λ d) above is the setup value of the sorting machine. (Tolerance λ d : ±1nm. )2. Forward Voltage: +/-0.1V.Electrical / Optical Characteristics at TA=25°C (White)Parameter Symbol Value Unit Chromaticity coordinate x acc.to CIE1931I F=20mA [Typ.]x [1] 0.31Chromaticity coordinate y acc.to CIE1931I F=20mA [Typ.]y [1] 0.31Forward Voltage I F=20mA [Min.]V F [2]-VForward Voltage I F=20mA [Typ.] 3.3Forward Voltage I F=20mA [Max.] 4.0Temperature coefficient of V FI F=20mA, -10°C≤T≤100°C [Typ.]TC V-2.5 mV/°C Temperature coefficient of xI F=20mA, -10°C≤T≤100°C [Typ.]TC X-0.1 10-3/°CTemperature coefficient of yI F=20mA, -10°C≤T≤100°C [Typ.] TC y-0.2 10-3/°CReverse Current (V R = 5V) [Max.] I R50 uA Notes:1.Measurement tolerance of the chromaticity coordinates is ±0.01.2.Forward Voltage: +/-0.1V.Reliability Test Items And ConditionsThe reliability of products shall be satisfied with items listed below Lot Tolerance Percent Defective (LTPD) : 10%No. Test Item Standards Test Condition Test Times /CyclesNumber ofDamaged1 Continuous operating test - Ta =25°C ,IF = maximum rated current* 1,000 h 0 / 222 High Temp. operating test EIAJ ED-4701/100(101)Ta = 100°C IF = maximum rated current* 1,000 h 0 / 223 Low Temp. operating test - Ta = -40°C, IF = maximum rated current* 1,000 h 0 / 224 High temp. storage test EIAJ ED-4701/100(201)Ta = maximum rated storage temperature 1,000 h 0 / 225 Low temp. storage test EIAJ ED-4701/100(202)Ta = -40°C 1,000 h 0 / 226 High temp. & humidity storage test EIAJ ED-4701/100(103)Ta = 60°C, RH = 90% 1,000 h 0 / 227 High temp. & humidity operating test EIAJ ED-4701/100(102)Ta = 60°C, RH = 90%IF = maximum rated current*1,000 h 0 / 228 Soldering reliability test EIAJ ED-4701/100(301)Moisture soak : 30°C,70% RH, 72hPreheat : 150~180°C(120s max.)Soldering temp : 260°C(10s)3 times 0 / 189 Thermal shock operating test - Ta = -40°C(15min) ~ 100°C(15min)IF = derated current at 100°C1,000 cycles 0 / 2210 Thermal shock test - Ta = -40°C(15min) ~ maximum ratedstorage temperature(15min)1,000 cycles 0 / 2211 Electric Static Discharge (ESD) EIAJ ED-4701/100(304)C = 100pF , R2 = 1.5KΩV=3000V(Green)V=250V(White)Once eachPolarity0 / 2212 Vibration test - a = 196m/s² , f = 100~2KHz ,t = 48min for all xyz axes4 times 0 / 22* : Refer to forward current vs. derating curve diagramItems Symbols Conditions Failure Criterialuminous Intensity lv I F = 20mA Testing Min. Value <Spec.Min.Value x 0.5 Forward Voltage V F I F = 20mA Testing Max. Value ≥Spec.Max.Value x 1.2 Reverse Current I R V R = Maximum Rated Reverse Voltage Testing Max. Value ≥Spec.Max.Value x 2.5High temp. storage test - - Occurrence of notable decoloration, deformation and crackingFailure Criteria。
L11产品规格书产品概述应用环境:室内、户外产品尺寸图(单位:mm)L11线条灯是专为户外景观亮化设计的一款小功率LED 条形产品。
采用航空级6063挤压铝外壳,阻燃塑胶PC端盖,通过高导热耐候PU胶灌封防水;灯条体积小,外观精致;灯条间通过国标定制柔性线缆连接;产品长度、顔色可定制,能适应大曲线或曲面的安装;适用于建筑物立面轮廓勾边,内外表面装饰亮化。
产品特点:★新一代T T L串行技术设计★标准D M X512控制协议★行业领先的无线扣式防拽连接设计★高导热胶全灌封防水设计★户外防雷及静电(E S D)专用防护设计★产品的上盖可选:支持P C透明或乳白弧盖★产品采用独创的隐藏式安装滑块★支持R G B/W电流单独可调(低亮高灰)技术参数产品选型表基 本 参 数 色 彩/灰 度 RGB/W 各256级灰度; 光 源 类 型 3535 /5050 /2835 光 源 数 量48-72pcs/米 (0.25米-1米,长度可以按要求定制)材 质 铝喷涂外壳 / 阳极氧化 + 光学PC 罩寿 命 50,000h 重 量 710g/米 光 电 参 数 工 作 电 压 DC24V最 大 功 率 12-20W/米 RGB 光 强 180cd/米白 光 360cd/米 光 束 角 30° / 45° / 60° / 90° / 120°电 气 等 级 III 类其 它 参 数 工 作 温 度 -20°C to 50°C 储 存 温 度 -40°C to 70°C 防 护 等 级IP66配光曲线规格型号 光源 数量 光源类型 颜色控制类型 DC 工作电压 功率 白色 光强 DA028-48AT 48PCS 3535 RGB/W 单线串行TTL 24V 12W 120cd DA028-48AD 48PCS 3535 RGB/W DMX512 24V 12W 120cd DA028-48XD 48PCS 5050 RGBW DMX512 24V 15W 180cd DA028-48CN 48PCS 3535 2835 W 无控制 24V 12W 240cd DA028-60AT 60PCS 3535 RGB/W 单线串行TTL 24Vz 15W 150cd DA028-60AD 60PCS 3535 RGB/W DMX512 24V 15W 150cd DA028-60XD 60PCS 5050 RGBW DMX512 24V 20W 225cd DA028-60CN 60PCS 3535 2835 W 无控制 24V 15W 300cd DA028-72AT 72PCS 3535 RGB/W 单线串行TTL 24V 18W 180cd DA028-72AD 72PCS 3535 RGB/W DMX512 24V 18W 180cd DA028-72CN72PCS3535 2835W无控制24V18W360cd安装件外观尺寸安装底座尺寸图(单位mm);固定式安装底座安装方式示意:①安装载体钻孔,装膨胀胶塞:在载体上按灯具安装位置做好记号,并钻孔(建议用6mm钻头);把膨胀胶塞用锤子敲入钻孔里(注:胶塞不可松动);②固定灯具安装底座:将灯具安装底座孔位对准膨胀胶塞孔,选用合适的自攻螺丝将灯具安装底座固定到安装载体上;③灯具安装:将灯具对准灯具安装底座,并扣到灯具安装底座上;④灯具加固,完成安装:装好灯具后,从侧下边打两个自攻螺丝将型材上盖与型材安装底座固定在一起,防止型材上盖坠落。
DR-200-A产品规格书
产品编号:DR-200-A
规格:72×118×38
工作电压:DC12-24V
功率: 720W
外壳材质: 金属喷漆
概况说明:
DR-200-A配备了多种的变光程序可供用户选择,产品应用的核心电子元件全部采用国外原厂封装,安全稳定,
发热量极低。
LED变光方式采用PWM方式,达到256灰度级,使得变化效果更为细腻。
本产品属于相对同步控制器,每8个小时将会误差1-2秒的时间。
只有单路RGB输出端口。
可拖带的光源:LED模组,LED灯条,LED
灯带,LED灯管。
最多可拖带常规96珠灯板70米或9珠模组1000个。
配有先进的短路自恢复功能、电源正负极接错时自动纠错功能、过载保护功能。
拨码开关:
1、当开关按钮拨到ON方向时为打开状态,反之为关闭状态(OFF)。
2、拨码开关的1-5号位用于调节变化速度,共有5级速度:第1位最快,第5位最慢,依此类推。
1次
只能打开1个位号才有效,当同时打开2个及以上或全部关闭时,系统将默认为1号位的速度。
3、拨码开关的6-8号位用于变化模式的选择,以RGB灯为例,具体操作方式请参照下表:
联系人:158****5888方敏
接口示意图:。
©2002 Whelen Engineering Company Inc.Form No.13702F (053007)A u t o m o t i v e : For warranty information regarding this product, visit /warranty•Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.•Whelen Engineering requires the use of waterproof butt splices and/or connectors if that connector could be exposed to moisture.•Any holes, either created or utilized by this product, should be made both air- and watertight using a sealant recommended by your vehicle manufacturer.•Failure to use specified installation parts and/or hardware will void the product warranty.•If mounting this product requires drilling holes, the installer MUST be sure that no vehicle components or other vital parts could be damaged by the drilling process. Check both sides of the mounting surface before drilling begins. Also de-burr the holes and remove any metal shards or remnants. Install grommets into all wire passage holes.•If this manual states that this product may be mounted with suction cups, magnets, tape or Velcro®, clean the mounting surface with a 50/50 mix of isopropyl alcohol and water and dry thoroughly.•Do not install this product or route any wires in the deployment area of your air bag. Equipment mounted or located in the air bag deployment area will damage or reduce the effectiveness of the air bag, or become a projectile that could cause serious personal injury or death. Refer to your vehicle owner’s manual for the air bag deployment area. The User/Installer assumes full responsibility to determine proper mounting location, based on providing ultimate safety to all passengers inside the vehicle.•For this product to operate at optimum efficiency, a good electrical connection to chassis ground must be made. The recommendedprocedure requires the product ground wire to be connected directly to the NEGATIVE (-) battery post (this does not include products that use cigar power cords).•If this product uses a remote device for activation or control, make sure that this device is located in an area that allows both the vehicle and the device to be operated safely in any driving condition.•Do not attempt to activate or control this device in a hazardous driving situation.•This product contains either strobe light(s), halogen light(s), high-intensity LEDs or a combination of these lights. Do not stare directly into these lights. Momentary blindness and/or eye damage could result.•Use only soap and water to clean the outer lens. Use of other chemicals could result in premature lens cracking (crazing) and discoloration. Lenses in this condition have significantly reduced effectiveness and should be replaced immediately. Inspect and operate this product regularly to confirm its proper operation and mounting condition. Do not use a pressure washer to clean this product.•It is recommended that these instructions be stored in a safe place and referred to when performing maintenance and/or reinstallation of this product.•FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT OR VEHICLE AND/OR SERIOUS INJURY TO YOU AND YOUR PASSENGERS!Warnings to InstallersWhelen’s emergency vehicle warning devices must be properly mounted and wired in order to be effective and safe. Read and follow all of Whelen’s written instructions when installing or using this device. Emergency vehicles are often operated under high speed stressful conditions which must be accounted for when installing all emergency warning devices. Controls should be placed within convenient reach of the operator so that they can operate the system without taking their eyes off the roadway. Emergency warning devices can require high electrical voltages and/or currents. Properly protect and use caution around live electrical connections.Grounding or shorting of electrical connections can cause high current arcing, which can cause personal injury and/or vehicle damage, including fire. Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference. Therefore, after installation of any electronic device it is necessary to test all electronic equipment simultaneously to insure that they operate free of interference from other components within the vehicle. Never power emergency warning equipment from the same circuit or share the same grounding circuit with radio communication equipment. All devices should be mounted in accordance with the manufacturer’s instructions and securely fastened to vehicle elements of sufficient strength to withstand the forces applied to the device. Driver and/or passenger air bags (SRS) will affect the way equipment should be mounted. This device should be mounted by permanent installation and within the zones specified by the vehicle manufacturer, if any. Any device mounted in the deployment area of an air bag will damage or reduce the effectiveness of the air bag and may damage or dislodge the device. Installer must be sure that this device, its mounting hardware and electrical supply wiring does not interfere with the air bag or the SRS wiring or sensors. Mounting the unit inside the vehicle by a method other than permanent installation is not recommended as unit may become dislodged during swerving; sudden braking or collision. Failure to follow instructions can result in personal injury. Whelen assumes no liability for any loss resulting from the use of this warning device. PROPER INSTALLATION COMBINED WITH OPERATOR TRAINING IN THE PROPER USE OF EMERGENCY WARNING DEVICES IS ESSENTIAL TO INSURE THE SAFETY OF EMERGENCY PERSONNEL AND THE PUBLIC.Warnings to UsersWhelen’s emergency vehicle warning devices are intended to alert other operators and pedestrians to the presence and operation of emergency vehicles and personnel. However, the use of this or any other Whelen emergency warning device does not guarantee that you will have the right-of-way or that other drivers and pedestrians will properly heed an emergency warning signal. Never assume you have the right-of-way. It is your responsibility to proceed safely before entering an intersection, driving against traffic, responding at a high rate of speed, or walking on or around traffic lanes. Emergency vehicle warning devices should be tested on a daily basis to ensure that they operate properly. When in actual use, the operator must ensure that both visual and audible warnings are not blocked by vehicle components (i.e.: open trunks or compartment doors), people, vehicles, or other obstructions. It is the user’s responsibility to understand and obey all laws regarding emergency warning devices. The user should be familiar with all applicable laws and regulations prior to the use of any emergency vehicle warning device. Whelen’s audible warning devices are designed to project sound in a forward direction away from the vehicle occupants. However, because sustained periodic exposure to loud sounds can cause hearing loss, all audible warning devices should be installed and operated in accordance with the standards established by the National Fire Protection Association.Safety FirstThis document provides all the necessary information to allow your Whelen product to be properly and safely installed. Before beginning the installation and/or operation of your new product, the installation technician and operator must read this manual completely. Important information is contained herein that could prevent serious injury or damage.Installation Guide:Liberty™ LC Lightbar51 Winthrop RoadChester, Connecticut 06412-0684Phone: (860) 526-9504Internet: Salese-mail:*******************CustomerServicee-mail:*******************®ENGINEERING COMPANY INC.Scan-Lock™ / White-VioletTO CYCLE FORWARD THROUGH ALL PATTERNS: Activate the function you wish to change the flash pattern on, (Takedowns, alley lights etc...) and apply +12 volts to the Scan-Lock™ wire (WHITE-VIOLET) for less than 1 second and release. This will change the pattern. Repeat to go to next pattern.TO CHOOSE A PATTERN: While cycling through the patterns, when you find the pattern you want let it run for more than 5 seconds and it will lock in and become the default pattern.TO RESET TO THE FACTORY DEFAULT PATTERN: Turn off the function (Takedowns, alley lights etc...) you want to reset, apply +12 volts to the Scan-lock™wire then turn the function back on.Available Flash Patterns:SignalAlert™ 75 Alternating (default setting) / CometFlash® 75 Alternating / DoubleFlash 150 Alternating / DoubleFlash 75 Alternating / SingleFlash 375 Alternating / SingleFlash 150 Alternating / SingleFlash 75 Alternating / ActionFlash™ 75 Alternating / ModuFlash™ 75 Alternating / CalFlash™ Single 75 driver Steady / Steady / ActionScan™Traffic Advisor Patterns: Sequence to Solid (default setting) / Sequence On-Sequence Off / Single Lamp: Sequence On to TripleFlash™ / Two Lamp: Sequence On to TripleFlash™Troubleshooting:Your Lightbar should now be fully operational. If it is not functioning properly, check your connections for the following:1.The positive wire (RED) is properly connected to the battery, by way of the user supplied fuse block2. A working fuse of the correct amperage (20 amp) is installed in the fuse block.3.The ground wire (BLACK) is properly connected to the factory ground.If all of these connections are good, contact your Whelen representative for further assistance.1 - GREEN. . . . . . . . . In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . . FRONT CORNER LED’s2 - BLUE . . . . . . . . . . In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . . REAR CORNER LED’s3 - GREEN-WHITE . . In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . . FRONT OUTBOARD LED’s.4 - BLUE-WHITE. . . . In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . . REAR OUTBOARD LED’s5 - GREEN-BLACK. . In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . . FRONT INBOARD LED’s6 - BLUE-BLACK . . . In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . . REAR INBOARD LED’s7 - WHITE-GREEN . . In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . . The RIGHT TA’s8 - WHITE-BLUE. . . . In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . . FLASHING ALLEY & TAKEDOWNS9 - YELLOW . . . . . . . In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . . PASSENGER-SIDE ALLEY LIGHTS 10 - WHITE. . . . . . . . .In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . .DRIVER-SIDE ALLEY LIGHTS11 - WHITE-BLACK. .In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . .TAKE-DOWN LIGHTS12 - WHITE-ORANGE In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . .AUXILIARY / CRUISE LIGHTS13 - WHITE-YELLOW In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . .The LEFT TA’s14 - WHITE-BROWN .In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . .REAR CENTER LED’s15 - VIOLET . . . . . . . .Low Power (See page 1)16 - WHITE-VIOLET. .Scan-Lock™ (See page 1)17 - WHITE-RED . . . .In factory default configuration, this wire activates: . . . . . . . . . . . . . . . . . .FRONT CENTER LED’sNONE . . . . . . . . .The RFI shield drain wire is connected to groundControl Cable:1.RED - Provides power for all strobe lamps. Connect to POSITIVE batteryterminal (12 VDC) and fuse @ 30 amps AT THE BATTERY2.BLACK - Provides ground for all strobe lamps Connect to chassisground.3.NONE - RFI shield drain. Connect to chassis groundPower Cable:NOTE:WHITE-GREEN&WHITE-YELLOW = Split TALiberty Lightbar Wiring。
Leat is the latest linear LED lighting system from Eaton. With an innovative uniform construction, clean minimalist lines and high efficiency, Leatprovides a new alternative for conventional general lighting applications and to emphasize spaces. Simple installation is a key benefit, thanks to the positive coupled connector system which ensures tight true lines are achieved.Available in an Opaline acrylic diffuser gives an evenly lit appearance across the whole face.Emergency operation is integral to 1 metrevariants as an option, making for a seamless visual integration.LeatIP20W AR R A NT YWA R R A NT YYEAR• Suitable for recessed, surface and suspendedapplications• High efficacies of up to 122 Llm/cW whichexceeds the requirements of UK BuildingRegulations: Part L and Section 6 (Scotland)• Three preset lumen output options per length –total design freedom• Close colour tolerance: MacAdam 3 SDCM • 3 hour maintained emergency versions availablein the 1 metre modules• Ideal for stand alone and continuous applications461Body• The strength and accuracy of Leat comes from the precision manufacture of its extruded body. For continuous installation, the dedicated three axis coupled connector system ensures no deviation about the X, Y and Z axis.• Continuous and standalone models usethe same channelled extrusion, reducing complexity and allowing for a coordinated look to a space where mixed applications arerequired.Ceiling integration• For recessing applications where a definededge is required, the trim kits provide a simplesolution. Available in up to 3 metre lengths, itcan provide a seamless finish.• Solid ceilings and plasterboard finishes areaccommodated with dedicated fixing brackets.LED and Drivers• Dedicated PCB’s designed exclusively forLeat give a closely defined continuous lighteffect, negating the ‘dark spot’ joint effect inconventional systems. Continuous variantsinclude through wiring for simple and positiveinterconnection.• A choice of three outputs per length allowfor total design freedom and preciselighting effect, matched to the installationsenvironment.• Continuous runs should not mix outputs as thismay lead to a variance in perceived luminancebetween sections.Diffuser• The flexible Polycarbonate diffuser is availableto suit preset lengths of 1 metre, 1.5 metre, 2metre and 3 metre to suit use in continuoustype installations. In addition a 10 metrecontinuous roll is available to give a trulyseamless lit effect over long runs.• Standalone models come complete withdiffusers and end caps fitted.Construction4711. Insert coupled connector plates2. Join sections together and secure coupled connector plates3. Insert integrated gear trays and connect electrically4. Install diffuserConstructionLeat continuous is simple to install, a coupled connector aligns sections accurately and consistently to create a precision installation. With the flexibility to have installations with incremental lengths of 500mm, Leat gives uniform lighting realization for many applications.Installation Options RecessedSurfaceSuspendedSuspended kit481High Output≈ 3000 Lumen / Linear metreLow Output≈ 1500 Lumen / Linear metreMedium Output≈ 2200 Lumen / Linear metreDesign freedom• Leat is available in a choice of three lumen outputs per unitlength, allowing for the most energy efficient choices to be made within the design process. All Leat models are also available with DALI control gear to offer ultimate light volume and effect in the control of the space.• The three output settings are designed to allow multiple length selections to be made on one or series of configurations. Each maintain the same lumen output per metre, giving a uniform effect and appearance across the array.PerformancePart No.LengthLumen output (lm)Wattage (W)Efficacy (Llm/cW)Low outputLEAC10154KZ 1000153112.9118.7LEAC15224KZ 1500238221.4111.3LEAC20304KZ 2000315226.7118.1LEAC30454KZ3000481139.4122.1Medium outputLEAC10224KZ 1000229719.6117.2LEAC15334KZ 1500333129.6112.5LEAC20444KZ 2000443238.9113.9LEAC30664KZ3000676058.2116.2High outputLEAC10304KZ 1000303326.7113.6LEAC15454KZ 1500458442.9106.9LEAC20604KZ 2000603554.6110.5LEAC30904KZ3000921181.4113.2Note: Continuous runs should not mix outputs as this may lead to a variance in perceived luminance between sections.LIGHTING SOLUTIONS 491Light Engine and Control Gear Options• High output, high efficacy LED chip set optimised forrecessed panel options• Close pitched PCB ensures homogenous continuous effect • Energy efficient fixed output control gear as standard• Dimming option - DALIMaterials• Body – Aluminium extrusion coated in RAL9016 - 60% gloss finish• Diffuser optic - Polycarbonate UV stable Opaline high transmission flexible diffuser• Internal reflector – Steel construction, powder coated in RAL9016 white finish its provide a simple solution. Available in up to 3 metre lengths, it can provide a seamless finish.• Solid ceilings and plasterboard finishes are accommodated with dedicated fixing brackets.Installation Notes• Suitable for recessed, surface and suspended applications • Suitable for exposed ‘T’ ceilings using the trim accessories, stand alone and continuous applications• Appropriate for Plasterboard and solid ceilings using the accessories• Suitable for installation in pendant applications using the suspension accessories• Emergency variants are fused as standardOptions• Fully integral LED emergency conversion, 3 hour duration • CGLine+ self-test emergency versions available, reducing maintenance costs and offering ease of compliance with testing requirements• We offer a range of product support contracts to aid commissioning, reduce your maintenance costs, comply with legislative test requirements and increase the lifespan of your lighting equipmentSpecificationTo specify state: Modular back-lit LED luminaire, of aluminium extrusion construction with post coat powder paint, RAL9016 finish, for lay-in installations, solid ceilings and other applications with Opaline Polycarbonate high transmission diffuser and high efficiency LED modules. LED emergency option via integral conversion as Eaton’s Leat range part no_________Cat no: LEAC20444KZ.LDTSHRnom : 1.25 SHRmax : 1.401Photometric DataDimensionsUtilisation factors / TM5Reflectances Room indexC W F0.7511.251.52 2.53450.70.50.2586875818893961011040.70.30.250616874828791971000.70.10.24555636977838793970.50.50.25666737885899397990.50.30.24959677280858994970.50.1 0.24454626775818591940.30.50.25564717582868993960.30.30.24958657178828690930.30.10.2445461667479838891000425158637175798487BZ-class544444444Note:for Continuous installs, add 6mm to the overalllength to give allowance for the end capsL (mm)H (mm)W (mm)Standalone100010067555150015067555200020067555300030067555Rec essed T rim100010308079150015308079200020308079300030308079Continuous10001000100055150015001500552000200020005530003000300055For more information on the installation requirements and productspecifications, please visit our website: https:///content/gb/en/products/product-catalog/Leat-recessed-LED-ceiling-lights.htmlSee page 468 for design guide 501Catalogue Numbers1Part No.Description Weight (Kg) Continuous Continuous Fixed OutputLow output LEAC10154KZ Leat Continuous 1 metre,1500lm Fixed Output 2.51LEAC15224KZ Leat Continuous 1.5 metre, 2200lm Fixed Output 3.64LEAC20304KZ Leat Continuous 2 metre, 3000lm Fixed Output 4.69LEAC30454KZ Leat Continuous 3 metre, 4500lm Fixed Output 6.80ELLEAC10154KZ Leat Continuous 1 metre, 1500lm Fixed Output Emergency variant 2.80Medium output LEAC10224KZ Leat Continuous 1 metre, 2200lm Fixed Output 2.51LEAC15334KZ Leat Continuous 1.5 metre, 3300lm Fixed Output 3.64LEAC20444KZ Leat Continuous 2 metre, 4400lm Fixed Output 4.69LEAC30664KZ Leat Continuous 3 metre, 6600lm Fixed Output 6.80ELLEAC10224KZ Leat Continuous 1 metre, 2200lm Fixed Output Emergency variant 2.80 High output LEAC10304KZ Leat Continuous 1 metre, 3000lm Fixed Output 2.51LEAC15454KZ Leat Continuous 1.5 metre, 4500lm Fixed Output 3.64LEAC20604KZ Leat Continuous 2 metre, 6000lm Fixed Output 4.69LEAC30904KZ Leat Continuous 3 metre, 9000lm Fixed Output 6.80ELLEAC10304KZ Leat Continuous 1 metre, 3000lm Fixed Output Emergency variant 2.80 Continuous DALI For DALI Dimming option replace the character Z with DD, e.g. LEAC10304KZ becomes LEAC10304KDDDiffusers for Continuous modules LEAOP10Leat Continuous diffuser 1 metre0.10LEAOP15Leat Continuous diffuser 1.5 metre0.15LEAOP20Leat Continuous diffuser 2 metre 0.20LEAOP30Leat Continuous diffuser 3 metre 0.30LEAOP50Leat Continuous diffuser 5 metre 0.50LEAOP100Leat Continuous diffuser 10 metre 1.00LEAOP200Leat Continuous diffuser 20 metre 2.18LEAOP300Leat Continuous diffuser 30 metre 3.27LEAOP400Leat Continuous diffuser 40 metre 4.36LEAOP500Leat Continuous diffuser 50 metre 5.45Recessing frame LEARE10Recessing frame side rail kit 1 metre - set of 20.32LEARE15Recessing frame side rail kit 1.5 metre - set of 20.47LEARE20Recessing frame side rail kit 2 metre - set of 20.63LEARE30Recessing frame side rail kit 3 metre - set of 20.95LEAREETK Recessing frame end trim kit - set of 20.02LEAPL10Leat Recessed Mounting Bracket 1m0.45LEAPL15Leat Recessed Mounting Bracket 1.5m0.45LEAPL20Leat Recessed Mounting Bracket 2m0.45LEAPL30Leat Recessed Mounting Bracket 3m0.68Standalone Standalone Fixed OutputLow output LEAS10154KZ Leat Standalone 1 metre, 1500lm Fixed Output 2.46LEAS15224KZ Leat Standalone 1.5 metre, 2200lm Fixed Output 3.48LEAS20304KZ Leat Standalone 2 metre, 3000lm Fixed Output 4.51LEAS30454KZ Leat Standalone 3 metre, 4500lm Fixed Output 6.56ELLEAS10154KZ Leat Standalone 1 metre, 1500lm Fixed Output Emergency variant 2.75 Medium output LEAS10224KZ Leat Standalone 1 metre, 2200lm Fixed Output 2.46LEAS15334KZ Leat Standalone 1.5 metre, 3300lm Fixed Output 3.48LEAS20444KZ Leat Standalone 2 metre, 4400lm Fixed Output 4.51LEAS30664KZ Leat Standalone 3 metre, 6600lm Fixed Output 6.56ELLEAS10224KZ Leat Standalone 1 metre, 2200lm Fixed Output Emergency variant 2.75 High output LEAS10304KZ Leat Standalone 1 metre, 3000lm Fixed Output 2.46LEAS15454KZ Leat Standalone 1.5 metre, 4500lm Fixed Output 3.48LEAS20604KZ Leat Standalone 2 metre, 6000lm Fixed Output 4.51LEAS30904KZ Leat Standalone 3 metre, 9000lm Fixed Output 6.56ELLEAS10304KZ Leat Standalone 1 metre, 3000lm Fixed Output Emergency variant 2.75 Standalone DALI For DALI Dimming option replace the character Z with DD, e.g. LEAS10304KZ becomes LEAS10304KDD51AccessoriesPart No.DescriptionWeight (Kg)LEAEC Leat End Caps - set of 20.02LEA15SU Leat Suspension 1.5 metre - set of 20.09LEA50SU Leat Suspension 5 metre - set of 20.15LEAMC Leat Surface Mounting clips - set of 2 0.01LEADEKR Leat Diffuser expansion kit - Recessed0.10LEADEKSLeat Diffuser expansion kit - Surface / Suspended0.25Leat Corners - 100mm Leat Corners 100mmPart No.DescriptionWeight (Kg)LEA90CP Leat Corner, 100mm, 90 degrees with line design0.48Leat Corners are the latest accessory for the Leat luminaire, providing the option to create an elegant decorative feature. Available with an attractive design on the face of the corner or a minimalistic diffuser appearance, the corners provide a seamless aesthetic for any corner. Each corner is sold separately.Leat CornersLeat Corners - Dimensions534534Leat Corners - 500mmLeat Corners 500mmPart No.DescriptionWeight (Kg)LEA90CL10154KZ Leat Corner, 534x534mm, 90 degree, 1500lm 4k FO, diffuser design 2.51LEA90CL10224KZ Leat Corner, 534x534mm, 90 degree, 2200lm 4k FO, diffuser design 2.51LEA90CL10304KZ Leat Corner, 534x534mm, 90 degree, 3000lm 4k FO, diffuser design 2.51LEA90CL10154KDDLeat Corner, 534x534mm, 90 degree, 1500lm 4k DD, diffuser design2,51LEA90CL10224KDDLeat Corner, 534x534mm, 90 degree, 2200lm 4k DD, diffuser design2.51LEA90CL10304KDDLeat Corner, 534x534mm, 90 degree, 3000lm 4k DD, diffuser design2.51521Leat CornersEach corner is sold separately.Maximum length of 10 meters of any one side.Please note in an ‘L ’ configuration using ‘LEADEKS’, a maximum length of 25 meters per side can be used.For a guide to trimming the diffuser, please refer to the installation guide.Please note, the maximum length restrictions are the same for both the 100mm and 500mm versions in the configuration shown.Leat Corners - L ConfigurationLeat Corners - Configuration531。
Part Number Emitting Color Emitting MaterialLens-colorWavelength CIE127-2007*nm λPViewing Angle 2θ 1/2Luminous Intensity CIE127-2007* (I F =20mA) mcd *Luminous intensity value and wavelength are in accordance with CIE127-2007 standards.ATTENTIONOBSERVE PRECAUTIONSFOR HANDLING ELECTROSTATIC DISCHARGE SENSITIVE DEVICESESD-protected work areas to reduce static build up during assembly process (Reference JEDEC/JESD625-A and JEDEC/J-STD-033)Features● Ideal for indication light on hand held products ● Long life and robust package ● Standard Package: 2,000pcs/ Reel ● MSL (Moisture Sensitivity Level): 3 ● Halogen-free ● RoHS compliantLED is recommended for reflow soldering and soldering profile is shown below.Spatial DistributionThe device has a single mounting surface. The device must be mounted according to the specifications.Recommended Soldering Pattern (Units : mm; Tolerance: ± 0.1)Tape Specification (Units : mm)Remarks:If special sorting is required (e.g. binning based on forward voltage, Luminous intensity / luminous flux, or wavelength), the typical accuracy of the sorting process is as follows: 1. Wavelength: +/-1nm2. Luminous intensity / luminous flux: +/-15%3. Forward Voltage: +/-0.1VNote: Accuracy may depend on the sorting parameters.Reel Dimension (Units : mm)PACKING & LABEL SPECIFICATIONSTERMS OF USE1. Data presented in this document reflect statistical figures and should be treated as technical reference only.2. Contents within this document are subject to improvement and enhancement changes without notice.3. The product(s) in this document are designed to be operated within the electrical and environmental specifications indicated on the datasheet. User accepts full risk and responsibility when operating the product(s) beyond their intended specifications.4. The product(s) described in this document are intended for electronic applications in which a person’s life is not reliant upon the LED. Please consult with a SunLED representative for special applications where the LED may have a direct impact on a person’s life.5. The contents within this document may not be altered without prior consent by SunLED.6. Additional technical notes are available at https:///TechnicalNotes.asp。
LED软条灯产品说明书1.产品说明LED软灯条又名LED灯带,英文名称叫LED Strip,这个产品的形状就象一根带子一样,再加上产品的主要原件就是贴片LED。
颜色:红,黄,蓝,绿,白,暖白光工作电压:12V/24V灯珠分类SMD3528(贴片3528灯珠惯用于单色灯条SMD5050(贴片5050灯珠惯用于全彩红绿蓝灯条)以上两款产品为热销品种2.规格:3528每米30灯 DC 12V 1M≤2.4W3528每米60灯(常规) DC 12V 1M≤4.8W5050每米30灯 (常规) DC 12V 1M≤7.2W5050每米60灯 DC 24V 1M≤14.4W5050每米30灯七彩系例 DC 12V 1M≤7.2W5050每米30灯全彩系例 DC 24V 1M≤7.2W光源色温不同,光色也不同色温在3300K以下,光色偏红给以温暖的感觉;有稳重的气氛,温暖的感觉.,通称暖色温。
色温在 3000--6000K 为中间,人在此色调下无特别明显的视觉心理效果,有爽快的感觉;故称为 " 中性 " 色温色温超过 6000K ,光色偏蓝,给人以清冷的感觉,通称冷色温3、工艺类别NK---裸板(室内用)PU---滴胶(半防水,裸板滴硅胶,工艺稍复杂)PC---套管(防水,室外用,裸板套柔性硅胶防水管)PU+PC 实心套管滴胶(全防水,室外复杂环境工作)产品特性柔软灵活,特别方便于旮旯死角装饰,如圆形/不规则型设计的装饰灯带背面贴进口3M双面胶,套管系列配锁扣配件,安装方便LED产品寿命长,且低耗能4.使用及注意:本产品为恒流低压12V~24V,请接12V/24低压或购置变压开关电源,安装时,撕开产品背面双面胶粘于使用地点即可;RGB全彩系列,请购置配套RGB控制器便于遥控色彩(可设定单色/全白色或者遥控渐变,跳变并改变颜色变化速度…)本品常规使用时,建议并联;当串联使用时,连接长度请勿超过5米,以免电压不足导致亮度不够;使用说明:1、接线说明:红、黄、蓝、绿、白单色防水软光条:产品引出两根电源线,一根是红色,一根是黑色,导线线径是22AWG,长度是150MM。
规格尺寸与实物图:尺寸图实物图警告:无论任何情况下,灯具均不能直接安装在普通可燃材料表面。
警告:如果灯具的外部缆线损伤,该线要由制造商或其服务代理商或是有类似资格的人员更换,以避免发生危险。
警告:为防止灯具破损、坠落、触电、起火等威胁人身安全的事故发生,请严格按照说明书进行安装和使用,不能自行改迁和调换部件。
警告:贮存条件温度≤70°C、湿度10%-85%。
警告:安装前,必须切断电源,防止触电。
安装示意图:连接图:备注:1、灯具供电为DC 24V;2、进电处位于负荷中心(即中间进电往两边分);3、上下两个回路(电源)的灯具不连接在一起,悬空接头做防水处理;4、请选择适合的线径供电。
保养与维修:1、为了安全高效使用,建议每隔6个月请进行一次清洁,清洁灯具请使用柔软布料擦去污油,之后再用干布擦净即可,不要用其他清洁剂,否则将会导致灯具变色或损坏。
2、要灯具维护或更换时,请先切断电源,再维修。
注意:1、与本产品配套使用的电源及控制器须是我司认可的品牌和规格;2、灯具的安装人员需持有《电工证》,需有专业电气工程师指导施工;2、请根据本说明书接线原理图进行接线,合理选择线径和布线,避免压降过大;3、不得剪掉灯具原有防水接头,线长不够时,须用我司定制的带防水接头的延长线;4、注意轻拿轻放本灯具,不得拉扯灯具出线;5、未经我司允许不得拆开灯具;6、安装完成并检查合格后方可通电试灯,严禁带电操作;7、电源及控制器须安装于防水箱中,做好防水保护;8、灯具安装面必须防火,且安装面须能承载10倍以上灯具自重;9、未经我司允许,不得更换或取消灯具原安装支架和配件;10、供电电压必须与灯具输入电压匹配。
以上条款如有违反,我司概不负责。
防爆 LED 线性灯具EXLUX 6002/4 系列使用说明书其他语种 DEENFRITESRUNLDKSEFIPTGRPLCZSKHUSLROBGLVLTEECHKRCN内容目录2防爆 LED 线性灯具EXLUX 6002/4 系列内容目录1总体信息...............................................................................................................31.1制造商..................................................................................................................31.2使用说明书信息....................................................................................................31.3其他文档...............................................................................................................31.4标准和规定的符合性.............................................................................................32符号说明...............................................................................................................42.1本使用说明书中的符号.........................................................................................42.2警告提示...............................................................................................................42.3设备上的符号.......................................................................................................53安全提示...............................................................................................................53.1使用说明书的存放................................................................................................53.2安全使用...............................................................................................................53.3设计用途...............................................................................................................63.4改造和改装...........................................................................................................64功能和设备设计....................................................................................................64.1功能......................................................................................................................64.2设备设计...............................................................................................................75技术数据...............................................................................................................96运输和仓储.........................................................................................................157安装与装配.........................................................................................................157.1尺寸信息/固定尺寸...........................................................................................157.2去除保护膜.........................................................................................................177.3安装/拆卸,使用位置........................................................................................187.4装配....................................................................................................................218调试....................................................................................................................289维护、保养、修理..............................................................................................289.1维护和保养.........................................................................................................299.2修理....................................................................................................................299.3退回....................................................................................................................3010清洁....................................................................................................................3011废弃物处置 (3012)配件和备件 (31)286437 / 6002603002102023-05-16·BA00·III·zh·05总体信息3防爆 LED 线性灯具EXLUX 6002/4 系列1总体信息1.1制造商1.2使用说明书信息原版使用说明书是德语版。
1.产品简介E/CS-LK-00是公司出品的LED装饰照明灯具。
主要适用于建筑墙面、桥梁、橱窗、绿化等景观装饰照明。
E/CS-LK-00是可以在室内、户外安装的密封型灯具。
灯体采用压铸铝与挤压铝外壳,美观、耐腐蚀。
清晰钢化玻璃透光率高。
整体灯具外形美观整体灯具外形美观,防水、散热性能优秀。
采用高可靠散热设计,灯具更稳定,寿命更长久。
采用超亮度大功率LED光源。
灯具的恒流驱动线路保证光源的稳定工作。
灯具寿命可达到50000小时。
3.产品规格产品名称:LED全彩轮廓灯产品型号:E/CS-LK-12 产品型号:E/CS-LK-6电源电压:DC24V LED芯片颗数:48PCS LED芯片颗数:24PCS储存环境温度:-40℃至+85℃功率:Pmax=12W 功率:Pmax=6W灯具防护等级:IP65 工作环境温度:-20℃至+55℃工作环境温度:-20℃至+55℃防触电等级:Ⅲ类外型尺寸:L1000×W25×H15 (mm)外型尺寸:L1000×W25×H15(m m)4. 结构安装示意图所有安装必须由相关专业的人员完成。
(请妥善保管说明书等相关技术资料。
)1、将灯具支架安装在墙壁指定位置,用高强度螺栓锁紧(如上图)。
2、将灯具卡入支架内部,按照下图连接线路。
5.接线示意图6.常见故障处理中科宇泰E/CS-LK-12 LED线条灯使用说明书中科宇泰光能科技有限公司地址:南通市通州开发区杏园路299号电话:(0513)68856269传真:(0513)68856039。
CONSTRUCTIONInternal Rail Construction: Heavy duty extruded 6061-T6 Aluminum Alloy.External Rail Jacket: Available in 304 or 316stainless steel. Optional color finishes include silver, white, black, or bronze powder-coat. Consult factory for custom powder coat finishes (AAMA 2604).LED LIGHT SOURCE Closely packed array of small LEDs allow for smooth seamless illumination with immediate overlap to avoid pixilation and provide a continuous flow of light. Color temperatures options include 2700K, 3000K, 3500K or 4000K. ■85 CRI ■50,000 hours of average rated life at 70% output■LED components are easily accessible to allow for easy maintenance ■Maximum run length per driver: 8’ (HO)■Maximum run length per driver: 4’ (SHO)LED LIGHT ENGINE (PER FOOT):High Output■System Power Consumption: 4.6W■Cool White 4000K: 241 lm ■Neutral White 3500K: 207 lm■Warm White 3000K: 202 lm ■Warm White 2700K: 197 lm Super High Output (Integral driver required on each post) ■System Power Consumption: 9.2W■Cool White 4000K: 483 lm ■Neutral White 3500K: 415 lm ■Warm White 3000K: 404 lm ■Warm White 2700K: 395 lmLIGHT DISTRIBUTION & OUTPUTThe V-Rail optical system includes a unique reflector that allows you to put the light where it is needed. Factory preset distributions include 60° symmetric, 20° symmetric and 30° asymmetric.OPTICAL LENS SYSTEMHigh-impact acrylic lens is sealed with silicon. Lens is secured with (2) countersunk flush screws, (1) at each end. Vandal resistant “TORX” is also available. Consult factory.REFLECTOR SYSTEMInternal reflector system is constructed of aninnovative material that has 99% reflectance properties. Reflector allows up to 140° total adjustment. Right to left side reflector panels are independently adjustable from -30° to 70°. When the outer reflector panel is adjusted toward a stairway, ramp or walkway, the reflector panel will act as a glare shield from distant viewing angles below anelevated platform.MOUNTING / INSTALLATIONEach rail support is secured to the swivel mount on specified mounting system. Post or embedded mountis available. See mounting submittal sheets fordetailed information.EMERGENCY Remote emergency inverter available. Can be remoteup to 1000 ft. See IB-IIS specification sheet.LISTINGS ■5-Year Intense LED Limited Warranty (LED & Power Supply Only)■UL Wet Location Listed. File #E333075 ■IDA approved ■ADA compliantU.S. Patent # D615,217S issuedOther patents pending60” and a minimum of 24”Exact decimal and common fraction is shown1.90” 7/8” )PHOTOMETRIC DATA ■LED: 4.6W High Output ■CCT: 4000K■Illuminated Rail Length: 41” ■Rail Height: 36” ■Post Spacing: 48”60° Flood20° Narrow30° Asymmetrical1’252526272610101010103’101010101025252626271’2’171718181818181818182’3’1’1818191919444443’3’4444418181919191’2’88999889992’1’121212121214141515153’3’2222229293130311’2’5555523232424242’JOB NAME CATALOG NUMBER NOTESTYPEPost SpecificationB4 1/2”Post Mount Installation DetailCONSTRUCTIONPost mount assembly is available in heavy duty steel alloy or No.4 polished 304 stainless steel. Optional color finishes include silver, white, black, or bronze powder-coat. Consult factory for custom powder coat finishes (AAMA 2604).MAINTENANCEPosts include a driver access door where power supply components are easily accessible. Tamper proof hardware and special tools are standard and included.MOUNTING / INSTALLATIONPost are to be spaced at a maximum of 60” and minimum of 24” on centers. Post mount is to be surface mounted to concrete utilizing 3/8” anchor bolts (supplied by others). Anchoring means must be determined by local codes. Not to be supplied or engineered by Intense Lighting. See post mount installation chart for more information. Anchorage template available by request.OPERATIONPost with integral power supply will power up-to 83 1/2” of illuminated rail. High output LED only. Super high output not available.FITTINGSConsult factory for standard fittings and epoxy weld adhesive specification.Level PostGrout as required to level posts for uneven or grades not levelElectrical 1/2” conduit (max) Stub-up, In and out access (by others) 6” above grade.IMPORTANT:Seal end of conduit with good grade RTV to prevent moisture entering compartmentAnchors supplied and approved by others.Service Bay OpeningLED Power SupplyOutput (24V DC)Note:Conduit feed only required when installing post with integral power supply. Typically every other post will require conduit feed.AMounting ScrewAC Input Mounting Screw2” OD 1.844” ID(Max angle)35°BASE SPECIFICATION3x Ø0.43Ø3.55Ø4.5”DIMENSIONSGuardrail Handrail A 17”14”B42”36”Grade Level6” (TVP)*Notify Intense Lighting if other embedment dimension required.B2” OD (Max angle)Post SpecificationEmbedded Installation DetailLevel PostConcrete (by others)IMPORTANT:Seal end of conduit with good grade RTV to prevent moistureentering compartmentField wiring connects to internal terminal block.Rockite ® Anchor Cement (or equal)6” Burial Depth*Note:Conduit feed only required when installing post with integral power supply. Typically every other post will require conduit feed.*Cored hole dimensions to be determined by others per local codes.Electrical 1/2” conduit (max) Stub-up, In and out access (by others) 6” above grade.CONSTRUCTIONEmbedded mount assembly is available in heavy duty steel alloy or No.4 polished 304 stainless steel. Optional color finishes include silver, white, black, or bronze powder-coat. Consult factory for custom powdercoat finishes(AAMA 2604).MAINTENANCEPosts include a driver access door where power supply components are easily accessible. Tamper proof hardware and special tools are standard and included.MOUNTING / INSTALLATIONPost are to be spaced at a maximum of 60” and minimum of 24” on centers. Embedded mount post are set into place using Rockite ® or Kwixset ® anchor cement. A minimum of 6” post must be embedded into concrete to structurally secure post. Anchoring means must be determined by local codes. Not to be supplied or engineered by Intense Lighting. See Embedded Mount Installation chart for more information.OPERATIONPost with integral power supply will power up-to 83 1/2” of illuminated rail. High output LED only. Super high output not available.FITTINGSConsult factory for standard fittings and epoxy weld adhesive specification.AService Bay OpeningLED Power SupplyOutput (24V DC)Mounting ScrewAC Input Mounting Screw35°1.844” IDDIMENSIONSGuardrail Handrail A 17”14”B42”36”IVR2-SPI1.9” Solid State Illuminated Rail Specification GuideNotes:Completed ProjectSpecification and Delivery Process will provide detailed shop drawings for approval.Notes:1. 316 Stainless steel available by special order2. Special order, consult factory3. Integral driver required on each postV-Rail Part Number(Example: IVR2-SPI-ST-P36-HO27-60S-EM)(Specify Quantity By Foot)A: Family B: Finish C: Mounting/Height D: LED Output E: CCT F: Light Distribution G: Electrical H: OptionsIVR2-SPI-ST-W-B-BR-SV-C (304 Stainless Steel)1(White)(Black)(Bronze)(Silver)(Custom)2-P36-P42-E36-E42(36” Post Mount)(42” Post Mount)(36” Embedded Mount)(42”Embedded Mount)-HO-SHO(High Output)(Super High Output)327303540(2700K)(3000K)(3500K)(4000K)-60S-20S-30AS(60° Symmetric)(20° Symmetric)(30° Asymmetric)blank-LUT2ERP VLM Series120/277V Input DriverLutron LTEA 2-Wire 1%Dim 120V Input Driver-I(Infill)2JOBNAMECATALOGNUMBERNOTES TYPE。
CONSTRUCTIONHeavy gauge square extruded aluminum housing. ¼” thick precision-machined aluminum end-caps. Extruded acrylic lenses specifically engineered to maximize the performance and transmission from a variety of light sources.LED LIGHT OUTPUT SYSTEM■HLO (High Lumen Output) & SLO (Standard Lumen Output) providing efficient illumination.■CLO (Custom Lumen Output) User specified lumen output & wattage. Consult factory for details.■Rated life of L70 > 60,000 hours based on LED testing per LM-80-08 and projected values using IESNA TM21-11DIMMING■0-10V Dimming 1%■eldoLED 0-10V 0.1% or 1%■Lutron ® LTEA2W Hi-Lume 2-Wire 1% ■Lutron ® LDE1 Hi-Lume EcoSystem 1% ■DALI Dimming 1%LENS■Impact resistant co-extruded lens with highly reflective internal cavity■(HE) High Efficiency lens provides optimal performance with even and continuous diffusion■(FBLSS) Flat Blade Louver Semi-Specular with diffusing layerPERFORMANCE OPTICS(BW) Batwing, (AS) 15° Asymmetric, and (E70) 70° Elliptical.FIXTURE LENGTH■Nominal Lengths: 2’, 3', 4’, 6', and 8’■Continuous run & mitered angles available. Consult factory for lead times.MOUNTING■ Surface Mount (SM) to wall or ceilingFINISHESAvailable finishes includes powder coated Matte White (MW), Flat Black (FB), and Matte Aluminum (MA). Consult factory for custom powder coat finishes.LISTING / WARRANTY ■5-Year Limited Warranty■UL Listed to US and Canadian standards■Can be used to comply with 2016 Title 24, Part 6, JA8 high efficacy LED light source requirements 111: Model2: Light Output 3: CCT / CRI 4: Nominal Length 5: Finish6: Lens KEL-LED-225-IB KEL-LED-225-RB (2.25", Integral Driver)(2.25", Remote Driver)-SLO -HLO -CLO2(StandardLumen Output)(High LumenOutput)(Custom LumenOutput)-279-30-309-35-359-40-409(2700K / 90CRI)(3000K / 80CRI)(3000K / 90CRI)(3500K / 80CRI)(3500K / 90CRI)(4000K / 80CRI)(4000K / 90CRI)-2-3-4-6-8-CR_3-MTR-R4(2ft)(3ft)(4ft)(6ft)(8ft)(Continuous Run)(Miter Run)-MW -FB -MA -CUP5(Matte White,Powder Coat)(Flat Black,Powder Coat)(Matte Aluminum,Powder Coat)(Custom PowderCoat)-FW -HE 6-RLW-BW 6-AS 6-E706-FBLSS (Frosted White)(High Efficiency)(Reveal Frosted White 3/8 Extended)(Batwing 115°)(Asymmetric 15°)(Elliptical 70°)(Flat Blade Louver Semi-Specular)ORDERING CODE: (Example: KEL-LED-225-IB-SLO-30-2-MW-FW-120-D1-SM )12345678910117: Voltage 8: Driver9: Mounting Options 11: Options-120-277-3472(120V)(277V)(347V)-D1-ED10V1-ED10V01-HLA27-HL -DALI (0-10V Dimming 1%)(eldoLED 0-10V 1%)(eldoLED 0-10V 0.1%)(LTEA2W Lutron Hi-Lume 2-Wire 1%)(LDE1 Lutron Hi-Lume Ecosystem 1%)(DALI Dimming 1%)-SM (Surface Mount)-EM5-IEPH1(Emergency Battery Pack)(Leviton Intellect Embedded Integral Sensor & Power Pack)Notes1. -D1 (0-10V 1%) only. Excludes 80CRI, Remote Driver and Continuous Runs2. Consult factory, available with D1 options only3. Specify length in "feet"4. See miter worksheet for specification (detailed drawing required)5. Consult factory6. Available with 225 RB only7. Lutron HLA2, 120V onlyOptions in green qualify for the 10 day shipping program. Refer to the 10 day shipping guide for more details.DIMENSIONS:Surface Mount OptionsDIMENSIONS:Standard Nominal Length: 2, 3, 4, 6, or 8-foot(Consult factory for custom lengths)Frosted WhiteBeam: 105°Elliptical (E70)Beam: 70°High Efficiency (HE) Beam: 105°Batwing (BW)Beam: 125°Asymmetric (AS)Beam: 15°。
Remove the fixture from its original packaging1. Separate the mounting plate (1c) from the canopy (2a) by removing the canopy screws (2c)Attach the mounting plate (1c) to the electrical junction box (1a) using the two screws (1d) provided in the hardware package2. 3. Make proper electrical connections (black to hot “L”, white to neutral “N”, ground to “GND”) with wire nuts (1b) provided in hardware package4. Attach canopy (2a) to mounting plate (1c) with canopy screws (2c)5. Mark and install ceiling anchors (3b) with screw (3a), opening on ceiling anchor (3b) facing towards canopy (2a). Ideal distance between ceiling anchors (3b) is 46-5/16”.6. Place wire onto pulley (3g), insert into ceiling anchor (3b) and secure with screw (3f)7. Fine tone wire length if necessary, by push and hold wire gripper (2g) and then adjust wire to desired length8.Disconnect output wires on driver (2f)FOR ALTERNATIVE SIDE CANOPY INSTALL1.Move wire gripper (2g) to bottom of the canopy,secure with nut (2d), and close holes on side of canopy with plugs (2e)Reconnect driver positive wire to center core of hangingcable, and negative to meshed conductor2. 3. 4. Attach canopy (2a) to mounting plate (1c) with canopyscrews (2c). Position desired amount of wire by pushing gripper (2g) on canopy (2a)5.(2g) and then adjust wire to desired length6.Pull wire through aircraft barrel (4b) and stopper (4d)aircraft barrel (4b) to mounting surface with anchor (4c) and screw (4a). Adjust wire to desired length and secure with setscrew (4e). Insert wire gripper (2g) into aircraft barrel (4b)。